PAR Meter Instruction Manual. Product # Product # Year Warranty

Similar documents
Amplified Pyranometer SP-212 & 215

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

SP-LITE SILICON PYRANOMETER INSTRUCTION MANUAL

Digital Multi-Day Max/ Min/Current Air and Soil Temperatures Protocol

SIMBAD RADIOMETER - INSTRUCTIONS

Measuring & Monitoring Pn. Light Roberto Lopez, Purdue Univ.

CM3 PYRANOMETER INSTRUCTION MANUAL

Today s Weather 24 Hour Forecaster

INSTRUCTION MANUAL. SP Lite2 Pyranometer. August Copyright 2017 Campbell Scientific (Canada) Corp.

Digital Multi-Day Soil Temperatures Protocol

To Set Time: Turn the set knob on back of the clock movement in either direction.

IRTS-P PRECISION INFRARED TEMPERATURE SENSOR INSTRUCTION MANUAL

Rapid RH Portable ph Meter. User's Manual

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

WS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Structure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor

U.S. Atomic Clock & Weather Station. Instruction Manual

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

GS110. IR Thermal Imaging System for Low-Emissivity Glass with Automatic Emissivity Correction. Manual Addendum

MAGMA NOTE! 21+ USER MANUAL

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

MARINE BINOCULARS ZHUMELL 7X50 MARINE BINOCULARS WITH COMPASS AND RETICLE

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

MET ONE RAIN GAGE MODELS 380, 385, 380M, 385M

iweathar EDGE V Installation Guide Copyright 2012 iweathar. All rights reserved.

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

SUGAR/BRIX REFRACTOMETER INSTRUCTION MANUAL

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

OPERATING INSTRUCTIONS

Toward an optimal spectral quality for plant growth and development: Interactions among species and photon flux. Bruce Bugbee Utah State University

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

STUDENT LABORATORY Plant Respiration and Photosynthesis

Second Focal Plane MOA

15 E OWNER S MANUAL PIRATE SPYGLASS BRING EM NEAR PIRATE SPYGLASS TELESCOPE 5 W 30 W 60 W 45 W

This sensor is now also available with a sturdier flat electrode which enables testing even smaller samples than the conventional electrode.

Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

RainMachine Mini- 8 Quick- Start Guide

Instruction Manual HI Refractometer for Sodium Chloride Measurements

What is the maximum distance I can have the remote sensors from the display?

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

ea980r Digital Anemometer User Manual

Hadrons Desktop U.S. Atomic Clock & Weather Station

STANDARD OPERATING PROCEDURE

MODEL HMP45C TEMPERATURE AND RELATIVE HUMIDITY PROBE INSTRUCTION MANUAL

WS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS. Figure 2. Figure 1

Multichannel Brake Infrared Temperature Sensor - Datasheet

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

Bante210 Benchtop ph Meter Instruction Manual

Instruction Manual C401/301/201/102/101. Portable Colorimeter. 99 Washington Street Melrose, MA Phone Toll Free

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

LP PYRA Installation and Mounting of the Pyranometer for the Measurement of Global Radiation:

EE 1/3.5х14 U EE 1/3.5х14 U

What Causes the Seasons?

The Vortex. Dual Use: Shooting Tactical / Hunting US Patent 8,166,696 US Patent 7,937,879. Elevation. Adjustment Dial.

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

A clock designed in close consultation with people living with Dementia.

Let light motivate your flowers

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE

Laboratory Exercise #7 - Introduction to Atmospheric Science: The Seasons

Megaman Horticulture Lighting

3B SCIENTIFIC PHYSICS

MODEL 107 TEMPERATURE PROBE INSTRUCTION MANUAL

Spectrophotometer SP-1105 #FOT-10711

Bright Advance Corporation

LEAPERS, INC. RED/GREEN DOTS

WS-9018U Wireless Weather Station. Instruction Manual

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

DAY LABORATORY EXERCISE: SPECTROSCOPY

Yield Responses to Supplemental Lighting

Instruction Manual HI Refractometer for Invert Sugar Measurements

Vantage PRO2 Quick. Reference Guide

P4Xi TACTICAL Riflescope TECHNICAL MANUAL

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Introduction Cautions

Paramaters. Resolution 0.2 m (for measurements < 25 meas. / sec )

RainMachine Touch HD- 12 Quick- Start Guide

RT-6 Riflescopes. User Guide

Microcare LCD Solar MPPT User Documentation

Wireless Weather Station Instruction Manual

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

CABLE FREE WEATHER STATION

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

The Vortex Razor HD Gen II-E 1 6x24 Riflescope

Optimizing the Photovoltaic Solar Energy Capture on Sunny and Cloudy Days Using a Solar Tracking System

NG114mm 114mm Newtonian Telescope w/ Equatorial Mount Instruction Manual

Minimum (-31) every 10 s -35 (-31)

WT-3131A Radio-controlled Analog Clock With Weather Forecast. Instruction Manual

EPOCSELFIR LACITCATiX5T TECHNICAL MANUAL

ZENITHSTAR 61 APO. Owner s Manual ver

zulu - inca - kundalini - cozmo Welcome to the Ownership of a YES Watch.

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.

