Ackred. nr 1678 Kalibrering ISO/IEC 17025

Similar documents
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. J. A. KING & COMPANY, LLC 8813 Old Craft Road Olive Branch, MS CONNIE FOSTER PHONE:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

ACCREDITED LABORATORY. INSPECTION MEASUREMENT COMPANY Wyoming, MI

Physical Properties Testing Technical Bulletin

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. ADVANCED TECHNOLOGY SERVICES HMA 1800 Honda Drive Lincoln, AL Lasheila Hayes Phone:

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

ACCREDITED CALIBRATION AND MEASUREMENT CAPABILITY SCOPE. Ring gaugeф(50~100)mm U=1.1 μm

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

Certificate of Accreditation

Certificate of Accreditation

Certificate of Accreditation

Rampura Tools.

Measuring methods. Measuring tools. Measuring methods. Measuring tools. Measuring methods. Measuring tools. Measuring methods. 5. Smoothness testing

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

Interlaboratory Comparison & Proficiency Testing Program

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

COMMON MISTAKES IN DIMENSIONAL CALIBRATION METHODS

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

Certificate of Accreditation

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

TR CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF DIMENSIONAL METROLOGY

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Interlaboratory Comparison & Proficiency Testing Program

Determination of sound absorption coefficient in impedance tubes according to ISO (2 appendices)

Interlaboratory Comparison & Proficiency Testing Program

TRACEABILITY STRATEGIES FOR THE CALIBRATION OF GEAR AND SPLINE ARTEFACTS

PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. PRODUCT: SUN TUNNEL Domes TYPES: Acrylic and Polycarbonate

REALIZATION OF HUMIDITY STANDARD FACILITY USING TWO-PRESSURE HUMIDITY GENERATOR AND HUMIDITY CHAMBER

CALIBRATION CENTER. Republic of Turkey. Ministry of Forestry and. Water Affairs. Turkish State Meteorological Service.

CERTIFICATE OF ACCREDITATION

METHODS FOR CERTIFYING MEASUREMENT EQUIPMENT. Scott Crone

New Thermometer Guidance Document from AASHTO Accreditation Program. Maria Knake Asphalt Binder ETG Meeting May 10, 2018

2.1. Accuracy, n- how close the indication of the thermometer is to the true value.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. GREENSLADE & CO., INC Wenneca Avenue Fort Worth, TX Larry Borowski Phone:

Mason Technology Ltd

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z ALPHAGAGE th Avenue Rockford, IL James Hoard Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

REPORT issued by an Accredited Testing Laboratory

Emission measurements according to, M1 (3 appendices)

The Fundamentals of Moisture Calibration

Strain Measurement Techniques for Composite Coupon Testing

台灣黑馬牌校正器類 CALIBRATOR METROLOGY

REPORT issued by an Accredited Testing Laboratory

Humidity Calibration Solutions

Topic 1.2 Measurement and Uncertainties Uncertainty and error in measurement. Random Errors

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Certificate of Accreditation

COMPLETION AND MEASUREMENT UNCERTAINTY BUDGET OF THE MULTI-COMPONENT MEASURING DEVISE FOR FORCE UP TO 1 MN AND TORQUE UP TO 2 KN M

World Meteorological Organization

Humidity Calibration Solutions

SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY CO., LTD

Certificate of Accreditation

STATUS OF THE WIGOS DEMONSTRATION PROJECTS

Training Benefits Adding Values to Your Systems/ Organization through: Potential Attendees These Courses have been designed for;

Introduction of RIC Tsukuba (Japan, RAII)

Increased Requirements for Higher Nominal Forces, Necessities and Possibilities to Measure Them

CEEN 3320 Behavior & Properties of Engineering Materials Laboratory Experiment No. 1 Measurement Techniques

CONTENT 2. ORGANIZATION 3. SERVICES. instruments. (3)Activities of RIC Tsukuba

Loadcell Calibration - Evaluation of Uncertainties

Scope of Accreditation For ISOLAB Inc. Calibration

TYPICAL PRESSURE MEASUREMENT UNCERTAINTY DEFINED BY AN FPG8601 FORCE BALANCED PISTON GAUGE

Technical Protocol of the CIPM Key Comparison CCAUV.V-K5

Engineering Metrology and Instrumentation

MANUFACTURE OF STRAIN GAUGES & TRANSDUCERS

Infrared Thermometer Calibration A Complete Guide

Natural Exposure Testing VS Accelerated Weathering... The Right Choice.

