Grounding and Shielding

Similar documents
Charge readout and double phase

Upgrade plans for the ATLAS Forward Calorimeter at the HL-LHC

The ATLAS Liquid Argon Calorimeter: Construction, Integration, Commissioning Ph. Schwemling on behalf of the ATLAS LAr Group

LHC HTS CURRENT LEADS

CRYOGENIC CONDUCTION COOLING TEST OF REMOVABLE PANEL MOCK-UP FOR ITER CRYOSTAT THERMAL SHIELD

The Design and Fabrication of a 6 Tesla EBIT Solenoid

Microscopy Cryostat System

THE CERN CRYOGENIC TEST FACILITY FOR THE ATLAS BARREL TOROID MAGNETS

Critical parameters of

Feasibility of HTS DC Cables on Board a Ship

Cryo Mezzanine Design and Requirements. David Montanari, Aurélien Diaz, Kevin Haaf LBNF Cryostat, final design review SURF, August 2017

EXEMPLAR NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL PRINCIPLES AND PRACTICE NQF LEVEL 3 ( ) (X-Paper) 09:00 12:00

The KATRIN experiment

HIMARC Simulations Divergent Thinking, Convergent Engineering

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

Superconducting Magnet with a Minimal Steel Yoke for the Future Circular Collider Detector

CURRENT LEADS FOR THE LHC MAGNET SYSTEM

ATLAS Hadronic Calorimeters 101

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

EXPERIMENT 9 Superconductivity & Ohm s Law

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Cryogenic and Electrical Test Results of a 30 M HTS Power Cable

Evaluating ATLAS LAr Front End Board Performance

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

Muon reconstruction performance in ATLAS at Run-2

Gesellschaft für Schwerionenforschung mbh (GSI), Planckstrasse 1, D Darmstadt, Germany

MODEL: WB009GMFI19HLD (120V) Wall Mount DC Inverter Fan Coil Unit 9,000 BTUH

Hydra Fault Current Limiting HTS Cable to be Installed in the Consolidated Edison Grid

Measurements of temperature on LHC thermal models

Measurement of Tritium in Helium

Les Premières Données dans ATLAS et le Calorimètre à Argon Liquide

The Cylindrical GEM detector for the KLOE-2 Inner Tracker

Analysis of Eddy Current Distributions in the CMS Magnet Yoke during the Solenoid Discharge

Electronic calibration of the ATLAS LAr calorimeter and commissioning with cosmic muon signals

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

EDIPO Test Facility User Specification

Multiphysics Simulations for the design of a Superconducting magnet for proton therapy

Physics 196 Final Test Point

Thermal Field in a NMR Cryostat. Annunziata D Orazio Agostini Chiara Simone Fiacco

The Silicon-Tungsten Tracker of the DAMPE Mission

DEO XGEM SHIELDING CERN / AD Bertrand LEFORT (TSO) 5/6/2012

System design of 60K Stirling-type co-axial pulse tube coolers for HTS RF filters

He II Heat transfer through a Corrugated Tube - Test Report

The Q Machine. 60 cm 198 cm Oven. Plasma. 6 cm 30 cm. 50 cm. Axial. Probe. PUMP End Plate Magnet Coil. Filament Cathode. Radial. Hot Plate.

INSTITUTE OF AERONAUTICAL ENGINERING DUNDIGAL ELECTRICAL AND ELECTRONICS ENGINEERING

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

RC Circuit (Power amplifier, Voltage Sensor)

Electrostatics. Apparatus:

ATLAS Tile Calorimeter Calibration and Monitoring Systems

PHY 101 Practice Exam III Monday, November 27, 2:15-3:35PM

Physics 2220 Fall 2010 George Williams THIRD MIDTERM - REVIEW PROBLEMS

PHY3901 PHY3905. Hall effect and semiconductors Laboratory protocol

ELECTRO MAGNETIC FIELDS

Helium two-phase flow in a thermosiphon open loop

STATUS OF ATLAS TILE CALORIMETER AND STUDY OF MUON INTERACTIONS. 1 Brief Description of the ATLAS Tile Calorimeter

Alternating Current (AC): Alternating Current is electric current that reverses directions at regular intervals.

