The Impulse Design of Transformer Oil-Cellulose Structures

Similar documents
THE APPROACH TO THE ANALYSIS OF ELECTRICAL FIELD DISTRIBUTION IN THE SETUP OF PAPER INSULATED ELECTRODES IN OIL

OR Explain thermal breakdown in solid dielectrics. How this mechanism is

COMPARATIVE EVALUATION OF BREAKDOWN STRENGTH OF NATURAL ESTERS AND MINERAL OIL

STUDIES ON LIGHTNING CHARACTERISTICS

EXPERIMENTAL DEVELOPMENTS ON SOIL IONIZATION: NEW FINDINGS

Fatima Michael College of Engineering & Technology

DETERMINATION OF THE DIELECTRIC STRENGTH OF LPS COMPONENTS BY APPLICATION OF THE CONSTANT-AREA-CRITERION

Analysis of Very Fast Transients in EHV Gas Insulated Substations

Modeling of Degradation Mechanism at the Oil-Pressboard Interface due to Surface Discharge

A New Model of Investigating the Electric Field in Dielectric Liquid for Streamer Initiation

with embedded electrode

Dynamics of streamer propagation in air

O Plus Dry Bushing 69 kv system, 350 kv BIL, 3000 A. Table of contents

BREAKDOWN STUDY OF WATER WITH DIFFERENT CONDUCTIVITIES

CIGRE SC A2 & D1 JOINT COLLOQUIUM 2011, KYOTO JAPAN. Water Saturation Limits and Moisture Equilibrium Curves of Alternative Insulation Systems

Modern Electrical Diagnostics for Metal Oxide Surge Arresters

HUMIDITY INFLUENCES ON THE BREAKDOWN OF ROD-PLANE GAPS UNDER POSITIVE IMPULSES IN ATMOSPHERIC AIR

Copyright 2014 IEEE. Paper presented at 2014 IEEE conference on electrical insulation and dielectric phenomena, Des Moines, USA, October, 2014.

Comparison of Partial Discharge Characteristics for Different Defect Types in SF 6 Gas Insulation System

The leader propagation velocity in long air gaps

THE ELECTRICAL BREAKDOWN CHARACTERISTICS OF OIL/PAPER INSULATION UNDER FAST FRONT IMPULSE VOLTAGES MENGGUANG WANG

O Plus Dry Bushing 25 kv system, 150 kv BIL, 3000 A

An Optimised High Current Impulse Source

HIGH ENERGY DENSITY CAPACITOR CHARACTERIZATION

Capacity calculation of the electrotechnical scheme of discharge gap replacement of the ozonizer in the СOMSOL environment

On Designing of a High Voltage Standard Capacitor Using a Semi-Analytical Field Computation Method

An Innovative Simple Test Circuit for Single-Phase Short Circuit Making Test of High-Voltage Switching Devices

UNIT I - INTRODUCTION SYLLABUS

Simulation of Prebreakdown Phenomena in Air Gaps of Rod Plane Configuration of Electrodes

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY HIGH VOLTAGE ENGINEERING

Advanced Technique for Dielectric Analyses

Comparison of Finite Element Analysis to IEC for Predicting Underground Cable Ampacity

THE EFFECT OF REVERSAL ON CAPACITOR LIFE

30. BREAKDOWN IN DIELECTRICS WITH DEFECTS

NUMERICAL ANALYSES OF ELECTROMAGNETIC FIELDS IN HIGH VOLTAGE BUSHING AND IN ELECTROMAGNETIC FLOW METER

Effect of Temperature on Condition Assessment of Oil-Paper Insulation using Polarization- Depolarization Current

Formation of white-eye pattern with microdischarge in an air. dielectric barrier discharge system

CHAPTER 2 ESTIMATION OF BREAKDOWN VOLTAGES IN SMALL INSULATION GAPS AN EMPIRICAL APPROACH

An Empirical Formula for the Surge Impedance of a Grounding Conductor along a Reinforced Concrete Pole in a Distribution Line

