Highly Sensitive and Rugged GC/MS/MS Tool

Similar documents
Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

Comprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Advantages of Reversed Sandwich Injection for Pesticide Residue Analysis

Workflow Using Hyphenated Mass Spectrometry Techniques

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

Multi-residue analysis of pesticides by GC-HRMS

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ

A Method for Simultaneous Analysis of 174 Pesticides in Grape Using GC-MS/MS

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Sensitive and Repeatable Analysis of Pesticides in QuEChERS Extracts with APGC-MS/MS

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Analysis of Pesticides in Citrus Oil Using a Shimadzu GCMS-TQ8030. No. GCMS No. SSI-GCMS-1404

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Quantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS

Pesticides Analysis Using the Agilent 5977A Series GC/MSD

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Analysis of Terpenes in Cannabis Using the Agilent 7697A/7890B/5977B Headspace GC-MSD System

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing

Simultaneous determination of 74 kinds of pesticides in Chinese herbal medicine listed in Chinese pharmacopoeia (2015) by GPC-GC-MS/MS

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Application Note. Authors. Abstract. Xin Sun Shandong Agriculture University, Taian, , China

Author. Abstract. Introduction

Agilent s New 7000B Quadrupole GC/MS/MS:

Determination of pesticides in baby food by UHPLC/MS/MS using the Agilent 1290 Infinity LC system and the Agilent 6460 triple quadrupole LC/MS

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

Screening for Hundreds of Pesticide Residues Using a GC/Q-TOF with an Exact Mass Pesticide Database in Food

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Analysis of pesticide residues using various GC/MS systems. Radim Štěpán Czech Agriculture and Food Inspection Authority Prague, Czech Republic

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Pesticide Analysis Workflow Using Hyphenated Mass Spectrometry Techniques

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Application Note. Abstract. Authors. Introduction. Food Safety

DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT

USP<467> residual solvents

ENVIRONMENTAL analysis

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Analysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS

Rapid, Robust, and Sensitive Detection of 11-nor-D 9 - Tetrahydrocannabinol-9-Carboxylic Acid in Hair

THE NEW QUANTITATIVE ANALYTICAL METHOD FOR ULTRATRACE SULFUR COMPOUNDS IN NATURAL GAS

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Rugged GC/MS/MS Pesticide Residue Analysis Fulfilling the USDA Pesticide Data Program (PDP) Requirements

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Hints and Tips for APGC Coupled with Xevo TQ-S for Food and Environmental Analysis

U.S. EPA Method 8270 for multicomponent analyte determination

Useful GC/MS Sensitivity for Improved Environmental Analyses. GC/MS Agilent Restricted

UltiMetal Plus Advanced Chemistry for Stainless Steel Surface Deactivation

WADA Technical Document TD2003IDCR

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Application Note GCMS-01 Comparison of Ionization Techniques for the Analysis of Trace-Level Pyrethroid Insecticides by GC-MS/MS

Agilent ESI and APCI sources: for polar to non-polar compounds

Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Food & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada

[application note] INTRODUCTION EXPERIMENTAL. Specimens. Extraction

Validation Report 3 Determination of pesticide residues in cereals by GC-MS/MS (QuEChERS method)

Validation Report Determination of isoprothiolane residues in rice by GC-MS/MS (QuEChERS method)

Food analysis. Solutions for Your Analytical Business Markets and Applications Programs

ApplicationNOTE A STUDY OF THE ANALYSIS OF POLYBROMINATED DIPHENYL ETHER FLAME RETARDANTS BY GC/MS/MS. Introduction. Materials and Methods

Determination of Pesticide Residues in Oats by Automated. QuEChERS and LC/QQQ. Application Note. Abstract. Introduction

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

High Efficiency, Broad Scope Screening of Pesticides Using Gas Chromatography High Resolution Orbitrap Mass Spectrometry

Agilent Bond Elut QuEChERS Food Safety Applications Notebook: Volume 2 INNOVATIVE APPROACHES FOR TODAY S FOOD ANALYSIS CHALLENGES

Simultaneous Compound Identification and Quantification with Parallel Polyarc /FID and MS

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

Ultra-Inert chemistry for Trace Level Analysis

Date ACCURATE-MASS DATABASE FOR SCREENING OF PESTICIDE RESIDUES IN FRUITS AND VEGETABLES BY GAS CHROMATOGRAPHY TIME-OF-FLIGHT MASS SPECTROMETRY

