TEST REPORT. Page : 1 of 9 Report No. RT14R-U E Date: Oct. 13, : The following submitted sample(s) said to be:-

Similar documents
TEST REPORT. : The following submitted sample(s) said to be:-

TEST REPORT. : Lead Frame / Ag is plated on Ni-Fe Alloy-A42 material

TEST REPORT. Address : , Doksan-dong, Geumcheon-gu, Seoul, Korea Page: 1 of 12 Report No. RT16R-S E Date: Jul.

TEST REPORT. : The following submitted sample(s) said to be:- SAMPLE RECEIVED : Jan. 07, 2019 TESTING DATE : Jan. 07, 2019 ~ Jan.

TEST REPORT : SR A-DC, SR A-DA, SR A-DT, SR A-DN, SR C-DC, SR C-DA, SR C-DT, SR C-DN

TEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.

TEST REPORT. ADDRESS : 77, Seokam-ro 13-gil, Iksan, Jeonllabuk-do, Korea PAGE: 1 of 8 REPORT NO. RT17R-U2181-E DATE: Dec. 29, 2017

TEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.

TEST REPORT. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory.

Page 2 of 8 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

Test Report No. : KA/2012/61391 Date : 2012/06/28 Page : 2 of 9 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUND Test Item (s): Unit Metho

Test Report No. : KA/2012/41514 Date : 2012/05/07 Page : 2 of 9 Test Result(s) PART NAME NO.1 : SILVER NIPPON COPPER WIRE Cadmium (Cd) mg/kg With refe

Test Report No. : CE/2009/45866B Date : 2009/05/20 Page : 1 of 7

Test Report No. CANEC Date: 01 Sep 2011 Page 1 of 8

Test Report. Report No. RLSHD Page 1 of 6

Test Report No. : KA/2012/40043 Date : 2012/04/10 Page : 2 of 8 Test Result(s) PART NAME NO.1 : BLACK EPOXY MOLDING COMPOUNDS Test Item (s): MDL Resul

Test Report Number: SHAH Applicant: TE CONNECTIVITY Date: 22 Feb, 2017 BUILDING A5,NO.1528 GUMEI ROAD, SHANGHAI,CHINA Attn: CC WU

Page 2 of 12 Test Result(s) PART NAME No.1 IC TRANSCEIVER Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performed by

No. CE/2012/44922 Date 2012/05/03 Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalen

Chemical Laboratory - Kao., Test Report No. : KE/2018/11379 Date : 2018/01/25 Page : 2 of 8 Test Result(s) PART NAME NO.1 : CLEAR FAL FILM WITH ADHESI

Test Report. Report No. ECL01I Page 1 of 7

Page 2 of 12 Test Result(s) PART NAME No.1 YELLOW LUMP Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs Monobro

Page 2 of 10 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

Test Report MITSUI HIGH-TEC (SHANGHAI) CO.,LTD NO.2001 XINJIN QIAO ROAD EXPORT PROCESSING ZONE PUDONG SHANGHAI CHINA

Test Report No. : KE/2016/B2076 Date : 2016/11/24 Page : 2 of 8 Test Result(s) PART NAME NO.1 : GRAY Test Item (s): Unit Method Cadmium (Cd) mg/kg Wit

Test Report No. : CE/2013/51536 Date : 2013/05/29 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa

Thin Film on Silicon Resistor Networks Models 2NBS, 2QSP Mold Material Change

Page 2 of 9 Test Result(s) PART NAME No.1 DARK BROWN PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and pe

Test Report No. : CE/2014/50660 Date : 2014/05/22 Page : 2 of 14 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Test

Test Report No. : CE/2014/B4428 Date : 2014/12/03 Page : 1 of 12 PELNOX CO., LTD. 8-7 BODAI, HADANO CITY, KANAGAWA , JAPAN *CE/2014/B4428* The

