Journal of Chemical and Pharmaceutical Research

Similar documents
Trace analysis of mesityl oxide and diacetone alcohol in pharmaceuticals by capillary gas chromatography with flame ionization detection

ISSN: ; CODEN ECJHAO E-Journal of Chemistry , 7(2),

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

Development and Validation of GC-FID Method for the Quantification of N-Iodosuccinimide

Impact factor: 3.958/ICV: 4.10 ISSN:

Volume 6, Issue 2, January February 2011; Article-015

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Development and validation a RP-HPLC method: Application for the quantitative determination of quetiapine fumarate from marketed bulk tablets

STABILITY INDICATING METHOD OF RELATED IMPURITIES IN VENLAFAXINE HYDROCHLORIDE SUSTAINED RELEASE TABLETS

2.1 2,3 Dichloro Benzoyl Cyanide (2,3 DCBC) and survey of. manufactured commonly for the bulk drug industry, few references were

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Int. J. Pharm. Sci. Rev. Res., 30(2), January February 2015; Article No. 09, Pages: 63-68

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Development of Validated Analytical Method of Mefenamic Acid in an Emulgel (Topical Formulation)

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

RP-HPLC Method Development and Validation of Dapagliflozin in Bulk and Tablet formulation

Journal of Chemical and Pharmaceutical Research, 2017, 9(10): Research Article

Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass Spectrometry

Research Article. UV Spectrophotometric Estimation of Alprazolam by second and third order derivative Methods in Bulk and Pharmaceutical Dosage Form

GC METHOD FOR QUANTITATIVE DETERMINATION OF RESIDUAL 2-(2-CHLOROETHOXY)ETHANOL (CEE) AND N-METHYL-2-PYRROLIDINONE (NMP) IN QUETIAPINE

International Journal of PharmTech Research CODEN (USA): IJPRIF, ISSN: , ISSN(Online): Vol.9, No.7, pp , 2016

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

DEVELOPMENT AND VALIDATION OF GC-FID METHOD FOR THE DETERMINATION OF ETHANOL RESIDUE IN MARJORAM OINTMENT

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

Research Article METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ELBASVIR AND GRAZOPREVIR BY RP-HPLC

A Simple, Novel Validated Stability Indicating RP-HPLC method for estimation of Duloxetine HCl in Capsule Pharmaceutical Formulation

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Method Development and Validation Of Prasugrel Tablets By RP- HPLC

Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article. Estimation of zaleplon by a new RP-HPLC method

Study of Residual Solvents in Various Matrices by Static Headspace

International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

Development and Validation of a Headspace Gas Chromatographic Method for determination of Residual Solvents in Bosentan Monohydrate.

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Validation of Stability-Indicating RP-HPLC Method for the Assay of Ibrutinib in Pharmaceutical Dosage form

Received: ; Accepted:

STABILITY INDICATING RP HPLC METHOD FOR ANALYSIS OF DORZOLAMIDE HCl IN THE BULK DRUG AND IT S PHARMACEUTICAL DOSAGE FORM

Sulfotepp impurities in Chlorpyrifos EC formulations

Method Development and Validation for the Estimation of Darunavir in Rat Plasma by RP-HPLC

DETERMINATION OF ORGANIC VOLATILE IMPURITIES IN NEPAFENAC BY GC METHOD

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

Research Article. Identification and characterization of unknown impurity in zolmitriptan tablets by a sensitive HPLC method

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

Development and Validation of Stability-Indicating RP-HPLC Method for Estimation of Atovaquone

STANDARD OPERATING PROCEDURES

Journal of Chemical and Pharmaceutical Research, 2017, 9(1): Research Article

Reverse Phase High Performance Liquid Chromatography method for determination of Lercanidipine hydrochloride in bulk and tablet dosage form

Zero And First Order Derivative Spectrophotometric Methods For Determination Of Dronedarone In Pharmaceutical Formulation

SIMPLE AND SENSITIVE VALIDATED REVERSE PHASE HPLC-UV METHOD FOR THE DETERMINATION OF LYMECYCLINE IN PHARMACEUTICAL DOSAGE FORMS

A Capillary Gas Chromatographic Procedure for the Analysis of Nine Common Residual Solvents in Water-Insoluble Bulk Pharmaceuticals

SIMULTANEOUS RP HPLC DETERMINATION OF CAMYLOFIN DIHYDROCHLORIDE AND PARACETAMOL IN PHARMACEUTICAL PREPARATIONS.

