materials analysis Solutions for Your Analytical Business Markets and Applications Programs

Similar documents
Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Analysis of Cannabinoids and Amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source. Application.

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes Application

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

ENVIRONMENTAL analysis

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Test method for the determination of NDMA and NDEA by LC-MS/MS in Sartan containing film coated tablets

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Taking Full Advantage of UHPLC with Agilent 6460A Triple Quadrupole MS. Outline

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Accurate Mass Analysis of Hydraulic Fracturing Waters

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

MONITORING FOR PHARMACEUTICALS IN SURFACE WATER USING DIRECT AQUEOUS INJECTION ON THE AGILENT 6490 LC/QQQ

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

The Quantitation and Identification of Coccidiostats in Food by LC-MS/MS using the AB SCIEX 4000 Q TRAP System

Agilent ESI and APCI sources: for polar to non-polar compounds

Supporting Information

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Application Note. Abstract. Authors. Environmental

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Computer-assisted analysis of complex natural product extracts

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Application Note. Edgar Naegele. Abstract

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Application. Authors. Abstract. Introduction. Hydrocarbon Processing

LC-MS compatible Separation of the Fungicide Spiroxamine

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Quantitative Analysis and Identification of Migrants in Food Packaging Using LC-MS/MS

Anaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Highly sensitive quantitative estimation of genotoxic impurities from API and drug formulation using LC/MS/MS

High throughput analysis of polymer stabilizers with the Agilent 6420 Triple

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Ultrasensitive EPA Method 1694 with the Agilent 6460 LC/MS/MS with Jet Stream Technology for Pharmaceuticals and Personal Care Products in Water

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Application Note. Edgar Naegele. Abstract

Highly sensitive and rapid analysis of synthetic dyes in sea food by LC/MS/MS

Technical Note. Introduction

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

WADA Technical Document TD2003IDCR

SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

Food analysis. Solutions for Your Analytical Business Markets and Applications Programs

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS

Measuring Drug-to-Antibody Ratio (DAR) for Antibody-Drug Conjugates (ADCs) with UHPLC/Q-TOF

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Agilent LC & LC-MS Cannabis Testing

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS

Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Plasma-free Metanephrines Quantitation with Automated Online Sample Preparation and a Liquid Chromatography-Tandem Mass Spectrometry Method

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Separation of Large and Small Peptides by Supercritical Fluid Chromatography and Detection by Mass Spectrometry

Metabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria

Comprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods

Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

Guide to Peptide Quantitation. Agilent clinical research

Liquid Chromatography Mass Spectrometry. Shimadzu Corporation, UK; 2 Phytocontrol, France; 3 Shimadzu France, France. Trimesium S + CH 3 ETU

Transcription:

materials analysis DETERMINATION OF DIISOCYANATES IN PLASTICS USED IN TEXTILE PRODUCTS USING THE AGILENT 6410B LC/MS/MS Solutions for Your Analytical Business Markets and Applications Programs Author Dr. Dall Anese Riccardo Giovanni, Dr. Franchi Andrea and Dr. Giuseppe Bartolini Buzzi Laboratorio Analisi, Prato, Italy ABSTRACT Many textile products have surface coatings of plastic material that are used to give materials a particular aesthetic finish. Among the most widely used polymers are polyurethanes, which are generally obtained from monomers consisting of diisocyanates (eg. 2,4-TDI). The proposed analytical method enables a range of free diisocyanates to be easily determined using a simple derivatization procedure and analysed by LC/MS/MS INTRODUCTION The determination of specific diisocyanates is very important in ensuring the ecotoxicological safety of textile coated products to the final consumer. Regulation 1907/2006/CE sets a limit of 0.1% by weight (i.e. 1000 mg/kg) for MDI, although stricter limits are required by some private regulations, such as the OEKO-TEX Standard 100. The proposed analytical method follows the guidelines set out in UNI EN 13130-8:2005, but possesses substantial changes regarding timing and the method of derivatization. However, despite these changes that simplify the method, excellent sensitivity and low detection limits can be achieved.

