Flow control unit FCU-400

Similar documents
Operating Instructions for Digital Manometer. Model: MAN-SD

WeatherHub2 Quick Start Guide

Lamp and Control Panel (Lamp Panel)

Installation guide 862 MIT / MIR

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

ISSP User Guide CY3207ISSP. Revision C

Operating instructions Magnetic-inductive flow meter SM6x04 SM7x04 SM8x04

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

Minute Impulse Clock Controller I01DN

Operating instructions Pressure sensor PN / / 2007

Operating instructions Vortex flow meter. SVxxx / / 2015

User Manual VX4750 Function Generator Module

O P E R A T I N G M A N U A L

Microcare LCD Solar MPPT User Documentation

VELA. Getting started with the VELA Versatile Laboratory Aid. Paul Vernon

WE RE HERE TO HELP: 1 (844) LIGHTCLOUD

Operating instructions Magnetic-inductive flow meter. SM6x01 SM7x01 SM8x / / 2015

MAGPOWR TENSION CONTROL DLCA NET-SLIM. User Manual. Digital Load Cell Amplifier MI 850A358 1 A

Zetasizer Nano-ZS User Instructions

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

ISEmax CAM40/CAS40. Technical Information

Bright Advance Corporation

INSTRUCTION MANUAL FOR MM10 Relay

OPERATING MANUAL. EIB-Kombisensor AS 315 N

Quick Start Guide New Mountain Visit our Website to Register Your Copy (weatherview32.com)

PiCUS Calliper Version 3

Orbit Support Pack for Excel. user manual

Instruction Manual SEFRAM Thermal Camera

PHOENIX CONTACT - 04/2016. Features

PAA-ANALYZERS PRINCIPLE OF OPERATION

Instruction. Vacuum Circuit Breaker Operator Module. Type 3AH 4.16kV to 38kV. Power Transmission & Distribution

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

Circular Motion and Centripetal Force

Paramaters. Resolution 0.2 m (for measurements < 25 meas. / sec )

Doc No. KF08-002D. Portable Ultrasonic Flowmeter UFP-20. Installation & Operation Manual

Assembly and Operation Manual. April 2016

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

QUANTUM CONCEPT. Swimming User s Manual

HD2016. [ GB ] Weighing rain gauge. Rain PART OF G H M GROUP TELEMETRIE & AUTOMATION TELEMETRIE & AUTOMATION

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Acceleration/Velocity/Displacement VIBRATION METER

Operation Manual. SPECTRO-NANO4 Nucleic Acid Analyzer PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Ultra-Small Footprint N-Channel FemtoFET MOSFET Test EVM

AKD SYSTEM CONFIGURATION WITH KOLLMORGEN DDL LINEAR MOTORS By Kenny Hampton 1/12/2017 Rev. L

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Heat Meter WR 200-D. 2 temperature inputs for Pt100 in four-wire circuit. Exact calculation of the heat parameters according IAPWS-IF97

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

ph electrode Instruction Manual For use with the RAH-210 & RPH-250

VIBRATION METER. Instruction Manual.

XR Analog Clock - Manual Setting Model Troubleshooting Guide

Motors Automation Energy Transmission & Distribution Coatings. Servo Drive SCA06 V1.5X. Addendum to the Programming Manual SCA06 V1.

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

TECDIS and TELchart ECS Weather Overlay Guide

WLDS-20 Mk2 MAJOR WATER LEAK DETECTION SYSTEM INSTALLATION & COMMISSIONING

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

Quick Reference. Daily Cleaning Procedures Pages 3-8 Stopping Conditions & Recovery Steps Pages 9-20

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Drive electronics pq12

Operating instructions Compressed air meter SD / / 2013

Lightcloud Application

Operating instructions Compressed air meter SD / / 2013

473-SHX Dew Point Mirror

DEIF A/S. MTR-2-015, -315, -415, MTR-2F-215 Multi-configurable AC transducer C. Modbus Communication Manual.

Semi-automatic titrators PH-Burette. A great ph-meter with integrated burette. Incredible price! Infinite possibilities

KZPb

Magnetic Fields. Experiment 1. Magnetic Field of a Straight Current-Carrying Conductor

SPECIFICATION SHEET : FHS2-UNV-36L

S Sapling INSTALLATION MANUAL FOR FIELD SELECTABLE ANALOG CLOCKS SAA SERIES SPECIFICATIONS. advanced time and control systems

Account Setup. STEP 1: Create Enhanced View Account

INSTRUCTION AND MAINTENANCE MANUAL FOR TECHTROL COUNTER CONTROLLER & TOTALISER (TCCT)

In-System Serial Programming (ISSP) Guide

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Field Pro Operation and Installation Manual

ER2 Short-head Electric Chain Hoist

Periodic Inspection and Testing of Electrical Installations Sample Test ( ) Version 1.3 July 2018

Structure Monitoring Technology. Features. Ordering Information. Trigger Tape. A2 Pulse Counter (Optional) Solar Radiation Sensor

Oberebenestrasse Bremgarten Switzerland Tel Fax

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

WS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual

Non-Acoustical Inputs

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

DIGITAL ABBE REFRACTOMETER INE-WYA-2S OPERATING INSTRUCTION PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Software BioScout-Calibrator June 2013

Elios X3 DIGITAL CONTROL SYSTEM FOR THE MANAGEMENT OF SOLAR HEAT PLANT

In-System Serial Programming (ISSP) Guide

E6C-N. Ideal for Out-of-step Detection of Stepping Motors and Position Control of Rotors and Unloaders

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

Analogue Meters CQ2x07 series

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

NINE CHOICE SERIAL REACTION TIME TASK

KZMb

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

A clock designed in close consultation with people living with Dementia.

Dielectric Analysis of Solid Insulations

Transcription:

průmyslová elektronika INSTRUCTION MANUAL Flow control unit FCU-400 applicable to firmware version 2.0 Read carefully the instructions published in this manual before the first use of the level meter. Keep the manual at a safe place. The manufacturer reserves the right to implement changes without prior notice.

