International Journal of Innovative Research in Science, Engineering and Technology

Similar documents
SSRG International Journal of Mechanical Engineering ( SSRG IJME ) Volume 2 Issue 5 May 2015

Heat Transfer Enhancement with Different Square Jagged Twisted Tapes and CuO Nano fluid

Analysis of Heat Transfer in Pipe with Twisted Tape Inserts

Enhancement of Heat Transfer in Heat Exchanger using Punched and V-cut Twisted Tape Inserts

Experimental and Numerical Analysis of Turbulent Flow Heat Transfer Enhancement in a Horizontal Circular Tube Using Mesh Inserts

Department of Mechanical Engineering, VTU, Basveshwar Engineering college, Bagalkot, Karnataka, India

Performance analysis of V-jagged twisted tape insert for heat transfer in a circular tube

Experimental Investigation of Heat Transfer Enhancement by Using Clockwise and Counter -clockwise Corrugated Twisted Tape Inserts

Heat Augmentation Using Non-metallic Flow Divider Type Inserts in Forced Convection

Research Article. Kaustubh G. Kulkarni * and Mandar M. Lele. Abstract

International Journal of Advanced Engineering Research and Studies E-ISSN

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 06, 2015 ISSN (online):

AUGMENTATION OF HEAT TRANSFER USING COILED POROUS TWISTED TAPE INSERT

Australian Journal of Basic and Applied Sciences. Heat transfer enhancement of laminar flow in a circular tube using Swirl / vortex generator

EFFECT OF BAFFLES GEOMETRY ON HEAT TRANSFER ENHANCEMENT INSIDE CORRUGATED DUCT

Exergy Analysis of Solar Air Collector Having W Shaped Artificial Roughness

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

NUMERICAL HEAT TRANSFER ENHANCEMENT IN SQUARE DUCT WITH INTERNAL RIB

Experimental Heat transfer study of Turbulent Square duct flow through V type turbulators

COMPUTATIONAL FLUID DYNAMICS ANALYSIS OF A V-RIB WITH GAP ROUGHENED SOLAR AIR HEATER

Investigation of Heat Transfer on Smooth and Enhanced Tube in Heat Exchanger

Sami D. Salman, 1,2 Abdul Amir H. Kadhum, 1 Mohd S. Takriff, 1 and Abu Bakar Mohamad Introduction

Investigation of Heat Transfer Enhancement in Laminar Flow through Circular Tube Combined Wire Coil and Wavy Strip with Central Clearance

Heat Transfer Enhancement Using a Rotating Twisted Tape Insert

Experimental Investigation of Heat Transfer Enhancement with Different Square Jagged Twisted Tapes and CuO/water Nano fluid

HEAT TRANSFER ENHANCEMENT WITH ELLIPTICAL TUBE UNDER TURBULENT FLOW TiO 2 -WATER NANOFLUID

Chapter 3 NATURAL CONVECTION

Heat Transfer Enhancement of Shell and Tube Heat Exchanger Using Conical Tapes.

Effect of V-Shape Twisted Jaw Turbulators on Thermal Performance of Tube heat exchanger: An Experimental Study

Numerical Analysis of Fe 3 O 4 Nanofluid Flow in a Double Pipe U-Bend Heat Exchanger

EFFECT OF STAGGERED RIB LENGTH ON PERFORMANCE OF SOLAR AIR HEATER USING V-RIB WITH SYMMETRICAL GAP AND STAGGERED RIB

Numerical investigation of heat transfer enhancement in a pipe heat exchanger by adding nano particle and twisted tape

International Journal of Emerging Technologies in Engineering Research (IJETER)

Experimental Validation of Heat Transfer Enhancement in plate Heat Exchanger with Non Conventional Shapes of Rib

A Computational Fluid Dynamics Investigation of Solar Air Heater Duct Provided with Inclined Circular Ribs as Artificial Roughness

CFD Analysis on Flow Through Plate Fin Heat Exchangers with Perforations

Thermo-Hydraulic Performance of a Roughened Square Duct Having Inclined Ribs with a Gap on Two Opposite Walls

Heat Transfer Enhancement in Fe3O4-water Nanofluid through a Finned Tube Counter Flow Heat Exchanger

Analysis, Design and Fabrication of Forced Convection Apparatus

Computational Analysis of Heat Transfer Enhancement in a Circular Tube Fitted with Different Inserts

Sarbendu Roy, Manvendra Tiwari and Sujoy Kumar Saha 1. Mechanical Engineering Department, IIEST, Shibpur, Howrah , West Bengal, INDIA

Comparative Analysis of Heat Transfer and Friction Characteristics in a Corrugated Tube

Heat transfer characteristics and friction of turbulent swirling air flow through abrupt expansion

