J. S. Cha\ S. M. Ghiaasiaan\ C.S. Kirkconnell^, W.M. Clearman\

Similar documents
Comparison of Fluid Flow and Heat Transfer for 1D and 2D Models of an In-Line Pulse Tube Refrigerator

Thermal Dispersion and Convection Heat Transfer during Laminar Transient Flow in Porous Media

Flow and Heat Transfer Processes in an Inertance type Pulse Tube Refrigerator

CFD Modeling of Tilt Induced Cooling Losses in Inertance Tube Pulse Tube Cryocoolers

PERFORMANCE INVESTIGATIONS OF SINGLE STAGE STIRLING TYPE PULSE TUBE CRYOCOOLER WITH INERTANCE TUBE USING CFD SIMULATIONS

HYDRODYNAMIC PARAMETERS OF MICRO POROUS MEDIA FOR STEADY AND OSCILLATORY FLOW: APPLICATION TO CRYOCOOLER REGENERATORS

Theoretical Analysis and Optimization of Regenerator of Stirling Cryocooler

A Thesis Presented to The Academic Faculty. William M. Clearman

Drag Coefficient and Nusselt Number for Laminar Pulsating Flow in Porous Media

A Model for Exergy Efficiency and Analysis of Regenerators

Phase Shift Characteristics of Oscillating Flow in Pulse Tube Regenerators

A Model for Parametric Analysis of Pulse Tube Losses in Pulse Tube Refrigerators

Oscillating Flow Characteristics of a Regenerator under Low Temperature Conditions

Parametric Numerical Study of Off-Axis Pulse Tube Losses

Design of Standing Wave Type Thermoacoustic Prime Mover for 300 Hz Operating Frequency

A pulse tube refrigerator below 2 K

Thermoacoustic analysis of a pulse tube refrigerator

A Numerical Model of Regenerator Based on Lagrange Description

NUMERICAL ANALYSIS OF DOUBLE INLET PULSE TUBE REFRIGERATOR. Samarendra Panda Roll No.: 213ME5452

Experimental Investigation on a Single-Stage Stirling-Type Pulse Tube Cryocooler Working below 30 K

System design of 60K Stirling-type co-axial pulse tube coolers for HTS RF filters

Experimental Investigation of Hybrid System Pulse Tube and Active Magnetic Regenerator

Visualization of Secondary Flow in an Inclined Double-Inlet Pulse Tube Refrigerator

An Eulerian-Lagrangian model to study the operating mechanism of Stirling pulse tube refrigerators

PERIODIC FLOW HYDRODYNAMIC RESISTANCE PARAMETERS FOR VARIOUS REGENERATOR FILLER MATERIALS AT CRYOGENIC TEMPERATURES

Cryocoolers (CryoCoolers.tex)

Numerical Simulation of the Effect of Heat Conductivity in a 4 K Regenerator

Thermodynamic Comparison of Two-Stage Pulse Tube Refrigerators for Two Different Configurations

Development of a 4K Pulse-Tube Cold Finger for Space Applications

Development of high-efficiency Stirling cryocoolers for high temperature superconducting motors

New Regenerator Design For Cryocoolers

Electric-Mechanical-Acoustic Coupling Characteristics for Pulse Tube Cryocoolers

Compression Losses In Cryocoolers

Performance analysis of a miniature Joule Thomson cryocooler with and without the distributed J T effect

A Numerical Estimate of Flexible Short-Tube Flow and Deformation with R-134a and R-410a

MINIMIZATION OF ENTROPY GENERATION AND PRESSURE DROP FOR HYBRID WIRE MESHREGENERATIVE HEAT EXCHANGER

Theoretical and Experimental Research on a Two-Cold-Finger Pulse Tube Cooler

Numerical Simulation of Oscillating Fluid Flow in Inertance Tubes

Modelling of Cryocoolers

Key-Words: Porous media, Oscillating flow, Pressure loss, Darcy, Forchheimer.