Table of Contents 1. Measurement principle and application area...4 2. Dimension drawings...4 3. Put in service procedure...5 4. Level meter installation...6 5. Face panel and terminal block...6 6. Example of FCU-400 unit connection with ULM-53-M level meters......6 7. Electric connection...7 8. Level meter setup...8 8.1. Device keyboard...8 8.2. Switching measurement ranges and menu navigation...8 8.3. Lock / unlock...10 8.4. Evaluation unit configuration...11 8.5. Reading statistical data...20 8.6. Other information...22 9. Marking method...23 10. Examples of correct marking...23 11. Protection, safety, and compatibility...23 12. Usage, operation, and maintenance...23 13. Marking of labels...23 14. Specifications...24 Used symbols In order to provide maximum safety of processes, we have defined the following safety and information instructions. Each of the instructions is marked with an icon. Alert, warning, danger This symbol informs about particularly important instructions for installation and operation of equipment or about dangerous situations, which might occur during installation and operation. Failure to comply with the instructions may cause failures, damage, or destruction of the equipment, or may cause injuries of persons. Information This symbol informs about particularly important characteristics of equipment. Note This symbol identifies useful additional information.

Safety Any operations described in t his user's guide may only be performed by trained worker, or by assigned person. Warranty and post-warranty repairs shall be performed exclusively at the manufacturer. Incorrect usage, installation, or setup of the flow meter may result in accidents in application. Manufacturer is not responsible for any incorrect usage, work losses resulting from direct or indirect damage, and expenses rising from the installation or usage of the flow meter. Do not disassemble, repair, or modify the unit. The unit has no serviceable parts. In case you detect a failure, disconnect the unit from power supply voltage, and contact authorized service centre. Do not use the unit in explosive environment. Avoid unauthorized persons to contact with power supply terminals. 1. Measurement principle and application area Flow control unit FCU-400 is used to measure and display volume flow rate in open channels and drains. The unit forms an assembly with ULM-53 ultrasonic level meter with RS485/Modbus RTU communication output where the power supply for sensors is provided directly from the unit with output voltage of 24V DC. The unit can measure immediate flow rates in up to 4 channels simultaneously. The unit is integrated in an instrument box intended for wall mounting. Connection terminal block is positioned inside of the bottom part of the unit. On the front panel, there are four buttons used to set all functions. The units can be equipped with either two or four relay outputs. They also include RS485/Modbus RTU - Master communication interface for connection of sensors and RS 485/Modbus RTU - Slave interface for the communication with the master. On the front panel, there is a USB input for transmission of archived data from the unit to a flash disc in csv format. Customer can also select a web server, or 0/4-20 ma current output. Binary input is included in the basic configuration. Particular types can be ordered in two power supply versions. 2. Dimension drawings FCU-400 CARDMASTER 166x160x80-106 188 166 M16/PG9 3xM20 2 7 27 28 2 9. 5 160 145 70 8 Ø5 28.8 17/16-L3 76.5 11 106 57.5 25.5 13.8 106 100 13.5 Ø10 56.3 85 2 160 17.5 2 115 31.8 8 112 Ø2.4 84.5 65.5 5.4 8 47 47.5 5 9.6 24.5 24 123 137.5 151 35 46 69 4

3. Installation and putting into operation This procedure includes the following three steps. Installation Electric connection Setting 4. Installation Any assembly and installation work shall be done with disconnected power supply. Both the measuring level meter and the control unit are designed for outdoors installation, and do not require any special construction and structure modifications of measuring profiles. The probed is designed for installation above flow profile. The values of flow rate and flown volume accuracy provided in specifications include an error due to the level measurement and conversion to the flow rate based on a consumption curve, however, they do not include error of specific flow rate profile. The measurement quality may be influenced by very high layer of foam on the water level. In case of measuring flumes, such a size must be selected to use its range well - it is inadmissible when the real flow rate value is only within the lower half of measuring range of the flume. In case of Thomson's overfall, units with small vertex angle should preferably be used so that the measured level is as high as possible. On case of flow at the upper limit of the working interval of the given measuring point, the level must be at least 30 cm, otherwise, the measurement accuracy is significantly lower. The control unit requires power supply of 230 V AC / 10 VA, or 24 V DC / 8 VA, the ultrasound probe is powered from the control unit. After the lower cover is unscrewed, L1, N, PE power supply terminal block is accessible. At this place, the equipment can only be operated by skilled person with higher qualification (see decree no. 50/1978 Coll. on expert qualification in electrical engineering). The measuring set accuracy depends on correct alignment of the probe, and setup of the unit operating parameters. The unit is hash-proof and complies with safety standards. The installation should be done in compliance with local regulations. Before installation, learn about basic safety requirements provided on page 4. Make sure the power supply voltage in the grid complies with the nominal voltage indicated on the identification label of the unit. Load shall comply with requirements provided in specifications. Final assembly, commissioning, and programming of internal (non-user) parameters are done by a service group, or properly trained persons, if applicable! Before installation, disconnect the power supply source. Before the first startup, check the cables for correct correction to the unit. The measuring set accuracy depends on correct alignment of the probe, and setup of the unit operating parameters. 5

5. Face panel and terminal block terminal no. all types of FCU-400 1 L / + (230 / 24 V) 2 N / - (230 / 24 V) 3 PE 4 RE 1 (100 ma / 250 V AC ) 5 RE 1 (100 ma / 250 V AC ) 6 RE 2 (100 ma / 250 V AC ) 7 RE 2 (100 ma / 250 V AC ) 8 RE 3 (24 V DC ) 9 RE 3 (24 V DC ) 10 RE 4 (24 V DC ) 11 RE 4 (24 V DC ) 12 Cable shielding (RS 485 - Master) 13 A (RS 485 - Master) 14 B (RS 485 - Master) 15 Cable shielding (RS 485 - Slave) 16 A (RS 485 - Slave) 17 B (RS 485 - Slave) 18 + US 19 - US 20 Bi (binary input for zero reset) 21 Bi (binary input for zero reset) terminal no. types FCU-400-R_-0(W) type FCU-400-R_-I 22 RJ45/Ethernet active current output (+ 24 V) 23 - active current output (0 V) 24 - passive current output ( + ) 25 - passive current output ( - ) Front panel Flow Control Unit FCU-400 www.dinel.cz Poznámka: šedé orámování tlačítek bude ještě v rovině fólie Terminal block FCU-400-R_-0(W) RE1 L/+ N/- PE RE2 1 2 3 6 7 RE3 4 5 8 9 RE4 S 10 11 15 RS 485 - Master A 12 13 14 S A B 16 17 +24V DC Imax=120 ma _ + 18 19 B Bi Bi 20 21 RJ45 22 RS 485 - Slave Terminal block FCU-400-R_-I RE1 L/+ N/- PE RE2 1 2 3 6 7 RE3 4 5 8 9 RE4 10 11 15 RS 485 - Master S A 12 13 14 S A B 16 17 RS 485 - Slave +24V DC Imax=120 ma _ + 18 19 B Bi Bi 20 21 + Iout active _ 22 23 + _ 24 25 passive 6

