Temperature Dependence Calibration and Correction of the DAMPE BGO Electromagnetic Calorimeter

Similar documents
Dark Matter Particle Explorer: The First Chinese Cosmic Ray and Hard γ-ray Detector in Space

PoS(ICRC2017)168. PSD performance and charge reconstruction with DAMPE

PoS(ICRC2017)775. The performance of DAMPE for γ-ray detection

Dark Matter Particle Explorer and Its First Results

PoS(ICRC2017)1076. Studies of Cosmic-Ray Proton Flux with the DAMPE Experiment

Measurement of absolute energy scale of ECAL of DAMPE with geomagnetic rigidity cutoff

Cosmic Rays and the need for heavy payloads

arxiv: v1 [physics.ins-det] 8 Dec 2017

The Silicon-Tungsten Tracker of the DAMPE Mission

The NUCLEON Space Experiment Preliminary Results. Skobeltsyn Institute of Nuclear Physics, Moscow State University, Moscow, , Russia

Studies of Hadron Calorimeter

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER

DAMPE Operations at Chinese Space Science Mission Center

Cosmic Rays at 120,000 feet above Antarctica The Advanced Thin Ionization Calorimeter (ATIC) Experiment

THE ELECTROMAGNETIC CALORIMETER OF THE AMS-02 EXPERIMENT

An algorithm to resolve γ-rays from charged cosmic rays with DAMPE

Preliminary results from gamma-ray observations with the CALorimeteric Electron Telescope (CALET)

First Stage Analysis of the Energy Response and Resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

THE AMS RICH COUNTER

Chapter 6.2: space based cosmic ray experiments. A. Zech, Instrumentation in High Energy Astrophysics

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

Measurements of Heavy Nuclei with the CALET Experiment

Radioactivity and Ionizing Radiation

Lomonosov Moscow State University. NUCLEON Chemical Composition and Energy Spectra of Cosmic Rays at TeV

A method to measure transit time spread of photomultiplier tubes with Cherenkov light

Construction and Test of the Top and Bottom Counting Detectors for the ISS-CREAM Experiment

Preliminary Results From The First Flight of Atic: The Silicon Matrix

Cosmic Ray Physics with the Alpha Magnetic Spectrometer

Timing calibration of the LHAASO-KM2A electromagnetic particle detectors

Development of a homogeneous, isotropic and high dynamic range calorimeter for the study of primary cosmic rays in space experiments

The EDM Polarimeter Development at COSY-Jülich

The Fermi Gamma-ray Space Telescope

Dual readout with tiles for calorimetry.

Justin Vandenbroucke (KIPAC, Stanford / SLAC) for the Fermi LAT collaboration

High Energy cosmic-radiation Detection (HERD) Facility onboard China s Space Station

The space mission PAMELA

A machine learning method to separate cosmic ray electrons from protons from 10 to 100 GeV using DAMPE data

9/27 JUNE 2003 SUMMER STAGE PARTICLES REVELATION THROUGH CERENKOV AND SCINTILLATION COUNTER AND THE CEBAF EXPERIMENT

CALICE Si-W EM Calorimeter: Preliminary Results of the Testbeams 2006

Development of a 3D-Imaging Calorimeter in LaBr 3 for Gamma-Ray Space Astronomy

The High Energy cosmic-radiation Detection (HERD) Facility onboard China s Future Space Station

The Advanced Thin Ionization Calorimeter (ATIC) Long Duration Balloon Experiment

A NEW GENERATION OF GAMMA-RAY TELESCOPE

ATLAS Hadronic Calorimeters 101

Radiation (Particle) Detection and Measurement

Lecture 2 & 3. Particles going through matter. Collider Detectors. PDG chapter 27 Kleinknecht chapters: PDG chapter 28 Kleinknecht chapters:

David Gascón. Daniel Peralta. Universitat de Barcelona, ECM department. E Diagonal 647 (Barcelona) IFAE, Universitat Aut onoma de Barcelona

Primary cosmic ray mass composition above 1 PeV as measured by the PRISMA-YBJ array

Dark Matter Searches with AMS-02. AMS: Alpha Magnetic Spectrometer

High-energy Gamma Rays detection with the AMS-02 electromagnetic calorimeter. F. Pilo for the AMS-02 ECAL Group INFN Sezione di Pisa, Italy

Publications of Francesco Arneodo: journal articles

Correction for PMT temperature dependence of the LHCf calorimeters

arxiv: v1 [physics.ins-det] 27 Jun 2017

Current and Future balloon and space experiments L. Derome (LPSC Grenoble) Tango, May 4-6th, 2009

