Infrared Thermometer Model CA879

Similar documents
HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

InfraRed Thermometer with Laser Pointer

INFRARED THERMOMETER TM0819

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Dual laser + type K thermometer INFRARED THERMOMETER

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

INFRARED THERMOMETER Model : TM-959

The Fluke 66 and 68 Infrared Thermometers

566/568. Infrared Thermometers. Getting Started

Infrared Hand-Held Thermometers

IR/Thermistor Pen. Instruction Manual

Instruction Manual SEFRAM Thermal Camera

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

Manual Dew point scanner PCE-DPT 1

Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.

INSTRUCTION MANUAL Fax: (503)

Noncontact Thermometer

VIBRATION METER. Instruction Manual.

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

High Accuracy High Speed in Your Process

Infrared Hand-Held Thermometers

Introduction Cautions

DIGITAL THERMOMETER OPERATOR S MANUAL

INSTRUCTION MANUAL DTH Fax: (503)

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Acceleration/Velocity/Displacement VIBRATION METER

Operator's Manual. optris BR 400. Calibration source

TSC JR 2 Manual SERIES 4B, 5B & 6B

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

63/66/68. Infrared Thermometers. Users Manual

473 Dew Point Hygrometer

for XPS surface analysis

Thermo Scientific K-Alpha + XPS Spectrometer. Fast, powerful and accessible chemical analysis for surface and thin film characterization

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Introduction to Fourier Transform Infrared Spectroscopy

473-SHX Dew Point Mirror

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

473 Dew Point Hygrometer

INF195 Infrared Thermometer

VIBRATION TACHOMETER OPERATION MANUAL. 3 in 1. Model : VT Your purchase of this

IR and contact thermometers

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

optris LaserSight Operators manual

Rapid RH Portable ph Meter. User's Manual

INSTRUCTION MANUAL RS 51 & RS 52 DIGITAL THERMOMETER

Introduction to Fourier Transform Infrared Spectroscopy

IR-712 IR-712-EUR 12:1 Infrared Thermometer. IR-720 IR-720-EUR 20:1 Infrared Thermometer. IR-730 IR-730-EUR 30:1 Infrared Thermometer.

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

THERMOFOCUS, a technological innovation

Mini Environmental Quality Meter

Training Guide. Coastal Environmental Systems, Inc.

THERMYS 150. Advanced field reference thermometer / temperature calibrator

Designed to go where you work

IR-712 IR-720 IR-730

ea980r Digital Anemometer User Manual

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

Part Number Range Accuracy Printing WP * Probe Special User LDC with Page Logging included Feature Cal Backlight

Infrared Thermometer Calibration A Complete Guide

BUREAU OF INDIAN STANDARDS. Draft Indian Standard GUIDELINES FOR INFRARED THERMOGRAPHY INSPECTION OF ELECTRICAL INSTALLATIONS ICS 19.

One-hand ph/temperature measuring instrument

User Manual VX4750 Function Generator Module

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

MODEL: MO Digital DC Milliohm Meter OPERATING INSTRUCTION

Vet Photometer DP 700 Operating Manual. Version V5.9

Operating Instructions for Digital Manometer. Model: MAN-SD

E THERMADATA LOGGER Humidity & temperature recording meter

1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration

OPERATING INSTRUCTIONS

Analog - Digital multimeters

(i) Show that the energy of a single photon is about 3 x J.

Instruction Manual HI Refractometer for Invert Sugar Measurements

XR Analog Clock - Manual Setting Model Troubleshooting Guide

Digital Fluxmeter CYHT700SP

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Instruction Manual HI Refractometer for Sodium Chloride Measurements

CLOCKS MARATHON WATCH COMPANY LTD.

Heat stress index. Dewpoint. pressure. altitude

of mass spectrometry

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

PG-100 HANDY MANOMETER COPAL ELECTRONICS FEATURES MODEL NUMBER DESIGNATION P G G P. marking Compatible with EMC directive

Infrared Thermometer Model: and

TM360 TEMP-SEEKER PRECISION THERMO-PSYCHROMETER OPERATION MANUAL

CR10TCR THERMOCOUPLE REFERENCE

Non contact temperature measurement

Transcription:

Infrared Thermometer Model CA879 The Infrared Thermometer Model CA879 is a non-contact temperature measuring instrument. It incorporates a laser target feature for precision measurement To measure the temperature of an object, simply point the gun at the surface of the object and the temperature will appear on the digital display. The thermometer has an automatic shut-off feature. Shut-off will occur approximately 10 seconds after the trigger is released. All objects whose temperature is higher than absolute zero (-273.15 K) emit infrared energy. This energy radiates in all directions at the speed of light. When the gun is pointed at an object, the probe s lens senses this energy and focuses it onto an infrared detector comprised of a thermocouple stack. The detector produces a voltage signal proportional to the amount of energy received, and therefore proportional to the object s temperature. Certain objects emit infrared energy, but also reflect it. Unlike matt surfaces, shiny or highlypolished surfaces tend to reflect energy. This reflection is represented by a factor called emissivity, which may vary from 0.1 for a highly reflective object to 1 for a black object. In the case of the Infrared Thermometer Model CA879, the emissivity is preset at 0.95, the most frequent value, enabling approximately 90% of all applications to be covered. Technical Assistance (800) 343-1391 www.aemc.com 1 of 5

Features Easy one-hand operation Non-contact infrared sensor Laser guide for precise aim 12:1 Field of Vision Ratio Measures temperature in F and C Fixed 0.95 emissivity Auto-HOLD function 2000-count backlit LCD Applications Electrical troubleshooting Food safety and processing Automotive repair and maintenance Marine maintenance and repairs Test faulty motor winding insulation Test overheated high voltage transformers Test terminals on circuit breaker panels Perform HVAC energy audits Specifications Specifications MODEL ELECTRICAL CA879 Measuring Range -58 to 1022 F (-50 to 550 C) Resolution Polarity 0.1 F from -58 to 200 F, 1 F beyond this range 0.1 C from -50 to 200 C, 1 C beyond this range Automatic (minus only) Accuracy ±1.5% of the reading ±4 F of -4 to +1022 F / ±9 F of -58 to -4 F ±1.5% of the reading ±2 C of -20 to +550 C / ±5 C of -50 to -20 C Emissivity Preset at 0.95 Spectral Response 6 to 14µm Response Time Laser Target Power Source MECHANICAL Dimensions Weight ENVIRONMENTAL Operating: Temperature Humidity Storage: Temperature Humidity SAFETY 400ms 1mW (670nm type) One 9V Alkaline battery included (6LR61 or 6LF22) 9.05 x 3.93 x 2.20" (230 x 100 x 56mm) 290g 32 to 122 F (0 to 50 C) 10 to 90% RH -4 to 140 F (-20 to 60 C) without battery < 80% RH Electromagnetic Compatibility EN 50081-1 Ed. 1992: EN 55022 EN 50082-1 Ed. 1997: EN 55024 Field of Vision Ratio Technical Assistance (800) 343-1391 www.aemc.com 2 of 5

Construction 4 11 5 8 12 SCAN = 0.95 9 1 10 HOLD C F 13 14 15 6 2 C F 7 3 1. LCD Display 2. Temperature selection and backlight buttons 3. Laser target button 4. Laser pointer beam 5. IR Sensor 6. Measurement trigger 7. Battery cover 8. Measurement indication 9. Data hold indication 10. Low battery indication 11. Laser beam ON indication 12. Fixed emissivity ε (0.95) 13. Digital temperature indication 14. Degrees in Celsius 15. Degrees in Fahrenheit Technical Assistance (800) 343-1391 www.aemc.com 3 of 5

Accessories Model CA879 includes soft carrying case and user manual. ordering information catalog no. Infrared Thermometer Model CA879...Cat. #2121.37 Technical Assistance (800) 343-1391 www.aemc.com 4 of 5

Contact Us United States & Canada: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 200 Foxborough Blvd. Foxborough, MA 02035 USA (508) 698-2115 Fax (508) 698-2118 www.aemc.com Customer Support for placing an order, obtaining price & delivery: customerservice@aemc.com Sales Department for general sales information: sales@aemc.com Repair and Calibration Service for information on repair & calibration, obtaining a user manual: repair@aemc.com Technical and Product Application Support for technical and application support: techinfo@aemc.com Webmaster for information regarding www.aemc.com: webmaster@aemc.com South America, Central America, Mexico, Caribbean, Australia & New Zealand: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA (978) 526-7667 Fax (978) 526-7605 export@aemc.com www.aemc.com All other countries: Chauvin Arnoux SCA 190, rue Championnet 75876 Paris Cedex 18, France 33 1 44 85 45 28 Fax 33 1 46 27 73 89 info@chauvin-arnoux.com www.chauvin-arnoux.com Technical Assistance (800) 343-1391 www.aemc.com 5 of 5