Determination of releasable 2,4,6-trichloroanisole in wine by cork stoppers (Resolution OIV-Oeno 296/2009)

Similar documents
Method of determination of phtalates in spirituous beverages by gaschromatography/mass

Anethole. Gas chromatograhpy determination of trans-anethole in Spirit srinks of viti-vinicultural origin

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

637. Thiamethoxam. HPLC method

Determination of Volatile Substances Proof of Food Adulteration

GAFTI Analytical method for ISO/TS 16179:2012 Detection and Determination of Organotin Compounds in Footwear and Apparel Materials by GC-MS

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

GC/MS Application Note

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION

Sulfotepp impurities in Chlorpyrifos EC formulations

DIQUAT DIBROMIDE. The Determination of Ethylene Dibromide in Diquat Dibromide and Diquat Dibromide / Paraquat Dichloride SL Formulations

ENVIRONMENTAL analysis

Application. Gas Chromatography February Introduction

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Quantification of total nitrogen according to the Dumas method (Musts and Wines) (Resolution Oeno 13/2002)

STANDARD OPERATING PROCEDURES SOP: 1826 PAGE: 1 of 18 REV: 0.0 DATE: 03/30/95 ANALYSIS OF METHYL PARATHION IN WIPE SAMPLES BY GC/MS

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

British American Tobacco Group Research & Development. Method - Determination of phenols in mainstream cigarette smoke

Report AFK0242/18 TABLE OF CONTENTS

Standard Test Method for Determination of Trace Thiophene in Refined Benzene by Gas Chromatography 1

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

STANDARD OPERATING PROCEDURES

METHOD 8111 HALOETHERS BY GAS CHROMATOGRAPHY

G a s C h r o m a t o g r a p h y Determination of Ethanol in Wine by Head-Space Gas Chromatography

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID)

Method for the determination of dimethyl sulfate

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Draft Method proposal: determination of glucoheptonic acid (HGA) in fertilizers.

anthracene Figure 1: Structures of Selected Polyaromatic Hydrocarbons (PAHs)

Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

The analysis of organic acid content of additives, premix, feed, and water.

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

OPTIMISATION OF SOLID PHASE MICROEXTRACTION (SPME) CONDITIONS FOR HEADSPACE ANALYSIS OF ORGANOPHOSPHATE PESTICIDES IN WHOLE BLOOD

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

Gas Chromatography (GC)

Solid Phase Microextraction of Cyanogen Chloride and Other Volatile Organic Compounds in Drinking Water with Fast Analysis by GC-TOFMS

BUTYL ALCOHOL in urine by GC-FID Code GC05510

Method - Determination of aromatic amines in mainstream cigarette smoke

Automated Sample Preparation of Headspace Standards Using the Agilent 7696 WorkBench

IMPCA METHANOL REFERENCE SPECIFICATIONS

ACETONE IN URINE BY GC/MS Headspace Code GC10110

Benzoylecgonine in Urine by SAMHSA GC/MS

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

TRICHLOROETHYLENE IN URINE BY GC/MS Headspace Code GC16110

PAL SPME Arrow The Better SPME

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Date 10/22/97 Page 1 Revision 4.1 OKLAHOMA DEPARTMENT OF ENVIRONMENTAL QUALITY METHODS 8000/8100 (MODIFIED) DIESEL RANGE ORGANICS (DRO)

DETERMINATION OF GAMMA-HYDROXYBUTYRATE (GHB) BY HEADSPACE-GC/MS (FID) IN FORENSIC SAMPLES

GB/T / ISO :2006

METHYLETHYLKETONE (M.E.K.) IN URINE BY GC/MS in head space Code GC10010

The Nitrofurantoin Capsules Revision Bulletin supersedes the currently official monograph.

