LIQUID XE DETECTOR FOR MU E GAMMA SEARCH

Similar documents
Kenji Ozone (ICEPP, Univ. of Tokyo, Japan) Outline. Introduction prototype R&D ー PMTs ー small & large type summary

Status and Future of the PSI Experiment *

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Liquid xenon gamma-ray calorimeter for the MEG experiment

Lepton Flavour Violation

LXe (part B) Giovanni Signorelli. Istituto Nazionale di Fisica Nucleare, Dipartimento di Fisica and Scuola Normale Superiore, Pisa (Italy)

arxiv: v1 [physics.ins-det] 1 Sep 2009

arxiv:physics/ v1 3 Aug 2006

arxiv:astro-ph/ v1 15 Feb 2005

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory

Distillation purification and radon assay of liquid xenon

The MEG/MEGII and Mu3e experiments at PSI. Angela Papa Paul Scherrer Institut on behalf of the MEG/MEGII and Mu3e collaborations

MEG. 2.1 KEK PSI PSI MEG II [4] GeV 2. Tevatron [5] 2017 ( 29 ) 12 12

Drift plane. substrate (20ÉIm polyimide) 200ÉIm. Back strip (180ÉIm width) Base (Ceramic) Anode strip (10ÉIm width) Cathode strip (100ÉIm width)

XMASS 1.5, the next step of the XMASS experiment

(a) Mono-absorber. (b) 4-segmented absorbers. (c) 64-segmented absorbers

A Trial of Neutrino Detection from Joyo Fast Research Reactor

The MEG experiment at PSI

clfv searches using DC muon beam at PSI

Lepton Flavor Violating Decays Review & Outlook

Appendix A2. Particle Accelerators and Detectors The Large Hadron Collider (LHC) in Geneva, Switzerland on the Border of France.

PoS(ICHEP2016)552. The Mu3e Experiment at PSI. Alessandro Bravar University of Geneva

Count. Count. 200mm. PMT scintillation. PMT flourescence. PMT fluorescence. PMT fluorescence. PMT fluorescence. 50mm. 42mm

THE qualities of liquid xenon (LXe) as an efficient

Performance of the MCP-PMT for the Belle II TOP counter

Highlights from the 9 th Pisa Meeting on Advanced Detectors Calorimetry Session

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

The Dual-Phase Liquid Xenon Time Projection Chamber (TPC) of Münster

PoS(PhotoDet 2012)010

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

DETECTORS. I. Charged Particle Detectors

Direct WIMP Detection in Double-Phase Xenon TPCs

ZICOS - New project for neutrinoless double beta decay experiment using zirconium complex in liquid scintillator -

Experimental Searches for Muon to Electron Conversion

Results and perspectives of the MEG and MEG II experiments

A measurement of the air fluorescence yield

LFV with µ-beams: status and perspectives

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

Measurement of the transverse diffusion coefficient of charge in liquid xenon

arxiv: v1 [physics.ins-det] 23 Oct 2007

A novel design of the MeV gamma-ray imaging detector with Micro-TPC

arxiv:physics/ v1 [physics.ins-det] 14 Feb 2005

Since the beam from the JNC linac is a very high current, low energy beam, energy loss induced in the material irradiated by the beam becomes very lar

The Search for Dark Matter with the XENON Experiment

Recent results at the -meson region from the CMD-3 detector at the VEPP-2000 collider

Fundamental Symmetries III Muons. R. Tribble Texas A&M University

EEE4106Z Radiation Interactions & Detection

PHYS 3446 Lecture #12

Absorption of Scintillation Light in a 100 l Liquid Xenon γ Ray Detector and Expected Detector Performance

The PIENU Experiment a sensitive probe in the search for new physics

Detection and measurement of gamma-radiation by gammaspectroscopy

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

The ortho-positronium lifetime puzzle & new Physics

PoS(PD07)020. Timing Properties of MCP-PMT. Kenji Inami. Nagoya university, Nagoya, Japan

PoS(TIPP2014)093. Performance study of the TOP counter with the 2 GeV/c positron beam at LEPS. K. Matsuoka, For the Belle II PID group