International Journal of Advanced Engineering Technology E-ISSN

EFFECT OF TWISTED TAPE INSERTS IN DOUBLE PIPE HEAT EXCHANGER USING AL2O3/WATER NANO FLUIDS

Performance evaluation of heat transfer enhancement for internal flow based on exergy analysis. S.A. Abdel-Moneim and R.K. Ali*

CFD Investigation of Heat Transfer and Flow Patterns in Tube Side Laminar Flow and the Potential for Enhancement

HEAT TRANSFER ENHANCEMENT IN HEAT EXCHANGER USING TANGENTIAL INJECTOR TYPE SWIRL GENERATOR

Internal Forced Convection. Copyright The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

Australian Journal of Basic and Applied Sciences

EXPERIMENTAL STUDIES ON HEAT TRANSFER AUGMENATATION USING GALVANISED IRON WIRE INSERT WITH AND WITHOUT BAFFLES

The Effect of Solid and Perforated Pin Fin on the Heat Transfer Performance of Finned Tube Heat Exchanger

International Journal of Mechanical & Mechatronics Engineering IJMME-IJENS Vol:18 No:02 1

International Journal of Scientific & Engineering Research, Volume 5, Issue 11, November ISSN

Numerical Heat Transfer Study of Turbulent Square Duct Flow through W-Type Turbulators

Heat Transfer Analysis of Helical Strip Insert with Regularly Spaced Cut Sections Placed Inside a Circular Pipe

Enhancement in the Performance of Heat Exchanger by Inserting Twisted Tape Turbulators

INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY

Heat Transfer Predictions for Carbon Dioxide in Boiling Through Fundamental Modelling Implementing a Combination of Nusselt Number Correlations

HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF COMPOUND TURBULATORS IN RECTANGULAR DUCTS OF SOLAR AIR HEATER

Experimental studies on hydrodynamic behaviour of flow through a tube with TRIANGULAR WAVY TAPES. Bachelor of Technology in Chemical Engineering

Thermo-Hydraulic performance of Internal finned tube Automobile Radiator

Experimental Investigation of Trapezoidal Duct using Delta Wing Vortex Generators

Convective Heat Transfer and Thermal Performance in a Circular Tube Heat Exchanger Inserted with U-Shaped Baffle

Cfd Simulation and Experimentalverification of Air Flow through Heated Pipe

EXPERIMENTAL STUDIES ON HEAT TRANSFER AUGMENTATION USING TRIANGULAR WAVY TAPE (TWT) AS INSERTS FOR TUBE SIDE FLOW OF LIQUIDS

Experimental Investigation of Forced Convection Heat Transfer Augmentation from a Dimpled Surface

Forced Convection Heat Transfer in the Entrance Region of Horizontal Tube under Constant Heat Flux

CHAPTER 3 SHELL AND TUBE HEAT EXCHANGER

INTERNATIONAL JOURNAL OF SCIENTIFIC & TECHNOLOGY RESEARCH VOLUME 5, ISSUE 09, SEPTEMBER 2016 ISSN

International Journal of Engineering, Business and Enterprise Applications (IJEBEA)

CFD Analysis of Forced Convection Flow and Heat Transfer in Semi-Circular Cross-Sectioned Micro-Channel

Effectiveness and Overall Heat Transfer Coefficient of Fe 3 O 4 /Water Nanofluid Flow in a Double Pipe Heat Exchanger with Return Bend

Heat Transfer F12-ENG Lab #4 Forced convection School of Engineering, UC Merced.

This is the author s final accepted version.

Experimental Analysis of Rectangular Fin Arrays with Continuous Fin and Interrupted Fins Using Natural and Forced Convection

COMPUTATIONAL FLUID DYNAMICS ANALYSIS ON HEAT TRANSFER AND FRICTION FACTOR CHARACTERISTICS OF A TURBULENT FLOW FOR INTERNALLY GROOVED TUBES

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

Amir Houshmand, Ahmad Sedaghat, Kia Golmohamadi and Mohamadreza Salimpour

EXPERIMENTAL AND CFD ANALYSIS OF TURBULENT FLOW HEAT TRANSFER IN TUBULAR HEAT EXCHANGER

EXPERIMENTAL AND CFD ANALYSIS OF TURBULENT FLOW HEAT TRANSFER IN TUBULAR EXCHANGER

ME 331 Homework Assignment #6

CFD analysis of CuO/water nanofluid flow in a double pipe U-Bend heat exchanger

International Communications in Heat and Mass Transfer

Experimental Analysis of Heat Transfer Enhancement through Pipe using Baffles

Experimental Investigation of Trapezoidal Duct using Delta Wing Vortex Generators

Numerical Investigation of Heat Transfer Enhancement and Pressure Drop of a Double Tube Heat Exchanger with Rectangular Fins in the Annulus Side

Flow and Heat Transfer Profiles in a Square Channel with 45 V-Downstream Orifices