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

METROLOGY IN CHEMISTRY MEETING. AZIZ MUKOTA Chemistry Laboratory Uganda National Bureau of Standards

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 7(2),

Annex 2 Formaldehyde

H 3 CO H 3 CO S CH 3

U.S. EPA Method 8270 for multicomponent analyte determination

RESOLUTION OIV-OENO CONSIDERING the work of the Specifications of Oenological Products Expert Group,

Dynamic headspace (DHS) technique: set-up and parameter control for GC/MS analysis of odorant formulations

NCASI METHOD CI/SG/PULP-94.02

1-(2-METHOXYPHENYL)PIPERAZINE Latest revision: June 27, 2005

Spectra Library Electron Capture Negative Ion (ECNI) Mass Spectra of Selected Polybrominated Diphenyl Ethers (PBDEs)

METHANOL REFERENCE SPECIFICATIONS

CALIBRATION OF GC/MS METHOD AND VALIDATION OF THE MODIFIED SAMPLE PREPARATION FOR DETERMINATION OF POLYCYCLIC AROMATIC HYDROCARBONS

PAL SPME Arrow The Better SPME

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

METHYLISOBUTYLKETONE (4-methyl-2 pentanone) IN URINE BY GC/MS Headspace Code GC10510

Methods for the determination of vinyl chloride

CIPAC. CIPAC Free relevant impurities methods:

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

APPENDIX A TO PART 136 METHODS FOR ORGANIC CHEMICAL ANALYSIS OF MUNICIPAL AND INDUSTRIAL WASTEWATER METHOD 609 NITROAROMATICS AND ISOPHORONE

Application of Solid Phase Micro Extraction in Environmental Analysis

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Method for the determination of 1,3-butadiene

Odours from Food Packagingan Analytical Challenge?

Analysis of BTEX in Natural Water with SPME

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

Measuring ochratoxine A in wine after going through an immunoaffinity column and HLPC with fluorescence detection

IMPCA METHANOL REFERENCE SPECIFICATIONS

Methods of Analysis of Polychlorinated Biphenyl Congeners Using an Application-Specific Capillary GC Column

METHOD 7199 DETERMINATION OF HEXAVALENT CHROMIUM IN DRINKING WATER, GROUNDWATER AND INDUSTRIAL WASTEWATER EFFLUENTS BY ION CHROMATOGRAPHY

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

SPME-GC-MS/MS for Identification and Quantification of Migration Contaminants in Paperboard Food Packaging

AppNote 1/2004. Use of a Mass Spectral Based Chemical Sensor to Discriminate Food and Beverage Samples: Olive Oils and Wine as Examples KEYWORDS

ChromTech options for PAL systems

GC-CI-MS analysis of TMS derivatives

Transcription:

Method OIV-MA-AS315-16 Type IV method Determination of releasable in wine by cork stoppers (Resolution OIV-Oeno 296/2009) 1 SCOPE: The method of determination of releasable (TCA) by cork stoppers measures the quantity of TCA released by a sample of cork stoppers macerated in a aqueous-alcoholic solution. The aim of this method is to evaluate the risk of releasing by the lot of analyzed cork stoppers and to provide a method for controlling the quality of cork stoppers. 2 PRINCIPLE The method aims to simulate migration phenomena susceptible of being produced between the cork stopper and wine in bottles. Cork stoppers are macerated in a wine or a aqueous-alcoholic solution, until a balance is obtained. The TCA of the head space is sampled from an appropriate part of the macerate by the solid-phase micro-extraction technique (SPME), then analyzed by gas chromatography, with detection by mass spectrometer (or by electron-capture detector). 3 REAGENTS AND PRODUCTS 3.1 White wine with an alcoholic strength ranging between 10 and 12 % vol. (It can be replaced by an aqueous-alcoholic solution with an alcoholic strength of 12 % vol). The wine and/or the aqueous-alcoholic solution must be free of TCA. 3.2 Sodium chloride 99.5 % 3.3 (TCA)-d 5 purity 98% for GC/MS; 2,6- dibromoanisole or 2,3,6-trichloroanisole purity 99 % for GC/ECD 3.4 (TCA) purity 99.0% 3.5 Absolute ethanol 3.6 Pure de-ionised water void of TCA (Standard EN ISO 3696) 3.7 Aqueous-alcoholic solution at 12 % vol. Prepared using absolute ethanol (3.5) and de-ionised water void of TCA (3.6). 3.8 Internal standard stock solution (500 mg/l) OIV-MA-AS315-16 : R2009 1

