Experimental Study of Parallel Plate Fin Heat Sinks with and without Perforation on Circular Pin Fins between the Plate Fins

Similar documents
Experimental Analysis of Natural Convective Heat Transfer Performance From Rectangular Fin Array with Perforations

Experimental Study of Natural Convective Heat Transfer from Vertical Rectangular Fin Array at Different Angle of Inclination

Ali S. Sharbuddin, International Journal of Advance Research, Ideas and Innovations in Technology.

Experimental Analysis of Rectangular Fin Arrays with Continuous Fin and Interrupted Fins Using Natural and Forced Convection

Natural Convective Study of Heat Transfer from Plate-Finned Heat Sinks

Experimental Analysis of Natural Convection Heat Transfer from Smooth and Rough Surfaces

Natural Convection Heat Transfer inside a Narrow Triangular Enclosure with Rectangular Staggered Finned Base Plate: An Empirical Correlation

Study on Thermal Performance of Micro Fin Heat Sink under Natural Convection A Review

Computational Analysis of Inverted Notched Fin Arrays Dissipating Heat by Natural Convection

Performance of Elliptical Pin Fin Heat Exchanger with Three Elliptical Perforations

International Journal of Engineering Research and General Science Volume 3, Issue 6, November-December, 2015 ISSN

PHYSICAL MECHANISM OF NATURAL CONVECTION

THEORETICAL STUDY AND FINITE ELEMENT ANALYSIS OF CONVECTIVE HEAT TRANSFER AUGMENTATION FROM HORIZONTAL RECTANGULAR FIN WITH CIRCULAR PERFORATION

International Engineering Research Journal Experimental Investigation of Natural Convection Heat Transfer from Perforated Vertical Plate

Heat Transfer Enhancement of Solar Flat Plate Collector by Using V Corrugated Fins and Various Parameters

Heat Transfer Enhancement Through Perforated Fin

International Journal of Modern Trends in Engineering and Research e-issn No.: , Date: April, 2016

Thermal Performance Characterization of Embedded Pulsating Heat Pipe Radiators by Infrared Thermography

Experimental Analysis of Cooling Fins

An Experimental Study on Heat Transfer Enhancement of Flat Plates Using Dimples

FLUID FLOW AND HEAT TRANSFER INVESTIGATION OF PERFORATED HEAT SINK UNDER MIXED CONVECTION 1 Mr. Shardul R Kulkarni, 2 Prof.S.Y.

HEAT TRANSFER AND TEMPERATURE DISTRIBUTION OF DIFFERENT FIN GEOMETRY USING NUMERICAL METHOD

Experimental Analysis on Pin Fin Heat Exchanger Using Different Shapes of the Same Material

SIMULATION OF FIN GEOMETRIES FOR HEAT SINK IN FORCED CONVECTION FLOW

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online):

NATURAL CONVECTION HEAT TRANSFER FLOW VISUALIZATION OF PERFORATED FIN ARRAYS BY CFD SIMULATION

Review of Natural Convection from Rectangular Interrupted Fins.

Experimental Evaluation of Natural Convection Heat Transfer for Rough Surface

Numerical Investigation of Multijet Air Impingement on Pin Fin Heat Sink with Effusion Slots

A Numerical Study of Laminar Natural Convection Heat Transfer and Radiation from a Rectangular Vertical Fin Array Quasi-3D approach

Effect of Flow Condition and Base Contact Ratio of Perforated Array Fins on Heat Transfer Augmentation using Computational Fluid Dynamics technique

Experimental Investigation of Forced Convection Heat Transfer Augmentation from a Dimpled Surface

New Approach to the Heat Transfer through Pin Fin Heat Sink in Bypass Flow and Fin Optimization

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY

Journal of Engineering Research and Studies E-ISSN

Experimental Study of Convective Heat Transfer and Thermal Performance in the Heat-Sink Channel with Various Geometrical Configurations Fins