Second Focal Plane MRAD

Transcription:

PAR Meter Instruction Manual Product #748200 Product #748205 1 Year Warranty

Measuring PPF with Quantum Meter Photosynthesis is driven by the number of photons between 400 and 700 nanometers (nm). This is called the Photosynthetic Photon Flux (PPF) and is measured in micromoles (µmol) per meters squared per second. PPF meters are commonly called quantum meters because a quantum refers to the amount of energy carried by a photon. Quantum Meter Models Quantum meter models available: #748200 #748205 Meter with integrated sensor Meter with remote sensor

Cleaning Debris on the meter is a common cause of low readings. Salt deposits can accumulate on a sensor from evaporation of sprinkler irrigation water and dust, which can accumulate during periods of low rainfall. Salt deposits should be dissolved and removed with vinegar and a soft cloth or q-tip. Dust and other organic deposits are best removed with water, rubbing alcohol or window cleaner. Never use an abrasive cleaner on the lens. Application Line quantum sensors are often used to quantify the variable light in greenhouses and below plant canopies because they provide a spatial average.

Using the Meter 1) Press the power button to start. The meter will turn itself off 2 minutes after button is pressed to conserve battery. 2) Choose Calibration: To select between sun and electric calibration push mode once and use up/ down to make choice. Once desired mode is blinking, press mode three more times to begin. 3) Choose Mode: To choose between SMPL and LOG modes push mode twice and use up/down to make choice. Once desired mode is blinking, press mode two more times to begin. For Automatic Measurements: Use LOG mode. Meter will power on/off to record a measurement every thirty seconds. For Manual Measurements: Use SMPL mode. Press sample when you want to take a measurement. Store up to 99 manual measurements. 4) Reset Meter: From LOG or SMPL mode, press mode twice (RUN should be blinking), then while pressing down, press mode once. Caution: Resetting will erase ALL measurements

5) Review Data: Press up/down. To exit and return to present conditions and the capability to take measurements, press sample. 6) In LOG mode, every 30 minutes the meter will average the sixty 30-second measurements taken and store the average. Ninety nine 30-minute averaged measurements can be stored. Every 48 measurements (making a 24-hour period), the meter will also store a daily total. In addition, ninety nine daily averages can be stored and are available for download only. These measurements are not viewable on the meter LCD. All measurements taken in LOG mode will continue to be stored eliminating the oldest measurement. (SMPL) 99 Sample Measurements (LOG) 99 Log Measurements (LOG) 99 Daily Total Measurements Viewable on meter LCD & downloadable Downloadable Only

Spectral Response As shown in the graph below, quantum response by definition is from 400 to 700 nm and gives equal emphasis to all photons in that range. The spectral response of the par meter sensor, as well as a typical plant response, are also shown. Par Meter Quantum Response

Spectral Differences Sun System PAR par meters are calibrated for both electric light and sunlight. The difference in calibration is close to 10%. A sensor calibrated for fluorescent lamps will read about 10% low in sunlight. A sensor calibrated for sunlight will read about 10% high under fluorescent lamps. The spectral errors are less than 2% for other common electric light sources. Cool White Fluorescent Electric Calibration Calibration Reference Sunlight Calibration 10% high Metal Halide < 2% low 8% high High Pressure Sodium < 2% low 8% high Sunlight 10% low Calibration Reference

The Clear Sky Calculator is designed to determine the need for radiation sensor recalibration. It determines the intensity of radiation falling on a horizontal surface at any time of the day in any location in the world. It is most accurate when used near solar noon in the summer months. The calculator is found at www.clearskycalculator.com and is used by typing conditions into the Clear Sky model and comparing measured values with the calculated value for a clear sky. If the output of the sensor over multiple days at solar noon is consistently less than the model value (by more than 8%), the sensor should be cleaned and re-leveled. When used near solar noon over multiple clear, unpolluted days during the spring and summer months, it is estimated that the accuracy of the model can be ± 4% in all climates and locations around the world.

Example of Model Output

Characteristics Cosine Response Some of the radiation coming into a sensor at low angles is reflected, causing low readings. The convex optical disc found on meters, sensors, and line quantum sensors is designed to capture radiation at low angles and minimize cosine response errors. The cosine error for typical applications is less than 2%. Temperature Response The temperature response is less than 0.1% per degree C. This temperature error is not significant in most applications. Long-Term Stability Our research indicates that the average output increases approximately 1% per year because of changes in the optical transparency of the diffusion disk. We recommend returning the sensor for recalibration every 2 years. Error Codes The most common error code is Error 4. The meter will display this error code on the screen if the battery voltage is too low. To replace the battery, unscrew the back area on the meter. Then use a pair of tweezers to gently remove the battery and replace it with a new one. Screw the back cover back on the meter, but be careful not to over-tighten as it can affect the LCD screen.

Specifications Application Measuring Photosynthetic Photon Flux (PPF) Measurement Range 0 to 2999 µmol m Input Power CR2320 3 V coin cell battery Operating Environment 0 to 50 C Less than 90% non-condensing relative humidity up to 30 C Less than 70% relative humidity from 30 to 50 C Display 4.5 cm width by 2.8 cm height Cable (for #748205) 2 meters of twisted-pair wire Foil shield Santoprene jacket Longer cable lengths are available in multiples of 5 meters Dimensions 12.6 by 7.0 by 2.4 cm Mass #748200: 150 g #748205: 180 g Warranty 1 year against defects in materials and workmanship

DISTRIBUTED BY www.sunlightsupply.com