Computational Fluid Dynamics Based Analysis of Angled Rib Roughened Solar Air Heater Duct

Comparative study of Different Geometry of Ribs for roughness on absorber plate of Solar Air Heater -A Review

Department of Mechanical Engineering, M.A.C.T. (R.E.C.), Bhopal , India b. Received 15 December 2000; accepted 15 January 2001

Natural Convection from a Long Horizontal Cylinder

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 2, No 1, 2011

Practical Analysis Of Turbulent Flow In A Pipe Using Computational Fluid Dynamics

Estimation of Heat Transfer in Internally Micro Finned Tube

Mechanism of Heat Transfer Enhancement in the Core Flow of a Tube and Its Numerical Simulation

Augmented Heat Transfer in Square ducts with Transverse and Inclined Ribs with and without a gap

HEAT TRANSFER CAPABILITY OF A THERMOSYPHON HEAT TRANSPORT DEVICE WITH EXPERIMENTAL AND CFD STUDIES

Heat Transfer Coefficient Solver for a Triple Concentric-tube Heat Exchanger in Transition Regime

EVALUATION OF THERMAL PERFORMANCE OF CONE SHAPED HELICAL COIL HEAT EXCHANGER BY USING CFD ANALYSIS

Transcription:

ISSN(Online): 2319-8753 Heat Transfer Intensification in U-bend Double Pipe Heat Exchanger using Twisted Tape Inserts L.Sandeep Raj 1, K.Vijaya Kumar Reddy 2, A.Aruna Kumari 2 Assitant Professor, VNR Vignana Jyothi Institute of, Hyderabad, India 1 Professor, JNTUH College of Engineering Hyderabad, India 2 Abstract: Generating a swirl flow in the flow field is widely employed passive heat transfer augmentation or intensification technique. In present work, twisted tapes are inserted into the inner pipe side of Counter flow U-bend Double Pipe Heat Exchanger for creating a swirl flow and thus Enhancing the Heat Transfer. Twisted tapes of different twist ratios (H/D) 5,10,15,20 and strip insert (i.e without any twist) are employed to enhance the Heat Transfer. Turbulent swirl flow with forced convection is considered for experimental study. For different twist ratios, mass flow rate of cold fluid in inner pipe side is varied, by maintaining the constant mass flow rate in the annulus side. Experimental data is validated using available correlations. The results show that, for mass flow rate of 8 LPM the enhancement in Heat Transfer is 55.69% compared with that of plain tube and corresponding Pressure Drop is only 20%. Keywords: Heat Transfer Intensification, Heat Transfer Enhancement, U-bend Double Pipe Heat Exchanger, Inserts, Twisted Tapes. I. INTRODUCTION Heat Transfer is unavoidable process that nature has gifted to Humankind. In engineering applications wherever energy conversion is involved, Heat transfer finds a great importance. Heat Transfer Enhancement or Intensification aims at increasing the rate at which Heat transfers from one body to another or from one medium to another. Improved Heat Exchange over and above the usual and standard practice can significantly improve thermal efficiency in such engineering applications as well as the economics of their design and operation can be optimised [1]. This fact gives lot of scope for Research in this area of Heat Transfer Enhancement. S.S. Hsieh, I.W. Huang[2] investigated Heat Transfer Enhancement in Laminar Flow with Longitudinal inserts. For these inserts, Thermal Entry Length was found and it is correlated with in terms of Reynolds Number. Based on same hydraulic Diameter, Enhancement of Heat Transfer compared to bare tube was found to be 16 times more at Reynolds Number less than 400, while Friction Factor rise is just 4.5 times. S. K. Saha, A. Dutta[3] observed that for higher twists, twisted tapes of short length are performing better than full length twisted tapes. Lower values of Nusselt Number and Friction Factor are obtained for short length twisted tapes compared with full length counter parts. Under Uniform Wall Heat Flux boundary condition, S. K. Saha, P. Langille[4] conducted experimental and theoretical studies on Laminar flow through a circular tube. For short length strips & regularly spaced strip elements, Friction Factor & Nusselt Number are less in comparison with the full length elements Anil Singh Yadav[5] found that heat transfer coefficient is found to increase by 40% with half-length twisted tape inserts when compared with plain heat exchanger. It was found that on the basis of equal mass flow rate, the heat Copyright to IJIRSET DOI:10.15680/IJIRSET.2015.0502001 1333

