Case study: The Lead Tungstate Calorimeter for CMS

Similar documents
Calibration of the CMS Electromagnetic Calorimeter with first LHC data

Upgrade of the CMS Forward Calorimetry

CMS ECAL status and performance with the first LHC collisions

Calorimetry I Electromagnetic Calorimeters

THE main physics motivation for building the Compact

Highlights from the 9 th Pisa Meeting on Advanced Detectors Calorimetry Session

Introduction. Tau leptons. SLHC. Summary. Muons. Scott S. Snyder Brookhaven National Laboratory ILC Physics and Detector workshop Snowmass, Aug 2005

CMS: Tracking in a State of Art Experiment

M. Diemoz INFN Sezione di Roma, P.le A. Moro 2, Roma, Italy

READINESS OF THE CMS DETECTOR FOR FIRST DATA

Digital Calorimetry for Future Linear Colliders. Tony Price University of Birmingham University of Birmingham PPE Seminar 13 th November 2013

ATLAS Hadronic Calorimeters 101

Future prospects for the measurement of direct photons at the LHC

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Electron reconstruction and identification in CMS at LHC

LHCb Calorimetry Impact

Validation of Geant4 Physics Models Using Collision Data from the LHC

Performance of the CMS electromagnetic calorimeter during the LHC Run II

Il Calorimetro Elettromagnetico di CMS

Calibration and Monitoring for Crystal Calorimetry

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland. Commissioning of the CMS Detector

REVIEW OF CRYSTAL CALORIMETERS

Precision CMS PWO Crystal ECAL

The CMS Electromagnetic Calorimeter: overview, lessons learned during Run 1 and future projections

Studies on the e + e - spectrum with the first data of the CMS experiment at the Large Hadron Collider

The LHC Experiments. TASI Lecture 2 John Conway

Experimental Particle Physics

Tracker material study with the energy flow through the CMS electromagnetic calorimeter. Riccardo Paramatti, Ambra Provenza

Commissioning of the CMS Detector

Dual readout with tiles for calorimetry.

Status of the LHCb Experiment. Ueli Strauman, University of Zurich, Switzerland. Sept. 13, 2001

Search for high mass resonances in the diphoton and Zγ channels at LHC

Calorimetry in particle physics experiments

Adam Para, Fermilab CALOR2010, IHEP, Beijing May 14, 2010 TOTAL ABSORPTION HOMOGENEOUS CALORIMETER WITH DUAL READOUT

Commissioning and Calibration of the Zero Degree Calorimeters for the ALICE experiment

4. LHC experiments Marcello Barisonzi LHC experiments August

Interaction of particles in matter

Overview of validations at LHC

Analyses with photons or electrons with early LHC data at the CMS experiment

Lepton and Photon reconstruction and identification performance in CMS and ATLAS

The ATLAS Liquid Argon Calorimeter: Construction, Integration, Commissioning Ph. Schwemling on behalf of the ATLAS LAr Group

Commissioning of the ATLAS LAr Calorimeter

Experimental Particle Physics

PoS(EPS-HEP 2013)508. CMS Detector: Performance Results. Speaker. I. Redondo * CIEMAT

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Compact Muon Solenoid

pp physics, RWTH, WS 2003/04, T.Hebbeker

The BaBar CsI(Tl) Electromagnetic Calorimeter

LHC (ATLAS & CMS)

Muon commissioning and Exclusive B production at CMS with the first LHC data

Chapter 2 The CMS Experiment at the LHC

Experimental Particle Physics

Hadronic energy reconstruction in the combined electromagnetic and hadronic calorimeter system of the CALICE Collaboration

Reconstruction in Collider Experiments (Part IX)

Collider Physics Analysis Procedures

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

Identifying Particle Trajectories in CMS using the Long Barrel Geometry

Development of a Radiation Hard CMOS Monolithic Pixel Sensor

A RICH Photon Detector Module with G-APDs

Search for Displaced Supersymmetry using the Compact Muon Solenoid Detector

New Results from the DREAM project

Calorimetry From basic principles to particle flow an overview. Burkhard Schmidt, CERN PH-DT

Last Lecture 1) Silicon tracking detectors 2) Reconstructing track momenta

Performance of muon and tau identification at ATLAS

The reaction p(e,e'p)π 0 to calibrate the Forward and the Large Angle Electromagnetic Shower Calorimeters

The ATLAS Silicon Microstrip Tracker

Lecture 2 & 3. Particles going through matter. Collider Detectors. PDG chapter 27 Kleinknecht chapters: PDG chapter 28 Kleinknecht chapters:

Neutron Induced Nuclear Counter Effect in Hamamatsu Silicon APDs and PIN Diodes

Transverse momentum and pseudorapidity distributions with minimum bias events in CMS at the LHC