Measurement of the e + e - π 0 γ cross section at SND

anti-compton BGO detector

THE COMPTON EFFECT Last Revised: January 5, 2007

MEG II 実験の準備状況と 今後の展望 東京大学 素粒子物理国際研究センター 岩本敏幸 他MEG II コラボレーション 2018年9月14日 日本物理学会2018年秋季大会 信州大学 JSPS Core-to-Core Program

Quality Assurance. Purity control. Polycrystalline Ingots

X-ray ionization yields and energy spectra in liquid argon

Scintillation Detectors

Scintillation Detectors

arxiv: v2 [physics.ins-det] 17 Jun 2014

Overview of the COMET Phase-I experiment

arxiv: v1 [physics.ins-det] 3 Feb 2011

AIRFLY: Measurement of the Air Fluorescence induced by electrons

Hands on Project: Large Photocathode PMT Characterization

arxiv: v1 [physics.ins-det] 26 Sep 2018

Neutrino Physics. Neutron Detector in the Aberdeen Tunnel Underground Laboratory. The Daya Bay Experiment. Significance of θ 13

PoS(FPCP2017)024. The Hyper-Kamiokande Project. Justyna Lagoda

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

The relevance of XENON10 constraints in this low-mass region has been questioned [15] C.E. Aalseth et al. arxiv: v1

Studies of the XENON100 Electromagnetic Background

Error Budget in π + e + ν Experiment

Measurements of liquid xenon s response to low-energy particle interactions

PANDA-?? A New Detector for Dark Matter Search

The First Large Application of MPPC: T2K Neutrino Beam Monitor INGRID

Hands on LUNA: Detector Simulations with Geant4

Characterizations and Diagnostics of Compton Light Source

arxiv: v1 [physics.ins-det] 27 Jun 2017

arxiv: v2 [physics.ins-det] 28 Jul 2010

Introduction Polarimeters at MAMI Analysis Future Conclusion. Polarimetry at MAMI. V. Tyukin, Inst. of Nuclear Physics, Mainz, Germany

Test bench for measurements of NOvA scintillator properties at JINR D.S. Velikanova, 1 A.I. Antoshkin, 1 N.V. Anfimov, 1 O.B.

LAAPD Performance Measurements in Liquid Xenon

Measurement of Positronium hyperfine splitting with quantum oscillation

DEVELOPMENT OF ADVANCED NEUTRON INDUCED PROMPT GAMMA- RAY ANALYSIS SYSTEM FOR SURVEY OF ANTI-PERSONNEL MINES

Temperature Dependence Calibration and Correction of the DAMPE BGO Electromagnetic Calorimeter

Monte Carlo Simulations for Future Geoneutrino Detectors

Scintillation Detector

Improving neutron detection efficiency by using passive converters

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

The XENON100 Dark Matter Experiment at LNGS: Status and Sensitivity

Dark Matter Searches with AMS-02. AMS: Alpha Magnetic Spectrometer

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

COMET muon conversion experiment in J-PARC

arxiv: v1 [physics.ins-det] 11 Mar 2010

Correction for PMT temperature dependence of the LHCf calorimeters

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Transcription:

LIQUID XE DETECTOR FOR MU E GAMMA SEARCH K. OZONE representing MUEGAMMA collaboration University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, JAPAN E-mail: ozone@icepp.s.u-tokyo.ac.jp A new type of liquid Xe detector has been developed for an experiment searching for µ + e + γ at Paul Scherrer Institute(PSI). The detector utilizes liquid xenon as a scintillation material. The scintillation light are observed by photomultiplier tubes(pmts) immersed in liquid xenon. The performance of the detector has been investigated with two prototypes. The first prototype with an active volume of 2.3 liter viewed by 32 PMTs was tested by using radioactive γ-ray sources of 0.3 MeV to 1.8 MeV. From the first prototype results, it is expected that 1 %(r.m.s.) for energy resolution for 52.8-MeV γ, a few mm for position, and 50 psec for time will be obtained. The second larger prototype has already constructed, which has an active volume of 68.6 liter viewed by 228 PMTs. The second prototype is now undergoing all the necessary tests for construction of a final detector using Compton backscattered γ-rays up to 40 MeV. 1 Introduction Fundamental theories such as SUSY-GUT seem to generically predict that µ eγ occurs with a decay branching ratio somewhere above 10 14 [1, 2]. The latest upper limit of the branching ratio for µ eγ decay is 1.2 10 11 at the 90% confidence level measured by the MEGA collaboration at LAMPF [3]. A new µ eγ experiment is planned at Paul Sherrer Institute (PSI) in Switzerland and detector development is undergoing, aiming to improve the sensitivity by 3 orders of magnitude compared with current world limit [4]. The experimental setup consists of a liquid Xe photon detector and a positron spectrometer with a superconducting solenoid magnet [5], as shown in Fig. 1. In this experiment, surface µ + beam with an intensity of 10 8 /s is stopped in a target located at the center of the spectrometer. If the µ + e + γ decay occurs, a back-to-back e + and γ will be observed with respective energy of 52.8 MeV in time. In the µ eγ search there are two major backgrounds. One is the radiative muon decay of µ e ν e ν µ γ. It looks like the µ eγ signal when the two neutrinos take away with small amount of momenta. The other is an accidental overlap of positrons around the energy edge of the Michel decay and unexpected γ(s) such as from annihilation in flight. The liquid Xe detector is the key to suppress such big amount of backgrounds, and ozone: submitted to World Scientific on February 15, 2005 1

we are now researching and developing it. Liq. Xe Scintillation Detector Liq. Xe Scintillation Detector Muon Beam γ Thin Superconducting Coil Stopping Target γ Drift Chamber + e Timing Counter + e Drift Chamber 1m Figure 1. A schematic view of the µ eγ detector along the beam axis(left) and perpendicular to beam axis(right). 2 Liquid Xe Detector Liquid xenon has several advantages as a scintillator material. It has large light yield (W ph = 24 ev [6]), and its scintillation pulse has a fast response and short decay time which minimizes pile-ups under such high rate condition. Additionally it is free from a problem of non-uniformity which crystal scintillation detectors ought to have. A schematic view of the liquid Xe detector for the µ eγ search is shown in Fig. 2. Similar to the Kamiokande detector, liquid xenon volume is surrounded with arrays of about 800 PMTs [7] for detecting scintillation light emitted inside. The PMT was specially developed for this experiment in cooperation with Hamamatsu Photonics K. K, so that all the PMTs can be immersed in liquid xenon. Properties of the PMT are summarized in Table 1. In order to study performance of the detector for 52.8-MeV γ, two kinds of prototypes has been constructed and their performance has been tested. One is a small prototype and studies with this detector were successfully completed. The other is a large prototype and studies on it are now in advance. ozone: submitted to World Scientific on February 15, 2005 2

MEG Refrigerator H.V. Signals Cooling pipe Vacuum for thermal insulation Liq. Xe Al Honeycomb window PMT Plastic filler 0 50 100 cm Figure 2. Cross sectional view of liquid Xe detector for µ eγ search. Table 1. Properties of the PMT for the liquid Xe detector(in liquid xenon). PMT size 57 mm φ Photo-Cathode material Rb-Cs-Sb Size of effective area 46 mm φ Typical Q.E. 5 % Dynode Type Metal channel Number of stages 12 Typical H.V. 900 V Typical gain 3 10 6 3 Small Prototype The first prototype has an active volume of 116 116 174 mm 3 (2.3 liter) viewed by 32 PMTs as shown in Fig. 3(left). The PMTs were placed inside double-layer vessels for thermal insulation as illustrated in Fig. 3(right). Liquid nitrogen was used for liquefaction of xenon. It took 12 hours to fill the ozone: submitted to World Scientific on February 15, 2005 3

