Surface-mounting thermostats Series ATH

Similar documents
Surface-mounting Thermostats ATH Type Series

KM-70 Panel-mounting Thermostat

Surface-mounting double thermostat

EX-EMERGENCY LIGHT FITTINGS

ED 701 General Industry Pressure Transmitter

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

I nllk 08018/18 I nllk I nllk 08036/36 I nllk I I nllk 08058/58 I

Mineral-insulated thermocouples to DIN and EN

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

VK2 volume flow controller Overview

Operating Instructions for Digital Manometer. Model: MAN-SD

Capacitance Level Measurement Electronic Inserts EC 37 Z, EC 47 Z

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

ATEX/IECEx RTD temperature probe

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Cooling Water Flow Regulator

Air distribution systems. Radial outlet RA-N2...

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

DMP 331Pi. Precision Pressure Transmitter. pressure ports and process connections with flush welded stainless steel diaphragm

VD1 CLC. Small Valves DIN-range with a higher k v -value

Pressure Transmitter ED 701

Installation guide 862 MIT / MIR

Field IT 50T Series Transmitters

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

E X - C O N T R O L U N I T S A N D C O N T R O L S T A T I O N S

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Ex floating switches and Ex immersion probes

Lever-type Dial Test Indicators

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

Lever-type Dial Test Indicators

MINIATURE MICROSWITCHES - PREMIUM

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

Air distribution systems. Adjustable induction outlet IN-V...

PHOENIX CONTACT - 04/2016. Features

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

Pressure Measurement Single-range transmitters for general applications

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

microswitches Low force

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

Temperature Measurement

Switches in conformity with ATEX directive

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems

TF 212 / TF 212-Ex. Field mounted temperature transmitters, PROFIBUS PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels 10/11-8.

Fitting PS P - B - R2

Direct-operated 2/2-way solenoid valves Type EV210B

HYGRASGARD KFF KFTF HYGRASGARD AFF AFTF HYGRASGARD AFF - LC AFTF - LC

K Series SIGHT GLASS FOR CONVENIENT OBSERVATION OF LIQUID FLOW GENERAL

Pressure. 1 Fitting PA R - N R2

Z7A. Load cells. Special features. Data sheet. Wiring code

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

4.13. Ex-Floodlights of the series FMV LED / NSSFMV. (Zone 2, 22) service life and a high level of efficiency. NFMV floodlights for highpressure

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

Non-Contact Safety Systems CMS

AC axial compact fan

Full Metal Variable Area Flow Meter and Counter

Solenoid valves Type EVR 2 g 40 NC/ NO New EVR 6 with Steel cover design

SUBMINIATURE MICROSWITCHES - PREMIUM

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

Single Phase Motors Technical Datasheets

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

ct m ive p 5/EC Thermal cut-outs

MINIATURE MICROSWITCHES - PREMIUM

E8EB-N0C2B E8EB-N0B2B

Air distribution systems. Adjustable radial outlet RA-V...

AC axial compact fan

40 CD RANGE FLUSH-MOUNTING DISTRIBUTION BOARDS AND ENCLOSURES

Ex-Floodlights of the series FMV LED / NFMV / NSSFMV. Stainless steel NSSFMV floodlights for particularly. in harsh environments

Conductivity sensor for hygienic applications

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

Level Sensor PanCake PR 6251 and Mounting Kit PR 6051

DS 200 DS 200 DRUCK & TEMPERATUR LEITENBERGER GMBH. Electronic Pressure Switch. Stainless Steel Sensor. Electronic Pressure Switch

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

Explosion-protected recessed ceiling LED-light and fluorescent light fittings

Thermometers. Applications

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

VOLUMEC. Valve Position Indicator 5

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

Construction and application of resistance thermometers

FLOW SENSOR FOR LIQUID MEDIA Serie 210

Industrial Pressure Transmitter

Pushbutton Units and Indicator Lights

Hilti North America Installation Technical Manual Technical Data MI System Version

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Industrial Pressure Transmitter

