Determination of iopromide in environmental waters by ion chromatography-icp-ms

Similar documents
Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Determination of Pharmaceuticals in Environmental Samples

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Application Note. Abstract. Authors. Environmental

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

ENVIRONMENTAL analysis

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Agilent ICP-MS Journal October 2012 Issue 51

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Agilent 6460 Triple Quadrupole LC/MS System with an Agilent 1290 Infinity LC For Multi-Plant Growth Regulator Analysis in Grapes

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes Application

Analysis of Phthalates in Body Wash using Solid-Supported Liquid-Liquid Extraction

Department of Civil and Environmental Engineering, Stanford University, 473 Via Ortega, Stanford, California 94305, United States

A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Supporting Information

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Determination of Chlorinated Acid Herbicides in Soil by LC/MS/MS Application Note

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Determination of trace anions in concentrated hydrofluoric acid

High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes

LC/MS/MS of Fungicides and Metabolites in Orange Juice with Agilent Bond Elut Plexa and Poroshell 120

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Rapid determination of five arsenic species in polished rice using HPLC-ICP-MS

LC/MS/MS of Fungicides and Metabolites in Apple Juice with Agilent Bond Elut Plexa and Poroshell 120

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

British American Tobacco Group Research & Development. Method - Determination of ammonia in mainstream smoke

Trace Level Determination of Bromate in Ozonated Drinking Water Using Ion Chromatography

LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Quantitative analysis of mitragynine in human urine by high performance liquid chromatography-tandem mass spectrometry

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

The Quantitation and Identification of Coccidiostats in Food by LC-MS/MS using the AB SCIEX 4000 Q TRAP System

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Validation of New VPH GC/MS Method using Multi-Matrix Purge and Trap Sample Prep System

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Supporting Information. Detection and Occurrence of Chlorinated By-products of Bisphenol A, Nonylphenol and

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

Method Development in Solid Phase Extraction using Non-Polar ISOLUTE SPE Columns for the Extraction of Aqueous Samples

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Luminescence transitions. Fluorescence spectroscopy

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

SAMHSA-Compliant LC/MS/MS Analysis of Phencyclidine in Urine with Agilent Bond Elut Plexa PCX and Agilent Poroshell 120

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

Benzoylecgonine in Urine by SAMHSA GC/MS

Determination of Hormones in Serum by LC/MS/MS Using Agilent Bond Elut Plexa SPE

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Analysis of Cannabinoids and Amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source. Application.

A New Polymer-based SPE Sorbent to Reduce Matrix Effects in Bioanalytical LC-MS/MS

Application Note. Authors. Abstract. Introduction. Environmental

Determination of Alkaloids in Goldenseal Using Agilent Bond Elut Plexa Solid Phase Extraction Sorbent for Cleanup and HPLC-DAD Analysis

Highly sensitive quantitative estimation of genotoxic impurities from API and drug formulation using LC/MS/MS

ANALYSIS OF PERCHLORATE IN DRINKING WATER, GROUND WATER, SALINE WATER, SOIL, AND BIOTA BY LC/MSD

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

Determination of urea in ultrapure water by IC-MS/MS

Determination of 24 PAHs in Drinking Water

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Application Note GCMS-01 Comparison of Ionization Techniques for the Analysis of Trace-Level Pyrethroid Insecticides by GC-MS/MS

Transcription:

Determination of iopromide in environmental waters by ion chromatography-icp-ms Application note Environmental Authors Armando Durazo, Tarun Anumol, and Shane A. Snyder Department of Chemical & Environmental Engineering and the BIO5 Institute, University of Arizona Tucson, AZ, USA Abstract The determination of iopromide in environmental waters has been accomplished using an Agilent 7700x ICP-MS coupled to an Agilent 1260 LC. The use of High Matrix Introduction (HMI) technology allows for prolonged operation with a sodium hydroxide (NaOH) eluent, and the Octopole Reaction System (ORS3) in helium gas mode reduces polyatomic interferences on iodine (m/z 127).