vessel with sufficient liquid xenon. After completing the liquefaction, the flow of liquid nitrogen in copper cooling pipe was controlled to keep liquid xenon stable. LEDs were equipped on the corners of the holder for calibration of the PMT outputs. An α souce 241 Am was attached on one side for monitoring stability of PMTs because it can be regarded as point-like light source in liquid xenon. The PMT output was stabilized within an accuracy of 0.5% in 5 hours after liquefaction as described in [4]. One of γ-ray sources ( 51 Cr, 137 Cs, 54 Mn, 88 Y) ranging from 0.3 MeV to 1.8 MeV were placed on the other side to study the energy, position, and timing resolution. Weighted mean with their individual number of observed photoelectrons was used for evaluating the interaction point. All the resolutions were calculated after requiring that the interaction point should lie in a central volume ( 1 cm< x, y, z < 1 cm) of the detector. All the results were compared with the predictions from Monte Carlo simulation which incorporated with EGS4 [8]. The same analysis was applied for the experimental data and the simulated data. Gamma ray source HAMAMATSU R6041Q Alpha source vacuum for thermal insuration Liquid Nitrogen Cooling Pipe Gas Xe ~1 atm Gas Xe Liquid Xe ~ 160 K LEDs on corners Y z x Active volume 3 11.6x11.6x17.4cm Figure 3. Experimental setup of the small prototype and its cooling vessel. 3.1 Energy resolution The energy resolution was evaluated after selecting events with the estimated interaction point described above. Energy spectra for each of γ-ray source ozone: submitted to World Scientific on February 15, 2005 4

were fitted with asymmetric Gaussian functions. The right part of the Gaussian peak included the fully-contained events while the left part was affected by energy leakage. This is why the sigma of the right part represented the energy resolution. Fig. 4(a) shows the summary of energy resolutions. It is also found that the prediction by the simulation (dashed line) is in good agreement with the experimental data. For evaluating the liquid Xe detector performance for 52.8-MeV γ, these results are extrapolated to higher energy. It is suggested that about 1% resolution in sigma will be obtained at 52.8 MeV. 3.2 Position resolution The position resolution was estimated in the following way. Firstly, the 32 PMTs were divided into two groups at the middle height (x-z plane) of the detector, and then interaction points were evaluated in each of the groups. From the distribution of the difference between them, the position resolution could be evaluated. Energy Resolution (%) 20 18 16 14 12 10 8 (a) 51 Cr 137 Cs Position Resolution (mm) 10 9 8 7 6 5 4 (b) 51 Cr 137 Cs 54 Mn 6 54 Mn 88 Y 3 88 Y 4 2 2 1 0 0-1 10 10-1 1 Energy (MeV) 1 Energy (MeV) Figure 4. Energy(a) and position(b) resolutions with the small prototype, as compared to the predictions (dashed lines) by the simulation. The results are summarized in Fig. 4(b) together with the prediction by ozone: submitted to World Scientific on February 15, 2005 5

the simulation. It indicates that the position resolution tends to improve as a function of 1/ E, where E represents energy of γ-ray sources. As for position resolution, simple extrapolation is not always adequate and more systematics should be taken into account. However, we can safely conclude that the resolution for 52.8-MeV γ will be a few mm. 3.3 Timing resolution In the similar way as done for evaluating the position resolution, the timing resolution was calculated. The 32 PMTs were divided into two groups again and mean of arrival time in each group was calculated after ADC slewing correction for each of the PMTs with a qualification that the number of observed photoelectrons is over 100. The obtained timing resolution is summarized in Fig. 5 as a function of the total number of observed photoelectrons. 600 500 400 σ [psec] 300 200 100 200 500 1000 2000 Number of photoelectrons Figure 5. Timing resolution of the small prototype as a function of the total number of observed photoelectrons. According to the simulation by GEANT3 [9], the final detector will observe about 20, 000 photoelectrons for 52.8-MeV γ. It is not straightforward to extrapolate to such high energy since the distribution of PMT outputs observed by the final detector is quite different. The timing resolution of 50 psec is, however, reasonably expected for 52.8-MeV γ. ozone: submitted to World Scientific on February 15, 2005 6