LSO/LYSO Crystal Development Ren-yuan Zhu

Compact Muon Solenoid Surapat Ek-In École Polytechnique Fédérale de Lausanne

A gas-filled calorimeter for high intensity beam environments

A NEW TECHNIQUE FOR DETERMINING CHARGE AND MOMENTUM OF ELECTRONS AND POSITRONS USING CALORIMETRY AND SILICON TRACKING. Qun Fan & Arie Bodek

AIM AIM. Study of Rare Interactions. Discovery of New High Mass Particles. Energy 500GeV High precision Lots of events (high luminosity) Requirements

INORGANIC crystal scintillators are widely used in high

CALICE scintillator HCAL

The CMS ECAL Laser Monitoring System

What detectors measure

Calorimetry in. in Nuclear and Particle Physics Experiments

Prospective of gamma hadron correlation. study in CMS experiment

Photons: Interactions

Non-collision Background Monitoring Using the Semi-Conductor Tracker of ATLAS at LHC

Calorimetry at LHC Davide Pinci INFN Sezione di Roma. Calorimetry at LHC 4th Summer School on THE PHYSICS OF LHC

HEAVY ION PHYSICS WITH CMS

arxiv: v1 [physics.ins-det] 10 Apr 2013

Particle Detectors A brief introduction with emphasis on high energy physics applications

Module of Silicon Photomultipliers as a single photon detector of Cherenkov photons

PHY492: Nuclear & Particle Physics. Lecture 25. Particle Detectors

Test setup, APDs,, preamps Calibration procedure Gain monitoring with LED Beam test results Future R&D options

Diameter 8.5 km Beam energy: 7 TeV Luminosity: Protons/bunch: 1.15x10 11 Bunches: 2808 Bunch spacing: 25 ns

Calorimeter test-beam results with APDs

Detectors in Nuclear and High Energy Physics. RHIG summer student meeting June 2014

Particle Flow Algorithms

Calorimeter for detection of the high-energy photons

Precision Crystal Calorimeters in High Energy Physics: Past, Present and Future

Hadronic Calorimetry

Measurement of the associated production of direct photons and jets with the Atlas experiment at LHC. Michele Cascella

Introduction of CMS Detector. Ijaz Ahmed National Centre for Physics, Islamabad

Jet quenching in PbPb collisions in CMS

A Search for Doubly Charged Higgs Production at 8 TeV Using the CMS Detector at the LHC

Transcription:

Case study: The Lead Tungstate Calorimeter for CMS (With acknowledgements to CMS colleagues, particularly R M Brown at RAL but all errors and omissions are the responsibility of Peter Hobson at Brunel!) Prof Peter R Hobson C.Phys M.Inst.P. Brunel University London, Uxbridge Peter.Hobson@brunel.ac.uk 1

The Compact Muon Solenoid Detector for LHC Physics goals: SUSY, Higgs, Heavy flavours, heavy ions ECAL Total mass : 13,500t Overall Diameter: 15.0m Overall Length: 21.6m Magnetic field: 4T 2

ECAL design objectives High resolution electromagnetic calorimetry is a basic design objective of CMS Benchmark physics process: Sensitivity to a low mass Higgs via H m /m = 0.5[ E1 /E 1 E2 /E 2 / tan( /2)] L = 10 34 cm 2 s -1 Vertex by track finding m H = 100 GeV Where E /E = a/ E b c/e Aim: Barrel End cap Stochastic term: a = 2.7% 5.7% (photoelectron statistics/shower fluctuations) Constant term: b = 0.55% 0.55% (non-uniformities, shower leakage) Noise term: Low L c= 155MeV 205MeV High L 210 MeV 245 MeV (Angular resolution limited by uncertainty in position of interaction vertex) 3

ECAL design choices ECAL (and HCAL) within magnetic vol Homogenous active medium (PbWO 4 ) Magnetic field-tolerant photodetectors with gain: - Avalanche photodiode (APD) for barrel - Vacuum phototriode (VPT) for end caps Pb/Si Preshower detector in end caps Properties of dense inorganic scintillators Property BGO BaF 2 CeF 3 PbWO 4 Density [g/cm 3 ] 7.13 4.88 6.16 8.28 Rad length [cm] 1.12 2.06 1.68 0.89 Int length [cm] 21.8 29.9 26.2 22.4 Molière rad [cm] 2.33 3.39 2.63 2.19 Decay time [ns] 60 300 0.9 630 8 25 5(39%) 15(60%) 100(1%) Refractive index 2.15 1.49 1.62 2.30 Max emiss [nm] 480 210 310 300 340 420 Temp coef [%/ºC] -1.6 0-2 0.14-2 Rel light yield 18 4 20 8 1.3 4

