Analysis By Time-Of-Flight Secondary Ion Mass Spectroscopy or Nuclear Products In Hydrogen Penetration Through Palladium

Similar documents
Fig.1 Pyrex glass cell

TRITIUM PRODUCTION IN PALLADIUM DEUTERIDE/HYDRIDE IN EVACUATED CHAMBER

NUCLEAR TRANSMUTATION IN DEUTERED PD FILMS IRRADIATED BY AN UV LASER

Thin Pd Film : 400A CaO and Pd Layers :1000A Bulk Pd : 0.1mm

Replication Of MHI Transmutation Experiment By D 2 Gas Permeation Through Pd Complex

DETECTION OF ANOMALOUS ELEMENTS, X-RAY AND EXCESS HEAT INDUCED BY CONTINUOUS DIFFUSION OF DEUTERIUM THROUGH MULTI-LAYER CATHODE (Pd/CaO/Pd)

Analysis of Nuclear Transmutation Induced from Metal Plus Multibody-Fusion-Products Reaction

Search for Nuclear Reaction Products in Gas Phase Experiments - Deuterium Permeation and Absorption -

Observation of Nuclear Transmutation Reactions induced by D 2

A.DE NINNO, A. FRATTOLILLO, A. RIZZO. ENEA C.R. Frascati,Via E. Fermi 45, Frascati (Rome), Italy E. DEL GIUDICE

Transmutation Reaction Induced by Deuterium Permeation Through Nanostructured Multi-layer Thin Film

Yasuhiro Iwamura, Takehiko Itoh, Nobuaki Gotoh and Ichiro Toyoda

Palladium fission triggered by polyneutrons

Studies on 3D Fusion Reactions in TiDx under Ion Beam Implantation

OBSERVATION OF SURFACE DISTRIBUTION OF PRODUCTS BY X-RAY FLUORESCENCE SPECTROMETRY DURING D 2 GAS PERMEATION THROUGH PD COMPLEXES

OBSERVATION OF NUCLEAR TRANSMUTATION REACTIONS INDUCED BY D 2 GAS PERMEATION THROUGH PD COMPLEXES

NEUTRINO DINEUTRON REACTIONS (LOW-ENERGY NUCLEAR REACTIONS INDUCED BY D 2 GAS PERMEATION THROUGH PD COMPLEXES. Y. IWAMURA EFFECT)

Progress on Transmutation Experiments induced by D 2 gas permeation

ELEMENTAL ANALYSIS OF PALLADIUM ELECTRODES AFTER PD/PD LIGHT WATER CRITICAL ELECTROLYSIS

Anomalous Heat Generation in Charging of Pd Powders with High Density Hydrogen Isotopes (I) Results of absorption experiments using Pd powders

CATHODE MATERIAL CHANGE AFTER DEUTERIUM GLOW DISCHARGE EXPERIMENTS

THE PRECURSOR OF "COLD FUSION" PHENOMENON IN DEUTERIUM/ SOLID SYSTEMS

SEARCH FOR COHERENT DEUTERON FUSION BY BEAM AND ELECTROLYSIS EXPERIMENTS

SURFACE STUDIES AFTER LOADING METALS WITH HYDROGEN AND/OR. DEUTERIUM J. Dash and D.S. Silver. Portland, Oregon

ANALYSIS OF NUCLEAR TRANSMUTATION INDUCED FROM METAL PLUS MULTIBODY-FUSION- PRODUCTS REACTION

THE PRECURSOR OF "COLD FUSION" PHENOMENON IN DEUTERIUM/ SOLID SYSTEMS

Synthesis Of A Copper Like Compound From Nickel And Hydrogen And Of A Chromium Like Compound From Calcium And Deuterium

NUCLEAR PRODUCTS IN A GAS-LOADIND D/PD AND H/PD SYSTEM

Enhanced Tc Superconductivity and Anomalous Nuclear Emissions in YBCO and Palladium

