Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS

Similar documents
The Agilent 7700x ICP-MS Advantage for Drinking Water Analysis

Trace elemental analysis of distilled alcoholic beverages using the Agilent 7700x ICP-MS with octopole collision/ reaction cell

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Rapid Analysis of High-Matrix Environmental Samples Using the Agilent 7500cx ICP-MS. Application. Author. Abstract. Introduction.

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Simple, reliable analysis of high matrix samples according to US EPA Method 6020A using the Agilent 7700x/7800 ICP-MS

Unmatched Removal of Spectral Interferences in ICP-MS Using the Agilent Octopole Reaction System with Helium Collision Mode Application

Application note. Trace level analysis of sulfur, phosphorus, silicon and chlorine in NMP using the Agilent 8800 Triple Quadrupole ICP-MS

Multi-Element Analysis of Petroleum Crude Oils using an Agilent 7900 ICP-MS

Determination of trace elements in ultrapure semiconductor grade sulfuric acid using the Agilent 8900 ICP-QQQ in MS/MS mode

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Ultra trace measurement of potassium and other elements in ultrapure water using the Agilent 8800 ICP-QQQ in cool plasma reaction cell mode

Analysis of Trace Metal Impurities in High Purity Hydrochloric Acid Using ICP-QQQ

Direct Measurement of Metallic Impurities in 20% Ammonium Hydroxide by 7700s/7900 ICP-MS

Applications of ICP-MS for Trace Elemental Analysis in the Hydrocarbon Processing Industry

Lead isotope analysis: Removal of 204 Hg isobaric interference from 204 Pb using ICP-QQQ in MS/MS mode

Thermo Scientific icap RQ ICP-MS: Typical limits of detection

Direct Analysis of Trace Metal Impurities in High Purity Nitric Acid Using ICP-QQQ

Agilent s New 8800 ICP-QQQ. Transforming ICP-MS Technology

Implementing EPA Method 6020 with the Agilent ICP-MS Portfolio

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

Accurate measurement of elemental impurities in metals and metal alloys using the Thermo Scientific icap TQ ICP-MS

Direct Measurement of Trace Metals in Edible Oils by 7500cx ICP-MS with Octopole Reaction System

Agilent ICP-MS. Fundamentals of ICP-MS Analysis and Its Applications for Low Level Elemental Determination in Cannabis

Techniques for the Analysis of Organic Chemicals by Inductively Coupled Plasma Mass Spectrometry (ICP-MS)

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

Semiquantitative Screening of Pharmaceutical Antiviral Drugs using the Agilent 7500ce ICP-MS in Helium Collision Mode

Thermo Scientific icap TQ ICP-MS: Typical limits of detection

Fergus Keenan Shona McSheehy Julian Wills

Simple and Reliable Soil Analysis using the Agilent 7800 ICP-MS with ISIS 3

Accurate analysis of neptunium 237 in a uranium matrix, using ICP-QQQ with MS/MS

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

High Throughput Water Analysis using Agilent 7900 ICP-MS coupled with ESI prepfast

IMPROVING DATA QUALITY WITH ADVANCED INSTRUMENTATION UTILIZING MULTIPLE INTERFERENCE REDUCTION TECHNOLOGIES

Agilent 8900 Triple Quadrupole ICP-MS

Quantitative analysis of high purity metals using laser ablation coupled to an Agilent 7900 ICP-MS

Sample Analysis Design PART III

Samples compliant with the WATER

Rapid, simple, interference-free analysis of environmental samples using the XSERIES 2 ICP-MS with 3 rd generation CCT ED

Basic and Application Inductively coupled plasma mass spectrometry (ICPMS)

The New Agilent 7700 Series ICP-MS

Sample Analysis Design PART II

Determination of ultratrace elements in photoresist solvents using the Thermo Scientific icap TQs ICP-MS

Analytical Approaches to Arsenic

Analysis of Arsenic, Selenium and Antimony in Seawater by Continuous-Flow Hydride ICP-MS with ISIS

Accurate Analysis of Trace Mercury in Cosmetics using the Agilent 8900 ICP-QQQ

Application. Determination of Trace Metal Impurities in Semiconductor-Grade Hydrofluoric Acid. Authors. Introduction. Abstract.

