Indoor Climate of Large Glazed Spaces Hendriksen, Ole Juhl; Madsen, Christina E.; Heiselberg, Per Kvols; Svidt, Kjeld

Similar documents
Aalborg Universitet. Natural Ventilation in Atria Svidt, Kjeld; Heiselberg, Per Kvols; Hendriksen, Ole Juhl. Publication date: 1996

Characterization of the Airflow from a Bottom Hung Window under Natural Ventilation

Aalborg Universitet. Windows Heiselberg, Per Kvols; Svidt, Kjeld; Nielsen, Peter Vilhelm. Publication date: 2000

Aalborg Universitet. Comparison between Different Air Distribution Systems Nielsen, Peter Vilhelm. Publication date: 2006

Aalborg Universitet. Computer Prediction of Air Quality in Livestock Buildings Svidt, Kjeld; Bjerg, Bjarne. Publication date: 1996

Aalborg Universitet. Published in: Proceedings of Roomvent Publication date: 2007

Aalborg Universitet. Publication date: Document Version Publisher's PDF, also known as Version of record

Aalborg Universitet. Specification of a Two-Dimensional Test Case Nielsen, Peter Vilhelm. Publication date: 1990

The IEA Annex 20 Two-Dimensional Benchmark Test for CFD Predictions

Aalborg Universitet. CFD in Ventilation Design Nielsen, Peter Vilhelm. Publication date: 2009

Stratified Flow in a Room with Displacement Ventilation and Wall-Mounted Air Terminal devices Nielsen, Peter Vilhelm

Aalborg Universitet. A Study of Laminar Backward-Facing Step Flow. Davidson, Lars; Nielsen, Peter Vilhelm. Publication date: 1998

Experimental Evaluation of the Discharge Coefficient of a Centre-Pivot Roof Window Iqbal, Ahsan; Afshari, Alireza; Heiselberg, Per Kvols; Høj, Anders

Aalborg Universitet. Evaporation Controlled Emission in Ventilated Rooms. Topp, Claus; Nielsen, Peter V.; Heiselberg, Per. Publication date: 1997

Aalborg Universitet. Calculation of Vertical Temperature Gradients in Heated Rooms Overby, H.; Steen-Thøde, Mogens. Publication date: 1990

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Parametric Study on the Dynamic Heat Storage Capacity of Building Elements Artmann, Nikolai; Manz, H.; Heiselberg, Per Kvols

Lengweiler, P.; Nielsen, Peter Vilhelm; Moser, A.; Heiselberg, Per Kvols; Takai, H.

Sound absorption properties of a perforated plate and membrane ceiling element Nilsson, Anders C.; Rasmussen, Birgit

Aalborg Universitet. Flow Pattern in Ventilated Rooms with Large Depth and Width. Yue, Zou; Nielsen, Peter V. Publication date: 2000

Quantification of Uncertainty in Thermal building Simulation Brohus, Henrik; Haghighat, F.; Frier, Christian; Heiselberg, Per Kvols

Aalborg Universitet. Selection of Air Terminal Device. Nielsen, Peter V. Publication date: 1988

Aalborg Universitet. Numerical Prediction of Buoyant Air Flow in Livestock Buildings Svidt, Kjeld. Publication date: 1993

Aalborg Universitet. Seawall Overtopping Tests sea erosion study : Sohar Cornice Frigaard, Peter. Publication date: 1990

Tectonic Thinking Beim, Anne; Bech-Danielsen, Claus; Bundgaard, Charlotte; Madsen, Ulrik Stylsvig

Multi (building)physics modeling

Aalborg Universitet. Lecture 14 - Introduction to experimental work Kramer, Morten Mejlhede. Publication date: 2015

Analytical Studies of the Influence of Regional Groundwater Flow by on the Performance of Borehole Heat Exchangers

Modifications of the V2 Model for Computing the Flow in a 3D Wall Jet Davidson, L.; Nielsen, Peter Vilhelm; Sveningsson, A.