Page 2 of 12 Test Result(s) PART NAME No.1 DK. BROWN LUMP Cadmium (Cd) Lead (Pb) Mercury (Hg) Antimony (Sb) Beryllium (Be) Test Item(s) Hexavalent Chr

Test Report No. : CE/2014/32788 Date : 2014/03/27 Page : 2 of 14 Test Result(s) PART NAME No.1 : YELLOW SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test

Test Report No. : KA/2012/21431 Date : 2012/02/24 Page : 2 of 12 Test Result(s) PART NAME NO.1 : SILVER GRAY DIE ATTACH PASTE Test Item (s): Unit Meth

Test Report No. : KA/2014/61579 Date : 2014/07/07 Page : 2 of 14 Test Result(s) PART NAME NO.1 : GOLD BONDING WIRE Test Item (s): Unit Method Cadmium

Test Report No. : CE/2008/38467 Date : 2008/04/07 Page : 2 of 11 Test Result(s) PART NAME NO.1 : BLACK PLASTIC TUBE Cadmium (Cd) Lead (Pb) Mercury (Hg

Page 2 of 11 Test Result(s) PART NAME No.1 TRANSPARENT-YELLOW PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KE/2017/40842 Date : 2017/04/17 ROGERS CORPORATION 245 WOODSTOCK ROAD, WOODSTOCK, CT. 06

No. CE/2012/C1503 Date 2012/12/18 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

Test Report No. CE/2014/43454A Date 2014/04/23 Page 2 of 11 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Ite

Page : 2 of 12 Test Result(s) PART NAME No.1 : MIXED ALL PARTS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Test Report No. : CE/2015/15894 Date : 2015/02/04 NIHON ALMIT CO., LTD. ALMIT BLDG., , YAYOICHO, NAKANO-KU, TOKYO, JAPAN Page : 1 of 7 *CE/2015/

No. KE/2016/52417 Date 2016/05/26 Page 2 of 6 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) ( ) Sum of

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) Sum of PBBs

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With reference to IEC (2013) an

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Test Report No. CTSSA/13164/14 Date: 11/07/2014 Page: 1 of 10 CTS Ref. CTSSA/14/2009/Redring

Test Report No. SH /CHEM Date: Oct. 22, 2009 Page 1 of 5

Page 2 of 12 Test Result(s) PART NAME No.1 INTEGRATED CIRCUITS Test Item(s) Cadmium (Cd) Unit Method With reference to IEC (2013) and performe

Chemical Laboratory - Kao., SGS Taiwan Ltd. Test Report No. : KA/2017/50850 Date : 2017/05/25 HERAEUS MATERIALS SINGAPORE PTE LTD BLOCK 5002, ANG MO K

Test Report No. : CE/2009/34977 Date : 2009/03/25 Page : 1 of 10

Test Report No. KD/2013/50027A-01 Date 2013/07/01 Page 2 of 6 Test Result(s) PART NAME No.1 PART NAME No.2 PART NAME No.3 Cadmium (Cd) Lead (Pb) Mercu

Test Report No. : KA/2010/C2116 Date : 2011/01/05 Page : 2 of 6 Test results by chemical method (Unit: mg/kg) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexa

The following sample(s) was/were submitted and identified by/on behalf of the client as : (2) (3) (4) (5) Please refer to next page(s).

No. : CE/2012/A3090 Date : 2012/10/23 GAP PAD 1000SF RICK STEWART REPORT PER REQUEST FOR QUOTE, DATED 10/5/11

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Test Item(s) Unit Method mg/kg With reference

Test Report No. KE/2017/C1499 Date 2018/01/02 Page 2 of 7 Test Result(s) PART NAME No.1 WHITE POLYOXYMETHYLENE Test Item(s) Cadmium (Cd) Lead (Pb) Mer

No. CE/2014/51910 Date 2014/05/20 Page 2 of 5 Test Result(s) PART NAME No.1 Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Cadmium (Cd) Test Item(s) Unit Method mg/kg With r