Comparative Analysis of Heat Transfer and Friction Characteristics in a Corrugated Tube

Analysis of Natural Convective Heat Transfer From Cylinder Having Rectangular Notched Fins

PROBLEM 9.3. KNOWN: Relation for the Rayleigh number. FIND: Rayleigh number for four fluids for prescribed conditions. SCHEMATIC:

EFFECT OF AN AXIAL HOLE ON NATURAL CONVECTION HEAT TRANSFER FROM A CYLINDRICAL PIN FIN ATTACHED TO A HORIZONTAL PLATE

Study on the natural air cooling design of electronic equipment casings: Effects of the height and size of outlet vent on the flow resistances

Study of Convective Heat Transfer through Micro Channels with Different Configurations

Effect of FinInclinationson Natural Convection Heat Transfer by using CFD

Maximum Heat Transfer Density From Finned Tubes Cooled By Natural Convection

Study of Effect of Fin Geometry on Rate of Heat transfer for a 150cc, 4-stroke IC Engine

Iterative calculation of the heat transfer coefficient

Heat Transfer Characteristics of Square Micro Pin Fins under Natural Convection

Effect of roughness shape on heat transfer and flow friction characteristics of solar air heater with roughened absorber plate

An experimental study on heat transfer for a tilted semi-cylindrical cavity with inclined ribs

Numerical Investigation of Convective Heat Transfer in Pin Fin Type Heat Sink used for Led Application by using CFD

Estimation of Heat Dissipation from Plate with Multiple Tapered and Rectangular Fins

Advances in Fluid Mechanics and Heat & Mass Transfer

Passive Enhancement of Fin Performance Using Fractal- Like Geometries

Experimental investigation of heat transfer augmentation in triangular duct with rectangular wing

AN EXPERIMENTAL STUDY OF MIXED CONVECTION HEAT TRANSFER IN AN INCLINED RECTANGULAR DUCT EXPOSED TO UNIFORM HEAT FLUX FROM UPPER SURFACE

Introduction to Heat and Mass Transfer. Week 5

Investigation of Jet Impingement on Flat Plate Using Triangular and Trapezoid Vortex Generators

Pin Fin Lab Report Example. Names. ME331 Lab

International Journal of Engineering, Business and Enterprise Applications (IJEBEA)

Department of Energy Science & Engineering, IIT Bombay, Mumbai, India. *Corresponding author: Tel: ,

Experimental Analysis for Natural Convection Heat Transfer through Vertical Cylinder

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB

Experimental Validation of Heat Transfer Enhancement in plate Heat Exchanger with Non Conventional Shapes of Rib

EXPERIMENTAL ANALYSIS OF THE INFLUENCE OF HEAT SINK GEOMETRIC PARAMETERS ON NATURAL CONVECTION

Chapter 9 NATURAL CONVECTION

Natural and Mixed Convection Heat Transfer Cooling of Discrete Heat Sources Placed Near the Bottom on a PCB

Neural Network Modeling of Parallel-Plain Fin Heat Sink

Analysis of the Cooling Design in Electrical Transformer

Chapter 3: Steady Heat Conduction. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

HEAT TRANSFER ENHANCEMENT BY USING NANOFLUID JET IMPINGEMENT

University of New Mexico Mechanical Engineering Fall 2012 PhD qualifying examination Heat Transfer

ENSC 388. Assignment #8

Experimental Comparison of Heat Transfer by Natural Convection from Plain Vertical Plate and Vertical Plate with Inline Dimples

IJRASET: All Rights are Reserved

Solar Flat Plate Thermal Collector

Effective Heat Transfer Enhancement in Finned Tube Heat Exchanger with Different Fin Profiles

Coolant. Circuits Chip

Akshay Andhare 1, Samer Khan 2 Research scholar, Assistant Director, Dept. of Applied Research, Mewar University, Gangrar NH 79, Chittorgarh (India)