ISSN(Online): 2319-8753 transfer performance of half-length twisted tape is better than plain heat exchanger, and on the basis of unit pressure drop the heat transfer performance of smooth tube is better than half-length twisted tape. P. V. Durga Prasad, A. V. S. S. K. S. Gupta[6] reported that on equal mass flow rate basis, Heat Transfer performance is enhanced with twisted tapes. Whereas, on unit pressure drop basis, Heat Transfer performance is better on smooth tube compared with twisted tapes. They also reported significant increase in heat transfer coefficient, friction factor, and found that the thermal Performance of smooth tube is better than the full length twisted tape by 2.0 2.2 times. Based on experimental flow visualization and computational modelling of single-phase laminar flows, Raj M. Manglik, Arthur E. Bergles[7] considered a fundamental scaling of the cross-sectional vortex structure and a parametric analysis of the primary enhancement mechanisms in single-phase flows are delineated. B. V. N. Ramakumar, J. D. Arsha, Praveen Tayal[8] employed Tapered Twisted Tape Inserts for Enhancing Heat Transfer. They performed simulations using ANSYS FLUENT 14.0. They reported that overall enhancement ratio is greater than that of classical twisted tapes under all Reynolds Number Studied. An increase of 17% in overall enhancement is predicted with taper angle of 0.5. S.N. Sarada, A.V.S.R. Raju and K.K. Radha[9] conducted experimental and theoretical studies on turbulent flow heat transfer enhancement in a horizontal circular tube using mesh inserts. They reported an increase of Nusselt number 2.15 times and pressure drop of only 1.23 times compared to that of plain tube. P.Murugesan, K.Mayilsamy, S.Suresh[10] investigated Heat Transfer Enhancement using square cut twisted tapes with three twist ratios 2.0, 4.4, 6.0. Over the range considered, the Nusselt number is 1.03 to 1.14 times, friction factor is 1.05 to 1.25 times and thermal enhancement factor is 1.02 to 1.06 times in a tube with Square cut Twisted Tape of those in tube with Plain Twisted Tapes. Twin counter twisted tapes and twin co-twisted tapes are employed by S. Eiamsa-ard, C. Thianpong, P. Eiamsaard[11] for generating counter swirl flow and co-swirl flow respectively. They reported that Twin counter twisted tapes improve Heat Transfer around 12.5 44.5% and 17.8 50% higher than those with the twin co-twisted tapes and single twisted tape, respectively. S. V. Patil & P. V. Vijay Babu[12] employed twisted tapes in square Duct and Circular Tube. Working Fluid is Ehylene Glycol. Based on constant flow rate and constant pumping power criteria, Nusselt numbers were found to be 5.44 7.49 and 2.46 4.87 times that of plain square duct forced convection values respectively. Numerical Simulation Studies are conducted by Sami D. Salman, Abdul Amir H. Kadhum, Mohd S. Takriff, Abu Bakar Mohamad[13] on Circular Tube Fitted with Alternative Axis Twisted Tape under a Constant Heat Flux. Among the various twist ratios and alternative angles, the twist ratio of y = 2.93 and alternative angle β = 90 offered a maximum heat transfer enhancement. II. EXPERIMENTAL SETUP AND PROCEDURE 2.1 Description of Experimental Setup: The Counter Flow U-bend Double Pipe Heat Exchanger considered for this Experimental study consists of two essential parts 1. Inner Pipe of Inner Diameter(d i ) =19mm, Outer Diameter (d 0 ) = 25mm 2. Outer Pipe of Inner Diameter (Di) = 50mm, Outer Diameter (Do) = 56mm Both these Pipes are mounted concentrically as shown in the Figure 1. Outer pipe is insulated using an asbestos sheet throughout its length. Inner pipe which is not covered by annulus is also insulated with asbestos sheet. Copyright to IJIRSET DOI:10.15680/IJIRSET.2015.0502001 1334

ISSN(Online): 2319-8753 Figure1: Dimensions of U-Bend Double Pipe Heat Exchanger. Experimental setup primarily comprises of two circuits. 1. Cold Water Circuit 2. Hot Water Circuit In Cold Water Circuit, indicated with green colour in Figure 1 and Figure 2, the cold water in the cold water stainless steel tank is pressurised using 0.5HP Motor Pump. At the exit of the Pump, the cold water is allowed to flow through a Rotameter, which is used for regulating the Discharge or Rate of Flow. Then water is made to enter the inner pipe side of Heat Exchanger. At exit, cold water is drained. In this cold water circuit, two k- type thermocouples are placed at the inlet and outlet of inner pipe of Heat Exchanger, which are used for indicating the temperatures in the separately connected Digital meter. Inlet and outlet of the inner pipe are connected to a U-Tube Mercury Manometer for measuring Pressure Drop. In Hot Water Circuit, indicated with green colour in Figure 1 and Figure 2, the water in the insulated stainless steel tank is heated using a 0.375kW Heater. After obtaining the required hot water temperature, the hot water is pressurised using a 0.5HP Motor Pump. At the exit of the pump, a Rotameter is arranged for regulating the Discharge or Rate of Flow. Then the water is made to flow through the annulus of the Heat Exchanger. In this Hot water circuit also, two k- type thermocouples are placed at the inlet and outlet of Annulus of Heat Exchanger, which are used for indicating the temperatures in the separately connected Digital meter. Figure2: Experimental Setup of Counter flow U-bend Double Pipe Heat Exchanger. Copyright to IJIRSET DOI:10.15680/IJIRSET.2015.0502001 1335

