Workshop on Biomedical Applications of High Energy Ion Beams

Similar documents
The scanning microbeam PIXE analysis facility at NIRS

Irradiation of Living Cells with Single Ions at the Ion Microprobe SNAKE

COST MP0601 Short Wavelength Laboratory Sources

The heavy ion irradiation facility at KVI-CART

A single-particle/single-cell microbeam based on an isotopic alpha source

Examples for experiments that can be done at the T9 beam line

Radiation Protection Dosimetry Advance Access published December 21, 2006

object objective lens eyepiece lens

Screens for low current beams

Energy Dependence of Biological Systems Under Radiation Exposure

The accelerators at LNS - INFN and diagnostics aspects of the radioactive beams

Metallic nanoparticles in proton therapy: how does it work? Dr. Anne-Catherine Heuskin University of Namur 3 rd BHTC workshop

EEE4106Z Radiation Interactions & Detection

Radioactivity and Ionizing Radiation

Development of beam delivery systems for proton (ion) therapy

Geometry Survey of the Time-of-Flight Neutron-Elastic Scattering (Antonella) Experiment

Information about the T9 beam line and experimental facilities

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

Radiation Dose, Biology & Risk

Overview and Status of the Austrian Particle Therapy Facility MedAustron. Peter Urschütz

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Calibration and applications of modern track detectors CR-39/PM-355 in nuclear physics and high temperature plasma experiments

General Physics (PHY 2140)

General Physics (PHY 2140)

Spawning Neutrons, Protons, Electrons and Photons from Universities to Society

LNL IRRADIATION FACILITIES

Radionuclide Imaging MII Detection of Nuclear Emission

Available online at ScienceDirect. Energy Procedia 71 (2015 ) Yokohama, Kanagawa, Japan

CRaTER Pre-Environmental Review (I-PER) Science Requirements Update

GLOSSARY OF BASIC RADIATION PROTECTION TERMINOLOGY

WHAT HAPPENS to a mammalian cell, or a neighboring

Energy response for high-energy neutrons of multi-functional electronic personal dosemeter

Core Questions Physics unit 4 - Atomic Structure

Measuring magnetic field fluctuations for use in decreasing microbeam spot size

ICTP-IAEA Joint Workshop on Nuclear Data for Science and Technology: Medical Applications. 30 September - 4 October, 2013

Nuclear Physics and Astrophysics

Particle Energy Loss in Matter

1.5. The Tools of the Trade!

L-35 Modern Physics-3 Nuclear Physics 29:006 FINAL EXAM. Structure of the nucleus. The atom and the nucleus. Nuclear Terminology

Beam Diagnostics and Instrumentation JUAS, Archamps Peter Forck Gesellschaft für Schwerionenforschnung (GSI)

Imaging Methods: Scanning Force Microscopy (SFM / AFM)

WHAT IS IONIZING RADIATION

Calibration of the IXPE Instrument

Proposed laser ion source for the Columbia University microbeam

Markus Roth TU Darmstadt

Refurbishment of the Electrostatic Accelerators of ithemba LABS

Recent Activities on Neutron Calibration Fields at FRS of JAERI

Modern physics ideas are strange! L 36 Modern Physics [2] The Photon Concept. How are x-rays produced? The uncertainty principle

Light ion recoil detector

1.4 The Tools of the Trade!

MONTE-CARLO SIMULATIONS OF TIME- RESOLVED, OPTICAL READOUT DETECTOR for PULSED, FAST-NEUTRON TRANSMISSION SPECTROSCOPY (PFNTS)

Section 3: Nuclear Radiation Today

INFLUENCE OF EXPOSURE GEOMETRY ON THE RESPONSE OF CR39 SSNT RADON DETECTORS *

SLAC National Accelerator Laboratory FACET & TEST BEAM FACILITIES PROPOSAL

Particle Energy Loss in Matter

High Resolution Optical Spectroscopy

PHITS calculation of the radiation field in HIMAC BIO

ICALEPCS Oct. 6-11, 2013

ABSOLUTE AIR-KERMA MEASUREMENT IN A SYNCHROTRON LIGHT BEAM BY IONIZATION FREE-AIR CHAMBER

A diamond detector for Space Research and Therapy. Radek Pleskac (GSI Darmstadt)