Enhancement of Heat Transfer Effectiveness of Plate-pin fin heat sinks With Central hole and Staggered positioning of Pin fins

Computational Fluid Dynamics Based Analysis of Angled Rib Roughened Solar Air Heater Duct

CFD Analysis & Experimental Investigation to improve Heat Transfer Enhancement in flat plate with W Ribs

Experimental and Numerical Study of Free Convective Heat Transfer on the Triangular Fin for the Optimum Condition of Gap's Configuration

Heat Transfer Enhancement of Solar Air Heater By Using Artificial Roughness double inclined ribs

Experimental Analysis of Wire Sandwiched Micro Heat Pipes

Heat Augmentation Using Non-metallic Flow Divider Type Inserts in Forced Convection

International Communications in Heat and Mass Transfer

Design and Heat Transfer Enhancement of Heat Sink by Natural Convection

Study on Heat Transfer during Rectangular Slot Air Jet Impingement on Curved Surfaces

External Forced Convection :

Florida Institute of Technology College of Engineering Department of Chemical Engineering

EFFECT OF DIFFERENT PARAMETERS ON THE PERFORMANCE OF RIB ROUGHNESS SOLAR DUCT

Experimental Investigation of Heat Transfer from a Flat and Surface Indented Plate Impinged with Cold Air Jet- Using Circular Nozzle

Thermo-Hydraulic performance of Internal finned tube Automobile Radiator

Free and Forced Convection Heat Transfer Characteristics in an Opened Box with Parallel Heated Plates

THERMO-MECHANICAL ANALYSIS IN PERFORATED ANNULAR FIN USING ANSYS

PROBLEM 1.2 ( ) 25 C 15 C dx L 0.30 m Ambient air temperature, T2 (C)

W-Discrete Rib for Enhancing the Thermal Performance of Solar Air Heater

A Demonstration Unit to Enhance Heat Transfer Lectures on Natural and Forced Convection

ENHANCED HEAT TRANSFER CHARACTERISTICS OF CONJUGATED AIR JET IMPINGEMENT ON A FINNED HEAT SINK

Natural Convection from Horizontal Rectangular Fin Arrays within Perforated Chassis

Transcription:

International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2016 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Experimental Study of Parallel Plate Fin Heat Sinks with and without Perforation on Circular Pin Fins between the Plate Fins Rahul R. Sonawane * and D. D. Palande 1 Department of Mechanical Engineering, Savitribai Phule Pune University, MCOERC Nashik, India Accepted 15 June 2016, Available online 20 June 2016, Special Issue-5 (June 2016) Abstract It is very important to enhance the heat transfer rate and ensure the better cooling of electronic devices. The fined surface is most commonly used to dissipate heat quickly to the surrounding flowing fluid. Experiment is carried out to investigate heat transfer rate in natural convection of parallel plate fin heat sink with circular pin fins placed between the plate fins. The firstly parallel plate heat sink consists of without perforated circular pin fin and its performance is compared with perforated circular pin fin. The height of circular pin fin is taken as 50 mm, 35 mm, 25 mm respectively for both cases. Further the number of perforation on pin fin increases and its effect on heat transfer rate is also examined. The result shows that, parallel plate fin heat sink with perforated circular pin fins gives more heat transfer than without perforated circular pin fins. In above three cases, it is observed that circular pin fin at 25 mm height shows better heat transfer than other two heights. The increase in number of perforation on each pin fin increases heat transfer rate. Keywords: Parallel plate fin Heat sink, Circular pin fins, Perforation, Heat transfer rate. 1. Introduction 1 Electronic systems during their operation generate heat. This heat has to be dissipated quickly to surrounding atmosphere otherwise it may increase the temperature of the electronic components. It is very necessary to maintain the operating temperatures of electronics components at a safe and satisfactory level. Heat sink is used to dissipate the heat rapidly to surrounding fluid. (Dong-Kwon Kim, et al, 2009) compared plate and pin-fin heat sinks subjected to an impinging flow for different flow rates and channel widths. They found that optimized pin-fin heat sinks shows lower thermal resistances when dimensionless pumping power is small and the dimensionless length of heat sinks is large. (Abdullah H, et al, 2009) compared solid and perforated horizontal rectangular fin in natural convection by using finite element technique. They observed that, perforated horizontal rectangular fin has more heat transfer and less weight compared to equivalent solid fins. (E.A.M.Elshafei, 2010) compared solid circular pin fins with perforated circular pin fins in staggered arrangement in natural convection. They also tested performance of heat sink for two different orientations and observed that, the perforated pin fins gives better heat transfer in sideward arrangement than upward arrangement. (Monoj Baruah, et al, 2011) *Corresponding author: Rahul R. Sonawane investigated the performance of elliptical pin fins which arranged in a staggered manner. Three perforations were provided on elliptical pin fins and its performance compared with corresponding solid elliptical pin fin. They have observed that, the three perforations on elliptical pin fins gives more heat transfer. (Anupam Dewan, et al, 2011) also studied heat transfer from an array of circular pin fins and observed that, the perforation on pin fin reduces the weight and the cost of pin fin. (Ji-Jinn Foo, et al, 2012) studied heat transfer with perforated pin fin by varying the number of horizontal perforation and the diameters horizontal and vertical perforation on pin fin. They found that, the perforated pin fin array gives more heat transfer than the corresponding solid pins. (G. Ganesh Kumar, 2013) observed that the variation of local temperature difference is more for hollow perforated pin fin compared to that the solid perforated pin fin. (Ali Shakir Baqir, et al, 2014) studied staggered perforated pin fin array in a rectangular channel. They have compared HLV (horizontal, vertical, lateral) perforated pin fin with HV perforated and solid pin fin. They observed that the HLV perforated pin fin shows higher heat transfer than HV perforated and solid pin fin heat sink. (Saurabh D. Bahadure, and G. D. Gosavi, 2014) carried out the thermal performance of a pin fin heat sink. In experiment, they varied the material of pin fin such as Aluminum, Copper and mild steel and number 375 MIT College of Engineering, Pune, India, MECHPGCON 2016, INPRESSCO IJCET Special Issue-5 (June 2016)