CALET INSTRUMENT. Calorimeter CGBM

Galactic cosmic rays from NUCLEON to HERO. (in Moscow State University) Lomonosov Moscow State University

Calorimetry in. in Nuclear and Particle Physics Experiments

PoS(ICRC2015)432. Simulation Study On High Energy Electron and Gamma-ray Detection With the Newly Upgraded Tibet ASgamma Experiment

Measuring the Deposited Energy by the Scintillation Calorimeter in the ATIC Experiment

Bright gamma-ray sources observed by DArk Matter Particle Explorer

THE main physics motivation for building the Compact

CALICE Test Beam Data and Hadronic Shower Models

The Large Area Telescope on-board of the Fermi Gamma-Ray Space Telescope Mission

Commissioning of the ATLAS LAr Calorimeter

First Stage Analysis of the Energy response and resolution of the Scintillator ECAL in the Beam Test at FNAL, 2008

Indirect Dark Matter Detection

Les Premières Données dans ATLAS et le Calorimètre à Argon Liquide

Very High Energy Gamma Ray Astronomy and Cosmic Ray Physics with ARGO-YBJ

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

Last Lecture 1) Silicon tracking detectors 2) Reconstructing track momenta

Scintillation Detectors

X- & γ-ray Instrumentation

Scintillation Detectors

Experimental review of high-energy e e + and p p spectra

Neutron pulse height analysis (R405n)

Gamma rays, electrons and positrons up to 3 TeV with the Fermi Gamma-ray Space Telescope

Validation of Geant4 Physics Models Using Collision Data from the LHC

MoonCal An electromagnetic calorimeter on the lunar surface. R.Battiston, M.T.Brunetti, F. Cervelli, C.Fidani, F.Pilo

7th International Conference on New Developments In Photodetection

PoS(ICRC2015)430. Shower reconstruction performance of the new Tibet hybrid experiment consisting of YAC-II, Tibet-III and MD arrays

Calorimeter for detection of the high-energy photons

The CALorimetric Electron Telescope (CALET): High Energy Astroparticle Physics Observatory on the International Space Station

Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics. PAMELA MissioN 17 December 2010 Prepared by FatiH KAYA

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

arxiv: v1 [astro-ph.im] 18 Jul 2014

Neutral particles energy spectra for 900 GeV and 7 TeV p-p collisions, measured by the LHCf experiment

CMS ECAL status and performance with the first LHC collisions

arxiv:physics/ v1 3 Aug 2006

PAMELA: a Satellite Experiment for Antiparticles Measurement in Cosmic Rays

Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

Gamma Ray Physics in the Fermi era. F.Longo University of Trieste and INFN

Status of the PAMELA silicon tracker

Particle Energy Loss in Matter

PHY492: Nuclear & Particle Physics. Lecture 25. Particle Detectors

Test bench for measurements of NOvA scintillator properties at JINR D.S. Velikanova, 1 A.I. Antoshkin, 1 N.V. Anfimov, 1 O.B.

Survey of the performance of scintillation materials at low temperatures

Electronic calibration of the ATLAS LAr calorimeter and commissioning with cosmic muon signals

N U C L E O N. Satellite Mission. Present status.

SUPPLEMENTARY INFORMATION

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

Transcription:

Temperature Dependence Calibration and Correction of the DAMPE BGO Electromagnetic Calorimeter Yifeng Wei, Zhiyong Zhang, Yunlong Zhang*, Sicheng Wen, Chi Wang, Zhiying Li, Changqing Feng, Xiaolian Wang, Zizong Xu, Guangshun Huang*, Shubin Liu State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui, China, 230026 Department of Modern Physics, University of Science and Technology of China, Hefei, Anhui, China, 230026 Abstract A BGO electromagnetic calorimeter is built for DArk Matter Particle Explorer(DAMPE) mission. The temperature effect of BGO ECAL has been investigated with a thermal vacuum experiment. The light output of BGO crystal depends on temperature significantly. Temperature coefficient of each BGO crystal bar has been calibrated, and a correction method is also presented in this paper. Keywords: DAMPE, BGO electromagnetic calorimeter, temperature effect 1. Introduction The DArk Matter Particle Explorer project is a Chinese space detection mission for precise measurement of high energy electron, gamma ray and nuclei from deep space. It has been launched in the end of 2015. So far, the physical origin of unexpected galactic electron/positron excesses [1][2][3] is still to be figured out. DAMPE will provide a high energy resolution measurement of (e + +e - ) spectrum from 5 GeV to 10 TeV, which has not been revealed by existing experiments in 1 TeV to 10 TeV ranges. DAMPE can also measure protons, helium nuclei and other cosmic ions in the energy band from 10 GeV to ~ 1 PeV [4]. The DAMPE detector consists of four sub-detectors (Fig. 1). The plastic scintillator detector(psd) is used to identify electron, photon and cosmic ions; the silicon tungsten tracker(stk) provides tracking; and the neutron detector(nud) is designed to improve the electron/proton separating capability for proton background rejection in space. The emphasis of this paper is the BGO electromagnetic calorimeter (BGO ECAL), which provides a high precision measurement of energy. The DAMPE satellite orbits the earth at the altitude of 500 km, and the designed maximum temperature variation of the BGO ECAL ranges from -15 o C to +20 o C under the satellite thermal control system. The ECAL is made up of 308 BGO crystal bars, each with dimensions of 25 25 600 mm 3. Like most of inorganic crystals, the scintillation light yield of BGO crystal depends on the temperature. The reference value of temperature dependence of BGO crystal is -0.9%/ o C [5], and the PMTs produced by Hamamatsu also depend on temperature (~ -0.4%/ o C) [6]. We have investigated the temperature dependence of a single BGO crystal bar coupled with a PMT [7]. In order to well understand the temperature performance of the full calorimeter, a thermal vacuum experiment of DAMPE flight model has been performed in July, 2015.

Fig. 1 Structure of DAMPE detector 2. Design of BGO Calorimeter The BGO ECAL is to measure energy deposition of particles with a wide range, from 5 GeV to 10 TeV, and with a good energy resolution of 1.5% at 800 GeV for photons and electrons. The ECAL contains 14 layers (~ 31 radiation lengths), and 22 BGO crystal bars in each layer. The layers of BGO crystal bars are alternated in an orthogonal way to measure the deposited energy and profile of hadron and electromagnetic showers developed in the BGO ECAL (Fig. 2). Scintillation light is detected at both ends of a BGO crystal bar with two PMTs, respectively. An asymmetry design is applied in the readout of two PMTs. The signal of high gain output (called Side 0) is about five times as large as the low gain (Side 1). The required range of energy response for one BGO detector unit (BGO crystal bar + PMT) is from 10 MeV to 2 TeV. To obtain such a wide dynamic range, a multi-dynode readout circuit of PMT base is used, and dynode 2, 5, 8 of PMT correspond to low, middle and high gain, respectively [8][9]. Fig. 2 BGO crystal bars arrangement in the ECAL 3. Thermal vacuum experiment The primary goal of thermal vacuum (TV) environmental experiment was to validate the thermal performance of the DAMPE flight model. For the BGO sub-detector, the cosmic ray data in the period of TV experiment was utilized to study temperature dependence. The DAMPE detector was held in a cylinder chamber, and covered by a heating cage (Fig. 3). A liquid nitrogen cooling layer was around the instrument

inside the chamber. There was a thermally insulating layer between the DAMPE detector and the support platform. Fig. 4 shows the temperature variation measured by a thermistor attached on the surface of a BGO crystal bar, and the precision of this kind of thermistor is 0.1 o C. There are one long cycle (July 2 nd ~ July 10 th ) and four short cycles (July 10 th ~ July 16 th ) during the TV experiment. The change rate of temperature in the large cycle, which was no more than 1 o C/hour, was much gentler than the rate in the short cycle, and therefore, temperature dependence was calibrated with the data of the long cycle. Since two high voltage working modes (800V and 1000V) are applied on orbit (800V is normal mode), the experiment was carried on these two modes, respectively. The periods of different high voltage modes are marked in Fig. 4. Fig. 3 Thermal vacuum experiment setup Fig. 4 Temperature curve of one BGO crystal bar

4. Temperature dependence calibration The cosmic ray muon in the long cycle was used for temperature calibration. The energy deposit from a muon minimum ionizing particle (MIP) passing through a 2.5 cm thick BGO bar is about 22.5 MeV. Fig. 5 shows the energy deposition spectra of muon MIPs at different temperatures. These spectra were fitted with Landau convoluted with Gaussian, and the Landau MPV values could represent the light output of BGO crystal bars. For an individual detector unit (BGO crystal bar + PMT), the MPV value decreases with the increase of temperature (Fig. 6), whose variation trend can be described well by a linear function in this temperature range. The temperature coefficient is defined as: C " = $%&'( &* *+" %+,( -,"(./('" &* *+" %+,( This coefficient is exactly the temperature dependence at 0 o C. Fig. 7 shows the distribution of C t values from the 308 BGO detector units, with a mean value of -1.322%/ o C, which includes the contribution of BGO crystal as well as that of readout electronics (PMT, base board and FEE). In comparison, the temperature coefficient measured by ATIC experiment is -1.86%/ o C [10]. (1) Fig. 5 Cosmic ray muon spectra at different temperatures

