centro tecnológico Development of reference materials: a case study on packaging material as a source of taints in foods

Similar documents
17. July 2018 / 07:49 PO No / Order of General tests Marabu GmbH & Co. KG, Mr. Düzgün Chilbuka Marabu GmbH & Co.

Schedule for a proficiency test

Unit 2: Practical Scientific Procedures and Techniques

ISO/IEC requirements. General matters of quality system, requirements for documentation and the list of the documents required for a

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Validation of analytical methods. Adrian Covaci Toxicological Center, University of Antwerp

Test Report. No. NGBHG Date: 21 Nov Page 1 of 10.

Annex 2 Formaldehyde

5 th GRADE PHYSICAL AND CHEMICAL TESTS

mocon s Shelf Life Studies Alan Shema Product Manager Consulting & Testing Services Basics Concepts Principles Advanced Packaging Solutions

Application. Air : Food :

TECHNICAL BRODIFACOUM

Protocol for the design, conducts and interpretation of collaborative studies (Resolution Oeno 6/2000)

Supplementary information 1. INSTRUCTIONS FOR STUDENTS

The missing link sensory and rheology study of low fat stirred yoghurt

The World Bank CG Rep. LISUNGI Safety Nets System Project (P145263)

Basic Polymer Technology

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

TECHNICAL TEMEPHOS. 1. Specification. Full specification WHO/SIT/19.R4 Revised 10 December Description

GENERAL INSTRUCTIONS

What is measurement uncertainty?

Physical Science Review Sheet Matter & Physical Properties

STANDARD PROCEDURE: NWSP R2 (15) Polyacrylate Superabsorbent Powders Determination of the Particle Size Distribution by Sieve Fractionation

PILOT OF AN EXTERNAL QUALITY ASSURANCE PROGRAMME FOR CRYSTALLINE SILICA

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction

Validation and Standardization of (Bio)Analytical Methods

CCME Reference Method for the Canada-Wide Standard for Petroleum Hydrocarbons (PHC) in Soil - Tier 1 Method

IDENTIFICATION AND DETERMINATION OF HYDROQUINONE IN COSMETIC PRODUCTS 2 14/11/17 ACM 003 BY TLC AND HPLC

Working with Hazardous Chemicals

Preparation of Viscous Solutions. Quantitative wet lab; students work in pairs and individually.

Functional Genomics Research Stream. Lecture: February 17, 2009 Masses, Volumes, Solutions & Dilutions

Standard Practice for Heat Aging of Plastics Without Load 1

LAP-013. Procedure Title: Date: 6/28/96. Author: Raymond Ruiz and Tina Ehrman ISSUE DATE: 8/26/96 SUPERSEDES: 11/01/94.

GCSE Chemistry. Module C7 Further Chemistry: What you should know. Name: Science Group: Teacher:

Report on the 2011 Proficiency Test for the determination of T-2 and HT-2 toxins in wheat flour

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

DRAIN TRACING DYE RED E123

Rosemary extract liquid

MiSeq System. Denature and Dilute Libraries Guide

VOC TEST REPORT M1. 23 October Regulation or protocol Conclusion Version of regulation or protocol

SWGDRUG GLOSSARY. Independent science-based organization that has the authority to grant

INTERNATIONAL CONFERENCE ON HARMONISATION OF TECHNICAL REQUIREMENTS FOR REGISTRATION OF PHARMACEUTICALS FOR HUMAN USE

Cadmium and lead content

Physical adsorption of PVOH to adjust the rheological profile of NFC

TEAC Green Procurement Guideline

RIDASCREEN Aflatoxin M 1

Total, active and effective alkali

Reference Materials for Trade and Development: Quality and Comparability

OF ANALYSIS FOR DETERMINATION OF PESTICIDES RESIDUES IN FOOD (CX/PR 15/47/10) European Union Competence European Union Vote

Test Report. Glava AS. Emission test of Ecophon Venus according to M1 classification. October / November Smedeskovvej 38, DK-8464 Galten

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

Procedure for Body Fluid Unit Quality Control

METHOD 3520C CONTINUOUS LIQUID-LIQUID EXTRACTION

12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP))

GENERAL INSTRUCTIONS GENERAL PREPARATION

Angelina College Science and Mathematics Chemistry 1105 Introductory Chemistry Internet General Syllabus

THIRD GRADE WATER 1 WEEK LESSON PLANS AND ACTIVITIES

Total sulphur content

Recommended Practices in Essential Oil Research

Water Soluble Polymers For Industrial Water Treatment Applications

Laboratory Performance Assessment. Analysis of Analytes in Dried Apple Chips. Report

APPENDIX G EVALUATION OF MEASUREMENT UNCERTAINTY

VOC TEST REPORT M1. 6 April Regulation or protocol Conclusion Version of regulation or protocol

The analysis of organic acid content of additives, premix, feed, and water.

