ANALYSIS OF TURBULENT FLOW IN THE IMPELLER OF A CHEMICAL PUMP

Similar documents
Application of two turbulence models for computation of cavitating flows in a centrifugal pump

Numerical investigation of solid-liquid two phase flow in a non-clogging centrifugal pump at offdesign

1917. Numerical simulation and experimental research of flow-induced noise for centrifugal pumps

Numerical calculation for cavitation flow of inducer

Effect of modification to tongue and basic circle diameter on vibration in a double-suction centrifugal pump

Internal Flow Measurements of Turbomachinery using PIV

Research on energy conversion mechanism of a screw centrifugal pump under the water

PIV measurement and study on turbulence generator flow field of medium consistency pump

The effect of rotational speed variation on the static pressure in the centrifugal pump (part 1)

STUDY ON TIP LEAKAGE VORTEX IN AN AXIAL FLOW PUMP BASED ON MODIFIED SHEAR STRESS TRANSPORT k-ω TURBULENCE MODEL

Open Access Experimental Research and Analysis of Vortex Excited Vibration Suppression of Spiral Stripe Strake

Effect of Reflux Hole on the Transient Flow Characteristics of the Self-Priming Sewage Centrifugal Pump

PIV INVESTIGATION OF THE INTERNAL FLOW STRUCTURE IN A CENTRIFUGAL PUMP IMPELLER

Flow analysis in centrifugal compressor vaneless diffusers

A Comparative Study of Low-Specific Speed Centrifugal Pump Design Methods

chinaxiv: v1

FLOW CHARACTERISTICS IN A VOLUTE-TYPE CENTRIFUGAL PUMP USING LARGE EDDY SIMULATION

Numerical Simulation Analysis of Ultrafine Powder Centrifugal Classifier Bizhong XIA 1, a, Yiwei CHEN 1, b, Bo CHEN 2

Fluid structure interaction dynamic analysis of a mixed-flow waterjet pump

DESIGN AND CFD ANALYSIS OF A CENTRIFUGAL PUMP

CFD Simulation in Helical Coiled Tubing

Correction and Experimental Verification of Velocity Circulation in a Double-blade Pump Impeller Outlet

Flow behaviour analysis of reversible pumpturbine in "S" characteristic operating zone

ON THE ONSET AND DEVELOPMENT OF ROTATING STALL WITHIN A VANED DIFFUSER OF A CENTRIFUGAL PUMP

Analysis of flow characteristics of a cam rotor pump

CHAPTER 7 NUMERICAL MODELLING OF A SPIRAL HEAT EXCHANGER USING CFD TECHNIQUE

Colloquium FLUID DYNAMICS 2013 Institute of Thermomechanics AS CR, v.v.i., Prague, October 23-25, 2013 p.1

Design optimization of a centrifugal pump impeller and volute using computational fluid dynamics

SIMULTANEOUS VELOCITY AND CONCENTRATION MEASUREMENTS OF A TURBULENT JET MIXING FLOW

Active Control of Separated Cascade Flow

Study on the Performance of a Sirocco Fan (Flow Around the Runner Blade)

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

Numerical Study of Pressure and Velocity Distribution Analysis of Centrifugal Pump

FLOW CHARACTERIZATION WITHIN A SPHERE-PACKED BED USING PIV MEASUREMENT

PIV Measurements in the Impeller and the Vaneless Diffuser of a Radial Flow Pump in Design and Off-Design Operating Conditions

Flow field distribution of liquid film of water lubricated bearing-rotor coupling systems

COMPUTATIONAL FLOW ANALYSIS THROUGH A DOUBLE-SUCTION IMPELLER OF A CENTRIFUGAL PUMP

MODELLING PARTICLE DEPOSITION ON GAS TURBINE BLADE SURFACES

FLUID CHARACTERISTICS OF ROTARY WING HEAT METER WITH SINGLE-CHANNEL *

Efficiency improvement and evaluation of a centrifugal pump with vaned diffuser

Experimental Investigation on Unsteady Pressure Pulsation in a Centrifugal Pump With Special Slope Volute