PHYS320 ilab (O) Experiment 2 Instructions Conservation of Energy: The Electrical Equivalent of Heat

Flow-meter calibrations for the ID of the ATLAS Experiment

Calorimetry in particle physics experiments

PREX Simulation Update

Introduction to Blackbody Sources

Instruction Manual for EP-20 e/m of the Electron Apparatus

Examination Heat Transfer

Commissioning of the ATLAS LAr Calorimeter

Commissioning testing of a 1 MVA Superconducting transformer featuring 2G HTS Roebel cable

PASSIVE COMPONENTS FOR A 3D ENVIRONMENT

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

Status of the physics validation studies using Geant4 in ATLAS

Demonstration 1: Faraday Ice Pail and Charge Production

ORTEC. SLP Series Silicon Lithium-Drifted Planar Low-Energy X Ray Detector Product Configuration Guide

Electrization of the superconductive windings and tori and the new type of contact potential difference

Cryostat Assembly. 17 September Martin Nordby, Rafe Schindler, Gary Guiffre, Rick Van Berg

Electrostatics x C.

5 Hadronic calorimetry

Latest Status of High Temperature Superconducting Cable Projects

Ch. 3. Pulsed and Water Cooled Magnets. T. J. Dolan. Magnetic field calculations

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

The development of a Roebel cable based 1 MVA HTS transformer

Solution for Fq. A. up B. down C. east D. west E. south

Lab 1: Determination of e/m for the electron

SPIRAL 2 Commissioning Status

Agenda for Today. Elements of Physics II. Lenz Law. Emf opposes change in flux Faraday s Law Induced EMF in a conducting loop

THE CHARGE-TO-MASS RATIO OF THE ELECTRON (e/m)

user's manual nx frequency converters resolver option board opt-bc

Code No: RR Set No. 1

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

D- Charge Exchange Ionizer for the JINR Polarized Ion Source POLARIS

Report CERN-ACC Considerations for a QD0 with Hybrid Technology in ILC

Status & Plans for the TRIUMF ISAC Facility

PHY 1214 General Physics II

Determining Characteristic Impedance and Velocity of Propagation by Measuring the Distributed Capacitance and Inductance of a Line

High-temperature superconducting magnet for use in Saturated core FCL

Silicon Detectors. Particle Physics

Magnetic Field measurements with Csmagnetometers

Experimental Investigation of High-Temperature Superconducting Magnet for Maglev

To be published in the Proceedings of ICEC-22, Seoul Korea, July 2008 MICE Note 232 1

Flow Measurement. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/22 Siemens FI

PRACTICE EXAM 2 for Midterm 2

Fault Current Limiter Based on Coated Conductor

Status and Progress of a Fault Current Limiting HTS Cable To Be Installed In The Consolidated Edison Grid

Transcription:

Grounding and Shielding Veljko Radeka, BNL Outline Primary guidelines The Liquid Argon Calorimeter system Prevention of EMI and isolation Safety grounds Interface with other subsystems Status of implementation and open questions 17 Jun 02 LAr Electronics ASSO Review Grounding and shielding 1

Primary Guidelines Derived from the ATLAS Policy on grounding http://atlas.web.cern.ch/atlas/groups/frontend/ground.htm 1. All detector subsystems will be electrically isolated 2. There will be no connection to ground other than Safety Networks 3. There will be no connection between different detector subsystems Other detailed guidelines have been derived from this primary ones Isolation of power supplies Signal communications by electro-optical or differential transmission lines Detectors in Faraday cages Compatibles with existing safety policies at CERN: Hazard identification by systematic methods (ex. fault tree analysis) Establish a procedure/inspection to verify that the detector design does not compromise safety 17 Jun 02 LAr Electronics ASSO Review Grounding and shielding 2

The Liquid Argon Calorimeter system Key points in the implementation of electrical isolation within the subsystem and with respect to other subsystems: 1. Carefully designed faraday cage 2. Clock, trigger, data through optical fibers 3. LVL1 sums Differential transformer Coupled 4. Separate power return for every voltage in each crate 5. LV, HV supplies floating (with safety connections) 6. Mechanical support insulating 7. LAr cryogenics and cooling lines floating 8. Solenoid lines insulated, power supplies floating 9. Slow controls Optical or transformer coupled 10. Sensors isolated 11. General checking for inadvertent connections to various grounds 17 Jun 02 LAr Electronics ASSO Review Grounding and shielding 3