Performance Evaluation of 0.5 W at 80 K Stirling Cryocooler

Studies on flow through and around a porous permeable sphere: II. Heat Transfer

IMECE PULSE TUBE CRYOCOOLER DYNAMICS AND SIMULATION

Mathematical Modelling for Refrigerant Flow in Diabatic Capillary Tube

SIMULATION OF FLOW IN A RADIAL FLOW FIXED BED REACTOR (RFBR)

Strength Study of Spiral Flexure Spring of Stirling Cryocooler

This section develops numerically and analytically the geometric optimisation of

Natural Convection in Vertical Channels with Porous Media and Adiabatic Extensions

Numerical Analysis of Transport Phenomenon Inside a Pulse Tube Refrigerator Coupled with Fuzzy Logic Controller

Analysis of the Cooling Design in Electrical Transformer

Keywords: Spiral plate heat exchanger, Heat transfer, Nusselt number

Circular Bearing Performance Parameters with Isothermal and Thermo-Hydrodynamic Approach Using Computational Fluid Dynamics

EXPERIMENTAL AND NUMERICAL STUDIES OF A SPIRAL PLATE HEAT EXCHANGER

Proton Conductive Membrane Compressor-Driven Pulse Tube Cryocooler

Onset of levitation in thrust bearing: FSI study using Abaqus-FlowVision coupling

Analysis of Fluid Film Stiffness and Damping coefficient for A Circular Journal Bearing with Micropolar Fluid

Numerical simulation of pulse-tube refrigerators : 1D model Lyulina, I.A.; Mattheij, R.M.M.; Tijsseling, A.S.; de Waele, A.T.A.M.

Differential relations for fluid flow

CFD Modeling of Reciprocating Flow around a Bend in Pulse Tube Cryocoolers

Numerical Simulation of Heat Exchanger's Length's Effect in a Thermoacoustic Engine

Potential use of Thermoelectric Generator Device for Air Conditioning System

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

Forced Convection Heat Transfer Enhancement by Porous Pin Fins in Rectangular Channels

CFD Analysis of Forced Convection Flow and Heat Transfer in Semi-Circular Cross-Sectioned Micro-Channel

Research Article. Slip flow and heat transfer through a rarefied nitrogen gas between two coaxial cylinders

Steven W. Van Sciver. Helium Cryogenics. Second Edition. 4) Springer

ScienceDirect. Finite element analysis and optimization of flexure bearing for linear motor compressor

CFD Simulation in Helical Coiled Tubing

CEA Saclay Seminar. Cryogenic Research for HTS Transmission Cables in Korea

An experimental investigation of the thermal performance of an asymmetrical at plate heat pipe

Chapter 1. Introduction

Stresses Analysis of Petroleum Pipe Finite Element under Internal Pressure

USING MULTI-WALL CARBON NANOTUBE (MWCNT) BASED NANOFLUID IN THE HEAT PIPE TO GET BETTER THERMAL PERFORMANCE *

CHAPTER 7 NUMERICAL MODELLING OF A SPIRAL HEAT EXCHANGER USING CFD TECHNIQUE

Simplified Model of WWER-440 Fuel Assembly for ThermoHydraulic Analysis

3D CFD ANALYSIS OF HEAT TRANSFER IN A SCRAPED SURFACE HEAT EXCHANGER FOR BINGHAM FLUIDS

STRUCTURAL ANALYSIS OF A WESTFALL 2800 MIXER, BETA = 0.8 GFS R1. By Kimbal A. Hall, PE. Submitted to: WESTFALL MANUFACTURING COMPANY

CENG 501 Examination Problem: Estimation of Viscosity with a Falling - Cylinder Viscometer

International Journal of Modern Trends in Engineering and Research e-issn No.: , Date: 2-4 July, 2015

Effective Flow And Force Areas Of Discharge Valve In A Rotary Compressor

Simulation of a Thermo-Acoustic Refrigerator

This chapter focuses on the study of the numerical approximation of threedimensional

Experiment (4): Flow measurement

THERMODYNAMICS SSC-JE STAFF SELECTION COMMISSION MECHANICAL ENGINEERING STUDY MATERIAL THERMODYNAMICS THERMODYNAMICS THERMODYNAMICS

