A Nonlinear Static (Pushover) Procedure Consistent with New Zealand Standards

Similar documents
INELASTIC SEISMIC DISPLACEMENT RESPONSE PREDICTION OF MDOF SYSTEMS BY EQUIVALENT LINEARIZATION

COLUMN INTERACTION EFFECT ON PUSH OVER 3D ANALYSIS OF IRREGULAR STRUCTURES

CAPACITY SPECTRUM FOR STRUCTURES ASYMMETRIC IN PLAN

Codal Provisions IS 1893 (Part 1) 2002

DETERMINATION OF PERFORMANCE POINT IN CAPACITY SPECTRUM METHOD

Nonlinear static analysis PUSHOVER

Soil-Structure Interaction in Nonlinear Pushover Analysis of Frame RC Structures: Nonhomogeneous Soil Condition

SEISMIC RESPONSE EVALUATION OF AN RC BEARING WALL BY DISPLACEMENT-BASED APPROACH

Seismic Performance of RC Building Using Spectrum Response and Pushover Analyses

3D PUSHOVER ANALYSIS: THE ISSUE OF TORSION

A Modified Response Spectrum Analysis Procedure (MRSA) to Determine the Nonlinear Seismic Demands of Tall Buildings

Seismic Assessment of a RC Building according to FEMA 356 and Eurocode 8

A PROGRESS REPORT ON ATC 55: EVALUATION AND IMPROVEMENT OF INELASTIC SEISMIC ANALYSIS PROCEDURES (FALL 2002)

1. Background. 2. Objectives of Project. Page 1 of 29

Comparison of Structural Models for Seismic Analysis of Multi-Storey Frame Buildings

A STUDY ON IMPROVEMENT OF PUSHOVER ANALYSIS

Effect of eccentric moments on seismic ratcheting of single-degree-of-freedom structures

Vertical acceleration and torsional effects on the dynamic stability and design of C-bent columns

Dynamic Analysis Using Response Spectrum Seismic Loading

Lecture 4 Dynamic Analysis of Buildings

ROSESCHOOL ANALYSIS OF CODE PROCEDURES FOR SEISMIC ASSESSMENT OF EXISTING BUILDINGS: ITALIAN SEISMIC CODE, EC8, ATC-40, FEMA356, FEMA440

TORSIONAL EFFECTS AND REGULARITY CONDITIONS IN RC BUILDINGS

Finite Element Modelling with Plastic Hinges

Assessment of Improved Nonlinear Static Procedures in FEMA-440

Pushover Seismic Analysis of Bridge Structures

Influence of Modelling Issues on Nonlinear Static Seismic Analysis of a Regular 3D Steel Structure. A. Belejo; R. Bento - Maio de

Application of Capacity Spectrum Method to timber houses considering shear deformation of horizontal frames

ESTIMATING PARK-ANG DAMAGE INDEX USING EQUIVALENT SYSTEMS

INCLUSION OF P EFFECT IN THE ESTIMATION OF HYSTERETIC ENERGY DEMAND BASED ON MODAL PUSHOVER ANALYSIS

Prof. A. Meher Prasad. Department of Civil Engineering Indian Institute of Technology Madras

QUALITATIVE COMPARISON OF STATIC PUSHOVER VERSUS INCREMENTAL DYNAMIC ANALYSIS CAPACITY CURVES

ENERGY DIAGRAM w/ HYSTERETIC

A. Belejo, R. Bento & C. Bhatt Instituto Superior Técnico, Lisbon, Portugal 1.INTRODUCTION

SEISMIC RESPONSE OF STRENGTH AND STIFFNESS DEGRADING SINGLE DEGREE OF FREEDOM SYSTEMS

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering endorsed in Earthquake Engineering

EVALUATION OF SECOND ORDER EFFECTS ON THE SEISMIC PERFORMANCE OF RC FRAMED STRUCTURES: A FRAGILITY ANALYSIS

SEISMIC RESPONSE OF SINGLE DEGREE OF FREEDOM STRUCTURAL FUSE SYSTEMS

Displacement ductility demand and strength reduction factors for rocking structures

SECANT MODES SUPERPOSITION: A SIMPLIFIED METHOD FOR SEISMIC ASSESSMENT OF RC FRAMES

CHAPTER 5. T a = 0.03 (180) 0.75 = 1.47 sec 5.12 Steel moment frame. h n = = 260 ft. T a = (260) 0.80 = 2.39 sec. Question No.