Cytogenetic signature of heavy charged particles: impact of LET and track structure

Track Etch Detectors (TED)

INAYA MEDICAL COLLEGE (IMC) RAD LECTURE 1 RADIATION PHYSICS DR. MOHAMMED MOSTAFA EMAM

DIANA A NEXT GENERATION DEEP UNDERGROUND ACCELERATOR FACILITY

SECTION 8 Part I Typical Questions

Solution to the ion feedback problem in Hybrid Photon Detectors and Photo Multiplier Tubes a

Towards efficient and accurate particle transport simulation in medical applications

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Estec final presentation days 2018

SCINTILLATION DETECTORS AND PM TUBES

Radioactivity INTRODUCTION. Natural Radiation in the Background. Radioactive Decay

Radiation Safety. PIXE PAN 2008 Ed Stech University of Notre Dame

P7 Radioactivity. Student Book answers. P7.1 Atoms and radiation. Question Answer Marks Guidance

08 - Miscellaneous and historical detectors

custom reticle solutions

Multilayer Nuclear Track Detectors for Retrospective Radon Dosimetry

Revision Guide for Chapter 18

X-Rays From Laser Plasmas

Lecture 4 Scanning Probe Microscopy (SPM)

Queen s University PHYS 352

Track measurements of fast particle streams. from the pulse-discharge explosion-induced plasma. Ukraine

INAYA MEDICAL COLLEGE (IMC) RAD LECTURE 1 RADIATION PHYSICS DR. MOHAMMED MOSTAFA EMAM

APPLIED RADIATION PHYSICS

Introduction to Accelerator Physics Part 1

X-ray Interaction with Matter

Research Physicist Field of Nuclear physics and Detector physics. Developing detector for radiation fields around particle accelerators using:

Introduction to Accelerator Physics Part 1

College Physics B - PHY2054C

INTRODUCTION TO IONIZING RADIATION (Attix Chapter 1 p. 1-5)

CHAPTER 12 TEST REVIEW

= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

General concept and defining characteristics of AFM. Dina Kudasheva Advisor: Prof. Mary K. Cowman

A Multi-beamlet Injector for Heavy Ion Fusion: Experiments and Modeling

2. Which of the following statements help(s) to explain why gas can fill the vessel containing it completely while liquid cannot?

Radioactivity. Lecture 6 Detectors and Instrumentation

The KATRIN experiment

Basic physics Questions

Chapter 29. Nuclear Physics

Radiation Detection and Measurement

Transcription:

310/1828 310/4 Workshop on Biomedical Applications of High Energy Ion Beams Co-sponsored by: ICGEB and University of Surrey 12-16 February 2007 Venue: Adriatico Guest House Giambiagi Lecture Hall ICTP, Trieste, Italy Microbeam Technology Melvyn FOLKARD Gray Cancer Institute, U.K.

Microbeam technology (in radiation biology) Melvyn Folkard, Kevin Prise, Borivoj Vojnovic University of Oxford, Gray Cancer Institute, PO Box 100, Mount Vernon Hospital, Northwood, HA6 2JR UK folkard@gci.ac.uk

Microbeams in radiobiology Typically, cellular radiobiological effect is measured by irradiating and analysing cell populations. dose 1 dose 2 dose 3 dose 4 However, using a microbeam, it is now possible to irradiate individual cells within cell populations or tissues, or indeed selected parts of a cell. This is very useful! microbeam

What is a microbeam? For radiation biology applications, a microbeam is a facility for aiming a micron-sized beam of ionizing radiation at a biological target (for example, the nucleus of a cultured mammalian cell). Most microbeams use collimated or focussed energetic ions Microbeams have also be developed that use focussed low-energy X-rays and electrons Microbeams require methods for identifying and aligning the target to the radiation beam Precise dose delivery requires that the amount of delivered radiation to each target is controlled If many cells are to be irradiated, then the process of identifying, aligning and irradiating cells should be automated

