Application of Density Meters to Liquid Hydrocarbon Measurement

Similar documents
Guidelines for the Selection and Operation of Provers with Micro Motion ELITE Coriolis Flow Meters

Manual of Petroleum Measurement Standards Chapter 5 Metering

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG

Uncertainty of Coriolis-Based LACT Units

Smith Meter microload.net

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals

NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland

PRACTICAL CONTROL OF DYNAMIC METERING SYSTEM AND DATA ACQUISITION

Rocky Mountain Measurement Seminar Denver August 20, 2015 Coriolis Meters

FLOW MEASUREMENT VERIFYING YOUR VALUE Small Volume Provers

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT. FINAL DRAFT: October 25, 2010 Page 0

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Fine Tuning Coriolis Flow Meter Calibrations Utilizing Piece- Wise Linearization

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

ALASTAIR MCLACHLAN Applications Cameron

Corrections related to operation and calibration of liquid flow meters NFOGM Temadag 2016 Morten Marstein, FMC Kongsberg Metering

Applied Fluid Mechanics

AN 8-PATH ULTRASONIC MASTER METER FOR OIL CUSTODY TRANSFERS

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

The Uncertainty of a Waterdraw Calibration vs. Gravimetric Calibration on Small Volume Provers

Process Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018

Fundamentals of Flow Metering

Flow Management Devices, LLC An ISO 9000:2008 Certified Company

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Flare/Vent Metering. Lex Scheers. If you can t t measure, you can t t manage. Advanced Production Management

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Large Rocket Engine Environments

Public Outreach Meeting. Proposed Revision of Onshore Orders 3, 4, and 5

KNOWLEDGE

Reprinted from February Hydrocarbon

ULTRASONIC FLOW MEASUREMENT WITH INTEGRATED TEMPERATURE MEASUREMENT COMPENSATION

Custody Transfer Measurement and Calibration Round Robin Testing for Natural Gas with Coriolis Meters

Flow Monitoring Technologies in Oil and Gas. Don Ford, Technical Specialist Spartan Controls Ltd.

EXPERIMENT NO. 4 CALIBRATION OF AN ORIFICE PLATE FLOWMETER MECHANICAL ENGINEERING DEPARTMENT KING SAUD UNIVERSITY RIYADH

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

Annex A - Examples of Shore Tank and Marine Vessel Tank Calculations

INTERNATIONAL STANDARD

NEW VSL Conditioning plate!

Orifice Plate. Stainless Steel. Flow Data. Herz Valves UK Ltd.

Understanding the Uncertainty when Using a Type Coefficient for Temperature Corrections of a Coriolis meter. Dean M. Standiford Emerson-Micromotion

Given Find Water Properties

SELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

A Powerful New Diagnostic Tool for Transit Time Ultrasonic Meters page 1. A Powerful New Diagnostic Tool for Transit Time Ultrasonic Meters

POWER UNDERSTANDING MEASUREMENT UNCERTAINTY IN DP FLOW DEVICES

Chapter 5. Mass and Energy Analysis of Control Volumes

Annubar Primary Element Flow Calculations

Determining Liquid Capacity 4 th Annual Pipeline Knowledge Retention Chris Sonneborn November 7, 2013

Product Discontinued

Compressible Gas Flow

KNOWLEDGE. Mass Flow Measurement Accuracy in Process Industries MICRO MOTION WHITE PAPER. .micromotion.com. How Accurate is Accurate?

Flow Measurement in Pipes and Ducts COURSE CONTENT

Given Find Water Properties

FLOW MEASUREMENT INC 331 Industrial process measurement 2018

TS02 - Pre-Instructional Survey

Describe Coriolis Mass Flowmeters

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

9. Pumps (compressors & turbines) Partly based on Chapter 10 of the De Nevers textbook.

The Expansibility Factor Equations in ISO and ISO : Do They Deliver What They Promise?

Anyone who observes. By Jesse Yoder

Turbine flowmeter and viscosity effects of liquid hydrocarbons

ABB Flowmeters Review of industrial processing flowmeters

Use N 1, if sizing the valve for a flow rate in volumetric units (gpm or m 3 /h).

ABSTRACT 1. INTRODUCTION 1 2. THEORETICAL BACKGROUND 3 3. POSITIVE DISPLACEMENT PROVERS MEASUREMENT PRINCIPLE CALIBRATION PROCEDURE 6

PROCEEDINGS American School of Gas Measurement Technology 2003 PROCEEDINGS. PAGE xxv AMERICAN SCHOOL OF GAS MEASUREMENT TECHNOLOGY

ELECTRONIC FLOWMETERS FOR THERMAL ENERGY MEASUREMENT. By Dr. Crainic Monica Sabina

APPLICATION OF DENSITOMETERS TO LIQUID MEASUREMENT Class #

Applied Fluid Mechanics

98 Series Backpressure Regulators and Relief Valves

close to performances of the turbine gas meters designed for custody transfer measurements.

The MMs are 4 KRAL screw meters, normally permanently installed in the BEV test rig as secondary working standards.