Assessment of Nonlinear Static (Pushover) Procedures Using Time-History Direct Integration Analysis

Alireza Mehdipanah BEHAVIOUR OF BUILDINGS FEATURING TRANSFER BEAMS IN THE REGIONS OF LOW TO MODERATE SEISMICITY

RESPONSE ANALYSIS STUDY OF A BASE-ISOLATED BUILDING BASED

SEISMIC BASE ISOLATION

Chord rotation demand for Effective Catenary Action under Monotonic. Loadings

BI-DIRECTIONAL SEISMIC ANALYSIS AND DESIGN OF BRIDGE STEEL TRUSS PIERS ALLOWING A CONTROLLED ROCKING RESPONSE

Modal pushover analysis for seismic vulnerability analysis

Chapter 5 Commentary STRUCTURAL ANALYSIS PROCEDURES

INFLUENCE OF EARTHQUAKE INTENSITY MEASURE ON THE PROBABILISTIC EVALUATION OF RC BUILDINGS

NUMERICAL SIMULATION OF THE INELASTIC SEISMIC RESPONSE OF RC STRUCTURES WITH ENERGY DISSIPATORS

Comparative study between the push-over analysis and the method proposed by the RPA for the evaluation of seismic reduction coefficient

Comparison of Base Shear Force Method in the Seismic Design Codes of China, America and Europe

SEISMIC PERFORMANCE OF CONCRETE COLUMNS WITH INADEQUATE TRANSVERSE REINFORCEMENT. Alistair Boys 1 Des K. Bull 2 Stefano Pampanin 3 ABSTRACT

Relevance of Fault-Normal/Parallel and Maximum Direction Rotated Ground Motions on Nonlinear Behavior of Multi-Story Buildings

Effect of Dampers on Seismic Demand of Short Period Structures

Influence of First Shape Factor in Behaviour of Rubber Bearings Base Isolated Buildings.

INELASTIC RESPONSES OF LONG BRIDGES TO ASYNCHRONOUS SEISMIC INPUTS

Coupling Beams of Shear Walls

Design of Earthquake-Resistant Structures

IMPORTANT FEATURES OF THE RESPONSE OF INELASTIC STRUCTURES TO NEAR-FIELD GROUND MOTION

SEISMIC PERFORMANCE FACTORS FOR STEEL ECCENTRICALLY BRACED FRAMES

Earthquake Loads According to IBC IBC Safety Concept

ENERGY AND DISPLACEMENT DEMANDS IMPOSED BY NEAR-SOURCE GROUND MOTIONS

Seismic performance evaluation of existing RC buildings designed as per past codes of practice

INELASTIC EARTHQUAKE RESPONSE OF BUILDINGS SUBJECTED TO TORSION

INVESTIGATION OF JACOBSEN'S EQUIVALENT VISCOUS DAMPING APPROACH AS APPLIED TO DISPLACEMENT-BASED SEISMIC DESIGN

BEHAVIOUR OF PILE SUPPORTED WHARF IN LIQUEFIED SOILS

NON-ITERATIVE EQUIVALENT LINEAR METHOD FOR DISPLACEMENT-BASED DESIGN

A modal pushover analysis procedure for estimating seismic demands for buildings

Lecture-08 Gravity Load Analysis of RC Structures

The Effect of Using Hysteresis Models (Bilinear and Modified Clough) on Seismic Demands of Single Degree of Freedom Systems

SEISMIC RELIABILITY FUNCTIONS OF MULTISTORY BUILDINGS THEIR SENSITIVITY TO SEVERAL ANALYSIS AND DESIGN VARIABLES

Evaluation of the ductility demand in partial strength steel structures in seismic areas using non-linear static analysis

on the figure. Someone has suggested that, in terms of the degrees of freedom x1 and M. Note that if you think the given 1.2

TORSIONAL IRREGULARITY IN MULTI-STORY STRUCTURES

Dynamic Stability and Design of Cantilever Bridge Columns

Inelastic Deformation Ratios for Design and Evaluation of Structures: Single-Degree-of-Freedom Bilinear Systems

ANALYSIS OF HIGHRISE BUILDING STRUCTURE WITH SETBACK SUBJECT TO EARTHQUAKE GROUND MOTIONS

Eurocode 8 Part 3: Assessment and retrofitting of buildings

PACIFIC EARTHQUAKE ENGINEERING RESEARCH CENTER

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

New Seismic Design Provisions in Japan


Inclusion of a Sacrificial Fuse to Limit Peak Base-Shear Forces During Extreme Seismic Events in Structures with Viscous Damping

Investigated in this paper is the approximation in the ATC-40 nonlinear static procedure (NSP)

STATIC NONLINEAR ANALYSIS. Advanced Earthquake Engineering CIVIL-706. Instructor: Lorenzo DIANA, PhD

