CEO LETTER. - Rolf Ludwig

Similar documents
PROPULSION LAB MANUAL

Welcome. Founded in 1899 by. University of Illinois. Professor S.W. Parr, Parr. Instrument Company has. consistently strived to

Measuring Energy Changes. Introducing Heat Capacity and Specific Heat

Welcome. Founded more. than 100 years ago by. University of Illinois. Professor S.W. Parr, Parr. Instrument Company has. consistently strived to

Wind Speed & Direction Sensors

MEEN 3242 MEE LAB II

SKALAR. your partner in chemistry automation. Primacs SN Protein-Nitrogen Analyzer

Basic Analytical Techniques, Calorimeter, and Conductivity Meter

Thermochemistry: Calorimetry and Hess s Law

Instruction Manual HI Refractometer for Invert Sugar Measurements

Applied Nuclear Science Educational, Training & Simulation Systems

Multi-element process analyzer

SLH-K Handheld Ultrasonic Flowmeter

Temperature Sensor -40 C to 140 C

A new chapter. medicacorp.com

IMPROVED ADIABATIC CALORIMETRY IN THE PHI-TEC APPARATUS USING AUTOMATED ON-LINE HEAT LOSS COMPENSATION

Experiment 14 It s Snow Big Deal

Welcome. Mike Steffenson President. Founded more than. 100 years ago by. University of Illinois. Professor S.W. Parr, Parr Instrument.

Baltimore Aircoil Company w w w. B a l t i m o r e A i r c o i l. c o m

EVEN THE FINEST CANNOT ESCAPE. Wöhler SM 500 Suspended Particulate Analyser

All-in-one or BOX industrial PC for autonomous or distributed applications

CHIP-TYPE EDLC Surface Mount Type Product Catalog

473 Dew Point Hygrometer

Compact ph Measuring Instruments With Pro Engineering

SmartDairy Catalog HerdMetrix Herd Management Software

Hess' Law: Calorimetry

SKALAR. your partner in chemistry automation. Primacs SNC Total Carbon and Total Nitrogen Analyzer

Mobile coulometer for water determination anywhere you want

WeatherHub2 Quick Start Guide

4 BOMB CALORIMETRY. Chapter 4. Bomb Calorimetry 24 I. PREPARATION

New Gen eration Calorimeters

COMBUSTION OF FUEL 12:57:42

R-Biopharm AG RIDA CUBE SCAN. The smart analyser. Product Information. R-Biopharm for the safety of your analysis.

473-SHX Dew Point Mirror

AC : PC-BASED MEASUREMENT OF THE HEAT OF COMBUSTION OF A SOLID FUEL USING OXYGEN BOMB CALORIMETER

Thermal Analysis Premium

RheolabQC. Rotational Rheometer for Quality Control. ::: Intelligence in Rheometry

483M. Introduction to Bomb Calorimetry

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

Edgetech Instruments Inc.

Petrochemical. Transformer Oil Gas Analysis - TOGA

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

One-hand ph/temperature measuring instrument

Analytical Instruments

Instruction Manual HI Refractometer for Sucrose in Wine and Grape Products Measurements

COMBI has been developed to be easily integrated in all types of laboratories and hospitals for routine, emergency as well as specific analysis.

Analyzing & Testing. Photocalorimetry Photo-DSC. Method, Technique, Applications. Photo-DSC 204 F1. Leading Thermal Analysis

473 Dew Point Hygrometer

Lab Activity H4 It s Snow Big Deal

LANCOM200 PORTABLE ACID DEWPOINT TEMPERATURE MONITORING. Acid Dewpoint SO3 H2 SO4 QUALITY CUSTOMER SOLUTIONS

An Introduction to Insulation Resistance Testing

Perseverance. Experimentation. Knowledge.

NEW! PCR next to me. Eppendorf Mastercycler nexus: combine, connect, control

Bomb Calorimetry: Heat of Combustion of Naphthalene

CHEM Thermodynamics. Work. There are two ways to change the internal energy of a system:

Meteorological Instruments for Solar Energy

Applied Nuclear Science Educational, Training & Simulation Systems

ISO 1928 INTERNATIONAL STANDARD

testo 205, 206, 230 Compact ph Measuring Instruments With Pro Engineering With interchangeable measurement electrode Draft Version

PTS Volt DC surface mount resettable PTC devices. Technical Data Applications. Agency information.

