R&D on Astroparticles Detectors. (Activity on CSN )

Similar documents
Study of GEM-like detectors with resistive electrodes for RICH applications

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

PHOTOELECTRON COLLECTION EFFICIENCY AT HIGH PRESSURE FOR A GAMMA DETECTOR ENVISAGING MEDICAL IMAGING

DARWIN. Marc Schumann Physik Institut, Universität Zürich. Aspera Technology Forum 2010, October 21-22, 2010

The Development of Gaseous Detectors with Solid Photocathodes for Low Temperature Applications

Development of gaseous PMT with micropattern gas detector

Two-phase and gaseous cryogenic avalanche detectors based on GEMs

Advances in the Micro-Hole & Strip Plate gaseous detector

Breakdown limit studies in high-rate gaseous detectors

GEM-based gaseous Photomultipliers for UV and visible photon imaging. Dirk Mörmann Amos Breskin Rachel Chechik Marcin Balcerzyk Bhartendu Singh

Development and preliminary tests of resistive microdot and microstrip detectors

SIGN: A Pressurized Noble Gas Approach to WIMP Detection

PANDA-?? A New Detector for Dark Matter Search

Progress in the Development of Photosensitive GEMs with Resistive Electrodes Manufactured by a Screen Printing Technology

GEM: A new concept for electron amplification in gas detectors

GEM-based photon detector for RICH applications

Direct WIMP Detection in Double-Phase Xenon TPCs

DARK MATTER SEARCH AT BOULBY MINE

PHYS 3446 Lecture #12

Factors Affecting Detector Performance Goals and Alternative Photo-detectors

Particle Energy Loss in Matter

Photon Detector Performance and Radiator Scintillation in the HADES RICH

Ion feedback suppression using inclined MCP holes in a Single-MCP+Micromegas+Pads Detector *

Evaluation and reduction of ion back-flow in multi-gem detectors

Energetic particles and their detection in situ (particle detectors) Part II. George Gloeckler

Two-phase argon and xenon avalanche detectors based on Gas Electron Multipliers

Generic Detector. Layers of Detector Systems around Collision Point

Ionization Detectors

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Lecture # 3. Muhammad Irfan Asghar National Centre for Physics. First School on LHC physics

Recent advances in gaseous imaging photomultipliers

Nuclear Physics Laboratory. Gamma spectroscopy with scintillation detectors. M. Makek Faculty of Science Department of Physics

Gas Electron Multiplier detectors with high reliability and stability. Abstract. Introduction

Pressure effect in the X-ray intrinsic position resolution in noble gases and mixtures

PoS(EPS-HEP2017)074. Darkside Status and Prospects. Charles Jeff Martoff Temple University

Recent advances in gaseous imaging photomultipliers

EEE4106Z Radiation Interactions & Detection

AIRFLY: Measurement of the Air Fluorescence induced by electrons

A proposal to study gas gain fluctuations in Micromegas detectors

Lecture 18. New gas detectors Solid state trackers

Particle Energy Loss in Matter

arxiv:physics/ v2 27 Mar 2001

Radionuclide Imaging MII Detection of Nuclear Emission

arxiv:physics/ v1 3 Aug 2006

RPCs and applications to the Particle Physics

Gamma and X-Ray Detection

3 Gaseous Detectors. Detectors for Particle Physics Manfred Krammer Institute for High Energy Physics, Vienna, Austria

Chapter 4 Scintillation Detectors

arxiv:astro-ph/ v1 15 Feb 2005

Performance study of the ceramic THGEM *

Seminar talks. Overall description of CLAS12 (Jefferson Lab) MAPS. Talks on Feb. 6 th, (Contact JR) (Contact TS)

GEM at CERN. Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM

Recent Advances in Bubble-Assisted Liquid Hole-Multipliers in Liquid Xenon

GEM-based gaseous photomultipliers for UV and visible photon imaging

Micro Pixel Chamber with resistive electrodes for spark reduction

LAAPD Performance Measurements in Liquid Xenon

Proportional Counters

PANDA-X A New Detector for Dark Matter Search. Karl Giboni Shanghai Jiao Tong University

arxiv:physics/ v1 [physics.ins-det] 3 Jul 2006

X-ray ionization yields and energy spectra in liquid argon

Micro Pixel Chamber Operation with Gas Electron Multiplier

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

Momentum Measurement in B Field. Part II. Relative Momentum Error. Contribution from Multiple Scattering

DARWIN: dark matter WIMP search with noble liquids

Signals in Particle Detectors (1/2?)

Chapter 3 Gas Filled Detectors

Spatial resolution measurement of Triple-GEM detector and diffraction imaging test at synchrotron radiation

08 - Miscellaneous and historical detectors

7. Particle identification

Performance of a triple-gem detector for high-rate particle triggering

arxiv:physics/ v1 [physics.ins-det] 14 Feb 2005

NEW DEVELOPMENTS IN GASEOUS DETECTORS. Fabio Sauli. CERN, Geneva, Switzerland

Hybrid Gaseous Detector Module for CEPC-TPC

05 - Scintillation detectors

Resolution. σ z. = σ z. If D(z) is gaussian the relation between FWHM and standard deviation is. = Δz 2.36

Detectors in Nuclear and High Energy Physics. RHIG summer student meeting June 2014

& SUN ZhiJia 1;2. Abstract

Part II. Momentum Measurement in B Field. Contribution from Multiple Scattering. Relative Momentum Error

Low Energy Particles in Noble Liquids

A New GEM-like Imaging Detector with Electrodes Coated with Resistive Layers

DarkSide. Bianca Bottino Università di Genova and INFN Sezione di Genova on behalf of the DarkSide collaboration 1

The current progress of the ALICE Ring Imaging Cherenkov Detector

7 Particle Identification. Detectors for Particle Physics Manfred Krammer Institute of High Energy Physics, Vienna, Austria

LAB 4: Gamma-ray coincidence spectrometry (2018)

Experimental Particle Physics

Count. Count. 200mm. PMT scintillation. PMT flourescence. PMT fluorescence. PMT fluorescence. PMT fluorescence. 50mm. 42mm

Comments on CF 4 -based operations, and GEM-based photodetectors.

Light Dark Matter and XENON100. For the XENON100 Collaboration Rafael F. Lang Columbia University

Radioactivity. Lecture 6 Detectors and Instrumentation

Laboratori Nazionali del GranSasso Alfredo G. Cocco Istituto Nazionale di Fisica Nucleare Sezione di Napoli

Recent Advances in Bubble-Assisted Liquid Hole-Multipliers in Liquid Xenon

3. Gas Detectors General introduction

Scintillation Detector

Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode

the DarkSide project Andrea Pocar University of Massachusetts, Amherst

ATLAS New Small Wheel Phase I Upgrade: Detector and Electronics Performance Analysis

Quality Assurance. Purity control. Polycrystalline Ingots

Waste Characterization

Detecting low energy recoils with Micromegas

EXPERIMENTS CHARACTERIZING THE X-RAY EMISSION FROM A SOLID-STATE CATHODE USING A HIGH-CURRENT GLOW DISCHARGE

Transcription:

R&D on Astroparticles Detectors (Activity on CSN5 2000-2003)

Introduction Results obtained with the R&D activity (2000-2003) with some drift chambers prototypes are reported. With different photocathode structures and new focusing electrodes configurations we obtained a good time-space resolution and a first rate background rejection. Luciano PERIALE (IFSI-CNR, INFN-To) 2

R&D Motivations 1 A A WIMP detector with two-phase Xe Astroparticle Physics 12 (2000) 373-377 L. Periale et al. We describe an important new technique to search for WIMPs: a) method of background discrimination using double phase Xe as detector target; b) ratio between primary scintillation and secondary scintillation; c) special PM with magnesium fluoride window and relative high Q.E. (> 30 %) have been used. Luciano PERIALE (IFSI-CNR, INFN-To) 3

R&D Motivations 2 Measurement of scintillation amplification in Xe-detector with CsI luminescence plate Sources and Detection of Dark Matter and Dark Energy in the Universe: 4 th Int. Symp.. Marina del Rey,, CA, USA, D. Cline Ed. Feb. 23-25, 2000, 485-492 L. Periale et al. We describe the work of our team at CERN, which uses a two- phase Xe detector with a CsI internal Photocathode. We point out a powerful method for amplifying photons in the WIMPs detector; With this setup, one photoelectron produces more than 180 luminescent photons; Taking CsI Q.E. into account, the overall amplification factor of at least 10 was achieved using the new technology improvement. Luciano PERIALE (IFSI-CNR, INFN-To) 4

Set up & results a) CERN, INFN To: Two phase Xenon WIMPs Detector with powerful background discrimination b) Secondary vs primary scintillation plot in two-phase with mixed gamma and neutrons sources (the secondary scintillation photons are produced by electro-luminescence process in gaseous Xe) Luciano PERIALE (IFSI-CNR, INFN-To) 5

Novel photosensitive gaseous detectors We have developed and successfully used several innovative designs of detectors with solid photo-cathodes. The main advantage of these detectors is that rather high gains (> 104) can be achieved in a single multiplication step. The aim of this work is to demonstrate that costly photo-multiplier could be replaced by cheap novel photosensitive gaseous detectors: wire counters, GEMs or glass capillary plates coupled with CsI photo-cathodes. The main advantages of these types of detectors are that their sensitivity could be expanded from VUV up to visible light by choosing the photo-cathode material and that they have a very good (<1 ns) time resolution. The main focus of our report is new fields of applications for this detectors and the optimization of their designs for such purposes. Luciano PERIALE (IFSI-CNR, INFN-To) 6

Detection of primary scintillation photons from dense noble gases As suggested earlier, GPMs with CsI photo-cathodes can be used to detect the primary scintillation photons from noble elements in two- phases. We have performed systematic measurements with Ar,, Kr and Xe gases at pressures in the range of 1-50 atm as well as some preliminary measurements with liquid Xe and liquid Ar. With the gaseous detectors we have succeeded in detecting a scintillation photons produced by 22 kev X-rays with an efficiency close to 100%. We also detected the scintillation photons produced by beta s s (5 kev deposit energy) with an efficiency close to 25%. Luciano PERIALE (IFSI-CNR, INFN-To) 7

Photo of optimized GPM photocathode Most of the CsI photo-cathodes used were prepared at CERN. To avoid photochemical reaction of CsI with the Cu the GEM and the optimizes GPM electrodes were covered in advance with Ni/Au layers. Luciano PERIALE (IFSI-CNR, INFN-To) 8

CsI deposition system at CERN A. Braem lab s is the most attractive facility for any kind of CsI deposition; we are really indebt with his team for the open mind solutions and suggestions. Luciano PERIALE (IFSI-CNR, INFN-To) 9

Experimental set up The setup consists of essentially two parts: a scintillation chamber and a gas chamber containing the test detectors. Basically, it contains a scintillation chamber, separated by windows from the GPM and the PM. In some tests no separation window was used between the scintillation chamber and GPM. Inside the scintillation chamber, a radioactive source was installed: Cd or 90 Sr. 241 Am, 109 Cd Luciano PERIALE (IFSI-CNR, INFN-To) 10 or 90 Sr.

Gas system and GPM&PM set-up The scintillator chamber could be pumped and/or filled with noble elements: Ar,, Kr and Xe at a pressure p= 1-50 atm or in liquid phase. The GPMs were used: a single- wire counter (SWC) with CsI cathode, double GEM operating in tandem, capillarity plates operating and an home made GEM/capillarity-type detector. The SWC had the diameter of the cathode cylinder of 3.8 cm and the diameter of the gold- coated tungsten anode wire of 80 micro. Luciano PERIALE (IFSI-CNR, INFN-To) 11

Measurement conditions a) To achieve the highest possible Q.E. its design had a special feature: the disc (22 mm in diameter) covered with a CsI layer was placed at the distance of 8 mm from the anode wire; b) Two size of GEMs were used: 3x3 and 10x10 cm2 (in all measurements they were used in tandem); c) Two types of configurations were tested; either they were combined with CsI photo-cathodes placed a few mm apart from the first GEM, or the upper GEM was covered with a CsI photosensitive layer. d) Capillarity plates had a diameter of 20 mm and the size of holes was 100 micro. As with GEMs,, they operated in tandem and were combined with CsI photo-cathodes. It was made from G10 plate, 2 mm thick with drilled holes, 1 mm diameter each. e) The detector was operated in a single-step configuration only. f) A charge-sensitive preamplifier Ortec 142 PC was connected to the anode wire; when necessary, the signals were additionally amplified by a Research Amplifier Ortec 450. g) The PM used was EMI-9426 with MgF 2 window. Signals from the GPM and the PM were recorded on a LeCroy digital oscilloscope. Luciano PERIALE (IFSI-CNR, INFN-To) 12

Oscillograms of the signals from GMP and the PM a) GMP signals (upper beam); b) PM signals (middle beam); c) pulse height spectrum (lowest beam). Luciano PERIALE (IFSI-CNR, INFN-To) 13

Signals from optimized GPM&PM a) typical signal of background event crossing the plate; b) typical signals from GPM and PM; c) to achieve the highest possible Q.E. Luciano PERIALE (IFSI-CNR, INFN-To) 14

Very encouraging preliminary results were obtained One should note that in the last few years there have been intense developments of various types of GPMs: : based not only on wire types of detectors, but also on GEM, MICROMEGAS, and glass capillary plate (CP). We performed comparative studies of various types of GPMs for this particular application. Optimization of the GPM for the detection of the scintillation photons from the noble elements. In most measurements, the gas chamber was separated from the scintillation chamber by a CaF2 window. A few tests were done without the separating window when the scintillating chamber and the detector operated in the same noble gas. The following standard designs of GPM were used for comparative studies: MWPC, PPAC, GEM and MICROMEGAS. In the case of the MWPC and the PPAC, designs with only reflective CsI photo-cathodes (400 nm thick) were used. In the case of the GEM and MICROMEGAS, both designs with reflective and semi-transparent (20 nm thick) photo- cathodes were tested. Luciano PERIALE (IFSI-CNR, INFN-To) 15

In addition We also tested two innovative designs of GPMs: : a CP and a photo-sensitive RPC. CPs with capillary hole diameters ranging from 12 to 700 micro were studied. In these studies only capillaries with reflective photo-cathodes were tested: with the cathodes coated by CsI layer and with both cathodes and inner walls of capillaries coated by CsI. The design of the RPC was the following: the 5 cm diameter anode disc was made of Pestov glass with a resistivity of 10 10 ohm.cm ; the cathode was a metallized (~10 nm of Cr) CaF 2 disc (the entrance window) coated with a semi-transparent 20 nm tick CsI layer; the gap between the electrodes was 0.5 mm. All detectors were tested in a mixture of Ar or He with various quenchers (CO2, CH4, C2H6, C4H10) at p=1 atm.. In some cases ethyl-ferrocene vapors were added to these mixture to better suppress ion and photon feedbacks. Luciano PERIALE (IFSI-CNR, INFN-To) 16

in addition There was also a possibility of introducing a 55Fe radiation source inside the drift gap (in the case of PPAC and RPC - directly inside the detector volume) of any of the above described detectors. From the ratio of the amplitude of the signal produced by the 55Fe and the signal due to the scintillation photons, one could estimate the number of detected photoelectrons. To estimate the Q.E. measurements in an ionization chamber mode were done with a Hg lamp used as a light source. In the case of the measurements without the separating window, tests were done with GEMs and CPs (100 micro holes diameter) with only their cathodes coated by a CsI layer. Luciano PERIALE (IFSI-CNR, INFN-To) 17

Results: detectors with window Our main results obtained with various detectors in He-based mixtures can be summarized as follow: the gas mixture for each detector was optimized to find the best compromise between the maximum achievable gain without feedback and sufficient Q.E. Note that only data for CPs with 100 micro hole diameters are included (this geometry offers the maximum gas gain). In our experiments, the Q.E. of the CsI photo-cathodes varied from detector to detector. The measurements in the ionization chamber mode, however (measurement for each particular detector of the photocurrent produced by the Hg lamp), allowed necessary corrections to be made (see the correction factor n, which includes current, geometrical and CsI coating area corrections) and thus all detectors could be compared in such a way as if they had the same Q.E. Luciano PERIALE (IFSI-CNR, INFN-To) 18

Efficiency (to Xe scintillation photons of various window-type GPMs GPM type Optimized gas safe gain QEs (%), n Qer (%), n MWPC He+20% CH4+EF 3. 104 4.3 (1.0) 11.2 (1.25) PPAC He+1% CH4+EF 105 6.7 (2.1) 17.3 (1.0) RPC He+1% CH4+EF 105-5.105 3.2 (2.2) MICROMEGAS He+5% CH4 104 5.3 (2.4) GEM He+10% CO2+EF 103 1.9 (2.6) 3.1 (1.6) CP (CAT mode) He+3%C4H10+EF 3. 103 1.8 (2.7) 2.6 (2.0) Luciano PERIALE (IFSI-CNR, INFN-To) 19

From the data presented, one can see that among the tested detectors with reflective photo-cathodes, the highest gains and Q.Er Er.. Was achieved with the PPAC. Wire-type detectors offer less gains and Q.E.; however, in some experimental environments they can still be very attractive since they do not have any sparking problems. Among detectors with semi-transparent photo-cathodes, the highest gains and Q.Es. was obtained for the RPC. One should point out the very attractive feature of this innovative photo-sensitive detector: RPCs with CsI photo-cathodes can operate at gains of up to 106 without any sparking problems. We point-out, the RPCs also have excellent time resolutions of much better than 1 ns. Of course these conclusions are correct only for single step detectors and for the gas mixtures we tested. For detector operating in a cascade mode or for other gas mixtures, additional studies should be done. Luciano PERIALE (IFSI-CNR, INFN-To) 20

Results: windowless detectors The operation of the CPs and GEM with reflective (400 nm thick) and semi-transparent (20 nm thick) CsI photo-cathodes was studied in pure Ar,, Kr and Xe at p=1-2 atm. The main conclusion from these studies was that both detectors could operate in noble gases only at relatively low gains < 50. To reach gains of > 103 necessary for the single electron detection, two or more CPs or GEMs operating in tandem mode are required, and this may causes additional experimental complications. Luciano PERIALE (IFSI-CNR, INFN-To) 21

Near future The following step to obtain a scale of one or two order expansion of the detector (WARP as an example) is to improve the detection efficiency of neutral particles (single pulses delayed). Luciano PERIALE (IFSI-CNR, INFN-To) 22

Photo cathodes evolution A new scintillation chamber prototype conception using a CsI chess-photocathode configuration is under developing; such a configuration requires a very high selected trigger. Luciano PERIALE (IFSI-CNR, INFN-To) 23

Conclusions The scintillator chamber prototype should be contained in a focusing shield to stress the events detection. Luciano PERIALE (IFSI-CNR, INFN-To) 24

References L. Periale, et al. NIM A 478 (2002) 377, L. Periale, et al. NIM A 497 (2003) 242, L. Periale, et al. NIM A 502 (2003) 189, Luciano PERIALE (IFSI-CNR, INFN-To) 25