Gluten (Gliadin) Lateral Flow IIR

Sample Preparation of Electronic Device Components for Hexavalent Chromium Analysis by IEC Method :2017

Sodium Chloride - Analytical Standard

CHEK Proficiency study 642. Migration of formaldehyde from melamine kitchenware. Date 7 July 2016 Version 1 Status Final Report number CHEK

Control Standard for Handling Chemical Substances in Products, Parts and Materials

Friedel Crafts Reaction: Alkylation of Xylene, Kinetic and Thermodynamic Reactions Part I Kinetic Control

Technical note on seasonal adjustment for M0

[ Care and Use Manual ]

Eppendorf UVette. Instructions for use

Nucleophilic displacement - Formation of an ether by an S N 2 reaction The Williamson- Ether Synthesis

Typical Hydrologic Period Report (Final)

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

MOHAWK COLLEGE OF APPLIED ARTS AND TECHNOLOGY CHEMICAL AND ENVIRONMENTAL TECHNOLOGY DEPARTMENT. Lab Report ROOM NO: FE E309

Statistical Reports in the Magruder Program

ept.i.p.s. pipette tips are available with various degrees of purity, with and without filters, and as special tips.

APPENDIX G ESTIMATION OF UNCERTAINTY OF MEASUREMENT

METHOD 9079 SCREENING TEST METHOD FOR POLYCHLORINATED BIPHENYLS IN TRANSFORMER OIL

2018 Version. Separating Mixtures Junior Science

Development of a European standard for the determination of acid potential and neutralisation potential of sulfidic waste

What is Science? Science is both a collection of knowledge and the process for building that knowledge.

SPME-GC-MS/MS for Identification and Quantification of Migration Contaminants in Paperboard Food Packaging

Convenor: Colin Fricker Co-convenor: Olivier Molinier Objective of the revisionof ISO 13843

Introduction to Strong and Weak Acids

Fragrances Sampling and Analysis

Basic Digestion Principles

CHM 130 Physical and Chemical Changes

METHOD 9252A CHLORIDE (TITRIMETRIC, MERCURIC NITRATE)

1.Critique the selection of foods to promote a healthy lifestyle

+ H 2 O Equation 1. + NaOH CO 2 Na

METHOD 13B - DETERMINATION OF TOTAL FLUORIDE EMISSIONS FROM STATIONARY SOURCES (SPECIFIC ION ELECTRODE METHOD)

Test Method Development and Validation as Pertaining to Microtrac Particle Size Measuring Instruments

M1 Test Report. 1 Sample Information. 2 Evaluation of the Results. Report No A_04

Aquagent. The Scharlau comprehensive pyridine-free solutions range for a reliable Karl Fischer Titration

Transcription:

centro tecnológico

ESN CONFERENCE: SENSORY ANALYSIS. MORE THAN JUST FOOD Session 5: Proficiency testing in sensory analysis. Development of reference materials: a case study on packaging material as a source of taints in foods.

INTRODUCTION - Proficiency testing. Test material. - Sensory analysis of packaging CASE STUDY: CALIBSENSORY project - creation of calibration material - feasibility of use of calibration material

PROFICIENCY TESTING IN SENSORY ANALYSIS Most of the sensory laboratories concern about validity of their work in an internal way but, what about checking validity of results externally? Proficiency testing: based on the use of inter-laboratory test comparisons to determine the performance of individual laboratories for specific tests. Gives a laboratory independent information about performance of its sensory panel compared to other panels.

