AppNote 8/2012. Rapid Automated Extraction and Confi rmation of Buprenorphine and Norbuprenorphine in Urine by DPX-LC/MS/MS KEYWORDS ABSTRACT

Similar documents
AppNote 1/2013. Determination of Barbiturates and 11-Nor-9-carboxy- 9 -THC in Urine using Automated Disposable Pipette Extraction (DPX) and LC/MS/MS

AppNote 2/2013. A High Throughput Automated Sample Preparation and Analysis Workfl ow for Comprehensive Toxicology Urine Screenings using LC/MS/MS

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

AppNote 7/2014. Automating Liquid-Liquid Extractions using a Bench-top Workstation KEYWORDS ABSTRACT. Sample Preparation, Lab Automation, LC/MS/MS

AppNote 8/2008. A New Purge Tool for Use with Automated Headspace Analysis KEYWORDS ABSTRACT

AppNote 6/2004. Thermal Desorption GC Analysis of High Boiling, High Molecular Weight Hydrocarbons SUMMARY

AppNote 6/2014. Automated Online Desorption and Analysis of DNPH Derivatives of Airborne Aldehydes and Ketones KEYWORDS ABSTRACT

AppNote 14/2012. Thermal Gravimetric Analysis/Mass Spectrometry Simulation using the GERSTEL Automated Pyrolyzer KEYWORDS ABSTRACT

AppNote 4/2008. Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps KEYWORDS ABSTRACT

AromaOffi ce: Application of a Novel Linear Retention Indices Database to a Complex Hop Essential Oil

AppNote 3/2007 KEYWORDS INTRODUCTION. Beverage, Detector, Headspace, Quality Control

AppNote 7/2003. Coupling Retention Time Locked Methods and Libraries to Automated SPME or SBSE for Analysis of Flavors and Fragrances KEYWORDS

AppNote 4/1998. New Developments in Multi-Dimensional Capillary Gas Chromatography KEYWORDS ABSTRACT

AppNote 15/2012. Large Volume Injection with Solvent Venting - Application to Trace Detection of Analytes in Water INTRODUCTION

AppNote 5/2002. Characterization of a Mass Spectrometer based Electronic Nose for Routine Quality Control Measurements of Flavors KEYWORDS ABSTRACT

AppNote 2/2002. Discrimination of Soft Drinks using a Chemical Sensor and Principal Component Analysis KEYWORDS ABSTRACT

AppNote 3/2014. Analysis of Aroma Compounds in Edible Oils by Direct Thermal Desorption GC/MS using Slitted Microvials KEYWORDS ABSTRACT

TechNote 5/2002 KEYWORDS ABSTRACT. SBSE, Twister, Thermal Desorption

AppNote 8/2002 KEYWORDS ABSTRACT. Electronic Nose, Fast GC, Headspace Analysis, Chemometrics,

AppNote 6/2010. part a. Alternative Procedure for Extraction and Analysis of PAHs in Seafood by QuEChERS-SBSE-GC-MS KEYWORDS ABSTRACT

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to En vi ron men tal Aqueous Samples INTRODUCTION

AppNote 1/2007. Automated Dynamic Headspace Sampling using Replaceable Sorbent Traps KEYWORDS ABSTRACT

AppNote 2/2007. Automated Solid Phase Microextraction using the GERSTEL MPS Prepstation and MAESTRO Software KEYWORDS ABSTRACT

Off-gassing of Rubber Particles Used for Athletic Fields using Automated Dynamic Headspace Sampling

AppNote 2/1996. Andreas Hoffmann Gerstel GmbH & Co.KG, Eberhard-Gerstel-Platz 1, D Mülheim an der Ruhr, Germany

AppNote 10/2012. Large Volume Injection with GC/MS Multi Column Switching for Direct Determination of Ethyl Carbamate in Alcoholic Beverages KEYWORDS

AppNote 1/2004. Use of a Mass Spectral Based Chemical Sensor to Discriminate Food and Beverage Samples: Olive Oils and Wine as Examples KEYWORDS

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

AppNote 5/2001. The Analysis of the Bitter and Other Flavour Compounds in Beer and Wort by Stir Bar Sorptive Extraction (SBSE) Followed by HPLC

AppNote 8/2009. Fragrance Profi ling of Consumer Products using a Fully Automated Dynamic Headspace System KEYWORDS ABSTRACT

Analysis of Food Samples using Thin Film Solid Phase Microextraction (TF-SPME) and Thermal Desorption GC/MS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

AppNote 7/2002. Classifi cation of Food and Flavor Samples using a Chemical Sensor KEYWORDS ABSTRACT

