Useful GC/MS Sensitivity for Improved Environmental Analyses. GC/MS Agilent Restricted

Similar documents
The Tool Box Getting More Productivity from Your GC and GC/MSD

Highly Sensitive and Rugged GC/MS/MS Tool

Identifying Pesticides with Full Scan, SIM, µecd, and FPD from a Single Injection Application

Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Workflow Using Hyphenated Mass Spectrometry Techniques

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Analysis of TO-15/TO-17 air toxics in urban air using TD GC/TOF MS and automated compound identification software

Multi-residue analysis of pesticides by GC-HRMS

Fast and Accurate EPA 8270 Quantitation Using Deconvolution

Agilent 5977A Series GC/MSD System

Improved Forensic Toxicology Screening Using A GC/MS/NPD System with a 725-Compound DRS Database. Application. Author. Introduction.

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Automated and accurate component detection using reference mass spectra

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Agilent s New 7000B Quadrupole GC/MS/MS:

Author. Abstract. Introduction

MassHunter TOF/QTOF Users Meeting

Pesticide Analysis Workflow Using Hyphenated Mass Spectrometry Techniques

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Agilent ESI and APCI sources: for polar to non-polar compounds

Enhanced Sensitivity for Biomarker Characterization in Petroleum Using Triple Quadrupole GC/MS and Backflushing

Making Sense of Differences in LCMS Data: Integrated Tools

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Finnigan LCQ Advantage MAX

Introduction to GC/MS

Expectations for GC-MS Lab

EGASUS. 4D GCxGC TOFMS. Delivering the Right Results

MassHunter Software Overview

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Agilent All Ions MS/MS

Comprehensive Pesticide Screening by GC/MSD using Deconvolution Reporting Software Application

Fast USEPA 8270 Semivolatiles Analysis Using the 6890/5973 inert GC/MSD with Performance Electronics Application

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Enhanced Simultaneous Total ion and Selective Multi-Ion GC/MS Using a Combination of New Software and Low-Bleed Columns

TIME OF FLIGHT GC/MSTOF

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note

USP<467> residual solvents

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Uncontrolled Copy. SOP-060 Chromatography, Tune Evaluation and Troubleshooting. Table of Contents. 1. Principle... 3

Translational Biomarker Core

Agilent G3212 GC-APCI Source

Agilent MassHunter Quantitative Data Analysis

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Benefits of Equipping your Lab with a Time-of-Flight Mass Spectrometer

Die Nadel im Heuhaufen

Comprehensive Pesticide Analysis in Juice Using a Combination of GC/MS and LC/MS Methods

Accurate Mass for GC/MSD & LC/MSD

STANDARD OPERATING PROCEDURES SOP: 1828 PAGE: 1 of 14 REV: 0.0 DATE: 05/12/95 ANALYSIS OF METHYL PARATHION IN CARPET SAMPLES BY GC/MS

Application Note # Performance of Method 8270 Using Hydrogen Carrier Gas on SCION Bruker SCION GC-MS

Neue Möglichkeiten zur Überwachung der Umgebungsluft mit Thermodesorption und GC/MS

Optimizing Conditions for Volatiles Analysis

The determination of residual solvents in pharmaceuticals using the Agilent G1888 headspace/6890n GC/5975 inert MSD system Application Note

Gas Chromatograph Mass Spectrometer GCMS-TQ8050 C146-E326

Applying the Agilent 5977A MSD to the Analysis of USP<467> Residual Solvents with the 7697A Headspace Sampler and 7890B GC

Screening of Pesticide Residues in Water by Sequential Stir Bar Sorptive Extraction-Thermal Desorption with GC/MS

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

Analysis of Total PCBs and PCB Congeners and Trans-nonachlor in Fish by Gas Chromatography/ Negative Chemical Ionization Single Ion Mass Spectrometry

Practical Faster GC Applications with High-Efficiency GC Columns and Method Translation Software

