Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Similar documents
Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Using UHPLC-Triple Quadrupole MS/MS to Detect the Presence of Bark Extract and Yohimbine Adulteration in Dietary Supplements and Botanicals

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

materials analysis Solutions for Your Analytical Business Markets and Applications Programs

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Application Note. Abstract. Authors. Environmental

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes Application

Measuring Drug-to-Antibody Ratio (DAR) for Antibody-Drug Conjugates (ADCs) with UHPLC/Q-TOF

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

Application Note. Food. Abstract. Author

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120

Ultrafast Analysis of Methadone and Metabolite EDDP in Urine by the Agilent RapidFire High-Throughput Mass Spectrometry System

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Agilent ESI and APCI sources: for polar to non-polar compounds

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

Accurate Mass Analysis of Hydraulic Fracturing Waters

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

Application Note. Authors. Abstract. Introduction. Environmental

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges

Automated Sample Preparation in Quality Control of Eye-Drop Formulation

Analysis of Positional Isomers of Lapatinib with Agilent Poroshell 120 PFP Columns

CZE analysis of artificial sweeteners and preservatives in drinks

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Detection of Trace Level Pharmaceuticals in Drinking Water by Online SPE Enrichment with the Agilent 1200 Infinity Series Online-SPE Solution

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Modernizing the USP Monograph for Acetaminophen

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Analysis of Cannabinoids and Amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source. Application.

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Routine Multiresidue Pesticide Analysis using the Agilent 6470 Triple Quadrupole Mass Spectrometer

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Analysis of Phthalates in Body Wash using Solid-Supported Liquid-Liquid Extraction

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

Anaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Highly sensitive and rapid analysis of synthetic dyes in sea food by LC/MS/MS

Simultaneous Determination of 26 Mycotoxins in Sesame Butter Using Modified QuEChERS Coupled with UHPLC-ESI/Triple Quadrupole Mass Spectrometry

Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application

Analysis of Saponins in Spine Date Seed using Agilent ZORBAX Solvent Saver HT (1.8 µm) Columns

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System

Determination of Hormones in Serum by LC/MS/MS Using Agilent Bond Elut Plexa SPE

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

The Analysis of Organophosphate Pesticides by LC/MS Application

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

Application Note. Authors. Abstract. Energy & Chemicals, Biofuels & Alternative Energy

Signal, Noise, and Detection Limits in Mass Spectrometry

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Value of Eclipse Plus C18 and ph Selectivity to Analyze Amine-Containing Drugs

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Application. Authors. Abstract. Introduction. Hydrocarbon Processing

Supporting Information

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Quantitative Analysis and Identification of Migrants in Food Packaging Using LC-MS/MS

Highly sensitive quantitative estimation of genotoxic impurities from API and drug formulation using LC/MS/MS

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Transcription:

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry Application Note Food safety Authors Ismael Flores and Carlos Sepulveda Agrolab México Km 7 Carretera Pachuca-Actopan Pachuca México Abstract An LC/MS method for simultaneous determination of four low-calorie sweeteners, Acesulfame K, Aspartame, Stevioside, and Sucralose in soft drinks has been developed. This analysis has three basic characteristics. It is fast, easy to implement, and cheap, which results in a routine analysis with a high throughput and low cost per sample. Ricardo Sánchez Agilent Technologies, Inc. Blvd. A. López Mateos 009-0 Distrito Federal México