Prevention of EMI and isolation (1) To avoid coherent signals in group of read-out channels Noise from digital circuits generated locally on a single read-out board in the crate Cured by careful design of layout, filtering on the board, shielding of preamplifiers, minimization of digital operation on the board EM radiation surrounding the electronics and noise induced by penetration into cryostat/crates Cured by well designed Faraday cage comprised of the cryostat, the feedthrough and the crates. No electrical penetration in the cryostat except for signal and high voltage feedthrough All services (pressure and temperature) filtered in the crates and fed into the cryostat on shielded cables 17 Jun 02 LAr Electronics ASSO Review Grounding and shielding 4

ATLAS LAr Calorimeter Readout Electronics Faraday Cage

LAr Cal. Vital lines (i.e., Potential ground loops) 1. Lar cryo lines 2. HV supplies 3. Data (opt. fibers) 4. Cooling circuit (water) FEE ~20m ~70m 5. LV supplies 6. Level 1 sums ~ 5 10 3 channels 7. clock warm cold Accordion 8. slow control (parameter input) 9. sensors 10. solenoid cryo & supply 1., 4., 11. insulators 2., 5. floating supplies, as in Fig.2 6. differential transmission transformers (balun or signal) 7., 8. opto-couplers (or transformers) 9. insulate sensors; different techniques at various receivers 10. solenoid line to be insulated, power supply floating 12. heater insulated, capacitors to pedestal, floating supply 11. mechanical supports 12. feedthrough heater (dc) Fig. 1

1. Coaxial Cables Rules for Entering the Cryostat Shield connected to cryostat before penetrating Faraday cage Short connection, low inductance LAr Cryostat Performed on standard feedthroughs 2. Power Supplies Capacitors with short leads, close to cryostat low inductance connection No net DC Current in Balun to avoid saturating Ferrite (pass power and return). In magnetic field up to ~ 300 400 gauss, use 3D3 type ferrite B 100 n Balun + 0 _ 100 n LAr 100 n Cryostat 10µ + 0 _ 5-10 turns on Ferrite core to floating power supply S i = 0 1.27 cm 3. Probes, HV r to electrode LAr 100 n 100 n Capacitors with short leads, close to cryostat, low inductance connection R > 1 kw can be replaced by L > 1mH when no current flows R Fig. 3

Well defined safety ground Safety grounds The ground should be at USA15 To preserve from EMI the Level 1 trigger sum signals The grounding scheme should extend the faraday cage of the calorimeter to include the twisted pair cables coming from the trigger sum board. The common braid of Level 1 cables from each crate needs to be connected to the safety ground (through a ~ 2 cm braided Cu cable) Supplementary safety grounds If the analysis of the whole subsystem identifies a component which if accidentally disconnected could present hazard, then the component must have a supplementary ground connection Such a connection should be through a nonlinear element. 17 Jun 02 LAr Electronics ASSO Review Grounding and shielding 10

Prevention of EMI and isolation (2) Currents coming through ground loops It is the most demanding issue since it involves potential connections to equipments at various distance from the cryostat Basic design approach: isolate each cryostat with its read-out from everything else Only one location where a connection to ground will be allowed for DC and low frequencies Cryostats must be insulated at their supports and in all cryogenics lines and services Each read-out crate has to be connected to his own floating power supply The two halves of the accordion stack will be insulated from each other and from their supports and connected to the cryostat at their feedthroughs via signal cables EM end-caps will be treated in the same way 17 Jun 02 LAr Electronics ASSO Review Grounding and shielding 7

Safety Ground Detector PA, SCA, ADC 50 ~ 75m Signal & control > 10 µh Level 1 room Receivers DAQ Cs Floating supplies > 100 µh Safety ground

17 Jun 02 LAr Electronics ASSO Review Grounding and shielding 9

Low Voltage Switching Supplies and Rectifier Detector AC Neutral GFI DC 200 V- 300 V 10 20 Α 50-75 m Fuse ~ LV Isolated Switching Supply 3 V-12 V Shield connected only at the sending end CRYOSTAT CRATE SAFETY GROUND in Level 1 Room

