Atomization. In Flame Emission

Similar documents
ATOMIC ABSORPTION SPECTROSCOPY (AAS) is an analytical technique that measures the concentrations of elements. It makes use of the absorption of light

Atomic Absorption Spectrophotometry. Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon

2101 Atomic Spectroscopy

ATOMIC SPECROSCOPY (AS)

FLAME PHOTOMETRY AIM INTRODUCTION

AN INTRODUCTION TO ATOMIC SPECTROSCOPY

Chemistry Instrumental Analysis Lecture 18. Chem 4631

3 - Atomic Absorption Spectroscopy

Optical Atomic Spectroscopy

high temp ( K) Chapter 20: Atomic Spectroscopy

Emission spectrum of H

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

Ch. 9 Atomic Absorption & Atomic Fluorescence Spectrometry

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

CH. 21 Atomic Spectroscopy

Atomic Emission Spectroscopy

INTRODUCTION TO OPTICAL ATOMIC SPECTROSCOPY (Chapter 8)

very high temperature for excitation not necessary generally no plasma/arc/spark AAS

Atomic Absorption Spectroscopy (AAS)

INTRODUCTION Atomic fluorescence spectroscopy ( AFS ) depends on the measurement of the emission ( fluorescence ) emitted from gasphase analyte atoms

Lecture 7: Atomic Spectroscopy

a. An emission line as close as possible to the analyte resonance line

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

A Spectrophotometric Analysis of Calcium in Cereal

PRINCIPLES OF AAS atomization flame furnace atomization absorption

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

Atomic absorption spectroscopy

II. Spectrophotometry (Chapters 17, 19, 20)

Chem 434 -Instrumental Analysis Hour Exam 1

Questions on Instrumental Methods of Analysis

Partial Energy Level Diagrams

UNIT I COLORIMETER AND SPECTROPHOTOMETERS PART A

HEAVY METALS IN LAKE NAKURU ATOMIC SPECTROSCOPY

25 Instruments for Optical Spectrometry

Chapter 9. Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques

Atomic Absorption Spectroscopy

Atomic Spectroscopy AA/ICP/ICPMS:

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Sub-category: Physics and Principles of Measurement Topic: Monitoring anesthetic gases and vapours Date: January 15-17, 2016 Language: English

2001 Spectrometers. Instrument Machinery. Movies from this presentation can be access at

Light Emission. Today s Topics. Excitation/De-Excitation 10/26/2008. Excitation Emission Spectra Incandescence

Light sources. Excited gas atoms are the primaty source of radiation in combustion and discharge lamps. lamps is not continuous!

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

Review: Light and Spectra. Absorption and Emission Lines

Atomic Absorption & Atomic Fluorescence Spectrometry

9/13/10. Each spectral line is characteristic of an individual energy transition

Lecture No. 4. i 0 TETA I RY:

Atomic Theory C &03

Spectroscopy Meditsiiniline keemia/medical chemistry LOKT Spectroscopy

Chem 321 Name Answer Key D. Miller

Complete the following. Clearly mark your answers. YOU MUST SHOW YOUR WORK TO RECEIVE CREDIT.

novaa 800 D Atomic Absorption Spectrometer

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

Chem 434 Instrumental Analysis Test 1

Spectrophotometry. Dr. Shareef SHAIK ASST. PROFESSOR Pharmacology

Introduction to Spectroscopic methods

3) In CE separation is based on what two properties of the solutes? (3 pts)

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

Chapters 3 & 4 in Tietz Fundamentals of Clinical Chemistry or Tietz Textbook of Clinical Chemistry.

MASTERING THE VCE 2014 UNIT 3 CHEMISTRY STUDENT SOLUTIONS

Unit 2 Exam: Atomic Structure

Absorption photometry

1. Cyclic voltammetry involves the measurement of a diffusion controlled at an electrode in which the is controlled. (4 points)

ANALYSIS OF ZINC IN HAIR USING FLAME ATOMIC ABSORPTION SPECTROSCOPY

Sample Copyright. Academic Group ATOMIC STRUCTURE 1. Topics covered in this chapter:

Atomic Absorption Spectrometer ZEEnit P series

Experiment 3 Electromagnetic Radiation and Atom Interaction

Ultraviolet-Visible and Infrared Spectrophotometry

Chemistry Instrumental Analysis Lecture 3. Chem 4631

Atomic Absorption Spectrometer (AAS) PerkinElmer Aanalyst 100

International Journal of Scientific & Engineering Research, Volume 8, Issue 1, January ISSN

Chapter 15 Molecular Luminescence Spectrometry

What are the six common sources of light?

Excimer Lasers Currently best UV laser sources Consist two atom types which repel each other eg nobel gas and halide or oxide which normally do not

Spectroscopy. Page 1 of 8 L.Pillay (2012)

SELİN CANSU ÖZTÜRK ŞEYMA ATAKUL SEZİN GÜNER

Analytical Spectroscopy Review

SPECTROSCOPY: A KEY TO ELEMENTAL IDENTITY

Higher -o-o-o- Past Paper questions o-o-o- 3.4 Spectra

COMPARISON OF ATOMIZERS

OXFORD NEW YORK PARIS FRANKFURT

Instrumental Analysis: Spectrophotometric Methods

Name the region of the electromagnetic radiation emitted by the laser. ...

