Practical course in scanning electron microscopy

Similar documents
object objective lens eyepiece lens

Praktikum zur. Materialanalytik

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Electron Microprobe Analysis 1 Nilanjan Chatterjee, Ph.D. Principal Research Scientist

Transmission Electron Microscopy

Gaetano L Episcopo. Scanning Electron Microscopy Focus Ion Beam and. Pulsed Plasma Deposition

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

High-Resolution. Transmission. Electron Microscopy

= 6 (1/ nm) So what is probability of finding electron tunneled into a barrier 3 ev high?

AP5301/ Name the major parts of an optical microscope and state their functions.

Modern Optical Spectroscopy

Why microscopy?

Scanning Electron Microscopy

Electron Microprobe Analysis and Scanning Electron Microscopy

4. Inelastic Scattering

M2 TP. Low-Energy Electron Diffraction (LEED)

Weak-Beam Dark-Field Technique

Chapter 9. Electron mean free path Microscopy principles of SEM, TEM, LEEM

Chemical Analysis in TEM: XEDS, EELS and EFTEM. HRTEM PhD course Lecture 5

X-RAY SPECTRA. Theory:

Basic structure of SEM

Part I Basics and Methods

Analytical Methods for Materials

EDS User School. Principles of Electron Beam Microanalysis

QUANTUM PHYSICS. Limitation: This law holds well only for the short wavelength and not for the longer wavelength. Raleigh Jean s Law:

6. Analytical Electron Microscopy

Part II: Thin Film Characterization

h p λ = mν Back to de Broglie and the electron as a wave you will learn more about this Equation in CHEM* 2060

The Basic of Transmission Electron Microscope. Text book: Transmission electron microscopy by David B Williams & C. Barry Carter.

Electron Microscopy I

CHEM 681 Seminar Mingqi Zhao April 20, 1998 Room 2104, 4:00 p.m. High Resolution Transmission Electron Microscopy: theories and applications

Scanning Electron Microscopy & Ancillary Techniques

SEM stands for Scanning Electron Microscopy. The earliest known work describing

An Introduction to Diffraction and Scattering. School of Chemistry The University of Sydney

MT Electron microscopy Scanning electron microscopy and electron probe microanalysis

SEM Doctoral Course MS-636. April 11-13, 2016

Advanced Lab Course. X-Ray Photoelectron Spectroscopy 1 INTRODUCTION 1 2 BASICS 1 3 EXPERIMENT Qualitative analysis Chemical Shifts 7

Electron probe microanalysis - Electron microprobe analysis EPMA (EMPA) What s EPMA all about? What can you learn?

Chapter 10: Wave Properties of Particles

Ecole Franco-Roumaine : Magnétisme des systèmes nanoscopiques et structures hybrides - Brasov, Modern Analytical Microscopic Tools

CHARACTERIZATION of NANOMATERIALS KHP

XRF books: Analytical Chemistry, Kellner/Mermet/Otto/etc. 3 rd year XRF Spectroscopy Dr. Alan Ryder (R222, Physical Chemistry) 2 lectures:

Invited Lecture. "Different Aspects of Electron Microscopy. Sardar Vallabhbhai National Institute of Technology, Surat. Deepak Rajput & S.K.

Chemistry Instrumental Analysis Lecture 19 Chapter 12. Chem 4631

Everhart-Thornley detector

Massachusetts Institute of Technology. Dr. Nilanjan Chatterjee

Chapter 37 Early Quantum Theory and Models of the Atom

SEM Optics and Application to Current Research

Chapter 37 Early Quantum Theory and Models of the Atom. Copyright 2009 Pearson Education, Inc.