SENSORY EVALUATION OF PACKAGING MATERIAL Food packaging materials should not smell or cause off-flavour in packed food. The Regulation (EC) No 1935/2004 related to materials intended for contact with foodstuffs implies that materials must not transfer their constituents to foodstuffs in quantities which could bring about an unacceptable deterioration in organoleptic characteristics. Available standards about sensory testing of packaging material related to transference of taints to foodstuff: DIN 10955, Robinson test, EN 1230, ISO 13302, ASTM standards (E619 84, E460 88, E462 84,.. )

EN 1230-1: Paper and board intended for contact with foodstuffs Sensory analysis part 1: Odour. board board ODOUR TEST Assessment of inherent odour of the packaging material: the packaging material under test is stored in a container under controlled conditions. The odour of the atmosphere developed upon confinement is assessed by means of sensory analysis methods. EN 1230-2: Paper and board intended for contact with foodstuffs Sensory analysis part 2: Off-flavour (taint). board OFF-FLAVOUR TEST Assessment of the effect of the packaging material on the flavour of the foodstuff: The foodstuff and the packaging material under test, with direct or indirect contact, are stored in a container under controlled conditions. The flavour changes of the foodstuff are assessed by means of sensory analysis methods.

Several sensory methods for testing packaging material (both odour test and off-flavour test): paired comparison test, triangle test, duo-trio test, extended triangle test, ranking test, scoring test (multiple comparison test). Common sensory method: scoring the intensity of the odour or off-flavour according to a five-point scale: 0 no perceptible off-odour / no perceptible off-taste 1 off-odour just perceptible / off-taste just perceptible 2 weak off-odour / weak off-taste 3 clear off-odour / clear off-taste 4 strong off-odour / strong off-taste (DIN 10 955 scale)

Subjective interpretations of descriptions such as weak or strong. Different results from panel to panel, and even to different individuals. For helping in anchor the term slight or strong: specific reference standard that shows this lower level versus a stronger level. Standards do not include instructions of how to calibrate the measurement tool and/or how to use any reference materials. Need for common means for calibration of the testing method. CALIBSENSORY Calibration of sensory testing of food contact materials paper and board Project funded by the European Community under the Competitive and Sustainable Growth Programme (1998-2002)

REREFENCE MATERIAL Reference material is a material or substance one or more of whose property values are sufficiently homogeneous, stable, and well established to be used for the calibration of an apparatus, the assessment of a measurement method, or for assigning values to materials (ISO Guide 30:1992). to help develop accurate methods of analysis Reference material is used: to calibrate measurements systems to assure the long-term adequacy and integrity of measurement quality assurance programs

CASE STUDY: CALIBSENSORY PROJECT AIM OF THE PROJECT: TO ESTABLISH A CALIBRATION PROCEDURE FOR SENSORY TESTING OF PAPER AND BOARD FOOD CONTACT MATERIALS. 1st work objective: To develop procedures for the preparation of calibration samples: - for odour test by spiking odourless paper with a defined compound - for off-flavour test by spiking foods 2nd work objective: To establish a validated training procedure for sensory panels on how to use these calibration samples.

Stage 1: to create the formulas for calibration samples (Scores 0, 1, 2, 3 and 4) Odour test calibration: odour samples Off-flavour test calibration: Fatty food samples Off-flavour test calibration: Dry food Stage 2: Validation of panel calibration To determine the viability of the calibration samples by another laboratory, give feedback and agree on possible adjustments Stage 3: Intercomparison test To determine the feasibility of the calibration procedure in practise by an intercomparison test

creating formulas for calibration samples: matrix + spiking compound Which odorants / flavourings? Select appropriate spiking compounds to be used in the calibration samples and selection of the matrix Develop the spiking methods (and the chemical methods to determine the actual concentrations of the spiked compounds in the calibration samples) How do I spike the samples? Find the correct concentrations for scores (1-4) Which concentrations?

selection of appropriate matrix Kind of reference material: a neutral matrix with addition of additives. Two different media matrix odour test paper coffee filter paper off-flavour test fatty food coconut fat off-flavour test dry food icing sugar Conditions for selection of the provider for matrix: Quite neutral Routinely analysed in off-flavour context - Paper: for alimentary use, odourless, high quality, easily available. - Dry food and fatty food: food grade, free of off-flavours, high quality, easily available

selection of appropriate spiking compounds.and a solvent Additives: spiking compounds. matrix spiking compound odour test coffee filter paper Hexanal + triacetin off-flavour test coconut fat Benzaldehyde off-flavour test icing sugar Benzaldehyde + triacetin Conditions for selection of spiking compounds: - Flavour related to paper and board, safety (for alimentary use EU).

