TLC. Thin Layer Chromatography. State-of-the-art TLC products. Quality Efficiency Selectivity.

Similar documents
Sample Preparation TLC Plates

CHROMATOGRAPHY. NUCLEOSIL the original HPLC. Find what you are looking for!

Columns and supplies catalog

Thin Layer Chromatography

TLC Introduction. tlc Choose Stationary Phase. Select Visualization Technique. Choose a Mobile Phase

Thin layer chromatography

Contents...4. Solid phase extraction...8. Sample filtration Vials and caps Liquid chromatography Thin layer chromatography...

Determination of organic acids in fruit juices and white wines

Thin Layer Chromatography

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Adsorbents for TLC. Adsorbents for TLC

Packings for HPLC. Packings for HPLC

Water Analysis VISOCOLOR VISOCOLOR. Water analysis made easy. VISOCOLOR tests for water analysis

Laboratory Exercise: Chromatographic Separation

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

HPLC Sample Preparation

Chromatographic Methods of Analysis Section 2: Planar Chromatography. Prof. Tarek A. Fayed

637. Thiamethoxam. HPLC method

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

The Plus for your lab!

Thin Layer Chromatography

Physical Separations and Chromatography

Manual Accompanying The GPHF-Minilab

Experiment 1: Thin Layer Chromatography

Chromatography: Thin-Layer Chromatography (TLC) & Column Chromatography

Shodex TM ODP2 HP series columns

GPC-/SEC-Columns. MZ-Gel SD. MZ-Gel Super FG SEC with fluorinated Eluents

ETD Verification Kit

TLC Introduction. prep flash tlc. tlc. Thin Layer Chromatography to Preparative Chromatography. Steps for Method Development

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

For Chromatography, you might want to remember Polar Dissolves More, not like dissolves like.

HPLC Column Material - Bulk Ware

Dynasylan SIVO 110. Description. Product Information. SIVO SOL Technology for coating systems

Lonicera japonica Flower Dry Extract. Proposed For Development Version 0.1. Published on Herbal Medicines Compendium (

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - CHROMABOND. Catalogue 9. Hichrom Limited

Bulk Silica Gels. SiliaFlash Irregular Silica Gels SiliaSphere PC Spherical Silica Gels

á1064ñ IDENTIFICATION OF ARTICLES OF BOTANICAL ORIGIN BY HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY PROCEDURE

Experiment Nine Thin Layer Chromatography

LC and LC/MS Column Selection Flow Chart

Is There a Chemist in You?

Principles of Thin Layer Chromatography

Chapter content. Reference

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Chromatography. writing in color

Chromatography 1 of 26 Boardworks Ltd 2016

IDENTIFICATION AND DETERMINATION OF HYDROQUINONE IN COSMETIC PRODUCTS 2 14/11/17 ACM 003 BY TLC AND HPLC

ETD Verification Kit II

EXPERIMENT #1 SEPARATION AND RECOVERY OF ORGANIC COMPOUNDS, THIN LAYER CHROMATOGRAPHY, COLUMN CHROMATOGRAPHY, CRYSTALLIZATION AND MELTING POINTS

PRINCIPLES AND APPLICATION OF CHROMATOGRAPHY. Dr. P. Jayachandra Reddy Mpharm PhD Principal & professor KTPC

TLC Introduction. prep flash tlc. tlc. Thin Layer Chromatography to Preparative Chromatography. Steps for Method Development

Exercise 4: Thin layer chromatography of organic compounds

State-of-the-art C18 HPLC Columns

BGB Flash Cartridges. Ultra-pure silica-based material. High-performance spherical 30 µm C18, CN, Diol & HILIC. Pressure up to 27 bar (400 psi)

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

VOC TEST REPORT CDPH

Liquid Chromatography

CHEMICAL SEPARATION EXPERIMENT 2

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Name Period Date. Lab 10: Paper Chromatography

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

PAPER AND THIN LAYER CHROMATOGRAPHY (TLC)

ImpSilHPLC Columns. The solution for your chromatography IMPTECH SCIENTIFIC

GL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI

Chromatography Extraction and purification of Chlorophyll CHM 220

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

HIPPURIC ACID and o-m-p- METHYLHIPPURIC ACIDS IN URINE BY UV CODE Z06010

Scott Anderson, Kathy Lawrence Dennis McCreary, Melissa Wilcox. Grace Davison Discovery Sciences

