Structure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor

Similar documents
SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Rain Watch TM Set up Manual. IC System with Rain Bird IC CONNECT

Data Loggers Outdoor Environment

Website Phone Mobile OVERVIEW Davis Vantage Pro2 Weather Station

Microcare LCD Solar MPPT User Documentation

OASIS WIRELESS WEATHER STATION

Assembly and Operation Manual. April 2016

Overview of the Thunderbird Micronet

Paramaters. Resolution 0.2 m (for measurements < 25 meas. / sec )

MKIII -MB USER S GUIDE 09/18/18. Rev. 3

Device Specifications

WE RE HERE TO HELP: 1 (844) LIGHTCLOUD

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

INFRARED THERMOMETER TM0819

ph Probe ReallyEasyData com

Training Guide. Coastal Environmental Systems, Inc.

6 + WARNING: CHOKING HAZARD - Small parts/small ball(s). Not for children under 3 years.

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Dewpoint Meter Data Sheet / Instructions

PAR Meter Instruction Manual. Product # Product # Year Warranty

Innovative Sustainable Technology

Quick Start Guide New Mountain Visit our Website to Register Your Copy (weatherview32.com)

Data Sheet / Instructions. Dewpoint MeterO

CA84688 FAQS TABLE OF CONTENTS

WEATHER STATION FOR SOLAR FARM MONITORING

Operating Instructions for Digital Manometer. Model: MAN-SD

Instruction Manual. Solar Weather Centre With Wireless Weather Vane. Product Code: WS5056C. Solar Powered Outdoor Weather Data Collector

MET ONE RAIN GAGE MODELS 380, 385, 380M, 385M

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

BERMAD Irrigation. BIC2000 Weather Station SYSTEM GUIDE VERSIONS : BIC ; PC 4.90

WeatherHub2 Quick Start Guide

Experiment 14 It s Snow Big Deal

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

Free fall with an interface system

PiCUS Calliper Version 3

Development of standard calibration equipment for the rain gauges

Activity 1: Investigating Temperature

Pi in the Sky (Sensors) Ian Bragg from Gadsden, AL Jacksonville State University Mentors: Raj and Dr. Loft NCAR SIParCS

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Doc No. KF08-002D. Portable Ultrasonic Flowmeter UFP-20. Installation & Operation Manual

WeatherHawk Weather Station Protocol

Simple circuits - 3 hr

L E A. Laser Elemental Analyzer

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

iweathar EDGE V Installation Guide Copyright 2012 iweathar. All rights reserved.

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

Congratulations on purchasing this WS1516IT Professional Weather Station.

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

2. To measure the emission lines in the hydrogen, helium and possibly other elemental spectra, and compare these to know values.

RainMachine Touch HD- 12 Quick- Start Guide

Spectrometer User s Guide

What is the maximum distance I can have the remote sensors from the display?

Hess' Law: Calorimetry

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

Lab Activity H4 It s Snow Big Deal

Wireless Weather Station. Instruction Manual

Rain Collector (# 7852 & 7852M)

SOFTWARE USER MANUAL. Weather Capture Advance WS1640 WM9280

FREE FALL. To measure the acceleration of a freely falling object.

FoodScreen Radiological Food Screening System

EAS 535 Laboratory Exercise Weather Station Setup and Verification

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide

Installation guide 862 MIT / MIR

Non-Acoustical Inputs

Circular Motion and Centripetal Force

Professional Wind Station

Development of a Remote Automatic Weather Station with a PCbased

Software BioScout-Calibrator June 2013

WeatherLink for Windows

( ) ( ) = q o. T 12 = τ ln 2. RC Circuits. 1 e t τ. q t

Meteorological Service

Graphing Your Motion. Name Period Group

Week 14 The Simple Pendulum

Applications. Remote Weather Station with Telephone Communications. Tripod Tower Weather Station with 4-20 ma Outputs

