State Unitary Enterprise Production Amalgamation Novosibirsk Instrument-Making Plant PN-6K. Servise Manual

Similar documents
FSUE PA Novosibirsk. PO3-9x24, PO3-9x24-1. Instruction manual

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

EE 1/3.5х14 U EE 1/3.5х14 U

"VEBER" Telescopic Sights

Federal State Unitary Enterprise КО-60. Registration certificate

USER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch

LEAPERS, INC. RED/GREEN DOTS

Manual Moscow, Night vision rifle scope Dedal- 450 (Gen.II+)

ULTRA SHOT PLUS - DARK EARTH REFLEX SIGHT SM26008DE

USER MANUAL REFLEX SIGHT. Ultra Shot Plus

Red and Green Dot Sight FF26002 USER MANUAL

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

The Vortex Razor HD Gen II-E 1 6x24 Riflescope

JDV CONTROL VALVES CO., LTD. JCT/JCTM Series 3/4 Way Trunnion Type Valve Manual

Second Focal Plane MOA

Dual Use: Shooting Tactical / Hunting US Patent 8,166,696 US Patent 7,937,879. Radius Bar. Reticle Focus. Elevation Adjustment Knob

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

One-Year Limited Warranty

Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR

The Vortex Razor HD Gen II 1 6x24 Riflescope

Operating Manual 1.1-4x24 Zenith x24 Zenith

ZFK 4 X 25. Description and Utilization Instructions

Second Focal Plane MRAD

1-6 x 24 Second Focal Plane MOA

NVRS 3x42 NIGHT VISION RIFLESCOPE USER MANUAL

NVRS Titanium 2.5x50 Night Vision Riflescope

EPOCSELFIR LACITCATiX5T TECHNICAL MANUAL

P4Xi TACTICAL Riflescope TECHNICAL MANUAL

5-25x56 PMII PSR Illuminated with Double Turn

USER MANUAL. Wolverine FSR and CSR Series SM26020 SM26020DE SM26020-LQD SM26021 SM26021DE SM26021-LQD

Directions for use

USER MANUAL. Wolverine FSR and CSR Series SM26020 SM26021 SM26020-LQD SM26020-LQD

HD Gen II 1 6x24 Riflescope. The Vortex Razor

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

30 mm Diameter Main Tube 1-4x24 Models

1x COMBAT DOT SIGHT USER MANUAL

The Vortex. Dual Use: Shooting Tactical / Hunting US Patent 8,166,696 US Patent 7,937,879. Elevation. Adjustment Dial.

BINOCULAR STEREOSCOPIC MICROSCOPE MBS-10. User Manual

Operator s Manual SpecterOS 4x by ELCAN

SpecterOS4x Optical Sight Operation Manual

ROMEO ROMEO6 1x30mm FULL SIZE RED DOT SIGHT

???? The Vortex Crossfire II Riflescopes

WARNING: Ensure weapon is not loaded prior to mounting riflescope.

2-7x32. Instruction manual

Please read entire manual before using your new optic. Fast Focus Eyepiece. Elevation Turret. MAG-Bar. Side Focus Dial (Select Models) Reticle Focus

SpecterOS3.0 Optical Sight Operation Manual

Operating Instructions Spectro-Goniometer Student. 1 Functional Elements. 2 Safety Precautions. Figure 1: Spectro-Goniometer Student

RITON RT-S Mod x56 Illuminated Reticle Riflescope Manual

ROMEO ROMEO4 1x20mm COMPACT RED DOT SIGHT

Table of Contents. Specifications 1 Adjustments 2 Using the Reticle 8 Maintenance 16 Troubleshooting 18 SS Warranty 19

USER MANUAL. Core TX Riflescope Series

RT-6 Riflescopes. User Guide

User Manual for Blackhawk Riflescope

RITON RT-S Mod 3 1-4x24 Illuminated Reticle Riflescope Manual

MC ILLUMINATED USER MANUAL

30 mm Diameter Main Tube

USER MANUAL RIFLESCOPES. Triple Duty & Tactical Series. English / Francais / Español / Deutsch

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

RIFLE SCOPE INSTRUCTION MANUAL

USER MANUAL. EZEKIEL 3-30x56. Riflescope. English / Francais / Español / Deutsch

DIGITAL ABBE REFRACTOMETER INE-WYA-2S OPERATING INSTRUCTION PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Second Focal Plane Reticle

Instruction Manual. Made in Japan

Flexbar 6.3:1 MANUAL ZOOM STEREO MICROSCOPE. 250 Gibbs Road, Islandia, NY (P) (F)

WHEN BRIGHTNESS COUNTS

INTREPID x 50 Riflescope

Dual Red or Green Electronic Dot Sight Instruction Manual

5-25x56 PMII PSR With Double Turn

ABOUT SIGHTMARK. Sightmark - MAKE YOUR MARK

OWNER S MANUAL 4 16X X X44

RIFLESCOPE RIFLESCOPE MANUAL

CAUTION: BEFORE INSTALLATION, CONFIRM THAT THE CROSSBOW IS UNLOADED AND IS IN SAFE OPERATING CONDITION.