selection of the spiking method matrix spiking compound Spiking method odour test coffee filter paper Hexanal direct addition to paper off-flavour test coconut fat Benzaldehyde direct addition to fat off-flavour test icing sugar Benzaldehyde indirect contact / adsorption

Spiking method: odour Dilute hexanal with triacetin Preparation of the hexanal dilutions Fold the filter paper and put Cutting and folding the paper it into the flask Put paper inside the flask Spike paper with the hexanal solution close the flask Store Store flask the flasks for 3 for 3 hours Spike paper with hexanal solution and For each sample, each assessor has Each own assessor flasks have their own flasks Turn the flask once up and down Open the flask and immediately sniff

Spiking method: off-flavour, fatty food Preparation of benzaldehyde dilutions in melted coconut oil Pour spiked coconut oil onto holes of the mould Freeze test portions Drop down the test portions and serve them

Spiking method: off-flavour, dry food Arrange the containers with icing sugar Prepare in benzaldehyde circle solutions in triacetin Place the benzaldehyde solution in Arrange the centre icing sugar inside a dessicator Let benzaldehyde adsorb onto Place benzaldehyde solutions icing sugar for 24 hours and close dessicator Let benzaldehyde adsorb onto icing sugar for 24 hours Prior to sensory assessment, add Close mineral and remove water spiked and stir icing sugar test portions Replace the lid Before assessment of icing sugar add mineral water and stir

Validation of the spiking method...reproducibility of the spiking procedure Batch 1 Batch 2 Batch 3 Are samples similar? FUNDAMENTAL!!! Are samples similar? Homogeneity within batches Homogeneity between batches CHEMICAL ANALYSIS CHEMICAL ANALYSIS SENSORY ANALYSIS

Fresh samples Time 0 Time 1 Time 2 Time 3 Are samples similar? Stability of samples If samples are stable: Possibility of being prepared in one lab and send to others More practical: no need to assess immediately

CALIBRATION SAMPLES. HOMOGENEITY OF SAMPLES WITHIN BATCHES HOMOGENEITY OF SAMPLES BETWEEN BATCHES STABILITY FATTY FOOD VERY HOMOGENEOUS VERY HOMOGENEOUS VERY STABLE DURING 4 WEEKS AFTER PREPARATION DRY FOOD HOMOGENEOUS HOMOGENEOUS SHOULD BE ASSESSED WITHIN 2 HOURS AFTER PREPARATION ODOUR HOMOGENEOUS HOMOGENEOUS SHOULD BE ASSESSED IMMEDIATELY AFTER PREPARATION

Other spiking compounds... FATTY FOOD: Diacetyl: good results, although not as good as benzaldehyde Octanal: large variations in sensory thresholds between assessors ODOUR: Butyric acid: not full tested. Seemed to work Diacetyl: problems of adaptation, large variations between and within assessors

FINDING CONCENTRATIONS FOR CALIBRATION SAMPLES Concentrations for calibration samples for each medium were proposed by each partner / laboratory Concentrations of spiking compound in calibration samples are adjusted specifically to match a score of 0 to 4 on the recommended sensory scale. Score Descriptions Odour- Base paper µg Hexanal/ g base paper Off-flavour - Dry food µg Benzaldehyde/ g icing sugar (ppm) Off-flavour - Fatty food µg Benzaldehyde/ g coconut oil (ppm) 0 no perceptible 0 0 0 1 just perceptible 0.04 3.22 10 2 Weak 0.8 6.44 40 3 Clear 8 14.63 160 4 strong - 30.32 660 Assessment: scoring. Multiple comparison test. Deviation from reference (score 0: no off-odour or off-flavour) DIN scale has been used

FINDING CONCENTRATIONS FOR CALIBRATION SAMPLES Detection threshold oversized to the double app. DIN scale has been used 0 no perceptible off... 1 Off...just perceptible Identification threshold oversized to the double app. 2 3 4 Weak off... Clear off... strong off... Assessment: scoring. Multiple comparison test. Deviation from reference (score 0: no off-odour or off-flavour)

Creation of samples by one lab odour dry food Lab 1 Lab 2 fatty food Lab 3 Validation of samples by another lab odour dry food fatty food Lab 4 Lab 5 Lab 6 Validation of samples by many labs Inter-laboratory Odour trial Inter-laboratory dry food trial Inter-laboratory fatty food trial

Validation of calibration samples by another laboratory Objectives Establishment of a procedure on how to use the samples for panel calibration Feedback procedure and possible adjustment if necessary Procedure on how to use samples: Assessment without formal training (2 sessions) Training step (1 session) Assessment after training (2 sessions) Analysis of results. Comparison between results of 1 st lab and 2 nd. Odour test: only scores 0, 1, 2 and 3 are reliable and should be used. off-flavour test, for dry food: training had a positive effect. Off-flavour test, fatty food: training had an extremely positive effect.