Applying the Agilent 5977A MSD to the Analysis of USP<467> Residual Solvents with the 7697A Headspace Sampler and 7890B GC

Sensitive Detection of 2-MIB and Geosmin in Drinking Water

Determination of Off-Odor Compounds in Drinking Water Using an SPME Device with Gas Chromatography and Mass Spectrometry

Determination of 17 Organotin Compounds in Beverages Using Triple Quadrupole GC-MS/MS System

An Optimal Method for the Analysis of Pesticides in a Variety of Matrices

APPLICATION NOTE. A Capillary Approach to ASTM D3606: Test Method for Determination of Benzene and Toluene in Finished Motor and Aviation Gasoline

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Research of Polychlorinated Biphenyls (PCBs) in Vegetables by GC-MS/MS

Validation Report 18

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Technical Report. Abstract: Pu Wang 1, Huizhong Sun 1, Qinghua Zhang 1, Feifei Tian 2, Lei Cao 2

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

Overview. Introduction

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis

Implementing GC-HRAM MS for More Efficient and Effective Routine Pesticide Residues Analysis

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Anaylsis of Pesticide Residues in Rice Using Agilent Bond Elut QuEChERS AOAC Kit by LC-MS/MS Detection

The Use of Tandem Quadrupole GC/MS/MS for the Determination of Polycyclic Aromatics Hydrocarbons (PAHs) in Food Products

Application Note. Abstract. Authors. Environmental

Determination of 59 potential Allergens in Perfumes by twin-line fast GCMSMS

Application Note S/SL

Transcription:

Highly Sensitive and Rugged GC/MS/MS Tool For Pesticide Multiresidue Analysis in Food Samples Agilent 7 Series Triple Quadrupole GC/MS. The world s first MS/MS designed specifically for GC Analysis

Introduction Your Challenges Multi-residue methods are efficient and cost-effective for analysis of pesticide residues. For methods with a very wide scope, generic sample preparation procedures are usually employed. Inherent to this approach is that clean up of extracts is only possible to a limited extent. When applying such methods to complex matrices like baby food, herbs, spices and tobacco, enhanced selectivity in detection is required to make up for the low selectivity in sample preparation. The analytical challenge is to maximize the number of pesticides, minimize the variety of methods, keep run times short and achieve limits of detection (LOD s) at or below the maximum residue limits (MRLs) which are specified for pesticides under EU legislation. As regulations in the European Union require very low MRLs for pesticide residues, the latest challenge has been to reach part-per-billion level concentrations for hundreds of pesticides in complex matrices, which in turn has required greater sensitivity and efficiency in pesticide screening. Quantitation and confirmation of identity of trace level compounds can be complicated by the matrix, resulting in qualifier ion ratios out of range, or target ions buried in the high chemical background noise. With single quadrupole mass spectrometry, selected ion monitoring (SIM) is often used to improve the detection limit and quantitative reproducibility. In SIM mode, only a few ions are monitored for each target within the retention time (RT) range that the target elutes from the column. SIM may not work well for trace levels in matrix as the interferences in SIM are the same as in full scan mode. Our Integrated Approach Triple quadrupole mass spectrometry allows for drastic reduction or elimination of matrix interferences that limit the accuracy and detection limits of SIM methods. This process, referred to as Multiple Reaction Monitoring (MRM), has two fundamental advantages over SIM. First, detection is based secondary product ion produced by the collisional dissociation of an analyte precursor ion. The analyte precursor ion (isolated in Q by a SIM mechanism) has the same selectivity as SIM, but there is a high probability that at least one of the resultant product ions will be unique to the precursor and not the interference. The increase selectivity of MRM is often apparent by the reduced offset of the baseline as compared to SIM. Secondly, during the mass filtering process in Q, all lower m/z ions from the sample are eliminated. The unique product ions from the collisional dissociation are measured in this zero noise region of the spectrum. The combination of a unique product ions (more selectivity) and the elimination of background noise results in consistently low limits of detection even for complex matrices. This application brief describes the analysis of pesticides in fruit and vegetable extracts using the Agilent 7 Series Triple Quadrupole GC/MS system in MRM mode and in combination with Retention Time Locking 2 and Agilent Capillary Flow Technology to provide backflushing of high-boiling materials. 3 2

