Using the Agilent 7000B Triple Quadrupole GC/MS for Parts per Trillion Detection of PAH Metabolites in Human Urine

Similar documents
ENVIRONMENTAL analysis

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Determination of 24 PAHs in Drinking Water

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System

The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

PAH Analyses with High Efficiency GC Columns: Column Selection and Best Practices

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Rapid, Robust, and Sensitive Detection of 11-nor-D 9 - Tetrahydrocannabinol-9-Carboxylic Acid in Hair

Determination of Cannabinoids (THC) in Biological Samples

Author. Abstract. Introduction

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Highly Sensitive and Rugged GC/MS/MS Tool

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Application Note. Agilent Application Solution Analysis of PAHs in soil according to EPA 8310 method with UV and fluorescence detection.

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Determination of Volatile Aromatic Compounds in Soil by Manual SPME and Agilent 5975T LTM GC/MSD

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Application Note. Abstract. Authors. Environmental

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

CALIBRATION OF GC/MS METHOD AND VALIDATION OF THE MODIFIED SAMPLE PREPARATION FOR DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS

Application Note. Abstract. Authors. Environmental

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Analysis of BTEX in Natural Water with SPME

Sensitive Detection of Pyrethroids in Surface Water and Sediment

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Fast Screening and Quantitation of Perfluorinated Sources from Textiles using Chemical Ionization GC-MS

Signal, Noise, and Detection Limits in Mass Spectrometry

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

GC Analysis of Polybrominated Flame Retardants Application

AppNote 2/2000. Stir Bar Sorptive Extraction (SBSE) applied to Environmental Aqueous Samples

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

Confirmation and Quantitation of THC in Oral Fluid Using an MRM Method on a GC-Triple Quadrupole MS

Selection of a Capillary GC Column

Analysis of Extractable and Leachable (E&L) Compounds Using a Low-Energy EI-Capable High Resolution Accurate Mass GC/Q-TOF

Application Note. Abstract. Authors. Introduction

FORMIC ACID in URINE by GC/MS-headspace - Code GC74010

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Selection of a Capillary

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Application Note. Author. Abstract. Introduction. Hydrocarbon Processing

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

Method of determination of phtalates in spirituous beverages by gaschromatography/mass

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

Xinyu LIU, Peter JOZA, Andrew MASTERS, Bill RICKERT

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Analysis of Cannabinoids and Amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source. Application.

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Determination of polynuclear aromatic hydrocarbons (PAHs) in selected water bodies in the Niger Delta

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis

Food analysis. Solutions for Your Analytical Business Markets and Applications Programs

GC/MS/MS Dioxin and Dioxin-like PCBs in Feed and Food. Jessica Westland, LSAG Applications Chemist

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs)

Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Application Note. Authors. Abstract. Xin Sun Shandong Agriculture University, Taian, , China

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Benzoylecgonine in Urine by SAMHSA GC/MS

This project has been funded with support from the European Commission. This publication reflects the views only of the authors, and the Commission

Opiates in Urine by SAMHSA GC/MS

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

SPME-GC-MS/MS for Identification and Quantification of Migration Contaminants in Paperboard Food Packaging

Determination of iopromide in environmental waters by ion chromatography-icp-ms

Transcription:

Using the Agilent 7000B Triple Quadrupole GC/MS for Parts per Trillion Detection of PAH Metabolites in Human Urine Application Note Environmental Authors Éric Gaudreau, Jean-François Bienvenu, René Bérubé, Éric Daigle, and Simon Chouinard Centre de Toxicologie du Québec Institut National de Santé Publique du Québec Québec Canada Abstract A method was developed for sensitive and robust monitoring of very low levels of polycyclic aromatic hydrocarbons (PAH) metabolites in urine using the Agilent 7000B Triple Quadrupole GC/MS System. The resulting limits of detection (LODs) were as low as 0.7 parts per trillion (ppt), and limits of quantitation (LOQs) were as low as 2.5 ppt, with nearly 100% recovery for all 19 PAH metabolites. This method was developed for current use by the Canadian Health Measures Survey (CHMS). Marcus Kim Agilent Technologies, Inc. Mississauga Canada