What is a microbeam? The radiations used in microbeam experiments have poor penetration in tissue (~few tens of microns), so specially designed cell dishes are needed cell culture media cells dish wall thin plastic membrane dish base Only cell types that attach to the plastic membrane can be used

What is a microbeam? CCD camera cell finding microscope cell positioning computer control stage detector micrometer- sized radiation beam shutter

Rationale for microbeams Advantages of microbeam methods: Can selectively irradiate individual cells within a cell population Can selectively irradiate individual parts of individual cells Can irradiate single cells with exact low doses (i.e. single ion) Single cell assay implicit in method Advantages of non-microbeam (broad-field) methods: Most irradiation equipment available commercially Well-established methods for irradiating biological samples Procedures often straightforward to implement and execute Can be used for experiments in vitro or in vivo Large sample volumes irradiated quickly

Rationale for microbeams Irradiate individual cell (or cells) within a cell population The method of choice for investigating the bystander effect Cell-to-cell communication, either through gap-junctions, or soluble factors are important, and can be studied through microbeam experiments gap junction soluble factors

Rationale for microbeams Selectively irradiate individual parts of individual cells 10 m 10 m nucleus targeted cytoplasm targeted Conventional wisdom is that irradiating just the cytoplasm (no genomic DNA) is ineffective at low-to-moderate doses Microbeam experiments challenge conventional wisdom!

Rationale for microbeams Irradiate single cells with a single particle: microbeam microbeam No. cells exposed 0 1 2 3 4 5 No. particle traversals though cell Microbeam: exactly of one particle per cell 100% traversed by exactly one particle

Radiation risk weapons fallout nuclear power thoron Radon daughters are inhaled and irradiate lung cells food cosmic radon medical -rays radon? Radon daughters are -particle emitters. In the south-west of England, estimates are that 1 in 20 lung cancers are due to radon Average UK dose is 2.5 millisieverts per year

Radiation risk weapons fallout food nuclear power thoron A typical background dose 2.5 msv per year is equivalent to: cosmic medical radon? radon ~1 electron track / cell / year ~1 -particle track / cell / century -rays However, one -particle deposits ~several hundred-fold greater dose (per cell) than one electron The probability of a cell being crossed by more than one -particle is remote. Therefore, radon risk arises from a single -particle traversal of a cell

Microbeam specifications Accuracy: Need to reliably target the cell nucleus, or cytoplasm i.e. ~1-2 m targeting accuracy Detection: Single particle delivery requires efficient real-time detection and shuttering Imaging and alignment: Ability to image target, log position and to precisely align target to microbeam. Ability to revisit cells Speed: Up 5,000 cells per dish; rapid, automated cell finding and irradiation essential Environment: Cell-friendly environment; cells in media, preferably vertical beamline

Development of microbeams Worldwide The first application of a charged-particle microbeam in radiobiology was a collimated system in 1953 (Zirkle and Bloom, 1953 Science 117, 487) The first modern microbeam was developed by Braby (Pacific North West, USA) in the late 1980s. This used vertically collimated light ions but was dismantled in the mid-1990s (Braby, 1992, Scanning Microscopy, 6, 167) The second microbeam was developed at RARAF, New York in the early 1990s. This also uses vertically collimated light ions (Geard et. al, 1991, Nucl. Instr. Meth., B54, 411) The third microbeam was developed by us at Gray Cancer Institute in the mid 1990s. Like the RARAF and PNL facilities. It also uses vertically collimated light ions. (Folkard et. al, 1997, Int. J. Radiat. Biol., 72, 375)

Development of microbeams Worldwide 30 25 Microbeams being designed or developed Routinely irradiating cells 20 q y 15 10 5 1988 90 92 94 96 98 00 02 year 04 06

