Real-Time Hybrid Simulation of Single and Multiple Tuned Liquid Column Dampers for Controlling Seismic-Induced Response

Similar documents
Earthquake Excited Base-Isolated Structures Protected by Tuned Liquid Column Dampers: Design Approach and Experimental Verification

DESIGN OF TLCD UNDER RANDOM LOADS: A NEW FORMULATION

Seismic Base Isolation Analysis for the Control of Structural Nonlinear Vibration

Experimental Calibration and Head Loss Prediction of Tuned Liquid Column Damper

STRUCTURAL CONTROL USING MODIFIED TUNED LIQUID DAMPERS

Semiactive Tuned Liquid Column Dampers: Experimental Study

A Bidirectional Tuned Liquid Column Damper for Reducing the Seismic Response of Buildings

The Behaviour of Simple Non-Linear Tuned Mass Dampers

Research Article A Standalone Vision Sensing System for Pseudodynamic Testing of Tuned Liquid Column Dampers

ASEISMIC DESIGN OF TALL STRUCTURES USING VARIABLE FREQUENCY PENDULUM OSCILLATOR

Vibration Control Effects of Tuned Cradle Damped Mass Damper

SIMULATION AND TESTING OF A 6-STORY STRUCTURE INCORPORATING A COUPLED TWO MASS NONLINEAR ENERGY SINK. Sean Hubbard Dept. of Aerospace Engineering

REAL-TIME HYBRID EXPERIMENTAL SIMULATION SYSTEM USING COUPLED CONTROL OF SHAKE TABLE AND HYDRAULIC ACTUATOR

A novel tuned liquid wall damper for multi-hazard mitigation

Input-Output Peak Picking Modal Identification & Output only Modal Identification and Damage Detection of Structures using

Nonlinear Analysis of Reinforced Concrete Bridges under Earthquakes

A Bidirectional Tuned Liquid Column Damper for Reducing the Seismic Response of Buildings

EXPLICIT EQUIVALENT FORCE CONTROL FOR REAL-TIME SUBSTRUCTURE TESTING

Closed form optimal solution of a tuned liquid column damper responding to earthquake

Preliminary Examination in Dynamics

Seismic response of multi-story structure with multiple tuned mass friction dampers

To Control Vibration of Cable-stayed Bridges by Semi-active Damper and Lyapunov Control Algorithm

Aseismic design of structure equipment systems using variable frequency pendulum isolator

Preliminary Examination - Dynamics

DEVELOPMENT OF A REAL-TIME HYBRID EXPERIMENTAL SYSTEM USING A SHAKING TABLE

A Sloping Surface Roller Bearing and its lateral Stiffness Measurement

Research Article Distributed Multiple Tuned Mass Dampers for Wind Vibration Response Control of High-Rise Building

Open Access Semi-active Pneumatic Devices for Control of MDOF Structures

Large-Scale Real-Time Hybrid Simulation (RTHS) of Buildings

Department of Civil Engineering, Noorul Islam University, Thucklay, India 2

Effects of Damping Ratio of Restoring force Device on Response of a Structure Resting on Sliding Supports with Restoring Force Device

International Journal of Advance Engineering and Research Development

Dr.Vinod Hosur, Professor, Civil Engg.Dept., Gogte Institute of Technology, Belgaum

DYNAMIC RESPONSE OF EARTHQUAKE EXCITED INELASTIC PRIMARY- SECONDARY SYSTEMS

THE CAPABILITY OF THE MR DAMPER VERIFIED BY SHAKING TABLE TESTS AND REAL TIME HYBRID TESTS

SHAKING TABLE DEMONSTRATION OF DYNAMIC RESPONSE OF BASE-ISOLATED BUILDINGS ***** Instructor Manual *****

751. System identification of rubber-bearing isolators based on experimental tests

A STUDY AND DEVELOPMENT OF SEMI-ACTIVE CONTROL METHOD BY MAGNETORHEOLOGICAL FLUID DAMPER IN BASE ISOLATED STRUCTURES

OPTIMAL SEISMIC PERFORMANCE OF FRICTION ENERGY DISSIPATING DEVICES

INVESTIGATION OF JACOBSEN'S EQUIVALENT VISCOUS DAMPING APPROACH AS APPLIED TO DISPLACEMENT-BASED SEISMIC DESIGN

Structural Dynamics Lecture 4. Outline of Lecture 4. Multi-Degree-of-Freedom Systems. Formulation of Equations of Motions. Undamped Eigenvibrations.

