Coriolis Mass Flow Measurement System promass 60 (HART)

Similar documents
DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Electromagnetic Flowmeter

tekcor TKC Multivariable Coriolis Flow Sensors

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

ED 701 General Industry Pressure Transmitter

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis mass flowmeter

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis mass flowmeter

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Pressure transmitters for industrial applications MBS 32 and MBS 33

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

Pressure Transmitter ED 701

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Tecnología en Electrónica y Control SRL Ficha Técnica

THM80X Series Feature Application. Temperature & Humidity / Flow Measuring Specialist

DOG-1/-3. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air : 120 C. p max. : PN 40; t max

Reflex-Radar BM 100 A

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

VersaFlow Ultrasonic clamp-on Flowmeter Specifications

Industrial Pressure Transmitter

VA Master FAM540 Metal Cone Variable Area Flowmeter

Dimensional drawing face mount flange radial. R = bending radius min. 40 mm. Dimensional drawing face mount flange axial

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Capacitive Sensors. Contents

Conductivity sensor for hygienic applications

Industrial Pressure Transmitter

Operating Instructions for Digital Manometer. Model: MAN-SD

Direct-operated 2/2-way solenoid valves Type EV210B

Integral V-Cone Flowmeter VD series

Linearity of Coriolis Flowmeters at Full Scale Value. Dr. Jesús Aguilera - Endress + Hauser Paul Ceglia - Endress + Hauser

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

MODEL: CR002, CR003, CR004. ADC12 Display shield. Liquid (Density range: 0.3 to 2.0g/mL) Operating temperature range

Evaluating New Generation Vibrating Tube Sensor for Density Measurement under Process Conditions

DRS 61: Incremental encoders, number of lines and zero pulse width freely programmable DRS 60: Incremental Encoders with Zero-Pulse-Teach

VOLUMEC. Valve Position Indicator 5

ISEmax CAM40/CAS40. Technical Information

BTE5000 / PTE5000 / PTU5000 Series Precision differential pressure transmitters

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

Pressure Measurement Single-range transmitters for general applications

Its modular concept allows to build up a ball valve for any degree of automation and any kind of application

Volumetric Flow Measurement

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Installation guide 862 MIT / MIR

SmartLine Radar Level Meter RM70

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

FLOW SENSOR FOR LIQUID MEDIA Serie 210

AM-1000 Series COMPACT FLOWMETER

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

PAA-ANALYZERS PRINCIPLE OF OPERATION

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Rocky Mountain Measurement Seminar Denver August 20, 2015 Coriolis Meters

14:1400 (0206) KRAL Volumeter - OMG

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES

PRODUCT CATALOGUE PREssURE switch

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Direct-operated 2/2-way compact solenoid valves Type EV210A

Application Your benefits

FXP DATASHEET JUNHO 2013

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

CCS140 and CCS141. Technical Information. Sensors for free chlorine Amperometric, membrane-covered sensors for installation in the CCA250 assembly

Field IT 50T Series Transmitters

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

ABB SpA COMEM Operating Unit Strada Regionale 11, Signolo Montebello Vicentino (VI) - ITALY

Oscillation Flow Meter for Gases

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

LEVEL CONTROLS. Selection Guide. Capacitance Calculations and Data For Selecting Robertshaw Level Control Instruments and Sensing Probes

HD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

Cooling Water Flow Regulator

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

Industrial Resistance Thermometers according to DIN Model MWD

Flow Meter FVone-NP-CA. FVone-NP-CA 11 (Plug-in type) (Screw-in type) Recommended for: DN 20 DN 80 Required accessory: Cable type 31.

Ultrasonic Gas Flow Meter

Standardized Chemical Pumps. Fields of Application. Designation. Design. Operating Data. Type Series Booklet /7-10 G2 CPK-H

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

Solenoid valves 2/2-way direct-operated type EV210A

Cartridge Valves Technical Information. Quick reference

Single point load cells

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Rotary modules.

E 094 E 103 E 143. Tank top mounting Connection up to G1 Nominal flow rate up to 135 l/min e

ISEmax CAS40D. Technical Information

/2 way valves (solenoid actuated diaphragm with forced lifting) 1/4... 2

Vortex Flow Measuring System PROline prowirl 72

OEM Flow sensor for liquid media type 200

Check-Q-meter. Table of contents. Features. Functions. RE 27551/ /10 Replaces: Type FD

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

Transcription:

Technical Information TI 029D/06/en No. 5006899 Coriolis Mass Flow Measurement System promass 60 (HART) Cost-effective mass flow measurement for liquids and gases Flexible System The system can be customised to each application Wide choice of materials for process connections and measuring tubes, compatible to the fluid Simple and cost-effective installation Transmitter housing can be rotated to fit the orientation Easy to Operate All important instrument functions easily configurable: with DIP switches / local display with HART protocol Local display: all important variables easily read off Accurate Measurement Measurement accuracy for liquids: Mass flow ± 0.5 % Volume flow ± 0.2 % Measurement accuracy for gases: Mass flow ± 0.5 % 0: operable flow range Excellent repeatability Safe Operation Self-emptying measuring tubes Secondary containment vessel as standard High electromagnetic compatibility (EMC) Self-monitoring with alarm function EEPROM stores data on power failure (no batteries required) ISO 900 manufacturer, quality assured Install Anywhere Compact design Insensitive to plant vibration Rugged and shock-proof surfaces resistant to acids and alkalis IP 67 protection for compact and remote versions Measurement independent of fluid characteristics

Measuring System Fields of Application The Promass 60 system measures the mass and volume flow of fluids having widely differing characteristics: Chocolate, condensed milk, syrup Oils, fats Acids, alkalis Varnishes, paints Suspensions Pharmaceuticals Catalytic converters, inhibitors Gases and gas mixtures The Promass 60 is used in applications wherever mass flow measurement is of critical importance: Mixing and batching of various raw materials Controlling processes Measuring of quickly changing densities Control and monitoring of product quality. The advantages of this measurement process are demonstrated by its successful use in food processing, the pharmaceutical industry, the chemical and petrochemical industries, waste disposal, energy production, gas applications, etc. Sensors Transmitter A Promass 60 Without local display (Blind version) I With local display M With wall mounting (remote version) F Compact version Remote version (up to meters) The modular Promass 60 measuring system Information on all Ex versions is available on request from your E+H Sales Centre. A DN... 4: For very small flow quantities, single tube system in SS or Alloy C-22 I... 50: Single straight tube system (titanium), completely welded version M... 80: Two straight measuring tubes (titanium), containment vessel up to bar... 25: High pressure version, system pressure up to 350 bar F...: Two slightely curved measuring tubes in SS or Alloy C-22 (only for...80), completely welded version Technical data: see pages 29 35 ti029y02 Measuring System The measuring system consists of: Promass 60 transmitter Promass A, I, M or F sensor The Promass 60 measuring system is mechanically and electronically designed for maximum flexibility with the transmitters and sensors being combined in any variation. The wide range of materials and process connections (fittings; flanges DIN, ANSI, JIS; Tri-Clamp) ensure that the measuring point can adjust to both plant and process conditions. The transmitter housing can be rotated for ease of reading and operation in any orientation. 2