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Pittcon P

Cerno Application Note Extending the Limits of Mass Spectrometry

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Analyze Hydrocarbon Impurities in 1,3-Butadiene with an Agilent J&W GS-Alumina PT Column

Advantages of Reversed Sandwich Injection for Pesticide Residue Analysis

Analytical Instrumentation

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Self Cleaning Ion Source and other Innovations in Mass Spectrometry. Kirk Lokits (GCMS Applications Chemist) Blacksburg, VA February 2 nd, 2017

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

U.S. EPA Method 8270 for multicomponent analyte determination

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Application Note. Authors. Abstract. Introduction. Environmental

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Selection of a Capillary GC Column

Analysis of Pesticides in Baby Foods Using a Triple-Quadrupole GC/MS/MS

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

Signal, Noise, and Detection Limits in Mass Spectrometry

The Analysis of Trace Contaminants in High Purity Ethylene and Propylene Using GC/MS. Application. Agilent Technologies/Wasson ECE Monomer Analyzer

Agilent 6495 Triple Quadrupole LC/MS System EXPERIENCE A NEW LEVEL OF CONFIDENCE

We don t have anything against mass spectrometry. We just think it s time for a worthy alternative.

brochure brief 5973Network Mass Selective Detector General Description and Configurations

Theory and Practical Consequences.

Electron Ionization Source Parameters in GC-MS

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

The Analysis of Residual Solvents in Pharmaceutical Products Using GC-VUV and Static Headspace

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

Trim Time Not Columns Multiresidue Pesticides Analysis with an Intuvo GC/TQ

Meeting Challenging Laboratory Requirements for USEPA Method 8270 Using a Highly Sensitive, Robust, and Easy-to-Use GC/MS

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Transcription:

Useful Sensitivity for Improved Environmental Analyses Page 1

Definitions Sensitivity Analytical definition: slope of the plot of amount of analyte (x-axis) versus signal response (y-axis) Commonly used definition: minimum amount of analyte that gives an acceptable response (more correctly limit of detection ) Sensitivity Specification () S/N achieved for a very small amount of analyte injected under a carefully defined set of the instrument conditions using a matrix-free sample Useable Sensitivity Instrument and method parameters and tools that enhance the signal response and reduced noise when working with real sample matrices Page 2

Seminar Overview: Useful Sensitivity for Improved Environmental Analyses Technology Curve Where is Today? Hardware Evolution GC Capillary Flow Technologies (Backflush) MS Triple-Axis Detector, Gain Normalization and Fast Electronics for Synchronous SIM/Scan Software Evolution MS Trace Ion Detection and Deconvolution GC Retention Time Locking and New Databases Leap Promotion and Summary Literature References Page 3

Positioning of Basic Cumulative Use of Technology SIM MS Scan MS Page 4

Positioning of Newer Technologies Cumulative Use of Technology Backflush Trace Ion Detection Deconvolution Detector Splitting Synchronous SIM/Scan SIM MS Scan MS Retention Time Locking Page 5

Reasons for Slow Adoption of Technologies Unaware of the technical and/or practical benefits Too complicated; too much work to setup Not robust enough for routine use Technology imperfections that impact performance Difficult to break long standing habits Time/effort required to change established methods Constraint of government regulations Page 6

Capillary Flow Technology a proprietary Agilent Technology Photolithographic chemical milling for low dead volume Diffusion bond two halves to form a single flow plate Small, thin profile provides fast thermal response Projection welded connections for leak tight fittings Deactivation of all internal surfaces for inertness SilTite (metal) ferrules Page 7

5 th Generation Electronic Pressure Control (EPC) 7890A GC 3 rd, 4 th Generation EPC -- 0.01 psi -- Diffusion bonded plate (2D) -- one cable -- three gas connectors -- credit card size The only GC to regulat pressure to 0.001 psi The only EPC regulating pressure to 1/1000 psi 6890N GC 1 st, 2 nd Generation EPC -- 0.1 psi -- cables -- gas lines & connectors -- large size 5890 GC improved reliability and precision 5 th Generation EPC - Metal injection molded (3D) - Digital signal pathways Page 8

