flexotherm 230V Heat pump technical specification

Similar documents
VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

PRO-CLEAN STRATIFIED TANK

XHDU Cassette type fan-coils for double/four pipe connections 1,98-14 kw HYDRONIC TERMINALS

Technical information Installation instructions

VD1 CLC. Small Valves DIN-range with a higher k v -value

Pumps type MP Motor pump combination for mounting into tanks for on/off service

Pumps type MP Motor pump combination for mounting into tanks for on/off service

TETRIS W FC NG kw

1/54 Circulation pump, safety valve, expansion vessel

HiPace 300 with TC 400, DN 100 CF-F

3 Port, 2-Ton Outdoor Heat Pump

CALYS 80P. Field pressure calibrator with high accuracy 0.01%

Air Cooler Industry AC-LN 1-7 / ACA-LN 2-7 / ACAF-LN 2-7

Solenoid valves Type EVUL

IDEA Campus Energy 2016

HiPace 1200, with TC 1200, DN 200 CF-F

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

VRF Technical Data Book

SINGLE. Technical Data Book. Big Ceiling for Europe (R410A, 50Hz, H/P) Model : AC***JNCDEH (ODU: AC***JXAD*H)

Development of high-efficiency Stirling cryocoolers for high temperature superconducting motors

WISE Damper. Active damper for Swegon s WISE System for demand-controlled ventilation QUICK FACTS

Heat Pump KEYMARK 1. AIR/WATER; BRINE/WATER; WATER/WATER HEAT PUMPS (IF APPLICABLE) 2 2. HEAT PUMPS FOR DOMESTIC HOT WATER (DHW) (IF APPLICABLE) 8

HiPace 300 with TC 110, DN 100 CF-F

Variable swirl diffusers

Electronic pressure-independent characterised control valve EPIV

SYSTEM OF ELECTRONIC PUMPS IN CASCADE Heating Air conditioning 50 Hz

THE ENERGY 68,SAVING TDVI. exible Combine Modular 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44 HP 60, 62, 64, 66 HP

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

Magnetic Property Measurement System

HiPace 300 with TC 110 and power supply pack OPS 100, DN 100 CF-F

Drive electronics pq12

Solenoid valve Types CSV 2 - CSV 22 (NC) and solenoid coil

AIR CONDITIONER (SPLIT TYPE) SERVICE MANUAL

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

NEGST. New generation of solar thermal systems. Advanced applications ENEA. Comparison of solar cooling technologies. Vincenzo Sabatelli

First tests on a solid sorption prototype for seasonal solar thermal storage.

Cambridge International Examinations Cambridge Ordinary Level

EPIV electronic pressure-independent characterised control valve EPIV

Microscopy Cryostat System

MAE 320 HW 7B. 1e. For an isolated system, please circle the parameter which will change with time. (a) Total energy;

STARPOWER IGBT GD800HTT65P4S. General Description. Features. Typical Applications SEMICONDUCTOR. Molding Type Module. 650V/800A 6 in one-package

CHAPTER 3 SHELL AND TUBE HEAT EXCHANGER

Technical guides for owner/manager of an air conditioning system: volume 8. How manufacturers could help the unfortunate energy auditor

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education

Air Handling Unit. Konvent

DS 300. Electronic Pressure Switch. with IO-Link interface. Stainless Steel Sensor. accuracy according to IEC 60770: 0.35 % FSO.

Readings for this homework assignment and upcoming lectures

Electrolysis System CHLORINSITU V (PLUS)

GRUNDFOS DATA BOOKLET MAGNA, UPE. Series 2000 circulator pumps

OASIS WIRELESS WEATHER STATION

To order, specify : Types Protection functions Current surge Asymmetry and loss of phase. Operating principle

AIR COOLED CONDENSING UNIT

Male 5/8 BSP A (mm) Dry Weight (kg) Oil Capacity (Litres) Matrix Face Area (M2) 7 ARO ARO ARO9390

Dear Sirs, MZUTL homogenizing mixers with integrated cover lifting system e.g. 200 liters

CERN, 1211 Geneva 23, Switzerland *Laboratoire des Signaux et Systèmes, UMR 8506 CNRS-Supélec, Gif-sur-Yvette, France

Multifunctional Thermostatic Circulation Valve MTCV

HiLumi LHC FP7 High Luminosity Large Hadron Collider Design Study. Milestone Report. Cryogenic Scenarios for the Cold Powering System

Supply air beam. Contact, Overview, Index. Guideline heating and cooling. Plexus. Professor / Professor Plus. Premum / Premax / Solus.