Prelab Reading Assignment: Laboratory Techniques in Organic Chemistry, 4 th Ed. Chapter 19

Chromatography & instrumentation in Organic Chemistry

AppNote 5/2008. Automation of Sample Preparation Steps using a Robotic X-Y-Z Coordinate Autosampler with Software Control KEYWORDS ABSTRACT

Hypersil BDS Columns TG 01-05

This method describes the identification of the following prohibited colorants in cosmetic products:

University of Wisconsin Chemistry 524 Introduction to Separations Methods *

Immunoassay Kit (Colorimetric)

CREATING TOMORROW S SOLUTIONS HEAT-SEALABLE COATINGS I PRINTING INKS I INDUSTRIAL COATINGS VINNOL SURFACE COATING RESINS PRODUCT OVERVIEW

Lab.2. Thin layer chromatography

What actually are dietary supplements? They are consumed in large quantities, but they

InertSustainSwift C8

Mass Spectral Studies of Polypropylene Chromatographic Well Plates

Flk = Acy + Cy z. Discover the perfect formula Fluka Reagents. Fluka TM Accuracy Consistency AUTHENTIC

High Pressure/Performance Liquid Chromatography (HPLC)

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

Particle Analysis at the Touch of a Button. Litesizer series

The solution for all of your

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

CHIRAL SEPARATION USING THIN LAYER CHROMATOGRAPHY

YMC-Triart Prep. Robust Improved particle properties result in better chromatographic performance

H 3 CO H 3 CO S CH 3

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

high performance OPTIC 3 and applications a total analytical solution

Metolachlor ESA Sodium Salt Standard

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

High Performance Liquid Chromatography

High Performance Liquid Chromatography

MEMBREX. Ready-to-use Syringe Filters < 1 up to 100 ml. Minimizes Loss of Sample. Minimale Holdup-Volume. Low Adsorption.

Optimized Flash Chromatography Purification: From TLC to large scale in three steps

Advantages of polymerbased. an alternative for ODS

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

Transcription:

TLC Thin Layer Chromatography State-of-the-art TLC products Quality Efficiency Selectivity www.mn-net.com

MACHEREY-NAGEL Thin Layer Chromatography for more than 5 decades Why TLC? Fast and cost-saving separation technique Multiple sample application possible Developed plate serves as analytical documentation media Time consuming sample preparation steps can be obmitted MN ready-to-use layers for TLC and HPTLC Comprehensive range of plate sizes, surface chemistries and backings Pre-coated plates ready for immediate use Homogeneous, smooth and well adhering layers Available with UV indicator or non-impregnated Consistent high quality from batch-to-batch and from plate-to-plate

Benefits of TLC TLC does not require complex, costly maintained instrumentation. The investment for performing successful TLC can be hundred times less than for HPLC. Since the separated compounds remain on the plate, they can be used for further experiments. Method development is simplified by TLC. The amount of solvents required for development is much less than with HPLC. Standard analytical TLC plates and sheets Thin layer chromatography can be used for both qualitative and quantitative analysis. Standard analytical TLC plates typically have adsorbent layers that are nominally between 0.20 0.25 mm in thickness. Preparative TLC plates Preparative TLC is used for purification and isolation of analytes from impurities. Preparative TLC layers ( 0.5 mm) are only on glass plates available.

In order to meet your individual application requirements three different types of backings are available. TLC plates - glass backing Glass plates are robust, heat proof and chemically resistant to all common mobile phases and visualization reagents. POLYGRAM TLC sheets - Polyester (PET) backing Polyester sheets are easy to handle, lightweight and flexible. Developed POLYGRAM sheets can also be stored for documentation in laboratory notebooks. Scissors cutting possible. ALUGRAM TLC sheets - aluminium backing Aluminium sheets are easy to handle, lightweight and flexible. High performance silica on ALUGRAM Xtra sheets provides outstanding wettability for precise colorization results, even with 100 % aqueous detection reagents. Moreover ALUGRAM Xtra sheets are easy to cut with scissors. No flaking of silica occurs!