Sensor Function Balanced Measuring System Two-tube systems (Promass M, F) The system balance is ensured by the two measuring tubes vibrating in antiphase. Single tube systems (Promass A, I) For single tube systems, other design solutions are necessary for system balance than for two-tube systems. Promass A: For Promass A, an internal reference mass is used for this purpose. Promass I: For Promass I, the system balance necessary for flawless measurement is generated by exciting an eccentrically located, counter-oscillating pendulum mass. This TMB TM (Torsion Mode Balanced) system is patented and guarantees accurate measurement, also with changing process and ambient conditions. The installation of Promass I is for this reason just as easy as with two-tube systems! Special fastening measures before and after the meter are therefore not necessary. Measuring Principle The measuring principle is based on the controlled generation of Coriolis forces. These forces are always present when both translational (straight line) and rotational (revolving) movement occur simultaneously. F C F C m ω v = 2 m(ω xv) = Coriolis force = mass of moving body = angular velocity = radial velocity in a rotating or oscillating system The amplitude of the Coriolis force depends on the moving mass m, its velocity v in the system and therefore its mass flow. 2 3 Two-tube system ti029y33 The Promass uses an oscillation instead of a constant angular velocity ω and two parallel measuring tubes (Promass M and F), with fluid flowing through them, are made to oscillate in antiphase so that they act like a tuning fork. The Coriolis forces produced at the measuring tubes cause a phase shift in the tube oscillation (see Figure on left): When there is zero flow, i.e. with the fluid standing still, both tubes oscillate in phase (). When there is mass flow, the tube oscillation is decelerated at the inlet (2) and accelerated at the outlet (3). As the mass flow rate increases, the phase difference also increases (A-B). The oscillations of the measuring tubes are determined using electrodynamic sensors at the inlet and outlet. The measurement principle operates independently of temperature, pressure, viscosity, conductivity or flow profile. Density Measurement The measuring tubes are continously excited at their resonant frequency. As the mass, and therefore the density, of the oscillating system changes (measuring tubes and fluid), the vibrating frequency is readjusted. The resonant frequency is thus a function of the density of the fluid and enables the microprocessor to produce a density signal. Temperature Measurement The temperature of the measuring tubes is determined and used to compensate for temperature effects. The signal produced is a function of the process temperature. Sectional view of Promass A, I, M and F sensors 3 4 8 7 A 3 2 6 7 M Housing/containment vessel 2 Manifold 3 Process connection 4 Measuring tube(s) A: curved tube I: straight tube M: 2 straight tubes F: 2 curved tubes 5 Gasket 6 Plug 7 Cable gland 8 Electrodynamic sensors 9 Excitation system 0 Pendulum mass TMB TM System (Promass I) 3 4 8 7 9 0 9 I 3 5 4 2 4 9 8 8 7 7 8 9 8 F ti029y03 3

Transmitter Function Function of the Promass 60 The Promass transmitter converts the measured values coming from the sensor into standardised output signals. The following outputs are available for these signals: Current output (with superimposed HART protocol) Pulse output Status output Auxiliary input Promass 60 can be configured as a mass or volume flowmeter. Operating Mode / Functionality Promass can be operated and configured in two, basically different ways: with DIP switches and local display with HART protocol The configuration mode is set using a special DIP switch ( DIP or HART ), and thereby also the instrument functionality. An overview of all Promass 60 instrument functions, depending on the type of configuration, can be found on page 5 ff. Configuration with DIP Switches All important instrument parameters are set using DIP switches in the transmitter (see page 7): Current range 0/4... ma End value scaling of current output Pulse weight Technical units (SI/US) Functions of the status output Creep suppression (on/off) Functions of the auxiliary input Short-cycle batching (on/off) Configuration with Local Display A local display is also available for the Promass 60 measuring system. This ensures that all important variables can be read off and controlled directly at the measuring point: Flow rate and/or totalised flow Technical units Process conditions (e.g. falling below creep limit) Mass or volume flow measurement Signal outputs exceeded Error messages Various functions can be selected and activated using the operating keys, e.g. zero point calibration, density calibration, pressure pulse suppression, etc. Configuration with HART Protocol With HART protocol, Promass 60 can be operated, configured and read in different ways: via the DXR 275 HART handheld via the Commuwin II operating program (in connection with Commubox FXA 9) via the HART Universal Commands and Common Practice Commands. LC display, 8 characters; display segments on instrument status and engineering units Set / key Activating the functions Entering of numerical values () Totalizer-Reset / + key: Setting the totalizer to zero Entering of numerical values (+) Local display Promass 60 (optional) Display-Function key: Selecting the various functions ti029y04 4

Operating Mode / Functionality HART protocol via DIP switches / Local display Commuwin II DXR 275 Process variables Mass flow display display Volume flow display display Density display display not possible (only for density adjustment) Temperature display display not possible Totalizer Totalizer display display Totalizer overflow display display Reset totalizer possible possible System info Code entry possible not possible Diagnostic code Multidrop Address (Commuwin II) display of error and status messages entry display not possible entry not possible Software version Com display display not possible Display test function not possible possible System units Volume flow measurement Mass flow unit Mass unit Volume flow unit Volume unit Density unit Temperature unit Current outputs possible freely selectable: kg/s, kg/h, lb/min, ton/hr freely selectable: kg, t, lb, ton freely selectable: l/s, l/h, Ugpm, Ugph freely selectable: l, m 3, USgal, USgal * 0 freely selectable: kg/dm 3, g/cc freely selectable: C, K, F, R possible SI or US units selectable SI or US units selectable SI or US units selectable SI or US units selectable Assign output mass or volume flow mass or volume flow Full scale value freely selectable 8 values selectable Time constant Current span freely selectable 0.0...99 s 4 ma 4 ma (NAMUR) s (fixed value) 0 ma or 4 ma Simulation current possible not possible Nominal current display display not possible 5

Operating Mode / Functionality HART protocol via DIP switches / Local display Commuwin II DXR 275 Pulse / Freq. output Assign output mass or volume flow mass or volume flow Operation mode pulse or frequency pulse or frequency Pulse value freely selectable 8 values selectable Pulse width freely selectable max. 0 s Full scale value (400 Hz) freely selectable fixed value Simulation frequency possible not possible Processing parameters Low flow cutoff freely selectable on/off switching Noise suppression Empty pipe detection (EPD threshold) Self checking (batching time <60 s) Pressure pulse suppression freely selectable between 0.00...2.00 s freely selectable selectable time period of activation freely selectable not possible not possible (no empty pipe detection) selectable on/off switching Zero point adjustment possible possible Density adjustment possible possible Density adjust value selectable selectable Assign auxiliary input Assign status output System reset Sensor data selectable: positive zero return zero point adjustment totalizer reset selectable: error message flow direction recognition possible (only with Commuwin II) selectable: positive zero return zero point adjustment totalizer reset selectable: error message flow direction recognition not possible Calibration factor read-write possible not possible Zero point selectable selectable Nominal diameter display display not possible Sensor coefficients/ values display (e.g. of density coefficients C0...C5) display not possible Serial number display display not possible Software version display display not possible 6