Column backflushing is essential for the analysis of complex samples such as food extracts 4 because they usually contain high-boiling indigenous compounds. In just a few runs, these materials can collect on the head of the column, causing peak tailing, retention time shifts and increased chemical noise. Over time, they can migrate from the column to the ionization source, which would eventually have to be cleaned. Agilent's proprietary capillary flow technology makes column backflushing routine and easy to setup for non experts. The method robustness is drastically increased and the analysis cycles are shortened 5. In conclusion the system up-time is maximized allowing significant productivity gains. The need for maintenance is reduced by keeping the chromatographic system and MS ion source cleaner between each injection. Experimental Samples were prepared using the QuEChERS 6 method. QuEChERS stands for Quick Easy, Cheap, Effective, Rugged and Safe and is a food sample preparation for multi-class, multi-residue pesticide analysis. See more at www.agilent.com/chem/quechers Instrumentation The Triple quadrupole GC/MS system used for these experiments are described in Table and shown in Figure. Figure Agilent 789A/7A Triple Quadrupole GC/MS system with the new high capacity 7693 ALS. Instrument conditions Instrumentation GC/MS Triple Quadrupole: Agilent 7A GC: Agilent 789A Inlet: PTV, in splitless mode, µl Injection, Multi-baffle liner 8 C for.5 min, then 5 C/min to 28 C for 2 min Capillary flow technology device: 3-way splitter with analytical column in and restrictor out to the triple quadrupole helium pressure provided by Aux EPC at psi Column: Agilent J&W HP-5ms Ultra Inert 3 m x.25 mm ID,.25 µm HP-5MSUI Restrictor: 8 cm x.8 mm deactivated fused silica Carrier gas: Helium 3.883 psi (constant pressure mode) Oven temperature: 7 ºC ( min), 25 ºC/min to 5 ºC ( min), 3 ºC/min to 2 ºC ( min), 8 ºC/min to 28 ºC ( min) Backflush: Time 5 min, inlet press. psi, Aux EPC 8 psi, oven temp. 28 ºC Retention time locking: Chlorpyrifos-methyl locked to 6.53 min Collision cell gases: N 2 2.6 psi and He 6.25 psi Inert source temperature: 26 C Quadrupole temperature: 5 C Table Instrument conditions. 3

Method Development In order to maximize the response of the instrument for each residue the choice of precursor ion, product ion and collision energy were optimized. The spectra of a typical pesticide in full scan mode (5-5 m/z) e.g. Dicloran (MW = 26) is displayed in Figure 2. The product ion scan spectra of 26 m/z at different collision energy are displayed in Figure 3. x 3 6 5 4 3 2 5 6 7 8 9 2 3 4 5 6 7 8 9 2 2 Counts vs. Mass-to-Charge [m/z] Figure 2 Full scan spectrum of Dicloran under EI ionization mode. Figure 3 Product ion scan of Dicloran for the Precursor (26 m/z ) at different collision energies (5-4 V). 4

The optimum collision energy for the 26>76 transition product ion was found to be at V and the resulting MRM chromatogram is shown in Figure 4. and discussion Figure 5 shows the TIC chromatogram acquired in MRM mode for 36 pesticides. Each MRM segment is indicated by a grey marker line. An enhanced view on a selected part of the analysis with an overlay of all MRM for the compounds in this part is shown Figure 6. The MRM mode allows for accurate quantification of many coeluting analytes as shown between 3.6 and 4.2 minutes. Figure 7 demonstrates the identity confirmation of Diclobenil in a peppermint extract at pg on column using two MRM transitions. The dashed lines indicate the allowed range of the ion ratio as specified in the method. x 6 3 2.5 2.5.5 2.35 2.45 2.55 2.65 2.75 2.85 Counts vs. Acquisition Time [min] Figure 4 MRM chromatogram of Dicloran at ppb. x 4 2..8.6.4.2.8.6.4.2 4 6 8 2 4 6 8 2 22 24 26 28 3 32 34 36 38 4 Counts vs. Acquisition Time [min] Figure 5 Total ion chromatogram of the vegetable extract by GC/MS/MS. x 3 2.4 2..6,2.8.4.5.7.9 2. 2.3 2.5 2.7 2.9 3. 3.3 3.5 3.7 3.9 4. 4.3 Counts vs. Acquisition Time [min] Figure 6 Overlay of extracted MRM transitions. 5