4x ULM 53 (RS 485/ Modbus RTU output) legend: BN brown WH white YE yellow GN green Cab.Sh. cable shielding 6. Example of FCU-400 unit connection with ULM-53-M level RS 485 - Master S A B + +24V DC Imax=120 ma 12 13 14 18 19 _ Cab.Sh. (A) YE (B) GN (+U) BN (0V) WH Cab.Sh. (A) YE (B) GN (+U) BN (0V) WH Cab.Sh. (A) YE (B) GN (+U) BN (0V) WH Cab.Sh. (A) YE (B) GN (+U) BN (0V) WH 7

7. Electric connection Electric connections shall be made without voltage. A terminal block is accessible after unscrewing the lower cover on the front part of the unit. The power supply voltage (terminals 1 and 2) can be connected to the grid only using a fuse or breaker (max. 16A)! Terminals 12, 13, and 14 (RS 485 - Master) are only used for the connection of approved level meters with Modbus (ULM-53-M) output, see chapter 6. These level meters are powered from terminals 18 and 19, see chapter 6. The output of the equipment are working contacts (4, 5, and 6, 7, and 8,9, and 10,11). Terminals 15, 16, and 17 (RS 485 - Slave) are used as an interface for the Modbus communication with higher layer. 8. Setting of the evaluation unit Flow control unit FCU-400 can be operated using 4 buttons and OLED matrix display with resolution of 128x64 pixels. The buttons have various functions depending on their current position in menu. Actual functions of buttons are displayed in the lower part of the display above particular buttons. After the unit setup completion, it is recommended to RESET (CONFIGURATION / RESET), and verify correctness of preset parameters!) 8.1. Device keyboard C H A N N E L 1 5 P A R A M S E N S O R M E A S U R E M E N T E R R O R E C H O D A M P I N G 1 Button functions 0.57 Buttons 8.2. Switching of measuring channels and menu navigation Actual measured flow rate is displayed on the main screen. The main screen type can be set in DISPLAY MODE menu. (see chapter 7.4.7. a)). On the FLOW+TOTALIZER main screen, actual flow rate is shown with physical unit, its graphical representation, state of totalizer, state of output relays, and state of communication with sensor. The main screen is displayed just after the power supply is connected, and its graphical appearance is as follows: Identification of displayed measuring channel C H A N N E L 1 F L O W R E : 3 0.57m /s T O T 1735 3 O K "OK" communication is OK, sensor is receiving echo "NO RESPONSE" sensor does not respond to questions "COMM ERROR" sensor responds to questions with communication errors "NO ECHO" communication is OK, sensor is not receiving echo "OUT OF RANGE" measured value is out of the set range (limits of MIN. VALUE and MAX. VALUE) m State of output relay. From the left RE1-RE4. Empty field indicates inactive relay, full field indicates active relay. Bar graph showing the state of instantaneous flow rate with regard to set limits of MIN. VALUE and MAX. VALUE (see chapter 7.4.2. b)) Actual flow rate in the set unit State of totalizer 8

On the FLOW type screen, only the actual flow rate is shown. Graphical appearance of this screen is as follows: C H A N N E L 1 R E : O K 0.573 m /s By pressing the button 0.21 repeatedly, measuring channels with enabled visualisation can be switched (see chapter 1.2.2h). By pressing the button, you will return to the basic menu of the equipment. By pressing the button you will return to the main screen. C H A N N E L 1 R E : m /s O K 0.213 C H A N N E L 2 R E : l/s O K 233 C H A N N E L 3 N O R E S P O N S E R E : 3 m /s C H A N N E L 4 N O R E S P O N S E R E : 3 m /s 233 M A I N M E N U 0 S T A T I S T I C C O N F I G U R A T I O N D A T E / T I M E V I E W P A S S W O R D C H E C K D I A G N O S T I C You can navigate in menu using buttons and. By pressing the button, you enter to a submenu, and by pressing the button you will return to the previous menu. In menu in the upper part of the screen, name of superior item is displayed, including the menu identification number. Each menu has its unique identification number. Name of superior item C O N F I G U R A T I O N 2 I / O C H A N N E L S D I S P L A Y M O D E P A S S W O R D D A T E / T I M E F A C T O R Y D E F A U L T Menu identification number 9

8.3. Locking / unlocking configuration menu of the evaluation unit Complete configuration of the evaluation unit can be made in the CONFIGURATION menu within the main menu (MAIN MENU). Access to this menu is only allowed to authorized persons, and therefore, this menu is protected by a 4-digit user password. In production, this password is set to a default "1234". 8.3.1. Unlocking configuration menu of the evaluation unit The configuration menu can be unlocked using a valid access password. The password can be entered right at the time of entering to the CONFIGURATION menu from the main menu, or in the PASSWORD CHECK item in the main menu. For the purpose of entering the password, "INSERT PASSWORD?" text is displayed on the display. M A I N M E N U 0 S T A T I S T I C C O N F I G U R A T I O N D A T E / T I M E V I E W P A S S W O R D C H E C K D I A G N O S T I C I N S E R T P A S S W O R D? M A I N M E N U 0 S T A T I S T I C C O N F I G U R A T I O N D A T E / T I M E V I E W P A S S W O R D C H E C K D I A G N O S T I C I N S E R T P A S S W O R D? By pressing the button you return to the previous menu, and by pressing the button, the access password screen is displayed. The default password is "0000". By pressing the button, positions can be browsed. Current position is highlighted. By pressing the button, numbers to the current position can be entered in the range of 0 to 9. By pressing the button, the password is confirmed. P A S S W O R D 0 0 0 0 When the password is entered incorrectly, "INCORRECT" text is displayed, and by pressing the button the text "INSERT PASSWORD" is displayed again to enter the password or return to the previous menu. P A S S W O R D I N C O R R E C T E N T When the entered password is correct, by pressing the button the configuration is unlocked. When the password was entered at the time of entering to the CONFIGURATION menu, this menu will be accessed. When the password was entered in the PASSWORD CHECK item, you will return to the main menu. Then, for the access to the CONFIGURE menu, you will not need to enter the password. If the device is inactive for 10 minutes, it will automatically return to the main screen lock the unit. 10