4 Large Prototype The first small prototype was constructed so as to examine performance of the liquid Xe detector for low energy γ-rays, because such a large liquid Xe scintillation detector had not been constructed. The next step was to construct a larger prototype to proof the detector performance for higher energy γ-rays. The large prototype can be regarded as a minimal part of the final detector, and indeed includes various components of the final detector such as feedthrough connectors, temperature and pressure monitors, and a xenon liquefaction system including refrigerators. It is also important to examine them. A schema of the large prototype is shown in Fig. 6. The second prototype has an active volume of 372 372 496 mm 3 (68.6 liter). The 228 PMTs were assembled into a rectangular shape to be inserted into the vessel. Instead of copper cooling pipe as used in the small prototype, a pulse tube refrigerator [10] was employed to keep liquid xenon stable. Stability of the PMTs was monitored with α sources and blue LEDs equipped on the PMT holder. PMT holder H.V. Signal Vacuum / Xenon Liquid Nitrogen Refrigerator 2 inch PMT (x 264) SUS honeycomb window Thin Al window γ beam Capacitance level meter Vacuum for thermal insulation Liquid Xenon Holding rail Vacuum pump Stand Al spacer G 10 spacer 0 cm 100 cm Figure 6. A schematic view of the second large prototype. ozone: submitted to World Scientific on February 15, 2005 7

Compton backscattered γ-rays will be used to investigate the detector performance in the TERAS electron storage ring [11] at the National Institute of Advanced Industrial Science and Technology (AIST). Photons from Nd:YFL laser are led to a head-on collision point at TERAS to deliver γ-rays of energies up to 40 MeV. Energy resolution of the detector will be derived by means of measuring the spread of the Compton edge. For evaluating the timing resolution, the signal from the master oscillator for the RF cavities in the storage ring will be employed as a reference of the timing. The position resolution will be also evaluated with a proper collimator setup. The tests with this prototype have just started. In fact, the preliminary test for the large prototype was performed at AIST in 2001 in order to examine the whole system of the large prototype. In this test it was verified that all components of the large prototype worked well. Now the large prototype is ready for the next test, and more extensive studies will continue until the summer of 2002. 5 Summary Research and development works on the liquid Xe detector is in progress for the µ + e + γ search experiment at PSI. The first prototype with an active volume of 2.3 liter was successfully constructed and various tests were performed using γ-ray sources up to 1.8 MeV. The results show that it is feasible to achieve the required resolutions for the experiment. The second prototype with an active volume of 69 liter was constructed to verify the detector performance for higher energy γ-ray. Extensive studies with the large prototype will continue using γ-ray provided at AIST, cosmic rays, and α source. Acknowledgments We would like to thank Dr. H. Ohgaki and Dr. H. Toyokawa at AIST, who supported and helped us during the second prototype test. This work is supported in part by Grant-in-Aid for Scientific Research on Priority Areas (A) provided by the Ministry of Education, Culture, Sports, Science and Technology of Japan. References 1. R. Barbieri and L.J. Hall, Phys. Lett. B338(1994) 212. 2. R. Barbieri, L.J. Hall and A. Stumia, Nucl. Phys. B445(1995)219. ozone: submitted to World Scientific on February 15, 2005 8

3. MEGA Collaboration, M,L, Brooks, Phys. Rev. Lett. 83(1999) 1521. 4. T. Mori et al, Search for µ eγ down to 10 14 branching ratio, Research Proposal, May 1999. 5. W. Ootani s talk in the workshop NOON2001. 6. T. Doke, Nucl. Instr. and Meth. A327(1993) 113. 7. R6041Q, Hamamatsu Photonics K. K., Shizuoka 438-0193, Japan. 8. W. R. Nelson, H. Hirayama and D. W. O. Rogers, The EGS4 Code System, SLAC-256(1985). 9. T. Haruyama s talk in this workshop. 10. GEANT, Detector Description Simulation Tool, CERN Program Library. 11. H. Ohgaki et al., Nucl. Instr. and Meth. A375(1996) 602. ozone: submitted to World Scientific on February 15, 2005 9