FLOW MALDISTRIBUTION IN A SIMPLIFIED PLATE HEAT EXCHANGER MODEL - A Numerical Study

Performance of a Tapered Pulse Tube. 10th International Cryocooler Conference May 26-28,1998 Monterey, CA

Heat Analysis of Liquid piston Compressor for Hydrogen Applications

Influence of Heat Transfer Process in Porous Media with Air Cavity- A CFD Analysis

I. Borsi. EMS SCHOOL ON INDUSTRIAL MATHEMATICS Bedlewo, October 11 18, 2010

NUMERICAL ANALYSIS ON THERMAL ENERGY STORAGE TANK FILLED WITH PHASE CHANGE MATERIAL

Vacuum techniques (down to 1 K)

NOVEL DIAPHRAGM FREE-PISTON STIRLING CRYOCOOLER

JJMIE Jordan Journal of Mechanical and Industrial Engineering

TABLE OF CONTENTS CHAPTER TITLE PAGE

INTRODUCCION AL ANALISIS DE ELEMENTO FINITO (CAE / FEA)

EFFECT OF FORCED ROTATING VANELESS DIFFUSERS ON CENTRIFUGAL COMPRESSOR STAGE PERFORMANCE

Experimental validation of a geometry model for twin screw machines

Theoretical and Experimental Studies on Transient Heat Transfer for Forced Convection Flow of Helium Gas over a Horizontal Cylinder

Characterization of Emitted Vibration from Turbo-Brayton Cryocoolers

Computational study on non-asymptotic behavior of developing turbulent pipe flow

Transcription:

THE IMPACT OF UNCERTAINTIES ASSOCIATED WITH REGENERATOR HYDRODYNAMIC CLOSURE PARAMETERS ON THE PERFORMANCE OF ENERTANCE TUBE PULSE TUBE CRYOCOOLERS J. S. Cha\ S. M. Ghiaasiaan\ C.S. Kirkconnell^, W.M. Clearman\ ^G.W. Woodruff School of Mechanical Engineering Georgia Institute of Technology Atlanta, Ga, 3332, USA ^Raytheon Space Airborne Systems El Segundo, Ca, 9245, USA ABSTRACT Recent investigations have shown that CFD techniques can be applied for modeling the entire pulse tube (PTC) cryocooler systems. However, the results of CFD simulations can be trusted only if they are based on correct closure relations. The hydrodynamic and heat transfer parameters associated with regenerators are among the most important closure relations for these cryocooler systems. In this investigation the impact of uncertainties associated with oscillatory and steady flow resistance parameters on the performance of Inertance Tube Pulse Tube Cryocoolers (ITPTC) is examined using CFD simulations. This objective is achieved by simulations where reference or baseline ITPTCs systems operating in near steady-periodic conditions are modeled in their entirety. Ten transient simulations is performed using oscillatory and steady flow hydrodynamic closure relations corresponding to some of the most widely used regenerator fillers. The effects of uncertainties in the regenerator closure parameters on the cryocoolers performance parameters, as well as their key local hydrodynamic transport processes, are thus quantified. KEYWORDS: CFD Simulation, regenerator, steady, steady-periodic, friction INTRODUCTION The design of Pulse Tube Cryocooler (PTC) systems has advanced incessantly since the invention of basic PTC [1], leading to efficiencies equal to Stirling cryocoolers. The CP985, Advances in Cryogenic Engineering: Transactions of the Cryogenic Engineering Conference CEC, Vol. 53, edited by J. G. Weisend II O 28 American Institute of Physics 978--7354-54-2/8/$23. 243 Downloaded 7 Jun 29 to 74.19.179.18. Redistribution subject to AIP license or copyright; see http://proceedings.aip.org/proceedings/cpcr.jsp