ANALYTICAL TECHNIQUE Reagents Acetonitrile, formic acid, dibutylamine (CAS Number: 111-92-2), N,N -dimethylformamide (CAS Number: 68-12-2) and diisocyanates from Sigma-Aldrich (Milan, Italy). Instrumentation Chromatographic separation was performed on an Agilent 1200 HPLC system using an Agilent Zorbax Eclipse SB-C18 RRHT column and determined on an Agilent 6410B Triple Quadrupole Mass Spectrometer. Sample Preparation Samples are prepared using an ultrasonic extraction with dichloromethane and simultaneous derivatization with dibutylamine for 60 minutes. The resulting extract is then concentrated, resumes with 2 ml of N,N -dimethylformamide and made up to volume with mobile phase; the extracts are analysed by LC/MS/MS. This extraction procedure is faster and cheaper than UNI 13130-8 procedure. Operating Conditions LC Conditions Agilent 1200 HPLC System Analytical Column Agilent Zorbax Eclipse SB-C18 RRHT Column 2.1 x 50 mm, 1.8 µm Column Temperature 40ºC Injection Volume 2 µl Mobile Phase A= acetonitrile with 0.1% formic acid B= 0.05 mm formic acid Run Time 13 min, post run 6 min Flow Rate 0.25 ml/min Gradient Time (min) Gradient (% A) 0 60 0.5 60 10 100 13 100 MS Conditions Agilent 6410B Triple Quadrupole Acquisition Parameters ESI Positive Ion Mode Gas Temperature 320 ºC Gas Flow 10 L/min Nebulizer Pressure 50 psi Capillary Voltage 3000V 2

MRM Transitions The MRM transitions, fragmentor and collision energies for the compounds are shown below. Compound CAS Number Scan Segment Prosecursor Ion (m/z) Product Ion 1 (m/z) Product Ion 2 (m/z) Fragmentor Voltage (V) Collision Energy (V) 2,6-TDI 91-08-9 1 433 303 130 120 12 2-4-TDI 584-84-9 1 433 303 130 120 12 HDI 822-06-0 1 427 298 130 120 12 trans-ipdi 4098-71-9 2 481 352 130 120 12 4,4 -MDI 101-68-8 3 509 380 130 120 12 TMXDI 2778-42-9 3 503 157 130 120 12 cis-ipdi 4098-71-9 3 481 352 130 120 12 RESULTS AND DISCUSSION Calibration Curves Calibration was performed using a 7-point calibration. The calibration range and detection limits for each compound are listed in Table 1. Peak Compound Equation R2 Regression Range (μg/l) LOD (μg/ml) 1 2,6-TDI y=46001942.78x 0.9995 Linear, force by origin 1-1000 0.00049 2 2-4-TDI y=577870880.63x 0.9983 Linear, force by origin 1-1000 0.00078 3 HDI y=19309063.78x 0.9996 Linear, force by origin 1-1000 0.00056 4 trans-ipdi y=17761335.49x 0.9992 Linear, force by origin 0.5-500 0.00021 5 4,4 -MDI y=8305348.76x 0.9961 Linear, force by origin 1-1000 0.00071 6 TMXDI y=20555338.51x 0.9998 Linear, force by origin 1-1000 0.00043 7 cis-ipdi y=36184549.13x 0.9999 Linear, force by origin 0.5-500 0.00023 Table 1. Calibration information and limits of detection. 3

An example of a typical chromatogram is show in Figure 1. Calibration curves for cis-ipdi, 2,6-TDI and 2,4-TDI are shown in Figures 2, 3 and 4. Figure 1. Standard at 0.05 μg/ml showing elution sequence: (1) 2,6-TDI (2) 2,4-TDI (3) HDI (4) trans-ipdi (5) 4,4 - MDI (6) TMXDI (7) cis-ipdi Figure 2. Calibration curve for cis-ipdi. Figure 3. Calibration curve for 2,6-TDI. 4

Figure 4. Calibration curve for 2,4-TDI. CONCLUSIONS The proposed analytical method enables a range of diisocyanates to be determined. It is easily expandable to specific isocyanates which may be required in future and private regulations. The simplicity of the derivatization allows samples to be prepared safely, rapidly and economically whilst maintaining analytical sensitivity. REFERENCES [1] UNI EN 13130-8:2005: Materials and articles in contact with foodstuffs - Plastics substances subject to limitation - Part 8: Determination of isocyanates in plastics. [2] Daniel Karlsson, Jakob Dahlin, Åsa Marand, Gunnar Skarping, Marianne Dalene, Determination of airborne isocyanates as di-n-butylamine derivatives using liquid chromatography and tandem mass spectrometry, Analytica Chimica Acta, 534, 2005, 263 269. 5

Agilent Products are for Research Use Only. Not for use in diagnostic procedures. Information, descriptions and specifications in this publication are subject to change without notice. Solutions for your analytical business Markets & Applications Programs www.solutions-to-win.com Agilent Technologies, Inc. 2015 Published in USA, May 11, 2015 5991-5903EN