8.3.2. Locking configuration menu of the evaluation unit The configuration menu can be locked in PASSWORD CHECK item in the main menu. For the purpose of entering the user password, "INSERT PASSWORD?" text is displayed on the display. By pressing the button you will return to the previous menu, and by pressing the button, a field to enter the password will show. To lock the configuration menu, leave the value of "0000" and confirm using the button. "INCORRECT" text shows on the display, and access to the unit's configuration menu is locked. P A S S W O R D 0 0 0 0 P A S S W O R D I N C O R R E C T E N T By pressing the button you will return to the main menu. 8.4. Configuration of the evaluation unit In the CONFIGURATION menu, you can completely configure particular measuring channels, change user's password, set internal date and time, and restore the device to the factory default. M A I N M E N U 0 S T A T I S T I C C O N F I G U R A T I O N D A T E / T I M E V I E W P A S S W O R D C H E C K D I A G N O S T I C 8.4.1. Pairing measuring sensors with the evaluation unit The following description is applicable to sensor configuration in the measuring channel 1. Configuration of other channels is identical. When connecting multiple sensors, they must be connected one by one. At first, connect the first sensor and configure it. Then, connect another sensor and configure it, etc. When connecting all the sensors at once, there is a risk for the sensors to have identical default address, resulting in communication collisions. In the CONFIGURATION/IO CHANNELS/INPUT CHANNELS/CHANNEL 1 menu, select ADDRESS, and set the measuring channel address identical with the sensor address (in the factory default setting, the ULM-53 sensor has address 0x01). C H A N N E L 1 5 A C T I V A T I O N V I S U A L I S A T I O N P A R A M S E N S O R M E A S U R E M E N T 1 I N S E R T V A L U E ( H E X ) 0 0 0 1 In the same menu, you can activate the ACTIVATION item by pressing the button. If the item is active, there is a symbol shown next to it. Otherwise, only the symbol is shown next to it. By activation of this item, communication between the evaluation unit and sensor is established. Channels with no connected sensors shall remain inactive. 5 C H A N N E L 1 5 A C T I V A T I O N V I S U A L I S A T I O N P A R A M S E N S O R M E A S U R E M E N T 1 11

a) Automatic parametrization of sensor Automatic parametrization of the sensor is used to set basic sensor parameters for its correct operation with the evaluation unit. In the CONFIGURATION/IO CHANNELS/INPUT CHANNELS/CHANNEL 1/PARAM SENSOR menu, select the AUTOSET item. P A R A M E T R I S A T I O N 5 0 A U T O S E T S E N S O R D I S T A N C E M E A S U R E P E R S E C S E N S I T I V I T Y After activation of this item, the sensor is automatically set. The configuration in progress is indicated with the "WRIT- ING" text. After the configuration is successfully completed, "WRITE OK" is displayed. W R I T E O K E N T In case the communication was not successful, "WRITE ERROR" is displayed. W R I T E E R R O R E N T By pressing the button you will return to the previous menu. The communication error may by caused by wrong connection of the sensor, or by wrong setting of the sensor address. b) Sensor to flume bottom distance setup In the CONFIGURATION/IO CHANNELS/INPUT CHANNELS/CHANNEL 1/PARAM SENSOR menu, select SENSOR DISTANCE, and set the distance of the sensor from the measuring flume bottom. The distance is set in meters with four decimal digits. By pressing the button, positions can be browsed. Current position is highlighted. By pressing the button, numbers to the current position can be entered in the range of 0 to 9. By pressing the button, set distance to sensor is confirmed and saved. P A R A M E T R I S A T I O N 5 0 A U T O S E T S E N S O R D I S T A N C E M E A S U R E P E R S E C S E N S I T I V I T Y I N S E R T V A L U E : + 0 0 0 0 0 1. 6 2 1 1 m After the write operation is successfully completed, "WRITE OK" is displayed. By pressing the button you will return to the previous menu. W R I T E O K E N T 12

c) Setup of number of sensor measurements per second Then, in the CONFIGURATION/IO CHANNELS/INPUT CHANNELS/CHANNEL 1/PARAM SENSOR menu, select MEASURE PER SEC item, and set the number of sensor measurements per second (1-5). P A R A M E T R I S A T I O N 5 0 A U T O S E T S E N S O R D I S T A N C E M E A S U R E P E R S E C S E N S I T I V I T Y I N S E R T V A L U E : After the write operation is successfully completed, "WRITE OK" is displayed. In case any values out of range are entered (1-5 allowed), "WRITE ERROR" is displayed. By pressing the button you will return to the previous menu. d) Sensor internal address setup In the CONFIGURATION/IO CHANNELS/INPUT CHANNELS/CHANNEL 1/PARAM SENSOR menu, select ADDRESS, and set the new address of the sensor. Set the address in the range of 0x01 to 0xF7 (247 in decimal system). After the successful write operation completion, "WRITE OK" is displayed again. By pressing the button you will return to the previous menu. 2 P A R A M E T R I S A T I O N 5 0 A U T O S E T S E N S O R D I S T A N C E M E A S U R E P E R S E C S E N S I T I V I T Y I N S E R T V A L U E ( H E X ) 0 0 0 0 Since the internal address of the sensor is changed, the measuring channel address must be changed, too. In the CONFIGURATION/IO CHANNELS/INPUT CHANNELS/CHANNEL 1 menu, select ADDRESS, and set the address. C H A N N E L 1 5 A C T I V A T I O N V I S U A L I S A T I O N P A R A M S E N S O R M E A S U R E M E N T Thus, the sensor parametrization is finished. e) Sensor sensitivity setup 1 Then, in the CONFIGURATION/IO CHANNELS/INPUT CHANNELS/CHANNEL 1/PARAM SENSOR menu, select SENSITIVITY, and select HIGH or LOW sensitivity. P A R A M E T R I S A T I O N 5 0 A U T O S E T S E L E C T S E N S I T I V I T Y S E N S O R D I S T A N C E M E A S U R E P E R S E C L O W S E N S I T I V I T Y E EN N T f) Communication with sensor state check up Check the communication and measurement state in the DIAGNOSTIC item in the main menu. Select required channel using button, and check the sensor for its communication with the evaluation unit. The communication state is expressed by one of five messages in the left lower corner of the display: OK... communication is OK, sensor is receiving echo COMM ERROR...sensor responds to questions with communication errors NO RESPONSE... sensor does not respond to questions NO ECHO...communication is OK, sensor is not receiving echo OUT OF RANGE... measured value is out of the set range (limits of MIN. VALUE and MAX. VALUE) In case of multiple connected sensors, repeat the procedure in chapter 7.4.1. for each of the connected sensors (CHAN- NEL 1 to CHANNEL 4). 13