HOW TO APPROACH SCANNING ELECTRON MICROSCOPY AND ENERGY DISPERSIVE SPECTROSCOPY ANALYSIS. SCSAM Short Course Amir Avishai

FXA UNIT G485 Module X-Rays. Candidates should be able to : I = I 0 e -μx

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

MSE 321 Structural Characterization

Physical Principles of Electron Microscopy. 2. Electron Optics

Interaction X-rays - Matter

X-ray spectroscopy: Experimental studies of Moseley s law (K-line x-ray fluorescence) and x-ray material s composition determination

Generation of X-Rays in the SEM specimen

Basic physics Questions

SOLID STATE PHYSICS PHY F341. Dr. Manjuladevi.V Associate Professor Department of Physics BITS Pilani

Lecture 22 Ion Beam Techniques

Transmission Electron Microscope. Experimental Instruction

Introduction to Electron Microscopy Andres Kaech. Instrumentation

Röntgenpraktikum. M. Oehzelt. (based on the diploma thesis of T. Haber [1])

Radioactivity. Lecture 6 Detectors and Instrumentation

April 10th-12th, 2017

X-ray Absorption Spectroscopy

MSE 321 Structural Characterization

EEE4106Z Radiation Interactions & Detection

ECE Semiconductor Device and Material Characterization

Photoemission Spectroscopy

MARKING SCHEME SET 55/1/MT Q. No. Expected Answer / Value Points Marks Total Marks. Section A

Overview of scattering, diffraction & imaging in the TEM

Telescopes: Portals of Discovery

Lecture 5. X-ray Photoemission Spectroscopy (XPS)

Nano-Microscopy. Lecture 2. Scanning and Transmission Electron Microscopies: Principles. Pavel Zinin HIGP, University of Hawaii, Honolulu, USA

Ma5: Auger- and Electron Energy Loss Spectroscopy

MANIPAL INSTITUTE OF TECHNOLOGY

Analysis of γ spectrum

MSE 321 Structural Characterization

tip conducting surface

X-RAY PRODUCTION. Prepared by:- EN KAMARUL AMIN BIN ABDULLAH

Atomic Spectra HISTORY AND THEORY

CHAPTER 3 The Experimental Basis of Quantum Theory

Electron beam scanning

UNIT-III QUANTUM PHYSICS

PHYS 4 CONCEPT PACKET Complete

Auger Electron Spectroscopy Overview

Characterisation of Catalysts Using Secondary and Backscattered Electron In-lens Detectors

Phys102 Lecture Diffraction of Light

CHEM*3440. X-Ray Energies. Bremsstrahlung Radiation. X-ray Line Spectra. Chemical Instrumentation. X-Ray Spectroscopy. Topic 13

Structure analysis: Electron diffraction LEED TEM RHEED

Conventional Transmission Electron Microscopy. Introduction. Text Books. Text Books. EMSE-509 CWRU Frank Ernst

X-ray Spectroscopy. Danny Bennett and Maeve Madigan. October 12, 2015

Engineering Physics 1 Prof. G.D. Vermaa Department of Physics Indian Institute of Technology-Roorkee

Auger Electron Spectroscopy (AES) Prof. Paul K. Chu

Shell Atomic Model and Energy Levels

Scintillation Detector

Photoelectron spectroscopy Instrumentation. Nanomaterials characterization 2

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

X Rays & Crystals. Characterizing Mineral Chemistry & Structure. J.D. Price

Transcription:

Practical course in scanning electron microscopy Fortgeschrittenen Praktikum an der Technischen Universität München Wintersemester 2017/2018

Table of contents 1. Introduction 3 2. Formation of an electron beam 5 3. Lens aberrations 6 4. Interactions of electrons with matter 8 5. Transmission electron microscope (TEM) 10 6. Scanning electron microscope (SEM) 12 6.1 Depth of field 17 7. Detectors 18 7.1 Detection of secondary electrons 18 7.2 Detection of backscattered electrons 19 7.3 Detection of X-rays 20 8. Experiment 21 9. Evaluation of your work 22 10. References 23 2