LABORATORI NAZIONALI DI FRASCATI SIS Pubblicazioni

X-RAY EMISSION DURING ELECTROLYSIS OF LIGHT WATER ON PALLADIUM AND NICKEL THIN FILMS

Deuterium Permeation Induced Transmutation Experiments using Nano-Structured Pd/CaO/Pd Multilayer Thin Film

A Review of Transmutation and Clustering in Low Energy Nuclear Reactions

Steady-state diffusion is diffusion in which the concentration of the diffusing atoms at

Anomalous production of gaseous 4 He at the inside of DScathode during D 2 O-electrolysis

AUTORADIOGRAPHY OF DEUTERATED Ti AND Pd TARGETS FOR SPATIALLY RESOLVED DETECTION OF TRITIUM PRODUCED BY COLD FUSION

Exothermic reaction induced by high density current in metals Possible nuclear origin JACQUES DUFOUR, DENIS MURAT, XAVIER DUFOUR, JACQUES FOS

How to Cause Nuclear Reactions at Low Energy and Why Should You Care

Pd Complex. Pd complex containing CaO. Thin Pd Film : 400A. CaO and Pd Layers :1000A. Bulk Pd : 0.1mm

Is Gamma-Less Transmutation Possible? -The Case of Metal plus TSC and BOLEP-

Are Nuclear Transmutations Observed At Low Energies Consequences Of Qed Coherence?

Deuterium Gas Charging Experiments with Pd Powders for Excess Heat Evolution (II) Discussions on Experimental Results and Underlying Physics

EXCESS HEAT AND HEAT AFTER DEATH IN A GAS- LOADING HYDROGEN/PALLADIUM SYSTEM

What is now known about cold fusion? (Addendum to the Student s Guide) Edmund Storms March 23, 2011

Overview of X-Ray Fluorescence Analysis

EXCESS HEAT PRODUCTION IN Pd/D DURING PERIODIC PULSE DISCHARGE CURRENT IN VARIOUS CONDITIONS

DESIGN AND INITIAL TESTING OF THE LANP COMPUTER MODEL OF THE COLD FUSION PROCESS

Search For Nuclear Ashes In Electrochemical Experiments

CF-MATTER AND THE COLD FUSION PHENOMENON *

Basic research on condensed matter nuclear reaction using Pd powders charged with high density deuterium

MS482 Materials Characterization ( 재료분석 ) Lecture Note 12: Summary. Byungha Shin Dept. of MSE, KAIST

Implantation Energy Dependence on Deuterium Retention Behaviors for the Carbon Implanted Tungsten

Clusters with Picometer Distance of Deuterons and LENR

Nuclear Transmutation Reaction Occurring during. The Light Water Electrolysis on Pd Electrode.

PROGRESS IN GAS-LOADING D/Pd SYSTEM. The feasibility of a self-sustaining heat generator

Deuterium (Hydrogen) Flux Permeating through Palladium and Condensed Matter Nuclear Science

The 11th Meeting of Japan CF-Research Society JCF11 ABSTRACTS. December 11-12, Morioka, Iwate. Japan CF-Research Society

DETECTION OF ANOMALOUS ELEMENTS, X-RAY, AND EXCESS HEAT IN A D 2 -Pd SYSTEM AND ITS INTERPRETATION BY THE ELECTRON-INDUCED NUCLEAR REACTION MODEL

CALCULATIONS OF NUCLEAR REACTIONS PROBABILITY IN A CRYSTAL LATTICE OF LANTHANUM DEUTERIDE

Teflon lid. O ring. Catalyst. Catalyst Chamber. Electrolyte (H 2 SO 4 + de-ionized H 2 0)

Reproduction of Fleischmann and Pons experiments

Absorption Capacity and Heat Evolution with Loading of Hydrogen Isotope Gases for Pd Nanopowder and Pd/Ceramics Nanocomposite

Elastic Recoil Detection Method using DT Neutrons for Hydrogen Isotope Analysis in Fusion Materials. Abstract

Clusters with Picometer Distance of Deuterons and LENR

HOME NEWS CONFERENCES CONVERSATIONS LINKS SUPPORT ABOUT. Cold Fusion for Dummies. (Last update: Jan. 6, 2006)

Mechanism Of Deuteron Cluster Fusion By EQPET Model

Is the Abundance of Elements in Earth s Crust Correlated with LENR Transmutation Rates?