Pressure and Flow Characteristics

Course: TDEC202 (Energy II) dflwww.ece.drexel.edu/tdec

Examining Density vs. Refractive Index Technologies For Inline Concentration Measurements

Volumetric Flow Measurement

Uncertainty in Gas Density. Measured and Calculated

Cooling Water Flow Regulator

An Essential Requirement in CV Based Industrial Appliances.

Accurate Flow Measurements in Changing Process Conditions

MODEL : TX Series (Nom. sizes 15mm to 400mm)

Comparison of discharge measurements - Thermodynamic to US Clamp- On, stationary US and Needle Opening Curve

ISO 9906 INTERNATIONAL STANDARD. Rotodynamic pumps Hydraulic performance acceptance tests Grades 1 and 2

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

DESIGN AND PERFORMANCE OF THE CONVERGING-DIVERGING VORTEX FLOWMETER

Flow Measurement in Pipes and Ducts COURSE CONTENT

Utilizing Instrumented Stand Pipe for Monitoring Drilling Fluid Dynamics for Improving Automated Drilling Operations

KNOWLEDGE. Allow Smart Meter Verification to Reduce your Proving and Proof-Test Costs. Abstract. Introduction

Spirit IT exlerate Measurement supervisory software

Mechanical Engineering for Renewable Energy Systems. Wind Turbines

CVE 372 HYDROMECHANICS EXERCISE PROBLEMS

Using the Coriolis Acceleration to Design a Digital Mass Flow Meter

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Flow Measurement in Pipes and Ducts

Electronic Gas Flow Computer Smith Meter microflow.net Gas. Calculations. The Most Trusted Name In Measurement

Integral V-Cone Flowmeter VD series

Accumulators Virginia KMP Suction Line Accumulators

REPORT ON API 21.1 EGM STANDARD Brent E. Berry ABB-Totalflow

= A x (t) + B utt), by d{ _-=-=-

Gas Pipeline Hydraulics: Pressure Drop

Transcription:

02/2018 Application of Density Meters to Liquid Hydrocarbon Measurement Written by Dean Minehart, Micro Motion, Inc. www.emerson.com/micromotion

1 Introduction The American Petroleum Institute (API) Manual of Petroleum Measurement Standards (MPMS) Chapter 9 Section 4 provides guidance for online density meter selection/operation, sampling system design and field proving methods. Continuous density measurement may be accomplished with a device located in the main flowing stream or in a slipstream. Density measurement is utilized in both volumetric and mass measurement systems. Volumetric measurement requires the use of density to determine correction factors for temperature and pressure on a flowing liquid. Inferred mass measurement systems require density measurement at meter conditions to determine mass flow. Direct mass measurement systems require online density measurement at a meter prover to determine prover mass and calculate a mass meter factor. 2 Density Meter Selection Proper density meter selection is determined by how a meter will be applied. Density uncertainty requirements for inferred mass measurement system applications is lower than volumetric measurement system applications. This is due to a fact that in inferred mass measurement a density term multiplies by volume to calculate mass. Density is used in volumetric applications with flowing temperature & pressure to compute a combined correction factor that corrects indicated volume to standard conditions. API MPMS Chapter 9 Section 4 provides density measurement uncertainty requirements based on a meter application and the following sections of this document explain how density is used for mass or volumetric measurement of hydrocarbon liquids. 3 Density Meter Installation Density meters can be installed inline (full flow through), directly inserted into a pipeline or in a density by pass loop. Care must be taken to provide a representative sample of the flowing fluid where a density measurement is made. API MPMS Chapter 9 Section 4 provides guidance on how a density meter should be installed depending on an application. Density meters may be installed upstream or downstream of a volumetric flow meter. The recommended installation is downstream of an inferred mass volumetric flow meter. 4 Field Proving Density Meters API MPMS Chapter 9 Section 4 provides guidance on proving density meters against a pycnometer or hydrometer depending on an application. New pycnometer proving guidance requires three consecutive runs (+/- 0.05% repeatability) which represents a change from former API MPMS Chapter 14 Section 6 requirements. Hydrometer proving guidance is new to API MPMS Chapter 9 Section 4 and allows for the use of either a batch proportional composite sample or spot sample. Liquid applications following this proving guidance must be stable at atmospheric pressure and measured volumetrically (e.g. crude oil or refined products). 5 Density Measurement in Net Standard Volume (NSV) Measurement System Calculations NSV is the basis by which liquid volume of crude oils, refined products and some purity LPG is measured. NSV calculations are standardized by API MPMS Chapter 12 Section 2. Density measurement is required to calculate volume correction factors based on RHOb which is defined below. Continuous density meters are applied to volumetric measurement systems. Observed density (RHOobs) is measured online at flowing temperature and pressure. Observed density is corrected to standard conditions (RHOb) which is used to calculate volume correction factors for pressure and temperature. NSV = GSV x CSW NSV - gross standard volume adjusted for S&W (sediment and water). GSV - total fluid measured at standard conditions, including both merchantable crude oil and non-merchantable components such as sediment and water. Volume at standard conditions indicates volume that is adjusted for temperature and pressure effects (e.g. 60 Degrees F/0 psig). CSW - correction factor for S&W (where present) reducing the gross standard volume for non-merchantable content which is equivalent to the merchantable fraction of fluid. Page 2