Telescope Sight 4 X 24 for G3 Rifle

Telescope. 1. Read these instructions carefully and familiarise yourself with the procedure before assembling the unit.

PK-01 MILITARY RED DOT RIFLE SCOPE FAMILY

product manual H-3220A Benkelman Beam

CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

C4 PLUS RIFLESCOPES User Guide

NcSTAR SHOOTER II SERIES SCOPE

Owner's Manual. for AUTOMATIC LEVEL. NBL Series. FOR CUSTOMER SERVICE, PARTS & REPAIR, CALL Toll Free:

AGES INSTRUCTION MANUAL. Juno 50mm Telescope Space Exploration Gear

USER MANUAL CORE SHOT A-SPEC FMS REFLEX SIGHT CORE SHOT A-SPEC LQD REFLEX SIGHT

Lamp and Control Panel (Lamp Panel)

Z650HR SERIES MANUAL ZOOM STEREO MICROSCOPE. 73 Mall Drive, Commack, NY (P) (F)

Reflex Red Dot Sight. Model # / AR / AR730005C. Lit #: /03-13

Columbia University Astronomy Big Dome Telescope Start up/shut Down

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

AGES CF600PM. 50 mm Telescope w/ AZ Pan Tilt Mount Instruction Manual. WARNING! SUN HAZARD: Never look directly at the sun with this device.

SKELESCOPE REFLECTOR TELESCOPE WITH TABLE TOP TRIPOD SK-100 INSTRUCTION MANUAL

6XMag-1 Magnifier User manual

x Builders Level Service Manual

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

RANGER 1-4 x 24 RIFLESCOPE

DWT-10 Instruction Manual

LED light engines LED linear / area

RED DOT SERIES ILLUMINATED SIGHTS INSTRUCTION MANUAL

Binocular Riflescope Instruction Manual M

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

SCHIEBER TELESCOPES. Unique, High-Quality Telescopes

Transcription:

State Unitary Enterprise Production Amalgamation Novosibirsk Instrument-Making Plant Night Sight PN-6K Servise Manual

Contents 1. General directions 4 2. Specifications 5 3. Delivery set 6 4. Safety regulations 6 5. Design and principle of operation 7 6. Pre-starting procedure and operation 7 7. Maintenance 11 8. Storage 17 9. Troubleshooting 17 10. Acceptance certificate 20 11. Warranty

1. General directions. The night vision sight PN-6K (hereinafter referred to as sight ) is designed for pointing hunting weapons with side mount such as Tiger, Saiga and Vepr. Operating temperature: -50 C to +40 C. WARNING: It is strictly prohibited to switch on the sight in the daytime without the protective cup on the lens as well as to observe the bright luminous objects such as straight headlight, campfire etc. 4

2. Specifications Visual range under starlight conditions, m, njt less 00 Magnification, x 4 Field of view, deg 8 Supply voltage, V 1.5 Operating time, h at T= +25 C 12 at T= - 40 C 3 Weight, kg 0.93 Overall dimensions, mm 207x79x176 5

3. DELIVERY SET Night Sight PN-6K Control devise UK - 316 1 Eyeshield Wrench Napkin Bag Box 1 Servise manual 4. Safety regulations The device is safe to handle due to its principle of operation, design, components and materials used. To avoid a pollution of environment it is recommended to utilize out the used supply cells only in the places assigned for waste utilization. 6

5. Design and principle of operation Night sight PN-6K is an electrooptic device. Its principle of operation is based on the intensification of image brightness by image intensifier. The objective sight consists of lens, image intensifier (II), eyepiece and AA power supply mounted into the housing. 6. Pre-starting procedure and operation Sight is mounted on a weapon by means of a clamp which consists of bracket 16 (Fig.1,2), lock screw 12, latch 13, lock lever 14, handle 15 and washer 11. Mount the sight on a weapon in the following order: - pull the handle 15; - direct the sight from the butt side into aligning bar of a weapon and push the sight forward to stop; - push the handle 15 up untill snaps to the bracket; - check up the reliability of sight fastening. 7