Radiation Type (ions) Particle sources for particle microbeams Typically, microbeams make use of particle accelerators It is possible to use an -particle isotope source instead Most radiobiological microbeams use light ions protons p helium ions 3 He 2+, 4 He 2+ Some microbeams use heavy ions i.e. SNAKE Munich heavy ion microbeam: GSI Darmstadt heavy ion microbeam: JAERI Takasaki heavy ion microbeam: protons gold ions carbon ions uranium ions argon ions, neon ions

Comparison of advanced ion facilities mature emerging RARAF New York H Fe 5 MV singletron (>2006) He 4.2 MV VdG (<2006) GCI, Northwood H, He ions 4 MV VdG JAERI Takasaki heavy ions 90 MV AVF Cyclotron SNAKE Munich heavy ions 14 MV tandem GSI Darmstadt heavy ions linear accelerator 11.4 MeV/u PTB Braunschweig H, He ions 20 MV cyclotron INFN-LNL Legnaro H, He ions 7 MV VdG LIPSION Leipzig H, He ions 3.5 MV singletron CENBG Bordeaux H, He ions 3.5 MV singletron NIRS Chiba H, He ions 3.4 MV HVEE tandem IFJ Krakow H, He ions 2.5 MeV VdG

Ion sources for particle microbeams Protons Most penetrating for given accelerator Useful LET range (10 40 kev m -1 ) Relevant to proton radiotherapy Easily scattered Helium ions Radiobiolically relevant to risk (radon) Good penetration, less readily scattered Heavy ions (Very) high LET studies Particle radiotherapy, other than protons Reduced scattering Limited radiobiolical relevance

Microbeam orientation The preferred orientation for a radiobiological microbeam is vertically up Cell dish design more complex in other directions transparent cap to contain culture media needed horizontal microbeam gravity can cause plastic window to bow unpredictably

Microbeam orientation Nevertheless, several microbeams use a horizontal orientation Horizontally oriented systems usually developed around an existing horizontal beamline, or microbeam thin gap containing cells humidified gas GSI Darmstadt

Comparison of advanced ion facilities mature emerging RARAF New York He ions vertically up GCI, Northwood H, He ions vertically up JAERI Takasaki heavy ions vertically down SNAKE Munich heavy ions horizontal GSI Darmstadt heavy ions horizontal PTB Braunschweig H, He ions vertically down INFN-LNL Legnaro H, He ions horizontal LIPSION Leipzig H, He ions horizontal CENBG Bordeaux H, He ions horizontal NIRS Chiba H, He ions vertically up IFJ Krakow H, He ions horizontal

Methods of producing a microbeam A microbeam of ions can be formed by collimation or focussing Advantages and disadvantages of collimation: Low-cost technology Can be compact Scattering limits spot size to a few microns Advantages and disadvantages of focussing: Sub-micron spot sizes possible Steerable beam Greater space requirement Greater cost and complexity Power supplies required Existing microprobes available (but horizontal)

Methods of producing a microbeam: collimation The RARAF collimator uses two laser-drilled apertures separated by 300 m and mounted on a gimbal 92% of particles within 3 m radius Randers-Pehrson et. al. 2001, Radiat. Res., 156, 210

Methods of producing a microbeam: collimation 1 mm X 0.25 mm glass capillary, 1 m bore The GCI collimator uses a single glass capillary, mounted on a gimbal gimbal, formed by opposing screws 98% of particles within 2 m radius

Methods of producing a microbeam: focussing Focussing can be either magnetic or electrostatic Low energy beams can use magnetic solenoids At MeV energies, quadrupole lenses are used N S S N Oxford Microbeams Ltd Triplet Lens system

Methods of producing a microbeam: focussing Focussing can be either magnetic or electrostatic Low energy beams can use magnetic solenoids At MeV energies, quadrupole lenses are used doublet Oxford triplet Russian quadruplet

Methods of producing a microbeam: focussing Electrostatic focussing Advantages of electrostatic focussing: No hysteresis inherent in magnetic lenses, allowing easy change between differing LET beams. Stable voltage is more readily achieved than stable current The focal properties of electrostatic lenses depend only on the accelerating potential.