AppNote 2/2004. Analysis of Packaging Materials using a Mass Spectral Based Chemical Sensor KEYWORDS ABSTRACT

AppNote 3/2012. Rapid Automated Screening of Extractable Compounds in Materials for Food Packaging, Medical or Technical Purposes KEYWORDS ABSTRACT

AppNote 2/2001. Stir Bar Sorptive Extraction: Enhancing Selectivity of the PDMS Phase KEYWORDS ABSTRACT

Thermal Desorption Unit TDU

AppNote 11/2012. Fully Automated Analysis of Doping Substances in Equine Urine by Disposable Pipette Extraction (DPX) coupled to GC/QqQ-MS KEYWORDS

AppNote 6/2012. Flavor and Fragrance Analysis of Consumer Products - Dynamic Headspace Compared to Some Traditional Analysis Approaches KEYWORDS

GERSTEL MultiPurpose Sampler MPS. Versatile autosampler and sample preparation robot

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

AppNote 2/2012. Determining Phenolic Compounds in Whisky using Direct Large Volume Injection and Stir Bar Sorptive Extraction KEYWORDS ABSTRACT

AppNote 4/2005. A Selectable Single or Multidimensional. Fraction Collection and Dual Detection for Trace Analysis of Complex Samples KEYWORDS

AppNote 8/2000. Volatile Organic Compounds from Adhesives and their Contribution to Indoor Air Problems KEY WORDS ABSTRACT

AppNote 1/2011 KEYWORDS ABSTRACT

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

AppNote 12/2008 KEYWORDS ABSTRACT

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

AppNote 2/1998. Direct Injection of Distilled Spirits with PTV Matrix Removal: The Perfect Splitless Injection? KEYWORDS INTRODUCTION

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

AppNote 9/2012. Solid Phase Micro-Extraction (SPME) Coupled with Selectable 1 D/ 2 D GC-MS for the Determination of Food Product Flavors KEYWORDS

KEYWORDS ABSTRACT AppNote 6/2002

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

AppNote 12/2012. Comparison of EG-Silicone-SBSE and Derivatization-PDMS-SBSE for the Analysis of Phenolic Compounds and Off-fl avors in Water KEYWORDS

AppNote 7/2013. Comprehensive Automation of the SPE- GC/MS Analysis of Opioids, Cocaine and Metabolites from Serum and Other Matrices KEYWORDS

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

AppNote 8/2011 KEYWORDS ABSTRACT INTRODUCTION

AppNote 7/2005. Detection of Packaging Emissions using a Flexible Headspace Sampler Combined with a Multi Sensor System and a Separation Unit KEYWORDS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Abstract. Experimental Sample Preparation

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Quad-Z 215 with Disposable Tips: Implementing the Use of ZipTips for the Purification of Biological Samples

AppNote 5/1994. The Use of a Multi Purpose Sampler for Headspace GC-MS Analysis of Volatile Organic Compounds in Human Urine

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

AppNote 3/1998 KEYWORDS ABSTRACT. Beverage, Food & Flavor, PTV, Large Volume Injection, Headspace, Thermal Desorption.

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Selective Sample Enrichment of Gaseous Samples using a Cooled Injection System: Trace Determination of Sulphur Components in Natural Gas

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Detection of 9-tetrahydrocannabinol ( 9-THC) in human urine by Solid Phase Extraction and HPLC.

Analysis of Propofol (2,6-Diisopropylphenol) and its Metabolites in One Injection using the DuoSpray Ion Source

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Analysis of Cannabinoids and Amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source. Application.

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Determination of Tetrafluoroborate, Perchlorate, and Hexafluorophosphate in a Simulated Electrolyte Sample from Lithium Ion Battery Production

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

AppNote 6/2010. part b. High Throughput Method for the Determination of PAHs in Seafood by QuEChERS-SBSE-GC-MS SCOPE PRINCIPLE

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Bioanalytical Chem: 4590: LC-MSMS of analgesics LC-MS Experiment Liquid Chromatography Mass Spectrometry (LC/MS)

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

Screening of pesticides in water using SPE on line

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

NORBUPRENORPHINE (Buprenorphine s Metabolite ) BUPRENORPHINE in urine by GC/MS Code GC Method of Confirmation by GC-MS

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

Transcription:

AppNote 8/2012 Rapid Automated Extraction and Confi rmation of Buprenorphine and Norbuprenorphine in Urine by DPX-LC/MS/MS Oscar G. Cabrices, Fred D. Foster, Edward A. Pfannkoch Gerstel, Inc., 701 Digital Dr. Suite J, Linthicum, MD 21090, USA KEYWORDS DPX, LC/MS/MS, Sample Preparation, High Throughput Lab Automation ABSTRACT This study focuses on the rapid cleanup of urine samples (< 500 μl) using disposable pipette extraction (DPX) for high throughput LC/MS/MS screening of buprenorphine (Bup) and main active metabolite norbuprenorphine (Nbup). Using a GERSTEL MultiPurpose Sampler (MPS), DPX extractions of hydrolyzed urine were performed, and analysis results were directly compared to results obtained using the dilute-and-shoot (D&S) approach for the same samples. The automated DPX cleanup process significantly reduced matrix effects without compromising the required minimum reportable limits (MRLs), whereas when using the D&S approach, samples had to be diluted by up to a factor 100 to remove such effects, which directly affected the ability to determine Bup and Nbup at the MRLs. Moreover, the addition of valve switching control from MAESTRO software further increased the throughput potential of the solution. The resulting eluents from the automated DPX extractions were injected into an Agilent 6460 LC/MS/MS instrument configured with 2 LC pumps (Gradient and re-generative) allowing rapid, just-in-time sample preparation for high throughput screening, averaging a cycle time of 4 min/sample.

INTRODUCTION The continuously growing list of pain management (PM) drugs has increased the demand for more reliable solutions to monitor compliance in connection with substance abuse and/or diversion. The recent adaptation of LC/MS/MS technology for PM drug monitoring has been successful due to its high sensitivity, excellent selectivity, the small sample volume required, low detection limits (e.g., 1 ng/ml), and since there is no need for chemical derivatization of analytes. However, the appearance of a new generation of highly sensitive analytical instrumentation in the market allegedly has brought promises of being able to eliminate conventional sample preparation, leading users toward easy dilute-and-shoot (D&S) strategies. Although the D&S approach is rapid and straightforward, endogenous matrix components (e.g., organic acids, bile salts) are not removed, directly affecting the performance of the system and the quality of the results. Traditional sample preparation techniques such as SPE, SLE, and LLE enable matrix elimination and selective analyte concentration to ensure accurate PM drug analysis. In this study, a one step matrix removal approach was used to isolate buprenorphine (Bup) and main active metabolite norbuprenorphine (Nbup) using Disposable Pipette Extraction (DPX). DPX is a novel dispersive solid-phase extraction technique based on a patented device that incorporates sorbent loosely contained in a pipette tip enabling it to efficiently mix with the sample solution. The main advantages of DPX technology are: rapid extraction, high recovery, negligible generation of solvent waste, and fully automated extraction combined with introduction to the chromatography system. We have adapted our original DPX urine cleanup method for comprehensive screening of PM drugs [1], to target parent drug-metabolite panels (i.e., Bup and Nbup) for high-throughput just in time sample preparation and analysis using a GERSTEL MultiPurpose Sampler (MPS XL) connected to an LC/MS/MS system. The different DPX extraction sorbents (DPX-RP-S and DPX-WAX-S) used in this method provide high extraction efficiency and enable the removal of salts and proteins present in urine resulting in reduced matrix effects compared with the D&S approach. The addition of valve switching control and an extra LC column combined with the automated sample preparation procedure further increases the throughput potential, allowing cycle times of 4 min/sample. EXPERIMENTAL Materials. Bup and Nbup stock solutions and deuterated analogues were purchased from Cerilliant. An intermediate analyte mixture stock solution was prepared by combining the analyte stock solutions with acetonitrile, at appropriate concentrations. ß-Glucuronidase, Type-2, from Helix pomatia, (cat.#g0876-5ml) was purchased from Sigma-Aldrich. Fresh urine was obtained from a male volunteer. All other reagents and solvents used were reagent grade. Instrumentation. All automated DPX PrepSequences were performed using a dual-head MultiPurpose Sampler (MPS XL) fitted with the GERSTEL DPX option as shown in Figure 1. All analyses were performed using two Agilent 1200 series HPLC pumps, an Agilent 6460 Triple Quadrupole Mass Spectrometer with Jet stream electrospray source and GERSTEL MPS XL configured with Active Washstation. Sample injections were made using a 6 port (0.25mm) Cheminert C2V injection valve fitted with a 2 μl stainless steel sample loop. A switching 10 port (0.40 mm) Cheminert C2H valve was configured with two Zorbax Eclipse Plus C18 columns (2.1 x 50 mm, 1.8 μm, 600 bar). Figure 1. MPS 2XL multi-purpose sampler with the GERSTEL DPX option for high throughput pain management drug screening. AN/2012/8-2