Recent Improvements in K-Factor Models

IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 18, NO. 4, OCTOBER

Modelling Of Mathematical Equation for Determining Breakdown Voltage

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

The Effect of the Over Voltage on the Stress Distribution at the Terminals of H.V. XLPE Cables. Professor

Solution for High Voltage Engineering

Effect of High Voltage Impulses on Surface Discharge Characteristics of Polyethylene

To the electrostrictive mechanism of nanosecond-pulsed breakdown in liquid phase

Optimization of High Voltage Arc Assist Interrupters

Modeling of Transmission Line and Substation for Insulation Coordination Studies

A Simulation Model of Fluid Flow and Streamlines Induced by Non-Uniform Electric Field

Code No: RR Set No. 1

SPECIFICATION AND PERFORMANCE CHARACTERISTICS OF SCA-2 CONNECTOR SERIES


The ESD5451R is available in DFP1006-2L package. Standard products are Pb-free and Halogen-free. Circuit diagram

UPDATE ON ACCELERATED AGEING OF MV XLPE

Modeling Electric Fields in High Voltage Submersible Changeover Switch

TEST CERTIFICATES OR REPORTS ISSUED BY VEIKI-VNL LTD.

Measurement of the electric field at the near field radiating by electrostatic discharges

Numerical Simulation of Townsend Discharge, Paschen Breakdown and Dielectric Barrier Discharges Napoleon Leoni, Bhooshan Paradkar

EHD flow produced by positive and negative point-to-plate corona discharges

PIV Measurements of the Influence of Seeding Particles Concentration on the Velocity of an EHD Flow

Keywords- Metal Oxide Surge Arrester, Model, Transient, Laboratory Experiment, Simulation.

The Impact of Metallized Electrodes on High Energy Density Pulse Power Capacitors

IEC Type Test Report Report No. EU1527-H-00.1 PH3 Series Polymer-housed Arrester 10,000 A Line Discharge Class 3

Electric Filed Simulation and Structure Optimization for 40.5kV GIS Based on Finite Element Method

Electrical Breakdown Properties of Oil-paper Insulation under Pulsating Voltage Influenced by Temperature

PHYS 241 EXAM #1 October 5, 2006

Lawrence Livermore National Laboratory Livermore, CA USA 2. Tomotherapy, Inc. Madison, WI USA 3

EE 427 High Voltage Breakdown & Testing Model Answers. Level 4 Semester 2 Examination - February 2009 Answer 1. anode (+) 2 marks. 3 marks.

Physics (

FEATURES APPLICATIONS DESCRIPTION QUICK REFERENCE DATA. PILKOR components

Equipotentials and Electric Fields

ELECTRICAL BREAKDOWN OF SHORT NON-UNIFORM AIR GAPS M. G. Hogg, I. V. Timoshkin, S. J. MacGregor, M. P. Wilson and M. J. Given, T.

THE EARLY STREAMER EMISSION PRINCIPLE DOES NOT WORK UNDER NATURAL LIGHTNING!!

Finite Element Model of a Magnet Driven Reed Switch

Experimental study of dynamic thermal behaviour of an 11 kv distribution transformer

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

A Novel Optimized Design for Busbar Structures using Finite Element Methods

Electric Field Stress Calculation on High Voltage Insulator

COUPLED MAGNETO-MECHANICAL FINITE ELEMENT ANALYSIS OF A POWER TRANSFORMER IN SHORT CIRCUIT CONDITIONS

TYPE. max. working voltage 250 V 350 V 500 V 750 V. max. overload voltage 500 V 700 V 1000 V 1500 V. basic specifications IEC B

Preliminary study on the modeling of negative leader discharges

High Voltage Capacitors Designed to Avoid Catastrophic Failure Modes

I to assess the breakdown probability of the various insulation

Exponential Expression of Relating Different Positive Point Electrode for Small Air Gap Distance

INSTITUTE OF AERONAUTICAL ENGINERING DUNDIGAL ELECTRICAL AND ELECTRONICS ENGINEERING

Consider a point P on the line joining the two charges, as shown in the given figure.