Scaling the Outputs with DIP Switches SI units [g, kg, t] MASS Pulse value MASS DN ON OFF 2 4 8 5 5*/25 25*/40 40*/50 80 0.000 g 0.0 g 0. g g g 0 g 0 g 0 g g kg 0.00 g 0. g g 0 g 0 g g g g kg 0 kg 0.0 g g 0 g g g kg kg kg 0 kg kg 0. g 0 g g kg kg 0 kg 0 kg 0 kg kg t g g kg 0 kg 0 kg kg kg kg t 0 t 0 g kg 0 kg kg kg t t t 0 t t g 0 kg kg t t 0 t 0 t 0 t t 0 t 0.0000 kg 0.000079 kg 0.00034 kg 0.00257 kg 0.00448 kg 0.02272 kg 0.0346 kg 0.049087 kg 0.25664 kg 0.96350 kg US units [lb] 2 4 8 5 5*/25 25*/40 40*/50 80 0.000000 0.0000 0.000 0.00 0.00 0.0 0.0 0.0 0. 0.00000 0.000 0.00 0.0 0.0 0. 0. 0. 0 0.0000 0.00 0.0 0. 0. 0 0.000 0.0 0. 0 0 0 0 0.00 0. 0 0 0 00 0.0 0 0 0 0 00 000 0. 0 0 0 00 00 00 000 0000 0.000043 0.00074 0.000697 0.002787 0.009797 0.02723 0.069665 0.0885 0.278659 0.435397 * DN 5, 25, 40 FB = Full bore versions Promass I The various pulse value and full scale values are set using the DIP switches inside the housing (electronics area) see page 7. MASS Full scale value (current output) If a different pulse- or full scale value, than the selection given with the DIP switches is required, the meter can be configured via HART see page 4. On request, Promass 60 measuring instruments are also available with customised parameterisation. SI units [kg/h] DN 2 4 8 5 5*/25 25*/40 40*/50 80 ON OFF 5 300 0 00 4000 9000 4000 2 0 40 0 600 00 4000 8000 8000 28000 3 5 60 300 900 3000 6000 00 27000 400 4 80 400 0 4000 8000 6000 36000 56000 5 25 500 500 5000 00 000 45000 70000 0 50 0 0 3000 00 000 40000 90000 40000 6 80 3 600 4800 6000 300 64000 44000 224000 400 00 6000 000 40000 80000 80000 280000 US units [lb/min] 2 4 8 5 5*/25 25*/40 40*/50 80 0.05 0. 0.75 4.00 0.00 30.00 75.00 25.00 325.00 425.00 0.0 0.40.50 8.00.00 60.00 50.00 250.00 650.00 850.00 0.5 0.60 2.25 2.00 30.00 90.00 225.00 375.00 975.00 275.00 0. 0.80 3.00 6.00 40.00.00 300.00 500.00 300.00 700.00 0.25.00 3.75.00 50.00 50.00 375.00 625.00 625.00 225.00 0.50 2.00 7.50 40.00.00 300.00 750.00 250.00 3250.00 4250.00 0.80 3. 2.00 64.00 60.00 480.00 0.00 00.00 50.00 6800.00.00 4.00 5.00 80.00 0.00 600.00 500.00 2500.00 6500.00 8500.00 * DN 5, 25, 40 FB = Full bore versions Promass I Factory settings (grey shaded area) 7

Scaling the Outputs with DIP Switches VOLUME SI units [ml, l, m 3 ] VOLUME Pulse value DN ON OFF The various pulse values and full scale values are set using the DIP switches inside the housing (electronics area) see page 7. If a different pulse- or full scale value, than the selection given with the DIP switches is required, the meter can be configured via HART see page 4. On request, Promass 60 measuring instruments are also available with customised parameterisation. 2 4 8 5 5*/25 25*/40 40*/50 80 0.000 ml 0.0 ml 0. ml ml ml 0 ml 0 ml 0 ml ml l US units [USgal] 0.00 ml 0. ml ml 0 ml 0 ml ml ml ml l 0 l 0.0 ml ml 0 ml ml ml l l l 0 l l 0. ml 0 ml ml l l 0 l 0 l 0 l l m 3 ml ml l 0 l 0 l l l l m3 0 m 3 0 ml l 0 l l l m3 m 3 m 3 0 m 3 m 3 ml 0 l l m3 m 3 0 m 3 0 m 3 0 m 3 m 3 0 m 3 0.0000 l 0.000079 l 0.00034 l 0.00257 l 0.00448 l 0.02272 l 0.0346 l 0.049087 l 0.25664 l 0.96350 l 2 4 8 5 5*/25 25*/40 40*/50 80 0.000000 0.0000 0.000 0.00 0.00 0.0 0.0 0.0 0. 0.00000 0.000 0.00 0.0 0.0 0. 0. 0. 0 0.0000 0.00 0.0 0. 0. 0 0.000 0.0 0. 0 0 0 0 0.00 0. 0 0 0 00 0.0 0 0 0 0 00 000 0. 0 0 0 00 00 00 000 0000 0.000005 0.00002 0.000083 0.000334 0.0074 0.00326 0.008348 0.03043 0.03339 0.05273 * DN 5, 25, 40 FB = Full bore versions Promass I VOLUME Full scale value (current output) SI units [l/h] DN ON OFF 2 4 8 5 5*/25 25*/40 40*/50 80 5 300 0 00 4000 9000 4000 2 0 40 0 600 00 4000 8000 8000 28000 3 5 60 300 900 3000 6000 00 27000 400 4 80 400 0 4000 8000 6000 36000 56000 5 25 500 500 5000 00 000 45000 70000 0 50 0 0 3000 00 000 40000 90000 40000 6 80 3 600 4800 6000 300 64000 44000 224000 400 00 6000 000 40000 80000 80000 280000 US units [USgal/min] 2 4 8 5 5*/25 25*/40 40*/50 80 0.005 0.025 0. 0.500.500 4.000 0.000 5.000 40.000 50.000 0.00 0.050 0.0.000 3.000 8.000.000 30.000 80.000.000 0.05 0.075 0.300.500 4.500 2.000 30.000 45.000.000 50.000 0.0 0. 0.400 2.000 6.000 6.000 40.000 60.000 60.000 0.000 0.025 0.25 0.500 2.500 7.500.000 50.000 75.000 0.000 250.000 0.050 0.250.000 5.000 5.000 40.000.000 50.000 400.000 500.000 0.080 0.400.600 8.000 24.000 64.000 60.000 240.000 640.000 800.000 0. 0.500 2.000 0.000 30.000 80.000 0.000 300.000 800.000 0.000 * DN 5, 25, 40 FB = Full bore versions Promass I Factory settings (grey shaded area) 8

Mounting No special fittings such as brackets are needed. External forces are absorbed by the construction of the device, e.g. the secondary containment vessel. The high frequency oscillation of the measuring tubes ensures that correct operation of the measuring system is unaffected by plant vibration. When mounting, no special precautions need to be taken for turbulencegenerating devices (valves, bends T-pieces, etc.) as long as no cavitation occurs. Orientation (Promass A) Vertical This is best with the flow direction upwards. Entrained solids sink downward and gases rise away from the measuring tube. This also allows the measuring tube to be completely drained and protects it from solids build-up. Horizontal When correctly installed, the transmitter housing is either above or below the piping. This assures that no gas bubbles may collect or solids be deposited in the curved measuring tube. Wall and post mounting The sensor may not be suspended in the piping, that is, without support or fixation to avoid excessive stress on the material around the process connection. Orientation Promass A 0...4 kg ti029y36 The sensor housing base plate allows table, wall, or post mounting. The post mounting requires a special mounting set. Promass I (can be mounted in any position) view A Orientation (Promass I, M, F) Vertical This is best with the flow direction upwards. Entrained solids sink downward and gases rise away from the measuring tubes when the product is not flowing. This also allows the measuring tubes to be completely drained and protects them from solids build-up. F F2 view A (Promass M, F) Positioning Promass F Horizontal Promass I (single tube) can be freely installed in a horizontal piping. For Promass M and F the measuring tubes must lie side by side. When correctly installed, the transmitter housing is either above or below the piping (see view A). Promass F measuring tubes are slightly curved. Therefore, the sensor position is to be adapted to the fluid properties for horizontal installation: F: not suitable for outgassing fluids F2: not suitable for fluids with solids content Orientation Promass I, M, F ti029y07 9

