MEMBREX. Ready-to-use Syringe Filters < 1 up to 100 ml. Minimizes Loss of Sample. Minimale Holdup-Volume. Low Adsorption.

Similar documents
GL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI

Thermo Scientific Titan3 and Target2 Chromatography Syringe Filters. Performance filtration solutions. for sample preparation

HPLC Sample Preparation

High Performance Liquid Chromatography

High Performance Liquid Chromatography

N) manual. Biomaster Operating manual

N6,6 Posidyne Membranes

ProPac WCX-10 Columns

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

ab Carrez Clarification Reagent Kit

Cellufine Butyl Cellufine Phenyl

Shodex TM ODP2 HP series columns

ept.i.p.s. pipette tips are available with various degrees of purity, with and without filters, and as special tips.

Sepax SRT -C, Zenix -C SEC Phases

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Technical data and operating instructions. Vivaspin 4. Vivaspin 4 10K device for in vitro diagnostic use

High Performance Liquid Chromatography

OMX-S basic Kit Instruction Manual March/09

Determination of Polymer Modifier in Asphalt

Guide to Choosing and Using Polymer Reversed Phase Columns!

ION CHROMATOGRAPHY SYSTEM S 150

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

ept.i.p.s. Instructions for use Version B


Protein separation and characterization

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Nickel-Plated Brass Push-In Fittings - NPTF/INCH

Laboratory filtration. Principles and chemical compatibility chart

ph electrodes with screw cap S7. Special application electrodes.

Open Column Chromatography, GC, TLC, and HPLC

Biofuels Series. Application Note 301LS RAPID MEASUREMENT OF XYLOSE AND GLUCOSE MONITORING CORN STOVER FERMENTATION IN BIOETHANOL PRODUCTION

Cellufine Butyl Cellufine Phenyl

1 Product description. Material. 3 Warnings for intended use. Instructions for use ept.i.p.s. Version B. English (EN)

High Performance Liquid Chromatography

Homogenisation with Perfection

For purification/separation of organic and aqueous phases from a two phase mixture within a 96 or 24 array tube system

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

Technology offer: Environmentally friendly holographic recording material

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

What is Flow Reactor. High efficiency reaction using Microreactor. Reaction example. Flow Reactor. What s Flow Reactor.

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

HPLC Columns. HILICpak VT-50 2D MANUAL. Shodex HPLC Columns Europe, Middle East, Africa, Russia

Sample preparation for X-ray fluorescence analysis VII. Liquid sample

Diquat 1,1 -ethylene-2,2 -bipyridium dibromide salt Paraquat 1,1 -dimethyl-4,4 -bipyridium dichloride salt Initial Preparation

Chemistry Instrumental Analysis Lecture 31. Chem 4631

Gluten (Gliadin) Lateral Flow IIR

Polymer analysis by GPC-SEC. Technical Note. Introduction

Low-adsorbing track-etched membrane

Moisture holding capacity 61 to 69 % Shipping Weight Specific gravity 1.06 to 1.08 Particle size

C18 Column. Care & Use Sheet

symphony Reference Electrodes


Glossary of Common Laboratory Terms

ACETONE IN URINE BY UV CODE Z42010

The use of bubble point test in membrane characterisation

HICHROM. Chromatography Columns and Supplies. SAMPLE PREPARATION Solid Phase Extraction - CHROMABOND. Catalogue 9. Hichrom Limited

Multi-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for Sample Preparation

user manual blotting Hoefer PR648 Slot blot manifold um PR648-IM/Rev.F0/08-12

for Acclaim Mixed-Mode HILIC-1 Column

What type of samples are common? Time spent on different operations during LC analyses. Number of samples? Aims. Sources of error. Sample preparation

Please use only the valid version of the package insert provided with the kit. This kit is intended for Research Use Only.

Chromatography. Intro basic terminology types Partition and Adsorption C Ion-Exchange C Gel Filtration (aka Exclusion or Molecular Sieve) C Affinity C

Even wall thickness to with stand maximum G force.

