Title Broad Range Magnetic Spectrograph. Author(s) Matsuki, Seishi; Ogino, Kouya; Saka.

Similar documents
TitleScattering Chamber for Three Body N.

Author(s) Okihana, Akira; Fujiwara, Noboru; Y.


Minicourse on Experimental techniques at the NSCL Fragment Separators

TitleA 31 cm Model Superconducting Cyclo.

A Comparison between Channel Selections in Heavy Ion Reactions

Title to the Late Professor Yoshiaki Uemu.

Magnetic Separator for light RIB production

ICTP-IAEA Joint Workshop on Nuclear Data for Science and Technology: Medical Applications. 30 September - 4 October, 2013

Light ion recoil detector

Progress in measuring GMR in unstable nuclei: Decay detector calibration and inverse reaction experiment. J. Button, Y.-W. Lui, and D.H.


X-Y Position - t. Rotating Table Brass Collimator. Secondary (Exit Aperture) Target 1.0 m 1.5 m 1.5 m

Investigation of the nuclear structure of 17 O at high excitation energy with five-particle transfer reactions


Developments of the RCNP cyclotron cascade

Upstream Polarimetry with 4-Magnet Chicane

Cross section measurements of the elastic electron - deuteron scattering

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Author(s) Mukoyama, Takeshi; Sarkadi, Citation University (1987), 64(5-6):

PHYSICAL REVIEW C 70, (2004)

Ion Implanter Cyclotron Apparatus System

Angular Correlation Experiments

Measurements of the D + D Reaction in Ti Metal with Incident Energies between 4.7 and 18 kev

The Configuration of the Atom: Rutherford s Model

THE SUPER-FRS PROJECT AT GSI

HiRA: Science and Design Considerations

Deflection of a particle beam by a bending magnet


LASER-COMPTON SCATTERING AS A POTENTIAL BRIGHT X-RAY SOURCE

Title Counter Cooled at Low Temperatures. Author(s) Kishimoto, Shunji; Isozumi,

I. 2. Reduction of the Gamow-Teller Matrix Element for the β-decay in 70 Ga- 70 Zn by the 35-MeV (p,n) Reaction on 70 Zn

An Introduction to the Ion-Optics of Magnet Spectrometers

Neutron detection efficiency from the 7 Li(p,n) reaction (R405n)

Author(s) Isozumi, Yasuhito; Takahashi, Norit. Citation University (1992), 69(5-6):

arxiv:nucl-ex/ v1 21 Jun 2001

The heavy-ion magnetic spectrometer PRISMA

Assembly and test runs of decay detector for ISGMR study. J. Button, R. Polis, C. Canahui, Krishichayan, Y. -W. Lui, and D. H.

Alpha inelastic scattering and cluster structures in 24 Mg. Takahiro KAWABATA Department of Physics, Kyoto University

σx=2.5cm, slpx =33mrd

Nuclear Reactions A Z. Radioactivity, Spontaneous Decay: Nuclear Reaction, Induced Process: x + X Y + y + Q Q > 0. Exothermic Endothermic

Differential Cross Section Measurements in Ion-molecule Collisions

FIRST NUCLEAR-ASTROPHYSICS EXPERIMENTS WITH HIGH-INTENSITY NEUTRONS FROM THE LIQUID-LITHIUM TARGET LiLiT

Pursuing mass resolving power of 10 6 : Commissioning of IGISOL 4

Studies on 3D Fusion Reactions in TiDx under Ion Beam Implantation

C A SPECTROMETER FOR MEASURING INELASTIC SECONDARIES FROM 200 GeV Ie, p-p COLLISIONS. T. O. White National Accelerator Laboratory

The scanning microbeam PIXE analysis facility at NIRS

Light element IBA by Elastic Recoil Detection and Nuclear Reaction Analysis R. Heller

in2p , version 1-28 Nov 2008

Received October 7, 1963

MARS status report for : Development of rare isotope beams of 25 Si, 6 He, 9 Li, 23 Si, and 22 Si

I. 1. Nuclear Structure Study of 50 Mn by Charge-exchange (p,n) Reaction on 50 Cr

Professor Yoshiaki Uemura)

Observation of the Giant monopole resonances in the Sn isotopes via (α,α ) reactions at 400 MeV at RCNP - Latest results and implications -