Certificate of Accreditation

Accurate Measurement of Transmittance and Reflectance for Engineering Applications

Measurement & Uncertainty - Basic concept and its application

Morehouse. Edward Lane, Morehouse Instrument Company 1742 Sixth Ave York, PA PH: web: sales:

CALIBRATION CERTIFICATE # 503

Height Master Page 343. Check Master Page 347. Calibration Tools Page 352

Certificate of Accreditation

Experiment P28: Conservation of Linear and Angular Momentum (Smart Pulley)

Measurement Uncertainty in Mechanical Testing

M-3: Statics & M-10 Elasticity

Certificate of Accreditation

The objective of this experiment is to investigate the behavior of steel specimen under a tensile test and to determine it's properties.

SHENZHEN SEM.TEST TECHNOLOGY CO., LTD. 1/F, BUILDING A, HONGWEI INDUSTRIAL PARK, LIUXIAN 2ND ROAD BAO'AN DISTRICT SHENZHEN (518101), CHINA

PHY 111L Activity 9 Moments of Inertia

Lecture - 2A Instruments-I

TEST METHOD FOR DETERMINING BREAKAWAY FORCE OF A MAGNET

PURCHASE OF LAB EQUIPMENTS FOR CHEMISTRY [Kindly enclose a signed copy of this document along with the TENDER Document]

Display Calibrations and Uncertainties. Christine Wall National Physical Laboratory

Spacecraft Structures

Edgetech Instruments Inc.

Transcription:

Calibration Tvinnargatan 25 SE-507 30 Brämhult SWEDEN Phone: +4633 22 56 30 info@kalibrera.se www.kalibrera.se Ackred. nr 1678 Kalibrering ISO/IEC 17025 Our calibration lab is accredited by Swedac for: Length Mass Temperature Force Pressure Hardness Elongation Speed Accredited calibration of high forces up to 500 kn. Our calibration laboratory is equipped with a pressure and reference gauge to handle traceable calibration of higher forces up to 500 kn, in both tension and compression load. The reference gauge can be used both in the laboratory and in the field. Calibration of portable spectro photo meters and gloss meters. We can calibrate BYK-Gardner s instruments, such as spectro-guide, micro-gloss and wave-scan, as you can see in the image on the right. How can you get lower costs for the calibration? Calibration costs today can for both the internal and the external calibration become a considerable part of the cost for quality work. Employing external calibration services can save your company money. Let us calculate for your calibration work and give you a quotation. Don t forget to consider that it might be less expensive for your company to let us do the calibration you perform internally as well. We are experts in calibration and have the necessary equipment and education as well as the accreditation. What is calibration? Calibration of a measuring instrument is to determine the deviation in measuring values between the instrument and a traceable value. What is adjustment? Adjustment is to adjust an instrument so it will show as close as possible to the correct value. After this the calibration is performed to determine the remaining measuring error. What is traceability? During a traceability calibration a standard that is calibrated against the Swedish standards for the current unit is used. The Swedish standards are in their turn calibrated against the international standards that is handled of a national metrology centre for each unit. A national metrology centre is a government laboratory that is the best in the country to measure a certain unit. Most of the national metrology centre in Sweden are at SP, Technical Research Institute of Sweden, located in Borås. What is measurement uncertainty? The measurement uncertainty is the uncertainty in the calibration result that is remaining after calibration. The uncertainty is calculated for each measuring situation. In the uncertainty are among other things the standards accuracy, the calibrated instruments resolution as well as ambient factors such as temperature etc included. b-calib_23_1801 What is accredited calibration? An accredited calibration is performed according to a method that is approved by the Swedish authority SWEDAC. Accredited calibration is performed of a laboratory who has a quality system and methods that are approved and continuously controlled by SWEDAC. SWEDAC is the Swedish Board for Accreditation. The general laboratory for calibration at 23 C. In addition to this we have a constant room for calibration of length at 20 C ± 0,5 C, and a room for temperature calibration. info@kalibrera.se www.kalibrera.se