Mounting Storage tank Promass sensor Orifice Pipe restriction Valve Batching tank Mounting Location Air or entrained gases in the measuring tube may cause errors in measurement and therefore the following mounting installations are to be avoided: Do not install at the highest point of the piping. Do not install in a vertical pipeline directly upstream of a free pipe outlet. Correct installation is still possible using the recommendation in the adjacent figure. Restrictions in the piping or an orifice with a smaller cross section than the measuring instrument can prevent the sensor from running empty during measurement. Mounting location (vertical piping) ti029y09 Diameter DN DN 2 DN 4 DN 5 DN 5 * * * 0 DN Ø Orifice / restriction 0.8 mm.5 mm 3.0 mm 6.0 mm 0.0 mm 5.0 mm 4.0 mm 24.0 mm 22.0 mm 35.0 mm 28.0 mm 50.0 mm 65.0 mm * DN 5, 25, 40 FB Full bore versions of Promass I Zero Point adjustment To ensure accurate measurement also with very low flow rates, we recommend to carry out a zero point adjustment under process conditions. The zero point adjustment should be carried out only with the measuring tubes full and with no flow. This can be achieved with shut-off valves both upstream and downstream of the sensor (or use existing valves if present). Normal operation Open valves A and B Zero point adjustment with pumping pressure Open valve A Close valve B Zero point adjustment without pumping pressure Close valve A Open valve B Zero point adjustment and shut-off valves Carry out zero point adjustment when v meas. tube = 0 m/s only! ti029y0 0

Planning and Installation System Pressure It is important to avoid cavitation as this can affect tube oscillation. No special measures need be taken for fluids which have properties similar to those of water under normal conditions. With volatile liquids (hydrocarbons, solvents, liquefied gases) or liquids in suction lines, the vapour pressure of the liquid must not drop below a point where the liquid begins to boil. It is also important not to release gases which are found naturally in many liquids. This can be prevented by ensuring that there is sufficient system pressure. Ideally the sensor should be mounted on the descharge side of pumps (avoiding low pressure), at the lowest point of a vertical pipeline. Corrosion Resistance With corrosive liquids, the chemical resistance of all wetted parts such as measuring tubes, gaskets and process connections must be thoroughly checked. This also applies to the liquids used for cleaning the Promass sensor. Tracing, Thermal Insulation With certain products heat transfer at the sensor must be avoided. A wide range of materials can be used for the necessary insulation. Heating can be provided either electrically, e.g. by heating jackets, or supplied by copper pipes with heated water or steam. Heating elements for heat tracing are available for all sensors. Caution! Ensure that the meter electronics are not overheated. The connector between the sensor and the transmitter housings as well as the connection housing of the remote version must therefore always be kept free. Full Scale Value / Nominal Diameter The most suitable nominal diameter is selected by taking into account the measuring range required and the permitted pressure drop. The full scales values for each nominal diameter are defined on page 29. The minimum recommended full scale value is about / of the indicated max. values above. With most applications, the optimum is considered to be between...50% of the maximum full scale value. With abrasive fluids, e.g. liquids containing solids, a lower full scale value should be used (flow velocity < m/s). For gas applications the following rules applies: The flow velocity in the tubes should not exceed half of the sonic speed (mach 0.5). The maximum massflow depends on the density of the gas and can be calculated from the formula on page 29. Applicator Design Software All important instrument data are contained in the E+H software in order to optimise the design of the measuring system. The Applicator software is used for the following calculations: Nominal diameter of the sensor with regard to the characteristics of the fluid such as viscosity, density, etc. Pressure loss downstream of the measuring point Converting mass flow to volumetric flow, etc. Simultaneous display of various nominal diameters. Fluid Temperature / Orientation To ensure that the permitted ambient temperature range for the transmitter is not exceeded (25...+60 C) positioning is recommended as follows: High fluid temperature Vertical piping: Position A Horizontal piping: Position C B A Low fluid temperature Vertical piping: Position A Horizontal piping: Position B C ti029y08

Pressure Loss The pressure drop is dependent on the characteristics of the fluid and its flow rate. The following formulae can be used for liquids to approximately calculate the pressure loss: Note! Calculations on pressure loss can be carried out using the Endress+Hauser Applicator software (see page ). Promass A / I Promass M / F Reynolds No. Re = 4 m π d υ ρ Re = 2 m π d υ ρ Re 2300 * p = K υ 0.25 m.75 ρ 0.75 + K3 m2 ρ p = K υ 0.25 m.85 ρ 0.86 Re < 2300 p = K υ m + K3 m2 ρ p = K υ m + K2 υ0.25 m 2 ρ p = pressure loss [mbar] ρ = fluid density [kg/m 3 ] υ = kinematic viscosity [m 2 /s] d = internal diameter of measuring tubes [m] m = mass flow rate [kg/s] K...K3 = constants dependent on the nominal diameter * For gases the pressure loss has always to be calculated by use of the formula for Re 2300. Diameter d [m] K K K2 K3 Promass A DN DN 2 DN 4.0 0 3.80 0 3 3.50 0 3.2 0.6 0 0 9.4 0 8.3 0 2.4 0 0 2.3 0 9 0 0 0 Promass A High press. DN 2 DN 4.40 0 3 5.4 0 0 6.6 0 0 3.00 0 3 2.0 0 9 4.3 0 9 0 0 Promass I DN 5 DN 5 * * * 8.55 0 3.38 0 3 7.07 0 3 7.07 0 3 25.60 0 3 25.60 0 3 35.62 0 3 35.62 0 3 8. 0 6 2.3 0 6 4. 0 5 4. 0 5 7.8 0 4 7.8 0 4.3 0 4.3 0 4 3.9 0 7.3 0 7 3.3 0 6 3.3 0 6 8.5 0 5 8.5 0 5 2.0 0 5 2.0 0 5 29.95 0 4 23.33 0 4 0.0 0 4 5.89 0 4 0. 0 4.9 0 4 0.08 0 4 0.25 0 4 Promass M DN 5 0 5.53 0 3 8.55 0 3.38 0 3 7.07 0 3 25.60 0 3 38.46 0 3 5.2 0 7 5.3 0 6.7 0 6 3.2 0 5 6.4 0 4.4 0 4 8.6 0 7.7 0 7 5.8 0 6.2 0 6 4.5 0 5 8.2 0 4.7 0 7 9.7 0 5 4. 0 5.2 0 5.3 0 4 3.7 0 3 Promass M High press. DN 5 4.93 0 3 7.75 0 3 0. 0 3 6.0 0 7 8.0 0 6 2.7 0 6.4 0 8 2.5 0 7 8.9 0 6 2.8 0 7.4 0 6 6.3 0 5 Promass F DN 5 0 DN 5.35 0 3 8.30 0 3 2.00 0 3 7.60 0 3 26.00 0 3 40.50 0 3 5. 0 3 5.70 0 7 5.80 0 6.90 0 6 3.50 0 5 7.00 0 4.0 0 4 3.54 0 3 9.60 0 7.90 0 7 6.40 0 6.30 0 6 5.00 0 5 7.7 0 4 3.54 0 4.90 0 7 0.60 0 5 4.50 0 5.30 0 5.40 0 4.42 0 4 5.40 0 3 Pressure loss data inclusive interface measuring tube(s) / piping Pressure loss diagrams for water can be found on the following page. * DN 5, 25, 40 FB = Full bore versions of Promass I 2

Pressure Loss with Water Pressure loss [mbar] Promass A Mass flow [kg/h] Standard version High pressure version Pressure loss [mbar] Promass I Mass flow [t/h] Standard versions: inclusive interface measuring tube(s) / piping Full bore versions * Pressure loss [mbar] Promass M, F ti029y2 Promass M Promass M (High pressure version) Promass F Mass flow [t/h] 3