Aalborg Universitet. Simulation of Simple Test Case 2D1 Two-Dimensional Isothermal Forced Convection Skovgaard, M.; Nielsen, Peter Vilhelm

Kommerciel arbejde med WAsP

Aalborg Universitet. Land-use modelling by cellular automata Hansen, Henning Sten. Published in: NORDGI : Nordic Geographic Information

High and Low Reynolds number Measurements in a Room with an Impinging Isothermal Jet Skovgaard, M.; Hyldgaard, C. E. ; Nielsen, Peter Vilhelm

Development of a Dainish infrastructure for spatial information (DAISI) Brande-Lavridsen, Hanne; Jensen, Bent Hulegaard

Accelerating interior point methods with GPUs for smart grid systems

Aalborg Universitet. Empirical Test Case Specification Larsen, Olena Kalyanova; Heiselberg, Per Kvols. Publication date: 2006

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Velocity and Temperature Distribution in Flow from an Inlet Device in Rooms with Displacement Ventilation Jacobsen, T.V. ; Nielsen, Peter Vilhelm

Influence of the shape of surgical lights on the disturbance of the airflow Zoon, W.A.C.; van der Heijden, M.G.M.; Hensen, J.L.M.; Loomans, M.G.L.C.

Influence of turbulence model on thermal plume in indoor air flow simulation Zelensky, P.; Bartak, M.; Hensen, J.L.M.; Vavricka, R.

Aalborg Universitet. Comparative Test Case Specification Larsen, Olena Kalyanova; Heiselberg, Per Kvols. Publication date: 2007

Radioactivity in the Risø District January-June 2014

Unknown input observer based scheme for detecting faults in a wind turbine converter Odgaard, Peter Fogh; Stoustrup, Jakob

Reducing Uncertainty of Near-shore wind resource Estimates (RUNE) using wind lidars and mesoscale models

Aalborg Universitet. Bounds on information combining for parity-check equations Land, Ingmar Rüdiger; Hoeher, A.; Huber, Johannes

Aalborg Universitet. Mathematical Models for Room Air Distribution Nielsen, Peter Vilhelm. Published in: System Simulation in Buildings

Solar radiation and thermal performance of solar collectors for Denmark

Buoyancy Driven Natural Ventilation through Horizontal Openings Heiselberg, Per Kvols

Radioactivity in the Risø District July-December 2013

Validation and comparison of numerical wind atlas methods: the South African example

Characterization of microporous silica-based membranes by calorimetric analysis Boffa, Vittorio; Yue, Yuanzheng

Aalborg Universitet. All P3-equipackable graphs Randerath, Bert; Vestergaard, Preben Dahl. Publication date: 2008

Aalborg Universitet. Final Empirical Test Case Specification Larsen, Olena Kalyanova; Heiselberg, Per Kvols. Publication date: 2008

COMPARISON OF THERMAL HAND MODELS AND MEASUREMENT SYSTEMS

Estimation of Peak Wave Stresses in Slender Complex Concrete Armor Units

Design possibilities for impact noise insulation in lightweight floors A parameter study

Published in: Proceedings of IECON 2016: 42nd Annual Conference of the IEEE Industrial Electronics Society

Application of mesoscale models with wind farm parametrisations in EERA-DTOC

Aalborg Universitet. The number of independent sets in unicyclic graphs Pedersen, Anders Sune; Vestergaard, Preben Dahl. Publication date: 2005

Prediction of airfoil performance at high Reynolds numbers.

Modelling Salmonella transfer during grinding of meat

Lidar calibration What s the problem?

Tilburg University. Strongly Regular Graphs with Maximal Energy Haemers, W. H. Publication date: Link to publication

Numerical modeling of the conduction and radiation heating in precision glass moulding

Published in: 11th International Radiance Workshop, 12 September 2012, Copenhagen, Denmark

Benchmarking of optimization methods for topology optimization problems

Measurements of the angular distribution of diffuse irradiance

Double-Skin Facade in Low-Latitude: Study on the Absorptance, Reflectance, and Transmittance of Direct Solar Radiation

Online algorithms for parallel job scheduling and strip packing Hurink, J.L.; Paulus, J.J.