The Fluid Flow in the T-Junction. The Comparison of the Numerical Modeling and Piv Measurement

Experimental Study on the Non-reacting Flowfield of a Low Swirl Burner

Experimental Investigation on the Acoustic Scattering Matrix for a Centrifugal Pump

Article Energy Performance and Flow Patterns of a Mixed- Flow Pump with Different Tip Clearance Sizes

GUIDE VANES EMBEDDED VISUALIZATION TECHNIQUE FOR INVESTIGATING FRANCIS RUNNER INTER-BLADE VORTICES AT DEEP PART LOAD OPERATION

Simultaneous Velocity and Concentration Measurements of a Turbulent Jet Mixing Flow

CFD SIMULATIONS OF SINGLE AND TWO-PHASE MIXING PROESSES IN STIRRED TANK REACTORS

Turbulence Laboratory

THE EFFECT OF SAMPLE SIZE, TURBULENCE INTENSITY AND THE VELOCITY FIELD ON THE EXPERIMENTAL ACCURACY OF ENSEMBLE AVERAGED PIV MEASUREMENTS

THERMAL ANALYSIS OF SECOND STAGE GAS TURBINE ROTOR BLADE

A SIMPLE ACOUSTIC MODEL TO SIMULATE THE BLADE-PASSING FREQUENCY SOUND PRESSURE GENERATED IN THE VOLUTE OF CENTRIFUGAL PUMPS

NUMERICAL INVESTIGATION OF PERFORMANCE OF KAPLAN TURBINE WITH DRAFT TUBE

PIV Measurements to Study the Effect of the Reynolds Number on the Hydrodynamic Structure in a Baffled. Vessel Stirred by a Rushton Turbine

Effect of Suction Pressure on Hydraulic Parameters of Booster Pumping Station

NUMERICAL SIMULATION OF THREE DIMENSIONAL GAS-PARTICLE FLOW IN A SPIRAL CYCLONE

Numerical and Experimental Investigation of the Flow in a Centrifugal Pump Stage

Computation on Turbulent Dilute Liquid-Particale. Flows through a Centrifugal Impeller*

Experimental and numerical analysis of eight different volutes with the same impeller in a squirrel-cage fan

LIQUID FILM THICKNESS OF OSCILLATING FLOW IN A MICRO TUBE

RESEARCH ON THE SELF-INDUCED SLOSHING PHENOMENA IN A RECTANGULAR TANK

Visualization of Traveling Vortices in the Boundary Layer on a Rotating Disk under Orbital Motion

Numerical Investigation of Fluid Flow Mechanism in the Back Shroud Cavity of a Centrifugal Pump

93. Study on the vibration characteristics of structural of hydrocyclone based on fluid structure interaction

Analysis of Heat Transfer in Pipe with Twisted Tape Inserts

Effect of impeller reflux balance holes on pressure and axial force of centrifugal pump

FLOW PATTERN STUDY OF A CENTRIFUGAL PUMP USING CFD METHODS CONCENTRATING ON VOLUTE TONGUE ROLE

Interaction of impeller and guide vane in a seriesdesigned

1. Starting of a project and entering of basic initial data.

INVESTIGATION OF SWIRLING FLOW IN DIFFUSERS INSTALLED AT THE EXIT OF AN AXIAL-FLOW PUMP

Analysis of High Speed Spindle with a Double Helical Cooling Channel R.Sathiya Moorthy, V. Prabhu Raja, R.Lakshmipathi

Vortex cavitation and oscillation in a doublesuction

Impeller and volute design and optimization of the centrifugal pump with low specific speed in order to extract performance curves