Eximer Lasers UV laser sources Consist two atom types which repel each other eg nobel gas and halide or oxide When excited/ionized atoms attract

Pre-Lab Exercises Lab 2: Spectroscopy

Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry

Model Answer (Paper code: AR-7112) M. Sc. (Physics) IV Semester Paper I: Laser Physics and Spectroscopy

R O Y G B V. Spin States. Outer Shell Electrons. Molecular Rotations. Inner Shell Electrons. Molecular Vibrations. Nuclear Transitions

Chapter 8: An Introduction to Optical Atomic Spectrometry

UNIT 4 Part 2 Measurements of Environmental Air Pollution Parameters j

Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 23: GAS CHROMATOGRAPHY

Chemistry 311: Topic 2 - Atomic Spectroscopy Topic 2: Spectroscopy:

EMISSION SPECTROSCOPY

Atomic Spectroscopy. Absorption and Emission Spectra. Lodovico Lappetito. SpettroscopiaAtomica - 15/07/2015 Pag. 1

PRINCIPLE OF ICP- AES

Spectroscopy: Introduction. Required reading Chapter 18 (pages ) Chapter 20 (pages )

Two-electron systems

Transcription:

FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic by its monatomic particles in gaseous state in the flame.

Atomization - It is the conversion of molecules to their component atoms in gaseous state ; and it is carried out by introduction of the molecules solution in the flame in very fine droplet In Flame Emission -Atoms in gaseous state in the flame absorb thermal energy from the flame itself,some of the atoms get excited & as they return back to the ground state they emit radiation having energy equal to that absorbed. -The emission is proportional to the number of excited atoms, which is proportional to the total number of atoms in the flame i.e. the sample concentration

Flame Spectra The spectra of gaseous, atomic particles consist of well defined narrow discrete lines arising from electronic transition of outermost electrons. Since there is no bonds, atoms undergo electronic transition only, no vibrational or rotational transitions. The energy to which the atoms are subjected must be less than the ionization potential. The resonance wave - length (at which the most intense absorption and emission occur) is : 671 nm for lithium, 589 nm for sodium and 767 nm for potassium.

Energy Level Diagram:

The number of atoms of an element excited by the flame depends on : 1- Flame temperature 2- The energy difference between the excited and ground states. Accordingly -The number of excited atoms in the flame is considerably small, even in the case of alkaline metals which are easily excited. Sodium at 2500 k 0, 0.017% of the atoms are excited. Other metals the number of excited atoms is extremely small e.g. in case of zinc only 10-9 are excited. -Any increase of the flame temperature is accompanied by great increase in the number of excited atoms

< TD>

Limitation of Flame Emission Photometry 1-The number of excited atoms in flame is very small. It is the alkaline and alkaline earth metals that can be practically determined. 2-It needs perfect control of flame temperature. 3- Interference by other elements is not easy to be eliminated. 4-Heavy and transition metals, the number of absorption and emission lines is enormous and the spectra are complex.

INSTRUMENT FOR FLAME EMISSION 1-Flame atomizer. 2- Monochromator 3- Detector. 4- Readout meter.

< TD>

1-Flame Atomizer a-atomization of the sample. b- Source of thermal energy to excite the atoms. The atomizer is composed of : Nebulizer: Nebulizer, and burner is a device by which sample solution is divided into very fine droplets which are aspirated into fine spray or aerosol. As the oxidant flows it withdraws the sample from the capillary in very fine droplets Then mixed in the premixing chamber with the fuel gas. The fuel-oxidant-sample aerosol mixture passes to the burner producing the necessary heat for atomization and excitation r

< TD>

< TD>

In the burner The combustion of fuel occurs producing the necessary heat for atomization and excitation but not ionization. The temperature of the flame produced depends on fuel-oxidant ratio and kind.

In case of potassium, sodium, lithium and calcium, they are atomized and excited below 20000 k above 25000 k ionization occurs. The flame temperature must be : Regular :an increase by 10 0 c is accompanied by increase of 4% in the excited atoms. It must be sufficient to cause atomization only and not ionization. 2- Monochromator Either grating or interference filters which allow the resonance wavelength to pass to the detector.

ATOMIC ABSORPTION SPECTROSCOPY atoms in the vapor state are subjected to external source of radiation which produces one line or beam of monochromatic light with single wavelength. This wavelength is a resonance one for the atoms and that will be absorbed by them. All elements can be determined by this technique. INSTRUMENT FOR ATOMIC ABSORPTION 1- Source of radiation 2- Chopper 3- Atomizer 4-Monochromator 5- Detector 6- Read out meter

< TD>

1- Source of radiation ; Hollow cathode lamp: is a tube with a front quartz window contains an anode of tungsten and a cylindrical cathode, the material of which is the same element of the sample to be determined. The glass tube is filled with neon or argon at a pressure of 1 to 5 tore. When a low potential is applied between the two electrodes ionization of the gas occurs ions move rapidly to the cathode

< TD>

< TD>

< TD>

2-The chopper its function is to fluctuate the source output. It is a circular disc divided into four quarters two are mirrored and two are opened. The disc rotates at high constant speed, when the mirrored quarter in front of the lamp, it reflects the radiation the second moment the open in front of the lamp and the radiation passes to the sample being absorbed by it and reaches the detector in pulses. The detector converts the radiation to alternating current signal and amplified it. The radiation coming from the flame itself and from atoms excited by the flame will reach the detector continuously and converted to direct current signal which can be suppressed and eliminated. This process is known by modulation of the source output.

< TD>

3- Atomizer: a- Flame atomizer b- Flameless or non flame atomizer It is a graphite furnace heated electrically up to 6000 o C and contains a ribbon or boat in which one can inject the sample. Upon heating the furnace the sample is ashen, then atomized by action of heat. Advantages of non flame atomizer -The sample volume is small. - Unusual high sensitivity -Solid sample can be used directly. - No need for fuel -oxidant mixture. - No flame noise. - Heat distribution is uniform and temperature is steady.

4- Monochromator: Grating to eliminate other resonance lines from the source or other radiation from the flame or sample Schematic of an atomic-absorption experiment