8.4.2. Flow rate measuring channel setup The following description is applicable to the evaluation unit configuration in the measuring channel 1. Configuration of other channels is identical. a) Flow rate unit of measure setup In the CONFIGURATION/IO CHANNELS/INPUT CHANNELS/CHANNEL 1/MEASUREMENT/ FLOW menu, select UNITS, and set the required flow rate unit of measure. F L O W 4 6 U N I T S R A N G E F L U M E S F O R M A T S U P P L E V E L S E L E C T U N I T 3 m /s Using and buttons, required unit of measure can be selected. When the E N T E N T button is pressed, the set unit of measure is saved, and you will return to the previous menu. b) Measured flow rate range setup In the same menu, select RANGE, and in the MIN.VALUE and MAX.VALUE menu, set the minimum and maximum value for the flow rate. The value is set in the physical unit of measure set in the previous item a). F L O W 4 6 U N I T S R A N G E F L U M E S F O R M A T S U P P L E V E L R A N G E 2 4 M I N. V A L U E M A X. V A L U E These values are used to graphically show the flow rate in the bar graph (see chapter 7.2) and to verify the limits of the measured flow rate. In case these limits are exceeded, the measurement is stopped and an error is indicated by "OUT OF RANGE" message (see chapter 7.2) c) Consumption curve setup In the CONFIGURATION/IO CHANNELS/INPUT CHANNELS/CHANNEL 1/MEASUREMENT/ FLOW menu, select FLUMES. F L O W 4 6 U N I T S R A N G E F L U M E S F O R M A T S U P P L E V E L The measured height of the level can be recalculated to the flow rate using a pre-defined P1 to P9 consumption curves for Parshall's flumes, or by user defined consumption curve based on a formula. In case of pre-defined Parshall's flumes, select PREDEF. PARSHALL. F L U M E S 6 8 P R E D E F. P A R S H A L L F O R M U L A L O A D F R O M U S B P A R S H A L L P 3 Using button, select required flume type, and using button, confirm, and return to the previous menu. 14

In case of user defined curve, select FORMULA. F L U M E S 6 8 P R E D E F. P A R S H A L L F O R M U L A L O A D F R O M U S B Then, using button, select required formula for the consumption curve the SELECT FORMULA menu, and by pressing the button, confirm and return to the previous menu. F O R M U L A 8 5 S E L E C T F O R M U L A I N S E R T C O N S T A N T S Q = A * H ^ D + E 3 Q... F L O W ( m / s ) H... L E V E L ( m ) A, D, E... C O N S T A N T E E N T In the INSERT CONSTANTS menu, define constants for the selected formula. F O R M U L A 8 5 S E L E C T F O R M U L A I N S E R T C O N S T A N T S C O N S T A N T S 9 0 A B C D In case of user defined curve using a table, select LOAD FROM USB. F L U M E S 6 8 P R E D E F. P A R S H A L L F O R M U L A L O A D F R O M U S B When the button is pressed, a table is loaded to the internal memory of the evaluation unit. Table definition: File name and format: data.csv Column delimiter: semicolon Left column: level height in meters Right column: flow rate in m 3 /s Format of values: decimal number, decimal part separated with point Maximum number of curve points (table rows): 128 15

d) Measured flow rate format setup (number of decimal points) In the CONFIGURATION/IO CHANNELS/INPUT CHANNELS/CHANNEL 1/MEASUREMENT/ FLOW menu, select FORMAT. F L O W 4 6 U N I T S R A N G E F L U M E S F O R M A T S U P P L E V E L S E L E C T F O R M A T X X X. X X Using buttons, select required number of decimal points. Using this format, the measured value will be displayed on the main screen (see chapter 7.2). In case the range is exceeded, "------" symbols are displayed. e) Small flow suppression setup Select SUPP LEVEL in the same menu. This item is used to suppress small flow rate values. Until the set level height is not reached, zero flow rate will be indicated. The level height is set in meters with four decimal digits. F L O W 4 6 U N I T S R A N G E F L U M E S F O R M A T S U P P L E V E L I N S E R T V A L U E : + 0 0 0 0 0 0. 0 1 0 0 m f) Echo loss maximum time setup In the CONFIGURATION/IO CHANNELS/INPUT CHANNELS/CHANNEL 1 menu, select ERROR ECHO and set the maximum time of the loss of echo (0-99 s). C H A N N E L 1 5 V I S U A L I S A T I O N P A R A M S E N S O R M E A S U R E M E N T E R R O R E C H O 1 I N S E R T V A L U E : 0 1 S E C In case the sensor fails to receive echo for a longer time than the set time, this loss is evaluated as a failure state. This state is indicated on the main screen. g) Measurement response time setup This function is useful for the suppression of variations during fast or step changes in the level height (turbid level). The consequent measurement response time will be longer, and the evaluation unit will respond to fast changes with defined delay in seconds. Select DAMPING in the same menu, and set required measurement response time (0.0 9.9 s). C H A N N E L 1 5 P A R A M S E N S O R M E A S U R E M E N T E R R O R E C H O D A M P I N G 1 I N S E R T V A L U E : 0 1 S E C When the button is pressed, the set unit of measure is saved, and you will return to the previous menu. 16