Pressure transmitters for industrial applications MBS 32 and MBS 33

SUBMINIATURE MICROSWITCHES - STANDARD

Online data sheet WL280-S230 W280 COMPACT PHOTOELECTRIC SENSORS

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

S95.3U01 / S95.3U11. Head mounted temperature transmitters, programmable, Pt 100 (RTD), thermocouples, electrical isolation

AC axial compact fan

Transcription:

JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 20 2TT, UK Phone: +44 1279 635533 Fax: +44 1279 635262 E-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO PROCESS CONTROL INC. 885 Fox Chase, Suite 103 Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-mail: info@jumousa.com Internet: www.jumousa.com Data Sheet 60.3021 Page 1/10 Surface-mounting thermostats Series ATH Series IP54 Brief description Thermostats control and monitor thermal processes. Thermostats in the ATH series can be supplied as temperature controllers TR, temperature monitors TW, temperature limiters TB, safety temperature monitors STW (STB) and safety temperature limiters STB. In fault condition, the STB sets the system being monitored to a safe operational state. Surface-mounting thermostats operate on the principle of liquid expansion, with a microswitch serving as the electrical switching device. Switching function Temperature controller TR and temperature monitor TW When the temperature at the probe exceeds the set limit, the microswitch is operated through the mechanism and the circuit is opened or closed. When the temperature has fallen below the set limit (by the switching differential), the microswitch returns to its initial position. Lock-out facility on the temperature limiter TB and safety temperature limiter STB When the temperature at the probe exceeds the set limit, the circuit is opened and the microswitch is locked out mechanically. After the temperature has dropped below the safe temperature limit by about 10 % of span (about 15% for limit setting > +350), the microswitch can be reset manually. Use of the safety temperature monitor STW as safety temperature limiter STB In this case, the circuit connected to the thermostat must comply with DIN 3440 and with Section 8.7 of DIN/VDE 0116. Self-monitoring on the safety temperature limiter STB and safety temperature monitor STW (STB) In the case of the STB and STW (STB), failure of the measuring system, i.e. a leakage of the expansion fluid, will cause the pressure under the diaphragm to drop, thus permanently opening the circuit. A reset is now impossible. If the temperature at the probe cools down to below -20, the circuit will also be opened. As the temperature rises to above -20, the STB has to be reset manually, by pressing the reset button. On the STW (STB), the reset is performed automatically. ATHs-1 ATHf-/g s and approvals s Switching function DIN Reg. No. Tests You will find the with rigid stem with capillary ATHs-10 ATHf-10 TR TR 89 101 ATHs-20 ATHf-20 TW TW 89 201 ATHs- ATHf- TB TB 89 301 ATHs-20 ATHf-20 STW (STB) STW (STB) 89 401 S ATHs- ATHf- STB STB 89 501 - DIN 3440 - Pressure Equipment Directive 97/23/EC (ATH.-20 and ATH.- only) Declarations of Conformity on the Internet at: www.jumo.net Products Thermostats Data Sheet 60.3021 or they can be sent to you on request.