ECAL Parameters Parameter Barrel End caps Coverage η <1.48 1.48 < η < 3.0 Δφ x Δη Xtal size (mm 3 ) Depth in X 0 # of crystals Volume (m 3 ) Xtal mass (t) 0.0175 0.0175 21.8 21.8 230 25.8 61200 8.14 67.4 0.0175 0.0175 to 0.05 0.05 30.0 30.0 220 24.7 14648 2.7 22.0 3 off-pointing pseudoprojective geometry 5

Radiationlevels in ECAL cm 225 HB EB EE HE Absorbed dose after 10 years Relative light yield vs dose 0 0 400 cm 1.4x10 6 10 5 10 4 10 3 10 2 10 1 Gy 6 Neutron fluence (10 13 cm -2 ) = 1.48 Dose and neutron fluence Dose (kgy) Effect of radiation on PbWO 4 (after intense R&D) No change in scintillation properties Small loss in transmission through formation of colour centres Damage saturates Slow self-annealing occurs Loss in light yield of a few percent corrected with monitoring system No damage observed with neutrons BUT see later slides!

Photodetectors solid state Silicon is the primary material since in general we are detecting fast scintillation or Cherenkov light (near UV to visible) Silicon diode technology is well advanced and the quantum efficiency (QE) is high (around 80% peak) Silicon devices are tolerant to quite high radiation levels, although there are problems with hadrons. Silicon photodiodes are linear over many orders of magnitude The Avalance Photodiode has internal gain of about 30 (optimum value). See http://www.hamamatsu.com/jp/en/product/category/3100/4003/index.html 7

Photodetectors: barrel Avalanche photodiodes (APD) Operated at a gain of 50 Active area of 2 x 25mm 2 /crystal Q.E. 80% for PbWO 4 emission Excess noise factor is F = 2.2 Insensitive to shower leakage particles (d eff 6 m) Irradiation causes bulk leakage current to increase electronic noise doubles after 10 yrs - acceptable 8

Hamamatsu APD Hamamatsu type S8148 QE, Gain vs applied bias voltage, Excess Noise Factor See D. Renker, NIM A 486 (2002) 164 9

Photodetectors solid state Silicon is not cheaper per unit area than vacuum photodetectors (for areas greater than a few mm 2) Really large devices cannot be made (200 mm 2 is the upper limit) Problem of damage from high neutron flux in hadron collider experiments such as those at the LHC. Need low noise (= expensive) pre-amplifiers Hard to do photon counting. 10

Photodetectors: end caps Endcaps: Vacuum phototriodes(vpt) 12 10 8 Produced by RIE, St Petersburg, Russia More radiation resistant than Si diodes (with UV glass window) - Active area ~ 280 mm 2 - Gain ~10 (B=4T) Q.E.~ 20% (420 nm) - Fast devices (simple planar structure) = 26.5 mm MESH ANODE Gain 6 4 2 0 0 200 400 600 800 1000 11 V(A)=1000V V(A)=800V Dynode Voltage

VPT Characteristics 1.2 1.0 Rel. Anode Response 0.8 0.6 0.4 0.2 Response vs. Angle Induced absorbance 0.0 0.1 0.08 0.06 0.04 0.02 0-90 -60-30 0 30 60 90 VPT angle (deg.) 12 YT-49 Batch 30797a Only 19.38% kgy dose loss of transparency after 20 kgy (10 years) 300 400 500 600 700 800-0.02 Wavelength (nm) Critical magnetic field and radiation tolerance tests are done in the UK

Construction: barrel Submodule: 2x5 Xtals with APD and FE electronics in 200 m glass fibre alveola Module: 10x4 or 10x5 submodules mounted on a Grid, inside a basket Supermodule: 4 Modules (1700 Xtals) Barrel = 36 Supermodules Assembled Submodules 13

Construction: end caps The endcap is mechanically complex Tight tolerance on dimensions, deflections and thermal management. 14

Construction: end caps Supercrystal : carbon-fibre alveola containing 5x5 tapered crystals + VPTs + HV filter 156 Supercrystals per Dee All crystals have identical dimensions All Supercrystals are identical (apart from inner and outer circumference) 15

Evaluation of endcap crystals Crystal lab at ICSTM has studied in detail the formation and annealing of colour centres Ongoing developments have progressively increased the boule diameter: Two barrel crystals are now cut from a single boule in current production Even larger boules have been grown which could provide four crystals per boule 16 Transmission loss due to irradiation at 15 Gy/h for 24 hours. Induced absorption fitted with Gaussians at 2.3 ev (540nm) and 3.1 ev (400nm).