Backflush with QuickSwap During GC Run Split Vent Trap Aux EPC 4 psi S/S Inlet MSD 25 psi QuickSwap After GC Run Split Vent Trap Column Aux EPC 45 psi S/S Inlet MSD 1 psi Column QuickSwap performance turbo recommended Page 9

Benefits of Backflushing Shorter analysis times More samples per day per instrument Lower operating costs Longer column life Less frequent and faster GC & MSD maintenance Less chemical background Page 10

Industry Standard: Low Bleed Stationary Phases Better signal to noise, higher upper temp limit, faster run time, improved spectral purity, and greater column inertness Low bleed column DB-35ms Better detection limits S/N =10 DB-35ms, 320 C 320 C DB-35ms Primary Ion Better spectra 42 8 253 21 4 25 0 31 5 35 6 37 7 207 34 6 78 96 119 14 4 19 7 286 470 51 405 455 49 8 8.00 10.00 12.00 14.00 16.00 18.00 20.00 0 m/z--> 50 100 150 200 250 300 350 400 450 500 Standard column S/N =3 DB-35 207 253 DB-35 DB-35, 300 C 300 C 78 Primary Ion 498 31 533 1 377 8.00 10.00 12.00 14.00 16.00 18.00 20.00 CLP Pesticides Analysis 0 m/z --> 13 5 15 6 428 197 281 356 52 96 11 9 405 470 249 451 50 100 150 200 250 300 350 400 450 500 Page 11

Without Backflush: Increased Chemical Background (Spectral Noise) and Changes in Retention Time Abundance 4.6e+07 4.4e+07 4.2e+07 4e+07 3.8e+07 3.6e+07 3.4e+07 3.2e+07 3e+07 2.8e+07 2.6e+07 2.4e+07 2.2e+07 2e+07 1.8e+07 1.6e+07 1.4e+07 1.2e+07 1e+07 8000000 6000000 4000000 2000000 0 Time A: TIC: lettuce_blank.d\data.ms B: TIC: lettuce_blank3.d\data.ms Data provided by user in Almeria, Spain After only 3 samples, the background is significantly higher (increase chemical noise is every spectrum) 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 B A Overlay of two chromatograms of a blank extract injected BEFORE (A) and AFTER (B) three injections without backflush Page 12

Without Backflush: Increased Chemical Background (Spectral Noise) and Changes in Retention Time Abundance 4.6e+07 4.4e+07 4.2e+07 4e+07 3.8e+07 3.6e+07 3.4e+07 3.2e+07 3e+07 2.8e+07 2.6e+07 2.4e+07 2.2e+07 2e+07 1.8e+07 1.6e+07 1.4e+07 1.2e+07 1e+07 8000000 6000000 4000000 2000000 0 Time A: TIC: lettuce_blank.d\data.ms B: TIC: lettuce_blank3.d\data.ms Data provided by user in Almeria, Spain Increased background due to carryover of concentrated matrix 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 B A Overlay of two chromatograms of a blank extract injected BEFORE (A) and AFTER (B) three injections without backflush Page 13

With Backflush: No Increased Chemical Background (Spectral Noise) and No Change in Retention Time Abundance 4.6e+07 4.4e+07 4.2e+07 4e+07 3.8e+07 3.6e+07 3.4e+07 3.2e+07 3e+07 2.8e+07 2.6e+07 2.4e+07 2.2e+07 2e+07 1.8e+07 1.6e+07 1.4e+07 1.2e+07 1e+07 8000000 6000000 4000000 2000000 0 Time TIC: lettuce_10_ppb.d\data.ms TIC: lettuce_100_ppb.d\data.ms TIC: lettuce_5_ppb.d\data.ms Data provided by user in Almeria, Spain Stable retention times and baseline... less chemical noise 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 Overlay of three chromatograms of lettuce extract run with 2 min of back flush Page 14

