Building Kinetic Models for Determining Vitamin C Content in Fresh Jujube and Predicting Its Shelf Life Based on Near-Infrared Spectroscopy

Similar documents
Near Infrared Spectral Linearisation in Quantifying Soluble Solids Content of Intact Carambola

Influence of different pre-processing methods in predicting sugarcane quality from near-infrared (NIR) spectral data

Robust model of fresh jujube soluble solids content with near-infrared (NIR) spectroscopy

NIR Spectroscopy Identification of Persimmon Varieties Based on PCA-SVM

Online Evaluation of Yellow Peach Quality by Visible and Near-Infrared Spectroscopy

Plum-tasting using near infra-red (NIR) technology**

Application of color detection by near infrared spectroscopy in color detection of printing

Nondestructive Determination of Tomato Fruit Quality Characteristics Using Vis/NIR Spectroscopy Technique

Fast Analysis of Superoxide Dismutase (SOD) Activity in Barley Leaves Using Visible and Near Infrared Spectroscopy

ABASTRACT. Determination of nitrate content and ascorbic acid in intact pineapple by Vis-NIR spectroscopy Student. Thesis

PREDICTION OF TOTAL SOLUBLE SOLIDS AND PH IN BANANA USING NEAR INFRARED SPECTROSCOPY

ab83360 Ammonia Assay Kit

Application of Raman Spectroscopy for Detection of Aflatoxins and Fumonisins in Ground Maize Samples

NIR Spectroscopic Properties of Aqueous Acids Solutions

ab83360 Ammonia Assay Kit

Construction of a Ginsenoside Content-predicting Model based on Hyperspectral Imaging

Analysis of Cocoa Butter Using the SpectraStar 2400 NIR Spectrometer

Real-time nondestructive citrus fruit quality monitoring system: development and laboratory testing

Comparison of the HPLC Method and FT-NIR Analysis for Quantification of Glucose, Fructose, and Sucrose in Intact Apple Fruits

MATHEMATICAL MODELING OF VITAMIN C LOSSES IN LEMONS DURING THERMAL TREATMENTS

Design and experiment of NIR wheat quality quick. detection system

Elimination of variability sources in NIR spectra for the determination of fat content in olive fruits

Journal of Chemical and Pharmaceutical Research, 2015, 7(4): Research Article

Quantitative Analysis of Caffeine in Energy Drinks by High Performance Liquid Chromatography

Potential of Near-infrared Spectroscopy to Detect Defects on the Surface of Solid Wood Boards

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Biological and Agricultural Engineering Department UC Davis One Shields Ave. Davis, CA (530)

Vitamin C in Fruit Juices by Redox Titration

Comparison of Four Nondestructive Sensors for Firmness Assessment of Apples

Corresponding Author: Jason Wight,

Journal of Chemical and Pharmaceutical Research, 2015, 7(4): Research Article. Kinetic model of pickles shelf life prediction

Detection of Chlorophyll Content of Rice Leaves by Chlorophyll Fluorescence Spectrum Based on PCA-ANN Zhou Lina1,a Cheng Shuchao1,b Yu Haiye2,c 1

Advanced Spectroscopy Laboratory

Visible-near infrared spectroscopy to assess soil contaminated with cobalt

Introduction. Molecules, Light and Natural Dyes. Experiment

Analysis on Characteristics of Precipitation Change from 1957 to 2015 in Weishan County

Quality. Destructive vs nondestructive methods. Quality attributes. Classes of nondestructive sensors. Optical techniques 11/03/2013

micromachines ISSN X

i-fast validatietraject MOBISPEC

Supplementary Information for

Introduction to Fourier Transform Infrared Spectroscopy

Experiment. Quantification of Ascorbic acid by Fluorescence Spectroscopy1

Prediction of Tangerine Mass Based on Geometrical Properties Using Linear Regression Models

Monitoring the Aggregation of Particles through Raman Spectroscopy

Introduction to Fourier Transform Infrared Spectroscopy

QUALITY AND DRYING BEHAVIOUR OF ORGANIC FRUIT PRODUCTS

Detection of trace contamination on metal surfaces using the handheld Agilent 4100 ExoScan FTIR