Measurement & Analytics Measurement made easy. MB3600-CH70 FT-NIR polyol analyzer Pre-calibrated for OH value determination

ABX Pentra 400. Clinical Chemistry System. Up to 420 tests/hour 55 Assays Validation Station

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

An industrial radiography exposure device based on measurement of transmitted gamma-ray intensity

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

CyFlow Ploidy Analyser & CyFlow Space High-resolution DNA analysis

Instruction Manual HI Refractometer for Sodium Chloride Measurements

MAGMA NOTE! 21+ USER MANUAL

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

STUD & TRACK ROLL FORMING MACHINE

Air velocity & IAQ measuring instruments

HANDHELD GAS ANALYZER DELTA 65

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

Schmetz_Fakten_gb_2007.qxd:Schmetz_Fakten_gb_ :37 Uhr Seite 1 facts facts

PiCUS Calliper Version 3

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Heat stress index. Dewpoint. pressure. altitude

Penetrometer for Soil and Snowpack Characterization

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

CapaciTorr HV Pumps. making innovation happen,together

Quantum Series Product Catalog

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

PRODUCT DATA SHEET. Eagle Eye Outdoor LED Module 5700K. RoHS Compliant. CUSTOMER :. DATE : REV : Rev. 2.0.

THE USE OF DEWAR CALORIMETRY IN THE ASSESSMENT OF CHEMICAL REACTION HAZARDS

Chapter Objectives. Chapter 9 Energy and Chemistry. Chapter Objectives. Energy Use and the World Economy. Energy Use and the World Economy

CLINICAL CHEMISTRY ANALYSER. The economical solution for all your needs GIVING YOU PEACE OF MIND

6 Securing of the delivery and acceptance

CHEMISTRY WORKSTATION. The power of proven quality GIVING YOU PEACE OF MIND

Air velocity & IAQ measuring instruments

A Brief Description of the Construction and Function of Common Electric Matches

Introduction to Bomb Calorimetry

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

CHM201 General Chemistry and Laboratory I Laboratory 7 Thermochemistry and Hess s Law May 2, 2018

DiSCmini. Handheld diffusion size classifier for nanoparticle measurement.

STANDARD OPERATING PROCEDURE

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

Dewpoint Meter Data Sheet / Instructions

Transcription:

CEO LETTER Digital Data Systems are the proud designers and manufacturers of CAL2K Isothermal Oxygen Bomb Calorimeter Systems, CAL3K Isothermal, Adiabatic and Dynamic Bomb Calorimeters The DDS CAL3K range is used to determine the calorific values of liquid and solid samples. The range of CAL3K oxygen bomb calorimeters is manufactured with various applications in mind; coal analysis and oil analysis being the most popular applications. The latest addition to the DDS Scientific range is the CAL3K-U bomb calorimeter, which is optimized for university use and educational institutions. The CAL3K-AP Oxygen Bomb Calorimeter combined the isothermal and adiabatic methods in one system. We call this new method dynamic. DDS has been designing and manufacturing high precision oxygen bomb calorimeters for over 30 years. The DDS Calorimeters are easy to set up, with easy removable connections, making the system compact, lightweight and easy to move - Rolf Ludwig

Who we are : A company introduction CAL3K Oxygen Bomb Calorimeter Systems Introducing the CAL3K range of oxygen bomb calorimeter systems from DDS Calorimeters DDS and CAL3K offers the new next generation advanced bomb calorimeter system with innovative technology and never before seen advanced features. The CAL3K range makes is possible to achieve a 5-6 minute operator time per test without compromising its accuracy or precision. After numerous determinations/sample analysis the vessel temperature rises and needs to be cooled for the next sample analysis. The external air cooler ensures that the vessel temperature is cooled to firing temperature in preparation for the next firing. Convenient Waterless System - The oxygen calorimeter is operated without water. No measuring, spilling or leaking. The calorimeter is ready to use without needing to fill it with water, reducing sample preparation time. The new air cooler also operates without water. The entire CAL3K calorimeter system requires no water making it environmentally friendly. Our CAL3K bomb calorimeters are designed to endure and sustain large pressure increases inside the calorimeter combustion chamber.

The bomb vessel is pressurized with 30Bar of pure oxygen in the initial period of the determination. The sample is then ignited in the firing period with electrical energy. During the main period the vessel is heated from the combustion of the sample. The pressure of the vessel rapidly increases with relation to the type of sample being burnt. A bomb calorimeter basically consists of a cup (crucible) to hold the sample, deflector plate, oxygen, a stainless steel bomb vessel, the insulating aluminium sleeve, the electronic controller card and the ignition system connected to the outside of the bomb for igniting the sample. One of the CAL3K-AP features is a micro-processor in the base of the bomb vessel for the automatic measurement of the calorific value of the sample. This unique design ensures no energy is lost or gained in the determination cycle, increasing the repeatable accuracy of the bomb vessel. The on-screen subject help is great way to have subject help at every step of the calorimeter operation Imagine having the choice of three calorimetry methods in one calorimeter system. The CAL3K range of calorimeters uses one, or a combination, of the following calorimetry methods, including: Isothermal, Adiabatic and Dynamic (Experimental). New and Improved Advanced Features Simplify your sample analysis workflow with new features introduced in the CAL3K range of oxygen bomb calorimeter systems. Existing features of the CAL2K Bomb Calorimeter have been improved and applied to the latest range of calorimeters from DDS Calorimeters, with some added advanced features to provide seamless operation and analysis. Explore the new features that the CAL3K has to offer and more, including upgraded and new features like : USB port communication, keyboard functionality, command explanations, subject help, bluetooth communication, calorimeter field testing, vessel testing, event logging, improved result storage, new operating modes, LIMS support, improved maintenance, calorimeter identification, vessel identification, improved temperature ranges, factory testing, hardware calibration, ambient temperature logging, improved initial firing conditions, autoincrementing SID, setting firing voltage, and serviceability