RESPONSE ANALYSIS STUDY OF A BASE-ISOLATED BUILDING BASED

Analytical and Experimental Investigations of Modified Tuned Liquid Dampers (MTLDs)

Chapter 23: Principles of Passive Vibration Control: Design of absorber

Displacement ductility demand and strength reduction factors for rocking structures

Effects of multi-directional excitations on the response of a secondary structure with two attachments

Stochastic Dynamics of SDOF Systems (cont.).

Finite Element Modules for Demonstrating Critical Concepts in Engineering Vibration Course

Fundamental study on simple quantitative approach of damping performance for semi-active damper

CONTROL OF A THREE-DIMENSIONAL STRUCTURE WITH MAGNETO-RHEOLOGICAL DAMPERS.

Self-powered and sensing control system based on MR damper: presentation and application

Tuning TMDs to Fix Floors in MDOF Shear Buildings

Comparison of base-isolated liquid storage tank models under bi-directional earthquakes

Structural Dynamics Lecture 7. Outline of Lecture 7. Multi-Degree-of-Freedom Systems (cont.) System Reduction. Vibration due to Movable Supports.

Structural Control: Introduction and Fruitful Research Areas

Software Verification

Parametric Identification of a Cable-stayed Bridge using Substructure Approach

Wire rope springs for passive vibration control of a light steel structure

Multi-level seismic damage analysis of RC framed structures. *Jianguang Yue 1)

Robust Loop Shaping Force Feedback Controller

Research Article Experimental Study on Variation Rules of Damping with Influential Factors of Tuned Liquid Column Damper

DYNAMIC RESPONSE OF ELEVATED LIQUID STORAGE ELASTIC TANKS WITH BAFFLE

1. Introduction

Response of Elastic and Inelastic Structures with Damping Systems to Near-Field and Soft-Soil Ground Motions

Seismic Analysis of Structures by TK Dutta, Civil Department, IIT Delhi, New Delhi.

Introduction to structural dynamics

Investigation of semi-active control for seismic protection of elevated highway bridges

The Dynamic Response Analysis of Concrete Gravity Dam under the Earthquake

1330. Comparative study of model updating methods using frequency response function data

HYBRID CONTROL STRATEGY FOR SEISMIC PROTECTION OF BENCHMARK CABLE-STAYE BRIDGE

IMPORTANT FEATURES OF THE RESPONSE OF INELASTIC STRUCTURES TO NEAR-FIELD GROUND MOTION

Evidence of Soil-Structure Interaction from Ambient Vibrations - Consequences on Design Spectra

NONLINEAR CHARACTERISTICS OF THE PILE-SOIL SYSTEM UNDER VERTICAL VIBRATION

Vibration Control of Building Subjected to Harmonic Excitation

Dynamics of Structures

BI-DIRECTIONAL SEISMIC ANALYSIS AND DESIGN OF BRIDGE STEEL TRUSS PIERS ALLOWING A CONTROLLED ROCKING RESPONSE

Effect of Dampers on Seismic Demand of Short Period Structures

DEVELOPMENT OF EQUIVALENT FORCE CONTROL METHOD FOR PSEUDO- DYNAMIC AND REAL-TIME SUBSTRUCTURE TESTS ABSTRACT

Experimental testing of a large 9-story structure equipped with multiple nonlinear energy sinks subjected to an impulsive loading

RESPONSE SPECTRUM METHOD FOR ESTIMATION OF PEAK FLOOR ACCELERATION DEMAND


STRUCTURAL PARAMETERS IDENTIFICATION BASED ON DIFFERENTIAL EVOLUTION AND PARTICLE SWARM OPTIMIZATION

Modified Runge-Kutta Integration Algorithm for Improved Stability and Accuracy in Real Time Hybrid Simulation

DEVELOPMENT OF A LARGE SCALE HYBRID SHAKE TABLE AND APPLICATION TO TESTING A FRICTION SLIDER ISOLATED SYSTEM

Dynamic behavior of turbine foundation considering full interaction among facility, structure and soil

Comparison between the visco-elastic dampers And Magnetorheological dampers and study the Effect of temperature on the damping properties

