Kendrick mass = IUPAC mass x (14/ ) (1) Kendrick mass defect = nominal Kendrick mass exact Kendrick mass (2)

Similar documents
Optimizing of Volatile Organic Compound Determination by Static Headspace Sampling

Blood Alcohol Determination using Static Headspace Analysis with Optimized Sample Throughput

Analysis of Low Level Volatile Organic Compounds in Air Anne Jurek

Determination of Volatile Organic Compounds in Air

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Optimal Conditions for USEPA Method 8260B Analysis using the EST Analytical Sampling system and the Shimadzu GCMS-QP2010s

Optimizing Standard Preparation

A Single Calibration Method for Water AND Soil Samples Performing EPA Method 8260

Analysis of complex petrochemicals by GC GC TOF MS with Select-eV variable-energy electron ionisation

Maximizing Production While Minimizing Costs

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

The Truth About Dioxin Analysis: Using High Resolution GC-TOFMS and GCxGC-TOFMS to. Analytical Approaches

Methods of Analysis of Polychlorinated Biphenyl Congeners Using an Application-Specific Capillary GC Column

Identifying Disinfection Byproducts in Treated Water

U.S. EPA Method 8270 for multicomponent analyte determination

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

GC-APCI IMS of Diesel

Analysis of E.coli Tryptic Digest and Intact Protein Using the Agilent 1290 Infinity 2D-LC Solution with Diode Array Detection and Q-TOF LC/MS

Cerno Application Note Extending the Limits of Mass Spectrometry

Mass spectrometry prosess

Impurity Profiling of Pharmaceutical Starting Materials Using Gas Chromatography Coupled with High- Resolution Accurate Mass Spectrometry

GC Analysis of Polybrominated Flame Retardants Application

Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

CHEMISTRY Topic #3: Using Spectroscopy to Identify Molecules: Radicals and Mass Spectrometry (MS) Spring 2018 Dr.

JWH-018 and JWH-022 as Combustion Products of AM2201

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Determination of Hydrocarbon Components in Petroleum Naphthas

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

1-(1,3-benzodioxol-5-yl)-2-(ethylamino)hexan-1-one

MetWorks Metabolite Identification Software

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Characterization and Classification of Heroin from Illicit Drug Seizures Using the Agilent 7200 GC/Q-TOF

SPME-GC-MS/MS for Identification and Quantification of Migration Contaminants in Paperboard Food Packaging

Introduction to GC/MS

5Cl-AKB48 and 5Br-AKB48

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

N-(1-carbamoyl-2-methyl-propyl)-1-(5-chloropentyl)indazole-3- carboxamide

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Untargeted Identification of Organo-bromine Compounds in Lake Sediments by Ultra-

New Investigator Tools for Finding Unique and Common Components in Multiple Samples with Comprehensive Two-Dimensional Chromatography

WADA Technical Document TD2003IDCR

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Multi-residue analysis of pesticides by GC-HRMS

MS Interpretation I. Identification of the Molecular Ion

Drugs of Abuse by Direct Sample Probe Using Single Quadrupole GC/MS

Deposition and Detection System. Trace Level Analysis of Chemical Warfare Agents (CWAs) Related Chemicals by GC-IR Solid Phase System

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

2-[[2-(4-ethyl-2,5-dimethoxy-phenyl)ethylamino]methyl]phenol

Accurate Mass Analysis of Hydraulic Fracturing Waters

An ion source performs the following two functions:

Spectra Library Electron Capture Negative Ion (ECNI) Mass Spectra of Selected Polybrominated Diphenyl Ethers (PBDEs)

Discovering the Scent of Celery: HS-SPME, GC-TOFMS, and Retention Indices for the Characterization of Volatiles

4-methyl-1-phenyl-2-pyrrolidin-1-yl-pentan-1-one

Chapter 20. Mass Spectroscopy

PosterReprint INTRODUCTION

Methyl 1-[(4-fluorophenyl)methyl]indazole-3-carboxylate

Validation of GC-MS/MS for Detection and Confirmation of Low-Level Dioxins

AccuTOF GCx JMS-T200GC. Scientific / Metrology Instruments High Performance Gas Chromatograph Time-of-Flight Mass Spectrometer

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

4-Methyldiethcathinone (4-MDEC)

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Analysis of Extractable and Leachable (E&L) Compounds Using a Low-Energy EI-Capable High Resolution Accurate Mass GC/Q-TOF

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

Highly Sensitive and Rugged GC/MS/MS Tool

Author. Abstract. Introduction

NEW TOOLS FOR FINDING AND IDENTIFYING METABOLITES IN A METABOLOMICS WORKFLOW

Orbitrap GC-MS: An Opportunity to Help Address the Challenges of Chlorinated Paraffins Analysis

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

Mass Spectrometry. Ionizer Mass Analyzer Detector

Mass Spectrometry (MS)

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Benchtop NMR Combined with GC/MS Confirms Identity of Forensic Case Sample

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Gas chromatography/mass spectrometry (GC MS) Interpretation of EI spectra