Fig. 6 The variation of MIPs MPV values with temperature Fig. 7 Temperature coefficient distribution of 308 BGO crystal unit 5. Temperature effect correction After calibrating the temperature coefficient of each BGO crystal unit, another point should be made clear. Only dynode 8 (high gain) can produce a significant signal when a muon MIP deposits its energy in a BGO crystal bar, because the ADC counts of dynode 2 and 5 are too small to be separated from pedestal noise, and this means, the coefficient calibrated with muon MIPs can only represent the temperature dependence of dynode 8. Therefore, the temperature dependence of dynode ratio of dy8 ADC to dy5 ADC has been investigated, which was calibrated by rare shower events of cosmic ray muon. Fig. 8 gives the change of dynode 8/dynode 5 ratio with time. It is clear that the dynode 8/dynode 5 ratio has no obvious temperature dependence, and the plateau is just because the high voltage was switched to 1000V mode during July.7 to July.10. Thus, the temperature coefficient calibrated with muon MIPs for dy8 could be used for other dynodes of the same PMT. In correction algorithm, the following function is applied: ADC 2&. = 342 567 2 8 :;< (2) Where ADC raw is raw ADC output of front electronics, ADC Cor is the value after temperature correction, T is the temperature and C t is the temperature coefficient. This correction was applied to each output of the three PMT dynodes to compensate for temperature variation event by event, and the ADC counts of all channels were normalized to 0 o C. The cosmic ray in the period of four short thermal cycles (in Fig. 4) is utilized for validation of temperature correction. Fig. 9 shows that the raw MPV values (triangle points) increase synchronously with the temperature decrease and after correction, the MPV values (circle points) approach to a constant at reference temperature (at 0 o C). To evaluate the correction, the uniformity of MPV value is defined as: Uniformity = FG$ HIJ G(K, HIJ (3) Where RMS and Mean are statistical parameters of MIPs MPV values measured in different temperature.

The MPV uniformities of 308 BGO crystal units are shown in Fig. 10, which are improved from about 9% to about 2% after correction. Fig. 8 Dynode 5/8 ratio with time

Fig. 9 Comparison of muon MIPs MPV value before and after correction Fig. 10 Comparison of MPV uniformity before and after correction.

6. Conclusion The temperature performance of DAMPE flight model BGO calorimeter has been studied in a thermal vacuum experiment. The mean value of temperature coefficients for the 308 units has been measured to be -1.322%. An algorithm has also been developed to correct the temperature effect, which improves the MPV uniformity to about 2%. Acknowledgments This work was supported by the Chinese 973 Program, Grant No. 2010CB833002, the Strategic Priority Research Program on Space Science of the Chinese Academy of Science, Grant No. XDA04040202-4 and 100 Talents Program of CAS. The author would like to thank to the colleagues in DAMPE collaboration, NUAA (Nanjing University of Aeronautics and Astronautics) and SECM (Shanghai Engineering Center for Microsatellites) for their contributions to the thermal vacuum experiment. References [1] O. Adriani, G. Barbarino, G. Bazilevskaya et al, Physical Review Letters, 113(12): 121102 (2014). [2] Abdo A A, Ackermann M, Ajello M et al, Physical Review Letters, 102(18): 181101 (2009). [3] Adriani O, Barbarino G C, Bazilevskaya G A et al, Physical Review Letters, 106(20): 201101 (2011). [4] J. Chang, Chinese Journal of Space Science, 34(5): 550-557 (2014) [5] Olive K A, Particle Data Group, Chinese Physics C, 38(9): 090001 (2014). [6] Photomultiplier tubes and related products (Hamamatsu): http://www.hamamatsu.com/resources/ pdf/etd/pmt_tpmz0001e.pdf [7] P.L. Wang, Y.L. Zhang, Z.Z. Xu et al, Science China Physics, Mechanics & Astronomy, 57(10): 1898-1901 (2014). [8] Z.Y. Zhang, Y.L. Zhang, J.N. Dong et al. Nuclear Instruments and Methods in Physics Research Section A, 780: 21-26 (2015). [9] Y.L. Zhang, B. Li, C.Q. Feng et al, Chinese Physics C, 36(1): 71-73 (2012). [10] Isbert J, Adams J H, Ahn H S, et al. Advances in Space Research, 42(3): 437-441 (2008).