17 Jun 02 LAr Electronics ASSO Review Grounding and shielding 11

3.1 Cryostat/solenoid insulation The general requirement is that the cryostat (both warm and cold walls) are to be isolated electrically from the solenoid and its service. Some specific steps agreed upon in discussions with the cryostat team and the solenoid team are listed here: 3.1.1. The solenoid coil, superconducting bus lines and its associated services, i.e., the support cylinder, radiation shield panels, and cooling tubes, are to be electrically isolated from the LAr cryostat cold vessel and the warm vacuum vessel. 3.1.2. The solenoid coil will be electrically floated in the LAr cryostat, but will be grounded with a resistance of 1-10 k-ohm at the coil power supply (8,000 A). This is important in order to monitor the coil against any other conductive paths (shorts) to ground. This is also consistent with the ATLAS guidelines for all superconducting magnets. The solenoid power supply must minimize the voltage excursions with respect to ground. 3.1.3. The associated solenoid services are electrically insulated from the LAr cryostat, but they are electrically connected to the support structure for the ATLAS detector together with the solenoid chimney, the control dewar and common cryogenics ( to be provided by CERN). 3.1.4 The (thermal) super insulation between the LAr cryostat and the solenoid must include electrical insulation. This can be achieved by adding a few layers of Kapton/mylar. Special care must be taken that there are no penetrations that allow electrical contact and violate electrical insulation. This has to be realized, while allowing sufficient passages to evacuate the solenoid vacuum space.

3.1.5. The solenoid chimney and control dewar will have to share a common vacuum with the LAr cryostat, but they must be isolated from the LAr cryostat. Consequently, an insulation flange (such as a G10 disk) is required at the nearest location (order of 20-30 cm) from the bottom of the chimney ( the chimney is directly connected to the warm wall of the LAr cryostat). 3.1.6. The solenoid services in the chimney area are electrically a part of the solenoid, as is ALL of the solenoid monitoring equipment, and thus are insulated from the cryostat. 3.1.7. Special care must be taken to minimize fluctuations in the voltage across the solenoid. At present, the expected fluctuations are: +/- 12 V in normal operation and 0 to - < 500 V in case of emergency (such as power supply switching off due to power failure or the magnet quench).

3.2 Insulation between the central tracker and the cryostat The general requirement is that the cryostat be isolated electrically from the central tracker and its associated services. Items of concern for isolation between these two subsystems are as follows: 3.2.1. Tracker support rails. The tracker support rails are welded to the cryostat, and thus electrically are part of the cryostat. Consequently, the central tracker has to be insulated from the rails. 3.2.2. Tracker services supported on the cryostat inner warm wall. The tracker plans to support part of its services on the cryostat inner wall. These include cooling lines, signal and power cables. All of these have to be insulated from the cryostat inner wall. 3.2.3. Tracker services on the cryostat head-vessel. Some of the tracker services will be supported on the cryostat head-vessel. All of these services will have to be insulated from the cryostat head vessel. 3.2.4. Tracker services in the gap region. All the tracker services in the gap, including cooling pipes, cooling manifolds, and patch panels for the electrical connections, need to be supported by the cryostat and tile calorimeter. ALL are to be electrically insulated from the cryostat, as well as from the readout electronics crates that are electrically part of the cryostat. 3.2.5. Beam support. The beam is suspended from the cryostat head-vessel and the support has to be electrically insulated from the head-vessel so that there is no electrical contact between the beam pipe and the cryostat.