UNIQUE SOLUTION FOR FLAVOUR AND FRAGRANCE IDENTIFICATION BY MEANS OF GC-MS (TOF) / CONDENSED PHASE FTIR

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

sample was a solution that was evaporated in the spectrometer (such as with ESI-MS) ions such as H +, Na +, K +, or NH 4

Date ACCURATE-MASS DATABASE FOR SCREENING OF PESTICIDE RESIDUES IN FRUITS AND VEGETABLES BY GAS CHROMATOGRAPHY TIME-OF-FLIGHT MASS SPECTROMETRY

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Supplementary Materials: Model-based peak alignment of metabolomic profiling from comprehensive two-dimensional gas chromatography mass spectrometry

ISO INTERNATIONAL STANDARD

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

C HA R AC T E RIZ AT IO N O F INK J E T P RINT E R C A RT RIDG E INK S USING A CHEMOMETRIC APPROACH

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Agilent G2350A Atomic Emission Detector (AED)

Determination of 59 potential Allergens in Perfumes by twin-line fast GCMSMS

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

A New Approach to the Analysis of Chlorinated Paraffins by Gas Chromatography Quadrupole Time of-flight Mass Spectrometry

Mass Spectrometry - Background

Automated and accurate component detection using reference mass spectra

Transcription:

JSB is an authorised partner of The use of Kendrick mass defect plots, a new feature in GC Image software for GCXGC/high h resolution mass spectrometric data analysis: an application on the t identification of o halogenated contaminants in electronic waste Masaaki Ubukata 1, Karl J. Jobst 2, Eric J. Reiner 2, Stephen Reichenbach 3, QingpingTao 4, Jiliang Hang 4, Zhanpin Wu 5, A. John Dane 1, and Robert B. Cody 1 1. OL USA, Inc., Peabody, MA USA, 2. Ontario Ministry of the Environment, Toronto, Canada, 3. University of Nebraska-Lincoln, Lincoln, NE USA, 4. GC Image LLC, Lincoln, NE USA, 5. Zoex Corporation, Houston, TX USA Introduction The combination of GC x GC with high resolution mass spectrometry (HRMS) is a powerful tool for the analysis of complex mixtures. Hundreds/thousands of components can be separated and detected. However, interpreting the data sets generated by a GC x GC/high resolution time-of-flight mass spectrometry system can be challenging due to the unprecedented amount of information the data offers. In 1963, Edward Kendrick realized that by converting the International Union of Pure and Applied Chemistry (IUPAC) mass scale (C = 12.000 Da) to one in which CH 2 = 14.000 Da (equation 1), organic ions belonging to a homologous series have identical Kendrick mass defect (equation 2). An example of Kendrick mass and Kendrick mass defect for methyl, ethyl, and propyl naphthalene is listed in Table 1. This approach greatly simplifies the high resolution mass spectrometric data analysis [1]. Kendrick mass = IUPAC mass x (14/14.01565) (1) Kendrick mass defect = nominal Kendrick mass exact Kendrick mass (2) Table 1. Kendrick Mass Defect for Naphthalenes Compound Kendrick Mass Kendrick Mass Defect Methyl naphthalene (C 11H 10) 141.9195 0.0805 Ethyl naphthalene (C 12H 12) 155.9195 0.0805 Propyl naphthalene (C 13H 14) 169.9195 0.0805 In this study, nontraditional Kendrick mass defect by the substitution of a hydrogen with a chlorine atom was used to facilitate the identification of halogenated components in an electronic waste sample [2]. The capability of constructing Kendrick mass defect plots has been implemented into GC Image software version 2.5. I N S P I R A T I O N M E E T S I N N O V A T I O N!

Method Sample analysis A dust sample collected from an electronic recycling facility was analyzed by using GC x GC (Zoex ZX2 thermal modulator) in combination with a new high-resolution time-of-flight (TOF) mass spectrometer (JEOL AccuTOF GCv 4G). The instrument parameters are listed in Table 2. Table 2. Instrument Parameters Conditions GC x GC/EI Sample Dust collected from an electronic recycling facility GC x GC system Zoex ZX2 thermal modulator 1st column Rxi-5SilMS, 30 m x 0.25 mm, 0.25 μm 2nd column Rxi-17SilMS, 2 m x 0.15 mm, 0.15 μm Modulation loop Deactivated fused silica, 1.5 m x 0.15 mm Modulation period 8 s Modulation duration 400 ms Inlet mode Splitless, constant flow Oven temp. 50 C (1 min) -> 5 C/min -> 320 C (5 min) GC-TOFMS system AccuTOF GCv 4G (JEOL) Ionization mode EI+, 70 ev Ionization current 300 μa Ion source temp. 250 C MS transfer line temp. 280 C m/z range m/z 45-800 Acquisition time 20 ms (50 Hz) Software GC Image Version 2.5 Mass calibration A single point external mass calibration with one column bleed ion C 5H 15O 3Si 3+, m/z 207.0329 was performed after data acquisition. Kendrick mass defect plot An average mass spectrum for the entire retention time region was created by summing the mass spectra for all data points in a GC x GC/HRMS data set. Nontraditional Kendrick mass defect (H/Cl mass defect) was calculated. Kendrick mass defect plot was constructed with the nominal mass vs. the corresponding mass defect for each peak in the average mass spectrum.