Atrium assisted natural ventilation of multi storey buildings

Winter Thermal Comfort in 19 th Century Traditional Buildings of the Town of Florina, in North-Western Greece

STUDY ON THE THERMAL PERFORMANCE AND AIR DISTRIBUTION OF A DISPLACEMENT VENTILATION SYSTEM FOR LARGE SPACE APPLICATION

The energy performance of an airflow window

GIS Readiness Survey 2014 Schrøder, Anne Lise; Hvingel, Line Træholt; Hansen, Henning Sten; Skovdal, Jesper Høi

TREES Training for Renovated Energy Efficient Social housing

Citation (APA): Holm, E., Frøsig, L., & Sidhu, R. (Eds.) (2006). Theory of sampling. (NKS-122).

Graphs with given diameter maximizing the spectral radius van Dam, Edwin

Citation for published version (APA): Burcharth, H. F. (1988). Stress Analysis. Aalborg: Department of Civil Engineering, Aalborg University.

A note on non-periodic tilings of the plane

Published in: UrbanRain09 : 8th International Workshop on Precipitation in Urban Areas : St. Moritz, Switzerland

Concept Testing of a Simple Floating Offshore Vertical Axis Wind Turbine

Natural Ventilation. CFD modelling of a double-skin facade. Huw Birch. Supervisor: Abigail Hathway

De Prisco, Renato; Comunian, Michele; Grespan, Franscesco; Piscent, Andrea; Karlsson, Anders

A beam theory fracture mechanics approach for strength analysis of beams with a hole

Neutronics calculations for the ITER Collective Thomson Scattering Diagnostics

Comparisons of winds from satellite SAR, WRF and SCADA to characterize coastal gradients and wind farm wake effects at Anholt wind farm

ROOM AVERAGE VELOCITY EQUATION A TOOL TO IMPROVE DESIGN OF THERMAL COMFORT CONDITIONS

Simulating wind energy resources with mesoscale models: Intercomparison of stateof-the-art

Embankment dam seepage assessment by resistivity monitoring

Generating the optimal magnetic field for magnetic refrigeration

Design of Robust AMB Controllers for Rotors Subjected to Varying and Uncertain Seal Forces

Irregular Wave Forces on Monopile Foundations. Effect af Full Nonlinearity and Bed Slope

A Note on Powers in Finite Fields

Global Wind Atlas validation and uncertainty

A numerical study of vortex-induced vibrations (viv) in an elastic cantilever

The dipole moment of a wall-charged void in a bulk dielectric

A comparison study of the two-bladed partial pitch turbine during normal operation and an extreme gust conditions

INSTITUTTET FOR BYGNINGSTEKNIK DEPT. OF BUILDING TECHNOLOGY AND STRUCTURAL ENGINEERING AALBORG UNIVERSITET AAU AALBORG DANMARK

An Equivalent Source Method for Modelling the Lithospheric Magnetic Field Using Satellite and Airborne Magnetic Data

Advantages and Challenges of Superconducting Wind Turbine Generators

Transcription:

Aalborg Universitet ndoor Climate of Large Glazed Spaces Hendriksen, Ole Juhl; Madsen, Christina E.; Heiselberg, Per Kvols; Svidt, Kjeld Publication date: 1996 Document Version Publisher's PDF, also known as Version of record Link to publication from Aalborg University Citation for published version (APA): Hendriksen, O. J., Madsen, C. E., Heiselberg, P., & Svidt, K. (1996). ndoor Climate of Large Glazed Spaces. Aalborg: Dept. of Building Technology and Structural Engineering. ndooor Environmental Technology, No. 63, Vol.. R9655 General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights.? Users may download and print one copy of any publication from the public portal for the purpose of private study or research.? You may not further distribute the material or use it for any profit-making activity or commercial gain? You may freely distribute the URL identifying the publication in the public portal? Take down policy f you believe that this document breaches copyright please contact us at vbn@aub.aau.dk providing details, and we will remove access to the work immediately and investigate your claim. Downloaded from vbn.aau.dk on: juli 8, 218