Length Length is the unit where we have most methods for different types of instruments. The following measurements relate to accredited cali bra tion methods but but we can usually calibrate greater measurements with traceability to international standards. Micrometers, calipers, dial indicators, measuring scales, measuring tapes and surface plates are calibrated both on-site at the customers facility and in our calibration laboratory. Gauge blocks, rings and gauges are only calibrated in our calibration laboratory since there are special demands on both the environment where it s done and the equipment that is used. Calibration of gauge blocks. Calibration of thread rings gauges with measuring instrument Labconcept Nano. Rings and gauges Calibration up to 250 mm. Gauge blocks Calibration of gauge blocks up to 500 mm. Micrometers We calibrate micrometres up to 500 mm. Calipers We calibrate calipers up to 1 m. Dial Indicators Calibration of analogue and digital dial indicators up to 100 mm. Measuring scales and measuring tapes We calibrate up to 30 m long measuring scales and measuring tapes. Surface plates Flatness calibration up to 5 000 mm. Remember that a surface plate is a reference surface. These are usually calibrated in the field. Height gauges Height gauges and profile projectors are only calibrated in the field and this is usually done in the context of the calibration of the surface plates. Surface roughness When we calibrate the roughness of a surface we use a surface roughness meter with traceable adjustments normal. Angles and protractors These are calibrated with one of our developed methods. Tester for dial indicators. Calibration of surface plates. Instrument for calibration of surface roughness normals. Profile projector. 2 Elastocon Mätcentrum Calibration

Temperature In our calibration laboratory we usually use a liquid bath for calibration of temperature sensors, this gives the best accuracy. We can also calibrate in air, i.e. when the sensor cannot withstand liquid. Furthermore we can calibrate heating cabinets and liquid baths. On-site we use block calibrators which give a slightly less accuracy, but is smoother for use in the field. Pressure We offer calibration of pressure gauges from -80 kpa up to 40 MPa. This is done both in the field and in our calibration laboratory. Calibration of temperature in miniature liquid bath. Mass Balances are calibrated almost only in the field, this is due to the fact that display of mass is greatly affected by the ambient environment, i.e. gravity and air draughts. We are accredited Calibration of laboratory scale. for calibration of balances/scales up to 150 kg. Scales up to 5 000 kg we can calibrate with trace ability according to our own method. Hardness Hardness tester for rubber and plastic in the scales IRHD and Shore are calibrated both in our laboratory and in the field. Reference blocks for Shore and IRHD are calibrated in our laboratory. Calibration of manometers. Calibration of hardness tester. Elastocon Mätcentrum Calibration 3

Force We calibrate tensile testers up to 500 kn and then the calibration of speed and tension can be included. We can calibrate other types of force measure instrument such as load cells with amplifiers as well. Speed This calibration is mainly performed on tensile testers. Elongation Just as for speed this is calibration mainly for tensile testers. But we can manage other types of extenso meters as well. Time As time reference we have a computer that is trace able calibrated against an atomic clock at RISE The Swedish Research Institute. Relative humidity (RH) Calibration of tensile tester. Hygrometers are calibrated in our laboratory, whilst climate chambers most often are calibrated in the field for practical reasons. Gas flows Calibration of hygrometer. Flow meters for ageing cabinets and analytical instruments we can calibrate for flows up to 20 l/min. Calibration of flow meter with float. Torque We calibrate torque wrenches up to 3 000 Nm. In cooperation with another calibration company we can offer accredited calibration as well. Electrical units We calibrate resistivity testers and conductivity meters. In cooperation with another calibration company we can also offer calibration of other instruments such as multimeters as well. Conductivity meters 4 Elastocon Mätcentrum Calibration