h) Enabling visualisation of the measuring channel on the main screen When the measuring channel visualisation is enabled, the channel can be displayed on the main screen (see chapter 1.1). The channel visualisation on the main screen can be enabled using 5 button next to the VISUALISATION. If the item is active, there is a symbol shown next to it. Otherwise, only the symbol is shown next to it. C H A N N E L 1 5 A C T I V A T I O N V I S U A L I S A T I O N P A R A M S E N S O R M E A S U R E M E N T 1 8.4.3. Relay output setup Relay outputs can be set in CONFIGURATION/IO CHANNELS/RELAYS menu. I O C H A N N E L S 1 I N P U T C H A N N E L S R E L A Y S B I N A R Y I N P U T M O D B U S S L A V E C U R R E N T O U T P U T Select RELAY1 to RELAY4 items to set the configuration of relays. Each relay can work in several modes: Direct manual control Alarm function Pulse output function Using the DIRECT MANUAL item, the relay can be controlled manually. If you set maximum flow rate value in the ALARM item, you enter to the alarm function. When this value is exceeded, appropriate relay is activated. When you set WIDTH PULSE and QUANTITY values in the PULSE OUTPUT item, you enter to the pulse output mode. In the WIDTH PULSE item, you can set the pulse width from 0.1 to 9.9 s. In the QUANTITY item, you can set flown amount to generate the pulse. In the INVERT item, you can select whether the relay is in normal mode (active relay switched on, inactive switched off), or in the inverse mode (active relay switched off, inactive switched on). In the SOURCE item, you can select a channel the relay function is associated with. 8.4.4. Network interface setup The network interface setup is only for FCU-400-R_-W version. The network interface setup can completely be done using a web interface. 8.4.5. Binary input setup Binary inputs can be set in CONFIGURATION/IO CHANNELS/BINARY INPUT. In this menu, you can select a user totalizer to be reset to zero during the activation of the binary input. Make the selection by pressing the button next the required item. See more about totalizers in chapter 7.5.2 I O C H A N N E L S 1 I N P U T C H A N N E L S R E L A Y S B I N A R Y I N P U T M O D B U S S L A V E C U R R E N T O U T P U T B I N A R Y I N P U T 6 4 C L E A R T O T A L I Z E R 1 C L E A R T O T A L I Z E R 2 C L E A R T O T A L I Z E R 3 C L E A R T O T A L I Z E R 4 17

8.4.6. Communication parameters setup for modbus rtu / rs-485 slave Complete setup of RS-485 line communication parameters and device address in the Modbus RTU(Slave) protocol can be made in the CONFIGURATION/IO CHANNELS/MODBUS SLAVE menu. a) Communication rate setup I O C H A N N E L S 1 I N P U T C H A N N E L S R E L A Y S B I N A R Y I N P U T M O D B U S S L A V E C U R R E N T O U T P U T The communication rate can be set in the BAUD RATE menu. M O D B U S S L A V E 9 5 B A U D R A T E F O R M A T 1 9 2 0 0 Select the required communication rate using button from values of 4200, 9600, 19200, and 38400 Bd/s. When the button is pressed, selected communication rate is saved, and you will return to the previous menu. When you press button, you will return to the previous menu without saving the setup. b) Communication format setup The communication format can be set in the FORMAT mode. M O D B U S S L A V E 9 5 B A U D R A T E F O R M A T 8 N 1 You can select required format using button from 8N1, 8N2, 8E1, 8E2, 8O1, and 8O2 types. When the button is pressed, selected communication format is saved, and you will return to the previous menu. When you press the button button, you will return to the previous menu without saving the setup. c) Device Modbus address setup The Modbus address of the device can be set in the ADDRESS menu. M O D B U S S L A V E 9 5 B A U D R A T E F O R M A T I N S E R T V A L U E ( H E X ) 0 0 0 1 You can select required address from 0x01 to 0xF7(247 dec). When the button is pressed, the set address is saved, and you will return to the previous menu. When you press the button button, you will return to the previous menu without saving the setup. 8.4.7. Current output parameters setup Complete current output parameters can be set in CONFIGURATION/IO CHANNELS/CURRENT OUTPUT menu. a) Minimum flow rate setup I O C H A N N E L S 1 I N P U T C H A N N E L S R E L A Y S B I N A R Y I N P U T M O D B U S S L A V E C U R R E N T O U T P U T Minimum flow rate corresponding to the minimum current at the output can be set in the MIN FLOW item. C U R R E N T O U T P U T 1 0 7 M I N F L O W M A X F L O W S O U R C E T Y P E I N S E R T V A L U E 3 + 0 0 0 0 0 0. 0 0 0 0 m E EN N T 18

a) Maximum flow rate setup Maximum flow rate corresponding to the maximum current at the output can be set in the MAX FLOW item. C U R R E N T O U T P U T 1 0 7 M I N F L O W M A X F L O W S O U R C E T Y P E I N S E R T V A L U E 3 + 0 0 0 1 0 0. 0 0 0 0 m E EN N T c) Source channel setup The SOURCE item is used to set the source channel, the current output is associated with. C U R R E N T O U T P U T 1 0 7 M I N F L O W M A X F L O W S O U R C E T Y P E C H A N N E L 1 E EN N T d) Current output type setup The current output type can be selected in the TYPE item. You can select between the scope of 0-20 ma, and 4-20 ma, with current error of 3.75 ma or 22 ma. 8.4.8. General settings C U R R E N T O U T P U T 1 0 7 M I N F L O W M A X F L O W S O U R C E T Y P E a) Main screen type setup S E L E C T T Y P E 0-2 0 m A E R R : 2 2 m A E EN N T The main screen type can be set in CONFIGURATION/DISPLAY MODE menu. When you access this item, you can select from two displays: FLOW, or FLOW+TOTALIZER. C O N F I G U R A T I O N 2 I / O C H A N N E L S D I S P L A Y M O D E P A S S W O R D D A T E / T I M E F A C T O R Y D E F A U L T D I S P L A Y M O D E 1 0 3 F L O W F L O W + T O T A L I Z E R When you select the FLOW item, actual flow rate is displayed on the screen. D I S P L A Y M O D E 1 0 3 F L O W F L O W + T O T A L I Z E R When you select the FLOW+TOTALIZER item, actual flow rate is displayed on the screen together with the totalizer state. D I S P L A Y M O D E 1 0 3 F L O W F L O W + T O T A L I Z E R b) Access password change The access password can be changed in the CONFIGURATION/PASSWORD menu. When you enter this item, you are asked to re-enter your user password. C O N F I G U R A T I O N 2 I / O C H A N N E L S D I S P L A Y M O D E P A S S W O R D D A T E / T I M E F A C T O R Y D E F A U L T I N S E R T P A S S W O R D? 19