Journal of Chemical and Pharmaceutical Research

Stability-indicating HPLC determination of tolterodine tartrate in pharmaceutical dosage form

ASEAN GUIDELINES FOR VALIDATION OF ANALYTICAL PROCEDURES

Journal of Chemical and Pharmaceutical Research

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND LIFE SCIENCES

International Journal of Pharmaceutical Research & Analysis

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Development and validation of RP-HPLC method for the analysis of carbofuran and in its formulations

SIMULTANEOUS ESTIMATION OF MEFENAMIC ACID AND PARACETAMOL IN SUSPENSION FORM BY USING UPLC

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD TO DETERMINE CINITAPRIDE HYDROGEN TARTARATE IN BULK AND PHARMACEUTICAL FORMULATION

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

Appendix II- Bioanalytical Method Development and Validation

METHOD: 1403, Issue 3 EVALUATION: FULL Issue 1: 15 August 1990 Issue 3: 15 March 2003

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

CHAPTER - IV. Acharya Nagarjuna University, Guntur 105

Novus International Journal of Analytical Innovations 2012, Vol. 1, No. 3

Available online Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article

Development And Validation Of Rp-Hplc Method For Determination Of Velpatasvir In Bulk

Intercontinental journal of pharmaceutical Investigations and Research

Chapter 4: Verification of compendial methods

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

J Pharm Sci Bioscientific Res (4): ISSN NO

Pelagia Research Library

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

PA-DEP 3686, Rev. 1. Light Hydrocarbons in Aqueous Samples via Headspace and Gas Chromatography with Flame Ionization Detection (GC/FID)

Available online Research Article

Department of Post graduate Chemistry, SVRM College (Autonomous) Nagaram, Andhra Pradesh, India Corresponding Author:

Method for Characterization of Gum Rosin by Capillary Gas Chromatography

Stability indicating RP-HPLC method for determination of azilsartan medoxomil in bulk and its dosage form

Validated First Order Derivative Spectroscopic Method for the determination of Stavudine in Bulk and Pharmaceutical Dosage Forms

Analytical method development and validation of gabapentin in bulk and tablet dosage form by using UV spectroscopic method

DIQUAT DIBROMIDE. The Determination of Ethylene Dibromide in Diquat Dibromide and Diquat Dibromide / Paraquat Dichloride SL Formulations

International Journal of Pharma and Bio Sciences V1(1)2010. HPLC method for analysis of Lercanidipine Hydrochloride in Tablets

Research Article Available online at

Department of Chemistry, JNTUACE, Kalikiri

A Newly Approved ASTM Standard For Analysis of Thiophene in Benzene Using a Pulsed Flame Photometric Detector (PFPD)

DEVELOPMENT AND VALIDATION OF HPLC METHOD FOR THE ESTIMATION OF NICERGOLINE IN MARKETED FORMULATIONS

Dissolution study and method validation of alprazolam by high performance liquid chromatography method in pharmaceutical dosage form

INTERNATIONAL JOURNAL OF UNIVERSAL PHARMACY AND BIO SCIENCES

PHARMA SCIENCE MONITOR

Journal of Chemical and Pharmaceutical Research

A Generic Method for the Analysis of Residual Solvents in Pharmaceuticals Using Static Headspace-GC-FID/MS

RP-HPLC Method for the Determination of Cinitapride in the Presence of its Degradation Products in Bulk Drug

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Mashhour Ghanem 1 and Saleh Abu-Lafi 2 * ABSTRACT ARTICLE INFO

Transcription:

Available online www.jocpr.com Journal of Chemical and Pharmaceutical Research ISSN No: 0975-7384 CODEN(USA): JCPRC5 J. Chem. Pharm. Res., 2011, 3(6):392-399 Estimation of epichlorohydrin content in pharmaceutical drug substances by capillary gas chromatography with flame ionisation detection Shaik Jafer Vali * 1, Raveendra B.Ganduri 1 and Shakil S Sait 2 1 Department of Chemistry, J. N. T. University, Kukatpally, Hyderabad, A.P, India 2 Dr. Reddy's Laboratories Ltd. Active Pharmaceutical Ingredients, IPDO, Bachupally, Hyderabad, A.P, India ABSTRACT A rapid, economic, sensitive and reliable gas chromatographic method was developed and validated for the determination of residual Epichlorohydrin (ECH) in Pharmaceutical drug substances. This method utilized a Alltech AT-WAX GC column stationary phase consists of 100% polyethylene glycol, helium as carrier gas with flame ionization detection. The critical experimental parameters, such as, Column selection, injection volume and diluent were studied and optimized. The method was validated as per United States Pharmacopoeia (USP) and International Conference on Harmonization (ICH) guidelines in terms of detection limit (DL), quantitation limit (QL), linearity, precision, accuracy, ruggedness and robustness. A linear range from 0.6 to 3.4 µg/ml was obtained with the coefficient of determination (r2) 0.9985. The DL and QL of ECH were 0.15 µg/ml and 0.6 µg/ml, respectively. The recovery obtained for ECH was between 96.8% and 97.4%. This method was applied successfully to determine the content of Epichlorohydrin in several Pharmaceutical drug substances. Keywords: Pharmaceutical drug substances, Carcinogen, Epichlorohydrin, Dimethyl sulphoxide, Validation, FID and GC. INTRODUCTION Epichlorohydrin is a versatile precursor in the synthesis of many organic compounds. Epichlorohydrin (ECH) is irritating and moderately toxic as well as carcinogenic, Toxic by inhalation, in contact with skin and if swallowed. ECH is chemically chloromethyloxirane. Epichlorohydrin (1-chloro-2,3-epoxypropane) is used mainly for the manufacture of pharmaceutical products, glycerol, unmodified epoxy resins and, to a lesser extent, elastomers, water-treatment resins, surfactants, ion exchange resins, plasticizers, dyestuffs, oil emulsifiers, lubricants, and adhesives [1]. Epichlorohydrin is mutagenic in most short-term assays and the 392

maximum contaminant level goal for Epichlorohydrin has been set at zero by the US Environmental Protection Agency (EPA). A review about the mutagenic and clastogenic effects of Epichlorohydrin is available [2]. Due to its toxicity, Epichlorohydrin has been listed among compounds dangerous to the water environment. No acceptable means of detecting Epichlorohydrin are currently available and the EPA requires water suppliers to use special treatment techniques to control its release into the environment [3-7]. The manufacturing process of bulk drugs consists of chemical synthesis extending to seven eight stages of processing involving different type of chemical reactions. In any one of the stage during synthesis of drugs if Epichlorohydrin is used or present by directly or indirectly determine the content of Epichlorohydrin using the above method. Fig 1. Epichlorohydrin Chemical Structure EXPERIMENTAL SECTION Chemicals and reagents Spectroscopy grade dimethyl sulfoxide (DMSO), N,N-dimethyl formamide (DMF) and 1- methyl-2-pyrrolidone (NMP) were procured from Merck (Mumbai, India). Analytical grade N,N-dimethyl acetamide (DMAc) was from s.d Fine Chem. Ltd (Mumbai, India). (±) Epichlorohydrin (99+%) was purchased from Sigma-Aldrich. API drug substances are obtained from Pharma industries of Hyderabad, India. Instrumentation An Agilent 6890 GC (Agilent, Palo Alto, CA, USA) equipped with an auto sampler was used in the experiment; a straight glass injection liner with glass wool was obtained from Restek, (Restek and Bellefont, PA, USA). Data acquisition and processing were conducted using the waters Empower software. Preparation of Stock, Standard and Test Solutions The stock solutions of Epichlorohydrin were prepared by dissolving 30mg of Epichlorohydrin in 10mL solvent (stock-1). The 1000 µg ml -1 solution was prepared by transferring 1mL of the stock-1 solution into a 10mL volumetric flask and diluting to volume with sample solvent (stock- 2), and further diluted to 75µL of the stock-2 solution into a 10mL volumetric flask and diluting to volume with sample solvent (7.5 ppm standard solution). 200µL of the stock-2 solution transferred into a 100mL volumetric flask and diluting to volume with sample solvent (LOQ solution) and 2.5mL of LOQ solution transferred into a 10mL volumetric flask and diluting to volume with diluent (LOD solution). The sample solution was prepared by accurately weighing about 1500 mg of the drug substance into a 5mL volumetric flask and dissolving in 5 ml of sample solvent. If sample solution becomes hazy filter the solution through 0.45µ nylon filter and collect clear solution in GC vials. Chromatographic Conditions The GC separation was conducted on an Alltech AT-WAX column with a dimension of 30 meter, 0.53 mm and a film thickness of 1.0 µm. Helium was used as carrier gas at a constant pressure of 4 psi. The GC oven temperature program utilized an initial temperature of 75 C and 393