Results and Discussion Figure 1 shows the GC x GC total ion chromatogram for an electronic waste sample. An average mass spectrum for the entire retention time region was generated and showed in Figure 2. The exact mass for each ion was converted to H/Cl mass (equation 3) and an H/Cl mass defect plot for the average mass Fig. 1 GC x GC TIC chromatogram of a dust sample spectrum was constructed and showed in Figure 3 automatically with GC Image software version 2.5. H/Cl mass = IUPAC mass x (34/33.96102) (3) Figure 3 shows that ions in each class of halogenated compounds differing by H/Cl substitution align with the horizontal axis since they have the same H/Cl mass defect. Those compounds can be easily, immediately recognized visually in the H/Cl mass defect plot. This greatly simplified halogenated compounds identification in a complex GC x GC chromatogram. By drawing a polygon around each class of halogenated compounds, mass chromatograms can be generated automatically. Figure 4 shows the high resolution GC x GC mass chromatograms for the most abundant Fig.2 Average mass spectrum for the entire retention time region

Fig. 3 H/Cl mass defect plot for the average mass spectrum isotope ions for each class of halogenated compounds. The NIST library search and exact mass measurement were used to confirm the identification. The exact mass measurement results are listed in Table 4. Fig. 4 GC x GC mass chromatograms for the most abundant isotope ions ± 50 ppm (a) TCPP, (b) polychlorinated terphenyl, (c) tetrabromobisphenol A, (d) PCBs, (e) PBDEs, and (f) hexabromobenzene

Compound Table 4. Exact mass measurement results Elemental Theoretical Measured Composition Mass Mass Difference (mmu) TCPP C 8H 13Cl 5O 4P + 380.895910 380.896356-0.446 Terphenyls Cl 8 C18H6Cl 8 505.791323 505.791346-0.023 Cl9 + C18H5Cl 9 539.752351 539.752675-0.324 Cl10 C 18H 4Cl + 10 573.713378 573.714726-1.348 Cl11 C 18H 3Cl + 11 607.674406 607.675086-0.68 Tetrabromobisphenol A C 14H 9Br 4O + 2 528.728964 528.728857 0.107 PCBs Cl4 C 12H 6Cl + 4 291.918862 291.918259 0.603 Cl5 C 12H 5Cl + 5 325.879890 325.879644 0.246 Cl6 C 12H 4Cl + 6 359.840918 359.840915 0.003 Cl7 C 12H 3Cl + 7 393.801945 393.802354-0.409 Cl8 C 12H 2Cl + 8 429.760023 429.760063-0.04 PBDEs Br2 C 12H 8Br 2O + 327.891595 327.891217 0.378 Br3 C 12H 7Br 3O + 405.802108 405.801461 0.647 Br4 C 12H 6Br 4O + 485.710574 485.709147 1.427 Br5 C 12H 5Br 5O + 563.621087 563.620149 0.938 Br6 C 12H 4Br 6O + 643.529553 643.529852-0.299 Br7 + C12H3Br7O 721.440066 721.439888 0.178 Hexabromobenzene C 6Br + 6 551.503338 551.502866 0.472 Conclusion The combination of GC x GC with high resolution time-of-flight mass spectrometry is a powerful tool for analysis of complex mixtures. The halogenated compounds can be easily, immediately, and visually distinguished in a very complicated GC x GC chromatogram by using H/Cl mass defect plots a new feature in GC Image software version 2.5. The identification is further confirmed by NIST library search and the exact mass measurement results. References [1] Edward Kendrick, A mass scale based on CH2 = 14.000 for high resolution mass spectrometry of organic compounds, Anal. Chem (1963) 35:2146 2154 [2] Karl J. Jobst, Li Shen, Eric J. Reiner, Vince Y. Taguchi, Paul A. Helm, Robert McCrindle, Sean Backus, The use of mass defect plots for the identification of (novel) halogenated contaminants in the environment, Anal Bioanal Chem (2013) 405:3289 3297 INTERNATIONAL JSB Group Tramstraat 15 5611 CM Eindhoven T +31 (0) 40 251 47 53 F +31 (0) 40 251 47 58 INFO@GO-JSB.COM WWW.GO-JSB.COM SALES AND SERVICE NETHERLANDS Apolloweg 2B 8239 DA Lelystad T +31 (0) 32 087 00 18 F +31 (0) 32 087 00 19 GERMANY, AUSTRIA, SWITZERLAND Max-Planck-Strasse 4 D-47475 Kamp-Lintfort T +49 (0) 28 42 9280 799 F +49 (0) 28 42 9732 638 BELGIUM Grensstraat 7, Box 3 1831 Diegem T +32 (0) 27219211 F +32 (0) 27207622 UK & IRELAND Cedar Court, Grove Park Business Est. White Waltham, Maidenhead, Berks, SL6 3LW T +44 (0) 16 288 220 48 F +44 (0) 70 394 006 78