NSTTUTTET FOR BYGNNGSTEKNK DEPT. OF BULDNG TECHNOLOGY AND STRUCTURAL ENGNEERNG AALBORG UNVERSTET AAU AALBORG DANMARK NDOOR ENVRONMENTAL TECHNOLOGY PAPER NO. 63 Presented at the 4th European Conference on Solar Energy in Architecture and Urban Planning, Berlin, Germany, March 1996. J. HENDRKSEN, C. E. MADSEN, P. HESELBERG & K. SVDT NDOOR CLMATE OF LARGE GLAZED SPACES DECEMBER 1996 SSN 1395-7953 R9655

The papers on NDOOR ENVRONMENTAL TECHNOLOGY are issued for early dissemination of research results from the ndoor Environmental Technology Group at the University of Aalborg. These papers are generally submitted to scientific meetings, conferences or journals and should therefore not be widely distributed. Whenever possible reference should be given to the final publications (proceedings, journals, etc.) and not to the paper in this series. Printed at Aa,Jborg University

NSTTUTTET FOR BYGNNGSTEKNK DEPT. OF BULDNG TECHNOLOGY AND STRUCTURAL ENGNEERNG AALBORG UNVERSTET AAU AALBORG DANMARK NDOOR ENVRONMENTAL TECHNOLOGY PAPER NO. 63 Presented at the 4th European Conference on Solar Energy in Architecture and Urban Planning, Berlin, Germany, March 1996. J. HENDRKSEN, C. E. MADSEN, P. HESELBERG & K. SVDT NDOOR CLMATE OF LARGE GLAZED SPACES DECEMBER 1996 SSN 1395-7953 R9655

NDOOR CLMATE OF LARGE GLAZED SPACES Ole Juhl Hendriksen and Christina E. Madsen Esbensen Consulting Engineers FDC Teknikerbyen 38 OK - 283 Virum Per Heiselberg and Kjeld Svidt Aalborg University Sohngaardsholmsvej 57 DK - 9 Aalborg ABSTRACT: n recent years large glazed spaces has found increased use both in connection with renovation of buildings and as part of new buildings. One of the objectives is to add an architectural element, which combines indoor- and outdoor climate. n order to obtain a satisfying indoor climate it is cruicial at the design stage to be able to predict the performance regarding thermal comfort and energy consumption. This paper focus on the practical implementation of Computational Fluid Dynamics (CFD) and the relation to other simulation tools regarding indoor climate. KEYWORDS: Natural ventilation, Computer simulation models, Atrium, Daylight evaluation, Thermal comfort Project description One of the important issues in design of large glazed spaces is determination of the air movements in the room and especially in the occupied zone. This project is carried out as a case study, and comprises a monitoring programme and simulations using CFD for a natural ventilated atrium. Furthermore the daylight conditions and the energy consumption for heating, ventilation and lighting will be analyzed in the project. Building description Sukkertoppen is an old sugar refinery in Copenhagen, which was redeveloped into a multi-media house in 1992. A new building was added south of the existing building, and the two buildings are coupled with a glazed atrium. The purpose of the atrium is to reduce the space heating load of the buildings, and to improve the daylight conditions in the attached buildings. This atrium is used as circulation area and has no permanent occupation. The atrium is heated to 16-8 C during the winter season, and is naturally ventilated during summer season.,~ Outline of the atrium with openings The monitoring programme consists of measurements of surface- and air temperatures for a six month period and detailed air flow measurements for two short-term periods during summer and winter conditions. The measurements are used as boundary conditions for CFD simulations. and for verification of the CFD models. The programme FLOVENT has been used for the CFD analysis. West end wall of the atrium Sukkertoppen. The dimensions of the atria is x 18.5 x 58 meter. The openings are placed in the end walls and at the top of the roof. All glazed surfaces facing the outdoor air are low-energy glazing with an U-value of 1.6 W/m'K.

