W. A. D. M. Weragoda and N.T. Medagedara

Similar documents
Analytical Solution of Magnetic Field in Permanent-Magnet Eddy-Current Couplings by Considering the Effects of Slots and Iron-Core Protrusions

Keywords: Electric Machines, Rotating Machinery, Stator faults, Fault tolerant control, Field Weakening, Anisotropy, Dual rotor, 3D modeling

CHAPTER 8 CONSERVATION LAWS

Version The diagram below represents lines of magnetic flux within a region of space.

Doubly salient reluctance machine or, as it is also called, switched reluctance machine. [Pyrhönen et al 2008]

Definition Application of electrical machines Electromagnetism: review Analogies between electric and magnetic circuits Faraday s Law Electromagnetic

Analysis and Experiments of the Linear Electrical Generator in Wave Energy Farm utilizing Resonance Power Buoy System

Identification of Electron Cyclotron Resonance Heating (ECR) Surfaces in the UPPR-Plasma Device Operating in the Cusp and Mirror Mode.

Electromagnetism in finite element method

CHAPTER 7 ELECTRODYNAMICS

ANALYSIS OF FLUX DENSITY AND FORCE ON DOUBLE SIDED LINEAR INDUCTION MOTOR WITH DIFFERENT POLE SHAPES

DO PHYSICS ONLINE MOTORS AND GENERATORS FARADAY S LAW ELECTROMAGNETIC INDUCTION

Modelling, Simulation and Temperature Effect Analysis of Mutual Induction based High Temperature Level Sensor using COMSOL Multiphysics

Chapter 7. Electrodynamics

Experimental Assessment of Unbalanced Magnetic Force according to Rotor Eccentricity in Permanent Magnet Machine

Optimal Design of PM Axial Field Motor Based on PM Radial Field Motor Data

4 Finite Element Analysis of a three-phase PM synchronous machine

Presented at the COMSOL Conference 2010 Paris

COGGING torque is one of the major sources of vibration

1. Introduction. (Received 21 December 2012; accepted 28 February 2013)

Multiphysics Analysis of Electromagnetic Flow Valve

Fig. 2.1 I =... A [2] Suggest why it would be impossible for overhead cables carrying an alternating current to float in the Earth s magnetic field.

The initial magnetization curve shows the magnetic flux density that would result when an increasing magnetic field is applied to an initially

Electromagnetic Forces on Parallel Current-

AQA Physics A-level Section 7: Fields and Their Consequences

Dynamic simulation of a coaxial magnetic gear using global ODE's and DAE s and the rotating machinery, magnetic interface

DEHRADUN PUBLIC SCHOOL I TERM ASSIGNMENT SUBJECT- PHYSICS (042) CLASS -XII

Magnetic Force on a Moving Charge

Research of double claw-pole structure generator

Project 1: Analysis of an induction machine using a FEM based software EJ Design of Electrical Machines

338 Applied Electromagnetic Engineering for Magnetic, Superconducting, Multifunctional and Nano Materials

1 (a) Define magnetic flux [1]

IE1206 Embedded Electronics

ACCURACY ASSESSMENT OF THE LINEAR INDUCTION MOTOR PERFORMANCE USING ADAPTIVE FEM

Finite Element Model of a Magnet Driven Reed Switch

Electricity & Magnetism Study Questions for the Spring 2018 Department Exam December 4, 2017

Generators for wind power conversion

Lecture Notes ELEC A6

Sensibility Analysis of Inductance Involving an E-core Magnetic Circuit for Non Homogeneous Material

III.Sources of Magnetic Fields - Ampere s Law - solenoids

TAP 416-3: Alternating current generators

1 Fig. 3.1 shows the variation of the magnetic flux linkage with time t for a small generator. magnetic. flux linkage / Wb-turns 1.