When the password is entered incorrectly, "INCORRECT" text is displayed, and by pressing the button "INSERT PASSWORD" text is displayed again to enter the password or return to the previous menu. When you enter correct password, a field for the access password change shows up with the existing password as its default. By pressing the button, numbers can be browsed. Current position is highlighted. By pressing the button, numbers to the current position can be entered in the range of 0 to 9. By pressing the button, the password is confirmed. I N S E R T V A L U E 1 2 3 4 c) Date and time setup Date and time can be changed in the CONFIGURE/DATE-TIME menu. When you access this item, current date and time are displayed. By pressing the button, positions can be browsed. Current position is highlighted. By pressing the button, number to the current position can be set. By pressing the button, date and time are confirmed. At the moment you press the button, second counter is reset to zero. C O N F I G U R A T I O N 2 I / O C H A N N E L S D I S P L A Y M O D E P A S S W O R D D A T E / T I M E F A C T O R Y D E F A U L T I N S E R T D A T E / T I M E 1 4. 0 1. 1 4 1 0 : 0 5 d) Restoring the evaluation unit to the factory default The factory defaults can be restored in the CONFIGURE/FACTORY DEFAULT menu. When you access this item, "ARE YOU SURE?" shows on the display. By pressing the button you will return to the previous menu. By pressing the button, the factory defaults will load, and you will return to the previous menu. C O N F I G U R A T I O N 2 I / O C H A N N E L S D I S P L A Y M O D E P A S S W O R D D A T E / T I M E F A C T O R Y D E F A U L T F A C T O R Y D E F A U L T A R E Y O U S U R E? After the activation of this function, all parameters of the unit are restored to the default state (including access password). Records of statistics, totalizers and operating hours remain unchanged!!! 8.5. Reading statistical data The FCU-400 evaluation unit is equipped with internal FLASH memory for storing average 5-minute flow rate values regularly from all channels. In addition to these average flow rate values, each channel's operating hours are stored in the FRAM memory as well as zero non-resettable counters of the total flown amount in each channel, so called totalizers. 8.5.1. Recording average 5-minute flow rate values Each record of average 5-minute flow rate values includes date and time of the record, flow rate value with corresponding set unit and, measurement time within the relevant 5-minute section (in seconds). These values are stored for all channels. Thus, evaluation unit allows for browsing flow history up to the last 15 months. These records can be read in three ways: a) On the display In the STATISTIC/VIEW STATISTIC menu, select 5-MIN FLOW item. After you access this item, enter required record date and time, you want to show on the display. Time can only be entered as a required hour. V I E W S T A T I S T I C 6 5 5 - M I N F L O W 20

After you press the button, required record is searched for. During the search, the upper part of the display shows text "LOADING ". When the required record is found, it is shown on the display. Then, the first found record for the set hour shows on the display. I N S E R T D A T E / T I M E 0 8. 0 1. 1 4 1 0 H 3 C H 1 - m / s 0 8. 0 1. 1 4 1 0 : 0 5 F L O W = 0. 5 6 5 T I M E = 3 0 0 S E C E N T The record mentioned above had the following meaning: On January 8 2014, within the period of time 10:00 10:05, the average flow rate in channel 1 was 0.565 m3/s. The measurement took place for 300 s, i.e. 5 minutes. During this 5-minute record, no measurement error occurred. To move to the next record, please, use the button. button. To display recorded data for other channels, please, use the When no record is found, "NOT FOUND" shows on the display. C H 1 - N O T F O U N D E N T By pressing the button you can return to the previous menu. b) Copying all records to USB Flash Disk In the STATISTIC menu, select COPY STAT. TO USB item. When you access this item, you are prompted to insert the USB Flash Disk to USB connector. S T A T I S T I C 6 3 V I E W S T A T I S T I C C O P Y S T A T. T O U S B V I E W T O T A L I Z E R S C O P Y S T A T I S T I C I N S E R T F L A S H D I S C E N T When the disk is inserted, all records are copied to the portable medium. During copying, per cent progress is shown on the display. C O P Y S T A T I S T I C C O P Y I N G... 1 3 % E N T This action can be cancelled any time by pressing the button. When the copying is completed, "COMPLETED" shows on the display. C O P Y S T A T I S T I C C O M P L E T E D E N T When you remove the USB disk without proper completion, the stored file may be damaged. Copied data is stored in the CSV format file named FCU400.csv. c) Reading records using RS-485 Modbus RTU-Slave communication channel Any recorded data can be read using the RS-485 communication interface with Modbus RTU-Slave protocol. 21