INTER-COMPARISON TRIALS Final stage of the project: to determine feasibility of the calibration procedure in practise by means of inter-laboratory test One inter-laboratory for each kind of test samples: odour, dry and fatty food working objectives: - To evaluate the calibration samples (concentration and preparation instructions) - To validate the calibration procedures (including panel training) - To determine feasibility in practice of the overall procedures.

Basis of an inter-laboratory test schedule Test material Lab 1 Lab 2 Lab 3 Data 1 Data 2 Data 3 Analysis/comparison of results Result 1 Result 2 Result 3 Result Result Result

To participants: detailed instructions about materials and reagents needed, preparation of test materials and test portions, test procedure, sensory evaluation and scale, Trial odour fatty food dry food Nº of participants 15 18 8 Material provided Paper Pre-spiked coconut fat Icing sugar Order in time 2 nd (Jan-Feb 04) 1 st (Nov-Dec 03) 3 rd (Mar-Apr 04) Calibration samples 0, 1, 2 and 3 0, 1, 2, 3 and 4 0, 1, 2, 3 and 4

assessment of samples before training (2 rep) Panel calibration procedure: training session (1 rep) assessment of samples after training (2 rep) participants also complete: a checklist to record any deviation from instructions (immediately after the trial) a post-participation questionnaire (to help assess feasibility in practice)

REQUIREMENTS OF TEST MATERIAL General requirements for test material: Safety stability homogeneity Special requirements for test material: Similarity of test material to the type of products routinely analysed Sensory distances between test samples Sample preparation, conditions of testing

results of intercomparison trials 100 Before and after training 100 Before and after training 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0 Fatty food Odour Dry food Fatty food Odour Dry food Overall percentages of correct median values. Overall percentages of correct discrimination between sample pairs. - For all the trials % of correct median increased after training - Odour trial was the most difficult and the one with biggest improvement in discrimination between sample pairs

from post-participation questionnaire: "feasibility of the trials seems to decrease with increasing difficulty and preparation time labs have the feeling that the overall test procedure has helped raise the standard of the panel Fatty food: very feasible in practice (simple and robust spiking method) and samples stable Dry food: no very practical (time and cost) but it works too much dependence on very specific equipment further research? Odour: validity?: difficulties in finding differences between scores 0 and 1 no reference for score 4

CONCLUSIONS Have been these procedures effective in calibrating the panels? Panel performance has improve by training with the calibration samples but, will the participant panels produce more harmonized results when assessing a new and real set of samples??? Preparation of calibration samples Main output: calibration methods for odour and off-flavour Assessment before training Training Assessment after training Analysis of results

European standardisation: Paper and board intended for contact with foodstuffs Sensory analysis part 1: Odour & Part 2: Off-flavour will be revised in 2006 by the corresponding working group of the European Committee for standardization (CEN for pulp, paper and board) It will be proposed: to include the calibration methods eg. as Technical documents

CALIBSENSORY CONSORTIUM KCL, Paper Industry R & D Finland Coordination VTT Biotecnology, Food Industry R&D Finland panel calibration CTP (Centre technique du papier) Paper Industry R & D France Odour UNEW University of Newcastle Upon Tyne United Kingdom Statistics ainia centro tecnológico, Food Industry R & D Spain Dry food centro tecnológico CCFRA Campden & Chorleywood Food Research Association Group United Kingdom Intercomparison Iggesund Paperboard, Manufacturer of board Sweden Fatty food

CALIBSENSORY PROJECT SPECIFICATIONS Contract: G6RD-CT-2001-00514 Starting date: 1.9.2001 Duration: 36 months Project funded by the European Community under the Competitive and Sustainable Growth Programme (1998-2002)

Proficiency testing assessment of test material by panels, to compare lab results and check panel performance In CALIBSENSORY project creation of calibration material feasibility has been checked by means of inter-laboratory trials (panel performance before and after training with calibration samples)..

THANK YOU FOR YOUR ATTENTION!!!