1. Introduction Microscopes are used in many fields of science to probe beyond the limits of sight. The human eye is able to distinguish two points as separate when the distance between them is at least 0.2 mm. The resolution can be improved using magnifying lenses or whole systems of these, i.e. optical microscopes. Unfortunately there exists a resolution limit for optical microscopes based on the wavelength of light. The smallest distance d between two points which can be resolved is given by the Rayleigh criterion: d = 0.61 λ n sin α With: λ: the wavelength of the light, α: the semi-angle of collection of the lens, n: the refractive index of the viewing medium The wavelength of visible light is about 400 nm for blue light and 720 nm for red light. The resolution which can be reached is therefore about 200 nm equivalent to a magnification of 1000. To improve resolution further, smaller wavelengths are needed. For doubling the resolution, ultra violet light can be used. A further increase of the resolution requires electron beams. In this practical course we are dealing with electron microscopy with a focus on scanning electron microscopy. Due to the wave-particle duality the wavelength λ of an electron beam can be calculated with the well-known de-broglie equation: λ = h p. With: p: the momentum h: the Planck constant 3

The wavelength depends on the electron momentum after acceleration in an electrostatic field. The momentum is: p = 2m e U as E kin = eu = p2 With: e: the elementary charge U: the accelerating voltage. This gives for the wavelength: λ = h 2m e U. At high electron velocity (which is the case at high voltages) a relativistic correction is needed: 2m λ = h 2m e U (1 + eu. 2m 0 c 2) With: m 0 : the rest mass of the electron, c: the light velocity The relativistic correction is necessary at voltages greater than above 80 kv. Typical voltages used in scanning electron microscopes are between 1 kv and 30 kv. In this course the student will operate such a microscope. In a transmission electron microscope higher voltages of 100 kv to 300 kv are used. With the above equation we can calculate that for an accelerating voltage of 100, 200, 300 kv we get a wavelength of 3.9, 2.7, 2,2 pm giving a 100 000 smaller wavelength than light. Inserting into the Rayleigh criterion a resolution of down to 0.2 nm can be theoretically reached with electron microscopy. The aim of this course is to acquaint students with electron microscopy with a focus on scanning electron microscopy. There are mainly two different types of electron microscopes: the transmission electron microscope and the scanning electron microscope. The way these two microscopes work is fundamentally different. First a short introduction to transmission 4

electron microscopy is given followed by an introduction to scanning electron microscopy. In the practical course the students will learn to operate a scanning electron microscope and to interpret the images. 2. Formation of an electron beam For creating an electron beam an electron source and an electrical potential for accelerating the electrons are required. The source is a cathode producing electrons by either thermionic emission or field emission. The electrons are accelerated by the electric field between the cathode and the anode. Between the cathode and the anode a cylinder with an aperture, the so called Wehnelt cylinder, is situated, see Fig.1. This cylinder is set on a negative electrical potential shaping the electron beam to pass the aperture and being further accelerated. The electrical field from the Wehnelt cylinder focuses the electrons into a crossover, which is the virtual electron source for the lenses in the electron microscope illumination system. The electron beam is scattered on gas molecules when the pressure is not low enough and becomes wider in diameter. This reduces the imaging quality. The needed pressure in the gun depends on the type of filament. For stabile operation of the electron beam the vacuum should be better than 10-4 mbar. In order to be able to image the nanostructure of the sample the electron beam needs to be further shaped. As the electrons are negatively charged, this is done using electrostatic and magnetic fields. In a transmission electron microscope higher magnification is reached (analogous to the optical microscope lenses) lenses which are electromagnets (often arranged in a quadrupole). In a scanning electron microscope the lenses are used to form a focused e- beam. The lenses are not used for imaging. The image quality suffers in both types of microscopes from lens aberration. In the following the three most relevant lens aberrations are described. 5