Research Article. UV Spectrophotometric Estimation of Alprazolam by second and third order derivative Methods in Bulk and Pharmaceutical Dosage Form

Redox-Responsive Complexation between a. Pillar[5]arene with Mono ethylene oxide Substituents. and Paraquat

Supporting Information

FTIR characterization of Mexican honey and its adulteration with sugar syrups by using chemometric methods

Spectroscopic techniques: why, when, where,and how Dr. Roberto GIANGIACOMO

Extraction Process Validation of Isatis Radix

College of Mechanical Engineering, Yangzhou University, Yangzhou , China; 2

Supporting Information. A novel microporous metal-organic framework exhibiting high acetylene and methane storage capacities

Rapid and nondestructive detection of watercore and sugar content in Asian pear by near infrared spectroscopy for commercial trade

Spectrophotometric Determination of Lorsartan Potassium and its Dosage Form by Bromothymol Blue and Phosphate Buffer

The Application of Classical Least Square Algorithm in the Quantitative Analysis of Lime in Wheat Flour by ATR-MIR Spectroscopy *

Electronic Supplementary Material. Methods. Synthesis of reference samples in Figure 1(b) Nano Res.

Ultraviolet-Visible and Infrared Spectrophotometry

International Journal of Pharma and Bio Sciences

Nondestructive Determination of Tomato Fruit Quality Parameters Using Raman Spectroscopy

A Study on the Application of Near Infrared Hyperspectral Chemical Imaging for Monitoring Moisture Content and Water Activity in Low Moisture Systems

Potable NIR spectroscopy predicting soluble solids content of pears based on LEDs

National standard of People s Republic of China

Rapid Compositional Analysis of Feedstocks Using Near-Infrared Spectroscopy and Chemometrics

Ultraviolet-Visible and Infrared Spectrophotometry

A Comparative Study Concerning Linear and Nonlinear Models to Determine Sugar Content in Sugar Beet by Near Infrared Spectroscopy (NIR)

A sampling approach for predicting the eating quality of apples using visible near infrared spectroscopy

Open Access Measuring Method for Diameter of Bearings Based on the Edge Detection Using Zernike Moment

X-Ray Fluorescent and Mid-Infrared Spectroscopic Measurement of Leaf Model

Analytical Chemistry II

Research Article. Simultaneous spectrophotometric estimation of Paracetamol and Aceclofenac by second order derivative method in combined dosage form

Application of Near Infrared Spectroscopy to Predict Crude Protein in Shrimp Feed

Spectrophotometric Determination of pka of Phenol Red

Optical Sensor in the Measurement of Fruits Quality: A Review on an Innovative Approach

Electronic Supplementary Material

STANDARD OPERATING PROCEDURES

Milk Analysis with the TIDAS P Milk Inspector

Photocatalytic degradation of dyes over graphene-gold nanocomposites under visible light irradiation

One-pot synthesis of bi-metallic PdRu tripods as an efficient catalyst for. electrocatalytic nitrogen reduction to ammonia

College of Life Science and Pharmacy, Nanjing University of Technology, Nanjing, China

Spectroscopic Method For Estimation of Atorvastatin Calcium in Tablet Dosage Form

Water in Food 3 rd International Workshop. Water Analysis of Food Products with at-line and on-line FT-NIR Spectroscopy. Dr.

Putting Near-Infrared Spectroscopy (NIR) in the spotlight. 13. May 2006

Chem Homework Set Answers

Nondestructive Testing and Performance Prediction of Soybean Stalk Board

Application of Near-Infrared Spectroscopy in

Chem 310 rd. 3 Homework Set Answers

Near Infrared reflectance spectroscopy (NIRS) Dr A T Adesogan Department of Animal Sciences University of Florida

Application of Time-of-flight Near-infrared Spectroscopy to Detect Sugar and Acid Content in Satsuma Mandarin

Theoretical comparative study on hydrogen storage of BC 3 and carbon nanotubes

Colorimetric and Fluorescent Dual Detection of Paraquat and Diquat Based on a Novel Anionic Polythiophene Derivative