LASER SPECTROSCOPIC STUDIES OF NEUTRON-DEFICIENT EUROPIUM AND GADOLINIUM ISOTOPES

KEK isotope separation system for β-decay spectroscopy of r-process nuclei

3-D MEASUREMENT OF THE NSCL POSITION-SENSITIVE GAMMA RAY DETECTOR ARRAY

Atomic and Nuclear Physics

Measurements of liquid xenon s response to low-energy particle interactions

IN-BEAM COMMISSIONING OF A RECOIL MASS SPECTROMETER

PROTON-PROTON FEMTOSCOPY AND ACCESS TO DYNAMICAL SOURCES AT INTERMEDIATE ENERGIES

DSAM lifetime measurements for the chiral bands in 194 Tl

Nuclear Reactions Part III Grigory Rogachev

C In other study groups large spark-chamber magnets have been 1 2 These magnets are to be used as triggered ''bubble chambers"

An option of «UCN pump» for ESS. V.V. Nesvizhevsky. Institut Max von Laue Paul Langevin, 71 av. des Martyrs, Grenoble, France.

The Magnetic Recoil Spectrometer (MRSt) for time-resolved measurements of the neutron spectrum at the National Ignition Facility (NIF)

Low Energy Nuclear Fusion Reactions in Solids

TitleGravitational Effect on Internal Co. Author(s) Mukoyama, Takeshi; Katano, Rintaro.

M2 TP. Low-Energy Electron Diffraction (LEED)

ELECTRON IMPACT IONIZATION OF HELIUM [(e,2e) & (e,3e)] INVESTIGATED WITH COLD TARGET RECOIL-ION MOMENTUM SPECTROSCOPY

A measurement of the air fluorescence yield

Status of the MAGIX Spectrometer Design. Julian Müller MAGIX collaboration meeting 2017

Method of active correlations in the experiment 249 Cf+ 48 Ca n

First two energy levels in 15 F

Coulomb breakup of light composite nuclei. Abstract

Author(s) Tatsuzawa, Ryotaro; Takaki, Naoyuki. Citation Physics Procedia (2015), 64:

Proton-Scattering on (29)Si in Range Ep = MeV*

Response function of the magnetic spectrometer PRISMA

Two-electron photo-excited atomic processes near inner-shell threshold studied by RIXS spectroscopy

RITU and the GREAT Spectrometer

The Giant Monopole Resonance in the Sn Isotopes: Why is Tin so Fluffy?

Elastic Recoil Detection Method using DT Neutrons for Hydrogen Isotope Analysis in Fusion Materials. Abstract

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

STORAGE RINGS FOR RADIO-ISOTOPE BEAMS

Angular Distribution of Neutrons from. by Frank Genevese Physical Review Vol.76, # 9 (Nov 1, 1949) A paper on experiment Paper Club, 22, Feb, 2011

Available online at ScienceDirect. Energy Procedia 71 (2015 ) Yokohama, Kanagawa, Japan

THE mono-energetic hadron beam such as heavy-ions or

Title Hydrogen-Like Ions by Heavy Charged.

The MIT laser driven target of nuclear polarized hydrogen gas

Probing the shell model using nucleon knockout reactions

Study of repulsive three-body force via

Photonuclear Reactions and Nuclear Transmutation. T. Tajima 1 and H. Ejiri 2

DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN THICK MATERIALS

Experimental Study of Stellar Reactions at CNS

What is Spallation???

Author(s) Iwashita, Yoshihisa; Higo, Toshiyas.

High-resolution Study of Gamow-Teller Transitions

Fadei Komarov Alexander Kamyshan

PoS(KAON09)023. Beam Hole Photon Veto For J-PARC K O TO experiment. Yosuke Maeda Kyoto University

Thin Calorimetry for Cosmic-Ray Studies Outside the Earth s Atmosphere. 1 Introduction

Transcription:

Title A Gas Target System for Nuclear Sca Broad Range Magnetic Spectrograph Author(s) Matsuki, Seishi; Ogino, Kouya; Saka Citation Bulletin of the Institute for Chemi University (1985), 63(1): 40-46 Issue Date 1985-03-30 URL http://hdl.handle.net/2433/77091 Right Type Departmental Bulletin Paper Textversion publisher Kyoto University