Comparison between cut and try approach and automated optimization procedure when modelling the medium-voltage insulator

Super High AUTO (SHA) Series

EXPERIMENTAL STUDY OF SHOCK WAVE INTERACTING PLANE GAS-PLASMA BOUNDARY

RC Studies Relaxation Oscillator

Simulation of Partial Discharge in Solid Dielectric Material

The Impact of Distributed Generation on Power Transmission Grid Dynamics

Electric Field Measurements in Atmospheric Pressure Electric Discharges

Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2

Mechanisms for Degradation of TR-XLPE Impulse Strength During Service Aging

Product Data Sheet PD-0053-A

Standard Practice for Heat Aging of Plastics Without Load 1

(2011) 18 (4) ISSN

NECESSARY SEPARATION DISTANCES FOR LIGHTNING PROTECTION SYSTEMS - IEC REVISITED

Transcription:

IEEE Transactions on Dielectrics and Electrical Insulation Vol. 13, No. 3; June 2006 The Design of Transformer Oil-Cellulose Structures J.K. Nelson and C. Shaw Rensselaer Polytechnic Institute. Dept. of Electrical, Computer and Systems Engineering Troy, NY 12180-3590, USA ABSTRACT Transformer oil/cellulose structures are often designed based on a cumulative stress criterion derived from experimental tests at power frequency. However, such structures must also meet stringent impulse requirements defined by a Basic Insulation Level (BIL). The industry has tried to establish an equivalence factor to permit power frequency cumulative stress methods to be used to estimate impulse withstand strength. Since the mechanisms of failure differ substantially under surge conditions, there would seem no good reason to suppose that a universal equivalence factor is appropriate. Tests are reported using a 2.3 MV generator to document impulse failure of a number of bulk, creep and hybrid structures to establish the nature of this relationship through statistical comparisons with the established 50/60 Hz methods. Factors varied from 1.94 to 3.34, depending on the configuration. The methodology is described and the results discussed in the context of the design of oil-cellulose structures, having regard to complicating factors such as waveshape and electrode covering. The study permits some speculation about impulse design under hybrid situations (i.e. failure paths involving both creep and bulk liquid). Index Terms Insulation design, oil/cellulose structures, cumulative stress, impulse withstand. 477 1 BACKGROUND THE cumulative stress method is in industrial use for the design of composite (oil-paper) structures, particularly for large transformers. It has evolved to provide a design tool for use under alternating voltage conditions and is based on numerous experimental test results. The economic design of complex liquid-solid dielectric structures in divergent electric fields is problematic since the electric stresses involved are usually substantially non-uniform, may not change monotonically, and a plurality of materials and geometries are prevalent. Furthermore, the problem is further complicated by the combined nature of many of the critical paths (i.e. part creep, part bulk). Despite the semi-empirical nature of the method, there is a theoretical basis for the technique [1] based on known physics when applied for 50/60 Hz stresses. The method has served the transformer industry well, and avoids establishing a withstand voltage simply on the basis of the maximum prevailing electric field which is clearly an ineffective and uneconomic criterion. 1.1 THE CUMULATIVE STRESS CRITERION In applying the cumulative stress technique, the structure is examined and paths thought to be critical are identified. Such Manuscript received on 14 September 2005, in final form 14 November 2005 paths may be categorized as either bulk through oil volumes, creep along cellulose surfaces (paper or pressboard) or some combination of the two. The prevailing electric field is computed along each chosen path, usually by the application of finite element flux plotting software. Starting at the point of highest stress (which is usually at one end of the path, but not always so), the stress is calculated over a fixed increment in the direction which maximizes the stress. In a stepwise manner, the track is extended along the path by considering each successive increment and computing the largest cumulative stress i.e. the total voltage divided by the corresponding portion of the path. The resulting profile (cumulative stress as a function of position on the path) is then compared with design curves used by individual industrial designers. An example taken from Moser [2] is depicted in Figure 1 for bulk oil and creep paths under 50/60 Hz ac stresses. A detailed example of the method may be studied in [3] which describes the development of a computer-based algorithm to automate the process A profile which is totally under the respective design curve is deemed to be a satisfactory design, and, conversely, if any part of the profile lies above the curve, the design (for that path) is considered unsafe. The margin of safety can be assessed from the relative positions of the curves. It is important to recognize that 1070-9878/06/$20.00 2006 IEEE