VISIBLE-NIR INFRARED SPECTROSCOPY FOR POMEGRANATE FRUIT QUALITY ASSESSMENT: CHEMOMETRICS AND COMMON PREPROCESSING METHODS

CHAPTER - 3 ANALYTICAL PROFILE. 3.1 Estimation of Drug in Pharmaceutical Formulation Estimation of Drugs

Validated First Order Derivative Spectroscopic Method for the determination of Stavudine in Bulk and Pharmaceutical Dosage Forms

For Research Use Only

Supporting Information

Fast Detection of Inorganic Phosphorus Fractions and their Phosphorus Contents in Soil Based on Near-Infrared Spectroscopy

Adsorption of Methylene Blue on Mesoporous SBA 15 in Ethanol water Solution with Different Proportions

Transcription:

Sensors 2013, 13, 15673-15681; doi:10.3390/s131115673 Article OPEN ACCESS sensors ISSN 1424-8220 www.mdpi.com/journal/sensors Building Kinetic Models for Determining Vitamin C Content in Fresh Jujube and Predicting Its Shelf Life Based on Near-Infrared Spectroscopy Yaohua Hu 1, Cong Liu 1, Qian Hao 1, Qiang Zhang 2 and Yong He 3, * 1 2 3 College of Mechanical and Electronic Engineering, Northwest A&F University, Yangling 712100, China; E-Mails: huyaohua@nwsuaf.edu.cn (Y.H.); liu_cong19880728@163.com (C.L.); haoqian@nwsuaf.edu.cn (Q.H.) Department of Biosystems Engineering, University of Manitoba, Winnipeg, MB R3T 5V6, Canada; E-Mail: zhang@cc.umanitoba.ca College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China * Author to whom correspondence should be addressed; E-Mail: yhe@zju.edu.cn; Tel./Fax: +86-571-8898-2143. Received: 4 September 2013; in revised form: 20 October 2013 / Accepted: 1 November 2013/ Published: 15 November 2013 Abstract: Fresh jujube (Ziziphus jujube) is rich in vitamin C, which is an important quality index and generally decreases with storage time. The aim of this study was to build kinetic models for determining the vitamin C content, thus predicting the quality characteristics and shelf life of fresh jujube. The quality changes of the jujube stored at room temperature (20 C) were analyzed using near-infrared spectroscopy. The significant spectra were determined and a calibration model for vitamin C content was developed. The results showed that vitamin C content could be described by the zero-order kinetics model based on the regressions. In addition, the shelf life of the jujube at room temperature was calculated according to the regression model. Keywords: fresh jujube; vitamin C content; kinetic model; shelf life; near-infrared spectroscopy

Sensors 2013, 13 15674 1. Introduction Jujube (Ziziphus jujube) has been planted in China for a long time due to its excellent taste and high nutritional value, in particular the vitamin C content. However, the content of vitamin C in fresh jujube decreases sharply upon storage because of decay and oxidation [1], and the loss of vitamin C might be a critical factor for the shelf life of some products [2]. Therefore, it is important to develop rapid, reliable methods to detect the vitamin C in fresh jujube to achieve real-time monitoring in storage. Much research has been reported on the chemical kinetic models of various products during storage, including seafoods, vegetables and juices [3 5]. Some researchers have developed first-order kinetic models for degradation of vitamin C in juice during storage [2]. However, there is little information available in the literature about the kinetics of vitamin C content in fresh jujube during storage. Near-infrared (NIR) spectroscopy has recently attracted a great deal of attention as a non-destructive method for detecting the internal quality of fruits. A vast amount of research has been conducted using NIR spectroscopy to detect the quality of fruits, such as taste characterization in Valencia oranges [6]; soluble solids content (SSC) and firmness in apples [7]; acidity, soluble solids and firmness in Satsuma mandarin [8]; and vitamin C in Navel orange [9]. Van et al. [10] applied kinetic and near-infrared models to describe firmness and moisture loss with time change at constant external condition, respectively. The objectives of this study were: (1) to optimize the NIR spectroscopy model of the vitamin C content of fresh jujube to predict the vitamin C content changes during storage at room temperature; (2) to build a kinetic model of vitamin C content according to NIR spectroscopy and storage time at room temperature; and (3) to predict the shelf life of fresh jujube at room temperature. 2. Material and Methods 2.1. Sample Preparation Seventy-two intact Lizao jujube fruits weighing 25 30 g were hand-harvested from an orchard in Dali, Shaanxi Province, China in the year 2012. The 72 samples were labeled, randomly divided into 18 groups and put on the tray, then stored at room temperature (20 C). The weight of each sample was measured and recorded before spectroscopic measurements. One group of samples was selected every day for the experiment. In other words, the experiment lasted for 18 days since the experiential decay period at room temperature is 15 days). 2.2. Spectral Measurements Spectra were measured by using a Fourier transform near-infrared spectrometer (BRUKER MPA, Ettlingen, Germany) equipped with the OPUS 6.5 optical software. The spectrometer was allowed to warm up for about 30 min, and all spectra were obtained using a fiber optic probe with a wavenumber range of 12,000 4,000 cm 1 at 8 cm 1 intervals and a scan number of 64. A spectral white panel was used as reference to eliminate interference by the light source itself. The samples were divided to 18 groups. Every group had four samples. At the first day, the spectra of 72 samples were obtained, and the four samples of group one were adopted to measure the vitamin C content. At the second day, the