IE1206 Embedded Electronics Le2

PHYSICS ASSIGNMENT ES/CE/MAG. Class XII

Tutorial: Theory and applications of the Maxwell stress tensor

Design and analysis of Axial Flux Permanent Magnet Generator for Direct-Driven Wind Turbines

A half submerged metal sphere (UIC comprehensive

Mass of neutron=1.675 X kg. SECTION-A

Texas A & M University Department of Mechanical Engineering MEEN 364 Dynamic Systems and Controls Dr. Alexander G. Parlos

Sliding Conducting Bar

1439. Numerical simulation of the magnetic field and electromagnetic vibration analysis of the AC permanent-magnet synchronous motor

Finite Element Method based investigation of IPMSM losses

A cylinder in a magnetic field (Jackson)

IEEE Transactions on Applied Superconductivity. Copyright IEEE.

Design and Modelling of Generator for Wave Energy Conversion System in Malaysia

Outer rotor eddy current heater for wind turbines

2. Electromagnetic Actuator Model. 1. Introduction. *Corresponding author: D Dresden, Germany,

ENGG4420 LECTURE 7. CHAPTER 1 BY RADU MURESAN Page 1. September :29 PM

ELECTRICALMACHINES-I QUESTUION BANK

Simulation of resonances in the homopolar generator

Application of the HES in Angular Analysis

Magnetic field and magnetic poles

Chapter 2 Basics of Electricity and Magnetism

ROEVER COLLEGE OF ENGINEERING & TECHNOLOGY ELAMBALUR, PERAMBALUR DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ELECTRICAL MACHINES I

Electric Field Mapping

Time-Harmonic Modeling of Squirrel-Cage Induction Motors: A Circuit-Field Coupled Approach

REVIEW SESSION. Midterm 2

Robust optimal design of a magnetizer to reduce the harmonic components of cogging torque in a HDD spindle motor

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

Part 11 - Physics Paper 2 Magnetism and Electromagnetism Combined Science Application Questions

PROBLEMS TO BE SOLVED IN CLASSROOM

Impact of the forces due to CLIQ discharges on the MQXF Beam Screen. Marco Morrone, Cedric Garion TE-VSC-DLM

Flux: Examples of Devices

Excerpt from the Proceedings of the COMSOL Conference 2010 Paris

Sure-shot questions for SA-2 (Class XII) Physics

Chapter 8. Conservation Laws. 8.3 Magnetic Forces Do No Work

AP Physics C. Magnetism - Term 4

Sensitivity Estimation of Permanent Magnet Flowmeter

2. When the current flowing through a wire loop is halved, its magnetic moment will become a. half. b. one-fourth. c. double. d. quadruple.

MAGNETIC PROBLEMS. (d) Sketch B as a function of d clearly showing the value for maximum value of B.

Effect of Reaction Plate on Performance of Single-Side Linear Induction Motor in Different Speeds and Frequencies with Finite Element Method

1103 Period 19: Magnetic Forces and Electromagnets

Analysis of Single Mode Step Index Fibres using Finite Element Method. * 1 Courage Mudzingwa, 2 Action Nechibvute,

Magnetic Quantities. Magnetic fields are described by drawing flux lines that represent the magnetic field.

FXA 2008 Φ = BA. Candidates should be able to : Define magnetic flux. Define the weber (Wb). Select and use the equation for magnetic flux :

MAGNETIC CIRCUITS. Magnetic Circuits

Physics (Theory) There are 30 questions in total. Question Nos. 1 to 8 are very short answer type questions and carry one mark each.

Different Techniques for Calculating Apparent and Incremental Inductances using Finite Element Method

Magnetostatic Analysis of Solenoid

Equal Pitch and Unequal Pitch:

Handout 10: Inductance. Self-Inductance and inductors

An ion follows a circular path in a uniform magnetic field. Which single change decreases the radius of the path?

Optimal Design of a Permanent Magnetic Actuator for Vacuum Circuit Breaker using FEM

BLUE-PRINT II XII Physics

Induction_P1. 1. [1 mark]

DESIGN AND ANALYSIS OF LIGHT WEIGHT MOTOR VEHICLE FLYWHEEL M.LAVAKUMAR #1, R.PRASANNA SRINIVAS* 2

UJET VOL. 2, NO. 2, DEC Page 8

EXPERIMENTAL DESIGN METHOD APPLIED TO THE OPTIMISATION OF A LINEAR EDDY CURRENT BRAKE.