major design variations introduced thus far include the Orifice Pulse Tube Cryocooler (OPTC) [2], double mlet OPTC [3], the modified OPTC [4], the multi-pass OPTC [5], and most recently the Inertance Tube Pulse Tube Cryocooler (ITPTC) [6]. Computational models have been developed for the simulation of regenerator and the entire PTC systems. Among them, Regen 3.2 [7] solves the 1-D time dependent flow and energy conservation equations using the finite difference scheme and predicts the regenerator performance. The well-known computer code Sage [8] is also an essentially 1-D model that can simulate entire OPTC and ITPTC systems in steady-periodic operation. Recent investigations have shown that CFD packages can simulate entire PTC systems [9, 1], capturing multi-d flow effects. However, CFD results can be trusted only if they are based on correct closure relations. The regenerator parameters are among the most important closure relations. In this investigation the impact of uncertainties associated with oscillatory and steady flow resistance parameters on the performance of Inertance Tube Pulse Tube Cryocoolers (ITPTC) is examined. This is done by CFD simulations where reference or baseline ITPTCs systems operating in near steady-periodic conditions are modeled in their entirety. SIMULATED SYSTEMS An ITPTC shown in Figure 1 which includes a compressor, heat exchangers (HXl, CEIX, and ITX2), regenerator, pulse tube, inertance tube, and buffer volume, is simulated using Fluent [11]. All the component dimensions are displayed in Table 1 and Figure 2. The simulated system is identical to the apparatus of Harvey et al. [12], except that the simulated ITPTC includes an inertance tube (IT) and a shorter regenerator (38.1 mm). The test facility of Harvey et al. included an orifice. Buffer Wolume/ Stirling compressor HX2 Pulse Tube CHX Qre«g HXl V Target to be cooled Regenerator TABLE 1. Component radiuses and lengths of ITPTC. Component index A (Compressor) B (Transfer line) C(HXl) D (Regenerator) E(CHX) F (Pulse tube) G(HX2) H (Inertance tube) I (Buffer volume) Radius, r, (mm) 9.54 1.55 4 4 3 2.5 4.425 13 Length, (mm) 7.5 11 2 38.1 5.7 6 1 684.1 13 FIGURE 1. A schematic of ITPTC..r A B C D E F G H I FIGURE 2. Component index of modeled ITPTC system. 244 Downloaded 7 Jun 29 to 74.19.179.18. Redistribution subject to AIP license or copyright; see http://proceedings.aip.org/proceedings/cpcr.jsp

TABLE 2. Boundary and initial conditions and regenerator closure relations for the modeled ITPTCs. ITPTC Model HXl Wall [ K] HX2 Wall [ K] Regenerator Type Regenerator Material AlraY C, [1/m]* Regenerator Porosity CHX, HXl, and HX2 material AK]** C, [1/m]** CHX, HXl and HX2 Porosity Initial CHX Temperature [ K] CHX LOAD (W) 325 mesh 4 mesh 6.4247 67.692.68 Oscillatory friction factor 2.5295 12.692.68 4 mesh sintered 1.9828 11.6147.68 Foam metal 3.7689 66 5547.68 +Micromachined disks Nickel 4. 192.268.68 These values were based on the experiment data of Cha [13] andclearman [14]. + provided by International Mezzo Technologies Inc. Baton Rouge, Louisiana. 325 mesh 42553 47.696.68 Steady friction factor 4 mesh 3.611 7.696.68 4 mesh sintered 1.818 26 6147.68 Foam metal 3.7736 99.5547.68 +Micromachined disks Nickel 43478 115.268.68 ' These values were obtained from Sage Manual [8] Ten simulations were conducted, each for a different set of hydrodynamic regenerator closure relations. The boundary and initial conditions are summarized in Table 2. The PTC boundaries were assumed adiabatic, including the cold heat exchanger (CHX) wall (representing zero cold end cooling load), except for ITXl and HX2 which are listed in Table 2. All the simulations had identical boundary and initial conditions. The regenerator parameters used are based on a separate investigation [13]. The regenerator fillers that are represented are fine wire mesh type (325 and 4 mesh), sinter 4 mesh, metallic foam, and micro-machined disks. Each regenerator filler was represented by two sets of hydrodynamic parameters, one set from steady flow experiments and the other set from an oscillatory (steady-periodic) experiment. These hydrodynamic parameters are summarized in Table 2. Simulations were performed using transient analyses starting from an initial temperature of K and were continued until cycle averaged steady-periodic conditions were reached. CFD MODEL The commercial CFD code Fluent [11] was used. Given the cylindrical and linear alignment of the simulated ITPTC systems, axi-symmetric, two-dimensional flow was assumed. Using a simple user defined function, the piston head motion was modeled as: X Xp sin((»r) ittf (1) 245 Downloaded 7 Jun 29 to 74.19.179.18. Redistribution subject to AIP license or copyright; see http://proceedings.aip.org/proceedings/cpcr.jsp