Sensors 2013, 13 15675 spectra of the remaining 68 samples were obtained, and the four samples of group two were adopted to measure the vitamin C content. At the 18th day, only four samples were left. The spectra of the remaining four samples were obtained to measure the vitamin C content. Therefore, the samples of group one have one spectrum, the samples of group two have two spectra, the samples of group three have three spectra, etc. the samples of group eighteen have eighteen spectra. Moreover, three positions of each sample were measured for obtaining spectra. The average spectra of the three positions were adopted to decrease the error. 2.3. Determination of Vitamin C Content of Fresh Jujube The vitamin C content of four jujube samples was measured every day right after the spectral measurement by using the 2,6-dichloroindophenol titration method [11]. The specific steps were as follows: 10 g of pulp of each sample were mashed with 10 ml extraction solvent (2% metaphosphoric acid and 2% oxalic acid), and then the mixture was put into a 100 ml volumetric flask after passing through a filter. One (1) g of activated carbon was added to prevent color interference. Ten (10) ml of filtrate was transferred to a 50 ml conical flask and titrated with 2,6-dichloroindophenol solution until it stayed pink for 15 s. The blank sample was used as reference. The vitamin C concentration was determined by the following equation: VCC = where VCC = vitamin C concentration (mg/100 g); V = dye solutions volume of titrating liquid sample cost (ml); V 0 = dye solutions volume of titrating blank liquid cost (ml); T = 2,6-dichloroindophenol titer (mg/ml); A = dilution multiple; W = sample weight (g). 2.4. Spectral Data Analysis ( V V 0) T A 100 W The spectral data of each jujube measured at three locations were averaged. The pretreatment techniques of Savitzky-Golay smoothing (S-G smoothing, with the smooth points of left and right were 10), multiple scattering correction (MSC), first derivative (1-Der with the smooth points of left and right were 10) and second derivative (2-Der, with the smooth points of left and right were 10) were used to remove and reduce the noises and other measurement errors in the spectra data. In order to identify the optimal pretreat techniques, Savitzky-Golay smoothing (S-G smoothing), first derivative (1-Der), second derivative (2-Der) were compared with the raw spectra by using a statistical software package (Unscrambler 9.8, CAMO, CAMO Software AS, Oslo, Norway). Multivariate linear regression (MLR) was chosen as the near-infrared modeling method. MLR can establish the relationship between the dependent and independent variables with simple calculations and clear physical meaning, and additionally it could be calculated by simply choosing the characteristic wavenumber absorption values corresponding to the composition. At the same time the predictive performance quality can directly reflect the prediction correlation of input variable (spectral data) to the chemical index. This study intends to use regression coefficient (RC) method as wavenumber selection method to choose spectra for ensuring the accuracy of the modeling and the quickness of operation. (1)