Bull. Inst. Chem. Res., Kyoto Univ., Vol. 63, No. 1, 1985 A Gas Target System for Nuclear Scattering Experiments with Broad Range Magnetic Spectrograph Seishi MATSUKI*, Kouya OGINO**, and Naoki SAKAMOTO*** Received February 9, 1985 A gas target system for nuclear scattering experiments with broad range magnetic spectrograph was developed. The system consists of a cylindrical-type gas target chamber and double slits one of which was set on the rotating table in a scattering chamber. The rear slit was the entrance aperture itself of the broad-range magnetic spectrograph. The whole system was successfully checked by comparing the yields of protons from 12c(p,p') scattering in gas target with in soild target. The system details and its performance are described. KEY WORDS: Gas Target/ Nuclear Scattering/ Magentic Spectrograph/ I. INTRODUCTION Broad-range magnetic spectrographs have been extensively used recently for precise measurements of nuclear reactions. Recent development of high-resolution magnetic spectrograph enabled us to measure reaction products with an accuracy of 0.1%-0.01% energy resolution. In order to extend such precise measurements to nuclei of non-solid state such as rare gas, it is important to develop a gas target system which should be well suited for use with magnetic spectrograph, maintaining still a good energy resolution of the spectrograph. Usually double slits (two apertures in parallel planes) are used for gas target to limit the effective target volume, resulting thus not a point target, but a line target'. The double slit system can be also used for broad-range magnetic spectrograph. Since, however, the magnetic spectraograph system, which usually consists of a couple of quadrupole and dipole magnets, has its own entrance aperture, this aperture should be used for the rear slit of the double slit system. We have developed such a double-slit gas-target system used for the magnetic spectrograph equipped to the FM cyclotron of the Institute for Nuclear Study, University of Tokyo. The gas target system has been successfully used for many experiments with various Kr and Ar isotopic gas targets.2-7 In this note the system details and its performance are described. II. APPARATUS The gas target chamber used is of cylindrical-type made of stainless steel with 10 cm diameter. Havar foils of 2.5,um thickness were used for both the beam entrance * f~*ff*.: Laboratory of Nuclear Reaction, Institute for Chemical Research, Kyoto University, Kyoto. ** M--t: Department of Nuclear Engineering, Kyoto University, Kyoto. *** f *A ': Department of Physics, Nara Women's University, Nara. ( 40 )

--. -- A Gas Target System for Nuclear Scattering Experiments and exit windows and also for the detection window of outgoing particles. The Havar foils were glued with epoxy-resin (araldite) on the stainless steel chamber and the glued area was covered with a thin brass sheet; this cover prevented the glued area of Harvar foils from directly pulled outside by gas pressure, thus enabling the gas pressure to keep higher up to 500 mmhg. Inside the gas-target chamber, three lead blocks are inserted to reduce the inner voulme of the chamber, thus enabling the use of the chamber efficiently for rare enriched isotopes as shown in Fig. 1. B eam duct gasso" tar et F-slit 410# Faraday cupqi:\ A Scattering chamber B-slit 050cm Fig. 1. Schematic plane view of the gas target system. On the rotating table in the scattering chamber, two slits of 2 mm (F-slit) and 4 mm (B-slit) apertures, respectively, were set just in front of the window foil of the gas target chamber for the front slit as seen in Fig. 1. The narrow slit (F-slit) was used at forward angles to get better energy resolution than with the other slit of 4 mm wide (B-slit). The slit was made of 7 mm thick tantalum and the paths from the front slit to the inner wall of the scattering chamber were covered with 7 mm thick brass sheets to reject the outgoing particles entering into the spectrograph through this area. A defining slit in front of the quadrupole magnet of the magnetic spectrograph') and the front slit on the rotating table define the solid angle of the magnetic spectrograph and also the line source area of the gas target. The distance between the front slit (on the rotating table) and the entrance slit on the spectrograph is 50 cm. The effective apertures of the spectrograph are 1.47 cm in horizontal and 6.00 cm in vertical, respectively8). The effective length of the target is thus about 0.45 cm, and 0.90 cm, for F and B slits, respectively. The gas handling system is shown in Fig. 2. To reduce the volume in the handling system, stainless steel pipes of 1 mm inner diameter were used to connect between valves, vacuum gauges and others. Since Kr gas can be solidified at liquid N2 temperature, a resevoir made of stainless steel was incorporated between the gas ( 41 )