Fig.1: Schematic view of a thermionic electron gun. A high voltage is applied between the cathode and the anode. The electrical potential of the Wehnelt cylinder shapes the electron beam. The electrical field from the Wehnelt cylinder focuses the electrons into a crossover, which is the virtual electron source for the lenses in the electron microscope illumination system. [4] 3. Lens aberrations As in optical microscopes the resolution of the image is limited by aberrations and therefore the theoretically possible resolution of 0.2 nm is hard to reach in practice. Some shortcomings of the lenses can be corrected, others can be at least minimized. A summary of the three most important defects is given in the following: Chromatic aberration: The refractive index of a lens always has a small wavelength dependence with different wavelengths having different focal lengths. This effect is called chromatic aberration (Fig. 2). The wavelength of the incident electron beam varies due to the thermal Boltzmann energy distribution. These differences can be neglected. Therefore chromatic aberration does not play an essential role in a scanning electron microscope. In a transmission microscope, where the electrons pass through a thick foil (the sample) chromatic aberration can play a role. Fig.2: Lens with chromatic aberration: Different colors, i.e. different wavelength have different foci. [5] Astigmatism: Astigmatism (Fig. 3) occurs if the focal lengths are different for perpendicular planes of the incident beam. This defect originates from limitations in manufacturing perfectly cylindrically symmetric pole pieces or/and due to not perfectly centered beam- limiter- apertures. It can also originate from external electrical field. Fortunately astigmatism can be easily corrected using stigmators. These are octupoles which create a compensating electric field. It is 6

necessary to correct the image for astigmatism before taking images with an electron microscope. Fig.3: Lens with astigmatism. [6] Spherical aberration: Spherical aberration (Fig. 4) is a lens defect focusing off-axis rays differently than on-axis rays. This lens defect cannot be corrected. It can be only minimized by centering the lenses and by limiting off axis beam rays by apertures. Fig.4: Lens with spherical aberration and with focal length F. Off axis beam are focused at different focal lengths f1, f2, f3. [5] These limitations of lenses described above are the most relevant ones for electron microscopy. 4. Interaction of electrons with matter An electron beam incident on matter interacts in several ways. Electrons can be elastically and inelastically scattered in forward and backward directions. They can be absorbed or they can induce X-ray emission. Scattering in the forward direction is used in transmission electron microscopes and scattering in the backward direction is used in scanning electron microscopes. 7

Fig 5: showing an overview of the different signals being used in modern electron microscopes. The direction shown for each signal does not always represent the physical direction. [7] Fig.6: Above image gives an idea about the signal depth of the different signals. [5] Electron scattering can be divided into elastic and inelastic scattering. A collision is called elastic if there is no energy loss or the energy loss is negligible compared to the incident energy and only the flight direction of the electrons is changed. Inelastic scattering means the electrons lose energy. The scattering of an electron at an atomic nucleus is elastic if the energy loss in this scattering event is small (<1 ev) compared to the primary beam energy which is of the order of 30-100 kev. Scattering events in which the incident electrons loose energy and change the flight direction are inelastic. All interactions between the incident electrons and core electrons of sample atoms are inelastic. Secondary electrons, auger electrons, cathodoluminescence, characteristic X-rays are a result from inelastic interactions. Considering the electron beam as a wave we can separate the scattered electrons into coherently and incoherently scattered electrons. Elastically scattered electrons in forward direction are usually coherent. Inelastically scattered electrons are incoherent. The incident beam can be assumed to be coherent, that means the incident electron waves are in phase with each and have a fixed wavelength given by the acceleration voltage. Coherently scattered electrons are those remaining in phase. The intensity of elastic coherent scattering is highest at relatively low angles (1-10 ) in the forward direction. 5. Transmission electron microscope (TEM) The elastic, coherent scattering of electrons in forward direction is used in transmission electron microscopy. The electron beam passes through a thin sample and the transmitted electrons are detected. This is analogous to an optical microscope where the light passes through the sample and produces the image, see Fig. 7. By changing of the current in an electromagnetic lens its focal length is changed resulting in different magnifications. The switching of lenses as in an optical microscope to get different magnifications is therefore 8