Electrical Connections Fuse Power supply cable Ground terminal for ground wire Ground terminal for cable screening Signal cable Ground connection (ground wire) L } for AC N L+ } for DC power supply L Pulse/frequency output (passive) Status output (passive) Auxiliary input Current output (active) 0...400 Hz (f max = 500 Hz) max. 30 V / 250 ma max. 30 V / 250 ma System error message Flow direction recognition 3...30 V DC, R i =.8 kω Positive zero return, Zero point calibration Totalizer reset 0/4... ma, R L < 700 Ω HART protocol: 4... ma, R L 250 Ω Ground connection (screening of signal cable) Electrical connections: power supply, input and outputs ti029y03 Remote version Transmitter Cable length max. m Sensor gry = grey; grn = green; yel = yellow; pnk = pink; wht = white; brn = brown Note! Technical data on Ex versions are given in separate documentation available from E+H on request. Cable specifications for the remote version 6 x 0.38 mm 2 PVC cable with common screening and individually screened cores. Conductor resistance: 50 Ω/km; Capacitance: core/screen 4 pf/m ti029e4 4

Dimensions Promass 60 A Compact version Adapter set ti029y37 Flange connection with lap joint flanges Process connection DN DN 2 DN 4 L 4-VCO-4 fittings 290 372 497 L 2" Tri- Clamp 296 378 503 L2 4" NPT-F 36 443 568 L3 SWAGELOK DN, 2: 8"or 4" DN 4: 4 " 359.6 44.6 57.6 L4 L5 2" flange (ANSI) L6 L7 DN 5 flange (DIN, JIS) Cl 50 Cl 300 PN 40 0K 393 475 600 393 475 600 393 475 600 393 475 600 Diameter DIN ANSI DN DN 2 DN 2* DN 4 DN 4* 24" 2" 2 " 8" 8 " di A B C E F G H K M Weight [kg]..8.4 3.5 3.0 32 32 32 32 32 65 65 65 95 95 269.5 269.5 269.5 279.5 279.5 50 50 45 45 45 75 75 60 60 60 2 2 30.5 30.5 30.5 3.5 3.5 All dimensions in mm; * High pressure version 80 80 80 240 240 228 30 30 435 435 0 5 5 Remote version (dimensions of the transmitter: see page 7) ti029y38 Note! Dimensions of Ex instruments are given in separate documentation available from E+H on request. Diameter DIN ANSI DN DN 2 DN 4 24 " 2" 8" B 22 22 32 N 54 54 64 L Dimensions dependent on the process connections (see above) 5

Wetted Parts Materials Measuring tube: SS.4539 (904L), Alloy C-22 2.4602 (N 06022) 4-VCO-4 fittings SS.4539 (904L), Alloy C-22 2.4602 (N 06022) / 2 " Tri-Clamp SS.4539 (904L) Adapter sets: / 8 "or / 4 " SWAGELOK SS.440 (36) / 4" NPT-F SS.4539 (904L), Alloy C-22 2.4602 (N 06022) Flange: DIN, ANSI, JIS SS.4539 (904L), Alloy C-22 2.4602 (N 06022), lap joint flanges (not wetted) SS.4404 (36L) Gaskets (O-ring) Viton (5...+0 C), EPDM (40...+60 C), Silicone (60...+0 C), Kalrez (30...+ C) Without adapter set Pressure [bar] 4-VCO-4 fittings SWAGELOK 400 360 3 280 240 0 60 DN (Alloy C-22) DN 2, 4 High pressure (.4539) DN (.4539) DN 2, 4 Standard (.4539 or Alloy C-22) -60-40 - 0 40 60 80 40 60 80 0 Temperature [ C] /2" Tri-Clamp Tri-Clamp: The material load limit is exclusively determined by the material properties of the Tri-Clamp used. This clamp is not included in the shipment. ti029y40 With adapter set /4" NPT-F Pressure [bar] DN (Alloy C-22) DN 2, 4 High pressure (.4539) DN (.4539) ti029y4 /8 " or / 4 " SWAGELOK DN 2, 4 Standard (.4539 or Alloy C-22) Flanges (ANSI, DIN, JIS) * Class 300 Cl 50 Cl 300 Class 50 PN 40 Material load curves Promass A * with / 2 " or DN 5 flanges as standard PN 40 0 K 0 K Temperature [ C] 6

Dimensions Promass 60 I, M, F Remote version Compact version Promass I...50 ti029y45 Promass M, F max. m Promass M...80 Promass I Promass F... ti029y32 Diameter L x L **** A B B di Weight [kg] DIN ANSI I M F I M F I M F I M F DN 5 DN 5* * * 0 DN ** DN *** 3 8 " 2" 2" " " 2 " 2" 2" 3" 4" 4" 6" Dimensions dependent on the process connections (see following pages) 256 286 30 40 544 644 75 75 75 05 4 0 0 247 247 288.0 288.0 288.0 288.0 30.5 30.5 36.5 36.5 262.5 264.5 268.5 279.5 289.5 305.5 305.5 262.5 262.5 262.5 267.5 279.5 30.0 30.0 3.0 3.0 38.5 38.5 38.5 38.5 52.0 52.0 67.0 67.0 3.0 4.5 9.0 30.0 40.0 56.0 56.0 3.0 3.0 3.0 8.0 30.0 5.5 5.5 63.0 63.0 8.55.38 7.07 7.07 25.60 25.60 35.62 35.62 5.53 8.55.38 7.07 25.60 38.46 38.46 5.35 8.30 2.00 7.60 26.00 40.50 40.50 5. 5. 2 5 4 4 67 67 2 5 24 4 67 7 2 4 9 30 55 6 96 08 All weights stated are those for the compact version; : with DN 5 flanges as standard; * DN 5, 25, 40 FB = Full bore versions of Promass I; ** DN / 4" : Nominal diameter 0 / 3" with DN / 4" flanges; *** / 6" : Nominal diameter DN / 4" with / 6" flanges; **** Promass M, high pressure version (, 5, 25), same dimensions as the standard version 7

Process Connections Promass 60 I, M, F DIN 250 Promass I Wetted parts: titanium Grade 9 Gasket material: no internal gaskets with welded process connections Promass M Flange material: SS.4404 (36L), titanium Grade 2 Gasket material: Promass F Flange material: Gasket material: O-ring in Viton (5...+0 C), EPDM (40...+60 C), Silicone (60...+0 C), Kalrez (30...+ C), FEP coated (60...+0 C) (...) SS.4404 (36L), (...80) Alloy C-22 2.4602 (N 06022) no internal gaskets with welded process connections Promass I PN 40 PN 64 PN Diameter L x L x L x DN 5 DN 5 * * * 402 438 572 578 700 708 89 827 9 23 22 26 24 28 832 34 402 438 578 578 706 708 825 832 25 25 26 29 3 32 33 36 Flanges also available with grooves to DIN 252 N (not for Promass I) : with DN 5 flanges as standard; * DN 5, 25, 40 FB = Full bore versions of Promass I Promass M, F PN 6 PN 40 PN 64 PN ti029y7 Diameter L x L x L x L x ** DN 5 ** 0 DN *** DN **** 874 28 68 22 370 404 440 550 75 840 874 28 68 6 6 8 8 24 24 24 28 400 4 470 590 724 875 28 24 26 26 28 30 400 4 470 590 740 885 28 24 26 28 32 36 : with DN 5 flanges as standard; DN only for Promass F available; **, DN 5: also available with, PN 40 flanges (L = 440 mm, x = 8 mm); *** DN : Diameter 0 with DN flanges; **** : Diameter DN with flanges Surface finish of the flanges Pressure limitations due to fluid temperature For PN 6, PN 40: DIN 2526 Form C, R a 6.3...2.5 µm For PN 64, PN : DIN 2526 Form E, R a.6...3.2 µm Pressure [bar] Promass I, M (50...+50 C) Promass F (50...+0 C) Temperature [ C] ti029y8 8