Sensors 2013, 13 15676 All fresh jujubes were divided into two sample sets, 50 samples were randomly selected as the calibration (sample) set and 17 samples were randomly selected as the prediction set in the 67 samples (5 decayed samples were eliminated) in this experiment. The calibration sample set was used to establish a stable and reliable model, and the prediction set was used to examine the model performance. 2.5. Development of Model Based on Chemical Kinetics Food quality-related changes are chemical, physical and microbial changes, which can be described by kinetics model chemical reactions. Changes in food quality in storage may be related to the kinetic characteristics, such as the reaction rate constant and activation energy. Most quality food changes follow zero-order or first-order reaction models [12], as described by the following equations: Zero-order reaction: C = C 0 Kt (2) First-order reaction: C = C 0 e Kt (3) where C = quality factor, C 0 = initial value of the quality factor, t = storage time, K = reaction rate constant. Using the NIR model, the initial contents of vitamin C of fresh jujubes were calculated. The kinetic model could be developed based on the predicted initial contents, measured contents and storage time. This was achieved using the statistical program SPSS 18 (IBM, Armonk, NY, USA). 3. Results and Discussion 3.1. Pretreatment of Spectral Dada The MLR technique was used to establish a model to correlate the vitamin C content to the NIR data. The pretreatment techniques such as S-G smoothing, MSC, 1-Der and 2-Der are used to remove the noise and other factors which are included in the spectra [13]. The S-G smoothing and MSC process spectra had a similar curve shapes as the raw spectrum, while the 1-Der and 2-Der processed spectra had different curve shapes from the raw spectrum. The results showed that the spectra with MSC pretreatment technique better predicted the vitamin C content than did other spectra, and the model based on that technique did not show any under-fitting and over-fitting phenomena, and had a small degree of dispersion. Because of sample values changed from 3.250 mg/100 g to 398.287 mg/100 g in storage, the RMSEP was relatively large. This showed that the scattering from the uneven distribution of fresh jujube sample internal particles and particle size had an effect on the near-infrared spectra (Table 1). The MSC was selected as the pretreatment technique. Table 1. Result of different pretreatment technique applied in models. Pretreatment Technique N Rc RMSEC Rp RMSEP Raw Spectra 6 0.876 93.517 0.741 98.117 S-G Smoothing 6 0.878 93.563 0.751 97.826 MSC 6 0.895 90.053 0.708 90.300 1-Der 12 0.942 100.369 0.915 97.653 2-Der 10 0.907 96.684 0.866 95.526 N: The number of characteristic wave number; R: Correlation coefficient; RMSEC: The root mean square error of calibration; RMSEP: The root mean square error of prediction.

Sensors 2013, 13 15677 3.2. Determination of Spectral Regions The absorption peaks were dissimilar due to the difference in functional groups. Six effective wavenumbers in the VNIR (12,000 4,000 cm 1 ) spectra, one in the SW-NIR (12,000 9,091 cm 1 ) spectra, and five in the LW-NIR (9,091 4,000 cm 1 ) spectra were used in the MLR analysis to develop the NIR models (Table 2). The correlation coefficient (R) of the VNIR and LW-NIR spectra models were higher than that in the SW-NIR one. The LW-NIR spectra model was selected for its higher predictability. Also the lower wavenumber is less demanding on the instrumentation, and thus lower cost. The effective wavenumbers were 8,330, 6,900, 5,666, 5,150 and 4,060 cm 1 in the LW-NIR range. The above ranges contain the combination frequencies of symmetric and antisymmetric stretching vibrations of water molecules, including the 10,300, 6,900 and 5,150 cm 1 regions, the relatively weak combination frequency absorption in the 4,710 cm 1 region, whereas the peaks at 5,666 and 4,060 cm 1 are normally attributed to CH and CONH 2 functional groups, respectively [14]. The predictive model for the vitamin C content has the form of: VCC = 1409.098 + 1586.574X 1 + 2145.536X 2 3501.009X 3 277.794X 4 + 30.116X 5 (4) where VCC is the vitamin C content of fresh jujube, and X 1 X 5 are the absorbance of the five effective wavenumbers in the LW-NIR range. The upper bound and lower bounds of the mean value for the 95% confidence interval were 173.683 and 217.234. Table 2. Result of different spectral region in models. Wavenumbers (cm 1 ) N RC RMSEC RP RMSEP 12,000 4,000 6 0.895 90.053 0.708 90.300 12,000 9,091 1 0.099 11.000 0.627 1.028 9,091 4,000 5 0.775 85.735 0.620 76.169 3.3. Change of Vitamin C Content of Fresh Jujube during Storage The spectral curves of fresh jujube displayed obvious changes during storage. The absorbance increased with the storage time and it became a clutter during the last four days (Figure 1). The spectral curves for the 14th, 15th and 18th days were out of order due to the rotten jujubes. Figure 1. Spectra of fresh jujube in 18 days at room temperature.