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.3021 Page 2/10 Technical data Control ranges and temperature probes Control / limit ranges in ATH.-1 ATH.-2 ATH.-7 ATH.-20 ATH.- ATH.-1 ATH.-2 ATH.-7 ATH.-20 ATH.- -50 to +030-20 to +050-10 to +040 +00 to+050 +00 to+0 +00 to+100 +20 to +090 +30 to +110 +20 to +120 +60 to +130 +20 to +150 +50 to +200 +50 to +250 +50 to +300 +50 to +350 +30 to +110 +60 to +130 +20 to +150 +50 to +250 +50 to +300 +20 to +400 +20 to +500 +20 to +500 +20 to +400 +20 to +500 +20 to +500 Max. permissible probe temperature in 050 060 050 060 080 125 115 135 140 150 175 230 290 345 405 135 150 175 290 345 460 550 550 460 550 550 liquid-filled gas-filled Maximum capillary length in 5000 5000 1000 2000 4000 1000 2000 4000 Probe length L in probe dia. d in, dia. 6 is standard 6 8 128 141 185 185 138 107 138 125 106 135 088 101 073 063 053 108 116 077 064 055 278 148 202 176 127 202 085 092 115 115 091 075 091 084 075 090 065 072 054 049 - - - 075 079 060 049 - - - 158 092 119 106 081 119 Capillaries and temperature probes End of scale Capillary Temperature probe Note ATH.-.. up to 200 copper (Cu) 1.5 dia. Mat. Ref. 2.0090 up to 350 copper (Cu) 1.5 dia. Mat. Ref. 2.0090 up to 500 stainless steel (CrNi) 1.5 dia. Mat. Ref. 1.4571 up to 350 stainless steel (CrNi) 1.5 Mat. Ref. 1.4571 Capillary length Min. bending radius of capillary copper (Cu) Mat. Ref. 2.0090 brazed stainless steel (CrNi) Mat. Ref. 1.4571 brazed stainless steel (CrNi) Mat. Ref. 1.4571 welded stainless steel (CrNi) Mat. Ref. 1.4571 welded standard is: 1000, max. 5000 5 at extra charge

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.3021 Page 3/10 Electrical data Switching device ATH.-1 ATH.-2 ATH.-20 microswitch with changeover contact ATH.-7 ATH.- microswitch with break contact and lock-out ATH.-7/U ATH.-/U microswitch with break contact, lock-out and additional signal contact Max. rating 10 (2) A, 230 V AC +10%, p.f. = 1 (0.6) 0.25A, 230 V DC +10% with differential 1.5% und 2% 6 (1.2) A, 230 V AC +10%, p.f. = 1 (0.6) microswitch gold-plated, code /au 0.1 A, 24 V AC / DC +10%, contact resistance 2.5 10 mω Operating data Switching differential in % of control / limit range Switching point accuracy in % of control / limit range Ambient temperature error referred to control / limit range Permissible storage temperature Permissible ambient temperature in operation Nominal position (NL) Switching function liquid-filled measuring system Nominal value Possible actual value TR, TW 3 3 max. 4 standard 6 6 max. 8 on request 1.5 1 max. 2 at extra charge gas-filled measuring system 5 4 max. 8 standard 9 8 max. 12 on request 2 1.5 max. 2.5 at extra charge liquid-filled measuring system STW (STB) 5 4 max. 6 standard 9 8 max. 11 on request 2 1 max. 3 at extra charge gas-filled measuring system 7 5 max. 12 standard 9 8 max. 16 on request 2 1.5 max. 3 at extra charge TR: in upper third of scale ± 1.5%, at start of scale ± 6% TW, TB, STB, STW (STB): in upper third of scale +0/-5%, at start of scale +0/-10% A deviation of the ambient temperature at the case from the 22 calibration ambient temperature produces a shift in the switching point: higher ambient temperature = lower switching point lower ambient temperature = higher switching point Surface-mounting thermostats with end-of-scale value < 200 200 350 > 350 500 TR / TW / TB STB/STW (STB) TR / TW / TB STB/STW (STB) TR / TW / TB STB/STW (STB) due to thermostat head 0.08%/ 0.17%/ 0.06%/ 0.13%/ 0.14%/ 0.12%/ due to capillary per meter length 0.047%/ 0.054%/ 0.09%/ 0.11%/ 0.04%/ 0.03%/ -50 to +50 +80 max. to DIN 16 257, NL 0 NL 90 (other NL on request)

