Dispensette S NEW! Bottle-top Dispenser. The New Generation! n New discharge tube. n New valve system. n Faster priming. n Less force needed during

Similar documents
Dispensette S NEW! Bottle-top Dispenser. The New Generation! n New discharge tube. n New valve system. n Faster priming. n Less force needed during

Dispensette. Dispensette the right bottle-top dispenser for your application.

Dispensette. Dispensette the right bottle-top dispenser for your application.

Dispensette. The Standard in Bottletop Dispensing For Over 40 Years. D i s p e n s e r s

For any application the right Dispensette. Dispensette III Dispensette Organic Dispensette HF

Dispensette. Dispensette III Dispensette Organic Dispensette TA. Bottle-top Dispenser NEW!

Dispensette. The Standard in Bottletop Dispensing For Over 40 Years. Dispensers

Dispensette. The Standard in Bottletop Dispensing For Over 30 Years. D i s p e n s e r s

Dispensette. The Standard in Bottletop Dispensing For Over 40 Years. D i s p e n s e r s

Dispensette. The Standard in Bottletop Dispensing For Over 40 Years. Dispensers

Chemical resistance of Socorex dispensers

Chemical resistance of Socorex microdispensers

Appendix 5: table of chemical compatibility for tubing

500 SERIES CHEMICAL RESISTANCE GUIDE

Glove Selection Chart

Tube O Reactor. (Micro: Cat. # K, K, K) (Medi: Cat. # K, K, K)

PRODUCT DATA SHEET PDS A112_E. Metric thread M 1.5 pitch CEI EN CEI EN 50262

PRODUCT DATA SHEET PDS A88_E

The best material for original Eppendorf Tubes and Plates: Properties and chemical resistance of polypropylene

Safe Installation and Use of the NanoRam Immersion Probe

Chemical Resistance Guide for Flowchem EPN

Chemical Resistance Properties of Anko Tubing

PRODUCT DATA SHEET PDS A4_E. Metric thread M 1.5 pitch CEI EN CEI EN 50262

stance et Helper Eppendorf Pipet Helper Chemical Resistance

HSW NORM-JECT SYRINGES CHEMICAL RESISTANCE CHART

Spectra/Por. Float-A-Lyzer READY-TO-USE DIALYSIS DEVICES. Product Information & Operating Instructions

Peek Chemical Resistance

Liquid is assumed to be at saturated concentration in aqueous solution unless stated otherwise.

NaOH CH 3 CO 2 H C 2 H 5 OH. NaCl H 2 SO 4. Technical. Technical. Chemical Resistance Terms of Sale

Micro Float-A-Lyzer READY-TO-USE MICRODIALYSIS DEVICES. Product Information & Operating Instructions

Chemical Storage According to Compatibility

Chemical Resistance of PVC Products

Halar ECTFE chemical resistance chart

8 Materials, Corrosion Resistance Tables

Revised Permeation Values for DuPont Tychem SL

TAMMSFLEX SL / TAMMSFLEX NS

Chemical Polyurethane Polyethelyne PVC Nylon 11 Kynar

Safety Manual > Incompatible Chemicals Partial Listing

Solshield Hydrocarbon Gas Membrane Chemical Resistance Table

Fluid Compatibility Table

Media Compatibility Guide PVC Valves

CHEMICAL RESISTANCE DATA FOR POLYETHYLENES

FUNDERMAX GMBH TEST REPORT

Test Report For: FunderMax GmbH. MAX Resistance 2. SEFA , 2.1 Chemical/Stain Resistances

CHEMICAL RESISTANCE LIST

Watering Systems. Water and Chemical Reference Guide. Instruction # IM /06

A freely accessible HNS data base

Proper Storage of Chemicals in Laboratories

Principal Investigator: Department: Laboratory room #s: Updated/revised: Chemical Name Amount Physical state Location Hazard Class

Chemical Compatibility Guide Issue One

Technical data and operating instructions. Vivaspin 4. Vivaspin 4 10K device for in vitro diagnostic use

CHEMICAL RESISTANCE TABLE

Chemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder

N6,6 Posidyne Membranes

Sizes 48" x 96" (1.22m x 2.44m) Custom sheet sizes available upon request

Swell Sheet Chemical Resistance Guide

Chemical Resistance Chart for Plastic Labware Please see page 428 for table notes and guide to abbreviations.

stance 4 Repeater M4 Register your instrument! Multipette M4 Repeater M4 Chemical Resistance

CHEMICAL RESISTANCE CHART

Swell Sheet Chemical Resistance Guide

The Right Choice Merck Solvents for Analysis. Highest quality wide range of applications

APPENDIX C CHEMICALS USED IN CLANDESTINE DRUG LABS

Chemical Resistance. Suitable Suitability depends on operating conditions Unsuitable. Topchem 2000/2003. Milam PSS / Mica. Hygrade LS / PTFE.