TEST REPORT Report No. : GR:HL: DATE : 20/11/2014

Chemical Laboratory - Kao., Page 2 of 14 Test Result(s) PART NAME No.1 BLACK EPOXY MOLDING COMPOUND Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) H

Page 2 of 10 Test Result(s) PART NAME No.1 LT.GRAY SHEET Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (2013) and perf

Management number No. KA/2015/80033 Date 2015/08/10 Page 1 of 6 The following sample(s) was/were submitted and identified by/on behalf

Test Report. Report No. SCL03H Page 1 of 7

Test Report No. CTSSA/27121/12 Date : 04/01/2013 Page: 1 of 5 CTS Ref. CTSSA/12/4387/Luvata

Test Report. Report No. RLSHE Page 2 of 5 Test Result: Content 1 2

Page 2 of 11 Test Result(s) PART NAME No.1 COPPER/SILVER COLORED METAL SHEET (INCLUDING THE PLATING LAYER) Cadmium (Cd) Test Item(s) Unit Method With

Page 2 of 11 Test Result(s) PART NAME No.1 YELLOW/WHITE PAD (EXCLUDING THE RELEASE FILM) Cadmium (Cd) Lead (Pb) Test Item(s) Unit Method With referenc

Test Report No. F690101/LF-CTSAYAA

Page 2 of 10 Test Result(s) PART NAME No.1 MIXED BLACK AND WHITE PASTE Test Item(s) Cadmium (Cd) Lead (Pb) Unit Method With reference to IEC (

Test Report No. CRSSA/02575/18 Date : 09/03/2018 Page: 1 of 13 CRS Ref. CRSSA/18/0530/Dynacraft

TEST REPORT Report No. : GR:HL: DATE : 27/10/2014

Test Report No. CRSSA/01754/18 Date : 19/02/2018 Page: 1 of 11 CRS Ref. CRSSA/18/0368/Ametek

CHI NHANH CONG TY TNHH SAN XUAT THUONG MAI HA PHONG -XUONG SAN XUAT

Test Report No. CTSSA/ /12 Date : 10/01/2012 Page: 1 of 5 CTS Ref. CTSSA/12/0018/Straits

Page 2 of 9 Test Result(s) PART NAME No.1 SILVER COLORED PASTE Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexavalent Chromium Cr(VI) Sum of PBBs

Test Report No. CE/2015/C2965A Date 2016/02/16 Page 2 of 7 Test Result(s) PART NAME No.1 MIXED ALL PARTS Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item

Test Report No: (1) R1 Date: 29-Apr-13 Page 1 of 5

Page : 2 of 19 Test Result(s) PART NAME No.1 : COPPER COLORED METAL SHEET (EXCLUDING THE FRAME) Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) Hexav

ICP Test Report Certification Packet

Test Report No. CRSSA/25672/16 Date : 08/12/2016 Page: 1 of 9 CRS Ref. CRSSA/16/2799/Ametek

Test Report. Report No. ECL01H Page 1 of 9

Chemical Laboratory - Kao., Page : 2 of 18 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) :

Test Report No. CRSSA/03608/18 Date : 28/03/2018 Page: 1 of 7 CRS Ref. CRSSA/18/0736/Toray

Test Report No. CE/2016/43515 Date 2016/04/22 Page 2 of 7 Test Result(s) PART NAME No.1 AMBER FILM Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) He

Test Report No. CRSSA/ /17 Date : 04/01/2018 Page: 1 of 5 CRS Ref. CRSSA/17/3272/Toray

Test Report No. CTSSA/ (AD)/13 Date: 27/11/2013 Page: 1 of 5 CTS Ref. CTSSA/13/3631/Redring

Test Report No. : CE/2014/A2569 Date : 2014/10/22 Page : 2 of 20 Test Result(s) PART NAME No.1 : GOLDEN COLORED METAL WIRE Cadmium (Cd) Lead (Pb) Merc

TEST REPORT NUMBER: SHAH TESTS CONDUCTED. (A) TEST RESULT SUMMARY FOR RoHS DIRECTIVE:

Test Report No. CRSSA/ /17 Date : 22/02/2017 Page: 1 of 9 CRS Ref. CRSSA/17/0450/EQX

ICP Test Report Certification Packet

Test Report No. CRSSA/08508/17 Date : 12/07/2017 Page: 1 of 9 CRS Ref. CRSSA/17/1742/CSC

Test Report No. CE/2017/62572 Date 2017/06/19 Page 2 of 7 Test Result(s) PART NAME No.1 PINK SHEET Cadmium (Cd) Lead (Pb) Mercury (Hg) Test Item(s) He

Test Report NANTONG HUADA MICROELECTRONICS GROUP CO., LTD NO.99 ZILANG ROAD,NANTONG CITY,JIANGSU PROVINCE

Chemical Laboratory - Kao., Page 2 of 18 Test Result(s) PART NAME No.1 Test Item(s) Cadmium (Cd) Lead (Pb) Mercury (Hg) Hexavalent Chromium Cr(VI) ( )

Test Report KUO SEN ENTERPRISE CO.,LTD NO.87-2 NINGPAO WEST ST. TAIPEI, TAIWAN, R.O.C

Test Report. Report No.RLSZE Page 1 of 11

Transcription:

Applicant Address : PSMC Co., Ltd. : #52, Banyeo-1dong, Haeundae-gu, Busan, Korea Page : 1 of 9 Sample Description : The following submitted sample(s) said to be:- Name/Type of Product Name of Material Sample ID No. Manufacturer/Vendor : Lead Frame : Cu Alloy-C194 : RT14R-U1943-002 : PSMC Co., Ltd. Sample received : Oct. 06, 2014 Testing Date : Oct. 06, 2014 ~ Oct. 13, 2014 Test Type Test Method(s) Test Result(s) : RoHS wet chemical analysis : Please see the following page(s). : Please see the following page(s). * Note 1 : The test results presented in this report relate only to the object tested. * Note 2 : This report shall not be reproduced except in full without the written approval of the testing laboratory. Approved by, Authorized by, E.Y.Lee / Lab. Technical Manager H.W.Yoo / Lab. General Manager

Page : 2 of 9 Test Item Unit Test Method MDL Result Cadmium (Cd) With reference to IEC 62321-5 Edition 1.0 : 2013, by acid digestion and 0. Lead (Pb) determined by ICP-OES 5 20 Mercury (Hg) Hexavalent Chromium (Cr 6+ ) (For metal) Hexavalent Chromium (Cr 6+ ) (For metal) Tested by : YK Cho, HJ Kim - - With reference to IEC 62321-4 Edition 1.0 : 2013, by acid digestion and determined by ICP-OES With reference to IEC 62321 Edition 1.0 : 2008, by Spot test With reference to IEC 62321 Edition 1.0 : 2008, by boiling water extraction and determined by UV-VIS Spectrophotometer 2 N.D. (Threshold of 1 ) (Threshold of 0.02 with 50 cm 2 ) Negative Negative Notes : = ppm = parts per million with 50 cm 2 = milligram per kilogram with 50 square centimeter < = Less than N.D. = Not detected ( <MDL ) MDL = Method detection limit Positive = A positive test result indicated the presence of Cr(VI) at the time of testing, equal to or greater than threshold of 1 for spot test procedures or 0.02 for boiling water extraction procedures with a sample surface area of 50 cm 2 used. However, it shall not be interpreted as the Cr(VI) concentration in the coating layer of the sample and should not be used as a method detection limit for this qualitative test. Negative = A negative test result indicates above positive observation was not found at the time of testing. When the spot test showed a negative result, the boiling water extraction procedure shall be used to verify the result.