CABLE FREE TM WEATHER STATION

WS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual

Determination of the Rydberg constant, Moseley s law, and screening constant (Item No.: P )

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

Old Dominion University Physics 112N/227N/232N Lab Manual, 13 th Edition

GS110. IR Thermal Imaging System for Low-Emissivity Glass with Automatic Emissivity Correction. Manual Addendum

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

Acid-Base Titration. Sample

Learning Goals By the end of this lab, you should be able to: Method Part 1 Measurements and calculations using a tipping bucket rain gauge

Minimum (-31) every 10 s -35 (-31)

Evaluation copy. Ground Temperature Measurements. computer OBJECTIVES MATERIALS PRE-LAB QUESTIONS

HD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION

SIMBAD RADIOMETER - INSTRUCTIONS

PRACTICE NO. PD-AP-1309 PREFERRED PAGE 1 OF 5 RELIABILITY PRACTICES ANALYSIS OF RADIATED EMI FROM ESD EVENTS CAUSED BY SPACE CHARGING

Pressure. 1 Fitting PA R - N R2

Digital Multi-Day Max/ Min/Current Air and Soil Temperatures Protocol

O P E R A T I N G M A N U A L

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

WEATHER MULTI-SENSOR. Vaisala Weather Transmitter WXT510. Change the Way You Measure Weather

Introduction Cautions

Transcription:

Rain detection sensor General Description Driving rain and its effective management are critical factors in determining the durability of building enclosures. An accurate measurement of driving rain can be important for risk assessment purposes and in research (where it may be necessary to establish boundary conditions. The driving rain gauge is used to measure the amount of rain falling on the side of a building. It has a unique tipping bucket rain gauge that is effective and long-lasting, with aluminum construction and initial readings as low as 0.05mm of driving rain. Each rain gauge is approximately 12 wide x 17 high x 2.5 deep (30 x 43 x 6 cm) and comes with a standard 12m cable. These gauges must be connected to an A2 Pulse Counter unit. SMT also offers an optional Solar Radiation sensor and External Relative Humidity and Temperature sensors. Applications Assess potential risks due to rain Research (may be necessary to establish boundary conditions) Monitoring wind driven rain effects Features Records wind driven rain over 12 x 17 x 2.5 (30 x 43 x 6 cm) UV resistant Stainless steel construction Rugged design Optional RH, temperature, and solar radiation sensors Comes with standard 12m cable Ordering Information Rain Gauge with A2 Pulse Rain Gauge with A2 Pulse and RH/T Rain Gauge with A2 Pulse and Solar Radiation Rain Gauge with A2 Pulse, RH/T and Solar Radiation RG-01 RG-01-R RG-01-S RG-01-RS Trigger Tape Rain Gauge A2 Pulse Counter (Optional) Solar Radiation Sensor An example of a configuration for the Driving Rain Gauge (non-deployed). Has 1 of the 3 optional sensors available.

A2 Pulse Counter Specifications Electrical Performance Wireless Specification IEEE 802.15.4 Working Frequency Power Output Range (free air) Max Nodes per coordinator Battery Life Type Max Voltage Capacity Self Discharge 2.4 GHz 2.4835 GHz 20dBm (100mW) 1000m. Powered repeaters can be added to extend range. 32 (dependent on application density and acquisition speed) 1 year (hourly sampling) External battery packs available for 3 year sampling. 2 AAA Ni-MH Rechargeable Eneloop HR-4UTGA 3V Typical: 1600 mah Minimum 1500 mah 75% after 3 years Charging Cycles Up to 1500 Charger Memory and USB Memory USB USB 5V 16 Mbit EEPROM for data storage Stores 340,000 data points. USB 1.0 Interface Rain Gauge Specifications Mechanical Dimensions 12 wide x 17 high x 2.5 deep (30 x 43 x 6 cm) Weight Composition Aluminum Specifications are subject to change without notice Labelled diagram of a Driving Rain Gauge Environmental Operating Temperature Storage Temperature Humidity Electrostatic Discharge (ESD) 0 to 40C / 32 to 104F -25 to 70C / -13 to 158F 5% to 100% RH non-condensing 8kVdc air, 4 kvdc contact (exposed inputs) Safety/Regulatory Safety Requirements Regulatory SELV Separated Extra Low Voltage Contains FCC ID: OA3MRF24J40MA This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Contains IC: 7693A-24J40MB Website: www.smtresearch.ca Email: info@smtresearch.ca RS-1119 Rev 01