478 J.K. Nelson and C. Shaw: The Design of Transformer Oil-Cellulose Structures Electric Field (kv/cm) 1 10 100 1000 this is a design criterion and not a breakdown estimate. Statistical margin is already built into the design curves which represent approximately a 1% failure probability. Figure 1 represents the two basic criteria for bulk and creep cases. However, in practice, additional curves are sometimes used to allow for gas content, electrode covering, non-continuous operation, etc. An interesting feature of the bulk cumulative stress curve is that its power law relationship may be expressed as: E = 75 d 0.38 (1) Where d is the oil path length. It may also be shown that the volume effect [1,4] associated with oil breakdown may also be defined empirically as E v 0.137, where v is the volume within a 90% equigradient contour. This would imply that, for example, a plane parallel gap would exhibit an area which increased approximately as the square of the gap spacing. This is clearly erroneous unless the volume involved is not that between the electrodes, but rather a hemispherical volume surrounding each initiating event at the electrode. In these circumstances the two representations are entirely compatible. Such a description is also thus consistent with a weak link theory of breakdown which can be represented by one of the asymptotic distributions of extreme values [5] as given in Section 2.3. The nature of Figure 1 explains why liquids are particularly weak when path lengths are long, and why barriers are effective in improving dielectric integrity. 1.2 IMPULSE FAILURE Under impulse conditions, it is clear that some of the mechanisms known to influence power frequency breakdown are inoperative. Clearly, those agencies which require a considerable period of time to operate such as electrohydrodynamic motion producing flow-induced cavitation, dielectrophoretic particle migration, large bubble formation etc. will effectively be frozen out leaving fast processes like streamer propagation as likely mechanisms. Asa result, many of the mechanisms which are known to trigger (a) (b) 0.10 1.00 10.00 100.00 Path Length (cm) Figure 1. Power Frequency ac rms design curves for (a) bulk oil, (b) creep. breakdown under sustained voltages and underlie the design curves in Figure 1 will no longer be relevant. There are no curves that are equivalent to Figure 1 which pertain to impulse failure, and, indeed if the physical basis for the form of Figure 1 is taken into account, there are good reasons for surmising that the cumulative stress method would not be likely to provide a valid basis for impulse design. DIL Factor 3 2.5 2 1.5 1 0.5 0 2.5 - Full Wave 1.7- Switching 1 - Applied 0.8 - Induced 1.E-06 1.E-04 1.E-02 1.E+00 1.E+02 1.E+04 Time (s) Figure 2. Design Insulation Levels (factors) for typical ANSI dielectric tests. Notwithstanding that, the transformer industry needs to be able to account for impulse breakdown in the design in order to insure that the structures meet the Basic Insulation Level (BIL). One common method of design assessment is to use the power frequency criteria with a factor to account for the surge conditions. The factor is varied according to the duration of the impulse applied. This factor is known as the Design Insulation Level (DIL). A plot of the DIL versus the time duration of the applied voltage is given in Figure 2. However, the obvious differences in breakdown mechanism calls into question the use of a constant conversion factor for any insulation system. Clearly, a comprehensive empirical study to document this relationship would be a formidable undertaking. The results reported here provide a modest start in the process of providing a better basis for the impulse design of composite structures. 2 EXPERIMENTAL ARRANGEMENTS 2.1 TEST STRUCRURES In order to represent a number of different breakdown path configurations, eight different test structures (designated A H) were developed and are described in Table 1. These provide for breakdown paths which are predominantly through bulk oil, along creep surfaces or mixed configuration situations (i.e. failure paths where