Counts x 2 7. -> 36., 7. ->. 2.4 Ratio=8.7 2.2 2.8.6.4.2.8.6.4.2 -.2 6 6.4 6.8 7.2 7.6 Acquisition Time [min] Figure 7 Two transitions identifying Diclobenil in a peppermint extract at pg on column. The dashed lines indicate the allowed range of the ion ratio. Linearity was also tested with five levels between and 2 ppb for 36 pesticides and Figure 8 shows the calibration curves for Diclobenil and Chlormefos. The correlation coefficients of the external standard calibration curve were.99 on average. The LOD was estimated based on the calculated S/N of the pg standard. For the majority of pesticides, LODs were below 2 pg on column (based on S/N >3: Peak to Peak). Retention time reproducibility was also tested to demonstrate the robustness of the analytical method. Figure 9 shows the outstanding retention time stability of one representative compound: Trifluralin. Calculated %RSD is.36 at 6.73 min for one hundred consecutive injections of lettuce extract into the GC/MS/MS system. Only 3 minute Backflush was necessary to remove all high boiling matrix compounds, the total cycle time for this stability test was 2 hours. Dichlobenil 7 Levels, 7 Levels Used, 7 Points, 7 Points Used, QCs y = 953.8898 * x - 58.738 x 5 R 2 =.9998952 x 5.6.3.6.2 2 4 6 8 24682 Concentration (ng/ml).8.6.4.2 Chlormefos Levels, 7 Levels Used, 7 Points, 7 Points Used, QCs y = 554.7783 * x - 76.5985 R 2 =.999229 2 4 6 8 2 4682 Concentration (ng/ml) Figure 8 Calibration curves showing excellent linearity over the concentration from ppb to 2 ppb range R 2 =.999 respectively for Dichlobenil and Chlormefos. RT [min] 6,5 6,3 6, 6,9 6,7 6,5 6,3 6, 5,99 5,97 Min 6.7 Max 6.75 Mean 6.73 Std Devn.86 % RSD.36 5,95 2 3 4 5 6 7 8 9 Injection Number Figure 9 Exceptional retention time stability of Trifluralin with injections of lettuce extract thanks to column backflushing. 6

Conclusion Agilent s 7 Series Triple Quadrupole GC/MS in combination with the 789 GC is a sensitive and rugged tool for target pesticide analysis in complex matrices. The single multi-residue method we developed also meets the performance and identity confirmation criteria defined by the stringent EU regulations. Excellent selectivity has been achieved to allow unambiguous confirmation of identity for these 36 pesticides even in very complex food matrices and generic sample clean up. Agilent SampliQ QuEChERS kits enable you to prepare food samples for multiresidue, multi-class pesticide analysis with just a few simple steps. For this new GC/MS/MS method, the Agilent Retention Time Locking (RTL) database was used to calibrate the retention times of all pesticides. Therefore, the presented GC/MS/MS method can be easily transferred to other Agilent 7 Series Triple Quadrupole systems with minimum effort and time. References. M. Mezcua, M. A. Martínez-Uroz, P. L. Wylie, and A. R. Fernández-Alba, Simultaneous screening and target analytical approach by GC-q-MS for pesticide residues in fruits and vegetables, Accepted for publication by J. AOAC Int. 2. Bruce D. Quimby, Leonid M. Blumberg, Matthew S. Klee, and Philip L. Wylie, Precise Time-Scaling of Gas Chromatographic Methods Using Method Translation and Retention Time Locking, Agilent Technologies publication 5967-582E. 3. Capillary Flow Technology, more information at http://www.agilent.com/chem/cft 4. Chin-Kai Meng Improving Productivity and Extending Column Life with Backflush, Agilent Technologies publication 5989-68EN. 5. Chris Sandy Improving GC-MS Method Robustness and Cycle Times Using Capillary Flow Technology and Backflushing Agilent Technologies publication 599-3367EN. 6. Limian Zhao, Joan Stevens Analysis of Pesticide Residues in Spinach Using Agilent SampliQ QuEChERS AOAC Kits by GC/MS Agilent Technologies publication 7