PROGRESS TOWARDS REPLICATION

NUCLEAR EMISSIONS FROM TITANIUM HYDRIDE/DEUTERIDE INDUCED BY POWERFUL PICOSECOND LASER BEAM

SEY and Surface Analysis Measurements on FNAL Main Injector Ring S/S Beam Chamber Material

EXCESS HEAT AND UNEXPECTED ELEMENTS FROM AQUEOUS ELECTROLYSIS WITH TITANIUM AND PALLADIUM CATHODES

These PowerPoint slides accompany a lecture on the topics described in the paper:

EMISSION REGISTRATION ON FILMS DURING GLOW DISCHARGE EXPERIMENTS

Anomalous Effects in Charging of Pd Powders with High Density Hydrogen Isotopes Fukaeminami-machi, Higashinada-ku, Kobe , Japan

Figure 1: Two pressure shocks causing the sample temperature increase (Termocouple Tc1, figure 1b of reference [2]). 2 Heat production Apart from the

Experimental Evidence for LENR in a Polarized Pd/D Lattice

SUPER-ABSORPTION CORRELATION BETWEEN DEUTERIUM FLUX AND EXCESS HEAT

Fig 1: Auger Electron Generation (a) Step 1 and (b) Step 2

POLYNEUTRON THEORY OF TRANSMUTATION

Secondary ion mass spectrometry (SIMS)

Nuclear Transmutations (NTs) in Cold Fusion Phenomenon (CFP) and Nuclear Physics

ISOTOPIC CHANGES OF THE REACTION PRODUCTS INDUCED BY CATHODIC ELECTROLYSIS IN Pd

Observations Regarding Automated SEM and SIMS Analysis of Minerals. Kristofor Ingeneri. April 22, 2009

Measurement Artifacts in Gas-loading Experiments

Alex M Imai, Y. Ohta and A. Itoh Department of Nuclear Engineering, Kyoto University

A cryogenic detector for 222 Rn

Secondary Ion Mass Spectrometry (SIMS) Thomas Sky

In-situ Ar Plasma Cleaning of Samples Prior to Surface Analysis

Studies on bi-directional hydrogen isotopes permeation through the first wall of a magnetic fusion power reactor

Charged particles from Ti and Pd foils

STUDY ON CORROSION P HENOMENA OF STEELS IN PB-BI FLOW

Portable type TXRF analyzer: Ourstex 200TX

Subject Index. See for options on how to legitimately share published articles.

ANOMALOUS HEAT FLOW AND ITS CORRELATION WITH DEUTERIUM FLUX IN A GAS-LOADING DEUTERIUM-PALLADIUM SYSTEM

THE ROLE OF ALKALINE IONS IN DYNAMIC MOVEMENT OF HYDROGEN ISOTOPES IN Pd

CHARGED PARTICLE EMISSIONS AND SURFACE MORPHOLOGY OF THE Pd/PdO:Dx AND THE TiDx TARGETS UNDER AN ELECTRON BEAM EXCITATION

Experimental Evidence for LENR in a Polarized Pd/D Lattice

EXPERIMENTS CHARACTERIZING THE X-RAY EMISSION FROM A SOLID-STATE CATHODE USING A HIGH-CURRENT GLOW DISCHARGE

DEPOSITION OF THIN TiO 2 FILMS BY DC MAGNETRON SPUTTERING METHOD

Neutron emission from D 2 gas in magnetic fields under low temperature. Summary. 1:Introduction

Transcription:

Yamada, H., et al. Analysis By Time-Of-Flight Secondary Ion Mass Spectroscopy For Nuclear Products In Hydrogen Penetration Through Palladium. in Tenth International Conference on Cold Fusion. 2003. Cambridge, MA: LENR-CANR.org.This paper was presented at the 10th International Conference on Cold Fusion. It may be different from the version published by World Scientific, Inc (2003) in the official Proceedings of the conference. Analysis By Time-Of-Flight Secondary Ion Mass Spectroscopy or Nuclear Products In Hydrogen Penetration Through Palladium H. YAMADA, S. NARITA, H. ONODERA, H. SUZUKI, N. TANAKA, T. NYUI AND T. USHIROZAWA Department of Electrical and Electronic Engineering, Iwate University, Ueda 4-3-5, Morioka 020-8551 Japan E-mail: yamada@dragon.elc.iwate-u.ac.jp Elemental analysis was performed for the palladium foil through which the hydrogen gas penetrated. We analyzed sample surface by Time-of-Flight secondary ion mass spectroscopy and searched for newly produced elements during the gas permeation process. Significant increase of the counts for Cr, Fe, Cu and Ag were found after the permeation. These elements could have been produced by nuclear transmutation. 1 Introduction The possibility of inducing nuclear reactions at low temperature in solid-state has been widely investigated for these years. Among several experimental methods for the reaction, the controlled gas out-diffusion with palladium (Pd) deuteride or hydride in the evacuated chamber is one of the unique methods [1,2]. It was developed by Yamaguchi et al. and called in vacuo method. They observed the excess heat and helium production, which was thought to be a possible result of a nuclear reaction. The gas penetration method is another unique one. Iwamura et al. has studied using this method with Pd film complexes, which consist of a thin Pd layer, a CaO and a bulk Pd [3,4]. They have reported observation of elements production in deuterium permeation experiment and recently have found a certain rule of nuclear transmutation, that is, 8 mass number and 4 atomic number increase in the process. The phenomenon was observed with good reproducibility. These results suggest that there is a key to understand the reaction in the mobility of D (or H) atoms in Pd lattice. In this present study, we have performed the similar penetration experiment using hydrogen with Pd foil without any additional layer, and have searched for nuclear products as a result of low energy reaction. This method has an advantage of involving less contamination of the palladium sample in contrast to other method; the method is preferably used in investigating small amount of elements. This study would provide us information to understand transmutation process systematically. In addition, we would consider the possibility of nuclear transmutation in not only deuterium but also hydrogen system as some researchers have claimed in various experiments [5,6].

H 2 Gas A n a lyzed region by T O F -S I M S O-ring S a m p le Sample H o lder Fig. 1 Sample holder: Hydrogen flows from upper chamber to lower chamber by penetrating the Pd sample. 2 Experiment The Pd plate (99.95% pure) sample (0.1 12.5 12.5mm) was rinsed with acetone and pure water, then washed by aqua regia to remove impurities on the sample surface. No hydrogen gas was loaded to the sample before experiment. Fig. 1 shows the sample holder and flowing path of the hydrogen gas. The Pd plate was set into a stainless steel holder placed between two chambers. The upper chamber is filled with hydrogen gas at a pressure up to 10 atm, and the lower is evacuated by a diaphragm pump (ULVAC: DAM-010) to prevent the Pd sample from being contaminated from the atmosphere. The gas atoms are driven through the Pd sample to the evacuated chamber by the pressure gradient. The lower sample holder has several holes where the gas flows. The gas was kept flowing for about 2 weeks, then the sample ( After sample ) was taken out from the holder. Before the element analysis, the sample was heated to 400 to purge the hydrogen atoms remaining in. Finally the sample surface of high-pressure side was analyzed by Time-of-Flight secondary mass spectroscopy (TOF-SIMS) (ULVAC-PHI: TFS-2100). TOF-SIMS has a good sensitivity for a small quantity of the elements on the sample with high resolution in mass number although it is difficult to deduce the absolute quantities from its output data alone. The primary ion in TOF-SIMS was Ga + and measured area was 40 40 micron square. In order to take into account the contamination from the environment, we prepared the control sample ( Control sample ), which was set into and removed from the holder without flowing the hydrogen gas, and compared the composition of the elements on the sample between them to specify newly produced elements during the experiments. TOF-SIMS is capable of analyzing all the elements with their isotopes. We also analyzed the isotopic compositions for the elements detected.