Response Analysis for Multi Support Earthquake Excitation

Nonlinear numerical simulation of RC frame-shear wall system

Structures with Semiactive Variable Stiffness Single/Multiple Tuned Mass Dampers

CAPACITY SPECTRUM FOR STRUCTURES ASYMMETRIC IN PLAN

INFLUENCE OF FRICTION PENDULUM SYSTEM ON THE RESPONSE OF BASE ISOLATED STRUCTURES

ADVANCES IN SHAKE TABLE CONTROL AND SUBSTRUCTURE SHAKE TABLE TESTING. Matthew Joseph James Stehman

1.1 OBJECTIVE AND CONTENTS OF THE BOOK

Codal Provisions IS 1893 (Part 1) 2002

Journal of Sound and Vibration

Stability for Bridge Cable and Cable-Deck Interaction. Dr. Maria Rosaria Marsico D.J. Wagg

REAL-TIME HYBRID TESTING USING MODEL-BASED DELAY COMPENSATION

A STUDY ON IMPROVEMENT OF PUSHOVER ANALYSIS

The Effect of Using Hysteresis Models (Bilinear and Modified Clough) on Seismic Demands of Single Degree of Freedom Systems

A Modified Response Spectrum Analysis Procedure (MRSA) to Determine the Nonlinear Seismic Demands of Tall Buildings

Transcription:

6 th International Conference on Advances in Experimental Structural Engineering 11 th International Workshop on Advanced Smart Materials and Smart Structures Technology August 1-2, 215, University of Illinois, Urbana-Champaign, United States Real-Time Hybrid Simulation of Single and Multiple Tuned Liquid Column Dampers for Controlling Seismic-Induced Response Fei Zhu 1, Jin-Ting Wang 2, Feng Jin 3, Okyay Altay 4 1 Ph.D. student, State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 184, China. E-mail: zhu-f11@mails.tsinghua.edu.cn 2 Professor, State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 184, China. E-mail: wangjt@tsinghua.edu.cn 3 Professor, State Key Laboratory of Hydroscience and Engineering, Tsinghua University, Beijing 184, China. E-mail: jinfeng@tsinghua.edu.cn 4 Research assistant, Chair of Structural Analysis and Dynamics, RWTH Aachen University, Aachen 5274, Germany. E-mail: altay@lbb.rwth-aachen.de ABSTRACT Tuned liquid column damper (TLCD) is a special type of tuned liquid damper to dissipate energy of structures subjected to dynamic loads. Due to its geometric flexibility and low prime costs, TLCD is a good alternative over other damping measurements for slender structures. In this paper, the real-time hybrid simulation (RTHS) technique is employed to investigate the dynamic behavior of structures with TLCDs attached, which intend to simultaneously suppressing single and multiple modal responses. First, the verification of RTHS is demonstrated by means of a single TLCD controlling a single degree-of-freedom shear frame, and variations of structural parameters are also considered to study their effects on control efficiency. Then, the dynamic response of a 9- story benchmark building under the control of single and multiple TLCDs is further investigated. Reduction efficiencies of TLCDs are evaluated by comparing the results with those. Results show that TLCD could play excellent performance to control seismic-induced responses. KEYWORDS: real-time hybrid simulation, tuned liquid column damper, reduction efficiency, multi-mode response 1. INTRODUCTION The structural vibration of tall and slender buildings that are subjected to wind or seismic loadings is a critical issue in civil engineering. Consequently, structural control technique is widely-used to suppress the structural vibration. Tuned liquid column damper (TLCD) is a type of passive control device that receives much attention because of its excellent absorption effect, low cost, and easy maintenance. A TLCD consists of a liquid-filled U- shaped tube container that is rigidly connected to a main structure. The frequency of the liquid in TLCD can be tuned to be to an eigenfrequency of the main structure by properly designing the geometry of the tube container. TLCD dissipates energy by combining the liquid movement, the restoring force caused by the impulse, and the damping force attributed to the inherent head loss characteristics. The original concept of controlling structural vibration via TLCD was first proposed by Sakai et al. [1]; then, it experienced a developing process from single TLCD (STLCD) to multiple TLCDs (MTLCD). Most previous studies focused on theoretical and numerical analysis to investigate characteristics of TLCD, especially the nonlinear damping effect [2-5]. Parametrical studies are also extensively carried out to examine the effect of mass ratio, structural damping and stiffness, and geometrical sizes on the vibration reduction effectiveness of TLCD [1-3, 6]. In addition, numerous small-scale shaking table tests were conducted to evaluate the TLCD performance experimentally [4, 7-8]. However, these studies exhibit the following limitations: (1) for numerical simulation, though numerous techniques have been proposed to simulate the nonlinear damping force, the exact solution of motion of liquid remains difficult to be obtained; (2) for small-scale experiments, the relation between the scale effect and the nonlinearity is an issue; and (3) for conventional shaking table test, STLCD or MTLCD experiments for multiple degree-of-freedom (MDOF) or complex structures needs high requirement of experimental setup. Given this situation, a new approach must be developed for TLCD study in a convenient manner. Real-time hybrid simulation (RTHS) is an emerging experimental technique for investigating the structural dynamic behavior by partitioning a structure into physical and numerical substructures [9]. The numerical