ISSN(Online): 2319-8753 2.2 Twisted Tape Geometry: Figure 3: Geometry of Twisted Tape insert. The Geometrical features of the twisted tape insert are represented in Figure 3. A aluminium strip of 1mm thickness is twisted into required twist ratios. Here H represents the pitch of Twisted Tape and D represents the width of Twisted Tape, measured across diameter. Table1 shows the Dimensions of Twisted Tapes with Different Geometries. H/D ratio is used to name each twisted tape insert. Table 1: Dimensions of Twisted Tape Insert. H/D Ratio H (in meter) D (in meter) 5 0.09 0.018 10 0.18 0.018 15 0.27 0.018 20 0.36 0.018 2.3 Experimental Procedure: Initially experiments are conducted on plain tube i.e without any insert. At the beginning of every experiment, the flow rates of cold water and hot water are set at required rates using Rotameter. For all experiments, the cold water flow rate is fixed at 8LPM. The Hot water flow rate is varied from 8LPM to 12LPM for the different experiments. After heating the water in insulated Hot water tank to the required temperature, the hot water is made to flow through the annulus. Simultaneously, the cold water is made to flow through the inner pipe. Steady state is reached in 20 to 30 minutes of time. After reaching Steady State, the temperatures are recorded. Difference of heights of mercury in Manometer is also recorded. Twisted tape insert of 2m length is inserted into the inner pipe of Heat Exchanger such that it covers the length of annulus and same experimental procedure is followed. III. DATA REDUCTION PROCEDURE Heat transfer on annulus side i.e on hot water side is calculated using Q h =ṁ h *C ph *ΔT h (1) Heat transfer on inner pipe side i.e on cold water side is calculated using Q c =ṁ c *C pc *ΔT c (2) Average Heat Transfer is calculated using Q avg =(Q h +Q c )/2 (3) Reynolds number is calculated using Re=v*D e /ⱴ (4) where Kinematic Viscosity ⱴ is measured at Bulk Mean Temperature. Nusselt Number on Hot water Annulus side is calculated from Dittus Boelter Equation Nu=0.023*(Re) 0.8 *(Pr) 0.3 (5) Heat Transfer Coefficient is measured from Copyright to IJIRSET DOI:10.15680/IJIRSET.2015.0502001 1336

h (W/m 2 K) ISSN(Online): 2319-8753 h annulus =Nu*k/D e (6) where Thermal Conductivity k is measured at Bulk Mean Temperature. Overall Heat Transfer Coefficient is measured from U=Q avg /(A avg *LMTD) (7) Experimental Heat Transfer Coefficient is measured from h exp =1/((1/U)-(1/h annulus )) (8) Friction Factor is Calculated from f = (2*ΔP*D i )/(ρ*l*v 2 ) (9) 4.1 Validation of Plain Tube Data: 4.1.1.Heat Transfer: Available correlations for plain tube are 1. Dittus Boelter Equation[15] IV. DISCUSSION ON RESULTS 2. Petukhov Equation[15] 3. Gnielinski Equation[15] Nu = 0.023.(Re) 0.8.(Pr) 0.3 { 0.7 Pr 160;Re > 10,000} ( ) ( ) ( ) 0.5 Pr 2000 10 4 Re 5 x 10 6 ( ) ( ) ( ) ( ) 0.5 Pr 2000 3 x 10 3 Re 5 x 10 6 h Vs m c 4500 4000 3500 3000 2500 dittus boelter petukhov Gnielinski experimental 2000 7 8 9 10 11 12 13 m c (LPM) Figure 4: Comparison of present experimental Heat Transfer data with available correlations. Copyright to IJIRSET DOI:10.15680/IJIRSET.2015.0502001 1337

f ISSN(Online): 2319-8753 In Figure 4, the value of h, Heat Transfer Coefficient obtained in experiment is compared with the available correlations given by Dittus Boelter, Petukhov, Gnielinski. From this it has been observed that the experimental Heat transfer coefficient is in agreement with available correlations. 4.1.2. Friction Factor Available correlations for plain tube are 1. Blasius Equation[15] 2. Petukhov Equation[15] 3. Simple Power Law Equation[15] ( ( ) ) 3000 Re 5 x 106 0.045 0.04 0.035 0.03 0.025 Blasius Petukhov Simple Power Law experimental 0.02 0.015 10000 12000 14000 16000 18000 Figure 5: Comparison of present experimental friction factor with available correlations. In Figure 5, the value of f, friction factor obtained in experiment is compared with the available correlations Blasius Equation, Petukhov Equation, Simple Power Law Equation. From this figure it is observed that the experimental friction factor is in agreement with available correlations 4.2 Validation of Twisted Tape Data: Available Nusselt Number correlations for twisted tapes are 1. Sarma et.al Correlation Nu = 0.1012(1+(D/H)) 2.065 (Re) 0.67 (Pr) 0.3 2. Manglik and Bergles Correlation[16] Re Nu = 0.023 Re 0.8 Pr 0.4 (1+(0.769(2D/H))) Where, [ ] [ ] Copyright to IJIRSET DOI:10.15680/IJIRSET.2015.0502001 1338