Compressor Transfer Inertance Tube Buffer Volume HXl Regenerator CHX Pulse Tube ^^^. FIGURE 3. Nodal representation of the simulated ITPTC system. wherexp= 6.5 mm, / = 4 Hz, and the time increment was 5x1 ''seconds. Fluent has a dynamic meshing function that can create deformable mesh volumes. This function was utilized for the compressor. The system was represented by a total of 95 mesh nodes. The mass, momentum and energy equations solved by Fluent for the forthcoming simulations are, respectively: 9 (pw") dt dp dt V. (p M ) = V -(puuy+v P - V (")- pg = (2) (3) (kvt +r-u)- HPjil_ V.(«(p + P))= (4) where P u ' h - + P 2 T = nl{vu + Vu'') V-M/ (5) All properties represent helium. These equations apply to all components except the regenerator and heat exchangers. The regenerator needs to be modeled as a porous medium. The warm and cold-end heat exchangers are also modeled as a porous media for flexibility and generality. When there is local thermodynamic equilibrium between the fluid and solid structure, the mass, momentum, and energy equations in are: 8 i^p ) a t + V (^ep M ) = (6) 9 (^ep u ) + V (^eputi ) + VP + V (er ) = ef,, dt fi -, C p,,,, ^=- u -\ \u \u P 2 I I (7) V i^ekj + (1 - e)k^^t + (T ew)) = {epjej + (1 - e)pfi)^ + V [ez[p^ef + P)) (8) 246 Downloaded 7 Jun 29 to 74.19.179.18. Redistribution subject to AIP license or copyright; see http://proceedings.aip.org/proceedings/cpcr.jsp

where /? [m^] and C [m'] are viscous and inertial resistance coefficient tensors, and U represents the volume-averaged intrinsic (physical) fluid velocity, namely '-\/ RESULTS AND DISCUSSION The cycle average cold-heat exchanger (CEIX) temperatures for oscillatory and steady flow closure parameters are plotted in Figure 4. As expected, gradual cooling was observed at the CHX component for all cases. After 4 seconds of simulation time, the 325 mesh regenerator achieved the lowest cold tip temperature of about \\A K, followed in order by foam metal, 4 mesh, sintered 4 mesh, and the nickel micro-machined disks. Table 3 summarizes the CEIX temperatures for all cases. The cooling rates and differences among the quasi-steady cold tip temperatures depend on the regenerator filler type. The 325 mesh showed the best performance by reaching the lowest cold heat exchanger temperature among and demonstrating the fastest cooling rate. The micro-machined disks (Mezzo regenerator), however, had the least favorable temperature performance among the fillers. The latter result is mainly due to the unfavorable thermophy sical characteristics of nickel r 125 g2 o 15 325 mesh 69% osc ff ---4mesh69%oscff Sintered 4 mesh 69% osc ff Metal foam 55.47% osc ff Micro-machined disks 26.8% osc fi] Sr 125 ><2 o 325mesh69%stdyff ---4mesh69%stdyff Sintered 4 mesh 69% stdyff Metal foam 55.47% stdyff Micro-machined disks 26.8% stdyff 1, 2 4 Time, in [sec] (A) 2 4 6 Time, in [sec] (B) FIGURE 4. Cycle averaged CHX temperatures of simulated ITPTCs using (A) oscillatory flow regenerator closure relations and (B) steady flow regenerator closure relations TABLE 3. Cycle average CHX temperature of simulated ITPTCs. Oscillatory closure relations Regenerator type Transient simulation time (sec) CHX temperature, [ K] 325 mesh 57.6 114.4 4 mesh 59 118. Sinter 4 Micro-machined disks 46.4 42.5 119.5 161 Metal foam 42.4 117.5 Steady closure relations Regenerator type Transient simulation time (sec) 325 mesh 66.5 4 mesh 67.8 Sinter 4 Micro-machined disks 77.8 33.5 Metal foam 34.5 CHX temperature, [ K] 114.5 115.6 117.75 13.5 12.1 247 Downloaded 7 Jun 29 to 74.19.179.18. Redistribution subject to AIP license or copyright; see http://proceedings.aip.org/proceedings/cpcr.jsp