IEEE Transactions on Dielectrics and Electrical Insulation Figure 3. Three of the 8 oil-cellulose structures. Table 1. Descriptions of the structures. Creep A B C D Bulk Oil E F Combination G H 479 Vol. 13, No. 3; June 2006 4 cm x 10 cm cylinder with 2 cm standoffs holding the rings 2 cm cylinder cut to 5 cm in length between disc electrodes 2 cm cylinder cut to 8 cm between disc electrodes 2-2x2.7 cm cylinders separated by 6 mm x 3 cm pressboard disc between disc electrodes for that [2] when applying the design criteria as discussed in Section 4. 2.2 PULSE SOURCE The structures were accommodated in a sealed oilfilled cell, with optical windows, which in turn was mounted on the oil-filled high-voltage termination of a 2.3 MV Febetron providing a steep-fronted impulse (0.024/3.2 µs waveshape). The test enclosure is depicted in Figure 4. This generator was a 160-stage Marx circuit (modified to operate at only half its voltage capacity) in a grounded enclosure insulated with Freon -12 gas. The rig was controlled with a trigatron on the first stage together with voltage control through N2 stack pressure adjustment. The negative-going applied voltage and waveform were determined by a 500 MHz digitizing oscilloscope coupled through a matched 32,000:1 built-in divider. Where the impulse failure occurred on the 1.59 cm oil gap between disc electrodes 2.86 cm oil gap between disc electrodes 2 cm x 10 cm cylinder with 1 cm standoffs holding the rings 2 cm x 10 cm cylinder with 2 cm standoffs holding the rings. part is creep and part is through bulk liquid). Three typical examples are depicted in Figure 3. The samples were primarily based on pressboard cylinders placed between contoured electrodes and vacuum oil impregnated to usual industrial standards. By using two different diameters of pressboard tube (4 cm and 2 cm), it was possible to provide a pure creep surface or a combination of bulk oil and surface creep (for the 2 cm cylinder where the pressboard was not in intimate contact with the doughnut-shaped metallic ring see Figure 3 right-hand image.). The structures were immersed in a standard transformer oil (Shell Diala B) with a moisture content of 7 ppm determined by a Karl Fischer electrometric titration. The oil was filtered through a 1 µm edge filter and degassed to 1.3 Pa (10-2 Torr) in a degassing chamber in which the oil made multiple passes down plates in the vacuum enclosure at 70 C. The known difficulties [6] of lapped paper insulation on the electrodes prompted the use of bare electrodes in this study. However, proper allowance was made Figure 4. Test enclosure mounted on the terminal of the 2.3 MV Febetron. outside of the structure, a camera system (not shown in Figure 4) was able to document the breakdown path through the windows provided. It is recognized that the impulse tests were not undertaken with a standard 1/50 µs wave which would have been desirable. However the unique multi-mv impulse generator available was not capable of front and tail time extended to the standard waveshape. The implications of the non-standard wave are further discussed in Section 4. 2.3 PROCEDURES To determine the impulse characteristics, samples were tested according to the step up method [7], where the actual breakdown voltage value was recorded. The parameter estimates, were obtained from a Weibull