Benefits of Backflushing More samples per day per instrument Longer column life Lower operating costs Less frequent and faster GC & MSD maintenance Less chemical background More consistent retention times More consistent baselines Higher quality spectra (no increase in noise during analysis sequence) Higher quality quantitation (no increase in interfering ions during analysis sequence) Page 15

Conventional Off-Axis Detector hyperbolic quartz transmission quadrupole analyzer ion beam Although not directly striking the HED- EM, excited helium neutrals can ionize other molecules and create secondary particles from collisions with surfaces (sputtered ions from surface contamination, ions from the surface, photons and electrons) high energy dynode (high voltage pulls the ions away from the neutrals) electron multiplier energetic neutrals Page 16

Triple-Axis Detector slide 1 of 3 steering rod attract the ions away from the neutrals This aperture is larger than the off-axis detector which means more ions and energetic neutrals pass to the detector ion beam Introduced 01 Feb 08 energetic neutrals Page 17

Triple-Axis Detector slide 2 of 3 shield blocking secondary ions formed by collisions with energetic neutrals in the detector region high energy dynode Introduced 01 Feb 08 energetic neutrals triple channel electron multiplier Page 18

Triple-Axis Detector slide 3 of 3 hyperbolic quartz transmission quadrupole analyzer steering rod shield for secondary particles Offset Z high energy dynode Y ion beam Introduced 01 Feb 08 X triple channel electron multiplier Page 19

Triple Channel EM Exit of the triple channels Triple channels improve signal Triple channels increase life Collector removed to show exit passages Introduced 01 Feb 08 Collector Page 20

Triple-Axis Detector: Higher Signal Lower MDL 3000 2500 2000 Increased slope = higher sensitivity 300 95% confidence limits 250 1500 200 1000 150 500 100 0 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 50 Improved detection limits! fg 0 0 100 200 300 400 500 600 700 800 900 1000 Tech Overview 5989-7655EN Page 21

New Detector for Enhanced EI Sensitivity! Abundance--> Enhanced signal hexachlorobiphenyl @ 250 fg New detector S/N-rms: 250 Standard detector S/N-rms: 35 New 1 pg OFN specification: 400:1 for turbo pumps 200:1 for diffusion pump 0 Time--> Reduced neutral noise Tech Overview 5989-7655EN Page 22

What about Chemical Noise Limited Baselines? 10-ppb standard in Jin Ying Hua extract Abundance 450000 400000 350000 300000 250000 200000 150000 100000 50000 TIC: 20071115_00012std 0.01ppm@Jinyinghua.D\datasim.ms Off-Axis TIC: 20071117_00014std 0.01ppm@Jinyinghua.D\datasim.ms Triple-Axis Larger signal SIM s/n 15.00 16.00 17.00 18.00 19.00 20.00 21.00 22.00 23.00 24.00 Time Chlorfenvinphos(Z) p,p -DDT Cyhalothrin (Gamma) Deltamethrin 318 88 201 49 318 82 248 56 Comparable S/N in complex matrices.. Why? All ions (analytes and matrix peaks) will be amplified. Triple-Axis Detector eliminates neutral noise, not matrix chemical noise But increased signal will always improve ion statistics and integration Page 23

Gain Normalized Optimization of the EM Ion source Quadrupole High Energy Dynode (10kV) i Electron Multiplier (EM) EMV EMV: 1kV to 3kV I I i GAIN Amplification of signal now, user-selectable!!! Page 24

Disadvantage of ATUNE + nv Detectors age over use: the same EMV setting will not give the same signal! 300000 New detector Signal vs EMV Aged detector 250000 200000 Sig nal 150000 Decreasing signal with age 100000 50000 Page 25 0 1000 1200 1400 1600 1800 2000 2200 2400 ATUNE+400V ATUNE (new) ATUNE (aged) ATUNE + 400V Tech Overview 5989-7654EN EMV