h (W/m 2 K) h (W/m 2 K) ISSN(Online): 2319-8753 a) H/D 5 h Vs m c 8000 7000 6000 5000 4000 3000 plain tube h/d5 sarma et.al h/d5 manglik and bergles h/d5 experimental 2000 7 9 11 13 m c (LPM) Figure 6: Comparison of experimental heat transfer coefficient with available correlations-twisted tape insert H/D5. In Figure 6, the value of h, Heat Transfer Coefficient obtained in experiment is compared with the available correlations given by Sarma et.al and Manglik & Bergles. In this Plot, it has been observed that the experimental Heat transfer coefficient is in agreement with available correlations with considerable maximum variation of +8%. When twisted tape insert of twist ratio H/D 5 is used, Compared with Plain Tube, Highest Heat Transfer Enhancement of 55.69% is observed at 12LPM (Re=16988). Corresponding Pressure Drop is 20%, Compared with Plain Tube. b) H/D 10 h Vs m c 5500 5000 4500 4000 3500 3000 2500 7 9 11 13 m c (LPM) plain tube h/d10 sarma et.al h/d10 manglik and bergles h/d10 experimental Figure 7: Comparison of experimental heat transfer coefficient with available correlations-twisted tape insert H/D 10. In Figure 7, the value of h, Heat Transfer Coefficient obtained in experiment is compared with the available correlations given by Sarma et.al and Manglik & Bergles. In this Plot, it has been observed that the experimental Heat transfer coefficient is in agreement with available correlations with considerable maximum variation of +4%. When twisted tape insert of twist ratio H/D 10 is used, Compared with Plain Tube, Highest Heat Transfer Enhancement of 38% is observed at 12LPM (Re=16988). Corresponding Pressure Drop is 23%, Compared with Plain Tube. Copyright to IJIRSET DOI:10.15680/IJIRSET.2015.0502001 1339

h (W/m2K) h (W/m 2 K) ISSN(Online): 2319-8753 c) H/D 15 5500 5000 4500 4000 3500 3000 2500 7 8 9 10 11 12 13 m c (LPM) h Vs m c plain tube h/d15 sarma et.al h/d15 manglik and bergles h/d15 experimental Figure 8: Comparison of experimental heat transfer coefficient with available correlations-twisted tape insert H/D 15. In Figure 8, the value of h, Heat Transfer Coefficient obtained in experiment is compared with the correlations given by Sarma et.al and Manglik & Bergles. In this Plot, it has been observed that the experimental Heat transfer coefficient is in agreement with available correlations with considerable maximum variation of +9%. When twisted tape insert of twist ratio H/D 10 is used, Compared with Plain Tube, Highest Heat Transfer Enhancement of 24.8% is observed at 12LPM (Re=17026). Corresponding Pressure Drop is 26.66%, Compared with Plain Tube. d) H/D 20 5500 5000 h Vs mc 4500 4000 3500 3000 plain tube h/d20 sarma et.al h/d20 manglik and bergles h/d20 experimental 2500 7 8 9 10 11 12 13 mc (LPM) Figure 9: Comparison of experimental heat transfer coefficient with available correlations-twisted tape insert H/D 20. In Figure 9, the value of h, Heat Transfer Coefficient obtained in experiment is compared with the correlations given by Sarma et.al and Manglik & Bergles. In this Plot, it has been observed that the experimental Heat transfer coefficient is in agreement with available correlations with considerable maximum variation of -9%. When twisted tape Copyright to IJIRSET DOI:10.15680/IJIRSET.2015.0502001 1340