Introduction New low-calorie sweeteners have been introduced to the food market in the last decade. This has been the consequence of health issues such as obesity and diabetes. These new low-calorie sweeteners include both synthetic and natural molecules. Food and beverage products can include a single low-calorie sweetener or a mix. These mixes can include synthetic and natural low-calorie molecules in addition to natural sugars such as glucose, fructose, sucrose, maltose, and large oligosaccharides with a degree of polymerization higher than eight, such as inulin. The complexity of adding sweetners to food and beverage products has generated an interest to characterize and quantify the different molecules present in all these products. The analysis of sugars and natural and synthetic low-calorie sweeteners has been approached with different chromatographic and detection techniques. The results demonstrated that the highest degree of sensitivity and selectivity is acquired using the LC/MS methodology. N CH 3 H H NH Aspartame H Cl H H H Cl Sucralose H Cl H H H H 3 C S N K + Acesulfame K H H CH H H It was decided to use positive adduct ESI ionization with neutral ph for the aqueous mobile phase, because acidic aqueous conditions can induce the hydrolysis of oligosaccharides chains, resulting in the inability to quantify these molecules as a routine and robust analysis. Such molecules are the natural sugars, sucrose, maltose, lactose, melibiose, and raffinose. Even though these molecules are not included into this analysis, they can be added later on with no further optimization of the ionization conditions, to generate a single complete composition analysis of low-calorie sweeteners and natural sugars for different food matrices. The use of Lithium as the positive charge modifier has been implemented for this analysis. Lithium adduct was chosen over sodium adducts because there is no evidence of the formation of [M + Li] in contrast with the possibility to form [M + Na] as the H groups increase in the target molecule. This could lead to a more complex optimization and standardization of the methodology. The LC/MS method developed in this application note has three characteristics: does not require pre-run derivatization, does not require post column additives such as CHCl 3, and does not require mobile phase preparation such the addition of triethylamine and formic acid. These three characteristics generate a robust routine analysis with a high throughput and low cost per sample. Figure. H H H H H CH 3 Stevioside Structures of the four low-calorie sweeteners analyzed. Experimental Reagents, solvents and chemicals Acesulfame K, Sucralose, Aspartame, Stevioside standards (Figure ), and lithium chloride salt were purchased from Sigma-Aldrich. Acetonitrile was purchased from Burdick and Jackson. Water was obtained in the laboratory using a Milli-Q Advantage A0 of Millipore purification system. The sonicator system was an Elma E30H Elmasonic. Sample preparation Soft drinks samples, such as flavored water and cola, were diluted,000 fold in water with mm LiCl and injected to the LC/MS system. In the case of cola samples, an additional step of 5 minutes sonication was done prior dilution to eliminate gas bubbles. H

Instrument conditions Samples were analyzed using an Agilent 90 Infinity UHPLC system coupled to an Agilent Triple Quadrupole LC/MS System. HPLC conditions Column Agilent ZRBAX RRHD Eclipse Plus C8,. 50 mm,.8 µm (p/n 959757-90) Flow rate 0.6 ml Column temperature 30 C Injection volume µl Mobile phase A: Water B: Acetonitrile Gradient Time (min) % B 0.0 5.0 0. 5.0. 00. 00.3 5.0 MS conditions Gas temperature 300 C Gas flow 8 L/min Nebulizer 55 psi Sheath gas temperature 50 C Sheath gas flow L/min Capillary 3,500 V for positive and negative polarity Nozzle voltage 500 V for positive and negative polarity Resolution Unit/unit with the exception of sucralose which was widest/unit Results and Discussion The fragmentor and collision energy voltages were optimized for each of the compounds and are listed in Table. Sucralose, Aspartame, and Stevioside were detected in positive polarity as (M+7) +, corresponding to the lithium adduct formation. Acesulfame was detected in negative polarity as (M), corresponding to the loss of the potassium ion. Table. Multiple Reaction Monitoring Information for Each of the Compounds Compound Polarity RT MRM CE Fragmentor Acesulfame K Neg 0.86 6/8 0 35 Stevioside Pos.05 8./69. 55 95 Aspartame Pos 0.9 30./85.9 0 0 Sucralose Pos 0.93 03./05. 0 35 Counts Counts Counts Counts Counts 0.5 0 0 0 0 Acesulfame K Blank Acesulfame K Noise (AutoRMS) = 0.00; SNR (0.859 min) =,8.6 Sucralose Noise (AutoRMS) = 0.6; SNR (0.93 min) =,33. Aspartame Noise (AutoRMS) = 0.0; SNR (0.96 min) = 5,37.8 Stevioside Noise (AutoRMS) = 0.00; SNR (.038 min) = 37,703.8 0. 0.3 0.7 0.9..3.5.7.9. Acquisition time (min) Figure. An example of the chromatogram obtained from a blank (water) and a 50 ppb standard mix of the four low-calorie sweeteners, Acesulfame, Sucralose, Aspartame, and Stevioside. The first quadrupole resolution in all cases was set up to unit (0.7 FWHM), with the exception of Sucralose, which was set up to widest (.5 FWHM). With this setup, injection of the first level of the calibration curve, 50 ppb, shows that the signal-to-noise (S/N) ratio for the four compounds was between,00 and 37,000 (Figure ). This gives assurance that the quantitation will be robust, as the peak heights are well above the baseline. 3