CDF CALCULATION OF RADIAL FAN STAGE WITH VARIABLE LENGTH OF SEMI BLADES SVOČ FST 2012

CFD ANALYSIS OF TURBULENCE EFFECT ON REACTION IN STIRRED TANK REACTORS

Investigation of hydraulic performance in an axial-flow blood pump with different guide vane outlet angle

Performance characteristics of turbo blower in a refuse collecting system according to operation conditions

Wall treatments and wall functions

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

NUMERICAL AND EXPERIMENTAL INVESTIGATIONS OF AIR FLOW AND TEMPERATURE PATTERNS OF A LOW VELOCITY DIFFUSER

Dynamic Simulation in Guide Vane Opening Process of a Pump-Turbine in Pump Mode

ON THE ONSET AND DEVELOPMENT OF ROTATING STALL WITHIN A VANED DIFFUSER OF A CENTRIFUGAL PUMP

Performance Investigation of High Pressure Ratio Centrifugal Compressor using CFD

Cavitating Pump Performance

FEDSM99 S-291 AXIAL ROTOR OSCILLATIONS IN CRYOGENIC FLUID MACHINERY

A NUMERICAL ANALYSIS OF COMBUSTION PROCESS IN AN AXISYMMETRIC COMBUSTION CHAMBER

Optimizing Centrifugal Pump Performance by Different Blade Configuration Patterns

Visualization of Distribution of Shear Stress due to Water Vortex Flow with SSLCC

Steady and unsteady flow inside a centrifugal pump for two different impellers

Laminar flow heat transfer studies in a twisted square duct for constant wall heat flux boundary condition

Experiments on the perturbation of a channel flow by a triangular ripple

PARTICLE TRACKING VELOCIMETRY (PTV) MEASUREMENT OF ABRASIVE MICROPARTICLE IMPACT SPEED AND ANGLE IN BOTH AIR-SAND AND SLURRY EROSION TESTERS

ASSESSMENT OF DESIGN METHODOLOGY AND THREE DIMENSIONAL NUMERICAL (CFD) ANALYSIS OF CENTRIFUGAL BLOWER

Numerical analysis of fluid flow and heat transfer in 2D sinusoidal wavy channel

Multiphase Science and Technology, Vol. 16, Nos. 1-4, pp. 1-20, 2005

Analysis of Rotor-Stator Interaction in Turbine Mode of a Pump-Turbine Model

NUMERIC SIMULATION OF ULTRA-HIGH PRESSURE ROTARY ATOMIZING WATERJET FLOW FIELD

NUMERICAL SIMULATION AND STRUCTURE IMPROVEMENT ON CYCLONE PURIFIER FOR FRESH AIR TREATING

PARTICLE IMAGE VELOCIMETRY MEASUREMENTS IN AN AERATED STIRRED TANK

Entropic Evaluation of Dean Flow Micromixers

Transcription:

Journal of Engineering Science and Technology Vol. 2, No. 3 (2007) 218-225 School of Engineering, Taylor s University College ANALYSIS OF TURBULENT FLOW IN THE IMPELLER OF A CHEMICAL PUMP MIN-GUAN YANG, DONG LIU*, XIANG DONG School of Energy and Power Engineering, JiangSu University, Zhenjiang, 212013, CHINA. *Corresponding Author: liudong@ujs.edu.cn Abstract To study the phenomena of two-phase flow with salt crystallising in the chemical pump, the 3-D turbulent flow in the impeller of chemical pump was simulated at the condition of rinsing. The internal flow between the impellers of 1H65 chemical pump is investigated. Based on the Reynolds-averaging N-S equations and the standard k-ε two equations turbulent model, the simulations of turbulent flow between the impellers are performed using the flow computing software Fluent under different operating conditions. The calculation results are compared with the experimental data by particle image velocimetery (PIV). Based on the analysis of the calculated results of velocity and pressure profiles in the chemical pump and experimentally observed phenomenon of flow impact, secondary flow and recirculation, some design improvements are proposed, which give suggestions on the optimal design and internal two-phase flow study of the chemical pump. Keywords: Chemical pump Impeller, Numerical simulation, PIV. 1. Introduction The basic science problem of two-phase flow with salt crystallising in the centrifugal pump has always been a puzzle in the area of science and technology. Salt crystallising in the centrifugal pump is very common in paper making pulp and petrochemical manufacture. Because of the influence of viscosity and twophase fluid with salt crystallizing, the flow in the impeller of centrifugal pump is very complex. Many researchers are always paying attention to the study of interior flow in centrifugal pump. The probe we used before can only measure one point. As the development of laser measurement technology, it is agreed that using PIV to study the interior flow of pump. There are many examples of application now. 218