480 J.K. Nelson and C. Shaw: The Design of Transformer Oil-Cellulose Structures analysis with a maximum likelihood algorithm. The actual tests usually consisted of 30 samples per structure to obtain a statistically meaningful result. The 1% impulse value was then determined by rearranging the Weibull cumulative distribution function as follows: Given, then: P ( x ) 1 exp (2) α = β 1 α( ln( 1 P) ) β x = (with P = 0.01) (3) where x is the value of the breakdown voltage that gives probability P, and α and β are the Weibull scale and shape parameters, respectively. Design curves similar to those in Figure 1 were used to determine the 1% ac breakdown values for each of the eight structures studied. This was done with the proper accounting of the bulk and/or creep paths and the absence of electrode covering where applicable. The prevailing electric fields were Electrode ring extension to create composite path Main disc electrode 3 RESULTS Descriptive statistics were gathered for each of the structures considered and 90% confidence intervals computed for the α and β parameters. On the basis of the accumulated and processed data, Table 2 was established which summarizes the data for the various structures grouped according to their type. There is a presumption that the data are represented by a Weibull distribution. In order to determine the goodness Table 2. Experimental impulse-to-ac ratios. Structure Structures with rings Calc. 1% ac Breakdown Value (kv) Exptl. 1% Neg. Breakdown Value (kv) to ac Ratio A 157.5 346.0 2.19 G 212.5 526.5 2.48 H 187.5 495.0 2.49 Structures w/o rings B 137.5 400.0 2.71 C 177.5 506.0 2.84 F 135.0 460.0 3.34 E 92.5 195.0 2.00 D 162.5 341.0 1.94 Cylinder Figure 5. Flux plot of the composite path appropriate to Structure H. determined by flux plots, such as that illustrated in Fig. 5 and a program developed in FORTRAN that uses the output of a finite element program to determine the cumulative stress and associated margins [3]. Figure 5 depicts a combination (bulk oil + surface creep) case in which the discharge path can be partly across a surface and partly through series oil path(s). The equipotential lines are asymmetrical as a result of the grounded end of the test enclosure, which may make the breakdown somewhat polarity dependent. The automatic computation of cumulative stress was undertaken for the critical paths for each particular structure and the voltage level in the finite element analysis was adjusted until the margin was zero for each structure. This voltage was taken as the 1% ac breakdown value on which the design is (arbitrarily) based. of fit of the estimated parameters, a chi-squared goodness-to-fit test [8] with six equiprobable bins was applied to the data of each structure. Most fits yielded χ 2 values of about 80% although, notably, structures B, D, and G were significantly worse. However, all the structures generated better fits to a Weibull distribution than to a normal curve. Not all the 30 samples of each structure failed in the same way. There was usually a predominant mechanism which has been summarized in Table 3. It is significant, however, that those breakdowns which occur in a nonpredominant way also often have a breakdown voltage which is anomalous. For example, Structure A usually failed by creep exhibiting a characteristic value of 929 kv. However, 4 samples did exhibit punctures and these had strengths as low as 380 kv which significantly depress the ratios in Table 2.