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.3021 Page 4/10 Case Standard * cover: polycarbonate, impact-resistant base: die-cast aluminium, painted color: pebble gray RAL 32 color: anthracite gray RAL 15 Code a cover: die-cast aluminium, painted color: pebble gray RAL 32 Setpoint adjustment ATH-1: switching point adjustable from the outside by turning the knob ATH-2, ATH-20, ATH-7, ATH-: switching point adjustable by screwdriver after taking off case cover Protection EN 60 529-IP54 Cable entry as standard: clamping gland M20 x 1.5, for 8 10 cable diameter Weight approx. 0.5 kg Thermostat mounting, Series ATHf-.. with capillary Series ATHswith rigid stem Standard Code r b k thread M 18 x 1 with locknut on case spigot, capillary exit at spigot by 2 screws through base of case, capillary exit on side of case, cover and base in plastic mounting flange in steel, capillary exit at case spigot wall bracket End of scale up to 150 Pocket U screw-in pocket with screw-in spigot G 1/2 Form A to DIN 3852/2 *other process s and pockets, see Data Sheet 60.10. Note: Physical and toxicological properties of the expansion media which may escape in the event of a system fracture. 1) At present there is no restrictive statement from the health authorities concerning any danger to health over short periods and at low concentrations, for example after a fracture of the measuring system. End of scale above 150 Pocket UZ screw-in pocket with screw-in spigot G 1/2 Form A to DIN 3852/2 and extension, in order not to exceed the max. permissible ambient temperature +80 at the case Series plain cylindrical probe A (standard) ATHfwith capillary pocket U (on resquet) screw-in pocket with screw-in spigot G 1/2 Form A to DIN 3852/2 and clip with fixing screw for securing the probe Material Pocket U Pocket UZ up to +150 CuZn (brass) as standard above +150 St (steel) as standard (CrNi on request) above +150 St (steel) as standard (CrNi on request) Fitting length S standard lengths: 100, 120, 150, 200 or 300 other lengths on request Iersion tube dia. D = 8, D = 10 Control range with end of scale Dangerous reactions Fire/explosion hazard ignition temperature explosion limit % v/v Water contamination irritant < +200 no + 280 1.2 7.5 yes yes Toxicological data danger to health 1) 200 +350 no + 490 1 3.5 V yes yes 1) no > 350 +500 no no no no no no no Connection diagrams toxic no ATH.-1 ATH.-2 ATH.-20 ATH.-7 ATH.- ATH.-7/U ATH.-/U

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.3021 Page 5/10 Dimensions ATHs-1, with pocket U 23 66 hex SW M20x1.5 L1 33 G S D ATHs-2, ATHs-20 with pocket UZ M20x1,5 _85 66 27 SW27 a/f 14 33 G1/2 S D ATHf-7 ATHf-, with pocket U 38 18 SW24 M20x1.5 SW hex G 66 M18x1 D L1 S

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.3021 Page 6/10 ATHf-1/b, with pocket U M20x1.5 SW hex L1 G S 66 23 Ø 6.5 65 D ATHf-2/r, ATHf-20/r with plain cylindrical probe A, no pocket 72 Ø4.5 M20x1.5 45 drilling Bohrplan diagram L d ATHf-7/k ATHf-/k, with plain cylindrical probe A, no pocket Ø 7 50 9 d L66 M20x1.5 43