The calibration curve for all of the compounds was done from 50 ppb to 800 ppb, with the exception of Acesulfame, which was from 50 ppb to 600 ppb (Figure 3). Taking into account the normal concentration of these molecules in the beverage products, this allows a,000-fold sample dilution. In addition to this, the fact that the injection volume is µl, leads us to assume that matrix effect will be insignificant. Quadratic fit was observed in some of the compounds, as compared to the linear fit expected. This behavior was already reported in previous publications []. This behavior is probably due to factors such as the nature of the molecules and the conditions used for the analysis as the lithium chlorine salt, column, and gradient. Two beverages samples, cola and flavored water, were tested at a,000-fold dilution (Figure ). The results obtained in the analysis of the cola samples corresponded to the type and concentration of sweeteners listed on the drink s label. In the case of the flavored water samples, the type of sweeteners found corresponded to those listed on the drink s label. For the quantitative results, no concentration values were listed on the label to be compared. 0 3 Acesulfame K.6 y =.5976*x + 53.9868 R = 0.99369..8..0 0.6 0. 0 60 0 80 0 300 360 0 80 50 600 Concentration (ng/ml) 0 3 Aspartame 5 y = 0.005965*x + 0.737*x + 8.5807.5 R = 0.9930353 3.5 3.5.5 0 0 80 0 300 360 0 50 600 Concentration (ng/ml) Figure 3 Example of three replicates of calibration curves for two commonly used low-calorie sweeteners, Acesulfame (top) and Aspartame (bottom). Responses Responses 0. Acesulfame K Noise (AutoRMS) = 0.03; SNR (0.85 min) = 5,89.8 Counts Counts.8.6.. 0.8 0.6 0. 0 9.5 9 8.5 8 7.5 7 6.5 6 5.5 5.5 Aspartame Noise (AutoRMS) = 0.; SNR (0.95 min) = 6.3 0 Aspartame 0 Stevioside 8 Noise (AutoRMS) = 0.08; SNR (0.96 min) = 8,69..5 Noise (AutoRMS) = 0.00; SNR (.09 min) = 6,9.. 7.3 6.. 5 0.9 3 0.8 0.7 0.6 0. 0. 0. 0.3 0. 0.6 0.7 0.8 0.9...3..5.6.7.8 0. 0. 0.3 0. 0.6 0.7 0.8 0.9...3..5.6.7.8 Acquisition time (min) Acquisition time (min) Figure. An example of the chromatograms obtained from a cola (left) and flavored water (right) samples diluted,000 fold and injected to the LC/MS system. Counts Counts

Conclusions This application note demonstrates an LC/MS analysis for four low-calorie sweeteners at concentrations far below the normal usage in the beverage industry, allowing a dilute and shoot approach for a fast, easy and low cost determination. Reference. A. Zygler, et al., Anal. Bioanal. Chem. 00:59-7, 0. For More Information These data represent typical results. For more information on our products and services, visit our Web site at www.agilent.com/chem. 5

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 03 Printed in the USA July 3, 03 599-860EN