Swinging of the sight on a weapon is not permitted. For reliable fastening of the sight, it is necessary to adjust the clamp in the following order: - take off the sight from a weapon; - unlock the latch 13; - shift the handle 15 by teeth number providing the reliable fastening; - lock the latch 13; - check up the reliability of sight fastening again. For mounting the sight and checking its effictency under daylight conditions do folloving: - put the cup with light filter on the lens; - remove the cover 8 and insert the battery as shown on the cover of the sight; - screw up the cover 8; - switch on the switch 7. In 3-4 seconds the eyepiece field of view should begin to shine with yellowgreen light and red aiming reticule; - adjust the optimal contrast of aiming reticule by means of turning the 8

handwheel 17; - if the sight is switched an, the screen shines, but the reticle is inveisible. the battery should be replaced. Warning: the reticule extinction indicates the discharge of battery. The central peak of reticule is assigned for sighting. The sight should be aligned to the weapon by means of zeroing. Zeroing is carried out in the daytime and only with the light filter cap put on It is done, in the following order: - set the target of approximately 1x1 m at a distance of 100 m; - make 3-4 shots aiming the peak of the reticle to the centre of the target; - determine the center of impact by holes in the target. If the center of impact has a difference with the aiming mark exceeding 3 cm, the alignment of the sight is needed. It is carried out by means of turning the screws of vertical and horizontal adjustment mechanisms. One click of the center of impact by 3 cm ata range of 100 m. Make the batch of check shooting. Grouping of sight aimed shooting should not be worse than without sight. 9

No adjustment should be made after zeroing. While shooting at a range exceeding 100 m keep zeroing but choose the second aiming point corresponding to the range of target (Fig.3). The sight canbe used without a light filter 1 (Fig.2) Only in the night time with illumination up to 10-2 lux. The sight is provided with a control devise UK - 316 intended for ckecking the charge of the battery. There are four lights an tne boord of UK - 316 (Fig.4) showing the voltage. When necessary, install the battery into the UK - 316 keepting in mind the polarity. The light, which blazes up shows the level of the charge. After using the sight, turn the switch 7 (Fig.2) into OFF position. 10

7. Maintenance The device should be kept clean of dust and dirt. The outer surfaces of the optical parts should be always clean. Warning: It is prohibited: - to disassemble the sight; - to switch on the sight in the daytime without protective cap and light filter;on; - to apply exceeding force to clamp; - to use a battery of improper type; - to keep a battery into the unused sight for a long time The sight is the subject of following periodic maintenance procedure: - clean the sight from dust, dirt and moisture; - check the contacts of power supply; - wipe grease spots on optical surfaces by clean napkin; in case of significant pollution alcohol can be used; 11

Figure 1. Sight (left side view) without cap and light filter. 2 lens; 3 fitting part; 4 - sight housing; 5 clip; 6 eye-shield; 8 battery compartment cover; 9 lead; 10 sight housing cover; 11 washer; 12 stop screw; 13 latch; 14 lock lever; 15 handle; 16 bracket; 17 reticle brightness adjustment handhweell. 12

2 3 4 5 6 17 8 16 15 14 13 12 11 10 9 Figure 1. Sight (left side view) without cap and light filter. 13

Figure 2. Sight (right side view) 1 cup with light filter; 7 switch; 18 vertical adjustment screw; 19 cover of blowout fitting; 20 rubber gasket; 21 horizontal adjustment screw. 14

18 19 20 21 1 7 Figure 2. Sight (right side view) 15

16 Figure 3.

8. Storage The sight must be protected from the mechanical damages. The sight is to be stored in a heated room. Ambient temperature must be from 5 to 35 C. Relative humidity must not exceed 85%. It is recommended to keep the sight in its carrying bag with no a battery in it. 9. Troubleshooting In case of a disorder check the follows: - the mounting of the sight on the weapon; - whether the protective cup with light filter is put on; - the cleanness of optical surfaces; - possible discharging of the battery; - whether the power supply is switched on; - the cleanness of contacts of power supply. 17

Possible malfanctions and methods of elimination are listed below. Table 1 trouble possible cause method of elimination 1) Incorrect setting of battery The screen of image intensifier does not shine The image brightness rises to maximum and falls down fast or fluctuates disturbing the sight operation 1) Check The battery setting keeping in mind the polarity 2) Battery is discharged 2) Replace the battery 3) Image intensifier doesn' t work Light overload operable 3) Send the sight to a repair shop Put the cup with light filter on the lens of the sight 18

trouble possible cause method of elimination Image is weak and Sweating or pollution of the Wipe the outer optical blurred outer optical surfaces surfaces Image is weak and blurred, flashing and blinking are observed in the field of view Sweating of the inner surfaces of optics and image intensifier Send the sight to a repair fshop for drying and sealing Dark spots appear in the field of view, disturbing the sight operation Reticule is absent or weak when image intensifier shines The image intensifier is damaged by light sources. The photocathode flaking appears 1) The reticule illuminator is defective 2) The battery is discharged Send the sight to a repair shop 1) Send the sight to a repair shop 2) Replace the battery 19

10. Acceptance certificate Night Sight PN-6К, serial, is in compliance with specifications and found fit for service. Date of manufacture Signatures State Unitary Enterprise Production Amalgamation Novosibirsk Instrument-Making Plant, 179/2, D.Kovalchuk, Novosibirsk, 630049 Russia Tel: (3832) 25-45-42; Tel/Fax : (3832) 26-17-68 20