New Gain Normalized Methods New Aged 1000 GAIN Tune ATUNE+ n V 1000 GAIN Tune ATUNE+ n V 9.80 9.90 10.00 10.10 10.20 10.30 9.80 9.90 10.00 10.10 10.20 10.30 Consistent sensitivity over the life of the electron multiplier! Consistent sensitivity from MSD to MSD and lab to lab! Tech Overview 5989-7654EN Page 26

Using Gain Factor for Method Optimization Change (Atune + 200V) to (Atune + 400 V) How much increase? Change Gain Factor 1 to 11, a predictable x11 increase! 180k counts peak height RTIC of standard acquired at Gain Factor 1.0 Same standard reacquired with calculated Gain Factor of 11 2040k counts peak height Tech Overview 5989-7654EN Page 27

Fast Electronics Fast electronics allow SIM and Scan data in a single run SIM = maximum sensitivity for target compounds Scan = best identification of unknowns Scan data points SIM data points Chromatographic peak time Scan time SIM time more information from a single run Tech Overview 5989-3108EN Page 28

Synchronous SIM/Scan Comparison of PAHs Triphenyl phosphate Chrysene Benz[a]anthracene SIM 5.55 cycles/s Scan 45-450u 5.55 cycles/s 0.2 ppm Application 5989-4184EN Page 29

Synchronous SIM/Scan Under-sampling the peak (slow data rate) decreases area precision 6 samples/peak width for area; 8 samples/peak width for height Shorter dwell time decrease SIM S/N slightly Faster scan rates decrease scan S/N slightly Scan data points SIM data points Chromatographic peak time Scan time SIM time For many applications... the losses in precision and S/N are small compared to the gains in SIM sensitivity and scan library searches Tech Overview 5989-3108EN Page 30

Trace Ion Detection Technology Agilent proprietary algorithm Reduced noise level Improved peak shape Especially under-sampled peaks Improved library match Without Trace Ion Detection S/N = 53 Default OFF in the ChemStation With Trace Ion Detection S/N = 92 better detection at trace levels Page 31

Improve Library Match Quality Fenthion in strawberry extract Trace Ion Detection off Match Quality 30 Trace Ion Detection on Match Quality 92 Page 32

NIST AMDIS Background AMDIS: Automated Mass Spectral Deconvolution and Identification Software G. Mallard, S. Stein, O. Toropov, NIST Originally developed for detection of chemical weapons in complex mixtures (environmental samples, process streams) Designed to work without analyst input Agilent DRS Revision A.01, March 2004 AMDIS 2.64 released December 2005 (noise reduction) Agilent DRS Revision A.04, February 2008 Integrated into QEdit for qual, quant, manual integration and reports Truly a new, second generation product for deconvolution reporting Page 33

Deconvolution: Use Difference in Spectra, Retention Time and Peak Shape to Separate Coeluting Peaks Peak detected with Trace Ion Detection TIC & Spectrum Deconvoluted peaks and spectra TIC Component 1 Component 2 Component 3 matrix interference Deconvolution target Page 34

AMDIS Automatically Purifies Spectra by: True deconvolution Even if no available background for subtraction Detailed treatment of noise Complete noise analysis; used for component perception Correction for baseline drift Flat baselines not required; determines baselines for each m/z Corrects for spectral skewing in spectra Distortion generated by concentration change during scan period Extracts closely coeluting peaks Power of modern PCs and matrix mathematics Separates components that have peak apexes with a single scan Page 35

AMDIS: Pulling a Useable Spectrum Out of a Mess Analyte ions are buried in the matrix ions!! Cleaned analyte spectra are easy to match! Page 36

17 Surface Water Data Files: Pesticide Analysis Targets Found False Positives Processing Time *CDFA 37 1 ~ 8 hours Agilent DRS Same 37 + 99 additional 0 32 minutes *CDFA is the California Department of Food and Agriculture Data files courtesy of Dr. Mark Lee and Steve Siegel Save about 7.5 hours to do other jobs Page 37