Analysis of Turbulent Flow in the Impeller of A Chemical Pump 219 Nomenclatures b 2 D 2 H n n s Q Q opt t u x u y X Y z Outlet breadth Outer diameter Pump head Rotational speed Specific speed Pump flux Design flux of the pump Pulse duration interval Velocity in X direction Velocity in Y direction Particle bit shift in the X direction Particle bit shift in the Y direction Number of vanes To reveal the real flow in impeller, the 3D turbulent flow in the impeller of centrifugal pump was studied at the condition of rinsing. Using simulation to conclude the distribution of velocity and pressure, and PIV to prove the interior flow in the impeller. The CFD software FLUENT is used. Based on the Reynolds-averaging N-S equations and standard k-ε two equations turbulent model, the internal flow in the impeller with the work condition of 0.8 Q opt, Q opt, 1.2 Q opt are calculated. Simultaneously the result of calculation is compared with PIV measurement, further understanding is obtained about the internal flow field in the impeller of chemical pump, and moreover, the research can provide reference for the twophase flow research in the impeller. 2. The Numerical Simulation In The Impeller 2.1 Parameters of the impeller The parameters of 3-D turbulent flow numerical simulated inside the impeller of the chemical pump are given in Table 1. The operating medium is water. 2.2 Calculated area and calculated grid Nonconformal grids are adopted in this work. And during the process of plotting grids, inlet, outlet and wall are defined; the plotted grid result and the calculated area can be seen in Fig.1.

220 Dong Liu & Min-guan Yang Table 1. Test Parameters. Parameter Value Impeller outer diameter (D 2 ) 132 mm Outlet breadth (b 2 ) 12 mm Number of vanes (z) 6 Design flux (Q opt ) 25 m 3.h -1 Design head (H) 20 m Rotating speed (n) 2890 rpm Specific speed (n s ) 93 Figure 1 Diagrammatic Sketch of 3-D Model and Calculated Grid. 3 Experimental System and Principle 3.1 Experimental system Figure 2 shows the experimental system. In order to meet the requirement of PIV system, we take the optimal design of chemical pump. The design flux of pump is 25 m 3.h -1, design head is 20m, and the rotating speed is 2890 rpm. Both impeller and spiral casing back cover are made of glass, so the CCD camera could light the whole field in the impeller. A rectangle window was opened at the flank of spiral casing. The PIV system consists of a two-pulsed Nd-Yag laser, a CCD camera, a synchronizer and a data analysis system. The Laser with wavelength of 532nm has a frequency of 15 Hz. The output power of the laser is 120mJ/puls, which is sufficiently high for the experiment. The CCD camera was used to obtain digital images with 1248 1024 pixels, and can capture 3.75 pictures in one second. The particles used in these experiments are hollow glass particles with diameters of 8-10 micron. The shaft encoder and frequency divider is used to deal with rotating flow. Shaft encode is fixed up on axes of motor. With every rotating of encoder, shaft encoder transmits 500 pulse signals which were divided by frequency divider to meet the speed collection of CCD. Figure 3 is the circuit of frequency divider.