substructure is numerically simulated in a computer, whereas the physical substructure is tested on a shaking table. RTHS has two unique advantages: (1) full- or large-scale models can be tested; and (2) nonlinear behavior of complex structures can be investigated. At present, RTHS has been utilized for the study of nonlinear damper devices. The performance of TLD for SDOF and MDOF structures was investigated comprehensively through RTHS [1-12]. In this paper, the application of TLCD on reducing structural vibration is extensively investigated through RTHS. Section 2 illustrates the RTHS framework for the structure-tlcd system. Section 3 first verifies the accuracy of RTHS by comparing responses of a single degree-of-freedom (SDOF) steel frame-tlcd system with those obtained from conventional shaking table test; then, studies the effects of key parameters of mass ratio, structural damping ratio and structural stiffness on STLCD effectiveness. The nonlinear behaviour of the STLCD is experimentally investigated as well. Section 4 conducts RTHS investigations to compare difference of control performance of TLCD for controlling single- and multiple-modal responses. Section 5 presents the conclusions. 2. RTHS FRAMEWORK OF STRUCTURE-TLCD SYSTEM It is assumed that a STLCD is installed at the top of a shear-type SDOF structure to mitigate responses under base excitation, as shown in Fig. 2.1. The governing equations of the structure-tlcd system can be expressed as follows: x(t) c s m s k s V Orifice (or baffle) d 3 d 1 x(t) A V c s H A H m s k s y(t) V xg () t H d 2 xg () t A H = d 1d 2 A V = d 2d 3 Figure 2.1 Structure-TLCD system m s mf m1 x cs x ks x ms mf xg m c 1 m 2 y f y k (1.1) f y m1 where m s, k s, and c s are the mass, stiffness, and damping of the structure, respectively. m f = ρ wa VL 2, m 1 = ρ wa VH, m 2 = ρ wa VL 1 with L 1 = 2V + αh, L 2 = 2V+ H/α where A V and A H are the vertical and horizontal cross-sectional areas of TLCD, respectively; α = A V/A H is defined as the cross-sectional area ratio; V and H are the lengths of the liquid in the vertical and horizontal directions, respectively; ρ w is the density of the liquid in TLCD; x and y are the displacements of the structure and of the liquid in the vertical column, respectively; the upper dots in x and y represent time derivatives; denotes the ground acceleration; ξ and g are the head loss coefficient and the gravitational acceleration, respectively; cf =(1 2) w AV y denotes the liquid damping; and k f = 2ρ wa Vg is the stiffness of liquid. Then, the natural frequency of TLCD can be calculated by f f 1 2 2g L. 1 x g In RTHS, the prototype TLCD is modeled as the physical substructure and experimented in shaking table alone; while the main structure is numerically simulated in computer. The RTHS framework is displayed in Fig. 2.2. Herein, the equation of motion of structure in Eq. 1.1 can be written as m x+c x+k x = -m x -[ m ( x x ) m y] (1.2) s s s s g f g FTLCD 1 where F TLCD is the measured force at the interface between the TLCD and the structure in RTHS. In this manner, the dynamic response of the emulated system can be obtained, avoiding additional solution for the nonlinearity equation of motion of the TLCD. In this paper, the Gui-λ method (λ = 11.5), a new explicit integration algorithm proposed by Gui et al. [13], is employed to solve Eq. 1.2 in real-time. The integration time-step is selected as Δt = 1/248 s.