Ultra-fast determination of base metals in geochemical samples using the 5100 SVDV ICP-OES

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

Trace Analyses in Metal Matrices Using the ELAN DRC II

Elemental analysis of river sediment using the Agilent 4200 MP-AES

Determination of Impurities in Silica Wafers with the NexION 300S/350S ICP-MS

Handling Interferences in the Modern Laboratory with Advanced Triple Quadrupole ICP-MS Technology

Real World Analysis of Trace Metals in Drinking Water Using the Agilent 7500ce ICP-MS with Enhanced ORS Technology. Application. Authors.

Direct Analysis of Photoresist Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Application

Analysis of high matrix samples using argon gas dilution with the Thermo Scientific icap RQ ICP-MS

Agilent ICP-MS Journal September 2009 Issue 39

China Soil Pollution Survey: Elemental Analysis of Soil and Sediment Digests by ICP-MS

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Agilent 8800 Triple Quadrupole ICP-MS: Understanding oxygen reaction mode in ICP-MS/MS

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Analysis of domestic sludge using the Agilent 4200 MP-AES

Fast Analysis of Water Samples Comparing Axially-and Radially- Viewed CCD Simultaneous ICP-OES

Sample Analysis Design Polyatomic Interferences

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Total Elemental Analysis of Food Samples for Routine and Research Laboratories, using the Thermo Scientific icap RQ ICP-MS

ICP-MS Analysis of Bulk & Process Chemicals for Semiconductor Processes. Ann O Connell Chemical Analysis Eng Intel Corporation

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Performance of the Agilent 7900 ICP-MS with UHMI for high salt matrix analysis

ICP-MS. plasma 17OO. High Resolution Multi-Collector ICP-MS.

Analytical Methods. Electronic Supplementary Information File

Determination of Trace Metals in Human Urine Using the NexION 300 ICP-MS

Application Note. Authors. Abstract. Introduction. Environmental

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Simplified workflows for the Thermo Scientific icap TQ ICP-MS

Advanced ICP-MS techniques for overcoming interferences in LA-ICP-MS bioimaging

High-Throughput Semiquantitative Screening of Ambient Air Samples by ORS-ICP-MS and Integrated Sample Introduction System (ISIS) Application

Application note. Accurate determination of sulfur in biodiesel using Isotope Dilution-Triple Quadrupole ICP-MS (ID-ICP-QQQ) Petrochemical

Lecture 7: Atomic Spectroscopy

Total elemental analysis of food samples for routine and research laboratories using the Thermo Scientific icap RQ ICP-MS

Application of the Agilent 7900 ICP-MS with Method Automation function for the routine determination of trace metallic components in food CRMs

Author. Abstract. Introduction

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Analysis of noble metals at low levels in geological reference materials and ores

4.1 Atomic structure and the periodic table. GCSE Chemistry

Application note. Determination of exchangeable cations in soil extracts using the Agilent 4100 Microwave Plasma-Atomic Emission Spectrometer

Partial Energy Level Diagrams

Agilent s Solutions for Nanoparticles Analysis ICP-MS, ICP-MS/MS, software. Alain Desprez Agilent Technologies

Determination of Phosphorus and Sulfur with Dynamic Reaction Cell ICP-MS

Single particle analysis using the Agilent 7700x ICP-MS

Chapter 4 Reactions in Aqueous Solution

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Agilent Technologies at TIAFT 2013

Particle Behavior of Light 1. Calculate the energy of a photon, mole of photons 2. Find binding energy of an electron (know KE) 3. What is a quanta?

Low Level Phosphorus: A Method Comparison Study

Validating performance of an Agilent 7800 ICP MS for USP <232>/<233> & ICH Q3D/Q2(R1): Elemental Impurity Analysis in Pharmaceuticals

Transcription:

Comparing Collision/Reaction Cell Modes for the Measurement of Interfered Analytes in Complex Matrices using the Agilent 7700 Series ICP-MS Technical Overview Abstract Inductively coupled plasma mass spectrometry (ICP-MS) is a key analytical tool in many laboratories. It is used for elemental determinations across a wide range of analyses, including environmental, semiconductor, food safety, geological, chemical, petrochemical, nuclear, clinical, forensic, and research applications. Since the early publications during the development of ICP-MS, it has been apparent that one of the key limitations of the technique was the presence of molecular ions that overlap the preferred isotopes of several analytes. These molecular ions are typically called "polyatomic" ions, and are derived from combinations of the elements present in the plasma, the solvent and the sample matrix. Strategies for reducing, removing or correcting for these polyatomic interferences vary, but most of the emphasis over the past 10 years has been on using collision/reaction cell (CRC) technology to selectively reduce the transmission of the interfering ions, thereby reducing the contribution of the interference at the analyte mass. Many publications have presented methods where a specific reaction gas is used to separate single, known interferences from single analyte isotopes. While this is of undoubted academic interest, the removal of a single, known interference from a single analyte is not relevant for the majority of real applications, where ICP-MS is used to determine multiple analytes in a range of complex and unknown sample matrices. This study compared no gas, reaction and collision s for the measurement of multiple interfered analytes in the complex and variable matrices that are typically analyzed in many laboratories. The data demonstrate the superior performance achieved with helium (He) collision in the 3rd generation Octopole Reaction System (ORS 3 ) of the Agilent 7700 Series.