an initial holding time of 12 min, and then increased at 40 C per minute to 240 C. The final temperature was held for 10 minutes. A flame ionization detection (FID) system was used. The detector temperature was set at 260 C. The samples were injected with the Agilent 6890 series auto sampler. The inlet temperature was kept at 160 C. The samples were injected in a split (1:0.5) mode with a 1.0 µl injection volume unless otherwise specified. RESULTS AND DISCUSSION Method Development and Optimization The main challenge was to achieve the desired detection and quantitation limit using the most commonly available instrument, i.e. a gas chromatograph with a FID system. To obtain the desired sensitivity, one approach is to increase sample amount injected into the GC system. The adoption of a megabore capillary GC column (0.53 mm I.D.) with a high capacity bonded stationary phase seems to be the obvious choice. Suitable initial column temperature in combination with a moderate inlet temperature (160 C) may allow a relatively large injection volume without significant deterioration in column efficiency. The effect of injection volume on the quantitation of the Epichlorohydrin was investigated by injecting between 0.5 µl and 2 µl of the standard solution containing 2 ppm each of Epichlorohydrin [Fig.4-6]. The results show that the peak widths of Epichlorohydrin are independent of injection volume within the tested range. Further studies were done to select the suitable column which can retain the Epichlorohydrin at a suitable retention time (RT) and the suitable diluent which should not interfere at any unknown peak at Epichlorohydrin RT place. Based on certain trials AT-WAX column was chosen and Dimethyl sulphoxide diluent was most desirable which is not having any interference at Epichlorohydrin RT place [Fig.3]. Comparison of LOQ solution with blank was shown in Fig.7. This method utilizes a dissolve-and-inject approach for the analysis. Several factors were considered in selection of a sample diluent, including the purity, its ability to dissolve the analyte, and its chemical compatibility with the compounds of interest. To detect the Epichlorohydrin at 0.50ppm level, the purity of sample solvent is critical. It has been observed in our laboratory that the Chromatography grade solvents are generally suitable. Fig.2: A typical chromatogram of Blank (dimethyl sulfoxide [DMSO]) 394

Fig.3: A typical chromatogram of Epichlorohydrin from 7.5 ppm standard solution Fig.4: A typical chromatogram of Epichlorohydrin from LOD Solution Fig.5: A typical chromatogram of Epichlorohydrin from LOQ Solution 395

40.00 38.00 36.00 34.00 32.00 pa 30.00 28.00 26.00 24.00 Epichlorohydrin - 8.885 22.00 20.00 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 26.00 Minutes Fig.6: A typical chromatogram of Epichlorohydrin Comparison of LOQ Solution with blank Method Validation The validation work was conducted according to the ICH (International Conference on Harmonization) guidelines [8-9] the validated method parameters include accuracy, precision, linearity, ruggedness and robustness. The detection limit (LOD) of the method for the Epichlorohydrin was estimated from a chromatogram of a solution containing about 0.50ppm. From the chromatogram, a signal-tonoise ratio of 2.7 was obtained. In the pharmaceutical industry, the quantitation limit (LOQ) was defined as the lowest amount of analyte in a sample that can be quantitatively determined with suitable precision and accuracy. The LOQ was determined to be 2.0ppm for Epichlorohydrin. From the chromatogram, a signal-to-noise ratio of 10.0 was obtained for LOQ solution. Precision and accuracy data for LOQ solution discussed below. The experimental results also showed that this method has excellent precision without using an internal standard. Multiple injections (n=6) were made for the standard solutions containing 2.0ppm of Epichlorohydrin. For six injections of the solution, the RSD of the peak area of Epichlorohydrin was found to be 2.6% (Table 1). Accuracy of the method was determined by analyzing drug substance samples spiked with limit of quantification amount of the Epichlorohydrin. The recovery was 91.1% for Epichlorohydrin. Linearity of the method was determined by preparing and analyzing a series of six (n=6) standard solutions to cover the concentration range of 2ppm 11.25ppm (LOQ to 150%).The coefficient of determination (R 2 ) obtained for ECH was 0.9985 (Fig.8). Accuracy of the method was determined by analyzing drug substance samples (n=3) spiked with 3.75ppm, 7.5ppm and 11.25ppm of the Epichlorohydrin. The recovery was 96.9%, 97.2% and 97.4% respectively for Epichlorohydrin (Table 2). Ruggedness of the method was performed by doing precision study for the standard solution with different column, different system and different analyst and the percentage RSD for the Epichlorohydrin peak area is about 4.7. Robustness of the method was checked by varying the column oven temperature from 75 C to 70 C and 80 C and the column flow from 4 psi to 3.8 psi and 4.2 psi. Precision study was done 396