TLCD Physical TLCD substructure Displacement Shaking table m x+c x+k x = -m x + F Numerical substructure s s s s g TLCD Measured force FTLCD Figure 2.2 RTHS framework for TLCD experiments 3. RTHS OF SDOF STEEL FRAME-STLCD SYSTEM 3.1. Accuracy verification of RTHS system In this section, the performance of a STLCD controlling dynamic responses of a SDOF steel frame is investigated through RTHSs and conventional shaking table tests. The accuracy of the RTHS system discussed in Section 2 is verified by comparing the results obtained from the two types of experimental methods. The experimental configurations are displayed in Fig. 3.1. The SDOF steel frame, shown in Fig. 3.1, has the following structural parameters: mass m s = 198.16 kg, natural frequency f s = 1.526 Hz, and damping ratio ζ s =.5%. Correspondingly, a STLCD system, made of plexi-glass, is designed to control the response of the SDOF steel frame. This STLCD consists three small TLCDs which have absolutely the same geometrical sizes (see Table 3.1). Finally, the natural frequency of the liquid in the STLCD is 1.527 Hz which is almost exactly the same as f s; and the mass ratio for each small TLCD is μ =.79%, which results the total mass ratio of the STLCD to be μ total = 2.37%. Figure 3.1 Configurations of STLCD experiments: (a) conventional shaking table test and (b) RTHS Table 3.1 Parameters for each small TLCD in the STLCD system. H (m) V (m) d1 (m) d2 (m) d3 (m) AH (m 2 ) AV (m 2 ) ff (Hz) μ (%).111.51.734.1.734.734.734 1.527.79 (a) Acceleration (g).2.1. -.1 RTHS Conventional shaking table test (b) Acceleration (g).2.1. -.1 RTHS Conventional shaking table test -.2 5 1 15 2 25 Time (s) (c).2 Acceleration (g).1. -.1 -.2 5 1 15 2 25 3 35 4 Time (s) RTHS Conventional shaking table test -.2 5 1 15 2 25 3 35 Time (s)

Figure 3.2 Comparison of the acceleration responses between the RTHS and the conventional shaking table test using (a) Kobe, (b) El Centro and earthquakes Three ground motions, namely Kobe, El Centro, and Taft, are selected as the ground accelerations. Taken into account the movement of the liquid in STLCD and the safety of the steel frame, the peak acceleration of each ground motion is scaled to.25 g. Fig. 3.2 gives the comparison of the acceleration responses at the top of the SDOF steel frame that obtained from the RTHS and the conventional shaking table test, respectively. Good agreement between the conventional shaking table test and RTHS can be observed. Fig. 3.3 presents the quantitative peak and RMS acceleration values, as well as the error results between these two experiment methods. The peak acceleration errors for the Kobe, El Centro and Taft earthquakes are 4.44%, 1.17%, and 13.89%, respectively; the corresponding RMS acceleration errors for the Kobe, El Centro and Taft earthquakes are 6.89%, 5.56%, and 3.85%, respectively. These results demonstrate that the RTHS can capture the dynamic response of STLCD controlled system effectively. (a).3.2.1. Peak acceleration (g) RTHS Error Conventional shaking table test.94.9.82.72.53.59 1.17 13.89 4.44 Kobe El Centro Taft 1 8 6 4 2 Error (%) (b).6 RMS acceleration (g).4.2. RTHS Conventional shaking table test Error.27.29.25.26.19.18 6.89 5.56 3.85 Kobe El Centro Taft 1 8 6 4 2 Error (%) Figure 3.3 Error comparison between the RTHS and the conventional shaking table test 3.2 Parametric studies In this section, a series of RTHSs is conducted to investigate the effects of structural parameters and excitation parameters on the reduction efficiency of STLCD by exploiting the convenient adjustment of RTHS parameters. It should be noted that the dynamic responses of the pure SDOF steel frame control in this section are provided by numerical simulations solved by Gui-λ method (λ = 11.5) [13]. 3.2.1. Mass ratio Mass ratio is a crucial parameter when designing the TLCD. In this section, six values of μ (μ =.79%, 1.58%, 2.37%, 3.16%, 3.95%, and 4.74%) are considered. The case wherein μ = 2.37% is discussed in Section 3.1. Reduction efficiency (%) 1 8 6 4 2 (a) Kobe 1 8 6 4 2 (b) El Centro 1 8 6 4 2 1 2 3 4 5 6 (%) 1 2 3 4 5 6 (%) 1 2 3 4 5 6 (%) Figure 3.4 Comparison of reduction efficiency of TLCD under different mass ratios (P d: peak displacement; P a: peak acceleration; R d: RMS displacement; R a: RMS acceleration) As shown in Fig. 3.4, the RTHS results obtained with the STLCD are compared with the numerical results in the absence of TLCD. For the three ground motions, the reductions of both the peak and RMS responses (displacement and acceleration) increase with μ increasing. It is worth noting that the reduction for smaller mass ratios (i.e., no more than 3.16%) have more significant growth than those for larger mass ratios (i.e., more than 3.16%). These results imply that a large mass ratio may not correspond to an equally high reduction efficiency. Hence, a range of μ from 2% to 3% is recommended as the optimum value from a practical view. 3.2.2. Structural damping ratio