of perforation on pin fin from 1 to 3 respectively. They found that the average heat transfer coefficient is higher for three perforations compared to solid, single, and two perforations respectively. (Murtadha Ahmed and Abdul Jabbar N. Khalifa, 2014) compared solid and perforated square pin fin heat sinks in natural convection. They found that the temperature drop across perforated pin fin was less than that of solid pin fins. (Vishvas S. Choure, 2015) studied heat transfer enhancement from perforated pin fin in staggered arrangement. The number of Perforation varied from one to five and diameter of perforation from 3 to 5 respectively. They have observed that the Nusselt number increases with increase in number of perforation and diameter of In present study, experiment is carried out to investigate heat transfer rate in natural convection of parallel plate fin heat sink with circular pin fins placed between the plate fins. The firstly parallel plate heat sink consists of without perforated circular pin fin and its performance is compared with perforated circular pin fin. The variation of height of circular pin fin and effect of number perforation on heat transfer coefficient is also examined. 2. Experimental Setup 2.1 Heat Sinks Dimensions The dimensions of the setup are given as below; Base plate = 133 mm x 155 mm. Height of parallel plate fin = 50 mm. Thickness of parallel plate fin = 3 mm. Height of pin fin = 50 mm, 35 mm, 25 mm respectively. Diameter of circular pin fin = 8 mm. Diameter of perforation = 3 mm. No. of perforation =1, 2. 2.2 Experimental setup and procedure The experimental set-up primarily consists of wooden rectangular chamber and digital control panel as shown in Fig.1. The rectangular wooden chamber is made in such way that it is open from top and bottom portion while all other sides are closed. The three sides of chamber are closed with plywood and front side of chamber has removable glass sheet so as to replace different types of pins. Inside the chamber the concrete block supported with the help of wooden block. The heater plate is placed on the concrete block to supply heat input to heat sink model. The test set up was kept in controlled room to establish free convection over pin fin arrays. The parallel plate pin fin heat sink is mounted on concrete block with the help of four screws to tight pin fin array over heater plate. Thermocouples are sandwiched between heater plate and heat sink at different locations to measure the temperature of base of fin. Thus, air gap between heater plate and pin fin array is consider to be negligible. Also, heat loss through excess portion to the pin fin arrays was assumed negligible for comparative analysis. Fig.1 Experimental Set-up The plate fin configurations are produced by milling operation on rectangular block. The plate fin arrays were produced from rectangular block with dimensions 138 188 63 mm. Fins were kept integral with the base plate of thickness 10 mm while, fin thickness was kept constant as 3 mm. The circular pin has 8 mm diameter and they are placed between the parallel plate fins. Geometry of pin fin array is shown in the Fig.3. The fin material was selected as aluminum 6063 alloy because of its high thermal conductivity, k ~ 202 W/m.K at 20, low emissivity (~ 0.2 at 20 ). For the experimentation, electrical power supplied to heater and heat input is adjusted with the help of dimmer stat. The dimmer stat can be used to change the heat input such as 20W, 40 W, 60 W, 80 W and 100W. As heater goes on heating, the temperature of fin start rising which is sensed by the thermocouple and indicated on digital temperature indicator. The base-plate temperatures of fin arrays are measured by T1, T2, T3, T4 and T5 thermocouples and ambient temperature by T6 thermocouples. The average of these five readings is taken as the base plate temperature. The heater input is kept constant for different set of heat sink model and noted the reading. Fig.2(a) Height of pin 50 mm without perforation 376 MIT College of Engineering, Pune, India, MECHPGCON 2016, INPRESSCO IJCET Special Issue-5 (June 2016)

Fig.2(b) Height of pin 50 mm with single perforation Fig.2(g) Height of pin 25 mm without perforation Fig.2(c) Height of pin 50 mm with double perforation Fig.2(h) Height of pin 25 mm with single perforation Fig.2(d) Height of pin 35 mm without perforation Fig.2(i) Height of pin 25 mm with double perforation Fig.2 Nine parallel plate pin fin models. Fig.2(e) Height of pin 35 mm with single perforation Parallel plate pin fins heat sinks are the heart of experiment over which the experimental study is be done. In the experimentation for all three height solid set of pin fin are compared with single and double perforated pin fin. There are nine pin fin geometries are as shown in Fig.2. Fig.2(f) Height of pin 35 mm with double perforation 3. Data Reduction Heat input supplied to fins is given by, Q in = VI (1) The most of the heat lost by radiation to surrounding air which is calculated as, Q rad = ɛσ A s (Ts 4 Ta 4 ) (2) Heat lost by convection Q C = Q in- Q rad This rate of heat transfer by convection can be given by, 377 MIT College of Engineering, Pune, India, MECHPGCON 2016, INPRESSCO IJCET Special Issue-5 (June 2016)