[Hussain, 4(9): September 2017] ISSN DOI /zenodo Impact Factor

MODELLING DAMAGE AND PROGRESSIVE COLLAPSE OF FRAMES USING A GAUSSIAN SPRINGS BASED APPLIED ELEMENT METHOD

SHAKING TABLE COLLAPSE TESTS OF TWO SCALE MODELS OF A 4-STORY MOMENT RESISTING STEEL FRAME

Multi Linear Elastic and Plastic Link in SAP2000

PSEUDO-ENERGY RESPONSE SPECTRA FOR THE EVALUATION OF THE SEISMIC RESPONSE FROM PUSHOVER ANALYSIS

Design of Structures for Earthquake Resistance

Research Article Variability and Accuracy of Target Displacement from Nonlinear Static Procedures

Inelastic shear response of RC coupled structural walls

A Mathematical Formulation to Estimate the Fundamental Period of High-Rise Buildings Including Flexural-Shear Behavior and Structural Interaction

Lecture-09 Introduction to Earthquake Resistant Analysis & Design of RC Structures (Part I)

EVALUATION OF P-DELTA EFFECTS IN NON-DETERIORATING MDOF STRUCTURES FROM EQUIVALENT SDOF SYSTEMS

THREE-DIMENSIONAL NONLINEAR DEGRADING MODEL FOR EARTHQUAKE RESPONSE ANALYSES OF CONCRETE BRIDGES

Seismic Collapse Margin of Structures Using Modified Mode-based Global Damage Model

ΙApostolos Konstantinidis Diaphragmatic behaviour. Volume B

Transcription:

A Nonlinear Static (Pushover) Procedure Consistent with New Zealand Standards B. J. Davidson Compusoft Engineering Ltd, Auckland, New Zealand. 010 NZSEE Conference ABSTRACT: The Nonlinear Static Procedure, often used in the assessment of earthquake prone buildings is re-presented in a format consistent with current New Zealand Standards. An example demonstrates that results obtained from the proposed procedure are consistent with the intent of the Standards. 1 INTRODUCTION 1.1 Policy The 004 Building Act [1] requires Territorial Authorities to adopt policies for the assessment and possible strengthening of earthquake prone buildings. Earthquake prone buildings are non residential buildings that have a strength that is less than 33% of the strength required for a new building standard (NBS). To assist Territorial Authorities and structural engineers with the processes of assessing, evaluating and strengthening earthquake prone buildings, the NZSEE developed the guidelines, The Assessment and Improvement of the Structural Performance of Buildings in Earthquakes []. The policies adopted by Territorial Authorities usually include an initial evaluation of the building stock, followed by a more in depth investigation of the buildings that initially appear to be earthquake prone. This further investigation will typically require an analysis of the building. The NZSEE guidelines recommend the structural engineer to analyse (or assess) the building by one of a number of different methods. One of these, the Nonlinear Static Pushover (NSP) method may be used, however guidance to the use of the method is confusing as there is a number of cross references to US Standards and Guidelines. These use different nomenclature and relate to different design approaches not accepted by NZS1170.5. It is easy to surmise that the development of a criterion of %NBS using these approaches could be open to scrutiny. Following the publication of the NZSEE guidelines, research into the NSP approach has been vigorous and a number of recommendations for its modification have been made including those of Chopra [3] and Kunnath [4]. It is the intent of this paper to review the basic NSP approach, suggest modifications that make it more consistent with the intent of NZS1170.5 and draw the reader s attention to some of its shortcomings. 1. Expected 100%NBS To assess the NSP (or other) procedure it is fundamental that what is required to achieve 100%NBS is understood. A seismic design to the New Zealand Standards, NZS1170.5 [5] and NZS3101 [6], is expected to achieve a building performance consistent with the concept of capacity design. This approach suppresses brittle failure mechanisms and ensures that a 100%NBS structure not only has the required lateral strength, it has characteristics to survive events greater than the 100% design level earthquake without collapsing. In achieving this configuration, consideration of structural irregularities, accidental torsion, P-delta and higher modes is required. There are two further issues that need to be noted. Firstly, new designs to achieve 100% NBS are based upon characteristic material strengths, strengths that are less than the expected values. The consequence of this approach is that the expected strengths of new buildings are greater than their Paper Number 35