The structural damping ratio ζ s is examined in this section. Four ζ s with values of.5%, 2%, 5%, and 8% are selected to conduct the RTHSs. All of the parameters in this section are the same as those presented in Section 3.1, with the exception of ζ s. It can be seen from Fig. 3.5 that the control efficiency in both the peak and RMS responses decrease as ζ s increases. A significant decrease of reduction efficiencies occurs when ζ s ranges from.5% to 2%; after this range, the reduction efficiencies are almost unchanged. It is concluded that the performance of STLCD is more sensitive given low structural damping ratios than given high structural damping ratios. Hence, the STLCD may be effective only for structures with low damping ratios in the range of.5%-2%. Reduction efficiency (%) 1 8 6 4 2 (a) Kobe (b) El Centro 1 1 8 8 6 6 4 4 2 2 2 4 6 8 1 s (%) 2 4 6 8 1 s (%) 2 4 6 8 1 s (%) Figure 3.5 Comparison of reduction efficiency of the STLCD under different structural damping ratios 3.2.3 Structural stiffness Because of degradation effect, temperature effect or soil conditions, the stiffness reduction of structure may happen, which may induce performance variation for TLCD. Under this background, the effect of structural stiffness on the reduction efficiency of the STLCD is discussed in this section by evaluating the control performance when uncertainty in the structural stiffness exists. The variation ratios of Δk s = ± 2% for the structural stiffness are considered. Fig. 3.6 compares the corresponding performance indices of the STLCD. It is clear that the effectiveness of the STLCD strongly depends on the variation of structural stiffness and the frequency content of the excitation. Hence, when designing TLCD, the tuning ratio of TLCD should be guaranteed to ensure its performance. Reduction efficiency (%) 1 8 6 4 2 (a) Kobe (b) El Centro 1 1 8 8 6 6 4 4 2 2-2 -1 1 2 k s (%) -2-1 1 2 k s (%) -2-1 1 2 k s (%) Figure 3.6 Comparison of reduction efficiency of TLCD under variation of structural stiffness 3.2.4 Load level of the ground motion input The nonlinear behavior of TLCD is a well-known phenomenon which directly determines the performance of TLCD. Considering the maximum displacement of the STLCD, the three ground motions with peak values of.125 g,.25 g,.375 g, and.5 g are taken into account, respectively. It should be noted that the RTHSs with the peak acceleration of.25 g have been carried out in Section 3.1. Fig. 3.7 plots the comparison of reduction effectiveness of the STLCD under the three ground motions with different peak accelerations. As the peak acceleration of the input ground motion is increased from.125 g to.25 g, the reduction efficiency of the STLCD, especially for the aspect of RMS response, is improved for the three ground motions; while with the peak acceleration increasing from.25 g to.5 g, the reduction efficiency of the STLCD decreases rapidly. This observation illustrates that the performance of TLCD is amplitude-