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.3021 Page 7/10 Stock items with rigid stem Temperature controller (TR) Iersion tube dia. x length 60/60001517 ATHs-1 10 to + 40 3-4 U G 1 / 2 8x200 60/60000139 ATHs-1 +20 to+ 50 1.5 U G 1 / 2 15x100 60/60000634 ATHs-1 +20 to+ 50 1.5 U G 1 / 2 15x100 CrNi 60/60000479 ATHs-1 +20 to+ 50 3-4 U G 1 / 2 8x200 60/600001* ATHs-1 +20 to+ 50 3-4 U G 1 / 2 8x300 60/60000141 ATHs-1 +20 to + 90 6-8 U G 1 / 2 15x100 60/60000171 ATHs-1 +20 to + 90 3-4 U G 1 / 2 8x150 60/60000172* ATHs-1 +20 to + 90 3-4 U G 1 / 2 8x300 60/60000173 ATHs-1 +20 to +100 1.5 U G 1 / 2 8x120 60/60000332 ATHs-1 +20 to +100 3-4 U G 1 / 2 8x120 60/60001548 ATHs-1 +20 to +100 3-4 U G 1 / 2 8x120 CrNi 60/60001125 ATHs-1 +20 to +100 3-4 U G 1 / 2 8x150 60/60000174 ATHs-1 +20 to +100 1.5 U G 1 / 2 8x200 60/60001126 ATHs-1 +20 to +100 3-4 U G 1 / 2 8x200 60/60000175 ATHs-1 +20 to +100 3-4 U G 1 / 2 8x300 60/60001034 ATHs-1 +20 to +120 3-4 U G 1 / 2 8x150 60/60000481 ATHs-1 +20 to +150 3-4 U G 1 / 2 8x100 60/60001547 ATHs-1 +20 to +150 3-4 U G 1 / 2 8x100 CrNi 60/60001035 ATHs-1 +20 to +150 3-4 U G 1 / 2 8x200 60/60001127 ATHs-1 +20 to +150 3-4 U G 1 / 2 8x300 60/60001037 ATHs-1 +50 to +200 3-4 UZ G 1 / 2 8x200 60/60001036 ATHs-1 +50 to +300 3-4 UZ G 1 / 2 8x150 60/60002123 ATHs-1 +20 to +500 5 UZ G 1 / 2 8x200 *model is being phased out Temperature monitor (TW) *model is being phased out Iersion tube dia. x length 60/60001135 ATHs-2 10 to + 40 3-4 U G 1 / 2 8x200 60/60000960 ATHs-2 +20 to + 50 1.5 U G 1 / 2 15x100 60/60001549 ATHs-2 +20 to + 50 1.5 U G 1 / 2 15x100 CrNi 60/60001128 ATHs-2 +20 to + 50 3-4 U G 1 / 2 8x200 60/60000176* ATHs-2 +20 to + 50 3-4 U G 1 / 2 8x300 60/60000177 ATHs-2 +20 to + 90 1.5 U G 1 / 2 15x100 60/60000959 ATHs-2 +20 to + 90 6-8 U G 1 / 2 15x100 60/60001129 ATHs-2 +20 to + 90 3-4 U G 1 / 2 8x150 60/60000178 ATHs-2 +20 to + 90 3-4 U G 1 / 2 8x200 60/60000331 ATHs-2 +20 to +100 3-4 U G 1 / 2 8x120 60/60001552 ATHs-2 +20 to +100 3-4 U G 1 / 2 8x120 CrNi 60/60000179 ATHs-2 +20 to +100 3-4 U G 1 / 2 8x150 60/60001039 ATHs-2 +20 to +100 3-4 U G 1 / 2 8x200 60/60001130 ATHs-2 +20 to +100 3-4 U G 1 / 2 8x300 60/60001124 ATHs-2 +20 to +150 1.5 U G 1 / 2 8x100 60/60000483 ATHs-2 +20 to +150 3-4 U G 1 / 2 8x100 60/60001551 ATHs-2 +20 to +150 3-4 U G 1 / 2 8x100 CrNi 60/60000485 ATHs-2 +20 to +150 3-4 U G 1 / 2 8x200 60/60001554 ATHs-2 +20 to +150 3-4 U G 1 / 2 8x200 CrNi 60/60000182 ATHs-2 +20 to +150 3-4 U G 1 / 2 8x300 60/60000186 ATHs-2 +50 to +200 3-4 UZ G 1 / 2 8x120 60/60001131 ATHs-2 +50 to +200 3-4 UZ G 1 / 2 8x200 60/60000185* ATHs-2 +50 to +200 3-4 UZ G 1 / 2 8x300 60/60001105 ATHs-2 +50 to +300 3-4 UZ G 1 / 2 8x150 60/60001556 ATHs-2 +50 to +300 3-4 UZ G 1 / 2 8x150 CrNi 60/60002124 ATHs-2 +20 to +500 5 UZ G 1 / 2 8x200