-i Ni micro-machined disk 1 25 2 15-1 CHX HX2 Pulse Tube Regenerator «HXl.2.4.6.8.1.12.14 Direction along component axial [m] FIGURE 5. Temperatures of simulated ITPTC models using oscillatory flow regenerator closure relations. as the filler material. Much better performance would have resulted with stainless. Also, 2 K less cooling occurred at the CHX using oscillatory closure relations instead of steady closure relations for micro-machined disks. The axial distributions of cross-section and cycle-averaged temperatures for 325 mesh and 4 mesh regenerators using oscillatory flow closure relations, under near steady-periodic state, are displayed in Figure 5. Significant temperature gradients are predicted in the regenerator and the pulse tube. These profiles are evidently consistent with the known trends in data. To better understand the performance of the considered systems, simulations were performed and compared with another well defined baseline ITPTC model. The baseline model used was a replica version of the MODI system in [1]. The baseline simulation thus considers an ITPTC that in terms of all physical characteristics is identical to the ITPTC system that was the subject of discussion so far, except for the regenerator length and filler matrix. Also the baseline ITPTC operates at 34 Hz instead of 4 Hz. Results of all the simulations are plotted in Figure 6. Although with exception of the baseline model the simulations have not reached quasi steady-periodic conditions, their trends are clear. 25 2 15-325mesh69%oscfiF 4mesh69%oscfiF Sintered 4 mesh 69% osc ff Metal foam 55.47% oscff -Micro-machined disks 26.8% osc ff baseline 325 mesh 34 Hz HX2Q [-1.8854 W] HXl Q [-63.2772 W] CHX Q [ W] PV[65.1853 W] Energy Imbal [.227 W] 1 5, 1 15 Time, in [sec] (A) Time, in [sec] (B) FIGURE 6. (A) Cycle averaged CHX temperatures of simulated ITPTCs and a baseline model. (B) Energy balance of baseline model. 248 Downloaded 7 Jun 29 to 74.19.179.18. Redistribution subject to AIP license or copyright; see http://proceedings.aip.org/proceedings/cpcr.jsp

*rl C.V a CHX Q. FIGURE 7. Control volume energy balance of baseline ITPTC model. The baseline simulation in Figure 6 has approached the steady periodic operation. The CITX in the baseline system has cooled from K to 92 K in approximately 19 seconds. All others except the simulation for micro-machined disk closely follow the CHX temperature path of the baseline system. The CITX temperatures are all only slightly higher compared to the CHX temperature results of the baseline case. For the model with micromachined disks, the predicted CHX temperature is significantly higher than the baseline model predictions. It appears that once all simulations reach the steady periodic state, their CHX temperatures will be higher than the baseline CHX temperature results. Figure 6 (B) displays the plot of cycle averaged values of the input compressor work, total surface heat rejection rate, and energy imbalance rate for the baseline model. The cycle averaged quantities are defined as: fa)(^dt (9) where ^ is any property. The energy imbalance rate is defined as (Figure 7): p imbalance = Wpv + si. CHX - QHXI - QHX2 (1) As the steady periodic operation is approached, the energy imbalance term in Eq. (1) should asymptotically approach zero. According to figure 6 (B) the energy conservation is nearly satisfied. The energy imbalance for the baseline simulations was only.227 W after 19 seconds. CONCLUSION The impact of uncertainties associated with oscillatory and steady flow resistance parameters on the performance an ITPTC was examined using CFD simulations. Parametric simulations were performed to compare the overall thermal performance of the tested regenerator fillers under oscillatory flow conditions. The 325 mesh regenerator had the best system level performance among all simulated regenerator fillers. The nickel micro-machined disks regenerator filler had the worst thermal performance. The poor performance of the micro-machined disks was mainly due to the inferior thermal properties of nickel as a regenerator filler material, as compared to stainless steel. If stainless steel were to be used instead of nickel, the thermal performance of the micro machined disks would be much improved. The results also showed that the regenerator having the lowest friction factor does not necessarily produce the best system level thermal performance. ACKNOWLEDGEMENTS 249 Downloaded 7 Jun 29 to 74.19.179.18. Redistribution subject to AIP license or copyright; see http://proceedings.aip.org/proceedings/cpcr.jsp