Installation Preparation Structure Monitoring Technology 1. Avoid locations where trees or plantings could potentially drop leaves, debris, etc. causing the drain system to be blocked. 2. Use signage or other acceptable methods when the Driving Rain Gauge is used near grade, balconies, or windows so that objects are not deposited into the gauge, causing readings to be inaccurate Procedure There are 3 fastening locations provided on the Driving Rain Gauge. Rain Gauge with cover closed and open. When open, 3 fastening locations are available Close-up of opened cover and right side thumb-screw. 1. The top centre location should be attached first, but not fully tightened 2. The unit can be levelled using a level and the 2 nd and 3 rd fasteners installed through the tipping bucket area of the gauge. It is accessed by loosening the thumb-screw on the lower right side of the unit and folding open the cover. 3. The top fastener can then be fully tightened. (The wiring for the unit can be run out of the back of the unit straight through the wall or down the exterior of the wall.)

Programming 1. The SMT A2 Pulse Datalogger is used to monitor tipping bucket transitions. 2. The A2 will report accumulated pulses in the interval set by the Building Intelligence Gateway (BiG). Typical sample time is 1 hour. 3. Each switch closure of the standard Driving Rain Gauge is signalled by a measurement of 5.44cm 3 (0.33in 3 ) of water from a given 929cm 2 (144in 2 ) catchment area which corresponds to 0.059mm (0.002in) of driving rain on the vertical wall surface. A2 s set to read pulse counts are equipped in an outdoor enclosure. Connect the NEMA enclosure to the Driving Rain Gauge as shown below. Cut the supplied RJ11 wire as required and connect to the A2 as shown below. (This image is looking at the top of the A2 unit.) Polarity is not important. The yellow and green wires are connected together. The Menu button on the A2 is not present. To take a reading, press the Select button once to wake up the screen and another time to select measure. The unit will automatically join the network when connected. Maintenance 1. Cleaning and verification is required only at the time of installation and annually thereafter. If the gauge is installed in an area with known airborne debris, it is suggested to monitor it and determine an appropriate maintenance schedule. 2. To verify performance, slowly pour approximately 50mL (1.7oz) of water into the Driving Rain Gauge and simultaneously monitor the number of switch closures recorded by the A2 Pulse Counter unit. If the proper number is not recorded, the test should be repeated. After 2 incorrect results, the logging system and wiring should be investigated for continuity and to make sure the system is reading at the correct frequency to record the switch closure signal.

Pulse Counter Configuration in BiG Select the A2 and right click on sensor input 5 and select Configure. Under the sensor type Custom select Quadratic Equation. Enter 0.058 for the x value as shown below. Each tip contains 5.44mL. On a 12 x12 surface area (144in2 = 929cm2) that would be 0.058 mm of rainfall onto the vertical surface of the rain gauge. As noted, the Menu key on Pulse units is not present as the pulse counting was routed to the internal interrupt port previously used by the switch. In order to clear the log of a pulse unit the following actions will need to be performed: Enable the superuser menu in BiG. Select the directory where the BiG database is stored. Windows Vista/7/8 -> C:\ProgramData\BiG\ Create a file called superuser with no extension. You may need to select Hide Known File Types in Folder Options Under Devices double click on the I3. Enter the NodeID of the A2 into the box under Logs that you wish to zero. Select Erase. WARNING: No confirmation is shown when this is selected. Once the A2 responds (within 5 minutes or immediately if measure selected) the Log will be erased.