Analysis of Turbulent Flow in the Impeller of A Chemical Pump 221 Fig. 2. Schematic of the Experimental System. Fig.3. Circuit of Frequency Divider. 3.2 Basic principles of PIV The basic principle of PIV is to measure the displacement of particles within a pulse duration interval t, in two directions, X and Y, and then infer the velocity of the particle as follow: u x = X/ t (1) u y = Y/ t (2) The principle is show in Fig 4. Due to the features of the tracer particles, particle s velocity is the same as the velocity of flow motion. The displacement of particles should be as small as possible to let x/ t close to particle s velocity. That s to say, within the time of t, the tracer of particles are almost lines and particle s velocity in the tracer is almost invariableness, which should be satisfied with a proper time of t.

222 Dong Liu & Min-guan Yang Fig. 4 Basic Principle of PIV. 4. Analysis of The Result of Calculations and Experiments 4.1 Relative speed distribution Figure 5 shows the relative speed distribution for the work condition of 0.8Q opt, Q opt, 1.2 Q opt. It shows that, in the inlet and outlet of the impeller, the value of relative speed in the working face is same as that in the back face; while in the central section of the impeller, because of the affection of axial eddy, the value of relative speed in the back face is higher than that on the working face. Comparing with the relative speed distribution of different work conditions, it is found that, as flux grows, the relative speed also grows continuously, and the area of low-speed is becoming smaller while the velocity gradient is becoming larger. The flux has no obvious influence to the direction of relative speed. Because of the high-speed revolution of the impeller, the rotating wall brings along the liquid particle, which makes the relative motion of liquid to the rotational movement. (a)the Small Flux (b) The Design Flux (c) The Big Flux Fig.5. Relative Speed Distribution Obtained by the Numerical Simulation in Different Working Conditions. Figure 6 shows the relative velocity distribution captured. The experimental results are comparative consistent with the calculated result. But as a result of the influence of the two below factors, the value of the relative speed is disaccord between the experiment and the calculation in certain areas.

Analysis of Turbulent Flow in the Impeller of A Chemical Pump 223 1. Manufacturing inaccuracy of the impeller and the limit of the equipment condition. 2. Outlet velocity of the impeller gives an impact to the velocity in the extrudingroom while the work condition is changed, which disturbs the internal flow of the impeller. (a)the Small Flux (b) The Design Flux (c) The Big Flux Fig.6. Relative Speed Distribution Obtained by the PIV in Different Working Condition. 4.2 Pressure Isoline Distribution Figure 7 shows the pressure isoline in the impeller. Under the design work condition, the pressure distribution is more uniform. In the inlet and outlet of the impeller, the value of pressure in the working face is same as that in back face. While in the central section of the impeller, the value of pressure in the working face is higher than that in back face. With the increase of the flux, the outlet pressure becomes smaller. The value of the pressure gradually increases from the inlet to outlet and finally reaches the maximum in the outer brim of working face. Under the condition of small flux, the pressure isoline slants greatly between the vane working face and back face, and as flux increases, the gradient decreases gradually and in the flux of 1.2Q opt, the pressure isoline is almost parallel to the vane s surface, which means that with the process of the increasing flux and the decreasing pressure, the pressure between the vane working face and back face changes differently and the pressure decreases faster in back face than it is in working face. (a)the Small Flux (b) The Design Flux (c) The Big Flux Fig.7. Pressure Isolines Obtained from the Numerical Simulation in Different Working Condition.

