Hot Strain Gage Processing using ncode Glyphworks. Dave Woerner, Senior Principal Test & Durability Engineer, Faurecia

Similar documents
Because the third wire carries practically no current (due to the voltmeter's extremely high internal resistance), its resistance will not drop any

MET 301 EXPERIMENT # 2 APPLICATION OF BONDED STRAIN GAGES

STRAIN GAUGES YEDITEPE UNIVERSITY DEPARTMENT OF MECHANICAL ENGINEERING

What is a Strain Gauge? Strain Gauge. Schematic View Of Strain Gauge

MET 487 Instrumentation and Automatic Controls. Lecture 13 Sensors

Data Logger V2. Instruction Manual

Lecture 5: Using electronics to make measurements

Strain Gauge Application and Measurement of Unknown Load

Wheatstone Bridge Nonlinearity

CE 320 Structures Laboratory 1 Flexure Fall 2006

ENSC387: Introduction to Electromechanical Sensors and Actuators LAB 3: USING STRAIN GAUGES TO FIND POISSON S RATIO AND YOUNG S MODULUS

MEMS Report for Lab #3. Use of Strain Gages to Determine the Strain in Cantilever Beams

Lecture 5: Using electronics to make measurements

Strain Measurement. Prof. Yu Qiao. Department of Structural Engineering, UCSD. Strain Measurement

Electronics Resistive Sensors and Bridge Circuits

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 9

Excerpt from the Proceedings of the COMSOL Conference 2010 Boston

CEE575 - Homework 1. Resistive Sensing: Due Monday, January 29

Strain Measurements. Isaac Choutapalli

6. Strain Gages and Strain Measurement

1. Mark the correct statement(s)

TrueStructures TM Strain Analysis System

Temperature Compensation for MEAS Pressure Sensors

Sensors and Transducers. mywbut.com

Bending Load & Calibration Module

THERE MUST BE 50 WAYS TO FIND YOUR VALUES: AN EXPLORATION OF CIRCUIT ANALYSIS TECHNIQUES FROM OHM S LAW TO EQUIVALENT CIRCUITS

Mechatronics II Laboratory EXPERIMENT #1 MOTOR CHARACTERISTICS FORCE/TORQUE SENSORS AND DYNAMOMETER PART 1

Experimental Approach to Determine the Stress at a Section of Semi Circular Curved Beam Subjected to Out-Of-Plane Load Using Strain Rosette

Mechatronics II Laboratory EXPERIMENT #1: FORCE AND TORQUE SENSORS DC Motor Characteristics Dynamometer, Part I

TEMPERATURE COMPENSATION FOR MEAS PRESSURE SENSORS APPLICATION NOTE

Industrial Instrumentation Dr. Alok Barua Department of Electrical Engineering Indian Institute of Technology Kharagpur. Lecture - 4 Strain Gauge

Lecture 20. Measuring Pressure and Temperature (Chapter 9) Measuring Pressure Measuring Temperature MECH 373. Instrumentation and Measurements

Structures - Experiment 3B Sophomore Design - Fall 2006

Strain Gages. Approximate Elastic Constants (from University Physics, Sears Zemansky, and Young, Reading, MA, Shear Modulus, (S) N/m 2

I. MEASUREMENT OF TEMPERATURE

Experiment #6. Thevenin Equivalent Circuits and Power Transfer

Lecture - 2A Instruments-I

Exercise 2: Bending Beam Load Cell

UNIT 2 STRAIN MEASURMENTS, FORCE MEASUREMENTS. Therefore, resistance strain gauges are also known as piezo-resistive gauges.

MECHANICAL ENGINEERING TECHNOLOGY ESSENTIALS FOR LABORATORY REPORTS

DUBLIN INSTITUTE OF TECHNOLOGY Kevin Street, Dublin 8.

Load Cell Design Using COMSOL Multiphysics

Lecture 19. Measurement of Solid-Mechanical Quantities (Chapter 8) Measuring Strain Measuring Displacement Measuring Linear Velocity

Specific resistance of conductors

Temperature Measurements

UC Berkeley, EECS Department EECS 40/42/100 Lab LAB2: Electronic Scale UID:

Force Sensors. What is a force sensor?