Process Connections Promass 60 I, M, F ANSI B6.5 Promass I Wetted parts: titanium Grade 9 Gasket material: no internal gaskets with welded process connections Promass M Flange material: SS.4404 (36L), titanium Grade 2 Gasket material: Promass F Flange material: Gasket material: O-ring in Viton (5...+0 C), EPDM (40...+60 C), Silicone (60...+0 C), Kalrez (30...+ C), FEP coated (60...+0 C) (...) SS.4404 (36L), (...80) Alloy C-22 2.4602 (N 06022) no internal gaskets with welded process connections Promass I Diameter Cl 50 Cl 300 Cl 600 ANSI DIN L x L x L x 3 8" 2 " 2" * " " * 2" 2 " * 2" DN 5 DN 5 * * * 402 438 572 578 700 708 89 827 9 23 22 26 24 28 402 438 572 578 700 708 89 827 9 23 22 26 24 28 402 438 578 578 706 708 825 832 22 23 25 28 29 33 3 /8": with /2" flanges as standard; * DN 5, 25, 40 FB = Full bore versions of Promass I ti029y9 Promass M, F Nennweite Cl 50 Cl 300 Cl 600 ANSI DIN L x L x L x 3 8" 2" " 2" 2" 3" 4" ** 4" 6" *** DN 5 0 DN ** DN *** 370 404 440 550 75 840 874 28 68.2.2 4.2 7.5 9. 23.9 23.9 23.9 25.4 370 404 440 550 75 840 894 28 4.2 4.2 7.5.6 22.3 28.4 3.7 3.7 400 4 490 600 742 900 58.6.6 23.9 28.7 3.8 38.2 48.4 3 /8": with /2" flanges as standard; 4" / DN : only for Promass F available; ** 4" / DN : Diameter 3"/0 with 4"/DN flanges; *** 6" / : Diameter 4" / DN with 6" / flanges Surface finish of the flanges Pressure limitations due to fluid temperature For Class 50, Class 300, Class 600: R a 3.2...6.3 µm Pressure [bar] Promass I, M (50...+50 C) Promass F (50...+0 C) Temperature [ C] ti029y 9

Process Connections Promass 60 I, M, F JIS B2238 Promass I Wetted parts: titanium Grade 9 Gasket material: no internal gaskets with welded process connections Promass M Flange material: SS.4404 (36L), titanium Grade 2 Gasket material: Promass F Wetted parts: Gasket material: O-ring in Viton (5...+0 C), EPDM (40...+60 C), Silicone (60...+0 C), Kalrez (30...+ C), FEP coated (60...+0 C) (...) SS.4404 (36L), (...80) Alloy C-22 2.4602 (N 06022) no internal gaskets with welded process connections Promass I 0K K 40K 63K Diameter L x L x L x L x DN 5 DN 5 * * * 827 28 402 438 572 578 700 708 89 827 9 23 22 26 24 28 402 438 578 578 706 708 825 827 25 25 26 27 29 30 3 32 402 438 578 578 706 708 825 832 28 28 29 30 32 36 37 40 : with DN 5 flanges as standard * DN 5, 25, 40 FB = Full bore versions of Promass I ti029y9 Promass M, F 0K K 40K 63K Diameter L x L x L x L x DN 5 0 DN ** DN *** 75 832 864 28 68 6 8 8 8 22 370 404 440 550 75 832 28 4 4 6 8 8 22 24 400 425 485 600 760 890 68 22 24 26 32 36 4 440 494 6 775 95 68 23 23 27 32 34 40 44 : with DN 5 flanges as standard; DN : only for Promass F available; ** DN : Diameter 0 with DN flanges; : Diameter DN with flanges Surface finish of the flanges For 0K, K, 40K, 63K: R a 3.2...6.3 µm Pressure limitations due to fluid temperature Pressure [bar] Promass I, M (50...+50 C) Promass F (50...+0 C) Temperature [ C] ti029y28

PVDF Process Connections Promass 60 M Wetted Parts Materials (DIN 250 / ANSI B6.5 / JIS B2238) Flange material: Gasket material: PVDF O-ring in Viton (5...+0 C), EPDM (40...+60 C), Silicone (60...+0 C), Kalrez (30...+ C), ti029y23 Diameter PN 6 / Cl 50 / 0K DIN ANSI L x DN 5 3 8" 2 " " 2" 2" 370 404 440 550 75 6 6 8 2 22 resp. 3 /8": instrument fitted with DN 5 resp. /2" flanges Caution! When using PVDF process connections Use only gaskets with a hardness Shore A 75 Use only the specified screw tightening torques (see Operating Manual) For large diameters and heavy dead weights: sensor must be supported Pressure limitations due to fluid temperature Pressure [bar] Permissible temperature range: 25...+30 C Temperature [ C] ti029y23 2

VCO Process Connections Promass 60 I, M, F Wetted Parts Materials Promass I Process connection materials: titanium Grade 2 Gasket material: no internal gaskets with welded process connections Promass M Process connection materials: Gasket materials (O-ring): SS.4404 (36L) Viton (5...+0 C), Kalrez (30...+ C), Silicone (60...+0 C), EPDM (40...+60 C Promass F Process connection materials: SS.4404 (36L) Gasket material: no internal gaskets with welded process connections ti029y42 Diameter / Connection Promass M L Promass F L 8-VCO-4 ( 2") DN 5 2-VCO-4 ( 3 4 ") 390 390 430 430 Pressure limitations due to fluid temperature Pressure [bar] ti029y44 Diameter / Connection (without nut) 2-VCO-4 ( 3 4") DN 5 2-VCO-4 ( 3 4") Promass I L 429 465 Promass I, M (50...+50 C) Promass F (50...+0 C) Temperature [ C] ti029y43 22

Sanitary Process Connections Promass 60 I, M, F Wetted Parts Materials Promass I (completely welded version) Coupling: titanium Grade 2 Promass M (connections with internal gaskets) Coupling: SS.4404 (36L) Gasket: Silicone flat gasket (60...+0 C) or EPDM (40...+60 C), FDA licensed materials Promass F (completely welded version) Coupling: SS.4404 (36L) Hygienic coupling DIN 58 / SMS 45 ti029y24 Promass M, F Diameter L Ø G DIN 85 Ø G SMS 45 DN 5 0 M 0 M 0 F DN * 367 398 434 560 7 85 792 900 28 Rd 34 x 8 " Rd 34 x 8" Rd 52 x 6" Rd 65 x 6 " Rd 78 x 6" Rd 0 x 4 " Rd 0 x 4" Rd 30 x 4 " Rd 40 x 6 " Rd 40 x 6" Rd 40 x 6" Rd 60 x 6 " Rd 70 x 6" Rd 98 x 6" Rd 98 x 6" Rd 32 x 6 " : with DN 5 connections as standard; 3A version with Ra 0.8 µm available; * DN only for Promass F available Promass I Diameter L DIN 85 L SMS 45 Ø G DIN 85 Ø G SMS 45 DN 5 DN 5 DN 5 ** ** ** 426 427 462 463 602 603 736 73 855 856 427 463 603 736 738 857 858 Rd 28 x 8" Rd 34 x 8 " Rd 28 x 8" Rd 34 x 8" Rd 34 x 8" Rd 52 x 6" Rd 52 x 6 " Rd 65 x 6" Rd 65 x 6" Rd 78 x 6 " Rd 40 x 6 " Rd 40 x 6" Rd 40 x 6" Rd 40 x 6 " Rd 60 x 6" Rd 60 x 6" Rd 70 x 6 " ** DN 5, 25, 40 FB = Full bore versions of Promass I 3A version with Ra 0.8 µm as standard Pressure limitations due to fluid temperature Pressure [bar] Promass I, M (50...+50 C) Promass F (50...+0 C) Temperature [ C] ti029y25 23