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.3021 Page 8/10 Stock items with rigid stem Safety temperature monitor STW (STB) Iersion tube dia. x length 60/60001478 ATHs-20 +20 to +150 4-6 U G 1 / 2 8x150 60/60000188 ATHs-20 +50 to +300 4-6 UZ G 1 / 2 8x200 60/60002217 ATHs-20 +50 to +350 4-6 EZS G 3 / 4 1 60/60000885 ATHs-20 +20 to +500 7 UZO G 1 / 2 200 Safety temperature limiter (STB) Iersion tube dia. x length 60/60000982 ATHs- + 30 to +110 U G 1 / 2 8x150 60/60001043 ATHs- + 30 to +110 U G 1 / 2 8x200 60/60000189 ATHs- + 30 to +110 U G 1 / 2 8x300 60/60001044 ATHs- + 60 to +130 U G 1 / 2 8x150 60/60000190 ATHs- + 60 to +130 U G 1 / 2 8x200 60/60001020 ATHs- + 20 to +150 U G 1 / 2 8x200 60/60000120 ATHs- +130 to +200 UZ G 1 / 2 8x150 60/60001042 ATHs- +130 to +200 UZ G 1 / 2 8x300 60/60001132 ATHs- + 50 to +300 UZ G 1 / 2 8x200 60/60001524 ATHs-/U + 30 to +110 U G 1 / 2 8x150 60/60001522 ATHs-/U + 20 to +150 U G 1 / 2 8x200 60/60001523 ATHs-/U + 50 to +300 UZ G 1 / 2 8x200 60/60002218 ATHs-/U + 50 to +350 EZS G 3 / 4 1 60/60000884 ATHs-/U + 20 to +500 UZO G 1 / 2 200 60/60002121 ATHs-/U + 20 to +500 UZ G 1 / 2 8x200 Stock items with capillary Temperature controller (TR) Capillary Probe dia. x length 60/60001134 ATHf-1 10 to +040 3-4 1000 A 6x185 60/60000477 ATHf-1 +20 to+050 3-4 1000 A 6x185 60/60001193 ATHf-1 +20 to +090 3-4 1000 A 6x138 60/60001004 ATHf-1 +20 to +100 3-4 1000 A 6x107 60/60000955 ATHf-1 +20 to +150 3-4 1000 A 6x 88 60/60001133 ATHf-1 +50 to +300 3-4 1000 A 6x 63 60/60002113 ATHf-1 +20 to +500 5 1000 A 6x148 Temperature monitor (TW) 60/60000482 ATHf-2 +00 to+050 3-4 1000 A 6x185 60/60001192 ATHf-2 +00 to+050 3-4 2000 A 6x185 60/60000965 ATHf-2 +20 to +090 3-4 1000 A 6x138 60/60001211* ATHf-2 +20 to +090 3-4 2000 A 6x138 60/60000962 ATHf-2 +00 to +100 3-4 1000 A 6x107 60/60001212 ATHf-2 +00 to +100 3-4 2000 A 6x107 60/60000963 ATHf-2 +20 to +150 3-4 1000 A 6x 88 60/60001210 ATHf-2 +20 to +150 3-4 2000 A 6x 88 60/60000187 ATHf-2 +50 to +200 3-4 1000 A 6x101 60/60001209 ATHf-2 +50 to +200 3-4 2000 A 6x101 60/60001038 ATHf-2 +50 to +300 3-4 1000 A 6x 63 60/60001208 ATHf-2 +50 to +300 3-4 2000 A 6x 63 60/60002122 ATHf-2 +20 to +500 5 1000 A 6x148 60/60002114 ATHf-2 +20 to +500 5 2000 A 6x148 *model is being phased out Capillary Probe dia. x length