07/03/18. Laboratory Water and Water Purification Systems. Water in the Laboratory. Sources of Water and Water Contamination. Contaminants in Water

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

WHAT YOU NEED TO KNOW:

4023 Synthesis of cyclopentanone-2-carboxylic acid ethyl ester from adipic acid diethyl ester

Gas Chromatography. Vaporization of sample Gas-solid Physical absorption Gas-liquid Liquid immobilized on inert solid

Columns and supplies catalog

MODULE 4.3 Atmospheric analysis of particulates

BIOO FOOD AND FEED SAFETY. Histamine Enzymatic Assay Kit Manual. Catalog #: Reference #:

stance et Helper Eppendorf Pipet Helper Chemical Resistance

2. WATER : THE SOLVENT FOR BIOCHEMICAL REACTIONS

Enantioselective Transamination in Continuous Flow Mode with Transaminase Immobilized in a Macrocellular Silica Monolith. Supporting Information

Week 10 Chemical Synthesis

Sulfotepp impurities in Chlorpyrifos EC formulations

Automatic titrators, TitroMatic

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies

LC Technical Information

Dynasylan SIVO 110. Description. Product Information. SIVO SOL Technology for coating systems

Chapter content. Reference

Appendices towards the Operation Manual of Ultrasonic milk analyzer Lactoscan

Chemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder

Monkey Kidney injury molecule 1,Kim-1 ELISA Kit

HPLC Background Chem 250 F 2008 Page 1 of 24

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

CHROMATOGRAPHY. The term "chromatography" is derived from the original use of this method for separating yellow and green plant pigments.

Revised 24 Nov rm (Vers. 15.1)

Sample Preparation TLC Plates

Now also in Eppendorf LoBind. Conical Competence. Eppendorf Conical Tubes 15 ml and 50 ml

HPLC analysis of VFAs, Furfural and HMF

Xanthine Oxidase Assay Kit

NukEx Nucleic Acid Release Reagent

Biochemistry. Biochemical Techniques HPLC

Tubing cassettes. Developed and consistently improved by ISMATEC IDEX ISMATEC. Option. Click'n'go cassette with

NORBUPRENORPHINE (Buprenorphine s Metabolite ) BUPRENORPHINE in urine by GC/MS Code GC Method of Confirmation by GC-MS

Introduction to Work in Laboratory

Transcription:

MEMBREX < Ready-to-use Syringe Filters < 1 up to 100 ml Minimizes Loss of Sample Minimale Holdup-Volume Low Adsorption Optimized Shape

MEMBREX Syringe filters Offering syringe filters in various shapes combined with different membranes allows the user to choose an optimal filter unit to filter 1 ml up to 1.5 l. The design of the filter results in a 15 % increase in filter area. The housing is made of Polypropylene which is compatible with most commonly used solvents. Connecters to the syringe are Luer Lock female. Others on request. Choosing the smallest size you minimize loss of sample, waist and costs! MEMBREX 4 The smallest one can be used for filtration of < 1 ml, available with membranes of CA, PTFE and Nylon in 0.2 und 0.45 µm poresize. MEMBREX 4, and Filtration Volume Holdup-Volume Diameter < 1 ml < 5 µl 4 mm ml µl mm ml µl mm MEMBREX PTFE The hydrophobic membrane made of Polytetrafluorethylene allows air to pass and retains water. These MEMBREX are used for vent applications and as a contamination protection. The broad compatibility allows filtration even of aggressive organic solvents. MEMBREX 50 The largest filter allows filtration up to 5 l, available with a CA-membrane used for aqueous solutions or a hydrophobic PTFE membrane. These MEMBREX are used for ventilation applications and as a contamination protection. Some users integrate it in the tube of a vacuum pump to protect it from aqueous contaminations. The broad compatibility allows filtration even of aggressive organic solvents. Connectors are hose barb.

Safety and Pressure Stability Do not exceed the pressure, temperature or chemical compatibility recommendations. High pressures can be obtained when using syringes. The smaller the syringe, the higher the pressure that can be generated. As a general guide, the following pressures can be obtained by hand with the syringes indicated: 20ml - 30 psi 10ml - 50 psi 5ml - 75 psi 3ml - 100 psi 1ml - 150 psi. 14,5038 psi = 1 bar 1 psi = 0.068947 bar Each user should determine the pressure they can generate by hand with a specific size syringe and take appropriate safety precautions not to exceed the recommended rating for the device used. If these limitations are exceeded, bursting of the device may occur, resulting in loss of property or personal injury. We are just in a process of changing our syringe filters from housings that are tested as a minimum with 5 bar to a different shape that is more stable against pressure. Our new filters are tested with a minimum effective burst pressure of > 14 kg/cm² (1 bar = 1.02 kg/cm²). MEMBREX CA with Cellulose Acetate Membrane Low binding Hydrophilic Strength and dimension stability Uniform pore structure and size MEMBREX CA Often used for sterilization or clarification of even the most viscous proteinaceous solutions. Applications Sterilization or filtration of biological fluids, serum or media additives, Sample preparation of protein-based HPLC solutions, High throughput, low binding filter units for nonsterile aqueous filtrations, Filter probe and hybridization solutions to reduce backgrounds, Protein and enzyme filtration, sterilization