The authors gratefuuy thank Drs. Jeremy Harvey and Prateen Dasai for technical assistance and Raytheon Company for the financial support. NOTATION C = Inertial resistance coefficient tensor f = Friction factor [-], frequency [Hz] h = Enthalpy T = Unit identity tensor k = Thermal Conductivity P = Static pressure T = Temperature X= Compressor piston displacement u = Intrinsic Velocity Greek letters P = Viscous resistance coefficient tensor S = Porosity Tensors /J = Viscosity p = Density r = Newtonian shear stress Subscripts / = Fluid r, X = Radial and Axial coordinate s= Solid Superscripts T = Transpose REFERENCES 1. 13. 14. Gifford, W.E. and Longthworth, R.C., "Pulse-Tube Refrigeration," Trans. ASME, J. Eng. Ind. (series B), 86 (1964), pp. 264-268. Mikulin, E.I., Tarasov, A.A., and Shrebyonock, M.P., "Low-temperature expansion pulse tubes". Advances in Cryogenics Engineering, vol 29, pp. 629-637. Zhu, S.W., Wu, P.Y., and Chen, Z.Q., " A single stage double inlet pulse tube refrigerator capable of reaching 42K", ICEC 13 Proc. Cryogenics, 3 (199), pp.256-261. Wang, C, Wu, P., and Chen, Z., "Modified orifice pulse tube refrigerator without a reservoir". Cryogenics, 34 (1994), pp. 31-36. Cai, J.H., Wang, J. J., Zhu, W.X. and Zhou, Y., "Experimental analysis of double-inlet principle in pulse tube refrigerator". Cryogenics, 33 (1993), pp. 522-525. Zhu, S.W., Zhou, S.L., Yoshimura, N., and Matsubara, Y., "Phase shift effect of the long neck tube for the pulse tube refrigerator", Proc. 9* IntT Cryocoolers Conf, June 1996, p. 269. Gary, J. O'Gallagher, A. and Radebaugh, R. 1994. A Numerical Model for Regenerator Performance, Technical Report, NIST-Boulder. Gedeon, D., Pulse Tube Model-Class Reference Guide, Gedeon Associates (1999). Hozumi, Y., Shiraishi, M., and Murakami, M., "Simulation of thermodynamics aspects about pulse tube refrigerator", presented in ICEC 9/23, Anchorage Alaska. Cha, J. S. 24. CFD Simulations of Multi-Dimensional Effects in an Inertance Tube Pulse Tube Cryocoolers. Masters Thesis, Georgia Institute of Technology, Atlanta, Ga. Fluent INC. Fluent 6 User Manual pp. 8-1. Fluent INC, 23. Harvey, J.P. 1999. Parametric study ofcryocooler regenerator performance, M.S. Thesis, Georgia Institute of Technology, Atlanta, GA. Cha, J. S. 27. Hydrodynamic Parameters of Micro-Porous Media for Steady and Oscillatory Flow: Application to Cryocooler Regenerators. PhD Thesis. Georgia Institute of Technology, Atlanta, Ga. Clearman W. 27. Measurement and Correlation of Directional Permeability and Forchheimer's inertial Coefficient of Micro Porous Structures Used in Pulse-Tube Cryocoolers. Masters Thesis. Georgia Institute of Technology, Atlanta, Ga. 25 Downloaded 7 Jun 29 to 74.19.179.18. Redistribution subject to AIP license or copyright; see http://proceedings.aip.org/proceedings/cpcr.jsp