Comparison of advanced ion facilities mature emerging RARAF New York He ions collimation / focussing GCI, Northwood H, He ions collimation JAERI Takasaki heavy ions collimation SNAKE Munich heavy ions focusing GSI Darmstadt heavy ions focusing PTB Braunschweig H, He ions focusing INFN-LNL Legnaro H, He ions collimation LIPSION Leipzig H, He ions focusing CENBG Bordeaux H, He ions focusing NIRS Chiba H, He ions focusing IFJ Krakow H, He ions focusing

Particle detection An important requirement of an ion microbeam is that the number of particles incident on the target can be controlled Therefore an efficient particle detection and shuttering system is needed Shuttering is usually by fast electrostatic deflection of the beam Possible methods of detections include: Scintillation foils Gas proportional counters Solid-state diode detectors Channeltron detectors Track-etch plastic

Particle detection The detection problem A detector placed before the sample has to be very thin. detector Even a thin detector will scatter the particles (reducing accuracy) humidified gas detector detector To use a detector after the sample, the liquid is removed and the cells are bathed in humidified gas

Particle detection Examples: Gray Cancer Institute Photomultiplier tube 18 m scintillation foil Problem: Photomultiplier tube replaces microscope objective, therefore cannot view cells during irradiation

Particle detection Examples: GSI, Darmstadt 200 nm Si 3 N 4 window + 2 nm Au + 100 nm CsI cells e - channeltron Problem: Not 100% efficient for light ions

Particle detection Examples: Takasaki heavy ion microbeam thin Kapton film collimator CR-39 KOH etching process cells CR-39 track-etch plastic pits in CR-39 Problem: Retrospective detection; cannot be used to control the number of particle traversals image of cell

GCI charged-particle microbeam Case study: The Gray Cancer Institute light ion microbeam

GCI charged-particle microbeam The Gray Cancer Institute microbeam uses a 4 MV Van de Graaff accelerator It is used to accelerate protons and helium ions A dedicated vertical beamline has been added for use as a microbeam

GCI charged-particle microbeam Microbeam room 4MV Van de Graaff

GCI charged-particle microbeam CCD intensified camera epi-fluorescent illumination water-immersion objective 3-axis motorised sample stage collimator assembly stage support and Z drive optical table

Cell finding step Stained cells are viewed using an epi-fluorescence microscope microscope cell dish microbeam collimator collimator

Cell finding step A map of cell co-ordinates is found by raster-scanning the dish and using image-processing to ascertain cell positions cell dish cell dish 5 mm 10 mm

Cell finding step microscope field of view cell nucleus cell map Typical screenshot during cell-finding step

Irradiation step Collimator exit window assembly 5 m photons 3 m Mylar scintillator (Bicro BC400) vacuum window (3 m Mylar) collimator

Irradiation step photo-multiplier tube assembly collimator Collimator assembly touches base of cell dish

Irradiation step: Beam shuttering PM TUBE PULSE-HEIGHT AMPLIFIER / DISRIMINATOR preset counter PC control MECHANICAL SHUTTER ELECTROSTATIC DEFLECTOR

Irradiation step: detector performance Failure to correctly count particles can occur in two ways: Failure to detect particle traversal False positives noise pulses due to particles counts discriminator threshold pulse height Photomultiplier tube pulse-height spectrum for many particles

Irradiation step: detector performance Detector performance can be assessed using CR-39 track-etch plastic 25 mm Polyallyl diglycol carbonate (PADC), CR-39 is a clear plastic, sensitive to the tracks of energetic particles After exposure, the tracks may be revealed by etching the material in a caustic alkali solution (i.e. NaOH). 20 m