Introduction Iopromide is an iodinated contrast medium (ICM), which is used to image internal body organs and blood vessels by x-ray or computerized tomography (CT) scan. Iopromide is generally given to patients in g/l concentrations and is excreted within 24 hours in the patient s urine [1]. It is very hydrophilic (log K ow = 2.33) and non-ionic, properties that make it quite persistent in the environment. The molecular formula of iopromide is C 18 H 24 I 3 N 3 O 8 and its chemical structure is shown in Figure 1. Most analytical methods developed for iopromide and other ICMs involve the use of LC coupled to a mass spectrometer, generally a triple quadrupole mass spectrometer [9, 14 17]. Hybrid methods involving ion trap and nuclear magnetic resonance have also been employed. This application note describes the optimized conditions for sensitive and reproducible analysis of sub-ppb levels of iopromide in water extracts, using an Agilent 1260 LC coupled to an Agilent 7700x ICP-MS. With the use of a 500 µl injection volume, we have established a lower method reporting limit (MRL) of 0.1 ppb for iopromide in the diluted methanol extracts in our assay; in theory this corresponds to a lower MRL of 2 ppt in our environmental water samples. Experimental Figure 1. Chemical structure of iopromide Iopromide s presence in surface waters and wastewaters has been widely reported as ranging from a few ng/l to as much as 10 µg/l in sewage treatment plants [2 4]. Furthermore, ICMs are known to be resistant to sewage treatment and studies have shown they are relatively poorly removed by conventional treatment processes [2, 5 7]. Due to its presence and environmental persistence, it has also been suggested that iopromide be used as a potential indicator compound of wastewater contamination [8]. Recent studies indicate that iopromide and other ICMs can form toxic iodinated disinfection byproducts (I-DBPs) during oxidation and disinfection water treatment processes [4, 9, 10]. Certain I-DBPs are known to be several times more toxic than chlorinated and brominated disinfection by-products [11 13] but are, as yet, not regulated by the US Environmental Protection Agency (USEPA) or other regulatory agencies. Environmental water samples were collected at established monitoring points along the rivers and creeks in the state of California, including locations near water treatment plants. The water samples were filtered through 0.7 µm filters and then extracted using an automated solid-phase extraction (SPE) system. 200 mg hydrophilic-lipophilic balance (HLB) cartridges were first preconditioned with 5 ml of methyl tertiary butyl ether (MTBE), followed by 5 ml of methanol and 5 ml of HPLC grade water. 1 L of each sample was then loaded onto a cartridge at a flow rate of 15 ml/ min, after which the cartridges were rinsed with HPLC grade water followed by drying with nitrogen gas for 30 minutes. Adsorbed analytes were then eluted into 15 ml graduated conical tubes with 5 ml of methanol followed by 5 ml of 10/90 (v/v) methanol/ MTBE solution. The eluent was then evaporated to a total volume less than 100 µl under flowing nitrogen followed by reconstitution to 1.0 ml total volume using methanol. 50 µl of this extract was then diluted with 950 µl of HPLC grade water to give the final extract used for IC-ICP-MS analysis. These diluted extracts were injected into an Agilent 1260 HPLC coupled to an Agilent 7700x ICP-MS, with an injection volume of 500 µl. The chromatographic separation was performed using a Dionex AG16 4 x 50 mm guard column followed by a Dionex AS16 4 x 250 mm analytical column. A gradient elution from 2 90 mm sodium hydroxide (NaOH) was established, 2

using a binary gradient consisting of reagent water (A) and 100 mm NaOH (B) with a constant flow rate of 1.0 ml/min. Gradient parameters were as follows: 2% B for 18.5 minutes then increased linearly for 3.5 minutes to 40% B and held for two minutes, finally stepping up to 90% B and holding for six minutes. The gradient returned to 2% B for five minutes at the end of the run, to re-equilibrate the column, giving a total run time of 35 minutes. A 25 second needle wash using 10% aqueous methanol was used following all injections of standards and samples. The Agilent 7700x ICP-MS was operated with HMI sample introduction (0.6 L/min dilution gas, 0.5 L/min carrier gas, sample depth = 9 mm) and in helium collision mode (He flow 3.5 ml/min). Iodine (m/z 127) intensity was monitored in time-resolved analysis (TRA) mode using a 2 second integration time over a 37 minute time window. The use of HMI allows for extended analysis of high matrix samples with minimal matrix deposition in the interface cones, and the use of the He collision cell removes potential polyatomic interferences on masses 127 such as 126 XeH +. A calibration curve for iopromide was prepared using aqueous standards with concentrations of 0.0, 0.1, 1, 10, 100 and 1000 ppb of intact compound (Figure 3). In addition to iopromide, several other iodine containing compounds were detected in our chromatograms, as shown in Figure 4. These unknown species can be quantified based on their iodine content, using compound-independent calibrations (CIC), where the iodine content of an unknown compound is calibrated using the iodine response for a known compound, in this case iopromide. ICP-MS is ideally suited for analysis using CIC, as the high temperature ICP ion source ensures that the elemental response of the target element (iodine in this case) is essentially independent of the compound in which the target element is present. The quantitation of the iodine content in these unidentified peaks is listed in Table 2. Results and discussion Using the method described, we have been able to detect iopromide in all non-zero standards used in our study. The chromatogram obtained for the 0.1 ppb injection is clearly distinguishable from the blank injection (as shown in Figure 2), and the calibration curve is linear over four orders of magnitude (as shown in Figure 3). This concentration range encompasses the levels at which iopromide has been observed in environmental waters including undiluted wastewater effluent. The standards and samples in this report were analyzed during a 24 hour continuous sequence. The results obtained from this sequence are shown in Table 1. The other CCVs analyzed at the end of this sequence all agreed with their predicted values within approximately 10%. 3

Figure 2. Comparison of the iodine chromatograms (m/z 127) obtained from injections of an aqueous blank extract (top) and an aqueous 0.1 ppb iopromide standard (bottom). The retention time of iopromide is 10.1 minutes. Figure 3. Calibration curve (log log) obtained for iopromide. The concentration axis is in ppb iopromide and the calibration points are at 0.0, 0.1, 1, 10, 100, and 1000 ppb of iopromide. Inset table lists calibration standard responses. 4

Table 1. Summary of iopromide concentration determined in all samples measured Sample Conc. (ppb) 007SMPL.d 4/20/2012 2:03 PM Sample SJC1 246.19 008SMPL.d 4/20/2012 2:48 PM Sample LAR Ref 0.14 009SMPL.d 4/20/2012 3:33 PM Sample LAR Eq blank 0.19 010SMPL.d 4/20/2012 4:18 PM Sample LAR 6 2.53 011SMPL.d 4/20/2012 5:04 PM Sample LAR 5 1.97 012SMPL.d 4/20/2012 5:49 PM Sample LAR 4 2.44 013SMPL.d 4/20/2012 6:34 PM Sample LAR 3 1.86 014SMPL.d 4/20/2012 7:19 PM Sample LAR 2 0.57 015SMPL.d 4/20/2012 8:04 PM Sample LAR 1 2.19 016SMPL.d 4/20/2012 8:50 PM Sample Eq blank 0.00 017SMPL.d 4/20/2012 9:35 PM Sample 100 ppb STD 107.23 018SMPL.d 4/20/2012 10:20 PM Sample SGR ref 0.14 019SMPL.d 4/20/2012 11:05 PM Sample SGR 6 32.69 020SMPL.d 4/20/2012 11:51 PM Sample SGR 5b 33.34 021SMPL.d 4/21/2012 12:36 AM Sample SGR 5a 1.68 022SMPL.d 4/21/2012 1:21 AM Sample SGR 5 85.22 023SMPL.d 4/21/2012 2:06 AM Sample SGR 3b 1.13 024SMPL.d 4/21/2012 2:52 AM Sample SGR 3a 108.35 025SMPL.d 4/21/2012 3:37 AM Sample Blank 0.05 Figure 4. Extracted ion chromatogram (m/z 127) of a representative sample indicating the presence of various iodinated compounds in water extracts 5

Table 2. Summary of the concentrations of iodinated compounds (expressed as iodine concentration) measured in all extracts. Note that the results for all compounds including iopromide are expressed as iodine concentration, so the reported values shown for iopromide expressed as iodine are approximately half the actual iopromide concentrations shown in Table 1. Sample Unknown 1 RT 5.2 min Unknown 2 RT 8.5 min Iopromide (as I) Unknown 3 RT 12 min Unkown 4 RT 30 min Data file Acq. date and time Type Sample name Conc. (ppb) Conc. (ppb) Conc. (ppb) Conc. (ppb) Conc. (ppb) 007SMPL.d 4/20/2012 2:03 PM Sample SJC1 268.55 0.24 118.17 5.77 9.64 008SMPL.d 4/20/2012 2:48 PM Sample LAR Ref 1.43 0.23 0.07 0.00 55.55 009SMPL.d 4/20/2012 3:33 PM Sample LAR Eq blank 1.86 0.20 0.09 0.00 0.38 010SMPL.d 4/20/2012 4:18 PM Sample LAR 6 84.23 0.29 1.21 6.16 17.13 011SMPL.d 4/20/2012 5:04 PM Sample LAR 5 98.87 0.39 0.95 7.11 11.95 012SMPL.d 4/20/2012 5:49 PM Sample LAR 4 128.68 0.38 1.17 12.97 13.03 013SMPL.d 4/20/2012 6:34 PM Sample LAR 3 116.40 0.27 0.89 10.21 12.62 014SMPL.d 4/20/2012 7:19 PM Sample LAR 2 156.01 0.22 0.28 12.86 14.87 015SMPL.d 4/20/2012 8:04 PM Sample LAR 1 189.00 0.29 1.05 12.15 22.51 016SMPL.d 4/20/2012 8:50 PM Sample Eq blank 0.28 0.19 0.00 0.00 0.21 017SMPL.d 4/20/2012 9:35 PM Sample 100 ppb STD 0.00 0.15 51.47 N/D 0.11 018SMPL.d 4/20/2012 10:20 PM Sample SGR ref 0.34 0.21 0.07 0.00 0.29 019SMPL.d 4/20/2012 11:05 PM Sample SGR 6 142.49 0.16 15.69 8.46 20.54 020SMPL.d 4/20/2012 11:51 PM Sample SGR 5b 194.45 0.12 16.00 11.20 14.92 021SMPL.d 4/21/2012 12:36 AM Sample SGR 5a 7.27 0.19 0.81 0.37 54.73 022SMPL.d 4/21/2012 1:21 AM Sample SGR 5 326.73 0.10 40.91 11.29 5.66 023SMPL.d 4/21/2012 2:06 AM Sample SGR 3b 24.46 0.28 0.54 3.95 6.56 024SMPL.d 4/21/2012 2:52 AM Sample SGR 3a 322.50 N/D 52.01 11.36 3.14 025SMPL.d 4/21/2012 3:37 AM Sample Blank 0.03 0.23 0.03 0.00 0.18 Conclusions We have successfully quantified iopromide in a series of environmental water extracts using an Agilent 1260 LC coupled to an Agilent 7700x ICP-MS. This experimental arrangement allowed for us to establish an analytical method with a lower method reporting limit (MRL) of 0.1 ppb iopromide in extracts prepared via automated SPE. The use of the HMI interface allowed for an extended (>24 h) analysis to be completed (using nonvolatile eluents) with minimal matrix deposition on the interface cones, and the use of He collision gas mode provides effective removal of polyatomic interferences. Not only does our work confirm and quantitate the presence of iopromide in these environmental samples, it indicates the presence of other iodinated organic compounds in these samples that are likely from anthropogenic sources and may prove to be biologically active. 6

References 1. Steger-Hartmann, T. et al. (2002). Investigations into the environmental fate and effects of iopromide (ultravist), a widely used iodinated x-ray contrast medium. Water Research, 36(1), 266 274. 2. Ternes, T. A. & Hirsch, R. (2000). Occurrence and behavior of x-ray contrast media in sewage facilities and the aquatic environment. Environmental Science & Technology, 34(13), 2741 2748. 3. Carballa, M., et al. (2004). Behavior of pharmaceuticals, cosmetics and hormones in a sewage treatment plant. Water Research, 38(12), 2918 2926. 4. Kormos, J. L., Schulz, M. & Ternes, T. A. (2011). Occurrence of iodinated x-ray contrast media and their biotransformation products in the urban water cycle. Environmental Science & Technology, 45(20), 8723 8732. 5. Drewes, J. E., Fox, P. & Jekel, M. (2001). Occurrence of iodinated x-ray contrast media in domestic effluents and their fate during indirect potable reuse. Journal of Environmental Science and Health Part A Toxic/ Hazardous Substances & Environmental Engineering, 36(9), 1633 1645. 6. Drewes, J. E., et al. (2003). Fate of pharmaceuticals during ground water recharge. Ground Water Monitoring and Remediation, 23(3), 64 72. 7. Snyder, S. A., et al. (2007). Role of membranes and activated carbon in the removal of endocrine disruptors and pharmaceuticals. Desalination, 202(1 3), 156 181. 8. Dickenson, E. R. V. et al. (2011). Indicator compounds for assessment of wastewater effluent contributions to flow and water quality. Water Research, 45(3), 1199 1212. 9. Duirk, S. E., et al. (2011). Formation of toxic iodinated disinfection byproducts from compounds used in medical imaging. Environmental Science & Technology, 45(16), 6845 6854. 10. Schulz, M. et al. (2008). Transformation of the x-ray contrast medium iopromide in soil and biological wastewater treatment. Environmental Science & Technology, 42(19), 7207 7217. 11. Richardson, S. D. et al. (2008). Occurrence and mammalian cell toxicity of iodinated disinfection byproducts in drinking water. Environmental Science & Technology, 42(22), 8330 8338. 12. Richardson, S. D. et al. (2007). Occurrence, genotoxicity, and carcinogenicity of regulated and emerging disinfection byproducts in drinking water: A review and roadmap for research. Mutation Research- Reviews in Mutation Research, 636(1 3), 178 242. 13. Smith, E. M. et al. (2010). Comparison of byproduct formation in waters treated with chlorine and iodine: relevance to point-of-use treatment. Environmental Science & Technology, 44(22), 8446 8452. 14. Putschew, A., Schittko, S. & Jekel, M. (2001). Quantification of triiodinated benzene derivatives and x-ray contrast media in water samples by liquid chromatography-electrospray tandem mass spectrometry. Journal of Chromatography A, 930(1 2), 127 134. 15. Hirsch, R. et al. (2000). A sensitive method for the determination of iodine containing diagnostic agents in aqueous matrices using LC-electrospray-tandem-MS detection. Fresenius Journal of Analytical Chemistry, 366(8), 835 841. 16. Ternes, T. A. (2001). Analytical methods for the determination of pharmaceuticals in aqueous environmental samples. Trac-Trends in Analytical Chemistry, 20(8), 419 434. 17. Vanderford, B. J. et al. (2011). Assessment of sample preservation techniques for pharmaceuticals, personal care products, and steroids in surface and drinking water. Analytical and Bioanalytical Chemistry, 399(6), 2227 2234. 7

www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc. 2012 Published October 3, 2012 Publication number: 5991-1044EN