nominal 100% NBS value. Secondly, the analysis method that may be used is restricted according to the complexity of the building. For example, the Equivalent Static Method may not be used for irregular structures and the use of the Nonlinear Time History Method is restricted and may only be used by experienced analysts [1]. What appears to be an anomaly, is that as the Nonlinear Static Procedure is not referred to in NZS1170.5, consequently it is implicitly not acknowledged as an acceptable analysis procedure by the Building Code [1]. DESCRIPTION OF THE NONLINEAR STATIC PROCEDURE (NSP) Table 4. of the NZSEE guidelines provides recommendations for the analysis method that may be used for different building configurations and performance requirements. The table is reproduced below as Table 1 for reference. In essence, the elastic analysis methods, equivalent static and modal spectral response, following the FEMA [7,8] guidelines are restricted to buildings that are anticipated to have a low inelastic demand (µ < ) in addition to regularity restrictions that are similar to those required by NZS1170.5. The simplest of the inelastic methods, the SlaMA method is restricted from being used if there is significant torsional stiffness irregularity. The conclusion from referring to this table is that the Nonlinear Static Procedure (or LPA procedure) may be used for all buildings, including those with weak storeys, torsional irregularities, high ductilities etc., as long as higher modes are not influential. The procedure is relatively straight forward. A numerical model of the building is developed that includes its stiffness and strength characteristics. A solution is achieved by pushing the building with a set of lateral forces, slowly increasing their magnitude until a chosen lateral displacement is achieved. The resulting total lateral force (base shear) vs displacement plot provides a capacity curve that may then be compared with a demand curve derived from a design spectrum. The justification of this approach follows the basics of structural dynamics. Table 1. (Table 4. NZSEE)

At any time the forces acting on a building during the passage of an earthquake may be summarised as: f I () t + f D ( t) + f S ( t) = 0 Eq. 1 where f I () t = the inertia forces f D () t = the equivalent viscous damping forces, and f S () t = the internal forces. If it is assumed that as a result of an earthquake the building sways back and forward in a single shape, thus responding as a single degree of freedom (SDF), then at the position of largest displacement all parts of the structure will have no velocity. It follows that at that specific time the equivalent viscous damping forces will be zero. Eq. 1 can then be considered as an equation of static equilibrium with the introduction of f = 0. where D [ K] f = f u Eq. I S = f I are now considered as a set of externally applied lateral forces, [ K ] is the stiffness matrix for the building, and u is the resulting set of building displacements. ~ The NSP uses the solution of Eq.. It requires the shape of the lateral force vector to be chosen then applied with increasing amplitude. A comparison of Eqs. 1 and allows some of the short comings of the NSP to be highlighted. In Eq.1, the force vectors are continually changing in magnitude and shape to maintain a dynamic equilibrium with the variation in ground acceleration and the stiffness and strength changes along with the interaction of P-delta effects..1 NZSEE Guidance for the Use of NSP 1. NZSEE Section 4.3. acknowledges that the effects of higher modes cannot be captured using the NSP. ~ 3

. NZSEE Appendix 4E11.3 reproduces the guidance from FEMA 356 [8] for the lateral force distribution, that the analyses should be progressed with two different lateral force distributions; one pattern from A. (a) the UBC [9] distribution that varies the vertical distribution of lateral forces between linearly and quadratically with height depending upon the period of the first mode. (b) a distribution that follows the shape of the first mode. (c) a distribution that follows the storey shear distribution calculated from a modal response spectrum analysis that includes sufficient modes to include 90% of the mass. And another pattern from B. (a) a uniform distribution, that is the lateral forces are proportional to the mass at each level (b) an adaptive load distribution that alters to take into account the lateral deformation at each floor level. The intention is that the two force patterns should bound the solution. It should be noted here that pattern A(c) transgresses the theory of structural dynamics and conflicts with the use of the Modal Response Spectrum method as required by NZS1170.5.. Shortcomings of use of NSP The solution of Eq., at least as it is described in the NZSEE guidelines overlooks: 1. the deterioration of strength that may have occurred due cyclic displacement reversals of the building.. the possible reduction of stiffness as a result of cyclic displacement reversals of the building. 3. the influence of stiffness reduction resulting from P-delta forces, both static and dynamic. 4. although guidance is given as to different possible distributions of lateral forces, in a vertical sense, no guidance is given for possible variations of force in the horizontal direction (giving rise to different torsional demands)..3 FEMA 356 While not referred to directly as part of the NSP in the NZSEE guidelines, the Coefficient Method described in FEMA 356 [8] is available and attempts to overcome some of these shortcomings with the inclusion of empirical coefficients in the calculation of the displacement associated with demand curve. Using this approach, the demand curve is developed from, T e δ = C0C1CC3S a g Eq. 3 4π T e which modifies the elastic displacement of a SDF system, S a g with the coefficients, 4π C 0 to account for the position of the control node for where the displacement δ is calculated. C 1 to account for the variation between the response of an elasto-plastic and elastic SDF systems. C to account for the effects of a pinched hysteretic shape and stiffness and strength degradation. C 3 to account for the increased displacements resulting from dynamic P-delta effects. In this expression, S a is the pseudo spectra acceleration which is directly related to the demand base shear, and Te is the effective first mode period of the building. 4