h (W/m2K) ISSN(Online): 2319-8753 insert of twist ratio H/D 10 is used, Compared with Plain Tube, Highest Heat Transfer Enhancement of 16.4% is observed at 12LPM (Re=17677). Corresponding Pressure Drop is 30%, Compared with Plain Tube. e) Strip Insert (without any twist) 5500 5000 h Vs mc 4500 4000 3500 3000 plain tube strip sarma et.al strip manglik and berles strip experimental 2500 7 8 9 10 11 12 13 mc (LPM) Figure 10: Comparison of experimental heat transfer coefficient with available correlations for strip insert. In Figure 10, the value of h, Heat Transfer Coefficient obtained in experiment is compared with the correlations given by Sarma et.al and Manglik & Bergles. In this Plot, it has been observed that the experimental Heat transfer coefficient is in agreement with available correlations with maximum variation of -13%. When twisted tape insert of twist ratio H/D 10 is used, compared with Plain Tube, Highest Heat Transfer Enhancement of 8% is observed at 12LPM (Re=17677). Corresponding Pressure Drop is 36%, Compared with Plain Tube. 4.2.1 Effect of Twist Ratio on Heat Transfer Enhancement Twist Ratio has significant effect on the amount of Heat Transfer Enhancement. From experiments it has been observed that more is the twist i.e lesser the Twist Ratio, Higher is the Heat Transfer Enhancement. Further it is observed that negative effect of Pressure Drop is reduced significantly at Higher Twists and Lower Twist Ratios. 4.2.2 Mass Flow Rate based Analysis At Cold Water mass flow rate of 12LPM, it has been observed that the highest Heat Transfer Enhancement is achieved in all cases. Also, it is observed that Heat Transfer Enhancement increases with increase of Mass Flow Rate. This mass flow rate refers to Reynolds Number in Non Dimensional Similarity Analysis. Higher is the Reynolds Number, Higher is the Heat Transfer Enhancement. Also we may conclude that Highly Turbulent Flow Fields have Higher chances of Heat Transfer Enhancement, in the range considered for Experiments. 4.3 Pressure Drop with inserts Copyright to IJIRSET DOI:10.15680/IJIRSET.2015.0502001 1341

ΔP( PASCAL) ISSN(Online): 2319-8753 2500 2000 1500 1000 500 plain tube h/d5 h/d10 h/d15 h/d20 strip 0 7 8 9 10 11 12 13 MASS FLOW RATE ON COLD SIDE (LPM) Figure 11: Variation of Pressure Drop for all Inserts. It has been observed from Figure 11, that the Pressure Drop is also increasing with increase in mass flow rate. But the Negative Effect of this increased Pressure Drop can be compromised with higher Heat Transfer Enhancement at Higher Twists i.e at Lower Twist Ratios. V. CONCLUSION The following conclusions are drawn from the experimental investigations carried out in the Counter flow U-bend Double Pipe Heat Exchanger by the means of strip and twisted tape inserts. From experiments it is observed that enhancement of heat transfer is maximum when twisted tape insert with H/D ratio= 5 is used. Also it is observed that more is the twist or the swirl of the insert, more is the Heat transfer Enhancement. Enhanced Heat Transfer obtained is 55.696% with insert of H/D ratio =5 at 12LPM and Re = 16,988 compared with that of plain tube and corresponding Pressure Drop is only 20%. Swirl motion is primarily responsible for the Enhancement of Heat Transfer, it is obvious from the fact that more is the twist ratio, more is the Enhancement. Acknowledgement Corresponding Author gratefully acknowledges the warm and kind support of Dr.A.V.S.S.K.S.Gupta, Professor, JNTUHCEH & Dr.P.Bhramara, Associate Professor, JNTUHCEH during this research work. REFERENCES [1] RM Manglik, Chapter 14 Heat Transfer Handbook, Volume 1 By Adrian Bejan, Allan D. Kraus John Wiley and Sons 2003 [2] S.-S. Hsieh, I.-W. Huang Heat Transfer and Pressure Drop of Laminar Flow in Horizontal Tubes With/Without Longitudinal Inserts ASME J. Heat Transfer. 1999; 122(3):465-475 [3] S. K. Saha, A. Dutta Thermohydraulic Study of Laminar Swirl Flow Through a Circular Tube Fitted With Twisted Tapes ASME J. Heat Transfer. 2001; 123(3): 417-427. [4] S. K. Saha, P. Langille Heat Transfer and Pressure Drop Characteristics of Laminar Flow Through a Circular Tube With Longitudinal Strip Inserts Under Uniform Wall Heat Flux ASME J. Heat Transfer. 2002; 124(3):421-432. [5] Anil Singh Yadav Effect of half length twisted tape turbulator on heat transfer & pressure drop characteristics inside a double pipe U-bend heat exchanger Jordan journal of Mech. & Industrial engg., Vol. 3 No.1 (2009), pp. 17-22. Copyright to IJIRSET DOI:10.15680/IJIRSET.2015.0502001 1342