Fitting PS P - B - R2

VK2 volume flow controller Overview

AIR PREPARATION. ELECTRONICALLY CONTROLLED PRESSURE REGULATING VALVE (PROPORTIONAL PRESSURE REGULATING VALVE) SERIES control

Spring_#7. Thermodynamics. Youngsuk Nam.

2-way proportional throttle valve for block installation

CALEFFI. Modulating digital controller for heating and cooling. 161 series 01122/08 GB. replaces dp 01122/05

DS 200P. Electronic Pressure Switch. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Cooler-Bypass Thermostat Valve, Size 10

16 Appendix 16 Electrical Research Association Report

UNIVERSITY OF CAMBRIDGE INTERNATIONAL EXAMINATIONS International General Certificate of Secondary Education PHYSICS 0625/02

4 Way Reversing Valve

50/60 Hz. ecocirc XL and XLplus. high efficiency WET ROTOR circulators. ErP 2009/125/EC

4HP13 PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP WARRANTY

Variable Speed Tri-Rotor Screw Compression Technology

2/S12 DIFFUSER FOR HORIZONTAL OR VERTICAL DISCHARGE DHV. v 3.3 (en)

Week 8. Steady Flow Engineering Devices. GENESYS Laboratory

EFFICIENT 13 SEER HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Two mark questions and answers UNIT I BASIC CONCEPT AND FIRST LAW SVCET

LEAKLESS COOLING SYSTEM V.2 PRESSURE DROP CALCULATIONS AND ASSUMPTIONS

PHOS 15 LED PROJECTOR

PRESENTS SAMJIN HYDROHEAT

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Dynamic simulation of DH house stations

ABB MEASUREMENT & ANALYTICS DATA SHEET. PGC5000 Temperature programmed gas chromatograph

Rotary modules.

Variable Displacement Plug-In Motor A6VE. Series 6, for open and closed circuits Axial tapered piston, bent axis design

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Hydra Fault Current Limiting HTS Cable to be Installed in the Consolidated Edison Grid

Siv-inn School. Complete air-supply solution for school premises. Ensures excellent air supply Cleanable Reinforced front Ideal for renovation work

Pressure Measurement Single-range transmitters for general applications

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

CHAPTER 5 CONVECTIVE HEAT TRANSFER COEFFICIENT

LECTURE 6- ENERGY LOSSES IN HYDRAULIC SYSTEMS SELF EVALUATION QUESTIONS AND ANSWERS

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Circulation valves. An effective partner in the battle to prevent legionella.

GCE. Physics A. Mark Scheme for June Advanced GCE 2826/01 Unifying Concepts in Physics. Oxford Cambridge and RSA Examinations

Transcription:

flexotherm 230V Heat pump technical specification The flexotherm 230V heat pump is available in 5, 8 and 11kW models Connects to two different sources - ground or water One of the quietest heat pump ranges in the UK with Sound Safe System Green iq for the highest energy efficiency vaillantuk vaillantuk vaillantuk

flexotherm 230V technical specification Dimensions Clearances Connections 1 2 3 4 5 6 7 Connections Recessed handles and 1 cable duct 2 Heating flow 3 Heating return Heating circuit diaphragm 4 expansion tank connection 5 Hot water return Connection: From the heat 6 source to the heat pump (hot brine, A) Connection: From the heat 7 pump to the heat source (cold brine, B) Dimensions Unit 5kW Product dimensions, height (without adjustable feet) mm 1183 Product dimensions, width mm 595 8kW Product dimensions, depth mm 600 Weight, with packaging kg 161 176 188 Weight, without packaging kg 151 166 178 Weight, ready for operation kg 157 173 185 11kW