Colour and gloss We can calibrate spectrophotometers and gloss meters that measure with different angles. Calibration and service of weathering equipment We offer calibration and service of Q-Lab s equipment for weathering, light stability, and corrosion for customers in Sweden, Norway and Denmark. Above: BYK-Gardner s gloss meter micro-gloss is one kind of instrument that we calibrate. Below, from the left: the coulor spectrophotometer spectro-guide and the Orange Peel/DOI meter wave-scan. Calibration and service of a QUV Accelerated Weathering Tester. Transport containers Calibrating regularly? You can sign an agreement with Elastocon Mätcentrum about your calibration! If you do, we will provide you with two transport containers with interior, to secure the transport of your instruments. Measurement tasks We perform measurements in our coordinate measuring machine. Measuring range: 700*600*450 mm. Qualified measurements of short sample series, spot-checks, reference samples, prototypes, control measurements, third party measurements and measure ment of tools and fixtures. We can also assist with technical measuring advice. Measurements in our coordinate measuring machine. Elastocon Mätcentrum Calibration 5

What units can we calibrate? Unit Measuring range Measuring uncertainty Example of instrument Length 0,5 mm 100 mm ± 0,07 µm 0,15 µm Gauge blocks, steel 125 mm 500 mm ± 0,46 µm 0,70 µm Gauge blocks, steel 1 mm 100 mm ± 1,5 µm Cylindrical gauges 1,5 mm 250 mm ± 1,1 µm 1,8 µm Cylindrical rings 0,15 mm 20 mm ± 1,5 µm Measurement threads and measurement sticks 25 mm 500 mm ± 1,8 µm 2,7 µm Control measure 0 mm 150 mm ± 3 µm Micrometers 150 mm 500 mm ± 9,0 µm 16,0 µm Micrometers 6 mm 100 mm ± 13,6 µm 4,8 µm 3 point Micrometer 0 mm 300 mm ± 10,0 µm 35,0 µm Caliper 300 mm 1 000 mm ± 35,0 µm 55,0 µm Caliper 0 mm 100 mm ± 2,0 µm Dial indicator 0 mm 1 000 mm ± 0,3 µm 0,6 mm Steel scale 0 mm 8 m ± 0,5 mm Measuring tape 0 mm 30 m ± 1,3 mm Measuring tape Up to 100 mm ± 5,0 µm Thread gauges 3 mm 125 mm ± 4,7 µm Thread rings Up to 5 000 mm ± 4,8 µm 6,1 µm Surface plates Mass 1 g 10 g ± 0,017 mg ± 0,031 mg Balances, Scales 10 g 100 g ± 0,031 mg ± 0,08 mg 0,1 kg 1 kg ± 0,08 mg ± 0,8 mg 1 kg 10 kg ± 0,8 mg ± 8 mg 10 kg 20 kg ± 8 mg ± 9 mg 20 kg 80 kg ± 0,6 g ± 1,3 g 80 kg 150 kg ± 2,4 g ± 2,4 g 150 kg 5 000 kg ± 0,5 kg ± 1,0 kg * Temperature -70 C -30 C ± 0,5 C -30 C 0 C ± 0,1 C Controllers, Indicators 0 C 200 C ± 0,05 C Temperature instruments 200 C 300 C ± 0,2 C 300 C 400 C ± 1,0 C 20 C 200 C ± 0,2 C applicable in the field 200 C 250 C ± 0,5 C applicable in the field 250 C 400 C ± 1,0 C applicable in the field 400 C 1 000 C ± 3,0 C * Hardness Shore durometers 10 90 Sh ± 0,5 Sh Shore durometers IRHD hardness meters 10 100 IRH ± 0,5 IRH IRHD hardness meters Reference rubber 10 95 ± 1 Reference rubber block block * non accredited method 6 Elastocon Mätcentrum Calibration