WESTERN CONNECTICUT STATE UNIVERSITY CHEMICAL STORAGE AND COMPATIBILITY GUIDELINES PROCEDURE S-118

High Purity Chromasolv Solvents

CHEMICAL RESISTANCE LIST

Choosing the Right KLEENGUARD* Chemical Resistant Glove for the Job

Headspace Technology for GC and GC/MS: Features, benefits & applications

Chemical Storage Guidelines

MasterSeal M 452. Water based epoxy bituminous chemically resistant waterproofing membrane.

Combustible Gas Catalytic Bead (0-100 %LEL) Part No FM Performance Certified 1,4 FM Performance Certified 1

Chemical Resistance Tables

Ferdowsi University of Mashhad

SOLUZIONI PER L ENERGIA TERMICA THERMAL ENERGY SOLUTIONS

Spectroscopy in Inorganic Chemistry. Electronic Absorption Spectroscopy

GL Chromatodisc. Usage Type Description. GL Chromatodisc Type A GL Chromatodisc Type P GL Chromatodisc Type N 13AI

Color Availability Clear Standard colors stocked (thin gauge only) Custom colors available by special order.

Gloves: choice and use

CHEMICAL RESISTANCE LIST

gerflor.com.au Stain chemicals

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

INCOMPATIBILITY BETWEEN CHEMICALS

COPPER SHEATHED CABLE

FR CLOTHIN G FOR L ABORATORIES

CH CH. Thermo Scientific Labware Chemical Resistance Table. Effects of Chemicals. on Plastics

PREVENTING HAZARDOUS WASTE FINES

Materials of Construction and Chemical Compatibility for Sensing and Control Products

DRUM PUMP CHEMICAL RESISTANCE GUIDE & APPLICATION WORKSHEET

catalogue of thermoplastic Gears

Molded/Machined Both Both Machined Machined Both Dielectric Strength V/mil D ,000

Buy 2 Get 1 FREE on Acros Organics

HAZARDOUS MATERIALS SURVEY. Note: List ALL virgin stock materials in current and projected inventories LAB NAME: PI: ADDRESS:

FR CLOTHIN G FOR L ABORATORIES TECHNICAL BRIEF

PRODUCT DATA SHEET PDS A5_E

Zirconium in Organic Applications

Chemical Resistance Chart for Tamco Tanks

Target Compound Results Summary

OREGON Environmental Laboratory Accreditation Program ORELAP Fields of Accreditation ALS Environmental - Simi Valley

Eppendorf UVette. Instructions for use

Transcription:

The New Generation! Dispensette S Bottle-top Dispenser F I R S T C L A S S B R A N D Innovative ideas with trusted technology the new bottle-top dispenser. n New discharge tube with or without recirculation valve n New valve system no sealing rings necessary n Faster priming due to improved flow technology n Less force needed during dispensing especially for instruments with large volumes n Volume selection with interior scalloped track for analog devices, enhances setting reproducibility n New 1 size digital and analog

A Closer Look... The bottle-top dispenser has all the features that make dispensing safer and convenient. Innovative ideas trusted technology. Easy Calibration Technique Calibration and adjustments according to ISO 9001 and GLP are done within seconds. Organic Digital Calibration mechanism Discharge valve with safety ball closes when discharge tube is not mounted Discharge tube without Large viewport Analog-adjustable Volume selection using interior scalloped track Discharge tube with Hinged screw cap doesn't get in the way when dispensing 360 rotating valve block with GL 45 thread Filling valve olive-shaped for firmer attachment of the filling tube Recirculation tube for discharge tubes with Telescoping filling tube