Sanitary Process Connections Promass 60 I, M, F Wetted Parts Materials Promass I (completely welded version) Tri-Clamp: titanium Grade 2 Promass M (connections with internal gaskets) Tri-Clamp: SS.4404 (36L) Gasket: Silicone flat gasket (60...+0 C) or EPDM (40...+60 C), FDA licensed materials Promass F (completely welded version) Tri-Clamp: SS.4404 (36L) Tri-Clamp ti029y26 Promass M, F Diameter Clamp L Ø G Ø D DIN ANSI DN 5 DN 5 0 M 0 F DN * 3 8 " 3 8" 2" 2 " " 2" 2" 3" 3" 4" 2 " " 2" " " 2" 2" 2" 3" 4" 367 367 398 398 434 560 7 80 900 28 25.0 50.4 25.0 50.4 50.4 50.4 63.9 90.9 90.9 8.9 9.5 22. 9.5 22. 22. 34.8 47.5 72.9 72.9 97.4 3 / 8" and /2": with " connections as standard; 3A version with Ra 0.8 µm available; * DN / 4" only for Promass F available Promass I Diameter Clamp L Ø G Ø D DIN ANSI DN 5 DN 5 DN 5 DN 5 ** ** ** 3 8" 3 8" 3 8 " 2" 2" 2 " 2" " " 2" 2 " 2" 2" 3 4" " 2" 3 4" " 3 4" " " 2" 2 " 2" 426 426 427 462 462 463 602 603 730 73 849 850 25.0 25.0 50.4 25.0 25.0 50.4 25.0 50.4 50.4 50.4 50.4 63.9 9.5 6.0 22. 9.5 6.0 22. 6.0 22. 22. 34.8 34.8 47.5 ** DN 5, 25, 40 FB = Full bore versions of Promass I 3A version with Ra 0.8 µm or Ra 0.4 µm as standard Pressure limitations due to fluid temperature The material load limit is exclusively determined by the material properties of the Tri-Clamp used. This clamp is not included in the shipment. 24

Dimensions Process Connections Compact version Promass 60 M (high pressure) ti029y05 Process connection N L L L2 G 3 8" without with connectors L3 VCO with 2 "-SWAGELOK L4 2"- NPT L5 3 8"- NPT DN 5 24 24 34 256 286 30 304 334 378 355.8 385.8 429.8 366.4 396.4 440.4 370 400 444 355.8 385.8 429.8 all dimensions in Diameter B B di Weight [kg] DN 5 262.5 264.5 268.5 3.0 4.5 9.0 4.93 7.75 0. 2 5 Remote version max. m ti029y06 25

Pressure Limitations Promass 60 M (high pressure) Wetted Parts Materials Measuring tube: titanium Grade 9 Connectors: SS.4404 (36L) Fittings: SS.440 (36) Gaskets: O-rings in Viton (5...+0 C), Silicone (60...+0 C) Couplings and connectors optimized for CNG (Compressed Natural Gas) applications. Pressure limitations due to fluid temperature Pressure [bar] / 2 " - NPT Temperature [ C] Connectors, G 3 / 8 ", VCO with / 2 " SWAGELOK, 3 / 8 " - NPT Pressure [bar] ti029y3 Temperature [ C] 26

Dimensions Promass 60 M (without Process Connections) O-ring O-ring O-ring ti029y49 DIN Diameter DN ANSI L Dimensions Coupling Minimum screw depth J K Screws M Torque Lubricated thread Depth b [Nm] yes/no Diam. O-ring Inside * DN 5 DN 5* * 0 3 8" 3 8" 2 " 2" " " 2" 2" 3" 256 256 286 286 30 30 40 544 644 27 27 35 35 40 40 53 73 02 54 54 56 56 62 62 80 94 28 6x M8 6x M8 6x M8 6x M8 6x M8 6x M8 8x M0 8x M0 2 x M 2 2 2 2 2 2 2 5 5 8 0 0 0 0 0 0 3 3 5 30.0 9.3 30.0 9.3 30.0 9.3 60.0 60.0.0 no yes no yes no yes no yes yes 2.62 2.62 2.62 2.62 2.62 2.62 2.62 2.62 3.53 2.89 2.89 29.82 29.82 34.60 34.60 47.30 67.95 94.84 * High pressure version; Permissible thread: A4-80; Lubricant: Molykote P37 27

Dimensions Purge Connection Pressure vessel control Promass Sensor A I M F ti029y48 Diameter Promass A Promass I Promass M Promass F Connection DIN ANSI L H L H L H L H G DN DN 2 DN 4 DN 5 DN 5 * * * 0 DN 24" 2" 8 " 3 8" 3 8 " 2" " " 2" 2" 2" 3" 4" 92.0 30.0 92.5 87.0 87.0 97. 6 79 79 48 48 96 96 254 78.5 78.5 78.5 78.5 78.5 90.85 90.85 05.25 85 0 55 44.0 46.5 50.0 59.0 67.5 8.5 08 0 30 55 226 280 342 47 47 47 52 64 86 2" NPT 2" NPT 2 " NPT 2" NPT 2 " NPT 2" NPT 2" NPT 2 " NPT 2" NPT 2" NPT 2 " NPT 2" NPT 2 " NPT * DN 5, 25, 40 FB = Full bore versions of Promass I; 28

Technical Data Application Instrument name Instrument function Flow measuring system Promass 60 (HART) Mass and volumetric flow measurement of liquids and gases in closed piping. Function and system design Measuring principle Measuring system Mass flow measurement according to the Coriolis measuring principle (see page 3) Instrument family Promass 60 consisting of: Transmitter: Promass 60 Sensors: Promass A, I, M and F Promass A Promass I DN, 2, 4 and DN 2, 4 high pressure version. Single tube system in SS or Alloy C-22, 5, 25, 40, 50 (completely welded version) Straight single tube system in titanium DN 5 FB, FB, FB : Full bore versions of Promass I with a higher full scale value (see table below) Promass F, 5, 25, 40, 50, 80, (completely welded version) Two slightly curved measuring tubes in SS (...) or Alloy C-22 (...80) Promass M, 5, 25, 40, 50, 80 (two straight measuring tubes in titanium) Containment vessel up to bar.,5, 25 high pressure version for operating pressures up to 350 bar Two versions are available: Compact version Remote version (max. m) Input variables Measured variables Mass flow rate (is proportional to the phase difference of two sensors on the measuring tubes which detect differences in its oscillation) Fluid density (is proportional to the resonance frequency of the measuring tubes) Fluid temperature (is measured with temperature sensors) Measuring range DN Range of full scale values Liquid Gas m min (L)... m max (L) m min (G)... m max (G) 2 4 8 5 5* 25 25* 40 40* 50 80 0....0 kg/h 0...0 kg/h 0...450.0 kg/h 0... 2.0 t/h 0... 6.5 t/h 0... 8.0 t/h 0... 8.0 t/h 0... 45.0 t/h 0... 45.0 t/h 0... 70.0 t/h 0... 70.0 t/h 0...80.0 t/h 0...350.0 t/h The full scale depends on the density of the gas. The full scale value can be determined with the following formula: mmax( G ) mmax( L ) ρ ( G) m max( G) m = ρ max( L) ( G) x 6. = Full scale value gas [t/h] = Full scale value liquid [t/h] (value from table) = gas density [kg/m 3 ] (at operating conditions) x = constant [kg/m 3 ] Promass A: x = Promass I, M, F: x = * DN 5, 25, 40 FB = Full bore version of Promass I (continued on next page) 29