Q C = h A s (Ts Ta) (3) 3.1 Calculation of base and exposed area of fins Area of base plate (A bp) =L x W Area of one plate fin= (2xHxL) + (2xHx t)+ (L x t) Area of all vertical plate fin (A f)= Area of one plate fin x No. of fin Area of all vertical pin fins with perforation is, (A pf)= Nf + (πdh) (n + nπdd)} Total surface area A s=a bp+ A f + A pf (4) The mean temperature is calculated as, (5) The average convective heat transfer coefficient is given by, (6) Fig.4 Variation of temperature difference vs Heat input for 50 mm pin fin height. 4. Results and Discussion In the experiment for three different heights, solid pin fins are compared with single and double perforated pin fin. For all nine set heat is kept constant as 20W, 40 W, 60 W, 80 W and 100W. Fig.5 Variation of heat transfer coefficient vs Heat input for 35 mm pin fin height. The Fig.5 shows variation of heat transfer coefficient vs heat input for 35 mm pin fin height. It is observed that, double perforated pin fin has heat transfer coefficient 5.23 W/m 2 k at 100W whereas perforated and solid pin fin has 4.92 W/m 2 k, 4.72 W/m 2 k respectively. Fig.3 Variation of heat transfer coefficient vs Heat input for 50 mm pin fin height. The Fig.3 shows variation of heat transfer coefficient vs heat input for 50 mm pin fin height. It is observed that, double perforated pin fin has heat transfer coefficient 4.69 W/m 2 k at 100W whereas single perforated and solid pin fin has 4.44 W/m 2 k, 4.33 W/m 2 k respectively. The double perforated pin fin has higher heat transfer coefficient compared single perforated and solid pin fin. The Fig.4 shows Variation of temperature difference vs heat input for 50 mm pin fin height. At 100W, the temperature difference value for solid pin fin is 88.2 C whereas for single and double perforated pin fin is 87.8 C, 85.8 C respectively. The lesser is the value of ΔT higher is the heat transfer coefficient. Fig.6 Variation of temperature difference vs Heat input for 35 mm pin fin height. The Fig.6 shows Variation of temperature difference vs heat input for 35 mm pin fin height. At 100W, the temperature difference value for solid pin fin is 87.6 C whereas for single and double perforated pin fin is 378 MIT College of Engineering, Pune, India, MECHPGCON 2016, INPRESSCO IJCET Special Issue-5 (June 2016)

86.4 C, 84 C respectively. The lesser is the value of ΔT higher is the heat transfer coefficient. Fig.7 Variation of heat transfer coefficient vs Heat input for 25 mm pin fin height. Fig.9 Variation of heat transfer coefficient vs Heat input for different pin fin height without The Fig.7 shows that heat heat transfer coefficient increases with increase heat input. At 25 mm pin height double perforated pin fin has higher heat transfer coefficient as 5.75 W/m 2 k compared to solid and single perforated pin fin. Fig.10 Variation of heat transfer coefficient vs Heat input for different pin fin height with single Fig.8 Variation of temperature difference vs Heat input for 25 mm pin fin height. The Fig.8 shows that temperature difference value is more in solid pin compared to single and double perforated pin fin respectively. Higher is the value of temperature difference lesser is the heat transfer coefficient. At 100W solid pin fin has temperature difference value 85.8 C whereas single and double perforated pin fin has 84.4 C, 81.6 C respectively. The less value of ΔT is observed for smaller pin fin height i.e. at 25mm. The value of ΔT along the height of pin goes on rising and decreases the heat transfer performance. From the fig.9 it is observed that, 25 mm pin fin height gives higher heat transfer coefficient compared to 35 mm and 50 mm pin fin height. From the Fig.10 it is observed that, 25 mm pin fin height with single perforation gives higher heat transfer coefficient compared to 35 mm and 50 mm pin fin height. Fig.11 Variation of heat transfer coefficient vs Heat input for different pin fin height with double From the Fig.11 it is observed that, 25 mm pin fin height with double perforation gives higher heat transfer coefficient compared to 35 mm and 50 mm pin fin height. Conclusions 1) From experimental study, it is concluded that for all three pin fin height the parallel plate heat sink with perforated circular pin fin gives more heat transfer rate than solid circular pin fin. 379 MIT College of Engineering, Pune, India, MECHPGCON 2016, INPRESSCO IJCET Special Issue-5 (June 2016)