not required. As the wavelength of the electron beam is of the order of the distance between two atomic planes the specimen acts as a diffraction grating. Therefore a diffraction pattern or an image of the specimen can be recorded. Depending on the adjustment of the lenses the diffraction pattern or the image of the sample can be observed. By observing the diffraction pattern the crystallinity and crystal orientation of the sample can be investigated. By observing the image the microstructure of the sample can be studied. The dominating contrast in TEM is the diffraction contrast, i.e. the contrast arising due to different crystallographic orientations. Fig. 7 shows schematically a light and transmission electron microscope. One can easily see the similarity between a light and a transmission electron microscope. Fig. 8 shows a scanning electron microscope. By comparing the set-up of a transmission electron microscope and a scanning electron microscope it is clear that a scanning electron microscope works fundamentally different from the way a transmission electron microscope works. In a classical transmission electron microscope the electron beam is parallel. When the electron beam is focused and is scanned point by point through the samples the microscope is a scanning transmission electron microscope. Fig.7: Overview of an optical microscope and a transmission electron microscope. [8] Fig.8: Overview of a scanning electron microscope. [9] 6. Scanning electron microscope (SEM) In a SEM the incident beam is not transmitted through the sample but the surface is scanned point by point by a focused electron beam. The focused electron beam is shaped by electromagnetic lenses. The image observed is not a direct image given by the incident electrons like in a TEM (by transmitting the sample), it is an image which results from the interaction between the incident beam and the sample surface. When the incident electron 9

beam hits the sample secondary and backscattered electrons are produced. Backscattered electrons are electrons which were backscattered at the sample s atoms and secondary electrons are electrons which were ejected from the atom shell by the incident electron beam. The image on the computer screen shows at each point the number of electrons which are counted in the detector, encoded in brightness, produced at the corresponding scanned point on the sample by the electron beam. The electron beam is deflected by electric fields to scan the sample surface point by point. By detecting the signal resulting from the interaction between the electrons and the sample surface the image is obtained point by point. Different magnifications are obtained by changing the current in the deflection coils. By decreasing the scanned area while keeping the number of scanned points constant a higher magnification is reached. Note that higher magnifications are obtained by scanning smaller areas of the sample and not by higher magnification through electromagnetic lenses. This is totally different comparing to the above explained TEM. For imaging in a SEM the signals from backscattered and secondary electrons can be used. The probability of a scattering event taking place is given by the cross section σ. The larger the cross section the more likely scattering occurs. The total cross section σ is the sum of the cross sections for elastic collision events σ el and inelastic events σ in. The three most important signals in a SEM are secondary electrons, backscattered electrons and X-ray emission. All these three signals will be used in this practical training. The image can be formed either by detecting the backscattered electrons (BSE) or by detecting the secondary electrons (SE) or a combination of them. Backscattered electrons are electrons which were at least once elastically scattered at the sample s atoms. The probability of an elastic event is given by the cross section for elastic scattering σ el. σ el depends on the incident electron energy σ el ~ 1 E2. The elastic cross section 0 decreases with increasing energy. Therefore at high acceleration voltages elastic scattering is infrequent and hence electrons are penetrating deeper into the sample. The elastic cross section also depends on the atomic number of the analyzed sample and is proportional: σ el ~Z 2. With increasing Z the incident electrons are more frequently scattered. With 10