Swedens national kilogram no 40 from 1889. The old retired speaking clock service is found at SP, Technical Research Institute of Sweden located in Borås where you can find the new speaking clock service as well. Unit Measuring range Measuring uncertainty Example of instrument Force 0,1 N 10 N Tension & Compression ± 0,002 N Load Cells, Tensile tester 10 N 50 N Tension & Compression ± 0,007 N 50 N 200 N Tension & Compression ± 0,03 N 200 N 500 N Tension & Compression ± 0,07 N 500 N 2000 N Tension & Compression ± 0,8 N 2 kn 10 kn Tension & Compression ± 8 N Load cells larger than 2 kn can only 10 kn 20 kn Tension & Compression ± 15 N be calibrated within their own load frame, 20 kn 30 kn Tension & Compression ± 43 N typically carried out on-site. 30 kn 50 kn Tension & Compression ± 65 N 50 kn 100 kn Tension & Compression ± 100 N 100 kn 500 kn Tension & Compression ± 500 N Elongation 5 1 200 % på 1 0 25 mm 0,01 % Extensometer 5 1 200 % på 1 0 20 mm 0,02 % 10 1 200 % på 1 0 10 mm 0,06 % Speed 1 10 mm/min 0,06 mm/min Tensile tester 10 25 mm/min 0,13 mm/min 25 50 mm/min 0,25 mm/min 50 100 mm/min 0,50 mm/min 100 200 mm/min 1,0 mm/min 200 250 mm/min 1,3 mm/min 250 500 mm/min 2,5 mm/min Pressure -10 kpa -80 kpa ± 0,4 kpa Pressure Gauge, Manometer -1kPa -10 kpa ± 20 Pa -100 Pa -1 kpa ± 4 Pa -3 Pa -100 Pa ± 1,0 Pa 3 Pa 100 Pa ± 0,5 Pa 100 Pa 1 kpa ± 2 Pa 1 kpa 10 kpa ± 10 Pa 10 kpa 200 kpa ± 0,2 kpa 200 kpa 8 MPa ± 5 kpa 8 MPa 20 MPa ± 26 kpa 20 MPa 40 MPa ± 28 kpa Time 1s 16 h ± 0,21 s * Timer etc Humidity 0 100 % RF ± 1,0 % RF * Hygrometer (0 85 C) Climat Chambers * non accredited method Elastocon Mätcentrum Calibration 7

Unit Measuring range Measuring uncertainty Example of instrument Angle 0 360 * Goniometer Protractors Fixed angles Torque 0,2 3 000 Nm * Torque wrenches Gloss 0 100 % 0,5 % * Gloss meter Electrical units (example) Resistivity tester Multimeter Small gas flows 0,01-20 l/min * * non accredited method Contacts Jonas Nilsson Calibration Manager +46 33 22 56 36 jonas.nilsson@elastocon.se Ann-Christin Johansson Calibration Laboratory Manager +46 33 22 56 39 ann-christin.johansson@elastocon.se Niklas Vernholt Field Calibration +46 33 22 56 35 niklas.vernholt@elastocon.se Lennart Hermansson Sales, Calibration +46 33 22 56 43 lennart.hermansson@elastocon.se Caroline Blomqvist Length calibration +46 33 22 56 47 caroline.blomqvist@elastocon.se To the right, the auditor from Swedac examines our quality system together with Elastocon s calibration manager Jonas Nilsson. Swedac s technical auditor examines Elastocon s calibration methods together with Niklas Vernholt, one of our field calibration specialists. The auditor from Swedac compile the report for the yearly control of our laboratory. Education of calibration on-site at a customers facility. Elastocon Mätcentrum is the part of Elastocon AB performing calibration Elastocon AB Tvinnargatan 25 SE-507 30 Brämhult, Sweden Phone: +46 33 22 56 30 info@elastocon.se www.elastocon.se