S. MATSUKI, K. OGINO, and N. SAKAMOTO GasLl target nnto Gauge pump ScatteringValve chamber/1 I Reservoir for cooling Kr gas Kr gas Fig. 2. Gas handling system especially designed for the Kr gas which was cooled by liquid N2 and solidified to compress a small quantity of the enriched isotopic gas. target and the Kr gas vessel to cool and solidify the Kr gas. This function worked well and enabled us to use efficiently a small quantity of enriched isotopes. III. PERFORMANCE AND DISCUSSION In order to know the solid-angle dependence on the detection angle and energy resolution of the detected particles, elastic and inelastic scattering of 52 MeV protons from 12C were measured with the system; especially the yields from the solid 12C target and from the CH, gas target were compared with each other. The thickness of the solid 12C taregt was about 2 mg/cm2 and the pressure of CH4 gas in the target chamber was about 300 mmhg. The following formula was used in the evaluation of cross sections in the laboratory system with gas target;') (dalds2)y iab. sin 8 nng where n, N, Y and 0 are total number of bombarding particles, number of target nuclei per unit volume, the yield of scattered particles detected by focal-plane counter system and the detection angle of particles in the laboratory system, respectively. The factor G is the effective "G-factor", giving the geometrical dependence of the effective solid angle subtended by the double slit system. Analytical expressions of the G factor for various aperture geometry have been evaluated by a number of authors1m up to the fourth order in 1/R, whree Ro is the distance from the center of the target to the rear aperture. Schematic diagram in the present aperture system is shown in Fig. 3. With the parameters given in the figure, the factor G is given by9) a 0l) a(2) G = Goo[1-+-40+-41+-42+...], where a ( 42 ) a

b a A Gas Target System for Nuclear Scattering Experiments 2b2 REAR APERTURE ok, APERTURE;.. ^ FRONTp/~v2 2b, ~1 I eeam/i /Effec tive ftarg etlengtb Fig. 3. Double slit geometry used in the present gas target system. 46'621 G ao Rh 0 _1 cos' 0b2_(bi+bz)_1 12-3 sin2 0Ro2h28 Ro dl_1 cos 8 12_14l 3 sin 018/4Roll} 1 (bi +bz) 4, 6 h2 and a and '(") are the cross sections at 0 and the n-th derivative of a at 8, respectively. In the present system, the first term do is less than 0.2% of the zeroth- Ex(MeV) _ 0.0 4.43 1029.63 ea^ Solid o0^ Gas 0 ro 10 Gz10 a _ 1 Fig. 4. I I I I I I I i 0 20 40 60 80 elab(deg.) Angular distributions of protons from the 86Kr(p, p')86kr scattering leading to the Ot, 21" and 3i states of l2c. (`3)

v m S. MATSUKI, K. OcuNo, and N. SAKAMOTO order term Gao, so that up to 40 is enough to take into account normally, consistent with the experimental result as shown below. The angular distributions of protons leading to the ground, the first (2+, 4.43 MeV) and the third excited (3-,9.63 MeV) state of 12C are shown in Fig. 4, where both the data taken with solid 12C target and with CH4 gas target are shown together for comparison. As seen in the figure, the cross sections with the gas target are in good agreement with those with solid target, justifying the procedure to evaluate cross sections with the above formula. Typical momentum spectrum of protons from the 86Kr(p,p') scattering is shown in Fig. 5. The overall energy resolution for the elastic peak was about 130 kev at 4x10 86K r(p,p') "Kr ' + 7 NU Epr 51.9 MeV~ a N q U1ro 9 1=42.5 deg. vi 3x103 C C ro r u g 2x 10+ + N.7 C or;;,-; OM O 1x103o- N 0 1 100200300 III Channel number Fig. 5. Typical momentum spectrum of protons from the 86Kr(p,p')86Kr scattering measured in the present gas target system. 30. This value is larger than that in the usual solid target, which is typically 80 kev. The most important contribution to the spread of the energy resolution is due to the finite line target in the gas target experiment. This can be seen in the following analysis; in the first-order theory of the beam transport, each element of beam transport and particle analysis system is expressed by a transfer matrix.") The effect of the finite (line) target volume is also expressed by a transfer matrix which transforms the incident particle vector into a scattered particle one. The coordinate system of this transfer is shown in Fig. 6 where 0 is the detection angle of particles and coincides with the angle of the magnetic spectrograph. From this figure the vector of the incoming particle x1 is transfered to the scattered one x2 as11) Cx2/( cos 0 S cosrxll~ssin 1)I\xiJ+0 fi/i x20 (44)