ISSN(Online): 2319-8753 [6] P. V. Durga Prasad A. V. S. S. K. S. Gupta Augmentation of Heat Transfer and Pressure Drop Characteristics Inside a Double Pipe U-Tube Heat Exchanger by Using Twisted Tape Insert Journal of Emerging Trends in Science, Springer India,33-45 2012 [7] Raj M. Manglik Arthur E. Bergles Characterization of Twisted Tape-Induced Helical Swirl Flows for Enhancement of Forced Convective Heat Transfer in Single-Phase and Two-Phase Flows ASME J. Thermal Sci. Eng. Appl. 2013; 5(2): [8] B. V. N. Ramakumar, J. D. Arsha, Praveen Tayal Tapered Twisted Tape Inserts for Enhanced Heat Transfer ASME J. Heat Transfer. 2015; 138(1). [9] S.N. Sarada, A.V.S.R. Raju and K.K. Radha Experimental and Numerical Analysis of Turbulent Flow Heat Transfer Enhancement in a Horizontal Circular Tube Using Mesh Inserts Journal of Energy and Power Engineering, ISSN 1934-8975, USA July 2010, Volume 4, No.7 (Serial No.32) David Publishing. [10] P.Murugesan, K.Mayilsamy, S.Suresh Turbulent Heat Transfer and Pressure Drop in Tube Fitted with Square-cut Twisted Tape Chinese Journal of Chemical Engineering 18(4):609-617 August 2010. [11] S. Eiamsa-ard, C. Thianpong, P. Eiamsa-ard Turbulent heat transfer enhancement by counter/co-swirling flow in a tube fitted with twin twisted tape Experimental Thermal and Fluid Science Volume 34, Issue 1, January 2010, Pages 53 62 [12] S. V. Patil & P. V. Vijay Babu Laminar Heat Transfer Augmentation through A Square Duct and Circular Tube Fitted with Twisted Tape Experimental Heat Transfer: A Journal of Thermal Energy Generation, Transport, Storage, and Conversion Volume 27, Issue 2, 2014 [13] Sami D. Salman, Abdul Amir H. Kadhum, Mohd S. Takriff, Abu Bakar Mohamad CFD Simulation of Heat Transfer Augmentation in a Circular Tube Fitted with Alternative Axis Twisted Tape in Laminar Flow under a Constant Heat Flux WILEY Heat Transfer Asian Research Volume 43, Issue 4, pages 384 396, June 2014 [14] C.P. Kothandaraman, S. Subramanyan, Heat and Mass Transfer Data Book, Sixth Edition, New Age International Publishers, New Delhi, 2007 [15] Yunus.A.Cengel, Afshin.J.Ghajar, Heat and Mass Transfer, 4th edition, 2011,The McGraw-Hill Company. [16] R. M. Manglik and A. E. Bergles Heat Transfer and Pressure Drop Correlations for Twisted-Tape Inserts in Isothermal Tubes: Part II Transition and Turbulent Flows ASME J. Heat Transfer 1993; 115(4), 890-896. A Area of heat transfer m 2 d 0 D o H/D insert{ H/d i} Outer Diameter of Inner Pipe, m Outside diameter of annulus pipe, m Twist ratio = Pitch of insert/width of d i Inner Diameter of Inner Pipe, m D i Inside diameter of annulus pipe, m B Equivalent Diameter {(D 2 i -d 2 o )/ d 0 }, L t ΔP m c Side, LPM m h Sides, LPM Q C p T ih T oh ΔT h T avgh T ic T oc ΔT c Length of tube Thickness of Insert Pressure drop, mm of Hg Mass flow rate on Cold Water in Inner Pipe Mass flow rate on Hot Water in Annulus Rate of heat transfer, W Specific heat of fluid, kj/kg-k Inlet temperature of hot water, o C Outlet temperature of hot water, o C Temperature Difference of Hot Water, o C Average Temperature of Hot Water, o C Inlet temperature of cold water, o C Outlet temperature of cold water, o C Temperature Difference of Cold Water, o C NOMENCLATURE h inner pipe W/m 2 -K Heat transfer coefficient on Cold Inner pipe, Copyright to IJIRSET DOI:10.15680/IJIRSET.2015.0502001 1343 ΔP Side, Pa v LMTD Re Pr Nu K f Greek Symbols Subscripts Pressure Drop across Cold Water Inner Pipe Velocity of water on Cold Water Side, m/s Log Mean Temperature Difference Reynolds Number Prandt Number Nusselt Number Thermal conductivity of fluid, W/m-K Friction factor U Overall heat transfer coefficient, W/m 2 -K α Thermal diffusivity, m 2 /s μ Dynamic viscosity of fluid, Pa-s ρ Density, kg/m 3 ⱴ Kinematic viscosity of fluid, m 2 /s π Equivalent to (22/7) h c i o Hot water Cold water Inlet Outlet

ISSN(Online): 2319-8753 T avgc h annulus W/m 2 -K Average Temperature of Cold Water, o C Heat transfer coefficient on hot annulus side, Copyright to IJIRSET DOI:10.15680/IJIRSET.2015.0502001 1344