Preshower detector Rapidity coverage: 1.65 < < 2.6 (End caps) Motivation: Improved 0 / discrimination 2 orthogonal planes of Si strip detectors behind 2 X 0 and 1 X 0 Pb respectively Strip pitch: 1.9 mm (60 mm long) Area: 16.5 m 2 (4300 detectors, 1.4 x10 5 channels) High radiation levels - Dose after 10 years: ~ 2 x10 14 n/cm 2 ~60kGy Operate at -10 o C Incident Direction 17

0 / Discrimination ( -jet) is potentially the most serious background to H Track isolation cut reduces ( -jet) to 50% of the intrinsic ( - ) background (p T cut = 2GeV/c) Use 0 / discrimination in the ECAL to gain an extra margin of safety Barrel: Lateral shower shape in crystals (limited by crystal size at high E 0) End cap: Cluster separation in preshower (limited by shower fluctuations at 3X 0 ) 18

Test beam:energy Resolution No preshower detector 19

Energy resolution with preshower Energy resolution degraded by Pb absorber - partially restored using Si p.h. information 20 Excellent agreement between MC and data TDR performance achieved for E > 80 GeV ( E T >30 GeV - OK for H ) (even though Pb 10% too thick in this test!)

Laser Monitoring System DATA LINK DATA LINK ADC & OPTO CTRL OPTO ~1.3 TeV PREAMP APD CRYSTAL (1700/SM) PN FE SERIALISER ADC (x12) MEM CMS-ECAL MONITORING SYTEM 440 nm/500 nm 1 mj (2x10 15 ) 21 (200 Channels) LEVEL-1 LEVEL-2 SWITCH LASER FANOUT FANOUT (select SM/2)

Laser Correction for Effect of Radiation Damage 1.02 Laser Resp 1.0 Laser-Beam Correlation 1.02 Rel. Resp 1.0 Relative Response vs Time 0.98 0.98 0.96 0.94 0.96 Laser Electrons (laser corrected) Electrons (laser and temp corrected) 0.92 0.92 0.94 0.96 0.98 1.0 1.02 Beam Response 0.94 0 20 40 60 80 100 Time (Hours) 22

Trigger Readout architecture Upper-level VME readout (in Counting Room) PbWO 4 APD Preamp Gain ADC Serialiser Optical Crystal VPT select + VCSEL link On-detector light-to-light readout Pipeline control Interface DAQ Interface Trigger 40 MHz Clock 12 bit precision 4 different gains >17 bit dynamic range 23

Cosmic ray data CRAFT: Cosmic Run At Four Tesla continuous running for several weeks to gain operational experience > 300 M cosmic events collected magnetic field operated at 3.8T most CMS subsystems participating From Biino at ICATPP11 2009 24 Minimum ionizing particles deposit 250 MeV in ECAL. Increase efficiency: signal/noise enhanced (x4) in EB to the value of 20, by increasing the gain of the APD.

PbWO 4 Stopping Power Validate ECAL calibration with muons: measure energy deposition vs muon momentum momentum p measured in the CMS silicon tracker de: energy from ECAL cluster dx: length traversed in ECAL crystals de/ρdx energy deposit matched to the track corrected for muon path length 25 Tracker momentum matches well with ECAL energy loss, energy scale is correct From Biino at ICATPP11 2009

LHC data Data-taking with LHC beam. Wed, 10 Sept. 2008 26 Splash events observed when beam (450 GeV, 4.10 9 p) struck closed collimators 150m upstream of CMS Halo muons observed once beam (uncaptured and captured) started passing through CMS High energy deposit in the calorimeters, particles travelling horizontally Splash Event useful to commission forward detectors From Biino at ICATPP11 2009

27 Rapidity and Phi

28 Neutral pions

Intercalibration The precision of channel inter-calibration, using energy deposits, as a function of pseudo-rapidity in the ECAL barrel and endcap detectors 29

LHC radiation damage 30 Relative response to laser light (440 nm) measured by the ECAL laser monitoring system, averaged over all crystals in bins of pseudorapidity, for the 2011 and 2012 data taking periods

LHC radiation damage 31 Correcting for the effects of radiation damage using the laser monitoring system. Barrel calorimeter shown here.

The corrections work Instrumental resolution in barrel is 1 GeV at the Z peak The plot shows the improvements in Z->ee energy scale and resolution that are obtained from applying energy scale corrections to account for the intrinsic spread in crystal and photo-detector response, and timedependent corrections to compensate for crystal transparency loss 32

What about 13 TeV? Non-optimised data (shown at EPS conference) from early Run 2 data in 2015. MC number is normalised to data and calibration is based on an extrapolation from Run 1 constants. 33