Noncontact Thermometer

Similar documents
Introduction Cautions

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

63/66/68. Infrared Thermometers. Users Manual

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

Model ST-616CT. Instruction Manual. Infrared Thermo-Hygrometer. reedinstruments. www. com

Gun-Type Professional Infrared Thermometer MODEL: ST 653. Instruction Manual

InfraRed Thermometer with Laser Pointer

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Infrared Thermometer Model: and

Instruction Manual SEFRAM Thermal Camera

IR-712 IR-712-EUR 12:1 Infrared Thermometer. IR-720 IR-720-EUR 20:1 Infrared Thermometer. IR-730 IR-730-EUR 30:1 Infrared Thermometer.

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Model DIT-516/517: OPERATING MANUAL

Hot solutions for temperature measurement. Contact and non-contact thermometers from Fluke

GS-IR 8816 Series Infrared Thermometer

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

The Fluke 66 and 68 Infrared Thermometers

566/568. Infrared Thermometers. Getting Started

INFRARED THERMOMETER Model : TM-959

INFRARED THERMOMETER TM0819

DHS1900 DHS3000 High Temperature Hand Held Infrareds User Manual

IR-712 IR-720 IR-730

INSTRUCTION MANUAL Fax: (503)

IR/Thermistor Pen. Instruction Manual

Infrared Thermometer Model CA879

Dual laser + type K thermometer INFRARED THERMOMETER

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

saxon Instruction Manual saxon Grandeur Brass Telescope High quality optics

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

User s Guide. Shown with Built-in Laser Sighting. OS531, OS532, OS533, OS534 OMEGASCOPE Handheld Infrared Thermometer

USER MANUAL REFLEX SIGHT. Ultra Shot Z Series. English / Francais / Español / Deutsch

Infrared Hand-Held Thermometers

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

6XMag-1 Magnifier User manual

INSTRUCTION MANUAL DTH Fax: (503)

ABB temperature measurement Radiation thermometry. Measurement made easy. Process temperature measurement practice--non-contacting

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Instruction Manual. HI Refractometer for Sucrose in Wine and Grape Products Measurements

OPERATING INSTRUCTIONS

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

INSTRUCTION MANUAL Milwaukee Refractometer MA872 Refractometer for Fructose Measurements

Wireless Weather Station Instruction Manual

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

DIGITAL THERMOMETER WITH TRICOLOR LCD INSTRUCTION MANUAL

Wireless Weather Station. Instruction Manual

Instruction Manual HI Refractometer for Invert Sugar Measurements

Red and Green Dot Sight FF26002 USER MANUAL

symphony Multisensor Probes

IR-750. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok. 50:1 IR Thermometer with memory

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

INTRODUCTION TO ENGINEERING SURVEYING (CE 1305)

Infrared Hand-Held Thermometers

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE

Non contact temperature measurement

Rapid RH Portable ph Meter. User's Manual

ULTRA SHOT PLUS - DARK EARTH REFLEX SIGHT SM26008DE

USER MANUAL REFLEX SIGHT. Ultra Shot Plus

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

Basic Operation Adjust the eyecup

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

INSTRUCTION MANUAL INF Fax: (503)

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

THERMOFOCUS, a technological innovation

Traceable Big-Digit Type-K Thermometer Big digits are readable from 15 feet away. For additional Type-K probes, see page 41.

Thermometer Line. today s laboratory and field

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

NcSTAR SHOOTER II SERIES SCOPE

What is the maximum distance I can have the remote sensors from the display?

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

Manual Dew point scanner PCE-DPT 1

IT Series Infrared thermometer Using manual

2-7x32. Instruction manual

LEAPERS, INC. RED/GREEN DOTS

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

Table of Contents. Specifications 1 Adjustments 2 Using the Reticle 8 Maintenance 16 Troubleshooting 18 SS Warranty 19

DIGITAL THERMOMETER OPERATOR S MANUAL

CONTENTS. La Crosse Technology, Ltd. Page 1

15 E OWNER S MANUAL PIRATE SPYGLASS BRING EM NEAR PIRATE SPYGLASS TELESCOPE 5 W 30 W 60 W 45 W

ED 701 General Industry Pressure Transmitter

Instruction Manual HI Refractometer for Sodium Chloride Measurements

1x COMBAT DOT SIGHT USER MANUAL

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

FIG. 1 FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6 FIG. 7

Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR

1551A Ex/1552A Ex Intrinsically Safe Stik Thermometer. The new gold standard of industrial temperature calibration