Sample pretreatment. Hydrolysis of urine was performed by combining 2 ml of urine, 150 μl of the working internal standard solution, 100 μl of ß-Glucuronidase, and 500 μl of 0.66 M acetate buffer, ph 4, vortex mixing for 30 seconds, and then incubating at 55 C for 2 hours. Aliquots of 260 μl of hydrolyzed urine samples were transferred to clean shell vials for automated cleanup and injection. For D&S samples two different dilution strategies were chosen: a) 1:10 dilution ratio, commonly used in urine assays [2]. B) 1:100 dilution ratios, shown to work with high-end MS detectors and previously shown to significantly minimize matrix effects [3] Figure 2 shows a graphical representation of the general DPX cleanup process. The automated DPX extraction used for this method consisted of the following steps: Automated DPX Prep Sequence - DPX Cleanup procedure 1. Aspirate 750 μl of 100 % acetonitrile from the fast solvent delivery station using the 2.5 ml DPX syringe. 2. Pick up a new DPX tip from the tray. 3. Dispense 500 μl of 100 % acetonitrile through the DPX tip, into the urine sample located on the MPS sample tray. 4. Wait for 6 seconds to allow the acetonitrile to completely wet the DPX sorbent. 5. Aspirate the entire sample followed by 1400 μl of air into DPX tip. 6. After equilibrating for 5 seconds, dispense the contents of the DPX tip, as well as the remaining acetonitrile found within the DPX syringe, back into the original shell vial in the tray. 7. Move the DPX tip to the PipWaste position and dispose of the DPX tip. 8. Inject 10 μl of the sample into the HPLC injection valve. 9. Trigger valve to switch flow for column regeneration. Figure 2. Graphical representation of the automated DPX urine cleanup process. Analysis conditions LC. Pump: gradient (600 bar), flowrate = 0.5 ml/min Mobile Phase: A - 5 mm ammonium formate, with 0.05 % formic acid B 0.05 % formic acid in methanol Gradient: Initial 5 % B 0.25 min 5 % B 2.5 min 95 % B Regeneration: Initial 95 % B 1.0min 95 % B 1.25 min 5 % B 2.5 min 5 % B Inj. volume: 2 μl (loop over-fill technique) Column temperature: 25 C Analysis conditions MS. Operation: electrospray positive mode Gas temperature: 350 C Gas flow (N2): 12 L/min Nebulizer pressure: 35 psi Capillary voltage: 4400 V AN/2012/8-3

RESULTS AND DISCUSSION Recovery Studies. Recovery studies were performed to evaluate the extraction efficiency of different DPX sorbents for targeted parent drug-metabolite panels. Two different sorbents were evaluated: a) Reversed Phase (DPX-RP-S) and b) weak anion exchange (DPX- WAX-S). Table 1 lists the absolute recoveries and % s for Bup and Nbup with both extraction sorbents. The DPX-WAX-S cleanup method was slightly more effective in removing urine matrix interferences and selective for the targeted compounds yielding recoveries above 90 %. Table 1. Absolute Recovery percentages for the different DPX sorbents used in this study. Compound DPX-RP-S DPX-WAX-S Matrix Effect Studies. Matrix effects were studied by injection of matrix-matched standards to create calibration curves using: a) samples extracted with DPX and b) D&S samples with different dilution factors (1:10 and 1:100). The matrix-matched calibrations were directly compared to neat standard curves in pure solvent. Matrix suppression/enhancement was determined by the ratio of matrix-matched and solvent-only calibration curve slopes. A value of 1.0 for the ratio of two standard curve slopes means there is no matrix effect, while positive deviations from 1.0 indicate enhancement and negative deviations indicate suppression. Table 2 shows the average slope ratios (n=3) and % s for the matrix effects of DPX vs. D&S. The commonly used 1:10 dilution strategy resulted in a significant matrix enhancement effect for Bup and Nbup in comparison to the DPX cleanup method (Figure 3). This effect can be attributed to the high content of salts and organic acids in the injected matrix. The % s for the DPX cleanup approach were lower (1-3 %) showing better reproducibility than the D&S samples (5-6 %). Rec. Rec. Buprenorphine 90.57 0.96 94.21 0.96 Norbuprenorphine 88.06 2.38 91.47 2.76 Table 2. Average calibration slope ratios and % s indicating the matrix effects seen when using D&S vs. DPX(n=3). Compound Matrix Effects DPX-RP-S DPX-WAX-S D&S (1:10) D&S (1:100) Matrix Effects Matrix Effects Matrix Effects Buprenorphine 0.93 1.36 0.94 2.66 1.70 6.22 0.90 5.78 Norbuprenorphine 0.99 2.74 1.00 3.53 1.39 6.18 0.90 4.59 Figure 3. Matrix effect percentages resulting from DPX and D&S strategies. AN/2012/8-4