IEEE Transactions on Dielectrics and Electrical Insulation Vol. 13, No. 3; June 2006 Table 3. Summary of predominant failure modes. Structure A Predominant Failure Mechanism Outer surface punctures B C D E F G H creep, with (b) 2 (c) Figure 6. Physical evidence for creep and puncture failures. (a) Outer cylinder creep (Structure A), (b) Inner cylinder creep (Structure B), (c) Puncture (Structure A). These failure modes may be further visualized by undertaking a tear-down analysis and by examining the optical records obtained during the experiment. As an example, Figure 6a depicts external creep damage typical of Structure A and Figure 7a shows the corresponding optical breakdown image typical of the creep phenomenon for that structure. However, Table 3 also indicates that a few of the failures of Structure A also resulted in puncture of the cylinders. This is depicted in Figure 6c. Similarly, the internal failure pattern is (a) (b) shown in Figures 6b and 7c which corresponds to Structures B and C. 4 DISCUSSION AND IMPLICATIONS some Inner surface creep Inner surface creep Inner surface creep + barrier creep Short paths; very variable Short paths; very variable Bulk oil between rings Bulk oil, but with some creep occurring (a) 1 481 By establishing the characteristic impulse failure voltages and comparing them with the equivalent power frequency computations, estimates of the conversion factors have been obtained for the 8 different configurations studied based on a 1% failure probability obtained from the Weibull statistics. Factors varied from 1.94 to 3.34 depending on the configuration. These limits certainly encompass the factor (2.5) typically used for 1/50 µs surges (see Figure 2), but do indicate that it is by no means certain that a common factor is appropriate to all configurations. Of particular interest are those structures which offer a composite path where the discharge can take a variety of trajectories. To assess the ability of the design criteria to evaluate such configurations, cumulative stress analysis based on the computed electric field distribution was applied to Structure H (see Figure 3, right hand image, and the associated flux plot of Figure 5) for several composite paths with varying creep and bulk oil components, typified by the broken lines. The paths considered are represented in more detail in Figure 8 and include: (1) a 10 cm creep path between the disc electrodes, (2) a composite path consisting of the middle 6 cm of the creep surface and two 0.87 cm bulk oil paths departing perpendicularly from the creep surface to the ring electrodes, (3) a composite path consisting of the middle 3 cm of the creep surface and two 1.44 cm bulk oil paths departing at an angle from the creep surface to (c) Figure 7. Optical images of failure events. (a) dendritic outer surface creep, (b) bulk oil breakdown, (c) inner surface creep breakdown. Figure 8. Schematic (not to scale) representation of the failure paths considered for Structure H. [For description of numbered paths, see text].