Vitamin C Content(mg/100g) Vitamin C Content(mg/100g) Sensors 2013, 13 15678 The initial value of vitamin C of fresh jujube at room temperature could be calculated by using the NIR model and the spectra of each fresh jujube from the first day (Figure 2). Based on the measured vitamin C content and the initial value of vitamin C of fresh jujube that was predicted by NIR model, the kinetic models of vitamin C for jujube were determined as follows: Zero order: VCC = 338.787 + 0.044VCC 0 20.677t (5) First order: VCC = 550.58e 0.164t (6) where VCC is the vitamin content in mg/100 g after storing for t days, VCC 0 is the initial vitamin content in mg/100 g, and t is the storage time in days. The upper bound and lower bounds of the mean value for the 95% confidence interval were 150.648 and 201.676. Figure 2. Predicted value of vitamin C of fresh jujubes after 18 days at room temperature. 350 300 250 200 150 100 50 0 Predicted Value of Vitamin C Trend of Vitamin C Change 0 3 6 9 12 15 18 Storage time(day) Figure 3 shows the comparison of the two models. The zero-order reaction model had a higher correlation coefficient than the first-order reaction one (Table 3). It seemed reasonable to conclude that the change of vitamin C content of fresh jujube followed a zero-order kinetics reaction. Figure 3. Kinetics models established by zero-order and first-order reactions. 400 350 300 250 200 150 100 50 Measured Vaule of Vitamin C First-order Reaction Zero-order Reaction SD=105.304 0 0 3 6 9 12 15 18 Storage Time/Day

Sensors 2013, 13 15679 Table 3. Result of kinetics models with vitamin C content of fresh jujubes at room temperature. Items Zero-Order Reaction First-Order Reaction Correlation linear exponent R 0.977 0.782 RMSEC 98.954 130.049 Kinetics Model VCC = 338.787 + 0.044VCC 0 20.677t VCC = 550.58e 0.164t By substituting Equation (4) into Equation (5), the vitamin C content may be predicted directly from the NIR spectroscopy as follows: VCC = 338.787 + 0.044 (1409.098 + 1586.574X 1 + 2145.536X 2 3501.009X 3-277.794X 4 + 30.116X 5 ) 20.677t (7) 3.4. Determination of Safe Storage Time The safe storage time could be predicted by the NIR with the kinetics model. Based on Equation (5), the equation of storage time is as follows: t = 17.128 0.002VCC 0 0.046VCC (8) The maximum shelf life could be considered as 15 days when the vitamin C content decreased to about zero. Combing with NIR model (4), the equation could be described as: t = 17.128 0.002 (1409.098 + 1586.574X 1 + 2145.536X 2 3501.009X 3 277.794X 4 + 30.116X 5 ) 0.046 (1409.098 + 1586.574X 1t + 2145.536X 2t 3501.009X 3t 277.794X 4t + 30.116X 5t ) (9) where X 1 X 5 are the absorbance of the effective wavenumber for fresh jujubes; and X 1t X 5t are the absorbance of the effective wavenumber of spectra for jujubes storage for t days. 4. Conclusions The vitamin C content of fresh jujube stored at room temperature could be predicted by NIR spectroscopy. The NIR model developed with the first derivative technique in the SW-NIR range better predicted the vitamin C content (correlation coefficient of 0.775) than did the S-G smoothing, the 1-Der and the 2-Der methods. The change in vitamin C content of fresh jujube stored at room temperature followed a zero-order kinetics reaction equation, and the correlation coefficient of the kinetic model was 0.977. Combining NIR with storage time the kinetics model could be used as a nondestructive method for determining of the vitamin C content of fresh jujube. The safe storage period could be predicted by applying the NIR kinetics model. The shelf life of fresh jujube when the vitamin C content decreased to about zero at room temperature was 15 days. Acknowledgments This work was supported by the 863 National High Technology Research and Development Program of China (2011AA100705, 2012AA101903), Natural Science Foundation of China (31071332), Zhejiang