increasing Z the scattering angle also increases so at higher Z the incident electrons have a smaller penetration depth and a larger exit width, compare Fig. 9. Altogether the elastic cross section can be written as σ el ~ Z2 E 0 2 1 sin 2 θ/2. In consequence this allows to gain some information about the composition of the sample. If a sample consists of two different phases with different Z, then the high Z material will appear brighter in the BSE image than the low Z material as more electrons are scattered in the high Z material compared to the low Z material. This contrast is called Z-contrast. Fig. 9: shows the dependence between the interaction volume of the electron beam (EB) and the acceleration voltage and the material atomic number Z. [10] The second signal used for taking images are the secondary electrons. The secondary electrons are orbit electrons ejected by incident electrons or by already backscattered electrons. The production of secondary electrons is an inelastic scattering event, i.e. the incident electrons are losing energy and changing their direction. The cross section for the production for SE is increasing with decreasing energy of the incident electrons and depends not on Z. Secondary electrons have low energies. By definition all electrons with energies below 50 ev are called secondary electrons. Because of the low energy only secondary electrons produced close to the surface at depths below 50 nm can exit the sample and can be detected. As the secondary electron signal originates only from depths up to 50 nm its intensity mostly depends on the topography of the sample surface giving a high quality image of the surface structure. When a surface is tilted towards the incident electron beam the volume from which secondary electrons can exit the sample is larger giving more signal, i.e. the tilted surface appears brighter, see Fig. 10. This is also the case at edges and needles, which appear brighter in the image. SE images appear like illuminated from the side because normally the SE detector is placed at a large angle and acts like a light source, giving a good topography contrast and making the images intuitive. To interpret SE images correctly it is important to know from which side the SE detector looks on the sample. 11

Fig. 10: SE production as a function of the incident angle of the beam electrons (EB). [10] When analyzing the images, it is important to remember that incident electrons can undergo several elastic and inelastic collisions before reaching the surface and being detected. Therefore electrons will not have discrete energies but rather an energy distribution as shown in Fig. 11. All electrons with an energy >50 ev are called backscattered by definition because they were at least once elastically backscattered. Electrons with energy E close to the primary incident energy E 0 were backscattered exactly once. Electrons with an energy between 50 ev and the primary energy (50 ev < E < E 0 ) underwent inelastic scattering events in addition to backscattering. Fig. 11: Energy distribution of the BSE and SE leaving the sample surface. [10] A very important signal used in a SEM is the characteristic X-ray emission which allows obtaining some information about the chemical composition of the sample. To characterize the chemical composition of the sample X-ray spectroscopy is used. This method is based on an interaction between the incident electrons and the sample s atoms: the characteristic X- ray emission. An incident electron can eject an electron from an inner atomic shell; say K, L or M leaving a vacancy in this shell. This vacancy is then filled by an outer shell electron and X-rays are emitted with an energy equivalent to the energy difference between the higher and lower energy state, see Fig. 12. The expression characteristic X-ray emission originates from the fact that the energy of the X-ray radiation is characteristic for each chemical element: This enables the identification of the chemical composition of the sample. The energy depends on the atomic number Z given by the Moseley law: E = [C 1 (Z C 2 )] 2 with E the energy of the X-rays, Z the atomic number and C1, C2 constants. The emitted X-rays are named after the chemical element and the electron transition between the two atomic shells. For example the transition from the L to the K shell in Cu is called Cu-Kα. From M to K it is called Cu-Kβ. The roman capital marks the shell from which the electron was ejected, the greek character gives the shell distance between the higher energetic shell and the lower energetic shell (α for a transition from the next higher shell, β from the second higher shell). In X-ray spectroscopy the spectroscopic lines from the K, L 12