CAL3K Features The improved calorimeter system requires no water - that means no more leaks, spillage or measuring as the calorimeter has no water bucket. The new Isobatic calorimetry method combines the benefits of the Isothermal and Adiabatic methods to produce extremely accurate results at the highest speed possible. The Bayonet Oxygen Bomb Vessel is automatically filled and de-filled inside the calorimeter (only in the CAL3K-AP calorimeter). There is no need for an additional filling station as everything is done automatically inside the calorimeter. The dual language mode allows for English and one alternative language with help in different languages. A new features in our next generation oxygen calorimeters is the support of a mobile/smartphone device. A smart mobile device can now connect via Bluetooth and interface with the calorimeter to give you up to date information straight from the calorimeter. The CAL3K features full LIMS support for the assignment, scheduling and tracking of analytical samples and the associated analytical workload, as well as the storage of data associated with sample analysis. APPLICATIONS The CAL3K can be applied in the coal, petrochemical, medical research, cement, power generation and animal feed research industries. The CAL3K can also be used to analyze coal, coke, oil, foodstuff and biomass products and is applied in power plants, coal mines, metallurgy, the chemical industry, for commercial inspection and scientific research. The use of multiple bomb vessels minimizes the waiting period by preparing the second bomb with a sample while the current sample is being analyzed. Up to 10 bomb vessels can be prepared and used in the CAL3K-AP system with routine sample determination. We recommend 2 bomb vessels per system. A Greener Future The CAL3K Oxygen Bomb Calorimeter's small carbon footprint takes a step towards a greener future with lower power consumption. The calorimeter and cooler can run on 7AH (Amps per hour) for about 4 hours, and in the event of a power failure the calorimeter can run on a 12V battery.

APPLICATIONS The CAL3K can be applied in the coal, petrochemical, medical research, cement, power generation and animal feed research industries. The CAL3K can also be used to analyze coal, coke, oil, foodstuff and biomass products and is applied in power plants, coal mines, metallurgy, the chemical industry, for commercial inspection and scientific research. The use of multiple bomb vessels minimizes the waiting period by preparing the second bomb with a sample while the current sample is being analyzed. Up to 10 bomb vessels can be prepared and used in the CAL3K-AP system with routine sample determination. We recommend 2 bomb vessels per system. CAL3K-A Oxygen Bomb Calorimeter Superb Oxygen Bomb Calorimeters for Today's Analytical Needs. The CAL3K-A is the second in the range of innovative new oxygen bomb calorimeters from DDS. It is the companion product to the CAL3K-AP, but with external oxygen filling. The new range, from the engineers who designed the CAL2K oxygen bomb calorimeter range, features higher speeds and improved accuracy with a small carbon footprint (uses less resources; no water required, lower power consumption). Cal3k - A - Features

CAL3K-AP Oxygen Bomb Calorimeter Superb Oxygen Bomb Calorimeters for Today's Analytical Needs. The CAL3K-AP is the first in the range of innovative new oxygen bomb calorimeters from DDS. The new range, from the engineers who designed the CAL2K oxygen bomb calorimeter range, features higher speeds and improved accuracy with a small carbon footprint (uses less resources; no water required, lower power consumption). Cal3k - AP CAL3K-U Oxygen Bomb Calorimeter Cal3k - U CAL3K University Edition - Oxygen Bomb Calorimeter for Today's Analytical Needs. The CAL3K-U is the third in the range of innovative oxygen bomb calorimeters from DDS. It is the companion to the CAL3K-AP and CAL3K-A, but with external oxygen filling and without ATC. The new range, from the engineers who designed the CAL2K oxygen bomb calorimeter range, features higher speeds and improved accuracy with a small carbon footprint (uses less resources; no water required, lower power consumption). The external filling removes the pressure component from the CAL3K-U and has resulted in a more robust combustion calorimeter.

PROMO CAL3k - U Need more information? Get started by sending us an email to get in touch with an expert. Contact : Desiree (Sales) Tel : 011 792 9805 Email : calo@ddsystems.co.za