Physical properties of backing materials Material glass polyester aluminium Thickness (approx.) 1.3 mm 0.2 mm 0.15 mm Weight, packing and storage requirement high low low Torsional strength ideal low relatively high Temperature stability high max. 185 C high Susceptible to breakage yes no no Can be cut with scissors no yes yes Chemical resistance of support material against solvents high high high against mineral acids and conc. ammonia high high low Stability of the binder system of NP plates in water Suitability for aqueous detection reagents depends on phase very suitable ALUGRAM : limited suitability ALUGRAM Xtra: well suited

Standard silica TLC ready-to-use glass plates MN offers SIL G and ADAMANT as silica coated glass plates. Analytical TLC glass plates: Silica 60, specific surface (BET) ~ 500 m 2 /g, mean pore size 60 Å, specific pore volume 0.75 ml/g, particle size 5 17 μm, thickness of layer 0.25 mm 2 different selectivities for the separation of nitroanilines, separations under identical conditions Brilliant UV indicator on ADAMANT plates 1 2 3 } R f 0.20 } R f 0.05 1 2 3 } R f 0.12 } R f 0.08 Sil G ADAMANT ADAMANT Competitor M ADAMANT without separation Plate size [cm] Plates per pack SIL G* smooth surface easy to scrape off low polarity binder with UV 254 nm with UV 254/366 nm without UV indicator ADAMANT hard surface can be pen labeled brilliant UV indicator system with UV 254 nm without UV indicator 2.5 x 7.5 100 809028.100 5 x 10 200 809027.200 821010.200 50 809027 809017 821010 821040 5 x 20 100 809021 809121 809011 821015 10 x 10 25 809020 809010 821020 821050 10 x 20 50 809022 809122 809012 821025 821070 20 x 20 25 809023 809123 809013 821030 821060 *Also available as preparative plates in 0.50, 1.00 and 2.00 mm thickness.

POLYGRAM SIL G and SIL N-HR Polyester sheets for TLC Silica 60, specific surface (BET) ~ 500 m 2 /g, mean pore size 60 Å, specific pore volume 0.75 ml/g, particle size 5 17 μm; standard grade The binder system for POLYGRAM sheets is also completely stable in purely aqueous eluents. POLYGRAM SIL G Designation Thickness Plate size Fluorescent Plates of layer [cm] indicator per pack SIL G 0.20 mm 2.5 x 7.5 200 805902 SIL G 0.20 mm 4 x 8 50 805032 SIL G 0.20 mm 5 x 20 50 805012 SIL G 0.20 mm 20 x 20 25 805013 SIL G 0.20 mm 40 x 20 25 805014 SIL G UV 254 0.20 mm 2.5 x 7.5 UV 254 200 805901 SIL G UV 254 0.20 mm 4 x 8 UV 254 50 805021 SIL G UV 254 0.20 mm 5 x 20 UV 254 50 805022 SIL G UV 254 0.20 mm 20 x 20 UV 254 25 805023 SIL G UV 254 0.20 mm 40 x 20 UV 254 25 805024 SIL G UV 254 0.20 mm 500 x 20 UV 254 1 roll 805017 POLYGRAM SIL N-HR Different binder system compared to SIL G results in different separation characteristics Special feature of POLYGRAM SIL N-HR: higher gypsum content SIL N-HR UV 254 0.20 mm 5 x 20 UV 254 50 804022 SIL N-HR UV 254 0.20 mm 20 x 20 UV 254 25 804023

ALUGRAM Xtra SIL G Standard silica layers on aluminium for TLC Silica 60, specific surface (BET) ~ 500 m 2 /g, mean pore size 60 Å, specific pore volume 0.75 ml/g, particle size 5 17 μm; standard grade Outstanding wettability for precise colorization results, even with 100 % aqueous detection reagents Excellent separation efficiency and reproducibility from lot to lot Easy and reliable cutting due to an optimized binder system, no flaking of silica Binder: highly polymeric product, which is stable in almost all organic solvents and resistant towards aggressive visualization reagents; also completely stable in purely aqueous eluents For applications, visit www.mn-net.com/apps Tailored to individual requirements ALUGRAM Xtra SIL G aluminium sheets Designation Thickness of layer Plate size [cm] Fluorescent indicator Plates per pack SIL G 0.20 mm 20 x 20 25 818233 SIL G UV 254 0.20 mm 4 x 8 UV 254 50 818331 SIL G UV 254 0.20 mm 20 x 20 UV 254 25 818333