Introduction PAHs make up a class of more than 100 chemicals composed of up to six benzene rings fused together such that any two adjacent benzene rings share two carbon bonds. Burning carbon-containing compounds is the primary source of PAHs. PAHs are in gasoline and diesel exhaust, soot, coke, cigar, and cigarette smoke. Foods that contain small amounts of PAHs include smoked, barbecued or charcoal-broiled foods, roasted coffees, and sausages. PAHs are a human health concern because a number of studies have shown increased incidence of cancer (lung, skin, and urinary cancers) in humans exposed to PAH mixtures [1]. Many individual PAH compounds have been classified as probable or possible carcinogens by entities such as the U.S. DHHS National Toxicology Program, the U.S. Environmental Protection Agency (EPA) and Health Canada. The effects on human health depend mainly on the extent of exposure (length of time, and so forth), the amount one is exposed to (or concentration), the innate toxicity of the PAHs, and whether exposure occurs through inhalation, ingestion, or skin contact. A variety of other factors can also affect health impacts from such exposure, including pre-existing health status and age. Biological monitoring of exposure through the analysis of urinary levels of PAH metabolites has become an increasingly popular means of estimating the absorbed dose [2]. PAHs are rapidly hydroxylated in the liver (phase 1 metabolism) and then undergo conjugation, typically to the glucuronide, which makes them more water soluble for excretion in urine [3]. Several industrial hygiene studies have shown that 1-hydroxypyrene in urine is a valid biomarker for occupational exposure to PAHs. Furthermore, the determination of the benzo[a]pyrene metabolite concentration in human urine can be used as an indicator for PAH contamination [4, 5]. Since these compounds are considered priority contaminants in Canada, methods have been developed to assess environmental exposure to PAHs by monitoring the metabolized products in urine. measurement of hydroxylated PAH metabolites in human urine using an Agilent 7890 GC coupled to an Agilent 7000B Series Triple Quadrupole GC/MS System, using gas chromatography and mass spectrometry with multiple reaction monitoring (GC/MS/MS). LOQs are as low as 0.0025 µg/l (2.5 parts per trillion; ppt), and do not exceed 12 ppt, with the exception of 2-napthol. Most recoveries are in the 94 to 104% range, and intra-day and inter-day precision (relative standard deviation) does not exceed 10% for any of the 19 metabolites analyzed. Experimental Standards and reagents Hydroxybenz[a]anthracene, hydroxybenzo[a]pyrene, hydroxychrysene, hydroxyfluoranthene, and their respective isomers were obtained from Midwest Research Institute (Kansas City, MO). The hydroxyfluorene and naphthol isomers were obtained from Sigma-Aldrich (St. Louis, MO). Hydroxyphenanthrene, hydroxypyrene, and their respective isomers were obtained from Dr. Ehrenstorfer GmbH (Augsburg, Germany). All 13 C labeled standards were obtained from Cambridge Isotope Laboratories (Andover, MA) except for 3-hydroxyfluoranthene- 13 C 6, which was obtained from Midwest Research Institute (Kansas City, MO). All deuterium labeled standards were obtained from Toronto Research Chemicals (Toronto, Canada). The b-glucuronidase enzyme (in water) was obtained from Sigma-Aldrich, and the urine samples were obtained from non-exposed volunteers. The derivatization agent N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA) was obtained from Thermo Fisher Scientific. The internal standards used, and their respective analytes, are shown in Table 1. Table 1. Internal standard 1-napthol- 13 C 6 2-napthol- 13 C 6 Labeled Internal Standards Associated with their Analytes for Quantitation Analyte 1-napthol 2-napthol This application note describes development of a method for 2-fluorene-d 9 3-OH-phenanthrene- 13 C 6 9-OH-phenanthrene- 13 C 6 3-OH-fluoranthene- 13 C 6 1-OH-pyrene- 13 C 6 6-OH-chrysene- 13 C 6 3-OH-benzo[a[pyrene- 13 C 6 2,3, and 9-OH-fluorene 1,2,3, and 4-OH-phenanthrene 9-OH-phenanthrene 3-OH-fluoranthene 1-OH-pyrene 2,3,4, and 6-OH-chrysene 1 and 3-OH-benz[a]anthracene 3-OH-benzo[a]pyrene (3-OH-BaP) 2