Sensors 2013, 13 15680 Provincial Natural Science Foundation of China (Z3090295), China Postdoctoral Science Foundation (2011M501009), the Science and Technology Department of Zhejiang Province (2011C32G2130011) and the Fundamental Research Funds for the Central Universities (2012FZA6005). Conflicts of Interest The authors declare no conflict of interest. References 1. Wang, Y.Q.; Li, J.H.; Zhao, M.; Feng, J.; Wang, C.S. A study on changing law of vitamin C in fresh jujube fruit during storage. Act Agric. Boreali-Sin. 2000, 15, 112 115. 2. Burdurlu, H.S.; Koca, N.; Karadeniz, F. Degradation of vitamin C in citrus juice concentrates during storage. J. Food Eng. 2006, 74, 211 216. 3. Yao, L.; Luo, Y.K.; Sun, Y.Y.; Shen, H.X. Establishment of kinetic models based on electrical conductivity and freshness indictors for the forecasting of crucian carp (Carassius carassius) freshness. J. Food Eng. 2011, 107, 147 151. 4. Giannakourou, M.C.; Taoukis, P.S. Kinetic modelling of vitamin C loss in frozen green vegetablesunder variable storage conditions. Food Chem. 2003, 83, 33 41. 5. Derossi, A.; Pilli, T.D.; Fiore, A.G. Vitamin C kinetic degradation of strawberry juice stored under non-isothermal conditions. LWT Food Sci. Technol. 2010, 43, 590 595. 6. Jamshidi, B.; Minaei, S.; Mohajeraui, E.; Ghassemian, H. Reflectance Vis/NIR spectroscopy for nondestructive taste characterization of Valencia oranges. Comput. Electron. Agric. 2012, 85, 64 69. 7. Bobelyn, E.; Serban, A.S.; Nicu, M.; Lammertyn, J.; Nicolai, B.M.; Saeys, W. Postharvest quality of apple predicted by NIR-spectroscopy: Study of the effect of biological variability on spectra and model performance. Postharvest Biol. Technol. 2010, 55, 133 143. 8. Gomez, A.H.; He, Y.; Pereira, A.G. Non-destructive measurement of acidity, soluble solids and firmness of Satsuma mandarin using Vis/NIR-spectroscopy techniques. J. Food Eng. 2006, 77, 313 319. 9. Xia, J.F.; Li, X.Y.; Li, P.W.; Ma, Q.; Ding, X.X. Application of wavelet transform in the prediction of navel orange vitamin C content by near-infrared spectroscopy. Agric. Sci. China 2007, 6, 1067 1073. 10. Dijk, C.V.; Boeriu, C.; Peter, F.; Smits, T.S.; Tijskens, L.M.M. The firmness of stored tomatoes (cv. Tradiro). 1. Kinetic and near infrared models to describe firmness and moisture loss. J. Food Eng. 2006, 77, 575 584. 11. National Bureau of Standards of China. GB/T 6195 86 Determination of vitamin C in vegetables and fruits (2,6-dichloro-indophenol titration method). 1986. 12. Martinus, A.J.S.; Bookel, V. Kinetic modeling of food quality: A critical review. Food Sci. Food Saf. 2008, 7, 144 158.

Sensors 2013, 13 15681 13. Nicolai, B.M.; Beullens, K.; Bobelyn, E.; Peirs, A.; Saeys, W.; Theron, K.I.; Lammertyn, J. Nondestructive measurement of fruit and vegetable quality by means of NIR spectroscopy: A review. Postharvest Biol. Technol. 2007, 46, 99 118. 14. Workman, J.; Weyer, L. Practical Guide to Interpretive Near-Infrared Spectroscopy; CRC Press: New York, NY, USA, 2009; Volume 8, pp. 226 245. 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).