ndoor Climate Summer Natural ventilation with air supply through openings in end-walls, and outflow through the top of the roof. The airflow is characterized by moderate thermal stratification. --- - ---.. Ventilation rate: 469 m3/h Air change rate: 4.9 /h Outdoor temperature: 2 C Vertical temperature gradient 2 ~----------- 16 +-----------------=-~ 1: :~~~~~~~~~~~~~~~~~-=~ -:-fi,'- o+--+----r---- ----i, r-------t--+--+ 12 14 16 18 2 22 24 1 Temperature ["C] l-o-- Meauserements --CFD Percentage of dissat:isf"ied ~±:Jl:t' ',. ContoUJ; Teapa.ratuz;a 5 24 2 ~ ~~~ ;;:;;~ 1(3-21 2 71 2 6 2 ll. BD -~---------~ 6 1-------------1 4Q 1--~-c---n~O 2 +-~--=-~~-~~~~ Q v-/'''v 1 2 3 4 so 6 Distance 'from west-end [m]! o Measurements Mm- - CFD!..,..]. & + :oc-3. BOOOE+OO. 2 TLCHZ.JU'CS Winter nfiltration through surfaces facing outdoor. The temperature measurements and a smoke test had shown mixed air, but the CFD model has a limited size, and lack of abilities to show the situation of mixed air due to infiltration. Ventilation rate: Air change rate: Outdoor temperature: 335 m3/h.35 /h C 1' r l :1'1 T.-.-- [ ;: Cl a; 2 16 12 8 Vertical temperature gradient ~ A-- - 4 "-- -- ---~ -+-~--. 12 14 16 18 2 22 24 Tern perature [:.9, : -<>--Measurements -- CFD Percentage of dissatisfied.'----- - - ------- ------- -- Vactor Contou:t TaJilJMiratura.4 1 19..343 18..286 17..229. 16..171 ::1 15. O.lU 1::; 14..57 13.. 12. 1 8 ~ a. 6 4. 2 x-3. 81+ x-3. BOOOE+OO 1 2 3 4 5 6 Distance from west-end [rn] Job: ).{RBV)BL Title: ukkertoppen.2 Ra! Vector F1D<ER1CS : Measurements - CFD i 2

' ~ # ~ - - - ' \ \ ' Natural ventilation The capacity and the temperature conditions have been analyzed with CFD for three different configurations of natural ventilation at moderate summer conditions. ~ ~~~- ~~ ~~~ o 1oo '"" ztzoo 35 24 2 5 2 6 2 1. Openings in side walls This configuration results in satisfying temperature conditions in the occupied zone, but leads to a high temperature gradient in the top of the atrium due to a pile of hot air. V c~r Contour Ta::;>c.ratu r :::: 35 :: 24 ::: 2 :::: ~~ :: ::: l OO 2! 2 5 2. 6 ODD 2 2. Openings in top of the roof and the of the side walls This configuration is characterized by the lowest ventilation rate and no temperature gradient, which indicates mixing of the air. 1 ""1.25E-1 r l. 251:-l.2 b! Vactor PLCH Jt!CS 3. Openings in top of the roof and lower part of the side walls This configuration has the largest distance between the openings, which results in the highest ventilation rate and the lowest tern peratures. - ~ -..... \ (...::::: : ::! T2l' :u,,,..... '. '....,,, ~::::d,,,... ' '' ',,. ol 1... ''' '',.,tt ::::!.25.2 f :::::1.5. r. 1.25~-1 Contour T~atur H.2 23. 6 23. 22. ol 21. 1 21.2 2.6 2. l"'l. ZSDOE-1 3