and M shells are most often used. The Kα and Kβ lines are very useful as their intensities are high. Fig. 12 shows a typical X-ray spectroscopy spectrum. There are two kinds of the X-ray spectroscopy depending on the spectrometers used. If the spectrometer measures the wavelength of the X-ray radiation it is called wavelength dispersive spectrometry WDX. If the energy is measured it is called energy dispersive X-rays analysis EDX. In this course EDX will be used. An EDX spectrum (Fig. 12) contains not only characteristic X-ray radiation but also X-ray radiation resulting from the deceleration of the electrons in the electrostatic potential of the atoms. This is called Bremsstrahlung and is visible as background in the X-ray spectrum. Fig.12: schematic view of the origin of characteristic X-ray radiation [11] (right). Example spectrum (left)[12]. 6.1 Depth of field in SEM images Besides the excellent resolution of SEM images the high depth of field of SEM images is a further advantage. The depth of field describes the depth ranges where the image is in focus. The depth of focus D depends on the magnification M, d the resolution limit of the eye and α the angular aperture of the objective lens for the ideal case of no lens defects and an electron beam with no diameter. D = d/mα When taking into account the diameter of the beam d b the depth of field is: D = d M d b α The high depth of field of SEM images results from the very small angle α as the electron beam is focused. Because of the high depth of field of SEM images rough surfaces can be imaged well giving a 3D impression of the topography. 13

7. Detectors 7.1. Detection of secondary electrons For the detection of secondary electrons an Everhart-Thornley detector (scintilatorphotomultiplier detector) is used. Usually it is mounted at an angle of about 45 from the incident beam direction and has a collector mesh. Between the sample and the detector collector mesh a potential (of about 50 V) is applied which sucks the low energetic secondary electrons towards the detector. Due to this attractive potential the effective solid angle for detection of secondary electrons is large as electrons originating from the far side of the sample also reach the detector. After reaching the detector mesh the electrons are further accelerated by an inner potential towards the scintillator where they generate light signals. These light signals are then conducted through an optical fiber to the photomultiplier. In the photomultiplier the light signal is converted in electrons and these electrons are multiplied. This signal is used by the electronics to generate the image. The Everhart-Thornley detector also detects backscattered electrons. As these electrons have high energies the additional potential between the sample and the mesh hardly influences them. Therefore only backscattered electrons exiting the sample towards the detector can reach the detector. This results in a very small solid angle. Therefore when the attractive potential is turned on the number of the detected BSE is negligible in comparison to the number of detected SE. Of course the Everhart-Thornley detector can be also used to record a BSE image. To prevent secondary electrons reaching the detector an inverse potential of -50 V between the sample and the mesh can be applied. In that case the signal originates only from backscattered electrons, the secondary electrons are suppressed. As the solid angle for the detection of backscattered electrons is small the BSE image is noisy. 14

7.2. Detection of backscattered electrons To get high quality BSE images usually different types of detectors are used. Typically a semiconductor detector is used. A semiconductor detector is a diode biased reversed. The basic module of a semiconductor diode is the junction between a n-doped semiconductor and a p-doped semiconductor or a junction between a metal and a semiconductor. When biasing in inverse direction such a diode a depletion layer is formed. When the electrons reach the depletion layer they generate a number of electron-hole pairs which create a current pulse. This current pulse is then amplified and measured. BSE detectors are often located above the sample having a large opening to ensure a large solid angle for the BSE detection. To enable small working distances usually the BSE detector is mounted close below the end of the SEM column (pole piece). It is circular with a hole for the incident electron beam. This position is called high take-off angle. At this position the Z- contrast is excellent and the topography contrast is suppressed. Sometimes there is an additional BSE detector at a smaller angle or the BSE detectors can be tilted to that angle in order to get a better BSE topography contrast. This position is called low take -off angle. A BSE detector usually is either a semiconductor detector or scintillator-photomultiplier detector. A semiconductor BSE detector located at the high take-off position is often divided into several segments. The signals from each segment can be add or subtracted. With this the contrast can be influenced giving a better topography image or Z-contrast. 15

7.3. Detection of X-rays A classical semiconductor detector for EDX is a silicon semiconductor crystal. As in the X-ray spectroscopy the energy of photons is to be measured and these energies are in the order of a few kev it is important to minimize the background signal. Therefore only crystals with a high chemical purity and a low number of intrinsic crystal defects are used. To minimize further the conductivity the EDX detector is cooled with liquid nitrogen. When a photon reaches the depletion area it generates a number of electron-hole pairs which create a current pulse. As the energy needed to create an electron-hole pair in Si is 3.8 ev the number of created electron hole pairs by a photon is large. The energy of the electrical pulse is equal to the energy of the incoming X-ray. The electrical pulses are sorted by height in a multichannel analyzer which allows determining the X-ray energy giving the spectrum shown in Fig. 10. 16