Introduction The Agilent 7700 Series ORS 3 is the culmination of development work that started with the original ORS, introduced on the Agilent 7500c ICP-MS in 2001. Conceived as a reaction cell, using H 2 cell gas to selectively remove intense interferences on interfered elements such as 40 Ca (overlapped by Ar), 56 Fe (overlapped by ArO) and 80 Se (overlapped by Ar 2 ), the ORS was also designed to operate in collision, using He cell gas. It quickly became apparent that He combined with interference removal by kinetic energy discrimination (KED) offered several key benefits, especially for the analysis of complex and variable samples. However, the ORS of the 7500c could not match the sensitivity specification of non-cell instruments, due to the use of an off-axis cell configuration, designed to protect the cell from matrix contamination. Subsequent developments led to the second generation ORS, used in the Agilent 7500ce, launched in 2004. With this development, the focus was on increasing ion transmission, while also improving robustness for high matrix sample analysis. This was achieved by moving the cell to an on-axis configuration, and placing an off-axis ion lens in front of it. The off-axis lens removes contaminants (such as neutrals and photons) prior to the cell, improving matrix tolerance and long-term stability. The ORS 3 has been developed to maximize the capability of He, allowing this simple and consistent to be applied to a wider range of analytes and sample types than ever before. In most common applications (with the exception of semiconductor), the use of reactive cell gases is no longer required, with all the benefits for method development and routine operation that this provides. Much of the published work relating to collision/reaction cell (CRC) technology has focused on removing well-characterized interferences by adding a specific reaction gas to the cell. This approach has three important limitations, which are rarely addressed in the published work: 1) Each reaction gas will only remove interferences which react with that gas. If several matrix-based polyatomic interferences occur at the same analyte mass, not all the polyatomics will react with the selected cell gas, so some residual interferences remain. In the same way, reaction gases are rarely suitable for multi-element analysis, because different analytes suffer overlap from different interferences, not all of which will react with the chosen cell gas. 2) All reaction gases will react with matrix, interference and analyte ions, to create new cell-formed reaction product ions; these may appear as new interferences on other analytes, and the new interferences will vary depending on the sample matrix. 3) Any reactive cell gas will react with some of the analyte ions, as well as the target polyatomic(s). This causes signal loss for the analyte(s), degrading detection limits. The comparative tests discussed here investigate the practical effect of these potential issues, and assess which, collision or reaction, is more effective for multi-element analysis in a complex sample matrix. The matrices in which the tests were carried out are detailed in Table 1. Table 1. Individual Matrices and Combined Mixed Matrix Composition Matrix component Solution used N 5 % HNO 3 Cl 5 % HCl S 1 % H 2 SO 4 C 1 % methanol Na 200 ppm Na Ca 200 ppm Ca P 500 ppm P Mix All of the above The mixed matrix was developed as a result of a contract laboratory ICP-MS evaluation, in which samples of many different matrices were provided for analysis. The matrices covered a range of typical environmental sample types, including soil extracts, waste waters, trade effluents, leachates and "oneoff" samples, such as rainwater runoff and delivery tanker washout samples. All of the matrix components in the mixed matrix sample were present at comparable levels in one or more of the sample types evaluated by this laboratory, and all may be present at variable and unknown levels in many common sample types. Therefore, this analysis provides a tough but very realistic test for any ICP-MS instrument. Further matrix components may be added (such as Si, K, Al, etc), but each additional matrix component increases the possibility of adding trace levels of the analytes of interest, as contaminants in the matrix. Analytes Since ICP-MS is most typically used for multi-element analysis, our investigation focused on all of the elements in the mass range from 45 to 80, which represents the most interfered region of the ICP-MS spectrum in most sample types. This mass range covers all the preferred isotopes of all the analytes from Sc (mass 45) to Se (mass 78). A full list of the elements measured and the isotopes used is given in Table 2. 2