Repor t - Spi nach Exampl e1c The Power of DRS: Detect the Undetected All of these compounds were missed due to chemical noise, but AMDIS detected and confirmed all five by NIST05. Hit number of the top 100 hits from 163,000+ compounds Page 38

New DRS V.04: Qual (Spectra) + Quant (Peak Area) Overlay of target(s) and Deconvoluted ion plots Target ion plot Deconvoluted ion plot Spectral review: Before AMDIS After AMDIS AMDIS Library Hits X = MSD A = AMDIS Areas & amounts from target ion and Deconvoluted ion Page 39

New DRS A.04 Report with Quantitation from both MSD ChemStation and AMDIS results GC retention time confirmation p,p -DDE target ion mismatch Lower AMDIS amount due to elimination of interferences Page 40

Summary Quant Report with both MSD Chemstation and AMDIS results partial report Page 41

Why 1/1000 psi Matters! -- Key to even better Retention Time Locking (RTL) Response 200000 190000 180000 170000 160000 150000 140000 130000 120000 110000 100000 90000 Column 1 at 1.000 psi 6.619 6.624 6.624 6.641 0.97 psi 0.963 psi 0.96 psi Agilent worries about the 3 rd decimal, so I don t have to worry about the 1 st or 2 nd decimal point - Pharma (USA) Time 80000 6.58 6.59 6.60 6.61 6.62 6.63 6.64 6.65 6.66 6.67 6.68 6.69 Page 42

Retention Time Locking Improve Confidence with Retention Time Locking Easy Quick 100 50 4.296 min. Initial run 4.72 psi Repeatable Run-to-run Operator-to-operator 0 100 50 0 4.064 min. Trim 1 meter 4.72 psi Instrument-to-instrument 100 50 4.297 min. Relock 4.42 psi 0 Page 43

Industry Specific Retention Time Locked Libraries Part Number RTL Database/Library Number of Compounds G1671AA Hazardous Chemicals 730 G1672AA Pesticide 926 G1673AA Indoor Air Toxics 171 G1674AA Forensic Toxicology 723 G1675AA Japanese Positive List Pesticide 431 G1677AA Environmental Semi-Volatile one 8270 set of 273 ; two 525 sets of 120 Library include GC method details, Getting Started manual, application notes, and HELP files Part Number RTL Database/Library Number of Compounds Free Volatile Organic Compounds 65 Free PCB Congeners 209 Free Forensic Toxicology 277 Free Fatty Acid Methyl Ester 37 Free Flavors 409 Free Organotin Derivatives Methyl, Ethyl, Pentyl modify a library to your need or create your own Page 44

Special Promotion for Capillary Flow Technologies and DRS-NIST-RTL Bundle Orders for the 5975C MSD with the Triple-Axis Detector DRS-NIST05-RTL bundle priced with a 50% discount Includes a choice of one RTL database With the standard or performance turbo only (diff pump systems excluded) Orders for the 7890A GC Selected Capillary Flow Technologies priced with a 50% discount 2-way and 3-way purged splitter and Deans switching Promotion active from February 1 until July 31, 2008 Page 45

Improve Productivity and Useable Sensitivity in Food Analysis with Agilent s 7890A/5975C D Deconvolution Reporting Software Triple-Axis Detector Trace Ion Detection Pesticide Retention Time Locked Databases Backflush and other Capillary Flow Technologies Upgrades Available for All 5975 MSDs Page 46

Thank you!!! www.agilent.com/chem... and browse our application warehouse for more related literatures Page 47

Appendix A: Literature References Page 48

References for Backflush 5989-6460EN Analysis of Suspected Flavor and Fragrance Allergens in Cosmetics Using the 7890A GC and Capillary Column Backflush (March 2007) 5989-6066EN Rapid Forensic Toxicology Screening Using an Agilent 7890A/NPD/5975C/DRS D System (Jan 2007) 5989-6095EN Direct Injection of Fish Oil for the GC-ECD Analysis of PCBs: Results Using a Dean Switch with Backflushing (Jan 2007) 5989-6018EN Improving Productivity and Extending Column Life with Backflush (Dec 2006) 5989-5111EN Simplified Backflush Using Agilent 6890 GC Post Run Command (June 2006) 5989-1716EN New Tools for Rapid Pesticide Analysis in High Matrix Samples (October 2004) Page 49