Sample Preparation Samples of 5 ml of urine were collected and urinary metabolites were digested with b-glucuronidase. All samples were then extracted with hexane at neutral ph and derivatized with N-Methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA). Instruments The study was performed on a 7890A gas chromatograph equipped with a Multi-Mode Inlet (MMI) and coupled to an Agilent 7000B Series Triple Quadrupole mass spectrometer, using Multiple Reaction Monitoring (MRM) and Electron Ionization (EI) acquisition modes. Table 2 shows the instrument conditions. Results Separation The hydroxy-pahs are positional isomers (for example, 4-OH-chrysene and 6-OH-chrysene and so forth) and the isomers, while differing in retention times, all have the same MS/MS transitions within each isomer group (Figures 1 and 2). Coeluting interferences would affect quantitation and detection limits, and thus good chromatographic separation is critical. The gas chromatographic method was optimized to ensure sharp, Gaussian peak shapes, and good separation of analyte peaks from interference peaks (Figure 3). Table 2. Agilent 7890/ 7000 Gas Chromatograph and Mass Spectrometer Conditions GC run conditions Analytical column Agilent DB-XLB 30 m 0.25 mm, 0.10 µm (p/n 122-1231E) Injection 1 µl; pulsed splitless Injector temperature gradient Carrier gas Oven temperature gradient Transfer line temperature 250 C Total run time MS conditions Acquisition mode Tune EMV gain Collision gas flow 130 C for 0.1 minute 720 C/min to 270 C Helium, constant flow, 1 ml/min 65 C for 1 minute 15 C/min to 160 C 5.3 C/min to 270 C 40 C/min to 320 C 2-minute hold 31.67 minutes Electron Ionization (EI), Multiple Reaction Monitoring atunes.eiex.tune.xml 15 for naphthols; 50 for 3-OH-B[a]P; 40 for remaining time segments Nitrogen, 1.5 ml/min Quenching gas flow Helium, 2.5 ml/min Source temperature 230 C 3

1 and 2 naphthol +EI MRM CID @ **(216.1 -> 201.1) 1 2 3 4 5 9, 3, and 2-hydroxyfluorene +EI MRM CID @ 15.0 (239.1 -> 165.1) 1 2 3 4 5 4, 9, 3, 1, and 2-hydroxyphenanthrene +EI MRM CID @ 15.0 (251.1 -> 235.1) 1 2 3 4 5 3-hydroxyfluoranthene and 1-hydroxypyrene +EI MRM CID @ 20.0 (290.1 -> 73.1) 1 2 3 4 5 1-hydroxybenz[a]anthracene, 4, 6, and 3-fydoxychrysene, 3-hydroxybenz[a]anthracene, 2-hydroxychrysene +EI MRM CID @ **(316.2 -> 301.2) 1 2 3 4 5 3-hydroxybenzo[a]pyrene +EI MRM CID @ **(340.2 -> 73.1) 1 2 3 4 5 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Acquisition time Figure 1. Chromatograms for all hydroxy PAHs in their respective time segments. 10 4 2.25 2.00 1.75 1.50 1.25 1.00 1.75 0.50 0.25 0 +MRM (316.2 -> 301.2) 981232.D Ratio = 97.7 (66.7%) 4-OH-chrysene 1-OH-benz[a]anthracene 25.996 25.897 6-OH-chrysene 25.8 25.9 26.0 26.1 26.2 Acquisition time (min) Figure 2. Representative chromatogram for the separation of three of the hydroxy PAHs. 4

10 4 1.2 +MRM (290.1 -> 73.1) 923448.D 19.628 min 1-OH-pyrene 10 3 1.75 +MRM (275.1 -> 259.1) 923448.D Ratio = 13.6 (92.4%) 19.627 min 1-OH-pyrene qualifier 1.0 1.50 0.8 0.6 0.4 0.2 Interference 1.25 1.00 0.75 0.50 0.25 0 0 19.5 19.6 19.7 19.8 19.9 20.0 Acquisition time (min) 19.5 19.6 19.7 Acquisition time (min) 19.8 19.9 20.0 Figure 3. Good chromatographic separation of interference from 1-OH-pyrene quantifier and qualifier ions. To meet the required sensitivity for the method, a minimum signal-to-noise ratio of 10 must be obtained for 3-OH-benzo[a]pyrene at a concentration of 0.01 µg/l (Figure 4). Hydroxylated benzo[a]pyrene was chosen because of its noted toxicity and because it is actively monitored in the environment. The extremely low detection limit in urine for 3-OH-benzo[a]pyrene is required because the major route of excretion is through feces (up to 90%) [6]. 10 3 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 +MRM (340.2 -> 73.1) 923449.D 27.785 min 3-OH-BaP (S/N = 17.3) Figure 4. 27.7 27.8 27.9 28.0 Acquisition time (min) Sensitivity of 3-OH-BaP demonstrating 17.3 signal-to-noise (S/N) at 10 parts per trillion. 5