Electrical data Unit 5kW 8kW Heating circuit / compressor V/Hz 230 / 50 Auxiliary heating V/Hz 230 / 50 Power factor cos φ = 0.9 Required network impedance Zmax with inrush current limiter Ω 0.42 0.14 0.15 Fuse characteristic, type C A 20 25 32 Optional building earth leakage circuit breaker 11kW RCCB type A (type A pulse current sensitive residualcurrent circuit breakers) or RCCB type B (type B universal current sensitive residual-current circuit breakers) Inrush current (with initial current limiter) A 15 19 60 Measuring current for the compressor and electronics A 16.6 23.8 29.6 Output levels for the auxiliary electric heater kw 2.0 / 3.5 / 5.5 2.0 / 3.5 / 5.5 2.0 / 3.5 / 5.5 Minimum electrical power consumption of compressor kw 1.40 2.10 2.60 Maximum electrical power consumption of compressor kw 2.10 3.10 4.10 IP rating IP 10B Energy-related Products at 35 C band A+++* Energy-related Products at 55 C band A+++* Hydraulic connection Heating flow / return BSP male G 1½ Heat source flow / return BSP male G 1½ Central heating water expansion vessel BSP male G ¾ Heating and brine right angle connections mm 35 Heat source circuit / brine circuit Volume of the brine circuit in the heat pump l 2.5 3.1 3.6 Minimum pressure of brine fluid bar 0.7 Maximum pressure of brine fluid bar 3.0 Heating circuit / building circuit Water volume of the heating circuit in the heat pump l 3.2 3.9 4.4 Minimum pressure bar 0.7 Maximum pressure bar 3.0 Minimum flow temperature heating C 25 Maximum flow temperature heating with compressor C 65 Maximum electrical power heating circuit pump W 63 Refrigerant circuit Refrigerant type R 410 A Volume of refrigerant circuit in the heat pump kg 1.50 2.40 2.50 Global warming potential (GWP) in accordance with EU No. 517/2014 2088 CO 2 equivalent t 3132 5011 5220 Global warming potential 100 (GWP100) in accordance with EC No. 842/2006 1975 Expansion valve type Electronic Permissible pressure (relative) bar 46.0 Compressor type EVI Scroll Oil type Ester (EMKARATE RL32-3 MAF) Oil filling quantity l 0.74 1.25 1.25 *Reported efficiency when used with VRC 700 / VRC 700f controller

flexotherm 230V technical specification Ground source technical specification Heat source circuit / brine circuit Unit 5kW Minimum brine input temperature when heating C -10 Maximum brine input temperature when heating C 25 8kW Nominal flow rate ΔT 3K at B0/W35 l/h 1300 2110 2870 Minimum flow rate during continuous operation at the application l/h 1190 1990 2570 Maximum flow rate during continuous operation at the application l/h 1300 2110 2870 Maximum remaining feed head with ΔT 3K at B0/W35 bar 0.63 0.41 0.55 Electrical power for brine pump at B0/W35 ΔT 3K at 250 mbar W 49 78 80 Brine fluid type Ethylene glycol 30% volume Building circuit / heating circuit Nominal flow rate ΔT 5K l/h 930 1450 1930 Maximum remaining feed head with ΔT 5K bar 0.65 0.44 0.30 Nominal flow with ΔT 8K l/h 600 930 1290 Maximum remaining feed head with ΔT 8K bar 0.68 0.65 0.54 Minimum flow rate during continuous operation at the application l/h 600 930 1290 Maximum flow rate during continuous operation at the application l/h 930 1450 1930 Heating pump electrical power consumption for B0/W35 ΔT 3K with an external pressure loss of 250 mbar in the heating circuit W 24 37 49 Heating output B0/W35 ΔT 5K kw 5.30 8.90 11.20 Power consumption B0/W35 ΔT 5K kw 1.13 1.75 2.24 Output figure B0/W35 ΔT 5K / coefficient of performance EN 14511 4.70 5.08 5.00 Heating output B0/W45 ΔT 5K kw 5.30 8.80 11.20 Power consumption B0/W45 ΔT 5K kw 1.51 2.32 2.95 Output figure B0/W45 ΔT 5K / coefficient of performance EN 14511 3.50 3.80 3.80 Heating output B0/W55 ΔT 8K kw 5.40 9.00 11.40 Power consumption B0/W55 ΔT 8K kw 1.80 2.73 3.56 Output figure B0/W55 ΔT 8K / coefficient of performance EN 14511 3.00 3.30 3.20 Sound power level B0/W35 EN 12102/EN 14511 L WI in heating mode db(a) 43.8 45.6 48.5 11kW