Page : 3 of 9 Test Item Unit Test Method MDL Result Polybrominated Biphenyl (PBBs) Monobromobiphenyl Dibromobiphenyl Tribromobiphenyl Tetrabromobiphenyl With reference to Pentabromobiphenyl IEC 62321 Edition 1.0 : 2008, Hexabromobiphenyl by solvent extraction and Heptabromobiphenyl determined by GC/MS Octabromobiphenyl Nonabromobiphenyl Decabromobiphenyl Polybrominated Diphenyl Ether (PBDEs) Monobromodiphenyl ether Dibromodiphenyl ether Tribromodiphenyl ether Tetrabromodiphenyl ether With reference to Pentabromodiphenyl ether IEC 62321 Edition 1.0 : 2008, Hexabromodiphenyl ether by solvent extraction and Heptabromodiphenyl ether determined by GC/MS Octabromodiphenyl ether Nonabromodiphenyl ether Decabromodiphenyl ether Tested by : MB Song Notes : = ppm = parts per million < = Less than N.D. = Not detected ( <MDL ) MDL = Method detection limit

Page : 4 of 9 Test Item Unit Test Method MDL Result Antimony (Sb) With reference to US EPA 3052, by acid digestion and 2 N.D. determined by ICP-OES Bromine (Br) With reference to EN 14582, by oxygen combustion with 30 N.D. bomb and determined by IC Chlorine (Cl) With reference to EN 14582, by oxygen combustion with 30 N.D. bomb and determined by IC Fluorine (F) With reference to EN 14582, by oxygen combustion with 30 N.D. bomb and determined by IC Iodine (I) With reference to EN 14582, by oxygen combustion with bomb and determined by IC 30 N.D. With reference to US EPA Perfluorooctanoic acid 3550C & 8321B, by ultrasonic (PFOA) extraction and determined by LC/MS/MS 0.1 N.D. Perfluorooctane sulfonate (PFOS) Tested by : YK Cho, Shirley Park Notes : = ppm = parts per million < = Less than N.D. = Not detected ( <MDL ) MDL = Method detection limit With reference to US EPA 3550C & 8321B, by ultrasonic extraction and determined by LC/MS/MS 0.1 N.D.

Page : 5 of 9 * View of sample as received;-

Page : 6 of 9 Flow Chart (IEC 62321 Edition 1.0) Receipt Sampling/ Grinding or Cutting Pb, Cd, Hg Cr 6+ PBBs /PBDEs Metal For different material, digest the sample with appropriate acid *1 Confirm the tested samples are totally dissolved *3 Make up with deionized water Spot test *2 Negative Get 50cm 2 sample Boiling water extraction Make up with deionized water and add diphenyl-carbazide solution Weigh sample and add organic solvent Soxhlet extraction or solvent extraction Concentrate the extract and make up with organic solvent Analyzed by ICP-OES Analyzed by UV-VIS Analyzed by GC-MS Remarks : *1 : List of appropriate acid: Material Acid added for digestion Polymers HNO 3, HCl, HF, H 2O 2, H 3BO 3 Metals HNO 3, HCl, HF Electronics HNO 3, HCl, H 2O 2, HBF 4 *2 : If the result of spot test is positive, Chromium (VI) would be determined as detected. No further analysis is required. *3 : The samples were dissolved totally by pre-conditioning method according to above flow chart.

Page : 7 of 9 Flow Chart (Metal Testing) Receipt Sample preparation Sample measurement NO Microwave digestion with HNO 3 / HCl / HF Total digestion YES Analyzed by ICP-OES ** Remarks : The samples were dissolved totally by pre-conditioning method according to above flow chart.

Page : 8 of 9 Flow Chart (Halogen) Receipt Sample preparation Sample weighing Bomb preparation Combustion Absorption solvent preparation of absorption solution Cooling, for 1hr Collection of halides make up Vol. 100mL Analyzed by IC

Page : 9 of 9 Flow Chart (PFOS, PFOA) Receipt Sample preparation Loading in a vial Methanol loading Ultrasonication Filtering & Cleaning Make up (Methanol) Analyzed by LC/MS/MS ***** End of ***** This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct.