Performance of a triple-gem detector for high-rate particle triggering

Similar documents
A Complete Simulation of a Triple-GEM Detector

A fast triple GEM detector for high-rate charged-particle triggering

A complete simulation of a triple-gem detector

A Triple-GEM Telescope for the TOTEM Experiment

The Cylindrical GEM detector for the KLOE-2 Inner Tracker

GEM at CERN. Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

GEM: A new concept for electron amplification in gas detectors

Neutron Structure Functions and a Radial Time Projection Chamber

GEM upgrade of the ALICE TPC. Markus Ball Physics Department E18 Technische Universität München On Behalf of the ALICE TPC upgrade

Flux and neutron spectrum measurements in fast neutron irradiation experiments

Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode

Electron transparency, ion transparency and ion feedback of a 3M GEM

Particle Energy Loss in Matter

Physics studies to define the CMS muon detector upgrade for High-Luminosity LHC

THE MULTIGAP RESISTIVE PLATE CHAMBER. Abstract

Characterization and installation at FTU (ENEA) of a fast neutron flux monitor;

arxiv:physics/ v2 27 Mar 2001

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Optimization of the Gas Flow in a GEM Tracker with COMSOL and TENDIGEM Development. Presented at the 2011 COMSOL Conference

Nuclear Instruments and Methods in Physics Research A

BEAM BEAM. cathode anode cathode

GEM-based photon detector for RICH applications

Advances in the Micro-Hole & Strip Plate gaseous detector

Status and Challenges of CEPC Time Projection Chamber Detector. Huirong On behalf of CEPC Tracking Subgroup

Micro-pattern gaseous detectors

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

Microscopic Simulation of GEM Signals

Results with Micromegas modules at LP-TPC

Detectors in Nuclear and High Energy Physics. RHIG summer student meeting June 2014

THE MULTIGAP RESISTIVE PLATE CHAMBER

Lecture 18. New gas detectors Solid state trackers

Tests of the BURLE 64-anode MCP PMT as the detector of Cherenkov photons

Status of the LHCb Experiment. Ueli Strauman, University of Zurich, Switzerland. Sept. 13, 2001

Detectors for Particle Physics. Lecture 2: Drift detectors Muon detectors MWPC, CSC, RPC, TRT, TPC, Cherenkov

A proposal to study gas gain fluctuations in Micromegas detectors

Micro Pixel Chamber Operation with Gas Electron Multiplier

A new detector for neutron beam monitoring

Ionization Detectors

Precision Calibration of Large Area Micromegas Detectors Using Cosmic Muons

PHOTOELECTRON COLLECTION EFFICIENCY AT HIGH PRESSURE FOR A GAMMA DETECTOR ENVISAGING MEDICAL IMAGING

Rate Dependency Study on Gas Electron Multiplier Gain

Simulation of GEM-TPC Prototype for the Super-FRS Beam Diagnostics System at FAIR

Digital Hadron Calorimetry for the Linear Collider using GEM Technology

Development of a new MeV gamma-ray camera

Gas Properties and Dierent Detector Geometries for Multi-GEM Detectors in the CMS Detector

Development of a Time Projection Chamber with GEM technology in IMP. Herun yang Gas detector group

HIGH energy physics research requires a constant improvement

ATLAS New Small Wheel Phase I Upgrade: Detector and Electronics Performance Analysis

Angular resolution of the gaseous micro-pixel detector Gossip

Resolution. σ z. = σ z. If D(z) is gaussian the relation between FWHM and standard deviation is. = Δz 2.36

CCD readout of GEM-based neutron detectors

Spatial resolution measurement of Triple-GEM detector and diffraction imaging test at synchrotron radiation

Investigation of GEM space point resolution for a TPC tracker

Charge readout and double phase

arxiv: v1 [physics.ins-det] 28 Mar 2016

Progress in the Development of Photosensitive GEMs with Resistive Electrodes Manufactured by a Screen Printing Technology

arxiv: v1 [physics.ins-det] 7 Dec 2018

Measurement of the front-end dead-time of the LHCb muon detector and evaluation of its contribution to the muon detection inefficiency

Hybrid Gaseous Detector Module for CEPC-TPC

R&D on Astroparticles Detectors. (Activity on CSN )

Performance test of triple GEM detector at CERN n_tof facility

Experimental Particle Physics

Experimental Methods of Particle Physics

A gas-filled calorimeter for high intensity beam environments

Particle Detectors. Summer Student Lectures 2007 Werner Riegler, CERN, History of Instrumentation History of Particle Physics

arxiv: v1 [physics.ins-det] 3 Jun 2016

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Part II. Momentum Measurement in B Field. Contribution from Multiple Scattering. Relative Momentum Error

Response uniformity of a large size RPC

Micro Pixel Chamber with resistive electrodes for spark reduction

Experimental Particle Physics

Detector Physics of Resistive Plate Chambers

Experimental Particle Physics

Design, construction and test of Boron Array Neutron Detector - Gas Electron Multiplier (BAND-GEM)

EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH GAS DETECTORS: ACHIEVEMENTS AND TRENDS. Fabio Sauli. CERN, CH-1211 Geneva, Switzerland ABSTRACT

polarized HCAL ECAL2 ECAL1 HCAL1

3. Gas Detectors General introduction

3 Gaseous Detectors. Detectors for Particle Physics Manfred Krammer Institute for High Energy Physics, Vienna, Austria

Particle Energy Loss in Matter

ALICE-TPC upgrade with GEMs. Jens Wiechula for the ALICE TPC Upgrade collaboration

Detector Design Studies For High Precision Particle Physics Experiment

Equalisation of the PMT response to charge particles for the Lucid detector of the ATLAS experiment

Tracking properties of the ATLAS Transition Radiation Tracker (TRT)

Spatial resolution of a MPGD TPC using the charge dispersion signal

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

7. Particle identification

Study of GEM-like detectors with resistive electrodes for RICH applications

NEW DEVELOPMENTS IN GASEOUS DETECTORS. Fabio Sauli. CERN, Geneva, Switzerland

Track Resolution Measurements for a Time Projection Chamber with Gas Electron Multiplier Readout

Development of High-Z Semiconductor Detectors and Their Applications to X-ray/gamma-ray Astronomy

PoS(RPC2012)034. Simulation studies on the Effect of SF 6 in the RPC gas mixture

ISPA-Tubes with YAP:Ce Active Windows for X and Gamma Ray Imaging.

Breakdown limit studies in high-rate gaseous detectors

PERFORMANCE OF THE ATLAS LIQUID ARGON FORWARD CALORIMETER IN BEAM TESTS

arxiv: v2 [nucl-ex] 6 Oct 2008

Evaluation and reduction of ion back-flow in multi-gem detectors

RATE CAPABILITY OF A HIGH EFFICIENCY TRANSITION RADIATION DETECTOR

arxiv:physics/ v2 [physics.ins-det] 31 Oct 2003

arxiv:physics/ v1 [physics.ins-det] 2 Aug 2000

Transcription:

Performance of a triple-gem detector for high-rate particle triggering G. Bencivenni 1, W. Bonivento 2,4,A.Cardini 2,C. Deplano 2, P. de Simone 1, G. Felici 1, D. Marras 2, F.Murtas 1, D.Pinci 2,3, M. Poli-Lener 1 and D. Raspino 2 1 - Laboratori Nazionali di Frascati - INFN, Frascati, Italy 2 - Sezione INFN di Cagliari Cagliari, Italy 3 - Università degli Studi di Cagliari, Cagliari, Italy 4 - Now at CERN, Geneva, Switzerland M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 1

OUTLINE Principle of Operation Triple-GEM Prototypes Construction and LHCb Requirements Optimizing Time Performances Detector Performances with CF 4 and iso-c 4 H 10 gas mixtures Aging & Rate capability Preliminary results on Discharges Conclusions M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 2

Principle of Operation A Gas Electron Multiplier (GEM) is a thin (50 µm) kapton foil, copper clad on each side with a high density of holes acting as electron multiplication channels. Equipotential lines Field lines Holes are bi-conical with external diameter of 70µm, internal of 50 µm and pitch of 140 µm. Voltages of 400-500 V are applied between the two copper sides, giving fields as high as ~100 kv/cm into the holes, resulting in a gain of the order of 10 3 for mono-gem detector. Larger gain, in safe condition, up to 10 4-10 5, are usually achieved using two or more GEM foils in cascade. Maxwell 3D Simulation Signals are read out at the anode with pad/strip electrodes. M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 3

Prototype Construction: GEM foil preparation Glued G10 frame (2) (1) GEM foil A special tool is used to stretch the 100x100 mm 2 GEM foils (1) A 1mm-thick frame is then glued to the GEM with a fast polymerizing epoxy resin (2) After gluing, the GEM is removed from the stretching tool and the kapton foil exceeding the frame is removed (3) (3) M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 4

Prototype construction: detector geometry Drift cathode GEM 1 GEM 2 GEM 3 Readout PCB Drift Transfer 1 Transfer 2 Induction 3 mm 1 mm 2 mm 1 mm pre-amplifier Gold-plated PCB with 10x25 mm 2 pads (total active area 100x100 mm 2 ) is used to readout the detector. Each pad is connected to a fast pre-amplifier. M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 5

Prototype construction: detector assembling Detectors are assembled in a class 100 laminar flow bench. GEMs are stacked in a gas-tight G10 box above the pads. The cathode plane is positioned above the three GEMs. All electrodes are connected to small plugs used to supply HV to the GEMs M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 6

Prototype construction: f.e.e. & HV Amplifier Kloe/VTX ASDQ (*) (*) Not tested yet Discriminator external on-chip Input Impedance (Ω) 110 250 Peaking Time (ns) 6 8 Noise (e - r.m.s.) 1350 2200 Sensitivity (mv/fc) 10 25 Baseline Restoration yes yes Channel/Chip 6 8 Each GEM electrode is connected, through an R-C-R filter (for a total resistance of 2MΩ in series) to an individual HV channel M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 7

Detector Requirements A triple-gem detector is being proposed for the Central Region of the first Muon Station of the LHCb experiment at CERN, for which the requirements are: Rate Capability ~ up to about 0.5 MHz/cm 2 Station Efficiency ~ 99% in a 25 ns time window (*) Cluster Size ~ 1.2 for a 10x25 mm 2 pad size Radiation Hardness ~ 6 C/cm 2 in 10 years (for G ~ 10 4 ) (*) A station is made of two detectors in OR, pad by pad. This improves time resolution and provides some redundancy. M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 8

Time Performances The time at which the charged particle crosses the GEM-based detector is measured with a single threshold leading edge voltage discriminator following a charge preamplifier/shaper. Since the probability distribution of the distance x of the cluster closest to the first GEM is P(x) = ne -nx and σ(x) = 1/n, the intrinsic time spread of a GEM detector is: σ(t) = 1/nv drift, where n is the number of clusters per unit length and v drift is the electron drift velocity in the ionization gap. To achieve a fast detector response, high yield and fast gas mixtures are then necessary. In addition, high efficiency for single cluster detection is required. That is high GEM transparency to electrons (especially for the first GEM foil) is needed. M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 9

Time Performances: transparency The collection efficiency of primary electrons through the holes decreases with the increasing of the electric field above the GEM because of the defocusing of the field lines (some electrons could hit the GEM upper electrode); The electron multiplication into the holes, increases exponentially with the GEM voltage; The extraction efficiency of secondary electrons from the holes increases with the increasing of the electric field below the GEM. By C.Richter (8 th Elba Conference) M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 10

Time Performances: Drift velocity & Ionization Ar/CO 2 (70/30): 7 cm/µs from @ 3 kv/cm 10 clusters in 3 mm Ar/CO 2 /CF 4 (60/20/20): 9 cm/µs from @ 3 kv/cm 15 clusters in 3 mm Ar/CO 2 /CF 4 /iso-c 4 H 10 (65/8/20/7): 9 cm/µs from @ 2.5 kv/cm 16 clusters in 3 mm Ar/CF 4 /iso-c 4 H 10 (65/28/7): 11.5 cm/µs from @ 2 kv/cm 17 clusters in 3 mm High drift velocity at low fields allows fast detector response while keeping high efficiency in electron collection at the first GEM (defocusing effect) M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 11

PSI - Test Beam The PSI πm1 beam is a (quasi) continuous high-intensity secondary beam (10 7 π - /s or 10 8 π + /s a 350 MeV/c for each ma of beam current in the primary beam). Pions arrive in 1 ns-wide bunches every 20 ns. Spot size on target (FWHM): 15 mm horizontal, 10 mm vertical Pions at 350 MeV/c are at the minimum of ionization. Data were taken with two different beam setting: LOW (~30 khz on the detector active area) HIGH intensity pions (~50 MHz on active area) LOW intensity: efficiency, time resolution measurement HIGH intensity: discharge probability measurement M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 12

Time Resolution: single detector Ar/CO 2 =70/30 T(ns) Ar/CO 2 /CF 4 =60/20/20 T(ns) Time resolution rms (ns) Ar/CO 2 /CF 4 / Iso=65/8/20/7 T(ns) Ar/CF 4 / Iso=65/28/7 T(ns) M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 13

Time Resolution: two detectors in OR Ar/CO 2 /CF 4 =60/20/20 T(ns) Ar/CO 2 /CF 4 / Iso=65/8/20/7 Time resolution rms (ns) T(ns) Ar/CF 4 / Iso=65/28/7 T(ns) M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 14

Efficiency in 25 ns time window Single chamber Two chambers in OR Efficiency in 25 ns Efficiency in 25 ns 99% Ar/CF 4 /C 4 H 10 = 65/28/7 ε max = 98.7 % Ar/CO 2 /CF 4 /C 4 H 10 = 65/8/20/7 ε max = 97.8 % Ar/CO 2 /CF 4 = 60/20/20 ε max = 97.2 % Working region To be compared with ε max = 89.0 % measured with Ar/CO 2 M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 15

GAIN MEASUREMENT The effective GAIN G eff of the detector has been estimated using a 5.9 kev X-ray tube, measuring the rate R and the current i, induced on pads, by X-rays incident on the GEM detector. G eff = i / enr G eff eαx(vg1+ VG2+ VG3) M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 16

RATE CAPABILITY The rate capability of the GEM detector (at a Gain of ~ 10 4 ) has been measured by means the X-ray tube up to ~ 60 MHz/cm 2 Normalized Gain vs X-ray rate The detector Gain remains stable up to very high X-ray fluxes LHCb upper limit for R1,R2 of M1 M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 17

AGING TEST The aging test has been performed by irradiating with a high intensity (50 MHz/cm 2 ) 5.9 kev X-rays the detector operated with the Ar/CO 2 /CF 4 = 60/20/20 gas mixture @ G ~ 2x10 4 (ΣV GEM = 1230 V) A total charge of ~23 C/cm 2 has been integrated. Taking into account 1 year (10 7 sec) at LHCb, the triple-gem detector placed in R1,R2 of M1 will integrate a charge of Q LHCb ~ 1.3 C/cm 2 We can conclude that the detector survives ~18 years with negligible changes (~5%) in its operation. Variations of P,T have been corrected with a second, low irradiated, GEM chamber used as monitor. Gas was supplied with open flow system, using Polypropylene tubes. The gas flow was 100cc/min, well above the limit for gas poisoning AGING for isobutane gas mixtures will be done in the near future M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 18

DISCHARGE STUDIES (I) The occurrence of discharges in gas detectors is correlated with the transition from avalanche to streamer. The transition is voltage and ionization density dependent: in fact streamers more easily occur when a large number of electron-ion pairs is released by particles in the gas volume (highly ionizing particles). In this case the total charge created by the multiplication processes could exceed the threshold value (Raether limit, 10 7-10 8 e-i + pairs) for the transition from avalanche to streamer. Due to the very small anode-cathode distance in GEM detectors (more generally in micro-pattern detectors) the transition from avalanche to streamer is most of the time followed by discharges. For triple-gem detectors this means that the discharge probability is larger in the third GEM where the charge density is higher. M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 19

DISCHARGE STUDIES (II) The dependence of the discharge probability on GEM voltages and gas mixtures has been studied by irradiating the detector with 5.6 MeV α-particles from an 241 Am source. The statistical significance of the zero baseline corresponds to 1 discharge during a time of 12 hours, or a probability of less than ~2x10-7. Discharge probability is more sensitive to V G3 than the other GEM voltages. The use of a good quencher, like isobutane, allows to reduce the discharge probability and to reach higher gains. V G1 > V G2 > V G3 M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 20

DISCHARGE STUDIES (III) GEM detectors have been tested at PSI with a hadron beam of 50 MHz on the active area. Discharges have been counted by monitoring current spikes At the working points the discharge probability, at 95% C.L., is lower than 4x10-12 2x10-11 / hadron, corresponding to 200 1000 discharge/cm 2 in 10 years at LHCb (R1,R2 of M1) During test beam exposures and α-particle tests the detector integrated, WITHOUT DAMAGES, about 220 discharges/cm 2, corresponding to 3 10 LHCb years NO discharges in 6 hour runs M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 21

Last minute Large size triple-gem 24 cm 6sectors 20 cm HV contacts GEM: : proto construction Since the stretching tool allows a very efficient foil tensioning, also for large size GEM, NO GRID SPACER is required to sustain the GEM 1 MΩ limiting resistors GEMs are stacked in a gas-tight G10 box above the pads. The cathode plane is positioned above the three GEMs. All electrodes are connected to small plugs used to supply HV to the GEMs HV contacts for the first frame HV Distribution card M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 22

Last minute Large size triple-gem: β-source test HV connection Source test Current (na) A B C D E in current mode B C A E D Time M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 23

CONCLUSIONS CF 4 and isobutane based gas mixtures allow to have a fast, stable and robust GEM detector, all the LHCb requirements are fulfilled: Time performances (large improvements with respect to the Ar/CO 2 gas mixture): good, 5.3 ns r.m.s., for Ar/CO 2 /CF 4 (60/20/20); excellent, 4.5 ns r.m.s., for Ar/CF 4 /iso-c 4 H 10 (65/28/7); good efficiency in 25 ns for isobutane/cf4 based gas mixtures. Aging: small effects observed after accumulating 23 C/cm 2 with Ar/CO 2 /CF 4 (60/20/20) at an effective gain of 2x10 4 corresponding to ~18 years at LHCb; Rate Capability: fine!! Discharge probability: lower than 4x10-12 2x10-11 / hadron with pions from the PSI πm1 beam; with α-particles we studied the dependence on various parameters: voltages, electric fields and gas mixtures. with α-particle the detector could withstand about 220 discharges/cm 2 without damages, corresponding to 3 10 LHCb years. The first chamber of 20x24 cm 2 has been recently built and works well!! M.Poli Lener LNF/INFN 8-th International Conference On Instrumentation for Colliding Beam Physics 24