Add either 0.050 g of -d 5 (or 2,6-dibromoanisole or 2,3,6- trichloroanisole (3.3) to approximately 60 ml of absolute ethanol (3.5). After dissolution, adjust the volume to 100 ml with absolute ethanol (3.5). It can be kept in a glass bottle with a metallic or glasscover. 3.9 Intermediate solution of internal standard (5.0 mg/l) Add 1 ml of a solution of either -d 5 (or 2,6- dibromoanisole or 2,3,6-trichloroanisole) at 500 mg/l (3.8) to approximately 60 ml of absolute ethanol (3.5). Adjust the volume to 100 ml with absolute ethanol (3.5). It can be kept in a glass bottle with a metallic or glass cover. 3.10 Internal standard solution (2.0 µg/l) Add 40 µl of a solution of either -d 5 (or 2,6- dibromoanisole or 2,3,6 trichloroanisole) at 5.0 mg/l (3.9) to approximately 60 ml of absolute ethanol (3.5). Adjust the volume to 100 ml with absolute ethanol (3.5). It can be kept at an ambient temperature in a glass bottle with a metallic or glass cover. 3.11 Stock solution of TCA standard (40 mg/l) Add 0.020g of to approximately 400 ml of absolute ethanol (3.5). Following dissolution, adjust volume to 500 ml with absolute ethanol (3.5). 3.12 Intermediate solution A of TCA standard (80 μg/l) Add 1 ml of solution at 40 mg/l (3.11) to approximately 400 ml of absolute ethanol (3.5). Following dissolution, adjust volume to 500 ml with absolute ethanol (3.5). 3.13 Intermediate solution B of TCA standard (160 ng/l) Add 1 ml of solution at 80 μg/l (3.12) to approximately 400 ml of pure de-ionised water (3.6). Following dissolution, adjust the volume to 500 ml with pure de-ionised water (3.6) 3.14 Use the standard-addition technique to make up a range of standard solutions of TCA. Standard solutions in the range from 0.5 ng/l to 50 ng/l can be used, by making additions with a solution of at 160 ng/l (3.13) to 6 ml of absolute ethanol (3.5). Following dissolution, adjust volume to 50 ml with pure de-ionised water (3.6) The calibration curve obtained should be evaluated regularly and in any case whenever there is a major change in the GC/MS or GC/ECD systems. 3.15 Carrier gas: Helium, chromatographic purity ( 99.9990 %) OIV-MA-AS315-16 : R2009 2

4. APPARATUS 4.1 Laboratory glassware 4.1.1 Graduated 100-mL flask 4.1.2 100-µL microsyringe 4.1.3 Wide-neck glass jar of a capacity adapted to the sample size, closed with a glass or metallic stopper or a material which does not bind TCA. 4.1.4 20-mL glass sample bottle closed with a perforated capsule and a liner with one side Teflon-coated. 4.2 Solid-phase microextraction system (SPME) with a fiber coated with a polydimethylsiloxane film 100 µm thick 4.3 Heating system for sample bottle (4.1.4) 4.4 Stirring system for sample bottle (4.1.4) 4.5 Gas chromatograph equipped with a "split-splitless" injector and a mass spectrometer detector (MS) or an electron-capture detector (ECD) 4.6 Data-acquisition system 4.7 If required, an automatic sampling and injection system operating with an SPME system 4.8 Capillary column coated with an apolar stationary phase, of the phenylmethylpolysiloxane type (e.g.: 5 % phenyl methylpolysiloxane, 30 m x 0,25 mm x 0,25 µm film thickness or equivalent.) 5. SAMPLE PREPARATION The corks are placed whole in a glass closed container. The container capacity (4.1.3), the same as the quantity of wine or aqueous-alcoholic solution (3.1 or 3.7), must be chosen in accordance to the sample size while ensuring that the corks are completely covered and immersed in the maceration container. Example 1: 20 corks (45x24) mm, in a 1 L container; Example 2: 50 corks (45x24) mm, in a 2 L container. Most of the TCA released during maceration of the groups of stoppers is generally derived from a very low percentage of these stoppers. In order to obtain the best representation of a batch of stoppers, a number of appropriate analyses according to sampling rules and risk with regard to wine contamination should be carried out. 6. OPERATING METHOD 6.1 Extraction OIV-MA-AS315-16 : R2009 3