2) Average heat transfer coefficient for double perforations is higher than solid, single perforation respectively. The heat transfer rate increases with increase in number of 3) Out of three different pin heights, it is observed that the heat transfer coefficient is maximum for 25 mm and minimum for 50 mm pin height. 4) As lesser is the value of temperature difference higher is the heat transfer coefficient. The temperature difference is less for 25 mm pin fin height compared to 35 mm and 50 mm respectively. 5) The temperature difference for double perforated pin fin is very less than solid and single perforated pin fin. Nomenclature L= Length of fin (m) W= Width of fin (m) T= Thickness of fin (mm) Nf= Total number of pin fin D= Diameter of circular pin(mm) H=Height of fin (mm) d=perforation diameter (mm) n= Number of perforation Nu=Nussult number Kair= Thermal conductivity of air (W/mk) Lc= Characteristic length.(mm) h= Heat transfer coefficient.(w/m 2 k) Q in= Heat input to the plate pin fin-array assembly (W) Q rad = Heat lost by radiation(w) Q C = Heat transfer by convection (W) ɛ= Emissivity A bp = Area of base plate (m 2 ) A f = Area of plate fin (m 2 ) A pf = Area of pin fin (m 2 ) A s = Total surface area of plate pin fin. (m 2 ) σ = Stefan Boltzman constant (W/m 2 k 4 ) Ts=Average surface temperature of base plate ( C) Ta= Ambient temperature ( C) Tm= Mean temperature ( C) ΔT= Temperature difference ( C) References Dong-Kwon Kim, Sung Jin Kim, Jin-Kwon Bae, (2009), Comparison of thermal performances of plate-fin and pinfin heat sinks subject to an impinging flow, International Journal of Heat and Mass Transfer 52, pp. 3510 3517. Abdullah H. AlEssa, Ayman M. Maqableh and Shatha Ammourah, (2009), Enhancement of natural convection heat transfer from a fin by rectangular perforations with aspect ratio of two, International Journal of Physical Sciences, volume 4 (10), pp. 540-547. E.A.M. Elshafei, (2010), Natural convection heat transfer from a heat sink with hollow/perforated circular pin fins, Energy 35, pp. 2870-2877. Monoj Baruah, Anupam Dewan and P. Mahanta, (2011), performance of elliptical pin fin heat exchanger with three elliptical perforations, ISSR Journals, Volume 3 (2), pp. 65-70. Anupam Dewan, Rajesh Kumar Shukla, (2011), computation of turbulent convective heat transfer in a hollow cirular pin fin heat exchanger, Proceedings of the 21 st National and 10 th ISHMT-ASME Heat and Mass Transfer Conference, IIT Madras, India. Ji-Jinn Foo, Shung-Yuh Pui, Yin-Ling Lai, Swee-Boon Chin, (2012), Forced convective heat transfer enhancement with perforated pin fins subject to an impinging flow, SEGi Review, volume 5, number 1, pp. 29-40. G.Ganesh Kumar, (2013), Comparative studies on conjugate mixed convection in perforated fins, International Journal of Science and Research, pp. 2319-7064. Ali Shakir Baqir, Ahmed Qasim, Anmar Adnan, (2014), Experimental study for staggered perforated array of pins like fins in a rectangular air cross flow, The Iraqi Journal For Mechanical And Material Engineering, volume 14, number 2, pp. 261-275. Saurabh D.Bahadur. and G.D. Gosavi, (2014), Enhancement of natural convection heat transfer from perforated fin, International Journal of Engineering Research,volume 3, issue 9, pp. 531-535. Murtadha Ahmed and Abdul Jabbar N. Khalifa, (2014), Natural convection heat transfer from a heat sink with fins of different configuration International Journal of Innovation and Applied Studies, volume 9, number 3, pp. 1043-1047. Vishvas S. Choure, Mahesh R. Jagadale, Vijay W. Bhatkar, (2015), Heat transfer enhancement using perforated pin Fins, International Journal For Technological Research In Engineering,volume 3, issue 2, pp. 2347 4718. 380 MIT College of Engineering, Pune, India, MECHPGCON 2016, INPRESSCO IJCET Special Issue-5 (June 2016)