IR 80-H. Non-Contact Infrared Temperature Sensor/Transmitter. Temperature Range: 500~1700

WS-7213U Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS. Figure 2. Figure 1

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

WS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual

Full Color SMT Chip LED (3.5 x 3.0 x 1.4 mm)

One-Year Limited Warranty

Operator s Manual SpecterOS 4x by ELCAN

Transcription:

InfraPro 1 Standard Model 35629-00 InfraPro 2 Enhanced Model 35629-10 Noncontact Thermometer 57511-1 Rev. A 4/00

Specifications Temperature range 35629-00 -32 to 400 C (-25 to 750 F) 35629-10 -32 to 545 C (-25 to 950 F) D : S 12 : 1 (35629-10 has 90% encircled energy at the Display Resolution focal point) 0.2 C (0.5 F) Accuracy For targets: (assumes ambient Above 23 C (73 F): ±1% of reading or ±1 C (± 2 F), operating temperature whichever is greater of 23-25 C[73-77 F]) -18 to 23 C (0 to 73 F): ± 2 C (± 3 F) @ calibration geometry* -26 to -18 C (-15 to 0 F): ± 2.5 C (± 4 F) -32 to -26 C (-25 to -15 F): ± 3 C (± 5 F) Repeatability Response time ± 1 C (± 2 F), or ± 0.5% of reading, whichever is greater 500 msec Spectral response 8 14 µm Emissivity pre-set 0.95 Ambient operating range Laser Max Relative humidity Storage temperature Weight / Dimensions Power Typical Battery life (Alkaline) Tripod Mount 0 to 50 C (32 to 120 F) Laser turns off above 40 C (104 F) ambient temperature 10 95% RH noncondensing, at 30 to 50 C (86 to 122 F) -20 to 60 C (-13 to 158 F) without battery 320g (11oz); 200 x 160 x 55 mm (8 X 6 X 2 in) 9V Alkaline or NiCd battery 10 hours with laser and backlight on 40 hours with laser and backlight off 1/4 20 UNC threading *Unit calibrator is 279.4mm (11 in.) from the 140mm (5.5 in.) 0.95 emissivity backbody.

Display Anzeige Affichage Pantalla Display Laser Laser Laser Láser Laser C/ F Switch C/ F-Schalter Commutateur C/ F Interruptor de C/ F Chave C/ F Backlight On/Off Switch Schalter für Displaybeleuchtung Commutateur Rétro-éclairage Interruptor de Encendido de Luz de Fondo. Interruptor da Retroiluminação Trigger Meßtaste Gâchette Gatillo Gatilho Battery Compartment Batteriefach Logement des piles Compartimento de las pilas Compartimento de bateria Battery Cover Batterieabdeckung Couvercle du lcompartiment pile Tapa de las pilas Tampa da bateria

English Warning Do not point laser directly at eye or indirectly off reflective surfaces. Cautions All models should be protected from the following: EMF (electro-magnetic fields) from arc welders, induction heaters Static electricity Thermal shock (caused by large or abrupt ambient temperature changes allow 30 minutes for unit to stabilize before use) Do not leave the unit on or near objects of high temperature 4

English Features Your thermometer includes: Single-point laser sighting (Standard Model) Circular laser sighting (Enhanced Model) MAX temperature display Backlit graphic display Tripod mount Durable, ergonomic construction Options/Accessories Nylon Holster N.I.S.T./DKD Certification Display A) Low battery indicator (comes on when battery is low) B) C/ F symbol C) Maximum temperature value (continuously updated while the unit is on) D) Temperature display E) Scan/Hold indicator In the scan mode, the backlit LCD displays both the current temperature (D) and maximum temperature (C) in Celsius or Fahrenheit (B). The unit will hold the last reading for 7 seconds after the trigger is released; the word HOLD appears (E). The presence of the battery icon (A) indicates a low battery. E D A B C 5

English Introduction We are confident you will find many uses for your handheld noncontact thermometer. Compact, rugged, and easy to use just aim, pull the trigger, and read the temperature in less than a second. You can safely measure surface temperatures of hot, hazardous, or hard-to-reach objects without contact. How it Works Infrared thermometers measure the surface temperature of an object. The unit s optics sense emitted, reflected, and transmitted energy, which are collected and focused onto a detector. The unit s electronics translate the information into a temperature reading which is displayed on the unit. The laser is used for aiming purposes only. 6