224 Dong Liu & Min-guan Yang 4.3 Analysis of secondary flow and loss of separation Because of the diffusion of impeller channel, the boundary-layer separation happens easily. The fluid particle is subjected to the acting force right-about the pressure gradient because of the non-uniform pressure distribution. In the central section of the impeller, the acting force is in equilibrium with inertia force caused by the alteration of current velocity; While the current velocity is smaller in boundary-layer, inertia force can t equalize the acting force, which makes fluid particle in boundary-layer move to the direction right-about the pressure gradient, and the secondary flow arises with the flow direction vertical from the main flow and it also leads the loss of separation. 4.4 The loss of impaction while the work condition deviates the design condition When the work condition of the pump deviates from design condition, the fluxion angle β 1 is different from the inlet allocation angle β b1, and the flow separation in the surface of the vane and the loss of impaction in the inlet were captured in the process of PIV experiment; When the deviation became serious, many air bubbles and the vibration were found in the impeller which makes tracer particles wrongly reflect the statement of flow, as affects the result of the PIV experiment and influences the normal working of the pump as well. 4.5 The influence of the pump s performance when the vane is designed with forward attack angle Figure 5 shows that the relative velocity decreases firstly and then increases in the working face, while the relative velocity in back face has the contrary variation. Because of this phenomenon, the area of vortex in the flow passage is generated. For the improvement of pump s cavitation, while using the method of forward attack angle, the setting angle will be larger which will narrow the area of vortex in the flow passage by liquid flow, enlarge the area of flow end plane, reduce the current velocity and improve the pump s cavitation performance as well. 5. Conclusions The internal flow in the impeller of IH65 types chemical pump is numerically simulated by the CFD software FLUENT. The result of calculation is compared with the result of PIV experiment, and the state of internal flow in chemical pump is elementary analyzed. The conclusions gained are listed as follows: 1. The internal flow which is simulated in impeller is coincide with the general rule of flow in the impeller machinery, and meanwhile it also basal inosculate with the result of PIV experiment 2. When the pump operation deviates from the design condition, outlet velocity of the impeller is different from the velocity in the extruding-room and the impaction will happen, which makes the calculation different from the practical situation.

Analysis of Turbulent Flow in the Impeller of A Chemical Pump 225 3. With the process of the increasing flux and the decreasing pressure, the pressure between the vane s working face and back face changes differently and it decreases faster in back face than that in working face. 4. Because of the diffusion of impeller channel and the existence of secondary flow in the impeller, the boundary-layer separation happens and it also leads to the loss of separation. 5. The inlet setting angle can be designed as the fluid flow angle be plus with forward attack angle, which will enlarge the area of flow end plane, reduce the current velocity, relieve the crowding effect in the impeller and improve the pump s cavitation performance. 6. The analysis of numerical simulation and experiment with the medium of water in chemical pump, which will be helpful for the research of two-phase flow in the chemical pump. Acknowledgements The authors acknowledge the support received from National Natural Science Foundation of China (NO. 50476068) and " Key Lab Opening Fund of JiangSu" (NO. Cy0601). References 1. Minguan, Y., Dong, L., Can, K. (2006). Analysis of flow with salt s separation and accumulation in centrifugal pump impeller. Transactions of the Chinese Society of Agricultural Machinery, 12, 83-86. 2. Kelder, J.D.H., Dijkers, R.J.H. & van Esch, B.P.M. (2001).Experimental and theoretical study of the flow in the volute of a low specific-speed pump. Fluid Dynamics Research, 4, 267-280. 3. Mehta M., Kadambi, J.R. & Sastry, S. (2004). Study of particulate flow in the impeller of a slurry pump using PIV. Proceedings of the ASME Heat Transfer/Fluids Engineering Summer Conference. 489-499. 4. Sankovic, J.M.K. (2004). PIV investigations of the flow field in the volute of a rotary blood pump. Journal of Fluids Engineering, 5, 730-734. 5. Poroseva, S. & Iaccarino, G. (2001). Simulating separated flows using the k-ε model. Center for Turbulence Research Annual Research Briefs, 375-383. 6. Launder, B.E. and Spalding, D.B. (1974). The numerical computation of turbulent flows. Computer Methods Appl. Mech. Eng., 3(4), 269-289. 7. Adrian, R.J. (1991). Particle-imaging techniques for experimental fluid mechanics. Annual Review Fluid Mechanics, 23(3), 261-306. 8. Fernandez, J. & Santo Laria, C. (2002). A numerical analysis of a mixed flow pump. Proceeding of ASME FEDSM 02. ASME 2002 Fluids Engineering Division Summer Meeting, 791-798.