Matrix Components Table 2 also lists the potential polyatomic interferences which might arise in the complex mixed matrix described in Table 1. It should be noted that at least one polyatomic interference can occur on every isotope of every element in this mass range, and also that the various polyatomics which overlap each analyte mass typically arise from different matrix components. This is the main reason why single-element and single-matrix tests of CRC performance are largely irrelevant. Isotope Principal Interfering Species (mixed matrix) 45 Sc 13 C 16 O 2, 12 C 16 O 2 H, 44 CaH, 32 S 12 CH, 32 S 13 C, 33 S 12 C 47 Ti 31 P 16 O, 46 CaH, 35 Cl 12 C, 32 S 14 NH, 33 S 14 N 49 Ti 31 P 18 O, 48 CaH, 35 Cl 14 N, 37 Cl 12 C, 32 S 16 OH, 33 S 16 O 50 Ti 34 S 16 O, 32 S 18 O, 35 Cl 14 NH, 37 Cl 12 CH 51 V 35 Cl 16 O, 37 Cl 14 N, 34 S 16 OH 52 Cr 36 Ar 16 O, 40 Ar 12 C, 35 Cl 16 OH, 37 Cl 14 NH, 34 S 18 O 53 Cr 36 Ar 16 OH, 40 Ar 13 C, 37 Cl 16 O, 35 Cl 18 O, 40 Ar 12 CH 54 Fe 40 Ar 14 N, 40 Ca 14 N, 23 Na 31 P 55 Mn 37 Cl 18 O, 23 Na 32 S, 23 Na 31 PH 56 Fe 40 Ar 16 O, 40 Ca 16 O 57 Fe 40 Ar 16 OH, 40 Ca 16 OH 58 Ni 40 Ar 18 O, 40 Ca 18 O, 23 Na 35 Cl 59 Co 40 Ar 18 OH, 43 Ca 16 O, 23 Na 35 ClH 60 Ni 44 Ca 16 O, 23 Na 37 Cl 61 Ni 44 Ca 16 OH, 38 Ar 23 Na, 23 Na 37 ClH 63 Cu 40 Ar 23 Na, 12 C 16 O 35 Cl, 12 C 14 N 37 Cl, 31 P 32 S, 31 P 16 O 2 64 Zn 32 S 16 O 2, 32 S 2, 36 Ar 12 C 16 O, 38 Ar 12 C 14 N, 48 Ca 16 O 65 Cu 32 S 16 O 2 H, 32 S 2 H, 14 N 16 O 35 Cl, 48 Ca 16 OH 66 Zn 34 S 16 O 2, 32 S 34 S, 33 S 2, 48 Ca 18 O 67 Zn 32 S 34 SH, 33 S 2 H, 48 Ca 18 OH, 14 N 16 O 37 Cl, 16 O 35 2 Cl 68 Zn 69 Ga 70 Zn 71 Ga 32 S 18 O 2, 34 S 2 32 S 18 O 2 H, 34 S 2 H, 16 O 37 2 Cl 34 S 18 O 2, 35 Cl 2 34 S 18 O 2 H, 35 Cl 2 H, 40 Ar 31 P 72 Ge 40 Ar 32 S, 35 Cl 37 Cl, 40 Ar 16 O 2 73 Ge 40 Ar 32 SH, 40 Ar 33 S, 35 Cl 37 ClH, 40 Ar 16 O 2 H 74 Ge 40 Ar 34 S, 37 Cl 2 75 As 40 Ar 34 SH, 40 Ar 35 Cl, 40 Ca 35 Cl, 37 Cl 2 H 77 Se 40 Ar 37 Cl, 40 Ca 37 Cl 78 Se 40 Ar 38 Ar 80 Se 40 Ar 2, 40 Ca 2, 40 Ar 40 Ca, 32 S 16 2 O, 32 S 16 O 3 Table 1. Analytes measured in matrix tests, together with possible polyatomic overlaps derived from the mixed matrix solution. Highlighted isotopes are preferred analytical masses. Instrumentation: Tuning and Data Acquisition The Agilent 7700x was used to measure each sample in each of the 3 s (no gas, helium and hydrogen), using standard Agilent-recommended autotuning for robust tuning conditions (around 1.0 % CeO/Ce). In addition to the use of consistent sample introduction parameters and plasma conditions, consistent ion lens, cell gas flow rate and cell voltage settings were used for the measurement of all of the analytes and matrices within each cell. Standard cell gas flow rates and KED bias voltages were used in each. A method was defined with all three cell gas s run in the following order: no gas, H 2, He. The sample sequence was prepared, with a two-point multi-element external calibration at 0 ppb and 10 ppb, stabilized with 0.1 % HNO 3 (the zero matrix calibration reference). All the remaining blank (unspiked) matrices were then measured against this external calibration. No internal standards were used. Each sample was measured only once, with the system switching between cell s during the acquisition for each sample. The standard Agilent multistep rinse program was used, in conjunction with pre-emptive rinse. Results and Discussion The concentration of each analyte in each matrix was calibrated against the standards in 0.1 % HNO 3, and the measured concentrations in each cell gas were plotted against the matrix name. This gave a series of comparison plots, showing the background equivalent concentration (BEC) for each analyte in each gas, plotted against the matrix. Since all the samples in these plots were unspiked matrices, all the results should have been zero, so any positive result indicates the presence of a polyatomic interference or trace contamination of that analyte in the matrix. Example plots are shown, illustrating the typical performance observed. Removal of Matrix-Based Interferences Figure 1 shows the BEC for As (measured at mass 75) in each gas, plotted against each matrix. As might be expected, the no gas data showed a high apparent concentration of As in the 5 % HCl matrix, due to the interference from ArCl which contributes to the signal at mass 75. The apparent As concentration in no gas was much higher in the mixed matrix (the final point on the x-axis), than in the HCl alone (about 27 ppb, compared to about 11 ppb). This is because 3