How to Operate the Unit Measurement: Quick Start To measure a temperature, point the unit at an object, and pull the trigger. Be sure to consider distance-to-spot size ratio and field of view. When using the laser, use it only for aiming. For more detailed operating instructions, see How to Accurately Measure Temperatures. English Switching C and F; Changing the Battery; Laser and Backlight On/Off To open the unit s handle, push the button near the trigger on the underside of the unit, and pull the handle down and forward. To select C or F, slide the top switch (A) up for Celsius and down for Fahrenheit. To activate the laser and backlight, slide the lower switch (B) down. The laser and backlight will turn on when the trigger is pulled. The laser will turn off when the trigger is released. The backlight will remain on for 7 seconds after the trigger is released. To change the 9V battery, insert it with positive side toward the rear of the battery compartment. A B Button 7

English How to Accurately Measure Temperature Locating a Hot or Cold Spot To find a hot or cold spot, aim the thermometer outside the area of interest. Then scan across the area with an up and down motion until you locate the hot or cold spot. Yes No Field of View Make sure that the target is larger than the unit s spot size. The smaller the target, the closer you should be to it. When accuracy is critical, make sure the target is at least twice as large as the spot size. 8 Emissivity Emissivity is a term used to describe the energy-emitting characteristics of materials. Most organic materials and painted or oxidized surfaces have an emissivity of 0.95 (pre-set in the unit). Inaccurate readings can result from measuring shiny or polished metal surfaces. To compensate, cover the surface to be measured with masking tape or flat black paint. Allow time for the tape or paint to reach the same temperature as the the material underneath it. Measure the temperature of the tape or painted surface.

English Distance & Spot Size As the distance (D) from the object increases, the spot size (S) of the area measured by the unit becomes larger. The relationship between distance and spot size is 12:1 at the focus point (0.914 meter/36 inches). The spot sizes indicate 90% encircled energy. Circular Laser Sighting The circular laser is made up of eight laser spots that form a circle to show the approximate area being measured; a single laser spot shows the center of the measurement area. In low-light conditions, lighter spots surrounding the laser circle may appear. These spots are not used for aiming purposes. Use only the laser circle to aim the unit. Reminders Not recommended for use in measuring shiny or polished metal surfaces (stainless steel, aluminum, etc.). See Emissivity for measuring these surfaces. The unit cannot measure through transparent surfaces such as glass or plastic. It will measure the surface temperature of these materials instead. Steam, dust, smoke, or other particles can prevent accurate measurement by obstructing the unit s optics. 9

English Maintenance Lens Cleaning: Blow off loose particles using clean compressed air. Gently brush remaining debris away with a camel's hair brush. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water. NOTE: DO NOT use solvents to clean the plastic lens. Cleaning the housing: Use soap and water on a damp sponge or soft cloth. NOTE: DO NOT submerge the unit in water. Troubleshooting Code Problem Action (on display) Target temperature Select target within specifications is over or under range Battery icon Low battery Check and/or replace battery Blank display Possible dead battery Check and/or replace battery Laser doesn t work (1) Low or dead battery (1) Replace battery (2) Ambient temperature (2) Use in area with lower ambient above 40 C (104 F) temperature ERR Possible damage Contact your distributor by EMF CE Certification This instrument conforms to the following standards: EN50081-1:1992, Electromagnetic Emissions EN50082-1:1997, Electromagnetic Susceptibility Tests were conducted using a frequency range of 80-1000 MHz with the instrument in three orientations. The average error for the three orientations is ±0.82 C (±1.48 F) at 3 v/m throughout the spectrum. However, between 234 MHz and 684 MHz at 3 V/m, the instrument may not meet its stated accuracy. 10

Some Noncontact Thermometer Uses Electrical/Industrial Industrieanwendungen Électricité-Méchanique Uso electromecánico Industrial Manutenção Elétrica e Industrial Automotive & Diesel KFZ-Instandesetzung und Wartung Vehicules (essence et diesel) Automotriz y Diesel Automotive e Diesel Food Safety Lebensmittelüberwachung Hygiène alimentaire Seguridad en Alimentos Segurança de Alimentos Pereciveis

Oakton Instruments