GSV = IV x CCF IV - uncompensated indicated volume registered by a volumetric flow meter. CCF = MF x CTL x CPL MF - meter factor that compensates an indicated volume for meter inaccuracy determined by meter proving. CTL - correction for temperature on liquid-density dependent factor to compensate for the temperature of the measured liquid. CPL - correction for pressure on liquid-density dependent factor to compensate for the pressure of the measured liquid. CTL&CPL - calculations based on API MPMS Chapter 11.1/11.2 or applicable standards using: TWA, PWA & RHOb TWA/PWA - temperature/pressure flow weighted average RHOb - density of liquid at 60 degrees F/0 psig or other standard conditions; calculated from RHOobs (API MPMS Chapter 12 Section 2, Part 1, Appendix B-Liquid Density Correlation) RHOobs - density of liquid at observed temperature/ pressure CSW = 1-(S&W%/100) CSW - value representing the merchantable fraction of the gross standard volume. S&W% - percentage of S&W. 6 Density Measurement in Direct Mass Measurement System Calculations Mass measurement techniques (direct or inferred mass) are typically applied to light hydrocarbons (0.350-0.689 relative density at 60 Degrees F.). Direct mass measurement is achieved by using a Coriolis flow meter and programming the transmitter to output pulses per unit mass (pulses per pound). Coriolis flow meter installations should follow the guidance provided in API MPMS Chapter 5 Section 6. Direct mass meters require that a meter factor be derived by mass proving. This requires the addition of an online density measurement at prover conditions (prover volume x density = mass). An Inferred Mass Prover Density Measurement section of this paper (below) provides more details on requirements for proper prover density measurement. API MPMS Chapter 14 Section 7 provides an equation for direct mass measurement: Qm = Im m x MF m Qm = mass flow Im m = indicated Coriolis meter mass MF m = meter factor for Coriolis meter mass 7 Density Measurement in Inferred Mass Measurement System Calculations Inferred mass measurement is achieved by using a volumetric flow meter in conjunction with an online density measurement at flowing conditions. Volumetric flow meters should be installed with guidance from an appropriate section of the API MPMS Chapter 5 depending on the meter technology selected (e.g. API MPMS Chapter 5 Section 3 for turbines). Coriolis flow meters are sometimes used for volumetric flow measurement in inferred mass measurement systems by configuring the flow meter transmitter to output pulses per unit volume (e.g. pulses per barrel) and measuring online density with a separate density meter installed in a bypass loop. Page 3

API MPMS Chapter 14 Section 7 provides an equation for inferred mass measurement: Qm = IV x MFv x ρ f x DMF Qm = mass flow IV = indicated meter volume at operating conditions MF v = volumetric meter factor ρ f = indicated density at operating conditions DMF = density meter factor Inferred mass density measurement guidance is provided by API MPMS Chapter 9 Section 4. Density meter loops (Figure 1.) are generally one-inch pipe work or smaller which means the density meter is installed in a bypass loop from the main flow line. Maintaining a representative sample (composition, temperature and pressure) in the density bypass loop of the flow through the volumetric flow meter can be difficult. Insulation should be applied to density meter bypass loop piping. Differences in process conditions at the flow and density meters can provide additional mass measurement uncertainty versus a direct mass measurement. 8 Inferred Mass Prover Density Measurement Density measurement is required on a displacement meter prover for mass proving. Density meters are often placed on a piston prover s outlet across a valve or other restriction to create flow through the density loop. Density loops should include pressure and temperature measurements at the density meter and pycnometer outlets to ensure equal process conditions when a pycnometer sample is pulled. Regardless of where a density loop is located, a density meter factor (DMF) is required. T TW P T TW P DT PYC T TW P FI Figure 1.-Typical Inferred Mass Measurement Density Page 4

9 Conclusion Density meter selection, installation, operation and maintenance guidance is provided in the API MPMS Chapter 9 Section 4. Density meter uncertainty requirements and installation requirements are determined by a meter s application. Inferred mass measurement density uncertainty requirements are lower than volumetric measurement applications. Density meter factors are calculated based on field proving procedures outlined in API MPMS Chapter 9 Section 4 for pycnometer or hydrometer methods. Density measurement is necessary for input to volumetric and mass measurement system calculations as outlined above and impacts the overall measurement uncertainty. Emerson has application expertise and a range of density measurement solutions to address volumetric and mass measurement application requirements. Please contact a local Emerson Automation Solutions sales office for more information. Emerson Automation Solutions 7070 Winchester Circle Boulder, CO USA 80301 T +1 303 527 6277 F +1 303 530 8459 www.emerson.com 2018 Micro Motion, Inc. All rights reserved.