the mix contained the Ca from the 200 ppm Ca solution, as well as the Cl from the 5 % HCl. This new combination led to the formation of a new CaCl polyatomic interference on As, which was not present in any of the single-component solutions. By contrast, the results for As in He were consistently at a low level in all the single matrices and the mix, indicating effective removal of both the ArCl and the CaCl interferences in these unspiked matrices. Figure 1 shows that the ArCl interference was also removed effectively in reaction (H 2 cell gas), since ArCl is highly reactive with H 2. However, while H 2 removed the ArCl interference on As, it did not completely remove the CaCl, illustrating the point that not all of the interferences at any given analyte mass may react with the same reaction gas. This comparison highlights a common problem of reactive cell gases, where a method may be developed using one specific sample type, but then the chosen reaction gas fails to remove interferences successfully in routine use, where the unknown sample matrices do not match the original sample type. As shown in Figure 2, a similar comparison can be observed for 47 Ti (which suffers from polyatomic interferences from PO and CCl), and 59 Co (CaO/CaOH), 60 Ni (CaO/CaOH) and 63 Cu (ArNa) also suffered from residual interferences in H 2. All of these interferences were effectively removed in He. 75 As CaCl interference in no gas is not completely CaCl is not very reactive with H 2 cell gas, so residual interference remains ArCl removed in He or H 2 ArCl CaCl CaCl not completely Figure 1. Comparison plot of 75 As BEC vs sample matrix for three cell s. 4

47 Ti PO and CCl interferences in no gas are not completely PO and CCl are not very reactive with H 2 cell gas, so residual interference remains. PO, CCl not completely PO not completely Figure 2. Comparison plot of 47 Ti BEC vs sample matrix for three cell s. Creation of New Cell-Formed Interferences For some combinations of analyte and matrix, another important problem of reactive cell gases was observed, as illustrated in Figure 3 for 45 Sc in the Ca matrix. 45 Sc CO 2 /CO 2 H interferences are removed in He. But H 2 does not remove CO 2 /CO 2 H and creates new interference on 45 Sc in Ca matrix due to formation of new CaH overlap. CO 2, CO 2 H CaH Figure 3. Comparison plot of 45 Sc BEC vs sample matrix for three cell s. 5