The Strain Gauge. James K Beard, Ph.D. Rowan Hall Auditorium November 2, 2006

Strain Gages. Approximate Elastic Constants (from University Physics, Sears Zemansky, and Young, Reading, MA, 1979

Force and Displacement Measurement

STRAIN GAUGE MEASUREMENT

Experiment Five (5) Principal of Stress and Strain

1) Thermo couple sensor

Lab E3: The Wheatstone Bridge

Objective Type Questions Instrumentation System & Devices (IDS)

MENG 302L Lab 6: Stress Concentration

Biosensors and Instrumentation: Tutorial 2

DC Circuits Analysis

Multi-Capacity Load Cell Concept

Part 2. Sensor and Transducer Instrument Selection Criteria (3 Hour)

Industrial Instrumentation Prof. A. Barua Department of Electrical Engineering Indian Institute of Technology - Kharagpur

The gauge factor of a strain gauge relates strain to change in electrical resistance. The gauge factor G F is defined by the formula.

MAS.836 PROBLEM SET THREE

Laboratory 7 Measurement on Strain & Force. Department of Mechanical and Aerospace Engineering University of California, San Diego MAE170

Resistance Learning Outcomes

Strain Measurement MEASUREMENT EXPERIMENT

Industrial Electricity

Resistance Learning Outcomes. Resistance Learning Outcomes. Resistance

Solved Problems. Electric Circuits & Components. 1-1 Write the KVL equation for the circuit shown.

By Mir Mohammed Abbas II PCMB 'A' CHAPTER FORMULAS & NOTES. 1. Current through a given area of a conductor is the net charge passing

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad DEPARTMENT OF ECE QUESTION BANK. : G.Lakshminarayana, Asst.

Slide 1. Temperatures Light (Optoelectronics) Magnetic Fields Strain Pressure Displacement and Rotation Acceleration Electronic Sensors

Piezoresistive sensors

ELECTRICITY. Electric Circuit. What do you already know about it? Do Smarty Demo 5/30/2010. Electric Current. Voltage? Resistance? Current?

DC motors. 1. Parallel (shunt) excited DC motor

PHYS 2212L - Principles of Physics Laboratory II

Experimental Strain Analysis

Now let s look at some devices that don t have a constant resistance.


Chapter 18. Direct Current Circuits

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

AC : ENGINEERING SQUEEZEOMETER AND HUGGOME- TER

Chapter 6 Dynamics I: Motion Along a Line

ELECTRONIC SENSORS PREAMBLE. This note gives a brief introduction to sensors. The focus is. on sensor mechanisms. It describes in general terms how

Chapter 6: Series-Parallel Circuits

Resistance : R = ρ( ) units are Ohms ( 14 ) Resistor 100 ohms

Applying the Wheatstone Bridge Circuit

Chapter 33 - Electric Fields and Potential. Chapter 34 - Electric Current

Basic Electricity. Unit 2 Basic Instrumentation

MECHANICAL TESTS FOR UMBILICALS

Last Revision: August,

Electricity MR. BANKS 8 TH GRADE SCIENCE

Design and Development of Impact Load Sensor for Dynamic Testing Purposes

AOE 3054 Measuring static displacement and deformation in structures

LMM-H04 Mass Air Flow Sensor

Experimental Stress Analysis of Curved Beams Using Strain Gauges

What is dynamic electricity?

Elasticity: Term Paper. Danielle Harper. University of Central Florida

AN INTRODUCTION TO NUMERICAL METHODS USING MATHCAD. Mathcad Release 14. Khyruddin Akbar Ansari, Ph.D., P.E.

1.105 Solid Mechanics Laboratory Fall 2003

Transcription:

Hot Strain Gage Processing using ncode Glyphworks Dave Woerner, Senior Principal Test & Durability Engineer, Faurecia

Acknowledgements Mr. John Menefee, FECT For Python Script Programming 2

Motivations

Motivations: Exhaust Systems Road Load Data Acquisitions use a bypassed exhaust. HOWEVER packaging close to the engine OFTEN precludes bypassing the exhaust system BEFORE the Catalytic Converters The Classic Bonded Resistance Strain Gage can only handle temperatures up to near 200 C CONSEQUENCE: Bonded Resistance Strain Gages Burn UP &/or Data is Unreliable due to Temperature affects! 4