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.3021 Page 9/10 Stock items with capillary Safety temperature limiter (STB) Capillary Probe dia. x length 60/60002261 ATHf-20/r + 20 to +500 7 4000 ES G 3 / 4 200 60/60001136 ATHf- + 30 to +110 1000 A 6x108 60/60001206 ATHf- + 30 to +110 2000 A 6x108 60/60001097 ATHf- + 60 to +130 1000 A 6x116 60/60001041 ATHf- + 20 to +150 1000 A 6x 77 60/60001205 ATHf- + 20 to +150 2000 A 6x 77 60/60001525 ATHf-/U + 20 to +150 1000 A 6x 77 60/60001204 ATHf- + 50 to +200 2000 A 6x 85 60/60001290 ATHf-/U + 50 to +200 1000 A 6x 85 60/60001002 ATHf- +130 to +200 1000 A 6x114 60/60001040 ATHf- + 50 to +300 1000 A 6x 55 60/60001191 ATHf- + 50 to +300 2000 A 6x 55 60/60001528 ATHf-/U + 50 to +300 1000 A 6x 55 60/60002086 ATHf- + 20 to +500 1000 A 6x127 60/60002088 ATHf-/U + 20 to +500 1000 A 6x127 60/60002099 ATHf-/U + 20 to +500 2000 A 6x127 60/60002262 ATHf-/U/r + 20 to +500 4000 ES G 3 / 4 200 Order details for items not available from stock Series ATH Order code (1) Basic type 603021-1-0001 ATHs-1 Temperature controller with rigid stem 603021-1-0002 ATHs-2 Temperature monitor with rigid stem 603021-1-0007 ATHs-7 Temperature limiter with rigid stem 603021-1-0020 ATHs-20 Safety temperature monitor with rigid stem 603021-1-00 ATHs- Safety temperature limiter with rigid stem 603021-2-0001 ATHf-1 Temperature controller with capillary 603021-2-0002 ATHf-2 Temperature monitor with capillary 603021-2-0007 ATHf-7 Temperature limiter with capillary 603021-2-0020 ATHf-20 Safety temperature monitor with capillary 603021-2-00 ATHf- Safety temperature limiter with capillary (2) Control / limit ranges 11-50 to +030 14-20 to +050 16-10 to +040 21 +00 to+050 22 +00 to+0 25 +00 to+100 41 +20 to +090 52 +30 to +110 42 +20 to +120 66 +60 to +130 43 +20 to +150 62 +50 to +200 63 +50 to +250 64 +50 to +300 45 +20 to +400 46 +20 to +500 (3) Switching differential 00 no differential (-7 TB / - STB) 15 1.5% of scale span (TR + TW only) 20 2% of scale span (STW (STB only)) 30 3% of scale span (TR + TW only) 50 5% of scale span (TR + TW + STW (STB) only) 60 6% of scale span (TR + TW only) 7% of scale span (STW (STB) only) 90 9% of scale span (STW (STB) only)

M. K. JUCHHEIM GmbH & Co 36035 Fulda, Germany Data Sheet 60.3021 Page 10/10 Series ATH (4) Capillary length 0000 ATHs- no capillary 1000 1000 2000 2000 3000 3000 4000 4000 5000 5000.... (special length, details in plain text) (5) Material of capillary 00 ATHs- no capillary 40 Cu (copper) 20 CrNi (stainless steel 1.4571) (6) (PA) * 10 A = plain cylindrical probe (ATHf only) 20 U = screw-in pocket 30 UZ = screw-in pocket with extension (7) Thread for process * 00 no thread (process A) 13 external thread G 1/2 (8) Material of process 00 only with process A 46 CuZn (brass) 01 St (steel) 20 CrNi (stainless steel 1.4571) (9) Fitting length S (iersion tube length) 000 ATHf- no pocket 100 100 120 120 150 150 200 200 300 300 400 400........ special length, details in plain text (10) Diameter D (iersion tube dia.) 00 ATHf- no pocket 08 08 10 10 (11) Diameter d (probe dia.) 6 6 8 8 (12) Extra codes 000 no extra code 574 U TB / STB with break contact, lock-out and additional signal contact (-7 TB / - STB) 2 au snap-action switch contacts gold-plated 1 a case cover die-cast aluminium (not with extra code r) 711 r thermostat head mounting by 2 screws through base of case, capillary exit on side of case, cover and base in plastic 764 b mounting flange in sheet steel, capillary exit at case spigot 248 k wall bracket * for other types and pockets, see Data Sheet 60.10. Order code (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (12) (12) /.. -.. -.... -.. -.. -.. -.. -... -.. -. /... /... /... Order example 603021-2-0002 / 43-30 - 4000-20 - 10-00 - 00-000 - 00-6 / 248 / 000 / 000