.4 Recent Developments Criticism of the accuracy of the methods described in the NZSEE guidelines has prompted the development of a number of alternative approaches. Two of these that concentrate on obtaining a more accurate inclusion of higher mode effects are described below..4.1 The Modal Pushover Analysis (MPA) This approach developed by Goel and Chopra [10] requires a number of nonlinear static pushover analyses to be performed, each with a set of lateral forces that are proportional to the elastic modeshapes. The required roof displacement for each pushover is determined from a nonlinear time history analysis of a single degree of freedom oscillator with a period equal to the mode and a hysteretic form that is either bilinear (developed from the pushover curve) or complete (developed from a reversing pushover analysis [11]), or, alternatively, from a non linear response or design spectrum. The required structural responses, for example; hinge rotation or storey drift, are calculated from the CQC or SRSS combination from the modal pushover components. This procedure can be shown for elastic structures to be equivalent to the standard modal response spectrum analysis, while there are inherent approximations for its nonlinear application. It has been extended to better include the torsional response by using the full three dimensional modes [1]. Figure 1. (Chopra and Goel [10]) An illustration of the accuracy of the MPA procedure is presented in Fig. 1. These results from Goel and Chopra [10] for a regular nine storey frame show MPA calculated responses compared with those from NLTH analyses. The errors inherent in the calculation of storey drift ratios using the first mode, or one shape solution (as in a standard NSP) are largely reduced with the inclusion of higher modes. However the error in the calculation of the hinge rotations is large. While the magnitude of the hinge rotation higher in the building is likely to be small, and a 100% error may not be significant, it is 5

important to acknowledge the possible size of this error, as the magnitude of hinge rotation is the parameter often used to judge structural performance..4. The Adaptive Modal Combination Pushover Analysis (AMC) This approach is described by Kalkan and Kunnath [13] and has been developed to overcome the inherent weaknesses of other schemes. The AMC procedure is similar to the MPA in that a number of modal pushover analyses are required. A major difference is that the applied set of lateral forces for a specific mode is adaptive, that is it changes throughout the pushover to reflect the nonlinear behaviour of the building. Thus at step (i) of the n th modal pushover, the lateral load pattern will be s = mφ Eq.4 ( i) ( i) n n (i) where φ n is the n th modeshape found from an eigen analysis at step (i) and m is the mass matrix. To ( i) develop a modal capacity curve, the base shear V b, n is the sum of the applied forces, but the representative displacement is calculated from an energy criterion to obtain the displacement of the dynamic centre of mass. While claimed to be accurate, a criticism of the process is its complexity. 3 PROPOSED NEW ZEALAND STANDARD CONSISTENT APPROACH NZS1170.5 allows three types of analysis; Equivalent Static Method (ESM), Modal Response Spectrum (MRS) and Nonlinear Time History (NLTH). Until large scale dynamic test facilities illustrate differently, it is accepted by researchers that the NLTH approach is the benchmark for calculating the exact seismic response of a building. The variability in this approach arises from the variability in the selection and scaling of the ground motion. The NZS1170.5 procedure using a minimum of three earthquake records to achieve the design level ground motions appears to be inconsistent with common research practice where more earthquake records are used, and the mean or median result is selected as the representative structural action. This alternative approach is used in this paper. The ESM is restricted to be used in the analysis of regular buildings, however it produces different design actions than those obtained from MRS analyses which, in the author s opinion, are erroneously scaled to the base shear calculated for the ESM [16]. If we accept NZS1170.5 for what it is, to satisfy the Building Code it is important that the NSP analyses performed to determine the strength of earthquake prone buildings are consistent with the Standard. If a NSP analysis is performed following the NZSEE guidelines without cross interpretation with other New Zealand Standards this would not be achieved. Issues to be resolved 1. Which strength are we comparing the NSP analysis to? As most older buildings are likely to comply with the regularity clauses of NZS1170.5, the 100%NBS maybe calculated using a ESM or MRS approach providing a base shear as low as 80% of that calculated using the ESM. Secondly, as mentioned above, modern designs are based upon characteristic strengths, not expected strengths that are admissible in the NZSEE guidelines. This effectively means that assessed buildings are approximately 10% weaker than stated. This is an inconsistency.. How is the influence of P-delta actions included in the analysis? 3. How is torsion included in the analysis? 4. How are higher mode effects included? 5. How should stiffness and strength degradation be included? 3.1 Steps for Solution The proposed solution approach is based upon the clauses and intent of the current New Zealand Standards [5, 6] and conclusions from the research referred to in this paper. 1. Develop model allowing for gravity and sway forces to modify column strength. 6

. If any of the periods of the building are longer than two seconds [5], or the mass participating in any of the principle directions is less than 60%, a nonlinear multi mode pushover [10, 13] or NLTH approach should be used. 3. Include in the model a pinned rigid strut line through the centres of mass of each floor level to allow the total seismic weight of each floor multiplied by β/(1+βθ) to be applied. This concept is described in the Commentary of the Standard NZS1170.5. β and θ are defined in clauses 6.5.4. and 6.5. of the Standard respectively. This approach ensures that during the pushover analysis, the total applied force to the model is equal to the sum of the lateral forces plus β P /( 1+ βθ ) H where is the deflection of the building at that stage of the analysis. 4. Apply a set of forces proportionate to the first mode in the direction considered. For non symmetrical buildings, these should be applied in both the positive and negative directions at positions +/- 0.1b. The results obtained by Erduran [15] indicate that applying the lateral forces at the shifted centre of mass improves the estimation of the torsional rotation. The recommendation to use only a first mode lateral force distribution is made firstly for simplicity, but also for practicality. Many of the examples in the literature that require more than one mode to obtain an accurate solution are taller than a typical earthquake prone New Zealand building. 5. The capacity curve is plotted as the (base shear)/(seismic weight) vs the displacement of the dynamic centre of mass. As we are using a first mode approach, that is performing a single mode pushover, then to be consistent with NZS1170.5, the seismic weight should be the value that would be calculated using the ESM in design. The dynamic centre of mass can be calculated from a displaced shape of the building, the most obvious choices are the first mode shape and the shape at or near the target displacement. While different shapes will give different positions for the dynamic centre of mass, these differences are not expected to alter the outcome of the assessment. The position can be calculated as the position where the displacement of the building is the same as that of a SDF with the same period of oscillation. Thus, if φ i and mi are the shape coordinate and seismic mass at level i respectively, then the displacement required, is the displacement of the building where, φ dcom = miφi / miφi. Eq. 5 i i 6. A demand curve can be obtained by plotting the horizontal design response spectrum as described in clause 5.. of the Standard vs the target displacement. The target displacement is calculated by using the coefficient method as described in FEMA-356 [8] and ASCE -41 [16], T e δ = C0C1CC3C( T ) g Eq. 6 4π where the coefficients take the same roles in modifying the expected elastic displacement as for Eq.3. Expressions for them are redefined here to better reflect the intent of NZS1170.5. C0 will equal 1 as we plot the deflection of the dynamic centre of mass. C1 accounts for the variation between the response of an elasto-plastic and elastic SDF systems and can be obtained from clauses 5. and 7..1.1 of the Standard expressed as C 1 = µ * Sp / k µ Eq. 7 C will equal 1 as there is no account made in NZS1170.5 for differences in response of systems with a pinched hysteretic shape and stiffness and strength degradation. C3 is to account for the increased displacements resulting from dynamic P-delta effects. This can be derived from the Standard as C = 1+ βθ Eq. 8 3 7

NZS1170.5 provides limitations as to which buildings require P-delta effects included in their analyses. This is a pragmatic approach to allow simple regular buildings to be quickly designed with the knowledge that other conservative clauses in the Standard will provide for the shortfall in strength. It is recommended here, that where the NSP procedure is used in a seismic assessment procedure and the building has not been designed to modern Standards, C as per Eq.8 be included in the analysis of all buildings. 3 C (T ) is the ordinate of the elastic hazard spectrum as per clause 3.1.1 of the Standard. 7. A solution is obtained with the intersection of a suitable demand with a bilinear version of the capacity curve. It is suggested that the bilinearization should be performed as required ASCE- 41 [15]. 8. Higher Mode effects are not directly modelled which is consistent with this approach as these effects are not included in the ESM and MRS methods of analysis routinely used in modern design to NZS1170.5. It is recommended here that the additional strength to ensure an adequate performance of columns and walls due to higher modes as described in Appendix D of the Concrete Standard be implemented. It is also anticipated that hinge rotation calculated by this method is nonconservative [10]. Consequently, following the limited results presented in that reference it is recommended that the hinge rotations calculated from the NSP analysis be scaled by SF = ( 1.4 + 0.6h / H ) Eq. 9 where h is the height of the level of the hinge and H is the height of the building. 4 EXAMPLE CALCULATION AND ANALYSIS The recommendations described above are used in a pushover analysis of a regular five level, three bay, reinforced concrete building shown in Fig.. As the design and analysis of the building is described in Davidson [16], only a summary is provided here. However, it should be noted that; 1. the design did not include additional strength for P-delta effects.. that the design required that torsional effects be resisted by two transverse walls. Consequently the three dimensional nature of torsional lateral behaviour is not investigated in this example. 3. the time history analyses performed uses the expected strengths, not the lower characteristic strengths that would be used in design. The building has been designed to modern codes using the strength required from a MRS analysis based upon a structural ductility of 5, a site subsoil class of C, Z = 0.4 and N = 1. The parameters describing the building are listed in Table. For the design process, a MRS analysis was performed using SAP000 [17] scaling the design spectrum, Ch(T) by Sp / kµ to obtain a base shear of 710 kn. The design strengths of the beams were chosen as the average MRS value at each level. These values and those for the base of the columns are listed in Table 3. The initial pushover analysis was performed without P-delta effects using lateral forces applied at the floor level proportional to the product of the floor seismic weight and the X direction component of the first mode shape. This shape and the calculation to determine the dynamic centre of mass as described in Eq. 5 are listed in Table 4. The value of φ dcom, 0.07 indicates that the height of this position is between level 3 and 4, approximately 40% above level 3. The displacement of this position is plotted against the scaled base shear in Fig. 3. 8