Motivations: On the other hand Hot Strain Gages can handle temperatures of up to 650 700 C: But Hot Strain Gages are: More Expensive (up to $2000 per gage) Require a thermocouple to use properly (Another Channel) AND Require special processing due to their non-linearity with respect to temperature. This presentation shows how using ncode for processing (for a particularly complicated) hot strain gage, EVEN when the environmental temperature is fluctuating (dynamic). 5

Some Strain Gage Basics

Some Strain Gage Basics: Wheatstone Bridge A strain gage measures micro-strain (ue) Strain is DIRECTLY proportional to Displacement (of the part it is mounted on. Motivations A strain gage (at a constant Temperature) is a Linear Device Strain gages are basically a grid of little wires that when the part they are glued to is loaded (bent) stretch or compress, and the resistance of the grid changes. So if R1 = R2 = R3 = 120 Ohms, and the active arm (G1) is 120 Ohms when it is at rest, The Constant of Proportionality for Length to Strain is the Gage Factor

Some Strain Gage Basics Here is the Single Arm Circuit again, but now I have introduced Long Lead wires, which have their own resistance: RL This Lead Wire Resistance REDUCES the GAGE FACTOR (k)

Some Strain Gage Basics If I apply a bending load and the resistance of the active arm goes up to 121 ohms then my circuit output is: (This is just a voltage divider) Eex * 120/(120+121) Eex* 120/(120+120) = Eex *(0.49792531 0.5) = Eex * (- 0.002074689) (If Eex = 10V then 10*(0.002074689) = - 0.020747!) 9

Some Strain Gage Basics Now if I mount a strain gage on the top of the beam, and another on the bottom of the beam, and Push Down (P) R1 will be in Tension, and its resistance will Increase. R4 will be in Compression, and its resistance will Decrease Motivations Here is the Circuit again, but showing the two gages: R1 = G1 & R4 = G4 If now I let Eex = 10 Volts, and my STRAIN Change in resistance (still) = 1 ohm: (then G1 = 121 ohms & G2 = 119 ohms), (& R2 = R3 = 120 ohms Still!) Then e0 = 10V * [119/(119+121) 120/(120+120)] = -0.04166667 Volts I have basically DOUBLED my Sensitivity!

Some Strain Gage Basics HERE we apply a bending load and the bending resistance of the active arm goes up to 121 ohms, But if we add heat!, The Resistance Change due to TEMPERATURE Much Bigger: 10 Ohms Here is the Math: 10V * (120/(120+131) 120/(120+120)) = 10V * (0.4780876 0.5) = 10V * (0.021912350) = - 0.219!! CONTRAST THIS w/ Previous value of - 0.020747 ITS AN ORDER OF MAGNITUDE ERROR!! 11

Hot Strain Gages Basics 12

Hot Strain Gages Basics Now Suppose I have TWO ACTIVE ARMS: G1 is changing with both Strain (1 ohm) & Temperature (10 ohms) But R4 is ONLY CHANGING WITH Temperature (10 ohms)! This is how the Kyowa ½ bridge gage works.

Hot Strain Gages Basics If the Temperature Change is CONSTANT! i.e. 10 ohms = Thermal Change in our example Bending strain = 1 ohm still Then the new equation is: e0 = 10V * [130 / (131 + 130) 120 / (120 + 120)] = 10V * ( 0.49808 0.5) e0 = - 0.019157088 I am almost back to where I started (-0.020747) But Gage Factor k changes because the Lead Wire resistance also Changes with temperature:

Hot Strain Gages Basics This is essentially what we have in a hot Strain gage: Thermocouple 15

Hot Strain Gages Basics Here you can see the lead wires bonded to the Converter Can: Thermocouple 16

A Real Hot Strain Gage

A REAL Hot Strain Gage We are going to use as an example the Kyowa ½ Bridge Hot Strain gages for the rest of this presentation. They work just like the strain gage in the previous section. Kyowa (and others, Hi Test, Vishay, etc.) make ¼ Bridge gages. Those gages lack the dummy gage that is thermally active but not responsive to strain. You give up accuracy with them, and the thermal drift can t be as easily separated from the strain measurements. Just removing the running mean doesn t work, because the temperature isn t constant. 18

A REAL Hot Strain Gage An Unmounted Kyowa gage showing the circuit board & the Circuit Schematic 19