Optimization Design of a Segmented Halbach Permanent-Magnet Motor Using an Analytical Model

Analytical Model for Sizing the Magnets of Permanent Magnet Synchronous Machines

Transcription:

Effect of Electromagnetic Force on the Design of a Linear Alternator W. A. D. M. Weragoda and N.T. Medagedara Department of Mechanical Engineering, The Open University of Sri Lanka, Nugegoda, Sri Lanka *Corresponding author: Email: wadmweragoda@gmail.com 1 INTRODUCTION Linear alternators are devices used to convert mechanical energy into electrical energy. Although linear alternators are used for high power generation, such as the free piston engine and the wave power generator, linear alternators that can be used for low power generation are not commercially available. This research focused on designing a linear alternator to suit low power generation needs. These low power linear alternators can be used to harness energy off exercise machines, with linear motion and even rotary motion via a crank-slider mechanism and thereby store energy in a battery for later use. Two main factors that have to be considered when designing a Linear Alternator are the total resistance and output voltage. The total resistance depends on the inertia force and the electromagnetic force of the system. With the variation in the dimensions of the linear alternator, and the arrangement of magnets and iron rings of the linear alternator, the Magnetic flux density takes a complex form (https:// www.supermagnete.de/eng/faq/how-do-youcalculate-the-magnetic-flux-density). The electromagnetic force acting on the translator is determined using COMSOL Multi-physics and the Maxwell s stress tensor to optimize the design. Several simulations were carried-out, analysed, and the method of approaching the optimum solution is presented. There are two main factors that affect the total resistance to motion; the inertia force due to the mass of the translator and the electromagnetic force due to the magnetic flux distribution. Determining the electromagnetic force is not as straight forward as determining the inertia force. It requires solving complex equations such as Maxwell s stress tensor, utilizing software such as COMSOL Multiphysics and carrying out mesh refinements processes in order to obtain an optimized solution (Bethany, 2017). 1.1 Electromagnetic force The electromagnetic force can be computed using two main methods, the Lorentz force and the Maxwell s Stress tensor. Since the translator is a magnetic material, Lorentz force method cannot be used to compute the force on the translator (Paudel, 2016) 1.2 Electromagnetic force calculation The electromagnetic force is obtained by using the Maxwell s Stress tensor given in equation 1 and 2 (Bermúdez et al., 2016). F = 2πrTnds (1) T ij = 1 μ 0 (B i B j 1 2 δ ijb 2 ) (2) ISSN 2012-9916 The Open University of Sri Lanka 107

T = Stress tensor n = unit normal vector B = Magnetic flux density (T) μ o = Permeability of Vacuum 4π 10 7 F = Electromagnetic force 1.3 Variation of magnetic flux with shape of the magnet B = B r 2 [ D + z R 2 a + (D + z) 2 z R 2 a + z ( D + z 2 R 2 i + (D + z) 2 z (3) R 2 i + z2)] Figure 1: Dimensions of the hollow cylindrical magnet 2 METHODOLOGY 1. Several linear alternator designs such as moving iron, moving magnet and moving coil were studied and the moving iron linear alternator was selected as the design because of its advantages. 2. The linear alternator was initially designed using manual calculation from equations obtained from research papers. (Ding Wang (2016)) 3. Parameters and dimensions of that design were varied and results were obtained using COMSOL Multiphysics and the results were analysed and changes were made in the design Iron Magnet The electromagnetic force (given in equation 1) depends on the magnetic flux density as shown by equation 2. Equations 3 shows that, the magnetic flux density varies with the dimension and the shape of the magnet. These equations were used to simulate the model and optimize the design using COMSOL Multiphysics. Figure 2 shows the 2D axis-symmetric drawing of the arrangement of the permanent magnets and irons incorporated in the linear alternator. Figure 3 shows the way the electromagnetic force varies with the size of the magnet. This uneven variation is due to the arrangement of magnets, i.e. the pole pitch of the alternator. The Remnant flux density of the magnets was kept constant and the size of iron and magnet was varied. When a magnet is kept near an iron, the iron is magnetized and a complex magnetic flux distribution is formed, this in turn results in the uneven variation of the electromagnetic force. Figure 2: Geometric model of alternator 108 ISSN 2012-9916 The Open University of Sri Lanka