3 Results and Discussion 3.1 Possible elements production In TOF-SIMS analysis, three randomly selected areas (40μm 40μm) of each sample were analyzed. We did not see significant difference in the mass spectrum for every area. In this study, we do not discuss absolute quantities of the elements, since we have difficulties in quantitative analysis with the TOF-SIMS method. Instead, we use a normalized intensity that is defined here as the count of the secondary ions of each element divided by the total count of ions recorded, and multiplied by 10000. Fig. 2 shows a typical mass spectrum obtained for the Pd surface of the Control sample in the mass number range of 42-65. Low intensities corresponding to elements of Ca, Cr, Mn, Fe, Ni and Cu are seen. These elements are considered to be the impurities included in the Pd sample and contaminants introduced from environments during the time between the experiment and the TOF-SIMS analysis. Fig. 3 shows a typical spectrum of the sample after the gas penetration. Increasing of the intensity for mass numbers 50, 52, 53, 54, 55, 56, 57, 58, 60, 63, 64 and 65 can be seen. These mass numbers correspond to elements of Cr ( 50 Cr, 52 Cr, 53 Cr, 54 Cr), Mn ( 55 Mn), Fe ( 54 Fe, 56 Fe, 57 Fe), Ni ( 58 Ni, 60 Ni, 64 Ni), Cu ( 63 Cu, 65 Cu) and Zn( 64 Zn), respectively. The TOF-SIMS system is capable of removing the surface layers of the sample by Ga sputtering for surface cleaning and measurement of depth distribution. Fig. 4 and Fig. 5 show mass spectrum after 10s sputter cleaning by Ga + ion beam for the same area as Fig. 2 and Fig. 3, respectively. Fig. 4 gives similar spectrum to Fig. 2 for the case of Control sample. Fig. 2 Normalized count intensity for mass number 42-65 for the control Pd sample.

Fig. 3 Normalized count intensity for mass number 42-65 for the Pd sample after experiment. Fig. 4 Normalized count intensity for the control Pd sample with 10s sputtering.

Fig. 5 Normalized count intensity after experiment with 10s sputtering. Most of the elements with low intensities appearing in Fig. 4 are thought to be impurities included in the Pd foil. After the experiment, increase in the intensity for mass numbers 46, 47, 48, 49, 50, 52, 53, 54, 55, 56 and 63 can be seen in Fig. 5. These correspond to elements of Ti ( 46 Ti, 47 Ti, 48 Ti, 49 Ti, 50 Ti), Cr ( 50 Cr, 52 Cr, 53 Cr, 54 Cr), Mn ( 55 Mn), Fe ( 54 Fe, 56 Fe) and Cu ( 63 Cu), respectively. In particularly, marked increases in the intensities for Cr, Fe and Cu were observed. We also found elements of mass number 51, 57, 58, 59 and 65 only after experiments, which correspond to elements of 51 V, 57 Fe, 58 Fe, 58 Ni, 59 Co, and 65 Cu, respectively. Furthermore, considerable increase in the intensities for mass number 107 and 108, corresponding to element of Ag ( 107 Ag, 109 Ag), was observed. Fig. 6-9 show the normalized intensity for the isotopes of Cr, Fe, Cu and Ag at three areas on the control samples and those after gas penetration both with sputtering. Note that selected areas for the control sample (a, b, c) are different from those analyzed after experiment (A, B, C). As shown in Fig. 6, very low normalized count intensities for mass numbers corresponding to Cr isotopes was found for the control sample, and significant increase for the intensity was observed at all three areas after experiment. For Fe, Cu and Ag isotopes, the normalized intensities were also increased apparently after experiment, as shown in Fig. 7, 8 and 9, respectively. These results suggested that Cr, Fe, Cu and Ag could have been produced during the gas penetration. 3.2 Change in isotopic ratio Most of observed elements have several isotopes and own natural isotopic abundance. A detailed mass number for one of isotopes of an element is sometimes close to that of another element. Therefore, we could not distinguish the count intensities between element 48 Ca and 48 Ti also 50 Ti and 50 Cr by the TOF-SIMS. Thus, We tried to find out the change in ratio of count intensities for isotopes, which mass number have no overlapping with that of other elements. For the case of Ti, the mass numbers for isotopes 47 Ti and 49 Ti have no overlapping with those of other elements. The natural isotopic ratio of 47 Ti to 49 Ti is 0.73 and the value fairly agrees with that for Control sample. In contrast, one of the isotopic ratios of 47 Ti