Irradiation step: detector performance 20 m Preset No. particles 1 2 3 4 5 0 0.8 - - - - No. particles Delivered 1 2 3 4 5 6 99.2 - - - - - 0.9 99.1 - - - - - 2.5 97.5 - - - - - 2.2 97.2 0.6 - - - 0.3 3.1 96.3 0.3 7 - - - - - Exactly 3 pits per location, on a 20 m grid

Irradiation step: detector performance Biological visualisation of detector performance Three counted helium ions per cell 5 m

Irradiation step: cell throughput 1 Position cell 2 Raise collimator 3 Irradiate 4 Lower collimator

Irradiation step: cell throughput 1. Position cell 3. Irradiate 2. Raise collimator 4. Lower collimator 1 2 3 4 0 100 200 300 400 milliseconds 500 read, write, handshaking irradiate stage instructions stage movement collimator instructions collimator movement Throughput: 450 milliseconds / cell (8,000 cells / hour)

Irradiation step: targeting accuracy What is the particle microbeam targeting accuracy? Targeting accuracy is determined by: Accuracy of beam identification and location Accuracy of target identification and location Target positioning accuracy Beam size

Beam identification & location CCD camera can be used to visualise the beam 20 m For every dish, the beam location is established after the cell-finding step and before the irradiation step ~1 m uncertainty in beam location

Target identification & location Target identification accuracy is determined by: Ability to visualize target Optical distortions in image Countermeasures: Optical distortions in image: Measure distortion and apply a correction using a look-up table OR move cell to irradiation position and find again

Target positioning accuracy Target positioning accuracy is determined by: Mechanical stability Stage accuracy Countermeasures: Mechanical stability: vibration isolation, robust construction, temperature stability Stage accuracy: Stage is lead-screw driven, ensure anti-backlash measures are used. Use a stage with position sensors to provide closed-loop position feedback

Beam size Beam size is determined by: Collimator bore diameter Scattering in collimator, window and detector Collimator to cell distance 20 m 2.5 MeV proton (SRIM2003)

Beam size Beam size is determined by: Collimator bore diameter Scattering in collimator, window and detector Collimator to cell distance 20 m Thicker scintillator 2.5 MeV proton (SRIM2003)

Beam size Beam size is determined by: Collimator bore diameter Scattering in collimator, window and detector Collimator to cell distance 20 m Increased collimator to cell distance air gap 2.5 MeV proton (SRIM2003)

Measuring radiation damage to cells -H2AX assay: indicates the presence of DNA double strand breaks Single helium ion 5 m

Measuring radiation damage to cells Micronucleus assay micronuclei After irradiating cells, score bi-nucleate cells with micronuclei

Measuring radiation damage to cells Single cell clonogenic survival assay Target individual cells Revisit and score colonies

Measuring radiation damage to cells 6 5 4 y / mm 3 2 1 1 2 3 4 5 6 x / mm

Measuring radiation damage to cells 6 5 4 y / mm 3 2 1 1 2 3 4 5 6 x / mm

The future The University of Surrey / ROB vertical scanning nanoprobe

The competition The focused electron microprobe Energetic electrons are relatively easy to generate and focus Range in water / m 100 10 1.0 0.1 0.01 1 10 100 Electron energy / kev For 5 m thick cell, need ~25 kv electrons Problem: secondary electrons ranges ~cell diameter

The competition The focused low-energy X-ray microprobe The Gray Cancer Institute low energy X-ray microprobe

Focussing low-energy X-rays 0.4 mm Low-energy X-rays can be focussed using diffraction lenses called zone-plates Manufacture is highly specialised- limited to a few laboratories (i.e. King s College, London) 1 st order diffracted X-rays aperture zone plate 20 m

X-rays and charged-particles compared X-rays Properties similar to hard X-rays and -rays Interact by photoelectric effect; no scattering Capable of very fine probes; less than 50nm Can deliver very low doses per cell Low-cost bench-top sources possible Charged-particles High LET single-particle source Instantaneous dose-rate High cell throughputs Greater penetration in tissue possible Collimation straightforward