MEMBREX Nylon Available with the new housing that is pressure stable. MEMBREX designed for filtration with higher pressure up to 10 bar (140 psi), minimum effective burst presssure.7 bar. Lot release criteria include tests concerning Integrity, Flow rate performance, burst pressure, HPLC testing and leakage. The plastics passed USP Class VI biosafety tests. Applications Perfect for filtering aqueous or organic HPLC samples, buffer and serum Low extractables No wetting agents Higher dirt handling capacity compared to Polyester Properties of Nylon Nylon membrane is hydrophilic and is a good choice for aqueous and/or organic samples. The membrane offers good chemical resistance to most common HPLC solvents; however, it has limited resistance to acids, bases, halogenated hydrocarbons, aldehydes and strong oxidising agents. The most common application is HPLC sample filtration. Not recommended when low protein binding is important - adsorption of protein >100 µg/cm²

MEMBREX PET with Polyester-Membrane Good choice to use for filtration of samples for HPLC, GC, CE, IC and TOC-Analytics No extractables in the membrane no impurities Low non specific binding MEMBREX PET There is no need any longer to use different filters for aqueous and nonpolar samples. In the past confounding the filters caused a lot of trouble. High range of chemical compatibility, resistant to a wide range of chemicals. It is comparable to teflon that is usually much more expensive. Another advantage the membrane it is hydrophilic without any wetting treatments. There are no extractables because the membrane is produced without any surfacespecific substances. In the first step, thin polyester film is exposed to collimated, charged particles from a nuclear pile. As these particles pass through the polyester material, they leave sensitized tracks. In the second step, the polymer tracks are dissolved with an etching solution to form cylindrical pores. Varying the temperature and strength of the etching solution, and the exposure time to it, produces precisely controlled pore sizes. It is only 10 µm thin, with a smooth, glass-like surface. Low protein binding of < 5 µg/cm² prohibits absorption of cells being filtered. Negligible absorption/adsorption, maximizes critical solution recovery. POLYESTER or Nylon To choose Nylon or Polyester depends on the application. If removal of dirt is important - Nylon is the best choice, if low protein binding is needed we recommend Polyester.

MEMBREX PTFE Polytetraflouroethylene supported with polypropylene Membrane is stretched biaxially to form the porous structure. PTFE-membranes are naturally hydrophobic. A pretreatment with alcohol is possible to allow filtration of aquaeous solvents. Hydrophobic PTFE-membrane Tortuous pore structure laminated to a polypropylene backing for improved strength. Best choice for air venting and gas filtration. Often used in pipettes to protect them from contamination. Available for Pipetteboy, Pipettus and Sarstedt. Superior chemical resistance clarification and sterilization filtration of chemically aggressive liquids such as solvents, acids and strong bases. Can be used at temperatures of up to 100 o C. Attention : Autoclaving can destroy the binding between support and PTFE. We introduced the MEMBREX now that we sell as standard items. On request we can deliver MEMBREX with every membrane you need. Please check the following requirements: We need an order for at least 10 000 units. Housings of the MEMBREX are the same than in the standard version 4, or mm diameter.

Applications Membrane Type Diameter (mm) Filtration Volume (ml) Holdup Volume (µl) Sterile Filtration aqueous additives for cellculture Cellulose Acetate (CA) 4 50 < 1 < 5000 < 5 0 Sterile Filtration minimum adsorption of protein Polyester (PET) Sample preparation aqueous and organic Polyester (PET) low nonspecific adsorption for HPLC, IC, GC and CE Nylon high dirt handling capacity 4 < 1 < 5 Sample preparation organic Teflon hydrophobic (PTFE) for aggressive solvents 4 50 < 1 > 5000 < 5 0 Ventilation prevents contamination Teflon hydrophobic (PTFE) 50 airstream in ml/min at 0.7 bar and 0.45 µm pore size 34 150