to 49 Ti for After sample showed a marked change to be 0.94. These ratios for the other two analyzed areas are 0.87 and 0.91, fairly higher than the natural one. For the case of Cr, the mass numbers for isotopes 52 Cr and 53 Cr have no overlapping with those of other elements. The natural isotopic ratio of 52 Cr to 53 Cr is 1.13. The obtained ratios for the three analyzed areas on After sample also gave fairly changes to be 1.25, 1.35 and 1.45, respectively. While, no anomaly of the isotopic ratio was seen for Fe, Cu, Ag and Pd. The ratios both for Control and After samples are consistent with natural ones. The changes in isotopic ratios for Ti and Cr could be the possible evidence of nuclear transmutation in/on Pd foil. Fig. 6 Normalized count intensity for two isotopes of Cr at three areas with 10s sputtering before and after gas penetration.

Fig. 7 Normalized count intensity for two isotopes of Fe at three areas with 10s sputtering before and after gas penetration. Fig. 8 Normalized count intensity for two isotopes of Cu at three areas with 10s sputtering before and after gas penetration.

Fig. 9 Normalized count intensity for two isotopes of Ag at three areas with 10s sputtering before and after gas penetration. 4 Conclusion We performed the hydrogen penetration experiment with Pd sample, and elements on the sample were surveyed for the control sample and that after experiment. Increases in count intensity of TOF-SIMS, corresponding to elements of Ti, Cr, Mn, Fe, Ni, Cu and Ag, have been observed by the hydrogen penetrate through Pd foil. These elements were possibly produced during the gas penetration. V and Co were also detected on deeper regions revealed by the Ga + sputtering for 10s. These elements might have been produced by nuclear transmutation. In the isotopic ratio of Ti and Cr, difference from the natural one was observed in the three analyzed areas of a sample. While, almost no change in isotopic ratio was seen for other elements. The results have strongly suggested that all these elements were produced by a nuclear transmutation and that the reaction could occur in hydrogen system as well as deuterium system. References 1. E. Yamaguchi, T. Nishioka, Jpn. J. Appl. Phys., 29, L 666 (1990) 2. E. Yamaguchi, H. Sugiura, Proceedings of 7-th International Conference on Cold Fusion, p.420 (1998) 3. Y. Iwamura, T. Itoh and M. Sakano Proceedings of 8-th International Conference on Cold Fusion, p.141 (2000). 4. Y. Iwamura, T. Itoh and, M. Sakano, Jpn. J. Appl. Phys., 41, 4642 (2002).

5. J. Dufour, D. Murat. X. Dufour and J. Foos, Proceedings of 8-th International Conference on Cold Fusion, p. 153 (2000). 6. T. Ohmori, H. Yamada, S. Narita and T. Mizuno, Proceedings of 9-th International Conference on Cold Fusion, p. 284 (2002)