A REAL Hot Strain Gage SUMMARY The Kyowa KHCR gages, come with an electrical bridge completion circuit built in. Our standard setup for the edaq Acquisition system is: 120 Ohm nominal edaq Strain Setting. Full Bridge Configuration Hot Strain Output Gages Resistance Basics from the Data Sheet. Typically ~ 114 120 ohms. Room Temperature Gage Factor entered from the Data Sheets Typically around 1.5 The Hot Strain Gages come with a section of wire that needs to be mounted to the heated pipe. For our KYOWA KHCR gages, the heated wire (M1) length is typically 0.55 meters (55 centimeters). 0.4 meters is in the tabulated data from Kiowa. We want to match this for this installation. Our previous experience with these gages has told us that the longer lengths heated wire are more stable than using one of the shorter lengths. We want to mount this gage on the part, away from the flange so that we don t have any stress risers in the heated wire. 20

A REAL Hot Strain Gage Basically, in addition to what we have seen in our hot gage basics there is a circuit board where 120 ohm bridge completion part lives. They mount balancing resistors to make the 120 ohm resistor half of the circuit balance against the hot part of the circuit. Hot Strain Gages Basics The key equation for calculating the true strain is: Actual Strain @ Temperature = * ( 2 / Gage Factor) [Measured Strain Apparent Strain] 21

Here is the Data Sheet (EACH ONE IS UNIQUE): Motivations

A Real Hot Strain Gage This is a close up of the tabulated data sheet for the Kyowa Hot Strain Gage type KHCR, Serial Number #B- 267. NOTICE: The apparent strain @ a given temperature and the gage factor @ that temperature are tabulated. When one measures the unstrained part at temperature, you get these strain values. The APPARENT STRAINS must be removed 23

A REAL Hot Strain Gage The most important thing to realize is that the curves that are plotted for temperatures (on the previous slide) are characterized by set of equations. THESE EQUATIONS are unique in terms of co-efficients, exponents & SIGNS for each gage!! 24

A REAL Hot Strain Gage: SUMMARY The formula for converting measured Strain (including the BOTH Thermally Induced Apparent Strain and Thermally Induced Gage Factor is: Actual Strain @ Temperature = [Measured Strain Apparent Strain] * ( 2 / Gage Factor) Or: ue @T = [Measured ue ue(app)] * (2 / GF) For an UNLOADED Part, the Strain should be Zero: So, Applying equation 1 to collected data at a known temperature should take Measured Strain back to Zero!! This must be done UNIQUELY for each gage @ each temperature!! 25

Developing ncode Glyphworks Processing 26

Developing ncode Glypworks Processing This is a Hill Road event where you are driving (and accelerating) up and down hills around a road course. The strains are on a converter flange so most of it is engine roll. If we had a constant temperature this is what the adjustment would look like. 27

Developing ncode Glypworks Processing This flow does the equation calculations at a constant temperature 28

Developing ncode Glypworks Processing Detail of the Time Series Calculator (this is just the equation 1) : At a CONSTANT TEMPERATURE ue @T = [Measured ue ue(app)] * (2 / GF) 29

But Temperature Isn t Constant!!! So we developed a Glyph that calculates the equations in the Data Sheet for at each temperature. This reproduces the curves and can be used to check our math & data entry:

Developing ncode Glypworks Processing 31

Developing ncode Glypworks Processing The Equations (we edit these for each gage), [this is just a screen snapshot of the guts of the scripting glyph. 32

Processing Thermally Dynamic Hot Strain Gage Data 33

Processing Thermally Dynamic Hot Strain Gage Data This Flow takes files, processes them sequentially & then writes them out: It separates out the temperature files, up samples the temperature data and filters itso you have the same number of points as the strain time history The Scripting glyph takes the two inputs (u-e & T) and processes each data point & then writes them out: 34

Processing Thermally Dynamic Hot Strain Gage Data Again we have the same equation section that we had before: 35

Processing Thermally Dynamic Hot Strain Gage Data Here is a Dynamically adjusted temperature channel, including the temperature channel (selected because it varies a lot) 36

Processing Thermally Dynamic Hot Strain Gage Data Questions? 37

Some useful references: Kyowa Corporation Vishay Corporation The Bonded Resistance Strain Gage by William Miller & William Murray Strain Gage Basics by Hathaway & Long 38

Thank you! Dave Woerner, Senior Principal Test & Durability Engineer Faurecia measure and predict with confidence