8.5.2. Function of totalizer and operating hours For each measuring channel, the evaluation unit includes two flown amount counters - totalizers. The first (factory) totalizer is used to count flown amount during the device lifetime, and cannot be reset to zero. The second totalizer (user) is used to count the flown amount, and can be reset to zero. These user totalizers can be reset to zero directly in menu, or by a connected button to binary input (see chapter 7.4.5) Totalizers and operating hours can be displayed in the STATISTIC/VIEW TOTALIZERS menu. When you access this menu, channel 1 factory totalizer and channel 1 operating hours are displayed. S T A T I S T I C 6 3 V I E W S T A T I S T I C C O P Y S T A T. T O U S B V I E W T O T A L I Z E R S F : T : T O T A L I Z E R 1 - F A C T O R Y 3 2 4 8 3 5 9 8 m 5 D A Y S 0 0 : 0 1 E N T By pressing the button, channel 1 user totalizer is shown, resettable to zero using the E CN LTR button. T O T A L I Z E R 1 - U S E R F : 3 0. 0 0 0 m E CN LTR By pressing the button again, you can browse all totalizers for all channels. 8.6. Other information 8.6.1. Displaying current date and time Current date and time can be displayed in the main menu under the DATE/TIME VIEW item. M A I N M E N U 0 S T A T I S T I C C O N F I G U R A T I O N D A T E / T I M E V I E W P A S S W O R D C H E C K D I A G N O S T I C D A T E / T I M E 1 3. 0 1. 1 4 1 0 : 1 1 E N T By pressing the button, you will return to the main menu. 8.6.2. Displaying information about the evaluation unit Information about the FCU-400 evaluation unit can be displayed in the main menu under the INFO item. M A I N M E N U 0 S T A T I S T I C C O N F I G U R A T I O N D A T E / T I M E V I E W P A S S W O R D C H E C K D I A G N O S T I C When you access this item, the evaluation unit type, serial number, and firmware version number are displayed. By pressing the button button, you will return to the main menu. After the unit setup completion, it is recommended to RESET (CONFIGURATION / RESET), and verify correctness of preset parameters!) 22

9. Marking methods FCU 400 R power supply voltage: outputs: binary outputs: 230 V 100.. 240V AC 24 V 9.. 36 V DC 0 without web server and without current output W web server I current output 0 0x without relay outputs 2 2x SSR relay outputs (RE 1 and RE 2) 4 4x SSR relay outputs (RE 1 to RE 4) 10. Examples of correct marking FCU-400-R4-W-24 (R4) SSR relay outputs; (W) including web server; (24V) power supply voltage 9.. 36V DC. FCU-400-R0-0-230 (R0) without relay outputs; (0) without web server, and without current output; (230V) power supply voltage 100.. 240V AC. 12. Protection, safety, and compatibility Both power supply version of the unit are protected with internal fuse. Electric equipment of protection class II. Electric safety as per ČSN EN 61010-1. Electromagnetic compatibility (EMC) is ensured in compliance with ČSN EN 55022 a ČSN EN 61000-4-2, -3, -4, -5, -6-11 standards 11. Usage, operation, and maintenance The flowmeter does not require any operating personnel. During operation, the technological part operating personnel is informed about the liquid flown amount using a consequent display device and at the place of the flowmeter installation. The maintenance of the device is based on the flowmeter and supply cable undamaged state inspection. Depending on nature of measured liquid, it is recommended every one year to inspect cleanliness of internal measuring electrodes, and clean them as needed. When any visible defects are detected, promptly contact manufacturer or dealer of the equipment. No modifications or interventions to the FCU-400 flowmeter are allowed without the manufacturer's approval. Repairs, if any, shall only be done at the manufacturer or authorized service organization. Assembly, installation, commissioning, and maintenance of the FCU-400 flowmeter shall be performed in compliance with this user's guide, and applicable standards for the installation of electric equipment shall be observed. 13. Marking labels Flowmeter sensor label data FCU-400-R_-_-230V manufacturer mark: Dinel logo internet address: www.dinel.cz flowmeter type: FCU-400-R_-_-230V product serial number: Ser. No.: xxxxx (from the left: year of production, consequential serial number) power supply voltage: U = 100.. 240 V AC / 50.. 60 Hz nominal input power: P = 10 VA working temperature range: t a = -30... +50 C sensor coverage: IP65 double insulation mark (protection class II device): conformity mark: electric waste return mark: Dinel www.dinel.cz Made in Czech Republic FCU-400-R_-_-230V U = 100... 240 V P = 10 VA t a = -30... +50 C / 50... 60 Hz Ser. No.: 23

Flowmeter sensor label data FCU-400-R_-_-24V manufacturer mark: Dinel logo internet address: www.dinel.cz flowmeter type: FCU-400-R_-_-24V product serial number: Ser. No.: xxxxx (from the left: year of production, consequential serial number) power supply voltage: U = 9.. 36 V DC nominal input power: P = 8 VA working temperature range: t a = -30... +50 C Dinel sensor coverage: IP65 double insulation mark (protection class II device): www.dinel.cz Made in Czech Republic conformity mark: electric waste return mark: FCU-400-R_-_-24V U = 9... 36 V P = 8 W t a = -30... +50 C Ser. No.: 14. Specifications Basic specifications Case - material Dimensions Protection class FCU-400 ABS 160x166x106 mm IP65 Working temperature -30... + 60 C Power supply voltage Nominal input power 230 V option 24 V option 230 V option 24 V option 100-240V AC 9-36V DC max. 10VA max. 8VA Outputs 0, 2 or 4 SSR relays, max. 250 V AC / 100mA (24 V DC / 100mA) (alarm function, pulse output, manual control) RS 485 / Modbus RTU - Slave, galvanic separation Ethernet / RJ45 (optional) Current output 0/4-20 ma (optional) Inputs RS 485 / Modbus RTU - Master, galvanic separation (max. 4 sensors) Binary input for resetting user flow rate counter to zero (for voltage free contact) USB Internal power supply source for sensors Type of display Controls Internal memory capacity for data archiving Display functions Totalizer function Us = 24 V DC / Imax. 120 ma Matrix OLED display, 128x64 pixels Foil keyboard - 4 buttons Continuous archiving of average 5-minute flow rate values for at least 15 month Display actual flow rate value with graphical representation in bar graph Simultaneously display actual flow rate, state of relay outputs and state totalizer 2 counters of total flown amount in each channel (1x resettable, 1x non-resettable) 24

industrial electronics Dinel, s.r.o. U Tescomy 249 760 01 Zlín Czech Republic Tel.: +420 577 002 003 Fax: +420 577 002 007 E-mail: sale@dinel.cz www.dinel.cz The lastest version of this instruction manual can be found at www.dinel.cz Version: 6/2015