Capacity :c 3 14~ ;::;.c E. 25 12 :::::. ll ll 2 1 ~ -;;;...... 8 ll c 15 Cl 6 c :;::; cu.!!! 1 4.c u c 5... 2 ll ~ > 2 3 2 16... 12.c Cl ll 8 :r: 4 Vertical temperature gradient J 11 i : r='-r- - --J 2 21 22 23 24 Temperature [ C) Daylighting n order to improve the daylight conditions in the adjacent rooms at the lower floors, the window area has been increased. This increased window area was possible due to the use of low-energy glazing at the surfaces facing the outdoor, and without an increased heating load for the building. Calculations have shown that the daylight factor is reduced at the front of the room and increased towards the back of room. This is very advantageous since both the daylight availability deep in the room is increased and the contrast ratio is reduced. ntegration of simulation tools An important part of the CFD analysis is to estimate the boundary conditions, in order to obtain useful results for ventilation and air flow. Dynamic thermal simulation programmes can be used to determine the surface temperatures and the energy balance for a room, and the results can be transferrred to a CFD programme. Furthermore the air change rate calculated by CFD can be transferred back to the dynamic thermal simulation programme in order to improve the determination of the thermal performance and energy balance for the room. Conclusion CFD is a powerful tool to predict or evaluate ventilation and indoor climate of large glazed spaces. The boundary conditions for the CFD simulations should be treated carefully in order to obtain useful results. The analysis of the indoor climate for the naturally ventilated atrium has shown that it is possible to obtain a satisfying indoor climate during the summer period. n the winter period the PO index is rather high at the end walls due to cold draught, especially by the east end-wall due to wind pressure. Further information Please contact: Aalborg University Kjeld Svidt e-mail: Tel: Fax: i6ks@civil.auc.dk +45 98 15 85 22 +45 98 14 82 43 Esbensen Ole Juhl Hendriksen e-mail: esbensen@inet.uni-c.dk Esbensen Consulting Engineers FDC: Teknikerbyen 38, DK-283 Virum Tel.: +45 45 83 42 24 Fa.x +45 45 83 68 34 Private Danish consulting engineering company with more than 3 years of experience in energy research, development and realization within: Energy efficient building design Advanced daylight and energy simulations Passive and active solar energy Photovoltaic systems Esbensen is also participating in several national and international R&D projects in the fields of daylighting and utilization of solar energy. 4

PAPERS ON NDOOR ENVRONMENTAL TECHNOLOGY PAPER NO. 34: T. V. Jacobsen, P. V. Nielsen: Numerical Modelling of Thermal Environment in a Displacement- Ventilated Room. SSN 92-7513 R9337. PAPER NO. 35: P. Heiselberg: Draught Risk from Cold Vertical Surfaces. SSN 92-7513 R9338. PAPER NO. 36: P. V. Nielsen: Model Experiments for the Determination of Airflow in Large Spaces. SSN 92-7513 R9339. PAPER NO. 37: K. Svidt: Numerical Prediction of Buoyant Air Flow in Livestock Buildings. SSN 92-7513 R9351. PAPER NO. 38: K. Svidt: nvestigation of nlet Boundary Conditions Numerical Prediction of Air Flow in Livestock Buildings. SSN 92-7513 R947. PAPER NO. 39: C. E. Hyldgaard: Humans as a Source of Heat and Air Pollution. SSN 92-7513 R9414. PAPER NO. 4: H. Brohus, P. V. Nielsen: Contaminant Distribution around Persons in Rooms Ventilated by Displacement Ventilation. SSN 92-7513 R9415. PAPER NO. 41: P. V. Nielsen: Air Distribution in Rooms - Research and Design Methods. SSN 92-7513 R9416. PAPER NO. 42: H. Overby: Measurement and Calculation of Vertical Temperature Gradients in Rooms with Convective Flows. SSN 92-7513 R9417. PAPER NO. 43: H. Brohus, P. V. Nielsen: Personal Exposure in a Ventilated Room with Concentration Gradients. SSN 92-7513 R9424. PAPER NO. 44: P. Heiselberg: nteraction between Flow Elements in Large Enclosures. SSN 92-7513 R9427. PAPER NO. 45: P. V. Nielsen: Prospects for Computational Fluid Dynamics in Room Air Contaminant Control. SSN 92-7513 R9446. PAPER NO. 46: P. Heiselberg, H. Overby, & E. Bj~rn: The Effect of Obstacles on the Boundary Layer Flow at a Vertical Surface. SSN 92-7513 R9454. PAPER NO. 47: U. Madsen, G. Aubertin, N.. Breum, J. R. Fontaine & P. V. Nielsen: Tracer Gas Technique versus a Control Box Method for Estimating Direct Capture Efficiency of Exhaust Systems. SSN 92-7513 R9457. PAPER NO. 48: Peter V. Nielsen: Vertical Temperature Distribution in a Room with Displacement V:entilation. SSN 92-7513 R959. PAPER NO. 49: Kjeld Svidt & Per Heiselberg: CFD Calculations of the Air Flow along a Cold Vertical Wall with an Obstacle. SSN 92-7513 R951. PAPER NO. 5: Gunnar P. Jensen & Peter V. Nielsen: Transfer of Emission Test Data from Small Scale to Full Scale. SSN 1395-7953 R9537. PAPER NO. 51: Peter V. Nielsen: Healthy Buildings and Air Distribution in Rooms. SSN 1395-7953 R9538.