dependent, demonstrating that the nonlinear behavior of TLCD is of significance in structural control of vibrations with high amplitudes. Reduction efficiency (%) 1 8 6 4 2 (a) Kobe (b) El Centro 1 8 6 4 2 1 8 6 4 2.1.2.3.4.5 Peak acceleration (g).1.2.3.4.5 Peak acceleration (g).1.2.3.4.5 Peak acceleration (g) Figure 3.7 Comparison of reduction of the STLCD under the three ground motions with different peak values 4. RTHS OF A 9-STORY BENCHMARK BUILDING-TLCD SYSTEM A 9-story benchmark building [14], designed for the SAC Phase II Steel Project to provide a clear basis to evaluate the efficiency of various structural control strategies, is used as the studied model. The schematic view of this building is shown in Fig. 4.1. Ohtori et al. [14] proposed a finite element model to describe this model, while Maghareh et al. [15] simplified this model to be a shear-type model system with 9 DOFs. In this study, this sheartype model is employed to simplify the numerical simulation in RTHS. In this shear-type model, the mass and stiffness matrices can be founded in paper [15]. The modal damping with damping ratio of 2% is applied. The natural frequencies of the 9-story benchmark building are.449 Hz, 1.178 Hz, 1.975 Hz, 2.737 Hz, 3.436 Hz, 4.13 Hz, 4.573 Hz, 5.332 Hz and 6.122 Hz. The total mass of the structure is 9.9 1 6 kg. Considering the bearing capability of shaking table, the mass scale is assumed as C m =1 4, while the time scale and acceleration scale are assumed to be C t = C a = 1. Under this condition, the dynamic responses obtained from experiments are exactly the same as those obtained from prototype structures. Correspondingly, two types of TLCD, named and TLCD-B, are designed to control the first two modal responses of this benchmark building. The parameters and pictures of these two types of TLCDs are shown in Table 4.1 and Fig. 4.1, respectively. Two experiment configurations are considered: (1) Configuration #1 uses one to control the first modal response, and (2) Configuration #2 uses one and three TLCD-B to control the first two modal responses. Hence, the mass ratio for these two configurations are 2.2% and 3.5%, respectively. Considering the first two order mode shapes have the maximum displacement at the top of the structure, both and TLCD-B are installed at the roof. For Configuration #2, the RTHS is carried out by setting and TLCD-B on two shaking tables. Noted that only one TLCD-B is fixed at a shaking table, and the measured force will be multiplied by 3 to obtain the corresponding feedback force for 3 TLCD-B. Figure 4.1 RTHS framework for the TLCD controlled system

Table 4.1 Parameters for TLCDs Name H (m) V (m) d1 (m) d2 (m) d3 (m) AH (m 2 ) AV (m 2 ) ff (Hz) μ (%) 1.3.15.773.18.1225.139.221.459 2.2 TLCD-B.1.12.6.177.6.18.18 1.188.43 The three ground motions used in Section 3 is reemployed to excite the structure, in which the peak acceleration is scaled to.5 g. Fig. 4.2 compares the displacement and acceleration responses in frequency domain at the top of the structure control, with control and with + TLCD-B control. Fig. 4.3 provides the comparison of reduction effectiveness. For Kobe and El Centro earthquakes, the shows excellent reduction for the displacement responses but less good reduction for the acceleration responses. This is because that the acceleration response of the second-order mode is relative strong. For Taft earthquake, the second-order mode response is mainly excited so that the efficiency of is not as well as that under Kobe and El Centro earthquakes. When both and TLCD-B are applied, it is observed that the second-order mode responses are reduced significantly, especially for the acceleration responses under Kobe and El Centro earthquakes, and both displacement and acceleration responses under Taft earthquake. Displacement amplitude (mm) Displacement amplitude (mm) Displacement amplitude (mm) 15 1 5 + TLCD-B 1 2 3 4 5 6 Freqency (Hz) 15 1 5 + TLCD-B 1 2 3 4 5 6 Freqency (Hz) 3 2 1 + TLCD-B 1 2 3 4 5 6 Freqency (Hz) (a) Kobe (b) El Centro. 1 2 3 4 5 6 Frequency (Hz) Figure 4.2 Comparison of Fourier spectrums of responses (left: displacement; right: acceleration) between the for one order mode control and + TLCD-B for two order modes control Acceleration amplitude (g) Acceleration amplitude (g) Acceleration amplitude (g).2.15.1.5.1.8.6.4.2 + TLCD-B + TLCD-B. 1 2 3 4 5 6 Frequency (Hz).15.1.5 + TLCD-B. 1 2 3 4 5 6 Frequency (Hz) (a) 1 Reduction ratio (%) 8 6 4 2 35.2 26.69 31.86 39.13 + TLCD-B 12.16 27.42 (b) 1 Reduction ratio (%) 8 6 4 2 25.23 13.36 21.28 29.79 + TLCD-B 17.28 32.1 Kobe El Centro Taft Kobe El Centro Taft Figure 4.3 Comparison of reduction for RMS responses between the (a) and + TLCD-B (b)