A Gas Target System for Nuclear Scattering Experiments Z\ N Xi X2 v~3, m rq X1 x C O S'~ X2I Fig. 6. Geometry of the scattered particles in the line source of gas target. (x1, xi) and (x2, xz) represent the horizontal components of the position and angular divergence of the incident and scattered beam, respectively. where S is the effective length of the target volume. Since S is inversely proportional to sin 8, the overall width dx2 which contributes to the target volume is constant determined by the acceptance angle of the double-slit system. As described before, the effective target length is 0.45 cm for the F-slit system. Since a beam spot size of 3 mm diameter on the solid target gives 70 kev contribution to the energy spread of the outgoing particles in this magnetic spectrograph,8) the effective target length produces about 105 kev spread. On the other hand the energy spread of the inicdent beam is estimated to be 50 kev (0.1 %). Other sources of the energy spread are the energy loss of the incident beam in the gas target and the energy straggling of the incident beam due to Harvar foils (entrance and detecting foils). These contributions are estimated to be totally 50 kev. Thus the overall energy resolution obtained in the experiment is consistent with the estimation of several sources for finite resolution. IV. CONCLUSION A gas target system consisting of the cylindrical gas chamber and double-slits, rear of which is the entrance aperture itself of the magnetic spectrograph, was con-. tructed and has been successfully used for many experiments.2-7) Optimum energy resolution obtained in the actual scattering experiment was about 130 kev, being tolerable value compared with the resolution of 70-80 kev in the solid target experiment. This resolution was found to be mainly due to the effective target length. ( 45 )

S. MATSUKI, K. OGINO, and N. SAKAMOTO If the spread of the target length is not so large compared to the normal beam in the solid target (about 1.5 times wider than that of normal beam in the present case), the additional spread of the energy resolution should be tolerable in the actual experiments. It is noted therefore that such a gas target system could also be usable for the higher-resolution magnetic spectrometers which give almost 0.02% energy resolution routinely at 50-100 MeV incident beam energieslz> ACKNOWLEDGMENTS The authors would like to thank Dr. T. Tanabe, Dr. M. Yasue, Mr. Y. Kadota, and Mr. Y. Saito for valuable suggestions and kind help throughout the experiments. REFERENCES (1) G. Breit, K. Thaxton and L. Eisenbud, Phys. Rev. 55, 1018 (1939). (2) S. Matsuki, N. Sakamoto, K. Ogino, Y. Kadota, S. Hayashi, T. Tanabe, M. Yasue, H. Yokomizo and S. Kubono, Proceedings of the INS Sysmposium on Nuclear Collectivity, edited by Y. Shida (Tokyo, 23-25 Sep. 1976) p. 414. (3) S. Matsuki, N. Sakamoto, K. Ogino, Y. Kadota, Y. Saito, T. Tanabe, M. Yasue and Y. Okuma, Phys. Lett., 72B, 319 (1978). (4) N. Sakamoto, S. Matsuki, K. Ogino, Y. Kadota, T. Tanabe and Y. Okuma, Phys. Lett., 83B, 39 (1979). (5) S. Matsuki, N. Sakamoto, K. Ogino, Y. Kadota, T. Tanabe and Y. Okuma, Nucl. Phys., A- 370, 1 (1981). (6) S. Matsuki, K. Ogino, Y. Kadota, N. Sakamoto, T. Tanabe, M. Yasue, A. Yokomizo, S. Kubono and Y. Okuma, Phys. Lett., 113B, 21 (1982). (7) T. Higo, S. Matsuki, K. Ogino, Y. Kadota, N. Sakamoto and T. Tanabe, to be published. (8) K. Yagi, Nucl. Instr. Meth. 31, 173 (1964); K. Yagi, H. Ogawa, Y. Ishizaki, T. Ishimatsu, J. Kokame and K. Matsuda, Nucl. Instr. Meth. 52, 29 (1976). (9) E. A. Silverstein, Nucl. Instr. Meth., 4, 53 (1959). (10) See for example, D. L. Hendrie, Nuclear Spectroscopy and Reactions, Part A, edited by J. Cerny (Academic Press, New York and London, 1974), p 366, and references cited therein. (11) See Ref. 10) for the definitions of the parameters used. (12) H. Ikegami, S. Morinobu, I. Katayama, M. Fujiwara and S. Yamabe, Nucl. Instr. Meth., 175, 335 (1980). ( 46 )