The advised maximum 1:100 dilution strategy significantly reduced matrix effects in comparison to the common D&S tactic. However, when using such a large dilution factor and a 6460 LC/MS/MS system, the MRLs for Bup and Nbup could not be achieved, as shown in Figure 4. Figure 4. Overlaid calibration plots for DPX and D&S based analysis methods. Column switching for high throughput analysis. Figure 5 shows a dual column valve configuration for high throughput analysis of Bup and Nbup. With a single column configuration and automated DPX prep sequence, a 6 min/sample cycle time is achieved, enabling the user to process over 240 samples per day. By integrating valve switching capabilities and bringing a second conditioned column online, which can be used while the first column is being regenerated and vice versa, the cycle time was reduced to approximately 4 min/sample providing the ability to process over 350 samples in 24 hours. Figure 6 shows chromatograms of extracted urine samples obtained using the dual column configuration. Figure 5. Dual Column configuration. AN/2012/8-5

Figure 6. Chromatograms for Bup and Nbup in extracted urine samples using column switching. CONCLUSIONS As a result of this study, we were able to show: The automated urine cleanup method performed using the Dual Head GERSTEL MPS XL combined with and DPX-WAX-S sorbent provides high extraction efficiency (> 90 % recovery) for Buprenorphine and Norbuprenorphine. The same DPX cleanup method could be used for the extraction and determination of other targeted PM drug-metabolite panels. The DPX cleanup method showed minimal matrix effects, whereas typical D&S samples gave up to 70 % matrix enhancement effects. To minimize this effect a dilution factor of 1:100 was used, but it was not possible to achieve MRLs for the targeted compounds using the Agilent 6460 TripleQuad LC/MS By adding a second column to the DPX-LC/MS/ MS system and using valve switching, a cycle time of approximately 4 min/sample enables the processing over 350 samples in 24 hrs. REFERENCES [1] Rapid cleanup and comprehensive screening of pain management drugs in urine using automated disposable pipette extraction and LC/MS/MS Gerstel AppNote AN-2012-01 [2] A Comparative Study of Common Urine Sample Preparation Techniques of a Comprehensive Panel of Pain Management Drugs by LC/MS Analysis for Forensic Toxicology Poster # 2 MSACL 2012 [3] Ferrer, C.; Lozano, A.; Agüera A.; Giron A.J.; Fernandez-Alba A.R.; J Chromatogr A, 1218, (2011) p. 7634-7639. For research use only. Not for use in diagnostic procedures. The information provided for this product is intended for reference and research purposes only. GERSTEL offers no guarantee as to the quality and suitability of this data for your specific application. Information, descriptions and specifications in this publication are subject to change without notice. AN/2012/8-6

AN/2012/8-7

GERSTEL GmbH & Co. KG Eberhard-Gerstel-Platz 1 45473 Mülheim an der Ruhr Germany +49 (0) 208-7 65 03-0 +49 (0) 208-7 65 03 33 gerstel@gerstel.com www.gerstel.com GERSTEL Worldwide GERSTEL, Inc. 701 Digital Drive, Suite J Linthicum, MD 21090 USA +1 (410) 247 5885 +1 (410) 247 5887 sales@gerstelus.com www.gerstelus.com GERSTEL AG Wassergrabe 27 CH-6210 Sursee Switzerland +41 (41) 9 21 97 23 gerstelag@ch.gerstel.com www.gerstel.ch GERSTEL K.K. 1-3-1 Nakane, Meguro-ku Tokyo 152-0031 SMBC Toritsudai Ekimae Bldg 4F Japan +81 3 5731 5321 +81 3 5731 5322 info@gerstel.co.jp www.gerstel.co.jp GERSTEL LLP Level 25, North Tower One Raffles Quay Singapore 048583 +65 6622 5486 +65 6622 5999 SEA@gerstel.com www.gerstel.com GERSTEL Brasil Av. Pascoal da Rocha Falcão, 367 04785-000 São Paulo - SP Brasil +55 (11)5665-8931 +55 (11)5666-9084 gerstel-brasil@gerstel.com www.gerstel.com.br Information, descriptions and specifications in this Publication are subject to change without notice. GERSTEL, GRAPHPACK and TWISTER are registered trademarks of GERSTEL GmbH & Co. KG. Copyright by GERSTEL GmbH & Co. KG Awarded for the active pursuit of environmental sustainability