The right choice for a wide variety of applications Organic Organic solvents Acids Dispensette S Organic Areas of application Bases Saline solutions supports a very wide range of applications for the dispensing of aggressive reagents directly from the supply bottle: such as concentrated bases and acids like H 3 PO 4, H 2 SO 4 (with certain exceptions such as HCl, HNO 3, HF, etc.), saline solutions, and a variety of organic solvents. Materials in contact with media Borosilicate glass, Al 2 O 3 - ceramic, platinum-iridium, ETFE, FEP, PFA, PTFE and PP Organic is ideal for dispensing organic solvents: such as chlorinated and fluorinated hydrocarbons like trichlorotrifluoroethane and dichloromethane, or acids like concentrated HCl and HNO 3 (except for HF), as well as for trifluoroacetic acid (TFA), tetrahydrofurane (THF), and peroxides. Borosilicate glass, Al 2 O 3 - ceramic, tantalum, ETFE, FEP, PFA, PTFE and PP For dispensing hydrofluoric acid (HF), we recommend the use of the Trace Analysis bottle-top dispenser with platinum-iridium valve spring! Please find further product information at www.brand.de Operating limits Vapor pressure max. 600 mbar viscosity max. 500 mm 2 /s temperature max. 40 C density max. 2.2 g/cm 3 Vapor pressure max. 600 mbar viscosity max. 500 mm 2 /s temperature max. 40 C density max. 2.2 g/cm 3

Easy Handling Easier dispensing and faster priming In the "floating piston" design, the pistons and cylinders are fitted individually in such a way that the gap between them is just a few micrometers wide. This gap is filled by the fluid being dispensed, forming a zero-wear sealing system with outstanding sliding properties. Optimized flow channels make dispensing and priming even easier particularly in instruments with large volumes. Simple to mount The new discharge tube is easy to fasten and is available with or without a. Positive volume setting In analog dispensers, volume setting is quick, secure and repeatable due to the interior scalloped track. Out of the way So it doesn't impede you while dispensing, the screw cap pivots entirely away from the working area.

Trusted technology Designed without seals All valves work without any additional sealing rings. That makes cleaning and preparation for autoclaving easier. Fast calibration With Easy Calibration technique, you can calibrate quickly and easily in the laboratory in just a few steps. BRAND also offers a factory calibration service. Autoclavable at 121 C Easy to calibrate and adjust in order to comply with ISO 9001 and GLP guidelines. A positive indicator automatically indicates adjustment from factory settings. Easy to dismantle for cleaning Replaceable filling and discharge valve with safety ball The valve block can be rotated 360 so that the bottle label always faces the user for safety Telescoping filling tube adjusts to different bottle sizes The 45 mm standard thread plus the included adapters fit common lab bottles An extensive line of accessories makes possible special dispensing tasks like sterile applications or dispensing from large containers DE-M marking* * legally replaces since January 1, 2015 Serial dispensing The flexible discharge tube facilitates serial dispensing. It permits fast and precise dispensing even into narrow test tubes. Dispensing sterile fluids Organic and are completely autoclavable at 121 C. A connectable microfilter filters the air entering the bottle. Dispensing sensitive reagents The drying tube protects sensitive reagents against humidity or CO 2. You can find more information about our dispenser accessories at www.brand.de