Resistance / (N) Resistance to motion /(N) Voltage/(V) Electromagnetic Force (N) Proceeding of the 15 th Open University Research Sessions (OURS 2017) 60 20 10 Electromagnetic Force 9 14 19 24 29 34 Size of Magnet (mm) Figure 3: Variation of emf with size of magnet 90 80 70 60 25 23 21 19 Resistance (16mm) Resistance (17mm) Resistance (18mm) Voltage (16mm) Voltage (17mm) Voltage (18mm) 17 15 13 14 19 24 29 Shaft radius /(mm) Figure 4: Graph of variation of resistance and voltage with size of the shaft 20 y = 3.8489x - 8.7 8 13 Voltage /(V) y = 4.0242x - 12.797 18mm shaft 20 mm shaft Linear (18mm shaft) Linear (20 mm shaft) Figure 5: Graph of variation of resistance vs. voltage ISSN 2012-9916 The Open University of Sri Lanka 109

Figure 4, shows the variation of the resistance and voltage with the size of the shaft of the translator. When the diameter of the shaft is changed, the inner diameter of the magnet and the iron also change. This will also change the magnetic flux distribution around the magnet, and thus, the resistance to motion. The resistances and the voltages corresponding to the encircled shaft radii were further analysed and two shaft radii were selected. The variation of resistance and voltage of both the shafts (i.e. 18 mm and 20 mm) were plotted as shown in Figure 5. The gradient of the graph of resistance versus voltage for the linear alternator model with the 18 mm shaft is less than that of the 20mm shaft. This indicates that for a unit rise in voltage the unit rise in resistance for the model of 18mm shaft is less than that of the 20mm shaft. Thus, the most suitable design could be obtained if the 18mm shaft is used. Figure 6 and Figure 7 show the magnetic flux distribution and the output voltage of the final design of the Linear Alternator (LA). The simulation was performed at a translator speed of 1.4 ms-1. An output voltage of approximately 14.5V was produced at this pace. And this could be utilized to charge a battery of 12V. Figure 6: Magnetic Flux distribution of LA Figure 7: Output voltage LA at 1.4 ms -1 4 CONCLUSIONS AND RECOMMENDATIONS A 12V battery can be charged with an output voltage of 14.5V, as a 12V battery s float voltage is around 2.25 to 2.3 volts/cell (at 25 degrees C) (i.e. 13.5V to 13.8V for 12V battery). The total resistance depends on the inertia force and the electromagnetic force. The total resistance is around 42 N, which is considerably low. The optimization of the linear alternator was obtained using COMSOL Multiphysics, by selectively altering parameters and comparing the best possible values to suit the design. The electromagnetic force changes with the size of the permanent magnet, iron, alternator shaft and the arrangement of magnets. Further studies and optimization could be done by simultaneously linking MATLAB and COMSOL Multiphysics to determine the reason for the uneven variation of the resistance and to obtain better solutions. 110 ISSN 2012-9916 The Open University of Sri Lanka

REFERENCES Bethany, N. (2017). How to Implement a Mesh Refinement Study COMSOL Blog. COMSOL Multiphysics. Retrieved 29 June 2017, from https://www.comsol.com/blogs/howto-implement-mesh-refinement-study Bermúdez A., Rodrigues, A.L. and Villar, I. (2016). Extended Formulas to Compute Resultant and Contact Electromagnetic Force and Torque from Maxwell Stress Tensors - IEEE Journals and Magazine. [Online] Available from: http://ieeexplore.ieee.org/document/77 62235/ [Accessed 05 February 2017]. Calculate magnetic flux density with formula - supermagnete. Supermagnete.de. Retrieved 10 February 2017, from https://www.supermagnete.de/eng/faq/ How-do-you-calculate-the-magneticflux-density Ding Wang (2016). Linear alternator design for use in heat energy recovery system - IET Conference Publication. [Online] Available from: http:// ieeexplore.ieee.org/document/624218 8/ [Accessed 08 Feb. 2017]. Paudel, N. (2016). Part 1: How to Model a Linear Electromagnetic Plunger. COMSOL Multiphysics. Retrieved 17 February 2017, from https://www.comsol.com/blogs/part-1- how-to-model-a-linearelectromagnetic-plunger/ ISSN 2012-9916 The Open University of Sri Lanka 111