482 J.K. Nelson and C. Shaw: The Design of Transformer Oil-Cellulose Structures the ring electrodes {such as the path shown in the flux plot of Figure 5}, (4) a composite path consisting of the middle 1 cm of the creep surface and two 2.25 cm bulk oil paths departing at an angle from the creep surface to the ring electrodes, and (5) a 4.6 cm bulk oil path between the ring electrodes. The analysis showed that the first path became critical when the potential difference between electrodes was 175 kv. The second path became critical at 172.5 kv and was limited by the creep component of the path. Likewise, the third path was creep-limited at 207.5 kv. The fourth path, however, was oillimited at 260 kv and the oil path became critical at 187.5 kv. The study suggests a minimum critical voltage for path (2). However, the photographic breakdown evidence favored the bulk oil path, path (4), with roughly 90% of the failures occurring along this path. There is evidence, however, of 10% creep failure as shown in Figure 6b giving rise to the mixed failure mode given in Table 3 for Structure H. Noting this, and the fact that the critical voltages of the two paths are only 10% different, it is plausible to conclude that the design criteria can be used to evaluate the integrity of composite paths with some measure of confidence. When comparing Structures A, G, H it should be noted that the creep curves used in these experiments assume paper covered electrodes [2], while the oil curve applied to G and H properly accounts for the fact that bare electrodes were used. In light of this, it is expected that the 1% ac breakdown value for Structure A, and for all creep structures, would be somewhat lower. As a result, the corresponding ratios would be higher. For example if the 1% ac values for the creep structures are lowered [2] by 15% to account for bare electrodes then the ratios for Structures A, B, and C become 2.58, 3.19, and 3.34, respectively. The results suggest that the structures with rings have similar factors as do the structures without rings excepting Structures E and D. The results also indicate that there is a substantial difference between the two values: roughly 2.5 for the structures with rings and 3.3 for the structures without rings. This suggests that certain structures are more susceptible to failure under steep front impulse conditions than are others. If the discussion in [9] is viewed in light of these results, it is conceivable that the failures occurred along susceptible paths. The factor of 2.5 for structures with rings is in-line with the factor used for lightning impulses. However, published results [8] show that the breakdown voltage for a 10 ns/2500 μs impulse is only 78-93% of the lightning impulse value depending on the insulating material tested. Some difference can thus be expected since the front time used in these experiments was 240 ns and the curve shown in Figure 2 may not continue increasing for smaller impulse front times. Comparison of Structure A (which is a creep configuration) with Structure H (which is the same structure with two oil gaps inserted to form a mixed path) would indicate that the provision of the series oil paths creates over a 40% improvement for impulse conditions, but less than 20% is predicted for ac with the attendant change in ratio from 2.19 (A) to 2.49 (H). The reasons for this probably lie in the small oil gap formed by the curvature of the ring where it meets the cylinder. This gap is readily discharged by the impulse voltage with the resulting precipitation of complete failure. Further evidence for this may be found in the comparison of Structures B and D which are again similar with the exception of the central disc barrier in Structure D designed to break up the creep path. While this barrier is seen to be effective for ac withstand, it is actually counter-productive for surge stresses yielding a very low ratio. This probably results again from initiating discharges in the inevitable interstitial oil gaps at the discontinuities shown arrowed in Figure 3. 5 CONCLUSION This limited study would suggest that the use of a universal equivalence between ac and impulse design criteria for oil/cellulose structures was not always appropriate. The nature of the structure will cause anomalies. However, the cumulative stress methodology used for ac would appear to provide some basis for the assessment of composite impulse breakdown paths despite the obvious physical differences. ACKNOWLEDGEMENTS The authors are grateful to the sponsors of the Philip Sporn Chair at Rensselaer for the support of this activity, and to EHV-Weidmann Industries for the fabrication of the numerous test samples involved. REFERENCES [1] J.K. Nelson, An assessment of the physical basis for the application of design criteria to dielectric structures, Trans. IEEE, Vol. 24, pp. 835-847, 1989. [2] H.P. Moser, Transformerboard, Scientia Electrica, 1979. [3] A. Tahani, J.K. Nelson and S.J. Salon, "Automated dielectric design of oil/cellulose structures - a computer implementation", Proc. 10th Conf. on the Computation of Electromagnetic Fields, Berlin, Germany, 1995. [4] W.R. Wilson, A fundamental factor controlling the unit dielectric strength of oil, Trans. AIEE, Vol.72, pp. 68-74, 1953. [5] E.J. Gumbel, Statistics of Extremes, Columbia Press, 1967. [6] P.B. McGrath and J.K. Nelson, Events leading to failure of transformer oil duct spacers, Conf. Elect. Ins. & Diel. Phen., NAS, pp. 249, 1976. [7] H. Hirose, More accurate breakdown voltage estimation for the new step-up test method in the Weibull model, IEEE Trans. Dielectr. Electr. Insul. Vol. 11, pp. 418-423, 2004. [8] E. Kreyszig, Ädvanced Engineering Mathematics, Wiley, 1983. [9] M. Vandermaar, M. Wang, J.B. Neilson and K.D. Srivastava, The Electrical breakdown characteristics of oil-paper insulation under steep front impulse voltages, IEEE Trans. Power Del., Vol. 9, pp. 1926-1933, 1994.

IEEE Transactions on Dielectrics and Electrical Insulation Vol. 13, No. 3; June 2006 483 J. Keith Nelson (F 90) was born in Oldham, UK and received his B.Sc.(Eng.) and Ph.D. degrees from the University of London, UK. He is currently Philip Sporn Chair of Electric Power Engineering at the Rensselaer Polytechnic Institute. Prior to his appointment at Rensselaer, he was manager of Electric Field Technology Programs at the General Electric R & D Center in Schenectady, NY. He has held numerous IEEE appointments including that of the Presidency of the Dielectrics & Electrical Insulation Society, 1995-6. He is a chartered electrical engineer, a Fellow of the IEE and the recipient of the IEEE Millennium Medal. Cory Shaw s interest in electricity started when he was working with his father as an electrician. He studied at the University of Utah and graduated with a Bachelors of Science in Electrical Engineering. He continued his studies at Rensselaer Polytechnic Institute where he completed his Masters in Electric Power Engineering. He currently works for Northeast Utilities as a Distribution Engineer.