After macerating at ambient temperature for (24 2) hours under laboratory ambient temperature conditions, the maceration is homogenized by inversion. A part of the aliquot of the 10ml maceration solution (5) is transferred to a glass sample bottle (4.1.4) To increase extraction efficiency and subsequent sensitivity of the method, a quantity of approximately 1 g of sodium chloride (3.2) can be added. 50 µl of the internal standard solution at 2.0 µg/l (3.10) are immediately added, then the bottle is closed using a perforated metal capsule fitted with a silicone / Tefloncoated liner. The capsule is crimped. The contents of the bottle are homogenized for 10 minutes by mixing using a stirring system (4.4) or by using an automatic system (4.7). The bottle containing the sample is placed in the heating system (4.3) set to 35 C ± 2 C, with stirring (4.4). The extraction of the headspace is carried out using the SPME system (4.2) for at least 15 minutes. 6.2 Analysis The fiber is then desorbed at 260 C for at least 2 minutes in the injector of a gas chromatograph, in splitless mode (4.5). The separation is carried out using a capillary column with a non-polar stationary phase (4.8). The carrier gas is helium with a constant flow of 1 ml/min. A temperature program from 35 C (for 3 min) to 265 C (at 15 C/min) is given as an example. 6.3 Detection and quantification Detection is carried out by mass spectrometry with a selection of specific ions for the (ions m/z 195, 210, 212), quantified on the m/z 195 ion, and the internal standard 2,4,6-trichloroanisol-d 5 (ions m/z 199, 215, 217) quantified on ion m/z 215.. For the determination of ECD, identify the analyte and internal standard (2,6- dibromoanisole or 2,3,6 trichloroanisole) in the chromatogram, by comparing the retention time of the sample peak corresponding to that of the standard solution peak. 7. CALCULATIONS The area of the chromatographic peak obtained for the 2,4,6- trichloroanisole is corrected by the area obtained for the chromatographic peak of the internal standard. The content in of each sample is obtained using a calibration curve. The points on this curve are obtained by tracing the relative responses of the /internal standard, obtained for OIV-MA-AS315-16 : R2009 4

aqueous-alcoholic solutions (3.7) containing known concentrations of 2,4,6- trichloroanisole, as a function of the concentrations of these solutions (3.14). The results are given in ng/l of TCA present in the maceration, rounded off to the nearest 0.1 ng/l. 8. CHARACTERISTICS OF THE METHOD As an indication, the detection limit of the analysis of the macerations must be lower than 0.5 ng/l, and the quantification limit close to 1 ng/l. The coefficient of variation is lower than 5% for 5 ng/l, when the selected internal standard is the deuterated analogue TCA-d 5. An interlaboratory trial was carried out in order to validate the method. This interlaboratory trial was not carried out according to the OIV protocol and the validation parameters mentioned in the FV 1224. 9. BIBLIOGRAPHY HERVÉ E., PRICE S., BURNS G., Chemical analysis of TCA as a quality control tool for natural corks. ASEV Annual Meeting. 1999. ISO standard 20752:2007 Cork stoppers Determination of releasable 2, 4, 6- trichloroanisol (TCA). FV 1224 - Résultats de l analyse collaborative Ring test 3-TCA SPME. OIV-MA-AS315-16 : R2009 5