5. CONCLUSIONS In this paper, the RTHS is employed to investigate the performance of TLCD for controlling the seismic-induced structural responses. The TLCD is physically experimented, and the structure is assumed as the numerical substructure and analytically simulated. Comparison of the dynamic responses between the RTHS and the conventional shaking table test of the SDOF steel frame-stlcd system verifies that the RTHS could achieve satisfactory accuracy. It is found that the STLCD shows a superior performance when the mass ratio is set in the range of 2%-3% and when the structural damping ratio is lower than 2%. The uncertainty of structural stiffness changes the structural frequency which results in the performance variation of STLCDs under different earthquakes. In addition, the reduction effectiveness of the STLCD could be improved with the increase of the peak acceleration of earthquake inputs. By contrast, this effectiveness may be lost when earthquake inputs are relatively strong. For RTHSs of the 9-story benchmark building installed with TLCDs, it is concluded that using MTLCD to control multi-modal responses is an effective manner to mitigate both displacement and acceleration responses. ACKNOWLEDGEMENT This research is financially supported by the National Natural Science Foundation of China (Nos. 5117993, 9121531 and 4127416), the Specialized Research Fund for the Doctoral Program of Higher Education (No. 21321132) and Tsinghua University Initiative Scientific Research Program (No. 213189285). The authors express their sincerest gratitude for the support. REFERENCES 1. Sakai, F., Takaeda, S., Tamaki, T. (1989). Tuned liquid column damper- new type device for suppression of building vibration. Proceedings of the International Conference on High-rise Buildings. Nanjing, China. 2. Gao, H., Kwok, K.C.S, Samali, B. (1997). Optimization of tuned liquid column dampers. Engineering Structures. 19:6, 476-486. 3. Gao, H., K.C.S. Kwok, K.C.S, Samali, B. (1999). Characteristics of multiple tuned liquid column dampers in suppressing structural vibration. Engineering Structures. 21, 316-331. 4. Colwell, S., Basu, B. (28). Experimental and theoretical investigations of equivalent viscous damping of structures with TLCD for different fluids. Journal of Structural Engineering ASCE. 134:1, 154-163. 5. Matteo, A.D., Iacono, F.L., Navarra, G., Pirrotta, A. (214). Direct evaluation of the equivalent linear damping for TLCD systems in random vibration for pre-design purposes. International Journal of Non-linear Mechanics. 63, 19-3. 6. Hitchcock, A., Kwok, K.C.S., Watkins, R.D., Samali, B. (1997). Characteristics of liquid column vibration absorbers (LCVA)-I, II. Engineering Structures. 19, 126 144. 7. Matteo, A.D., Iacono, F.L., Navarra, G., Pirrotta, A. (214). Experimental validation of a direct pre-design formula for TLCD. Engineering Structures. 75, 528-538. 8. Lee, S.K. Min, K.W., Lee, H.R. (211). Parameter identification of new bidirectional tuned liquid column and sloshing dampers. Journal of Sound and Vibration. 33, 1312-1327. 9. Nakashima, M., Masaoka, N. (1999). Real-time on-line test for MDOF systems. Engineering and Structural Dynamics. 28, 393-42. 1. Lee, S.K., Park, E.C., Min, K.W., Lee, S.H., Chung, L., Park, J.H. (27). Real-time hybrid shaking table testing method for the performance evaluation of a tuned liquid damper controlling seismic response of building structures. Journal of Sound and Vibration. 32:3, 596-612. 11. Sorkhabi, A.A., Malekghasemi, H., Mercan, O. (212). Dynamic behaviou and performance evaluation of tuned liquid dampers (TLDs) using real-time hybrid simulation. Structures Congress 212, 2153-2162. 12. Gui, Y., Wang, J.T., Zhou, M.X., Zhu, F., Jin, F. (214). Real-time dynamic hybrid testing for multi-storey structures installed with tuned liquid damper. Proceedings of 6th World Conference on Structural Control and Monitoring. Barcelona, Spain. 13. Gui, Y., Wang, J.T., Jin, F., Chen, C., Zhou, M.X. (214). Development of a family of explicit algorithms for structural dynamics with unconditional stability. Nonlinear Dynamics. 77:4, 1157-117. 14. Ohtori, Y., Christenson, R.E., Spencer Jr., B.F., Dyke, S.J. (24). Benchmark Control Problems for Seismically Excited Nonlinear Buildings. Journal of Engineering Mechanics: Special Issue on Benchmark Control Problems. 13:4, 386-385. 15. Maghareh, A., Barnes, M.J., Sun, Z.X. (212). Evaluation of the 9-Story Benchmark Building Shear Model. https://nees.org/resources/413.