Nano TLC plates Higher efficiency on smaller particles... Sharper separations Shorter developing times and migration distances Smaller sample volumes 0.01 0.1 μl Minimal diffusion Increased detection sensitivity Analytical HPTLC glass plates: Silica 60, specific surface (BET) ~ 500 m 2 /g, mean pore size 60 Å, specific pore volume 0.75 ml/g, thickness of layer 0.20 mm, mean particle size range 2 10 μm Comparison of ADAMANT and Nano-ADAMANT plates Separation of anthraquinone dyes Layers: A: ADAMANT, B: Nano-ADAMANT Sample: 1μL about 0.1 % Eluent: toluene-cyclohexane (4:3, v/v) Migration time: A) 30 min, B) 15 min Peaks: 1. Blue 3 A: ADAMANT 2. Violet 2 3. Red 1 4. Green 5. Blue 1 6. Greenish Blue 2 7. Violet 1 3 4 5 6 7 10 20 30 40 50 mm B: Nano-ADAMANT 1 2 3 4 5 6 7 10 20 30 40 mm Plate size [cm] Glass plates Plates per pack with UV 254 nm Nano-SIL without UV indicator with UV 254 nm Nano-Adamant without UV indicator 5 x 5 100 811021 811011 821100 821130 10 x 10 25 811022 811012 821110 821140 10 x 20 50 811023 811013 821120 821150 ALUGRAM Xtra 5 x 20 50 818342 818240 20 x 20 25 818343 818241

Preadsorbent zone After sample application in the kieselguhr layer the spots migrate to the kieselguhr/silica interface forming narrow bands. Separation then takes place in the silica layer. Concentrating zone - SILGUR Concentrates sample spots on the plate Simplifies sample preparation and application Channeled SILGUR plates Channel-Plates with 19 channels help to prevent cross contamination by separating several samples. More samples can be separated on a plate, and spot areas can be more easily determined.

Designation Thickness of layer Plate size [cm] Fluorescent indicator Plates per pack Glass plates SILGUR-25 0.25 mm 10 x 20 50 810012 SILGUR-25 0.25 mm 20 x 20 25 810013 SILGUR-25 UV 254 0.25 mm 10 x 20 UV 254 50 810022 SILGUR-25 UV 254 0.25 mm 20 x 20 UV 254 25 810023 Glass plates Channel Plates SILGUR-25-C UV 254 0.25 mm 20 x 20 UV 254 25 810123 ALUGRAM Xtra aluminium sheets SILGUR 0.20 mm 10 x 20 20 818412 SILGUR 0.20 mm 20 x 20 25 818413 SILGUR UV 254 0.20 mm 10 x 20 UV 254 20 818422 SILGUR UV 254 0.20 mm 20 x 20 UV 254 25 818423 Glass plates Nano-SILGUR-20 0.20 mm 10 x 10 25 811032 Nano-SILGUR-20 UV 254 0.20 mm 10 x 10 UV 254 25 811042 ALUGRAM Xtra aluminium sheets Nano-SILGUR 0.20 mm 10 x 10 25 818432 Nano-SILGUR UV 254 0.20 mm 10 x 10 UV 254 25 818442

MACHEREY-NAGEL TLC accessory Description Simultaneous developing chamber for TLC 20 x 20 cm, for up to 5 plates 814019 10 x 10 cm, for up to 2 plates 814018 MN Alugram scissors 818666 818666 814019 814018 HPLC GC SPE and Flash Syringe filters Vials and caps www.mn-net.com... we Meet your Needs KATEN200146_TLC-Flyer20/20_EN1/2/5/7.14/PD Printed in Germany EN ISO 9001: 2008 CERTIFIED MACHEREY-NAGEL GmbH & Co. KG Neumann-Neander-Str. 6 8 52355 Düren Germany Germany and international: Switzerland: MACHEREY-NAGEL AG France: MACHEREY-NAGEL EURL Tel.: +49 24 21 969-0 Tel.: +41 62 388 55 00 Tel.: +33 388 68 22 68 Fax: +49 24 21 969-199 Fax: +41 62 388 55 05 Fax: +33 388 51 76 88 E-mail: info@mn-net.com E-mail: sales-ch@mn-net.com E-mail: sales-fr@mn-net.com USA: MACHEREY-NAGEL Inc. Tel.: +1 484 821 0984 Fax: +1 484 821 1272 E-mail: sales-us@mn-net.com