PAPERS ON NDOOR ENVRONMENTAL TECHNOLOGY PAPER NO. 52: Lars Davidson & Peter V. Nielsen: Calculation of the Two Dimensional Airflow in Facial Regions and Nasal Cavity using an Unstructured Finite Volume Solver. SSN 1395-7953 R9539. PAPER NO. 53: Henrik Brohus & Peter V. Nielsen: Personal Exposure to Contaminant Sources in a Uniform Velocity Field. SSN 1395-7953 R954. PAPER NO. 54: Erik Bjrn & Peter V. Nielsen: Merging Thermal Plumes in the ndoor Environment. SSN 1395-7953 R9541. PAPER NO. 55: K. Svidt, P. Heiselberg &. J. Hendriksen: Natural Ventilation in Atria- A Case Study. SSN 1395-7953 R9647. PAPER NO. 56: K. Svidt & B. Bjerg: Computer Prediction of Air Quality in Livestock Buildings. SSN 1395-7953 R9648. PAPER NO. 57: J. R. Nielsen, P. V. Nielsen & K. Svidt: Obstacles in the Occupied Zone of a Room with Mixing Ventilation. SSN 1395-7953 R9649. PAPER NO. 58: C. Topp & P. Heiselberg: Obstacles, an Energy-Efficient Method to Reduce Downdraught from Large Glazed Surfaces. SSN 1395-7953 R965. PAPER NO. 59: L. Davidson & P. V. Nielsen: Large Eddy Simulations of the Flow in a Three-Dimensional Ventilated Room. SSN 1395-7953 R9651. PAPER NO. 6: H. Brohus & P. V. Nielsen: CFD Modeis of Persons Evaluated by Full-Scale Wind Channel Experiments. SSN 1395..:7953 R9652. PAPER NO. 61: H. Brohus, H. N. Knudsen, P. V. Nielsen, G. Clausen & P.. Fanger: Perceived Air Quality in a Displacement Ventilated Room. SSN 1395-7953 R9653. PAPER NO. 62: P. Heiselberg, H. Overby & E. Bjrn: Energy-Efficient Measures to Avoid Downdraft from Large Glazed Facades. SSN 1395-7953 R9654. PAPER NO. 63:. J. Hendriksen, C. E. Madsen, P. Heiselberg & K. Svidt: ndoor Climate of Large Glazed Spaces. SSN 1395-7953 R9655. \ PAPER NO. 64: P. Heiselberg: Analysis and Prediction Techniques. SSN 1395-7953 R9656. PAPER NO. 65: P. Heiselberg & P. V. Nielsen: Flow Element Models. 1395-7953 R9657. SSN PAPER NO. 66: Erik Bjrn & P. V. Nielsen: Exposure due to nteracting Air Flows between Two Persons. SSN 1395-7953 R9658. PAPER NO. 67: P. V. Nielsen: Temperature Distribution in a Displacement Ventilated Room. SSN 1395-7953 R9659. PAPER NO. 68: G. Zhang, J. C. Bennetsen, B. Bjerg & K. Svidt: Analysis of Air Movement Measured in a Ventilated Enclosure. SSN 139995-7953 R966. Department of Building Technology and Structural Engineering Aalborg University, Sohngaardsholmsvej 57. DK 9 Aalborg Telephone: +45 9635 88 Telefax: +45 9814 8243