Table Building Parameters Building Dimension Height Length (X)-Centreline Width (Y) Mass (per floor) Rot Inertia (per floor) 5 x 3.6 m 3 x 8 m 18m 330.39 (tonne) 74337 (t-m^) Beams Ixx (m^4) A' (m^) 700 x 500 0.4 x 0.0143 0.917 Columns 600 x 600 0.5 x 0.0108 0.3 Walls 4000 x 50 0.35 x 1.3333 0.8333 Concrete E (kn/m^) 7898000 Poisson ratio 0. Figure. Schematic of Basic Building 9

Table 3 Design Strengths Level Beam Strength (kn-m) 5 61 4 114 3 157 187 1 180 Col Outer 5 Col Inner 6 Table 4 Calculation of φ dcom Level Mode1 Mode1 Squared 5 0.0345 0.00119 4 0.0308 0.000949 3 0.044 0.000595 0.0158 0.0005 1 0.0063 3.97E-05 0 0 0 sum 0.1118 0.00304 φ dcom 0.07045 Demand - Capacity 0.1 0.09 mu = 4 Baseshear/Seismic Weight (kn) 0.08 0.07 0.06 0.05 0.04 0.03 0.0 0.01 mu = 5 mu = 6 0 0.03 0.05 0.1 0.113 0.15 0. 0.5 Displacement (m) Figure 3 Demand Capacity Curve in Frame Direction The demand curves for ductility levels 4, 5 and 6 as described in step 6 of the proposed procedure are also plotted. It can be seen that the capacity curve intersects with the ductility 5 demand curve at approximately a ductility of five, at the displacement 0.113 = 5 * 0.06 (the yield displacement) demonstrating the accuracy of the solution for this text book structure. Assuming that at this position no critical structural weakness has been observed, it is useful to compare hinge rotation and 10

column shear with values calculated from design level nonlinear time history analyses. Four time history analyses were performed using earthquakes scaled as required by NZS1170.5, clause 5.4. with the appropriate k1 factor. The earthquakes and the scaling factors are listed in Table 5. As the mean of the spectra of these scaled earthquakes closely follows the design spectrum, the mean of the results from the time history analyses are used here as best estimates of building responses. A comparison of the hinge rotations obtained from the pushover analysis with the calculated average maximum hinge rotations from the time history analyses is shown in Table 6. It can be seen, as predicted that the pushover values are significantly less than those calculated from the time history analyses. However, when scaled as proposed using Eq.9, an interpretation of the results from Chopra and Goel, the rotations from the two sets of analyses are a lot closer. Table 5. Earthquake used in Analyses Earthquake Motion Earthquake Year Magnitude Station Name SF (k1) Century 90 Northridge 1994 6.7 Century City LACC 1.83 Moorpark 180 " " Moorpark.06 Gillroy 00 Loma Prieta 1989 7.1 Gilroy# 1.8 Gillroy 90 " " Gilroy# 1.5 Table 6 Comparison of Hinge Rotations Level Hinge Rot (rads) Ratio Eq. 9 T/H P Over P Over Scaled (Eq.9) (1) () (3) (4) (4)/() 5 0.019 0.0067 0.0134 1.04.00 4 0.0111 0.0070 0.013 1.19 1.88 3 0.0107 0.0077 0.0136 1.7 1.76 0.0106 0.008 0.0134 1.7 1.64 1 0.0130 0.0083 0.016 0.97 1.5 Cols 0.0134 0.0077 0.0108 0.80 1.40 Table 7 compares the column shears obtained from the two sets of analyses. The greater value of shear calculated from the time history analyses emphasises the need to ensure that the dynamic amplification requirements stated in the Concrete Standard are complied with. Table 7 Column Shears Level Pushover Shear Average Max TH Shear Ratio T/H to NSP Outer Col Inner Col. Outer Col Inner Col. Outer Col Inner Col. 5 17.30 51.68 69 108 3.99.09 4 44.86 85.7 80.9 15.5 1.80 1.46 3 6.18 117.18 93.1 153.9 1.50 1.31 7.81 138.15 108 175. 1.48 1.7 1 93.53 130.53 135.3 176. 1.45 1.35 The Influence of P-Delta Figure 4 is a plot of demand-capacity curves to illustrate the influence of P-delta. Three ductility 5 demand curves are displayed. The original from Fig. 3, without the influence of P-delta, and two others with P-delta. The original capacity curve is plotted along with a second which includes the effect of P-delta. It is obvious that with P-delta acting, an intersection of demand and capacity curves is not possible. This indicates that the building has insufficient strength to resist the additional demands resulting from P-delta. A solution point can however be achieved when the seismic demands 11