Water source technical specification Heat source circuit / brine circuit Unit 5kW Heat source module 8kW VWW 11/4 SI Nominal flow of groundwater at ΔT 3K with W10/W35 l/h 1300 2160 3100 Brine fluid type Ethylene glycol 30% volume Building circuit / heating circuit Nominal flow at ΔT 5K l/h 1025 1730 2270 Maximum remaining feed head with ΔT 5K bar 0.80 2.19 4.22 Nominal flow at ΔT 8K l/h 710 1120 1510 Maximum remaining feed head with ΔT 8K bar 0.62 2.10 4.05 Minimum flow rate during continuous operation at the application l/h 710 1120 1510 Maximum flow rate during continuous operation at the application l/h 1025 1730 2270 Heating pump electrical power consumption for W10/W35 ΔT 5K with an external pressure loss of 250 mbar in the heating circuit W 24 37 49 Heating output W10/W35 ΔT 5K kw 6.40 10.00 12.90 Power consumption W10/W35 ΔT 5K kw 1.33 1.92 2.53 Output figure W10/W35 ΔT 5K / coefficient of performance EN 14511 4.80 5.20 5.10 Heating output W10/W45 ΔT 5K kw 6.30 10.10 12.90 Power consumption W10/W45 ΔT 5K kw 1.70 2.46 3.23 Output figure W10/W45 ΔT 5K / coefficient of performance EN 14511 3.70 4.10 4.00 Heating output W10/W55 ΔT 8K kw 6.30 10.30 13.30 Power consumption W10/W55 ΔT 8K kw 2.10 2.94 4.03 Output figure W10/W55 ΔT 8K / coefficient of performance EN 14511 3.00 3.50 3.30 Sound power level W10/W35 EN 12102/EN 14511 L WI in heating mode db(a) 43.3 46.9 50.0 11kW

flexotherm 230V technical specification MCS SCoP performance table flexotherm ground source heat pump 35 o C 40 o C 45 o C 50 o C 55 o C flexotherm 5kW 230V 4.67 4.15 3.64 3.50 3.36 flexotherm 8kW 230V 4.64 4.14 3.65 3.52 3.38 flexotherm 11kW 230V 4.73 4.23 3.73 3.61 3.49 flexotherm with fluocollect water source heat pump 35 o C 40 o C 45 o C 50 o C 55 o C flexotherm 5kW 230V 4.82 4.39 3.96 3.89 3.81 flexotherm 8kW 230V 5.10 4.59 4.08 3.96 3.83 flexotherm 11kW 230V 4.97 4.48 3.99 3.89 3.79 flexotherm heat pumps Description Article number flexotherm 5kW 230V 0020257358 flexotherm 8kW 230V 0020257359 flexotherm 11kW 230V 0020257360 NOTE: Article numbers include flexotherm, VR 10 sensor, right angle connection set, schematic and installation guide Accessories Description Article number fluocollect up to 11kW (water source) 0010016719 Passive cooling module up to 11kW 0010016721 flexotherm straight connection 0020212715 Brine filling station 0020106265 Glycol discharge vessel 0020145563 18 litre brine expansion vessel (5-11kW) 302097 Expansion vessel bracket 0020173592 Heat pump brine de-airer 0020261123

Controls Description Article number Wired VRC 700 control unit 0020236291 Wired VRC 700 underfloor heating control pack 0020236292 Wired VRC 700 two zone pack and DHW 0020236293 Wired VRC 700 three zone pack and DHW 0020236294 Wired VRC 700 one zone pack and solar DHW 0020236295 Wired VRC 700 two zone pack and solar DHW 0020259834 Wireless VRC 700f control unit 0020259829 Wireless VRC 700f underfloor heating control pack 0020259830 Wireless VRC 700f two zone pack and DHW 0020259831 Wireless VRC 700f three zone pack and DHW 0020259832 Wireless VRC 700f one zone pack and solar DHW 0020259833 Wireless VRC 700f two zone pack and solar DHW 0020259835 VR 70 wiring centre 0020184844 VR 71 wiring centre 0020184847 Wired VR 91 programmable room thermostat 0020171334 Wireless VR 91f programmable room thermostat 0020231566 VR 40 multifunctional module 2-in-7 0020017744 VR 32 ebus coupler 0020139895

Customer service support contact details Sales Support Vaillant products are available to purchase from reputable heating merchants in the UK. To find contact details for your nearest Vaillant sales representative: Telephone: 0345 602 0262 Renewable Service For renewable products aftersales servicing and commissioning: Telephone: 0330 100 3540 Email: aftersales@vaillant.co.uk Training Enquiries Technical Enquiries For technical assistance: Telephone: 0330 100 3540 Email: aftersales@vaillant.co.uk Vaillant provide many different training courses. For more information: Telephone: 0345 601 8885 Email: training.enquiriesuk@vaillant-group.com General Enquiries If you have a general enquiry our friendly reception staff will happily point you in the right direction: Telephone: 0345 602 2922 Vaillant Group UK Ltd Nottingham Road, Belper, Derbyshire DE56 1JT Telephone: 0345 602 2922 www.vaillant.co.uk info@vaillant.co.uk vaillantuk 09 2017 flexotherm 230V tech data sheet