Quantitation Calibration curves for hydroxy PAHs provided more accurate results when generated in urine rather than in a solvent such as benzene, presumably due to the possible adsorption of hydroxy-pahs on the glass vial in benzene and possible interactions with active sites within the GC flow path. All samples, including calibration standards, were treated with the enzyme b-glucuronidase. It has been reported that the hydroxy-pahs are more than 90% conjugated in urine [6]. However, curves determined with urine treated with or without b-glucuronidase were essentially identical (Figure 5). It is important to use the appropriate internal standard for each analyte to maximize accuracy of quantitation. For example, changing from the deuterated forms of internal standards (1 and 2-naphthol-d 7 ) to the 13 C forms (1 and 2-naphthol- 13 C 6 ) helps to better monitor the native forms (Table 1). Stability of Analytes in Urine Samples Preliminary results suggest that all hydroxy-pahs are stable for at least six weeks when stored below 20 C. At room temperature, free hydroxy-pahs appear to be less stable than the conjugated forms (Figure 6), and some of the hydroxy PAHs degrade over a three to six week period at room temperature, even in the conjugated form (Figure 7). Therefore, all urine samples were stored below 20 C. Response factor 30 25 20 15 10 5 1-naphthol y = 0.598x + 0.000 R² = 1.000 y = 0.587x + 0.020 R² = 1.000 Urine with b-glucuronidase Urine without b-glucuronidase 0 0 10 20 30 40 50 Concentration (ug/l) Figure 5. Representative calibration curves for 1-napthol, illustrating the nearly identical curves obtained in the presence or absence of b-glucuronidase. Conjugated and free 1-OH-pyrene 0.60-80 C 20 C 4 C RT -80 C Free 20 C Free 4 C Free RT Free 0.50 Conjugated 1-OH-phenanthrene 80 C 20 C 4 C RT 0.50 Free 0.40 Concentration (µg/l) 0.40 0.30 0.20 Conjugated Concentration (µg/l) 0.30 0.20 0.10 0.10 0.00 0 1 2 3 4 5 6 7 Week Figure 6. Reduced stability of the free form of a hydroxy-pah versus the conjugated form. 0.00 0 1 2 3 4 5 6 7 Week Figure 7. Stability as a function of time of the conjugated form of a hydroxy-pah at various storage temperatures. 6