In no gas, a polyatomic interference was observed on Sc in the 1 % acetic acid matrix, due to the formation of CO 2 and CO 2 H interferences. These interferences were reduced but not completely. It is possible that the CO 2 was reduced, but through a reaction process that led to an increase in CO 2 H. However, in the Ca matrix, the level of polyatomic interference on Sc was very low in no gas and He, but much higher when H 2 cell gas was used. This is because H 2 reacts with Ca to form a new cell-formed reaction product ion, 44 CaH, greatly increasing the interference on 45 Sc. By contrast, the apparent Sc concentration measured in He was low and consistent in all the single matrix blanks and in the mix, again illustrating effective removal of all the polyatomic interferences in He. He is inert, so no new polyatomic ions are formed in the cell, regardless of the sample composition. As shown in Figure 4, a similar pattern was observed for 65 Cu (S 2 H and SO 2 H), and 51 V and 52 Cr were also affected by the creation of new cell-formed polyatomic ions (SOH on 51 V, and ClOH on 52 Cr), which led to an increased level of interference in H 2 compared to no gas. All of these interferences were removed effectively in He. Loss of Analyte Sensitivity Due to Reaction with Cell Gas The third potential issue with reaction is the loss of analyte sensitivity as a result of the analyte ions reacting with the cell gas. This effect is partly responsible for the very poor performance seen for Cu in H 2, and is illustrated more clearly in Figure 5. Figure 5a shows that in no gas, without any added matrix, the spectrum of transition elements reflected the relative intensities expected from the natural isotopic abundance and degree of ionization of each element. 65 Cu Cu sensitivity decreases a lot in H 2 (due to reaction with H 2 ), and new SO 2 H and S 2 H interferences are formed in H 2. Result is 65 Cu BEC in H 2 is 10 times poorer than in no gas. S 2 H, SO 2 H S 2 H, SO 2 H, NOCl, COCl, N 2 Cl Figure 4. Comparison plot of 65 Cu BEC vs sample matrix for three cell s. 6

In He (Figure 5b), this general pattern of peak intensities was maintained, although with a slight increase in mass bias (lower transmission for lighter elements), due to scattering of the lighter ions. In He, the intense peaks from ArO and Ar 2 interferences (the highest peaks in the no gas spectrum) were also removed, so the 56 Fe and 78 Se/ 80 Se isotopes also matched the expected abundances. After correction for mass bias, isotopic abundance and degree of ionization, all the peaks in the He spectrum would lie on a consistent "mass/response" curve. This allows reliable calibration in semiquantitative analysis, where uncalibrated elements are quantified by reference to their response relative to a few calibrated elements across the mass range. In H 2 (Figure 5c), by contrast, the peak pattern was completely different from the reference spectrum in no gas. The relative intensities of the Ni and Cu peaks in particular were dramatically lower, but also the V, Cr, Co, As and, to a lesser extent, Fe, were all reduced compared to the ArO NoGas Mode - 10 ppb in HNO 3 Ar 2 Figure 5a. Relative sensitivity for analytes from Sc to Se in no gas. He Mode - consistent sensitivity peak pattern is same as no gas (but without the ArO and Ar 2 interferences!). He Mode - 10 ppb in HNO 3 Figure 5b. Relative sensitivity for analytes from Sc to Se in He. H 2 Mode - severe signal loss for V, Cr, Fe, Co, Ni, Cu and As peak pattern is very different from no gas. H 2 Mode - 10 ppb in HNO 3 Figure 5c. Relative sensitivity for analytes from Sc to Se in H 2 (reaction). 7

pattern observed in no gas. It is clear that no reliable mass/response curve could be fitted to this data, as the loss of sensitivity was so different between adjacent analytes. This comparison highlights other key benefits of He, which are that it simplifies method setup and improves the quality of data obtained by semiquantitative calibration. H 2 does not maintain a consistent relationship between different analytes and cannot therefore be used successfully for semiquant or "non-specific" calibration. In terms of the actual sensitivity loss, the signal reduction for Cu in H 2 is of the order of 95 to 99 %. This dramatic and variable loss of analyte sensitivity by reaction is another reason why reactive cell gases are not commonly used for multi-element applications. For More Information For more information on our products and services, visit our Web site at www.agilent.com/chem/icpms. Conclusions In the investigations discussed, it has been shown that several serious problems can occur when H 2 cell gas is used during the measurement of the first row transition elements in a complex matrix. These problems are: 1) Failure to remove unreactive polyatomic ions, leading to residual interferences 2) Creation of new, cell-formed reaction product ions 3) Loss of sensitivity for several analytes, due to reaction with the cell gas. The net result of these three problems is that He is not only simpler and more consistent in operation, but also generates more reliable data than H 2 for multi-element analysis of complex samples under a single set of operating conditions. www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 2009 Printed in the USA August 28, 2009 5990-3236EN