References for Fast Electronics and Synchronous SIM/Scan 5988-4188EN New Approaches to the Development of Selected Ion Monitoring Acquisition and Quantitation Methods 5989-1574EN 5973 Inert Performance Electronics: Considerations for Methods in Scan and Selected Ion Monitoring Modes 5989-5669EN Strategies for Developing Optimal Synchronous SIM- Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM 5898-3108EN Improving Productivity with Synchronous SIM/Scan 5989-4184EN Synchronous SIM/Scan Low-Level PAH Analysis Using the Agilent Technologies 6890/5975 inert D Page 50

Supporting Literature for DRS App Note 5989-7670EN, Replacing Multiple 50-Minute FPD/ELCD/SIM Analyses with One 15-Minute Full-Scan Analysis for 10x Productivity Gain (Meng/Szelewski, Nov07) Capillary flow technology for 3-way splitter Simultaneously monitor multiple detector Backflush to shorten analysis time and increase column lifetime Trace Ion Detection to reduce noise before DRS Next generation of DRS with AMDIS results in QEdit Real results from US Food and Drug Administration/Center for Food Safety and Applied Nutrition (FDA/CFSAN) Better, more accurate identification and quantification of trace compounds in complex matrices with less operator experience and time Page 51

Supporting Literature for DRS App Note 5989-7670EN, Replacing Multiple 50-Minute FPD/ELCD/SIM Analyses with One 15-Minute Full-Scan Analysis for 10x Productivity Gain (Meng/Szelewski, Nov07) Capillary flow technology for 3-way splitter Simultaneously monitor multiple detector Backflush to shorten analysis time and increase column lifetime Trace Ion Detection to reduce noise before DRS Next generation of DRS with AMDIS results in QEdit Real results from US Food and Drug Administration/Center for Food Safety and Applied Nutrition (FDA/CFSAN) Better, more accurate identification and quantification of trace compounds in complex matrices with less operator experience and time Page 52

Supporting Literature for DRS App Note 5989-7436EN, Screening for Pesticides in Food Using the Japanese Positive List Pesticide Method: Benefits of Using with Deconvolution Reporting Software and a Retention Time Locked Mass Spectral Database (Wylie, Sept07) App Note 5989-6677EN, Reducing Analysis Time Using D and Deconvolution Reporting Software (May07) App Note 5989-6066EN, Rapid Forensic Toxicology Screening Using an Agilent 7890A/NPD/5975/DRS D System (Quimby, Jan07) App Note 5989-5435EN, Screening for 171 Volatile Organic Air Pollutants Using with Deconvolution Reporting Software and a New Indoor Air Toxics Library (Wylie, Aug06) Page 53

Supporting Literature for DRS App Note 5989-5076EN, Screening for 926 Pesticides and Endocrine Disruptors by GC/Ms with Deconvolution Reporting Software and a New Pesticide Library (Wylie, Apr06) App Note 5989-4834EN, Screening for Hazardous Chemicals in Homeland Security and Environmental Samples Using a /ECD/FPD with a 731 Compound DRS Database (Quimby, Szelewski, Feb06) App Note 5989-1716EN, New Tools for Rapid Pesticide Analysis in High Matrix Samples, (Szelewski, Quimby, Oct04) App Note 5989-1654EN, A Blind Study of Pesticide Residues in Spiked and Unspiked Fruit Extracts Using Deconvolution Reporting Software App Note 5989-1157EN, Comprehensive Pesticide Screening by D using Deconvolution Reporting Software (Wylie/Szelewski/Meng, May04) Page 54