in the above modified conditions for the standard solution and the percentage RSD for the Epichlorohydrin peak area was tabulated below (Table 3). Solution study was performed for 24 hours and found the solution to be stable. The selectivity of the method also demonstrated by injecting the process related solvents which are used for preparing API drug and those are well separated with Epichlorohydrin. This method can be used for all API drugs. If any of the API drug process related solvent interfering at the RT of Epichlorohydrin RT then slightly modify the flow of the carrier gas so that it can separate with the Epichlorohydrin peak. Table 1: Precision at LOQ Preparation No Retention time Epichlorohydrine (Area) 01 8.811 5.10 02 8.802 5.01 03 8.805 5.19 04 8.808 4.98 05 8.805 4.91 06 8.812 4.82 Average 8.807 5.00 Standard deviation 0.004 0.13 %RSD 0.04 2.64 Table 2: Accuracy Results Level of Accuracy S.No. ECH added (µg/ml) ECH recovered (µg/ml) % ECH Mean ± SEM (n=3) 1 0.302 0.293 at 50% 2 0.313 0.301 96.86 ± 0.26 3 0.307 0.299 1 0.750 0.731 at 100% 2 0.756 0.735 97.21 ± 0.10 3 0.755 0.732 at 150% 1 1.520 1.480 2 1.510 1.470 3 1.530 1.490 97.36 ± 0.02 397

Fig.7: Linearity curve Preparation No Oven temperature (70 C) Epichlorohydrin Table 3: Robustness Data Precision at different conditions Oven temperature (80 C) Carrier gas flow (3.8 psi) Carrier gas flow (4.2 psi) Epichlorohydrin Epichlorohydrin Epichlorohydrin Area RT Area RT Area RT Area RT 01 13.22 10.349 13.67 7.657 13.30 9.827 13.71 8.022 02 13.20 10.347 14.11 7.673 13.00 9.816 14.11 8.027 03 13.52 10.350 13.85 7.658 12.08 9.830 13.93 8.029 04 13.44 10.347 14.02 7.662 13.39 9.828 13.65 8.029 05 13.19 10.323 13.76 7.671 12.89 9.835 13.79 8.029 06 13.53 10.336 14.19 7.660 13.24 9.824 14.00 8.034 Average 13.35 10.342 13.93 7.664 12.98 9.827 13.87 8.028 Standard deviation 0.16 0.01 0.21 0.01 0.48 0.01 0.18 0.004 %RSD 1.23 0.102 1.47 0.089 3.70 0.065 1.28 0.048 CONCLUSION A simple and sensitive GC method has been developed and validated for the trace level analysis of Epichlorohydrin in Milnacipran hydrochloride. Compared with the previously reported methodologies, this method utilizes a FID detector, which is readily available in most of the quality control testing laboratories in the pharmaceutical industry and relatively simple to use. This method is sensitive enough to detect 0.50ppm of Epichlorohydrin and can quantify up to 2.0ppm. It is having less run time and avoided headspace and splitlless techniques which create lot of interference and baseline noise. REFERENCES [1] 1. World Health Organization, Chemical review: epichlorohydrin, in: Dangerous Properties of Industrial Materials Report, vol. 12(2), 1992, 150 170. [2] AK Giri - Mutation Research/Reviews in Mutation Research, 1997 - Elsevier [3] United States Environmental Protection Agency, Office of Water, Fact Sheet, last revised 26 Jan 1998, Internet URL address: www.epa.gov/ogwdw/dwh/c-voc/epichlor.html. 398

[4] Epichlorohydrin, Geneva, World Health Organization, 1984 (Environmental health Criteria, No.33). [5] World Health Organization, Chemical review: epichlorohydrin, in: Dangerous Properties of Industrial Materials Report, vol. 12(2), 1992, 150 170. [6] World Health Organization (WHO). http://www.who.int/docstore/water_sanitation_health/gdwq/draftchemicals/epichlorohydrin20 03.pdf. [7] L. Michael, C. Larry and E. Pellizzari. Environ. Sci. Technol. 5 (1988), p. 565. doi:10.1021/es00170a014. [8] ICH Guide Q2A: Text on Validation of Analytical Procedures: Term and definition, [9] International Conference on harmonization, Fed. Reg. (60 FR 11260), 1 March 1995 [10] ICH Guide Q2B: Validation of Analytical Procedures: Methodology, International Conference on harmonization. Fed. Reg. (62 FR 2463), 19 May 1997 399