are scaled by a factor of 0.77, essentially stating that this structure, designed without sufficient strength for P-delta effects, is 77%NBS. The green demand curve is for ductility 5 and includes the additional demands of P-delta. Demand - Capacity 0.1 Baseshear/Seismic Weight (kn) 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.0 0.01 Duct 5 "P delta" Duct 5 Duct 5 "P delta" SF = 0.77 0 0 0.03 0.05 0.1 0.113 0.15 0. 0.5 Displacement (m) 5 CONCLUSIONS A procedure to assess the strength of earthquake prone buildings using the NSP (static pushover) means of analysis that is consistent with current New Zealand Standards is described. In developing the procedure, inconsistencies in both the NZSEE guidelines [] and NZS1170.5 [5] have been found and suggested solutions provided. The accuracy of the proposed procedure is demonstrated through an example pushover analysis of a regular five level reinforced concrete frame. One of the features of the proposed procedure is its inclusion of P-delta effects as required by NZS1170.5. These effects are shown to be significant for the seismic performance of the frame chosen. REFERENCES: 1. NZBC, The New Zealand Building Code, 199.. NZSEE, Assessment and Improvement of the Structural Performance of Buildings in Earthquakes, June, 006. 3. Chopra, A. K. and Goel, R. K., A Modal Pushover Procedure for Estimating Seismic Demands for Buildings, Earthquake Eng. and Structural Dynamics, Vol. 31, 00. 4. Kalkan, E. and Kunnath, S. K., Adaptive Modal Combination Procedure for Nonlinear Static Analysis of Building Structures, J. Strut. Eng. ASCE, Nov. 006. 5. NZS1170.5. Structural Design Actions Part 5: Earthquake Actions New Zealand, Standards New Zealand, 004. 6. NZS3101, Concrete Structures Standard, Standards New Zealand, 006 7. ASCE, Prestandard and Commentary for the Seismic Rehabilitation of Buildings, FEMA- 73, Washington DC, 1997. 8. ASCE, Prestandard and Commentary for the Seismic Rehabilitation of Buildings, FEMA- 356, Washington DC, 000. 1

9. ASCE 7-05, Minimum Design Loads for Buildings and Other Structures, ASCE, 006. 10. Chopra, A. K. and Goel, R. K., A Modal Pushover Analysis Procedure for Estimating Seismic Demands for Buildings, Earthquake Engineering and Structural Dynamics, Vol.31, pp 561 58, 00. 11. Bodadill, H. and Chopra, A. K., Evaluation of the MPA Procedure for Estimating Seismic Demand: RC- SMRF Buildings, Earthquake Spectra, Vol. 4, No. 4 pp 87-845, Nov. 008. 1. Chopra, A. K. and Goel, R. K., A Modal Pushover Analysis Procedure to Estimate Seismic Demands for Unsymmetric - plan Buildings, Earthquake Engineering and Structural Dynamics, Vol.33, pp 903-97, 004. 13. Kalkan, E. and Kunnath, S. K., Adaptive Modal Combination Procedure for Nonlinear Static Analysis of Building Structures, ASCE, J of Struct. Eng. Pp 171-1731, Nov. 006. 14. Erduran, E., Assessment of Current Nonlinear Static Procedures on the Estimation of Torsional Effects in Low-Rise Frame Buildings, Engineering Structures, Vol. 30, pp 548-558, 008. 15. ASCE 41-06, Seismic Rehabilitation of Existing Buildings, ASCE, 007. 16. Davidson, B. J., Base Shear Scaling, Proceedings NZSEE Technical Conference, April, 008. 17. SAP000, vs 14.1, Computers and Structures Inc, Berkeley, CA., 010. 13