3.3 Insulation between the tile calorimeter and the cryostat The general requirement is that the cryostat has to be isolated electrically from the tile calorimeter. Insulation of support interfaces and LAr services in the space between the tile calorimeter and the cryostat concerns the following items. 3.3.1. Cryostat support legs. The cryostat support legs, that are attached to the tile by bolts, are connected to the tile calorimeter. The support stubs are connected to the cryostat. In between, there will be a thin G10 insulation that will insulate the legs electrically. 3.3.2. Cryostat wall and the tile inner surface. There is nominally 2 cm of stay-clear area between the cryostat and the tile calorimeter. So, in principle, they should not touch. It is, however, very difficult to guarantee that no loose conducting material will be dropped into that region during assembly. It is recommended that a thin layer of G10, or some other insulating material, be placed in that region to insure electrical isolation. (As some means of protection from accidental LAr spill has been suggested, the same "sheet" could also insure that no liquid drops on the tile.) The responsibility for implementation of this insulating sheet should be defined. 3.3.3. Cooling manifolds for the readout electronics. The cooling manifolds are not in electrical contact with the readout. The insulation will be made in the tubes that connect the manifold to the cooling plates attached to the front end electronics boards in the readout crates. 3.3.4. Power supplies for readout crates. The dc-dc converter solution, being investigated to locate the power supplies at the readout crates, will require that the dc-dc converter be supported in the gap and/or in the tile finger region. The dc-dc converter will have to be insulated from the tile.

3.3.5. LAr cables in the gap region. All cables that are part of the LAr subsystem will be isolated from the tile. It is also the responsibility of the LAr subsystem to insulate any cable shields from any cable trays attached to the tile calorimeter. 3.3.6. Tracker services supported on the tile calorimeter. All tracker services that have to pass through the gap will be insulated from the LAr calorimeter. These include all of the cooling pipes, cables, trays, etc. These services have to pass through the tile fingers and the isolation at that point should be defined by the tracker and the tile calorimeter subsystem.

3.4 Cryogenics and vacuum lines isolation The general requirement is that the cryostat has to be isolated electrically from the cryogenics and vacuum lines. The cryostat is considered as an entity, since the cold vessel is connected to the warm vessel by the very low resistance of signal returns of all vacuum cables (inside the feedthroughs) in parallel. 3.4.1. LN2 cooling lines: input and output. There are three nitrogen input and output lines per side in the barrel and two per end cap. They will be insulated by using G10 in the bayonets on the cold and warm lines. The bayonets are installed near the cryostat, about 40 cm from the outer radius of the cryostat. The design for the insulation will be done by the cryogenics team. 3.4.2. LAr fill line, LAr vacuum exhaust line and LAr dump line. The vacuum space in the LAr fill line is also used as an exhaust in case of a liquid spill to the warm vessel. Thus it has a 6 inch diameter pipe coming out on the side. The lines and the exhaust line have to be insulated.

Status of the policy (1) The key elements where possible are part of the design: 1. Most of the elements have been properly designed 2. Some concerns remains in the integration of LAr DCS with the overall DCS An overall review at ATLAS level is advisable 3. Interfaces with other subsystems should be reviewed The cooling system is under design with isolation The distribution of ATLAS services is not final Not all subsystems have a final design in place which can be reviewed against ATLAS grounding policy The LAr grounding policy is not formalized: Some documents exist but they are NOT easily accessible An overall EDMS document needs to be written A check list is needed to verify that the grounding policy is applied During integration and installation During commissioning 17 Jun 02 LAr Electronics ASSO Review Grounding and shielding 12

Example of Grounding Configuration Document Power From/To Service type Total/crate Total Actual Sizes (mm) Responsible Grounding Local Power bus 1 NA H. Takai Grounded to Crate through FEB connections Local Power cables in the Gap 10 (5/crate side) NA 15 O.D. each H. Takai Grounded to Crate Local (In the finger region) Power supply to USA1 5 Power supply to 300 Volt power Supply Power supply to ELMB Power Supply 300 V Input cable (shielded twisted pair cable) Interlock for the power supply Power supply monitoring cable NA 1 16/face 1/crate 1 (4 wires) 1 (Up to 24 wires, 1 0 + 10 +4 lines, Voltages, Current, Temperatur e) 16/face 32 total 16/face 32 total 16/face 32 total 32 total 5 O.D. each 5 O.D. each 20 O.D. each 300x300x 150 each Floating Supply, grounded to crate through low voltage cables H. Takai Shielded cable, connected to ground only at the 300V end. H. Takai To be determined H. Takai To be determined

Status of the policy (2) The day-by-day verification of the application of the grounding rules needs to be organized: The integration phase of the calorimeters is already started. Feedthrough, pedestals, cryogenics lines, vacuum lines etc. are being installed A supervisor of these activities needs to be nominated 17 Jun 02 LAr Electronics ASSO Review Grounding and shielding 13