Method Performance This method provides excellent sensitivity and recoveries, as well as intra- and inter-day precision for 19 hydroxy-pahs (Table 3). LODs are as low as 0.7 parts per trillion (ppt; 0.0007 µg/l), LOQs are as low as 2.5 ppt, and, with the exception of 2-napthol, only two exceed 11 ppt. The linearity of quantita- tion is nearly five orders of magnitude. All but one of the recoveries are in the 94 to 104% range. Intra-day precision relative standard deviation (RSD) does not exceed 6.5% and is as low as 0.8 to 0.9% for some hydroxyl-pahs. Inter-day precision does not exceed 10% and is as low as 3 5% for several analytes. Table 3. Method Performance Precision Analyte Limit of detection (µg/l) Limit of quantitation (µg/l) Linearity (µg/l) Recovery (%) Concentration (µg/l) Intra-day (%RSD*) Inter-day (%RSD*) 1-OH-benz[a] anthracene 0.0023 0.0076 LOQ to 10 97 0.022 2.7 9.4 3-OH-benz[a] anthracene 0.0018 0.0061 LOQ to 10 98 0.020 3.2 7.2 3-OH-benzo[a]pyrene 0.0014 0.0048 LOQ to 10 102 0.020 4.1 8.8 2-OH-chrysene 0.0028 0.0095 LOQ to 10 103 0.030 4.1 8.8 3-OH-chrysene 0.0025 0.0082 LOQ to 10 102 0.022 4.3 7.0 4-OH-chrysene 0.0033 0.0110 LOQ to 10 98 0.020 5.3 9.1 6-OH-chrysene 0.0027 0.0091 LOQ to 10 94 0.024 5.3 6.6 3-OH-fluoranthene 0.0020 0.0067 LOQ to 10 104 0.039 6.3 9.9 2-OH-fluorene 0.0019 0.0062 LOQ to 10 97 0.120 0.8 4.0 3-OH-fluorene 0.0007 0.0024 LOQ to 10 96 0.044 0.9 5.2 9-OH-fluorene 0.0027 0.0089 LOQ to 10 98 0.120 0.8 9.7 1-OH-phenanthrene 0.0020 0.0680 LOQ to 10 101 0.100 1.7 2.7 2-OH-phenanthrene 0.0016 0.0052 LOQ to 10 99 0.062 2.1 5.3 3-OH-phenanthrene 0.0016 0.0054 LOQ to 10 98 0.057 1.5 3.8 4-OH-phenanthrene 0.0007 0.0025 LOQ to 10 98 0.015 2.7 5.2 9-OH-phenanthrene 0.0030 0.0100 LOQ to 10 114 0.030 5.3 9.0 1-OH-pyrene 0.0014 0.0048 LOQ to 10 98 0.044 1.8 6.5 1-naphthol 0.0260 0.0860 LOQ to 10 98 1.800 2.4 7.4 2-naphthol 0.0400 0.1300 LOQ to 10 100 1.900 0.9 6.5 *%RSD percent relative standard deviation 7

Conclusion A highly sensitive and reproducible GC/MS/MS method for reliable monitoring of PAH metabolite levels in human urine has been developed on the 7000 Series Triple Quadrupole GC/MS System. The method parameters have been optimized to provide maximum separation, freedom from matrix effect, five orders of magnitude dynamic range, high recoveries, and part per trillion sensitivity. This method is currently used for the CHMS. References 1. The Superfund Research Center, Oregon State University, (http://oregonstate.edu/superfund/about_pahs) accessed June 26 2012. 2. M. Bouchard, L. Pinsonneault, C. Tremblay, J.P. Weber, Biological monitoring of environmental exposure to polycyclic aromatic hydrocarbons in subjects living in the vicinity of a creosote impregnation plant. Int Arch Occup Environ Health 74, 505-513 (2001). 3. C. Anyakora, F. Babalogbon, U. Obiakor, I. Afolami, H. Coker, Phase 1 metabolites of polynuclear aromatic hydrocarbons in blood samples of exposed subjects. Sci Res and Essay 3, 254-258 (2008). 4. F.J. Jongeneelen, Biological monitoring of environmental exposure to polycyclic aromatic hydrocarbons; 1- hydroxypyrene in urine of people. Toxicol. Lett. 72, 205 211 (1994). 5. B.A. Hatjian, J.E. Edwards, J. Harrison, F.M. Williams, P.G. Blain, Ambient, biological, and biological effect monitoring of exposure to polycyclic aromatic hydrocarbons (PAHs). Toxicol. Lett. 77, 271 279 (1995). 6. A. Ramesh, S.A. Walker, D.B. Hood, M.D. Guillen, K. Schneider, E.H. Weyand, Bioavailability and Risk Assessment of Orally Ingested Polycyclic Aromatic Hydrocarbons Int. J. Toxicol. 23, 301-333 (2004). 7. L.C. Romanoff, Z. Li, K.J. Young, N.C. Blakely III, D.G. Patterson, C. D. Sandau, Automated Solid-Phase Extraction Method for Measuring Urinary Polycyclic Aromatic Hydrocarbon Metabolites in Human Biomonitoring using Isotope-Dilution Gas Chromatography High-Resolution Mass Spectrometry J Chromatogr B Analyt Technol Biomed Life Sci 835, 47 54 (2006). For More Information These data represent typical results. For more information on our products and services, visit our Web site at www.agilent.com/chem. www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 2012 Printed in the USA August 30, 2012 5991-0991EN