Dispenser Selection Chart Reagent Acetaldehyde + + Acetic acid (glacial), 100% + + Acetic acid, 96% + + Acetic anhydride + Acetone + + Acetonitrile + + Acetophenone + Acetyl chloride + Acetylacetone + + Acrylic acid + + Acrylonitrile + + Adipic acid + Allyl alcohol + + Aluminium chloride + Amino acids + Ammonia, 20% + + Ammonia, 20-30% + Ammonium chloride + Ammonium fluoride + Ammonium sulfate + n-amyl acetate + + Amyl alcohol (Pentanol) + + Amyl chloride (Chloropentane) + Aniline + + Barium chloride + Benzaldehyde + + Benzene (Benzol) + + Benzine (Petroleum benzin), bp 70-180 C + Benzoyl chloride + + Benzyl alcohol + + Benzylamine + + Benzylchloride + + Boric acid, 10% + + Bromobenzene + + Bromonaphthalene + + Butanediol + + 1-Butanol + + n-butyl acetate + + Butyl methyl ether + + Butylamine + + Butyric acid + + Calcium carbonate + Calcium chloride + Calcium hydroxide + Calcium hypochlorite + Carbon tetrachloride + Chloro naphthalene + + Chloroacetaldehyde, 45% + + Chloroacetic acid + + Chloroacetone + + Chlorobenzene + + Chlorobutane + + Chloroform + Chlorosulfonic acid + Chromic acid, 50% + + Chromosulfuric acid + Copper sulfate + Cresol + Cumene (Isopropyl benzene) + + Organic Reagent Cyclohexane + Cyclohexanone + + Cyclopentane + Decane + + 1-Decanol + + Dibenzyl ether + + Dichloroacetic acid + Dichlorobenzene + + Dichloroethane + Dichloroethylene + Dichloromethane + Diesel oil (Heating oil), bp 250-350 C + Diethanolamine + + Diethyl ether + Diethylamine + + 1.2 Diethylbenzene + + Diethylene glycol + + Dimethyl sulfoxide (DMSO) + + Dimethylaniline + Dimethylformamide (DMF) + + 1.4 Dioxane + Diphenyl ether + + Essential oil + Ethanol + + Ethanolamine + + Ethyl acetate + + Ethylbenzene + Ethylene chloride + Fluoroacetic acid + Formaldehyde, 40% + Formamide + + Formic acid, 100% + Glycerol + + Glycol (Ethylene glycol) + + Glycolic acid, 50% + Heating oil (Diesel oil), bp 250-350 C + Heptane + Hexane + Hexanoic acid + + Hexanol + + Hydriodic acid, 57% ** + + Hydrobromic acid + Hydrochloric acid, 20% + + Hydrochloric acid, 20-37% ** + Hydrogen peroxide, 35% + Isoamyl alcohol + + Isobutanol + + Isooctane + Isopropanol (2-Propanol) + + Isopropyl ether + + Lactic acid + Methanol + + Methoxybenzene + + Methyl benzoate + + Methyl butyl ether + + Methyl ethyl ketone + + Methyl formate + + Methyl propyl ketone + + Organic Reagent Methylene chloride + Mineral oil (Engine oil) + + Monochloroacetic acid + + Nitric acid, 30% + + Nitric acid, 30-70% * / ** + Nitrobenzene + + Oleic acid + + Oxalic acid + n-pentane + Peracetic acid + Perchloric acid + + Perchloroethylene + Petroleum, bp 180-220 C + Petroleum ether, bp 40-70 C + Phenol + + Phenylethanol + + Phenylhydrazine + + Phosphoric acid, 85% + + Phosphoric acid, 85% + Sulfuric acid, 98%, 1:1 + + Piperidine + + Potassium chloride + Potassium dichromate + Potassium hydroxide + Potassium permanganate + Propionic acid + + Propylene glycol (Propanediol) + + Pyridine + + Pyruvic acid + + Salicylaldehyde + + Scintilation fluid + + Silver acetate + Silver nitrate + Sodium acetate + Sodium chloride + Sodium dichromate + Sodium fluoride + Sodium hydroxide, 30% + Sodium hypochlorite + Sulfuric acid, 98% + + Tartaric acid + Tetrachloroethylene + Tetrahydrofuran (THF) * / ** + Tetramethylammonium hydroxide + Toluene + Trichloroacetic acid + Trichlorobenzene + Trichloroethane + Trichloroethylene + Trichlorotrifluoro ethane + Triethanolamine + + Triethylene glycol + + Trifluoro ethane + Trifluoroacetic acid (TFA) + Turpentine + Urea + Xylene + Zinc chloride, 10% + Zinc sulfate, 10% + Organic The above recommendations reflect testing completed prior to publication. Always follow instructions in the operating manual of the instrument as well as the reagent manufacturer s specifications. In addition to these chemicals, a variety of organic and inorganic saline solutions (e.g., biological buffers), biological detergents and media for cell culture can be dispensed. Should you require information on chemicals not listed, please feel free to contact BRAND. Status as of: 0605/13 * use ETFE/PTFE bottle adapter ** use PTFE seal for valve block Note! For dispensing HF, we recommend the use of the Trace Analysis bottle-top dispenser with platinum-iridium valve spring.