8. Experiment First get acquainted with the microscope: look into the vacuum chamber, try to identify the different detectors, think about the geometry. You should use gloves. Sample 1: Observation of a screw and a coil filament Exercise 1: Try to take images in the SE mode and BSE mode To take an image: Check the cross over: if it is not in the middle of the axis move it there. Adjust brightness/contrast. Focus roughly your image. Recheck the cross over in the image Focus your image in a high magnification. When the sample is in focus click Z <-> FWD to tell the microscope that the sample is focused Check whether there is astigmatism; if so try to correct the astigmatism by adjusting the stigmator settings. Take your images in the SE mode. Switch to the BSE mode. Adjust contrast/brightness. Take some images. Exercise 2: Record an EDX spectrum and identify the elements with the EDAX Genesis software Start the program EDAX Genesis and collect the spectrum by clicking button Collect. Identify the peaks with Peak ID and consider whether the peak identification by the program is correct. Identify all peaks. Sample 2: pyramid W on Fe sample Exercise 1: Take SE images of the sample and BSE images. How to make topography contrast with BSE? Make a topography contrast BSE image. Exercise 2: Rotate with scan rotation and consider how to identify Berge und Täler Sample 3: polished sample Exercise 1: Take SE and BSE images. What do you learn from this? What do you see? Exercise 2: Take an EDX spectrum. 17

Sample 4: unknown sample Exercise 1: Take SE image and BSE (A+B), (A-B) and record an EDX spectrum. Why are the images so different? 9. Evaluation Sample 1: Show your images. Sample 2: Explain the differences between a SE and BSE image and a topography BSE image. Explain how to see topography with the BSE detector. Discuss how to identify rough surface. How do you see which part of the sample is higher. Discuss the scan rotation and why you should be very careful when interpreting the images. Sample 3: Explain how to distinguish in a BSE image whether you see material contrast or something else. Evaluate the taken EDX spectra and identify the element/elements on the sample. Describe your procedure in identifying the peaks. Sample 4: Evaluate the taken EDX spectra and identify the element/elements on the sample. Please add the taken images and EDX spectra to your evaluation. 18

10. References: [1] Peter Fritz Schmidt et al.: Praxis der Rasterelektronenmikroskopie und Mikrobereichsanalyse, 1994, expert verlag, Renningen-Malmsheim [2] Andrzej Barbacki: Mikroskopia elektronowa, 2007, Wydawnictwo Politechniki Poznanskiej, Poznan [3] David B. Williams, C. Barry Carter Transmission Electron Microscopy part 1 basics, 1996, Springer Science+Business Media, New York Images references: [4] https://lp.uni-goettingen.de/get/text/353 [5] wikipedia.de; wikipedia.org, wikipedia.pl [6] https://www.onlinesehtests.de/astigmatismus/ [7] David B. Williams, C. Barry Carter Transmission Electron Microscopy part 1 basics, 1996, Springer Science+Business Media, New York [8] http://wiki.polymerservice-erseburg.de/index.php/transmissionselektronenmikroskopie [9] http://www.technoorg.hu/news-and-events/articles/high-resolution-scanning-electronmicroscopy-1/ [10] Peter Fritz Schmidt et al.: Praxis der Rasterelektronenmikroskopie und Mikrobereichsanalyse, 1994, expert verlag, Renningen-Malmsheim [11] http://geo-consulting.warnsloh.de/rfaxrf-allgemein/ [12] Andrzej Barbacki: Mikroskopia elektronowa, 2007, Wydawnictwo Politechniki Poznanskiej, Poznan 19