Technical Data Input variables (continued) Measuring range (continued) Example for calculating a gas full scale value: Sensor: Promass F x = Nominal Diameter 70.0 t/h (full scale value from table on page 29) Gas: Air with a density of 60.3 kg/m 3 (at C and 50 bar) mmax( L) ρ( G) 70. 0 60. 3 mmax( G) = = = 26. 4 t/h x 6. 6. Operable flow range Auxiliary input up to 0 :. This enables totalizer values to be accurately determined. U = 3...30 V DC, Ri =.8 kω Configurable for: zero point adjustment, positive zero return, totalizer reset. Output variables Output signal Current output (with HART protocol) 0/4... ma; RL < 700 Ω (DIP switches) or 4... ma, RL 250 Ω (HART) Time constant: approx. s (DIP switches) or freely selectable (HART) Full scale value: 8 values selectable (DIP switches) or freely selectable (HART) Temperature coefficient: typ. 0.0% o.f.s./ C o.f.s. = of full scale Pulse output Open Collector: 0...400 Hz (fmax = 500 Hz) Umax = 30 V, Imax = 250 ma Pulse value: 8 values selectable (DIP switch) or freely selectable (HART) Pulse width: max. 0 s (DIP switch) or freely selectable (HART) Status output Open Collector: Umax = 30 V, Imax = 250 ma configurable for error messages or flow direction recognition Signal on alarm The following applies until the fault has been cleared: Current output: is set to a defined value (0... ma 0 ma; 4... ma 2 ma) Pulse output: no pulses Status output: Output is open, if configured for error, (i.e. the Open Collector is not conducting). Load See specifications Output signal Creep suppression DIP switch configuration: Switch on point at v 0.02 m/s (for water) Switch off point at v 0.04 m/s (for water) HART configuration: Freely selectable switching points (hysteresis: 50%) Accuracy Reference conditions Error limits based on ISO / DIS 63:...30 C; 2...4 bar Calibration facilities based on national standards Zero point calibrated under operating conditions Field density calibration carried out 30

Technical Data Accuracy (continued) Measured error Mass flow rate (liquids): Promass A, M, F ± 0.5% ± [(zero stability / flow rate) x ]% of rate I ± 0.% ± [(zero stability / flow rate) x ]% of rate Mass flow rate (gas): Promass A, I, M, F ± 0.50% ± [(zero stability / flow rate) x ]% of rate Volume flow rate (liquids): Promass A, M ± 0.25% ± [(zero stability / flow rate) x ]% of rate I ± 0.50% ± [(zero stability / flow rate) x ]% of rate F ± 0.% ± [(zero stability / flow rate) x ]% of rate Zero stability see table below Note! The values below refer to the pulse/frequency output. Additional measuring error of the current output: typ. ± 0 µa. Diameter DN DN 2 DN 4 DN 5 DN 5* * * 0 DN Max. full scale [kg/h] or [l/h] Zero stability Promass A, M, F [kg/h] or [l/h] Zero stability Promass I [kg/h] or [l/h] 450 00 6500 8000 8000 45000 45000 70000 70000 80000 350000 0.000 0.0050 0.0225 0.0 0.3250 0.90 2.25 3.50 9.00 4.00 0.0 0.650.800.800 4.500 4.500 7.000 7.000 * DN 5, 25, 40 FB = Full bore versions of Promass I Example for calculating the measuring error: Promass F ± 0.5% ± [(zero stability/flow rate) x ]% of rate ; Flow rate: 3.6 t/h = 3600 kg/h Measuring error ± 0.5% ± 0.9 kg h % = ± 0.75% 3600 kg h Repeatability Mass flow rate (liquids): Promass A, I, M, F ± 0.05% ± [ /2 x (zero stability / flow rate) x ]% of rate Mass flow rate (gas): Promass A, I, M, F ± 0.25% ± [ /2 x (zero stability / flow rate) x ]% of rate Volume flow rate (liquids): Promass A, M ± 0.0% ± [ /2 x (zero stability / flow rate) x ]% of rate I ± 0.% ± [ /2 x (zero stability / flow rate) x ]% of rate F ± 0.05% ± [ /2 x (zero stability / flow rate) x ]% of rate Zero stability see table above Example for calculating the repeatability: Promass F F ± 0.05% ± [(zero stability / flow rate) x ]% of rate ; Flow rate: 3.6 t/h = 3600 kg/h Repeatability ± 0.05% ± 0.9 kg h /2 % = ± 0.0625% 3600 kg h 3

Technical Data Accuracy (continued) Process effects Process temperature effect: The below value represents the zero point error due to changing process temperature away from temperature at which a zero point adjustment was carried out: Promass A, I, M, F typical = ± 0,0002% of full scale / C Process pressure effect: The below defined values represent the effect on accuracy of mass flow due to changing process pressure away from calibration pressure (values in % of rate / bar). DN Promass A flow rate % o.r.** / bar Promass I flow rate % o.r.** / bar Promass M flow rate % o.r.** / bar Promass MP flow rate % o.r.** / bar Promass F flow rate % o.r.** / bar 2 4 8 5 5 * 25 25 * 40 40 * 50 80 none none none 0.006 0.004 0.006 0.006 none none 0.006 0.006 0.009 0.008 0.009 0.005 none none 0.006 0.005 0.003 none none none 0.003 0.008 0.009 0.02 * DN 5, 25, 40 FB = Promass I mit vollem Nennweitenquerschnitt ** o.r. = of rate Operating conditions Installation conditions Installation instructions Inlet and outlet sections Connection cable length Orientation: vertical or horizontal. Restrictions on installation and other recommendations: see page 9 Installation site is independent of inlet and outlet sections. Remote version: max. meters Ambient conditions Ambient temperature Transmitter and Sensor: 25...+60 C (Version with enhanced climate resistance: 40...+60 C) Depending on the fluid temperature, certain installation positions are to be observed to ensure that the permitted ambient temperature range for the transmitter is not exceeded (see page ). An all-weather cover should be used to protect the housing from direct sunlight when mounting in the open. This is especially important in warmer climates and with high ambient temperatures. If the ambient temperature is below 25 C, it is not recommended to use a version with display. Storage temperature Degree of protection (EN 60529) 40...+80 C Transmitter: IP 67; NEMA 4X Sensor: IP 67; NEMA 4X Shock resistance according to IEC 68-2-3 Vibration resistance up to g, 0...50 Hz according to IEC 68-2-6 Electromagnetic compatibility (EMC) Acc. to EN 5008 Part and 2 / EN 50082 Part and 2 as well as to NAMUR recommendations 32

Technical Data Operating conditions (continued) Process conditions Fluid temperature Sensor Promass A 50...+0 C Promass I 50...+50 C Promass M 50...+50 C Promass F 50...+0 C Gaskets Viton EPDM Silicone Kalrez FEP coated (5 +0 C) (40 +60 C) (60 +0 C) (30 + C) (60 +0 C) Nominal pressure Material load curves (p-t- diagrams): s. page 6, 8 ff. Promass A Fittings: max. 60 bar (standard version) max. 400 bar (high pressure version) Flanges: DIN PN 40 ANSI Cl 50, Cl 300 JIS 0K Containment vessel: 25 bar resp. 375 psi Promass I Flanges: DIN PN 40... ANSI Cl 50, Cl 300, Cl 600 JIS 0K, K, 40K, 63K Containment vessel: 25 bar (optional 40 bar) resp. 375 psi (optional 600 psi) Promass M Flanges: DIN PN 40... ANSI Cl 50, Cl 300, Cl 600 JIS 0K, K, 40K, 63K Containment vessel: 40 bar (optional bar) resp. 600 psi (optional 500 psi) Promass M (High pressure version) Measuring tubes, connector, fittings: max. 350 bar Containment vessel: bar resp. 500 psi Promass F Flanges: DIN PN 6... ANSI Cl 50, Cl 300, Cl 600 JIS 0K, K, 40K, 63K Containment vessel:...80: DN :...50: 25 bar resp. 375 psi 6 bar resp. 250 psi optional 40 bar resp.600 psi Pressure loss dependent on nominal diameter and sensor type (see page 2, 3) 33