Ordering Information Items supplied: / Organic bottle-top dispenser, DE-M marking, performance certificate, telescoping filling tube, recirculation tube (optional), mounting tool and adapters of polypropylene: Nominal volume Adapter for bottle thread Filling tube length 1, 2, 5, 10 GL 24-25, GL 28/S 28, GL 32-33, GL 38, S 40 125-240 mm 25, 50, 100 GL 32-33, GL 38, S 40 170-330 mm Capacity Subdivision A* ± % µl CV* % µl without with n, Digital 0.1-1 0.005 0.6 6 0.2 2 613-5289 613-5290 0.2-2 0.01 0.5 10 0.1 2 613-5291 613-5292 0.5-5 0.02 0.5 25 0.1 5 613-5293 613-5294 1-10 0.05 0.5 50 0.1 10 613-5295 613-5296 2.5-25 0.1 0.5 125 0.1 25 613-5297 613-5298 5-50 0.2 0.5 250 0.1 50 613-5299 613-5329 n, Analog-adjustable 0.1-1 0.02 0.6 6 0.2 2 613-5225 613-5226 0.2-2 0.05 0.5 10 0.1 2 613-5227 613-5228 0.5-5 0.1 0.5 25 0.1 5 613-5229 613-5230 1-10 0.2 0.5 50 0.1 10 613-5231 613-5233 2.5-25 0.5 0.5 125 0.1 25 613-5234 613-5235 5-50 1.0 0.5 250 0.1 50 613-5236 613-5237 10-100 1.0 0.5 500 0.1 100 613-5238 613-5239 n, Fixed-volume 1 0.6 6 0.2 2 613-5240 613-5241 2 0.5 10 0.1 2 613-5242 613-5243 5 0.5 25 0.1 5 613-5244 613-5245 10 0.5 50 0.1 10 613-5246 613-5247 Special fixed volumes: 0.5-100 (please state when ordering) 613-5249 613-5288 Organic Capacity Subdivision A* ± % µl CV* % µl without with n Organic, Digital 0.5-5 0.02 0.5 25 0.1 5 613-5346 613-5347 1-10 0.05 0.5 50 0.1 10 613-5348 613-5349 2.5-25 0.1 0.5 125 0.1 25 613-5350 613-5351 5-50 0.2 0.5 250 0.1 50 613-5352 613-5353 n Organic, Analog-adjustable 0.5-5 0.1 0.5 25 0.1 5 613-5330 613-5331 1-10 0.2 0.5 50 0.1 10 613-5332 613-5333 2.5-25 0.5 0.5 125 0.1 25 613-5334 613-5335 5-50 1.0 0.5 250 0.1 50 613-5336 613-5337 10-100 1.0 0.5 500 0.1 100 613-5338 613-5339 n Organic, Fixed-volume 5 0.5 25 0.1 5 613-5340 613-5341 10 0.5 50 0.1 10 613-5342 613-5343 Special fixed volumes: 2-100 (please state when ordering) 613-5344 613-5345 * Calibrated to deliver (TD, Ex). Error limits according to the nominal capacity (= maximum volume) indicated on the instrument, obtained with instrument and distilled water at equilibrium with ambient temperature at 20 C, and with smooth, steady operation. The error limits are well within the limits of DIN EN ISO 8655-5. DE-M marking. A = Accuracy, CV = Coefficient of variation Note! For trace analysis and dispensing HF, we recommend the use of the Trace Analysis bottle-top dispenser.

Accessories Spare Parts Discharge tubes With and without. Screw cap PP. Description Nominal volume Shape Length mm without with 1, 2, 5, 10 fine tip 105 613-5200 613-5212 5, 10 standard 105 613-5201 613-5213 25, 50, 100 fine tip 135 613-5202 613-5214 25, 50, 100 standard 135 613-5203 613-5215 Organic 5, 10 standard 105 613-5205 613-5216 25, 50, 100 fine tip 135 613-5207 613-5217 25, 50, 100 standard 135 613-5208 613-5218 Telescoping filling tubes For and Organic. FEP. Adjusts to various bottle heights. Flexible discharge tube with * For and Organic. PTFE, coiled, length approx. 800 mm, with safety handle. Nominal volume Outer Ø mm Length mm Nominal volume Discharge tube Outer Ø mm Inner Ø mm 1, 2, 5, 10 6 70-140 613-5194 125-240 613-5195 195-350 613-5196 250-480 613-5197 25, 50, 100 7.6 170-330 613-5198 250-480 613-5199 2, 5, 10 3 2 613-5221 25, 50, 100 4.5 3 613-5195 * not suitable for HF Sealing ring for valve block PTFE. For highly volatile media. 613-3854 Bottle stand PP. Full plastic construction. Support rod 325 mm, base plate 220 x 160 mm, weight 1130 g. 613-1763 Drying tube incl. PTFEsealing ring Without drying agent. 613-3444 Additional accessories can be found at www.brand.de GO TO VWR.COM FOR THE LATEST NEWS, SPECIAL OFFERS AND DETAILS OF YOUR LOCAL VWR DISTRIBUTOR 1015 BRAND and Dispensette are registered trademarks of BRAND GMBH + CO KG, Germany.